Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Int Heart J ; 58(3): 320-327, 2017 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-28484124

RESUMO

We conducted propensity-score matched comparisons of midterm angiographic outcomes of sirolimus (SES) versus either everolimus- (EES) or biolimus- (BES) eluting stents after placements for coronary stenosis in a daily practice environment since previous randomized trials did not demonstrate the superiority of EES and BES over SES in terms of midterm angiographic outcomes.The present study was a non-randomized, retrospective, and lesion-based study, recruiting angiographically followed-up lesions within 550 days after successful and elective SES (n = 1793), EES (n = 1303), or BES (n = 324) placement for de novo native coronary stenosis during the period from August 2004 to January 2014 at 6 institutes. The endpoint, as an angiographic surrogate marker of clinical efficacy, was the distribution of in-stent follow-up percent diameter stenosis (%DS) which comprised the percentages of 1) follow-up %DS < 20 and 2) follow-up %DS > 50. Propensityscore matched analyses were conducted to adjust 21 baselines.In 1215 baseline adjusted lesions, the endpoints in the EES group [1) 74.1%, and 2) 4.6%] were significantly different from those in the SES group [57.9%; P < 0.001, 7.2%; P = 0.006, respectively). In 307 baseline adjusted lesions, the endpoints in the BES group [1) 80.5%, 2) 2.0%] were significantly different from those in the SES group [59.3%; P < 0.001, 2) 8.1%; P = 0.001, respectively].The present study is the first to confirm the superiority of midterm angiographic outcomes after the placement of EES and BES over SES for de novo coronary stenosis in a clinical setting.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/cirurgia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Everolimo/farmacologia , Intervenção Coronária Percutânea/métodos , Sirolimo/farmacologia , Idoso , Estenose Coronária/diagnóstico , Vasos Coronários/cirurgia , Feminino , Seguimentos , Humanos , Imunossupressores/farmacologia , Masculino , Pontuação de Propensão , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 88(2): 193-200, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26423017

RESUMO

OBJECTIVES: To assess the safety and efficacy of fractional flow reserve (FFR) guided paclitaxel-coated balloon (PCB) treatment for de novo coronary artery lesions. BACKGROUND: There is limited data on PCB treatment for de novo lesions especially of major epicardial coronary arteries. METHODS: Sixty-six patients with 67 de novo lesions who underwent successful plain old balloon angioplasty (POBA) were included. If POBA-FFR was favorable (≥ 0.85), PCB was applied and if POBA-FFR was <0.85, stent implantation was preferred over PCB. RESULTS: Forty-five lesions were treated with PCB (67.2%) and 22 lesions with stents (32.8%). Dual antiplatelet therapy duration was 6 weeks. Late luminal loss with PCB was significantly less than stent (0.05 ± 0.27 mm vs. 0.40 ± 0.54 mm, P = 0.022). The baseline FFR of target lesions was 0.69 ± 0.16 in PCB and 0.60 ± 0.11 in stent group (P = 0.015), however, the FFR at 9 months was not different between groups (0.85 ± 0.08 in PCB vs. 0.85 ± 0.05 in stent group, P = 0.973). At 1 year, one myocardial infarction and one target lesion revascularization related to in-stent restenosis were detected, both in the stent group. CONCLUSION: POBA-FFR-guided PCB treatment is safe and effective for de novo coronary lesions with good anatomical and physiological patency at mid-term follow-up. © 2015 Wiley Periodicals, Inc.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Reserva Fracionada de Fluxo Miocárdico/efeitos dos fármacos , Paclitaxel/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Reestenose Coronária/etiologia , Vasos Coronários/fisiopatologia , Quimioterapia Combinada , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Paclitaxel/efeitos adversos , Inibidores da Agregação Plaquetária/administração & dosagem , Valor Preditivo dos Testes , Estudos Prospectivos , Sistema de Registros , República da Coreia , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular/efeitos dos fármacos
3.
Angiology ; 72(10): 986-993, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33982603

RESUMO

We evaluated the angiographic parameter and clinical outcomes of drug-coated balloon (DCB) to assess the optimal angiographic criteria in de novo small vessel disease (SVD). Patients (n = 424, mean age: 64.4 ± 11.2 years, men: 69.8%) at 20 sites in Korea were prospectively enrolled. The primary end point was late luminal loss (LLL) at 9-month follow-up angiography. Secondary end points included restenosis rates, target lesion failure (TLF), and DCB-related thrombosis during the 12-month follow-up period. We included 403 patients for analysis excluding 21 patients who required bailout stenting. Baseline mean reference vessel .diameter was 2.52 ± 0.39 mm and mean minimal luminal diameter (MLD) was 0.71 ± 0.40 mm. The mean MLD was 1.54 ± 0.37 mm after DCB. Late luminal loss was -0.01 ± 0.43 mm and restenosis was noted in 26 patients (12.2%). Minimal luminal diameter >1.6 mm and %diameter stenosis (DS) <45% after DCB was associated maintenance of MLD without LLL at 9-months. Multivariate analysis demonstrated that %DS at baseline and post-MLD was associated with the restenosis. During 12-month follow-up, TLF was 2.6% including 1 cardiac death, 1 myocardial infarction, and 10 ischemia-driven target lesion revascularizations. Drug-coated balloon showed a low restenosis and lower LLL despite high in-segment DS. Post-MLD and % DS may be helpful to get optimal results in de novo SVD after DCB.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Angiografia Coronária , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Paclitaxel/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Sistema de Registros , República da Coreia , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
Cardiovasc Interv Ther ; 33(3): 205-216, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28349417

RESUMO

We conducted propensity-score-matched comparisons of midterm angiographic follow-up outcomes of sirolimus- versus everolimus-eluting stents (SES, EES) after elective placements for de novo coronary stenosis in small vessels (SV) in patients with diabetes mellitus (DM), because the angiographic efficacy of EES over SES for those cohorts remained unclear. The study was a non-randomized, retrospective, lesion-based, multicenter study, examining lesions followed up angiographically within 550 days, extracted from the unified database of 6 institutes. The endpoint (binary restenosis) was defined as the percentage of subjects having >50% diameter stenosis at follow-up. Propensity-score-matched analyses were conducted in 3 different vessel-size cohorts, defined by a preprocedural reference diameter (RD) <2.10, <2.35, and <2.60 mm, yielding group sizes of n = 107, 183, and 312 baseline-adjusted lesions in each of the 2 stent arms. The frequency of binary restenosis decreased significantly with increasing vessel size, at 16.8, 12.6, and 12.2%, in the SES group. However, it remained almost the same across vessel-size groups in the EES group (8.0, 6.0, and 7.5%). The p values for the significance of the differences in binary restenosis between EES and SES in each vessel size increased with the decrease in vessel size [p = 0.002, 0.040, and 0.063 (the last still nearly significant)]. Thus, in patients with DM, EES showed increasingly superior efficacy over SES for SV stenosis as the vessel size became smaller, i.e., the risk for binary restenosis became greater.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/cirurgia , Stents Farmacológicos/efeitos adversos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/métodos , Sirolimo/administração & dosagem , Idoso , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Diabetes Mellitus/cirurgia , Angiopatias Diabéticas/cirurgia , Everolimo/efeitos adversos , Feminino , Seguimentos , Humanos , Imunossupressores/administração & dosagem , Imunossupressores/efeitos adversos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Pontuação de Propensão , Estudos Retrospectivos , Sirolimo/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA