Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 623
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Mol Cell Proteomics ; 22(12): 100677, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37949301

RESUMO

Proteins can be modified by lipids in various ways, for example, by myristoylation, palmitoylation, farnesylation, and geranylgeranylation-these processes are collectively referred to as lipidation. Current chemical proteomics using alkyne lipids has enabled the identification of lipidated protein candidates but does not identify endogenous lipidation sites and is not readily applicable to in vivo systems. Here, we introduce a proteomic methodology for global analysis of endogenous protein N-terminal myristoylation sites that combines liquid-liquid extraction of hydrophobic lipidated peptides with liquid chromatography-tandem mass spectrometry using a gradient program of acetonitrile in the high concentration range. We applied this method to explore myristoylation sites in HeLa cells and identified a total of 75 protein N-terminal myristoylation sites, which is more than the number of high-confidence myristoylated proteins identified by myristic acid analog-based chemical proteomics. Isolation of myristoylated peptides from HeLa digests prepared with different proteases enabled the identification of different myristoylated sites, extending the coverage of N-myristoylome. Finally, we analyzed in vivo myristoylation sites in mouse tissues and found that the lipidation profile is tissue-specific. This simple method (not requiring chemical labeling or affinity purification) should be a promising tool for global profiling of protein N-terminal myristoylation.


Assuntos
Proteínas , Proteômica , Humanos , Animais , Camundongos , Ácido Mirístico/química , Ácido Mirístico/metabolismo , Células HeLa , Proteínas/metabolismo , Peptídeos/metabolismo , Extração Líquido-Líquido , Processamento de Proteína Pós-Traducional
2.
Chemistry ; : e202402153, 2024 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-39004609

RESUMO

Efficient recognition and extraction of hazardous anionic pollutants from water medium is of great significance for environmental concerns, representing a challenging area of research in supramolecular chemistry. In this study, we present, for the first time, a comprehensive demonstration of the ability of chalcogen bonding (ChB) to recognize and remove the ReO4- from 100% water medium. The anion recognition ability is well elucidated through solution phase NMR and ITC studies, which clearly reveal the selective binding of ReO4- over other oxo-anions. Moreover, the selenoimidazolium scaffold effectively engages in Se•••O ChB interaction with ReO4- as confirmed by X-ray crystal structure and XPS analysis. More importantly, the binding of ReO4- with different prolongations of the σ-holes, along with Se•••Se chalcogen bonding interactions, lead to the formation of a 1D supramolecular assembly. Eventually, ChB receptor Se4Me-Br exhibits ~62% ReO4- extraction efficiency through precipitation as the extraction method. Furthermore, in efforts to enhance efficiency, a hydrophobic ChB receptor Se4Do-PF6 has been prepared, achieving an efficiency of up to ~93% at a very low concentration (~5ppm) by liquid-liquid extraction.

3.
Environ Sci Technol ; 58(6): 2998-3006, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38287223

RESUMO

Acid mine drainage (AMD) from inactive coal mines can be enriched in rare earth elements (REEs) and has gained much attention as an alternative source for these technology-critical metals. However, AMD is a relatively low-grade REE resource in which the abundance of impurities and the composition variability of the feedstock create major uncertainties for the performance of REE extraction technologies. This study sought to identify AMD feedstock variables that influence the extraction efficiency of REEs by supported liquid membranes (SLMs). SLM separation is a process involving a hydrophobic membrane embedded with an extracting solvent that facilitates the selective extraction of REE ions. The major aims were to (1) assess the effectiveness of SLM-based REE separation from several AMD samples representing a spectrum of aqueous composition, (2) determine the effects of AMD storage and holding time on extraction performance, and (3) assess the impact of AMD pretreatment (e.g., filtration and pH adjustment) on REE recovery. The results showed that relative extraction fluxes of REE correlated with AMD characteristics such as pH and major ions such as Fe, Ca, and Mn. The purity of the acid strippant product, expressed as the REE dry weight content, depended on the initial REE concentrations in the AMD source rather than the flux of individual REEs across the membrane. For AMD samples stored for 3 months prior to extraction, REE recovery by SLM separations was substantially decreased if oxidation of Fe(II) to Fe(III) was observed during sample storage. Pretreatment of AMD feedstocks by pH adjustment did not substantially improve the separation performance. Overall, this study establishes primary water quality parameters of AMD that influence the SLM separation flux and product purity. Such insights contribute to a mechanistic understanding of critical metals extractions by SLM for complex and nontraditional feedstocks such as AMD wastes.


Assuntos
Compostos Férricos , Metais Terras Raras , Mineração , Solventes , Íons
4.
Anal Bioanal Chem ; 416(7): 1679-1695, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38334794

RESUMO

Many dietary supplements claim the ability to enhance sports performance and to improve the fitness of the consumers. Occasionally, along with legal ingredients, illicit compounds may be added without being labelled, leading to unintended doping. Hence, the aim of this study was to develop an analytical method to determine a set of 12 polar (logDpH=7 from -2.0 to +0.3) compounds including diuretics, stimulants, ß2-agonists, methylxanthines, and sweeteners. Hydrophilic interaction liquid chromatography was chosen as separation strategy, coupled with tandem mass spectrometry. The instrumental method was optimized using a two-step design of experiments (DoE). Firstly, a Plackett-Burman (PB) DoE was performed to identify the more influencing variables affecting peak areas and chromatographic resolution among temperature, water percentage in the mobile phase, and flow rate, as well as type and concentration of buffers. Secondly, a D-optimal DoE was set, considering only the most significant variables from the PB-DoE results, achieving a deeper understanding of the retention mechanism. Sample processing by salt-assisted liquid-liquid extraction was studied through DoE as well, and the whole method showed recoveries in the range 40-107% and procedural precision ≤11% for all analytes. Finally, it was applied to real samples, in which the four methylxanthines and two artificial sweeteners were detected and quantified in the range of 0.02-192 mg g-1. These values were compared to the quantities declared on the DS labels, when possible. Furthermore, a sequence of MS/MS scans allowed detection of a signal in one of the samples, structurally similar to the ß2-agonist clenbuterol.


Assuntos
Quimiometria , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Diuréticos , Suplementos Nutricionais , Cromatografia Líquida de Alta Pressão , Extração em Fase Sólida
5.
Anal Bioanal Chem ; 416(20): 4543-4554, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38877147

RESUMO

Organophosphate flame retardants (OPFRs) are widely used as substitutes for traditional brominated flame retardants, necessitating a reliable and sensitive method for biomonitoring their urinary metabolites to assess human exposure. This study conducted biomonitoring of 10 metabolites of OPFRs in 152 adults and assessed their association with oxidative stress biomarkers 8-hydroxydeoxyguanosine and 8-hydroxyguanosine. Urinary metabolites of OPFRs were released via enzymatic deconjugation. The addition of sodium chloride to the urine samples increases the ionic strength, inducing a salting-out effect that reduces the solubility of these compounds, thereby facilitating their extraction with a mixture of ethyl acetate and acetonitrile. Then, the metabolites of OPFRs were quantified by ultra-high performance liquid chromatography-tandem mass spectrometry, and we validated the method for linear range, precision, matrix effect, and method detection limit. The detection limit of the metabolites of OPFRs ranged from 0.01 to 0.2 µg/L, and these metabolites were detected with high frequencies ranging from 25.0 to 98.68% in the urine samples. The concentration of bis (2-chloroethyl) phosphate was significantly higher in males than in females, with the geometric mean concentration of 0.88 µg/L for males and 0.53 µg/L for females, respectively. Spearman correlation analysis revealed weak but statistically significant positive correlations among the urinary metabolites. Bayesian kernel machine regression analysis showed a significant positive association between elevated urinary concentrations of metabolites of OPFRs and increased oxidative stress levels. Di-n-butyl phosphate was identified as the metabolite that significantly contributed to the elevated level of 8-hydroxyguanosine.


Assuntos
Monitoramento Biológico , Retardadores de Chama , Limite de Detecção , Extração Líquido-Líquido , Compostos Organofosforados , Estresse Oxidativo , Espectrometria de Massas em Tandem , Humanos , Retardadores de Chama/análise , Retardadores de Chama/metabolismo , Espectrometria de Massas em Tandem/métodos , Feminino , Masculino , Cromatografia Líquida de Alta Pressão/métodos , Adulto , Monitoramento Biológico/métodos , Compostos Organofosforados/urina , Extração Líquido-Líquido/métodos , Pessoa de Meia-Idade , Biomarcadores/urina , Adulto Jovem
6.
Chirality ; 36(6): e23682, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38807280

RESUMO

Obtaining optically pure compounds in an eco-friendly and cost-efficient manner plays an important role in human health and pharmaceutical industry. Racemic separation using multistage stereoselective liquid-liquid extraction has become one of the most practical and effective approach to access homochiral enantiomers. Currently, chiral ionic liquids (CILs) with structural designability have become a promising chiral additive and enable them as adjustable candidates for racemic separation. Herein, a high-effective stereoselective liquid-liquid extraction process composed of imidazolium cations and amino acid-derived anions as the chiral additive was established for racemic 2-cyclohexylmandelic acid (CHMA) separation. We have systematically investigated the choice of organic solvent, concentration of CIL, extraction temperature, and the pH of aqueous phase. For three-stage stereoselective extraction, the maximum enantiomeric excess (e.e.) for CHMA was reached up to 40.6%. Furthermore, the mechanism of steric effect and stereoselective capacity between the CILs and racemic CHMA was discussed and simulated. We envision that the work will facilitate the development of CILs in multistage liquid-liquid extraction and promote the large-scale production of optically pure enantiomers.

7.
Arch Toxicol ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38951190

RESUMO

Snake venoms are complex mixtures majorly composed of proteins with well-studied biological effects. However, the exploration of non-protein components, especially lipids, remains limited despite their potential for discovering bioactive molecules. This study compares three liquid-liquid lipid extraction methods for both chemical and biological analyses of Bothrops moojeni snake venom. The methods evaluated include the Bligh and Dyer method (methanol, chloroform, water), considered standard; the Acunha method, a modification of the Bligh and Dyer protocol; and the Matyash method (MTBE/methanol/water), featuring an organic phase less dense than the aqueous phase. Lipidomic analysis using liquid chromatography with high-resolution mass spectrometry (LC-HRMS) system revealed comparable values of lipid constituents' peak intensity across different extraction methods. Our results show that all methods effectively extracted a similar quantity of lipid species, yielding approximately 17-18 subclasses per method. However, the Matyash and Acunha methods exhibited notably higher proportions of biologically active lipids compared to the Bligh and Dyer method, particularly in extracting lipid species crucial for cellular structure and function, such as sphingomyelins and phosphatidylinositol-phosphate. In conclusion, when selecting a lipid extraction method, it is essential to consider the study's objectives. For a biological approach, it is crucial to evaluate not only the total quantity of extracted lipids but also their quality and biological activity. The Matyash and Acunha methods show promise in this regard, potentially offering a superior option for extracting biologically active lipids compared to the Bligh and Dyer method.

8.
Biomed Chromatogr ; 38(9): e5955, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38973552

RESUMO

Ceftriaxone (CTRX) is a commonly used cephalosporin antibiotic. It is suggested that monitoring plasma/serum concentrations is helpful for its safe use. This study aimed to develop and validate an analytical method for measuring CTRX concentrations in human serum according to International Conference on Harmonization guideline M10. Ten microliters of serum sample was purified using a salting-out assisted liquid-liquid extraction procedure with magnesium sulfate. The upper layer was then diluted threefold and analyzed using a liquid chromatography-tandem mass spectrometry-based method with a total run time of 12 min. The linear calibration curve was obtained over the concentration range 5-500 µg/ml. The within-run accuracy varied from 0.2 to 6.5%, and the precision was ≤8.0%. The between-run accuracy and precision ranged from 0.7% to 5.6% and ≤6.4%, respectively. Significant carryover was resolved by injecting four blanks after high-concentration CTRX samples. The recovery rates from spiked serum at low and high concentrations were 44.4 and 43.4%, respectively. Other factors, including selectivity, matrix effects, stability, dilution integrity and reinjection reproducibility also met the acceptance criteria. Serum concentrations in 14 samples obtained from two participants receiving 2 g/day of CTRX were successfully determined using this method.


Assuntos
Ceftriaxona , Extração Líquido-Líquido , Espectrometria de Massas em Tandem , Humanos , Extração Líquido-Líquido/métodos , Ceftriaxona/sangue , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos , Modelos Lineares , Limite de Detecção , Cromatografia Líquida/métodos
9.
Biomed Chromatogr ; 38(4): e5825, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38234085

RESUMO

Determining a drug's bioavailability and bioequivalence is important for developing and approving a drug product. The procedure supports applications for generic drug products and novel therapeutic substances, makes important decisions regarding safety and efficacy, and measures a drug's concentration in biological matrices. This study aimed to develop and validate a specific, simple, sensitive, and accurate method using liquid chromatography-tandem mass spectrometry (LC-MS) for measuring bumetanide (BUM) in human plasma. Chromatographic separation was achieved using a Hypurity C18 column (4.6 × 50 mm, 5 µm) under isocratic conditions, and LC-MS detected positive ionization acquisition modes. Protonated precursor to product ion transitions were observed at m/z 365.08 → 240.10 and 370.04 → 244.52 for BUM and internal standard, respectively. The linear range of BUM in plasma samples was 3.490-401.192 ng/mL. The inter-precision value ranged from 1.76% to 4.75%. The inter-accuracy value ranged from 96.46% to 99.95%. The method was adequately validated per the U.S. Food and Drug Administration guidelines, and the results were within permissible bounds. The Cmax and Tmax values were ~53.097 ± 13.537 ng/mL and 1.25 (0.67-5.00) h, respectively. The new approach showed satisfactory results for studying BUM in human plasma with potential use in pharmacokinetic and bioequivalence investigations.


Assuntos
Bumetanida , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Disponibilidade Biológica , Equivalência Terapêutica , Reprodutibilidade dos Testes , Cromatografia Líquida de Alta Pressão/métodos
10.
J Environ Manage ; 367: 121969, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39098073

RESUMO

This study proposes liquid-liquid extraction (LLE) for the recovery of phenolic acids from winery wastewater replacing common volatile organic compounds (VOCs) with environmentally friendly solvents. On one hand, terpenes (α-pinene and p-cymene) and terpenoids (eucalyptol and linalool) were selected as green solvents and compared to common VOCs (ethyl acetate or 1-butanol). On the other hand, gallic acid (GA), vanillic acid (VA), syringic acid (SA) and caffeic acid (CA) were selected as phenolic acids to be recovered. The extraction performance was evaluated under different operation conditions: solvent-to-feed ratio, initial concentration of phenolic acids and temperature. This work also evaluated the back-extraction whole process global recovery and solvent regeneration, by means of aqueous NaOH solution. Eucalyptol has shown the highest overall global extraction performance (21.07 % for GA, 93.21 % for VA, 78.79 % for SA, and 80.57 % for CA) and lower water solubility compared to the best performing VOC solvent (1-butanol). Therefore, eucalyptol can be a potential eco-friendly solvent to replace VOCs for sustainable phenolic acid recovery from winery wastewater. Finally, to ensure a clean water stream after the LLE, the traces of solvent were completely removed by electrooxidation with boron-doped diamond anode at a current density of 422.54 A/m2.


Assuntos
Hidroxibenzoatos , Extração Líquido-Líquido , Solventes , Águas Residuárias , Águas Residuárias/química , Extração Líquido-Líquido/métodos , Solventes/química , Hidroxibenzoatos/química , Compostos Orgânicos Voláteis/química , Vinho
11.
J Environ Manage ; 362: 121306, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38833918

RESUMO

Integrated circuits (ICs) and central processing units (CPUs), essential components of electrical and electronic equipment (EEE), are complex composite materials rich in recyclable high-value strategic and critical metals, with many in concentrations higher than in their natural ores. With gold the most valuable metal present, increase in demand for gold for EEE and its limited availability have led to a steep rise in the market price of gold, making gold recycling a high priority to meet demand. To overcome the limitations associated with conventional technologies for recycling e-waste, the use of greener technologies (ionic liquids (ILs) as leaching agents), offers greater potential for the recovery of gold from e-waste components. While previous studies have demonstrated the efficiency and feasibility of using ILs for gold recovery, these works predominantly concentrate on the extraction stage and often utilise simulated solutions, lacking the implementation of a complete process validated with real samples to effectively assess its overall effectiveness. In this work, a simulated Model Test System was used to determine the optimal leaching and extraction conditions before application to real samples. With copper being the most abundant metal in the e-waste fractions, to access the gold necessitated a two-stage pre-treatment (nitric acid leaching followed by aqua regia leaching) to ensure complete removal of copper and deliver a gold-enriched leach liquor. Gold extraction from the leach liquor was achieved by liquid-liquid extraction using Cyphos 101 (0.1 M in toluene with an O:A = 1:1, 20 °C, 150 rpm, and 15 min) and as a second process by sorption extraction with loaded resins (Amberlite XAD-7 with 300 mg of Cyphos 101/g of resins at 20 °C, 150 rpm and 3 h). In both processes, complete stripping and desorption of gold was achieved (0.5 M thiourea in 0.5 M HCl) and gold recovered, as nanoparticles of purity ≥95%, via a reduction step using a sodium borohydride solution (0.1 M NaBH4 in 0.1 M NaOH). These two hydrometallurgical processes developed can achieve overall efficiencies of ≥95% for gold recovery from real e-waste components, permit the reuse of the IL and resins up to five consecutive times, and offer a promising approach for recovery from any e-waste stream rich in gold.


Assuntos
Ouro , Líquidos Iônicos , Reciclagem , Líquidos Iônicos/química , Ouro/química , Reciclagem/métodos , Resíduo Eletrônico
12.
Molecules ; 29(9)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38731611

RESUMO

Solvents prepared from natural terpenes (menthol and thymol), as H-bond acceptors, and a series of organic acids (chain lengths of 8, 10, and 14 C atoms), as H-bond donors, were characterized and tested as reaction media for liquid-liquid extraction purposes. Due to their high hydrophobicity, they seem to be promising alternatives to conventional (nonpolar and toxic) solvents, since they possess relatively less toxic, less volatile, and consequently, more environmentally friendly characteristics. Assuming that the equilibrium is established between solvent and analyte during a ligandless procedure, it can be concluded that those nonpolar solvents can efficiently extract nonpolar analytes from the aqueous environment. Previous investigations showed a wide range of applications, including their use as solvents in extractions of metal cations, small molecules, and bioactive compounds for food and pharmaceutical applications. In this work, hydrophobic solvents based on natural terpenes, which showed chemical stability and desirable physicochemical and thermal properties, were chosen as potential reaction media in the liquid-liquid extraction (LLE) procedure for Pb(II) removal from aqueous solutions. Low viscosities and high hydrophobicities of prepared solvents were confirmed as desirable properties for their application. Extraction parameters were optimized, and chosen solvents were applied. The results showed satisfactory extraction efficiencies in simple and fast procedures, followed by low solvent consumption. The best results (98%) were obtained by the thymol-based solvent, thymol-decanoic acid (Thy-DecA) 1:1, followed by L-menthol-based solvents: menthol-octanoic acid (Men-OctA) 1:1 with 97% and menthol-decanoic acid (Men-DecA) 1:1 with 94.3% efficiency.

13.
Molecules ; 29(10)2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38792118

RESUMO

A study of the liquid-liquid extraction of ReO4- anions from hydrochloric acid solutions using the ionic liquid Aliquat 336 (QCl: trialkyl(C8-C10)methylammonium chloride) via the well-known method of slope analysis along with the determination of the process parameters is presented. This study employs CCl4, CHCl3 and C6H12 as diluents. This study was carried out at room temperature (22 ± 2) °C and an aqueous/organic volumetric ratio of unity. The ligand effect on the complexation properties of ReO4- is quantitatively assessed in different organic media. The organic extract in chloroform media is examined through 1H, 13C and 15N NMR analysis as well as the HRMS technique and UV-Vis spectroscopy in order to view the anion exchange and ligand coordination in the organic phase solution. Final conclusions are given highlighting the role of the molecular diluent in complexation processes and selectivity involving ionic liquid ligands and various metal s-, p-, d- and f-cations. ReO4- ions have shown one of the best solvent extraction behaviors compared to other ions. For instance, the Aliquat 336 derivative bearing Cl- functions shows strongly enhanced extraction as well as pronounced separation abilities towards ReO4-.

14.
Molecules ; 29(2)2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38257243

RESUMO

The misuse of growth-promoting drugs such as beta-2 agonists and steroids is a known problem in farming and sports competitions. Prior to the analysis of biological samples via liquid chromatography (LC)-mass spectrometry (MS) or gas chromatography (GC)-MS, sufficient sample preparation is required to reliably identify or determine the residues of drugs. In practice, broad screening methods are often used to save time and analyze as many compounds as possible. This review was conceptualized to analyze the literature from 2018 until October 2023 for sample preparation procedures applied to animal specimens before LC- or GC-MS analysis. The animals were either used in farming or sports. In the present review, solid phase extraction (SPE) was observed as the dominant sample clean-up technique for beta-2 agonists and steroids, followed by protein precipitation. For the extraction of beta-2 agonists, mixed-mode cation exchanger-based SPE phases were preferably applied, while for the steroids, various types of SPE materials were reported. Furthermore, dispersive SPE-based QuEChERs were utilized. Combinatory use of SPE and liquid-liquid extraction (LLE) was observed to cover further drug classes in addition to beta-2 agonists in broader screening methods.


Assuntos
Agricultura , Anestésicos Locais , Animais , Fazendas , Antiácidos , Peptídeos e Proteínas de Sinalização Intercelular , Mamíferos , Esteroides
15.
J Sci Food Agric ; 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39077990

RESUMO

Papain a protease enzyme naturally present in the Carica papaya has gained significant interest across several industries due to its unique properties and versatility. The unique structure of papain imparts the functionality that assists in elucidating how papain enzyme works and making it beneficial for a variety of purposes. This review highlights recent advancements in papain extraction techniques to enhance production efficiency to meet market demand. The extraction of papain from the Carica papaya plant offers various advantages such as cost-effectiveness, biodegradability, safety, and the ability to withstand a wide range of pH and temperature conditions. Key findings reveal that non-conventional papain extraction techniques offer significant advantages in terms of efficiency, product quality, and environmental sustainability. Furthermore, papain treatment enhances the value of final products due to its anti-bacterial, anti-oxidant, and anti-obesity properties. The ability of papain to hydrolyze a wide range of proteins across various conditions makes it a suitable protease enzyme. While the study emphasizes the advantages of papain, the study also acknowledges limitations such as the continuous research and development to optimize extraction processes which will help unlock papain's potential and meet the growing demand. © 2024 Society of Chemical Industry.

16.
J Sci Food Agric ; 104(4): 2110-2119, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-37919871

RESUMO

BACKGROUND: This study explores the use of liquid-liquid extraction with thermosensitive polymers for producing laccase (Lac) from Pleurotus sajor-caju. This process leverages liquid waste from the citrus industry, specifically pulp wash. The research delves into extractive fermentation and thermoseparation, both processes being facilitated by a polymer exhibiting a lower critical solution temperature transition. RESULTS: Key factors considered include the choice of polymer, its concentration, pH, separation temperature, and the behavior of the polymer-rich phase post-extractive fermentation concerning the lower critical solution temperature. Notably, under conditions of 45% by weight of Pluronic L-61 and pH 5.0 at 25 °C, the Lac resulted in an enhancement in the purification factor of 28.4-fold, compared with the Lac obtained directly from the fermentation process on the eighth day. There was an 83.6% recovery of the Lac enzyme in the bottom phase of the system. Additionally, the unique properties of Pluronic L-61, which can induce phase separation and also allow for thermoseparation, led to a secondary fraction (aqueous solution) of Lac with purification factor of 2.1 ± 0.1-fold (at 32 ± 0.9 °C and 30 ± 0.3 min without stirring) from the polymeric phase (top phase). Fourier-transform infrared analysis validated the separation data, particularly highlighting the α-helix content in the amide I region (1600-1700 cm-1 ). CONCLUSION: In summary, the insights from this study pave the way for broader industrial applications of these techniques, underscoring benefits like streamlined process integration, heightened selectivity, and superior separation efficacy. © 2023 Society of Chemical Industry.


Assuntos
Lacase , Pleurotus , Lacase/metabolismo , Polímeros/química , Poloxâmero , Temperatura , Fermentação , Pleurotus/metabolismo
17.
Ann Pharm Fr ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38823440

RESUMO

A sensitive and accurate LC/MS method for the determination of elbasvir (ELB) and grazoprevir (GZP) in human plasma was established using daclatasvir (DCT) as an internal standard. The analytes were separated on a Waters Spherisorb phenyl column (150mm×4.6mm ID, 5µm particle size) maintained at 40°C±2°C. Gradient elution, at a flow rate of 0.8mLmin-1, was used. The mobile phase consists of 90% of acetonitrile mixed to 10% of a 5mM ammonium formate buffer (+0.1% v/v of trimethylamine, pH was adjusted to 3.2 by formic acid) as phase A and 10% of acetonitrile mixed to 90% of the same buffer as phase B. Liquid-liquid extraction with ethyl acetate solvent was used to recuperate compounds from plasma. The method was validated over a concentration range of 2 and 100ng/mL for GZP and between 1 and 50ng/mL for ELB. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels exhibited relative standard deviations (RSD)<15%, and the accuracy values ranged from 94.2 to 107.8%. The robustness of the method was established using a two-level full factorial design.

18.
Small ; 19(9): e2204512, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36538723

RESUMO

In the current drug discovery process, the synthesis of compound libraries is separated from biological screenings both conceptually and technologically. One of the reasons is that parallel on-chip high-throughput purification of synthesized compounds is still a major challenge. Here, on-chip miniaturized high-throughput liquid-liquid extraction in volumes down to 150 nL with efficiency comparable to or better than large-scale extraction utilizing separation funnels is demonstrated. The method is based on automated and programmable merging of arrays of aqueous nanoliter droplets with organic droplets. Multi-step extraction performed simultaneously or with changing conditions as well as handling of femtomoles of compounds are demonstrated. In addition, the extraction efficiency is analyzed with a fast optical readout as well as matrix-assisted laser desorption ionization-mass spectrometry on-chip detection. The new massively parallel and miniaturized purification method adds another important tool to the chemBIOS concept combining chemical combinatorial synthesis with biological screenings on the same miniaturized droplet microarray platform, which will be essential to accelerate drug discovery.


Assuntos
Descoberta de Drogas , Água , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Análise de Sequência com Séries de Oligonucleotídeos
19.
Chem Rec ; 23(8): e202200269, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36638263

RESUMO

Plastics are wonderful materials that have modernized our daily life; however, importance of effective recycling of plastics is gradually recognized widely. In this account, we describe our discovery of new and efficient methods for the chemical recycling of plastics using ionic liquids (ILs). Since the chemical recycling usually requires high temperature conditions to breakdown chemical bonds in polymeric materials, we thought that less-flammability and non-volatility of ionic liquids are the most suitable physical properties for this purpose. Ionic liquids successfully depolymerized polyamides and unsaturated polyesters smoothly and corresponding monomeric materials were obtained in good yields. To the best of our knowledge, this was the first use of Ionic liquids for such reactions. However, we encountered another difficult problem-separation. To solve the problem, we developed solubility-switchable ionic liquids, a new type of ionic liquids in which solubility is readily changed using the chemistry of protective groups. Conversion between hydrophilic and lipophilic forms was readily achieved using a simple chemical treatment under mild conditions, and the complete separation of products was achieved by liquid-liquid-extraction. The robustness of either form unlocks their wide use as reaction solvents.

20.
Clin Chem Lab Med ; 61(3): 452-463, 2023 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-36537103

RESUMO

OBJECTIVES: Conventionally, reference intervals are established by direct methods, which require a well-characterized, obviously healthy study population. This elaborate approach is time consuming, costly and has rarely been applied to steroid hormones measured by mass spectrometry. In this feasibility study, we investigate whether indirect methods based on routine laboratory results can be used to verify reference intervals from external sources. METHODS: A total of 11,259 serum samples were used to quantify 13 steroid hormones by mass spectrometry. For indirect estimation of reference intervals, we applied a "modified Hoffmann approach", and verified the results with a more sophisticated statistical method (refineR). We compared our results with those of four recent studies using direct approaches. RESULTS: We evaluated a total of 81 sex- and age-specific reference intervals, for which at least 120 measurements were available. The overall agreement between indirectly and directly determined reference intervals was surprisingly good as nearly every fourth reference limit could be confirmed by narrow tolerance limits. Furthermore, lower reference limits could be provided for some low concentrated hormones by the indirect method. In cases of substantial deviations, our results matched the underlying data better than reference intervals from external studies. CONCLUSIONS: Our study shows for the first time that indirect methods are a valuable tool to verify existing reference intervals for steroid hormones. A simple "modified Hoffmann approach" based on the general assumption of a normal or lognormal distribution model is sufficient for screening purposes, while the refineR algorithm may be used for a more detailed analysis.


Assuntos
Esteroides , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Valores de Referência , Hormônios , Fatores Etários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA