Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Pediatr Cardiol ; 39(5): 1063-1065, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29736793

RESUMO

A 16-year-old female, with a history of Williams syndrome, presented to our institution with a 2-week history of intermittent dizziness. Holter monitoring demonstrated occasional premature ventricular contractions with rare couplets and triplets as well as one short run of nonsustained ventricular tachycardia. Echocardiography revealed an abnormal and irregular left ventricular septum with multiple mobile, pedunculated muscular projections extending into the left ventricular cavity. Cardiac MR confirmed abnormally thickened trabeculations consisting of multiple parallel ridges of myocardium crossing the left ventricle. The appearance of these findings closely resembled bands of coral lining the ocean floor. As such, this finding can henceforth be known as the "coral sign." To our knowledge, no other reports of this finding in patients with Williams syndrome have been published.


Assuntos
Miocárdio/patologia , Síndrome de Williams/diagnóstico por imagem , Adolescente , Antagonistas Adrenérgicos beta/uso terapêutico , Ecocardiografia/métodos , Eletrocardiografia Ambulatorial/métodos , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Taquicardia Ventricular/etiologia , Síndrome de Williams/tratamento farmacológico
2.
NMR Biomed ; 29(6): 841-61, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27100142

RESUMO

Macromolecular degeneration and biochemical changes in tissue can be quantified using rotating frame relaxometry in MRI. It has been shown in several studies that the rotating frame longitudinal relaxation rate constant (R1ρ ) and the rotating frame transverse relaxation rate constant (R2ρ ) are sensitive biomarkers of phenomena at the cellular level. In this comprehensive review, existing MRI methods for probing the biophysical mechanisms that affect the rotating frame relaxation rates of the tissue (i.e. R1ρ and R2ρ ) are presented. Long acquisition times and high radiofrequency (RF) energy deposition into tissue during the process of spin-locking in rotating frame relaxometry are the major barriers to the establishment of these relaxation contrasts at high magnetic fields. Therefore, clinical applications of R1ρ and R2ρ MRI using on- or off-resonance RF excitation methods remain challenging. Accordingly, this review describes the theoretical and experimental approaches to the design of hard RF pulse cluster- and adiabatic RF pulse-based excitation schemes for accurate and precise measurements of R1ρ and R2ρ . The merits and drawbacks of different MRI acquisition strategies for quantitative relaxation rate measurement in the rotating frame regime are reviewed. In addition, this review summarizes current clinical applications of rotating frame MRI sequences. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Imagem Molecular/métodos , Processamento de Sinais Assistido por Computador , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Rotação , Sensibilidade e Especificidade
3.
AJR Am J Roentgenol ; 206(6): 1298-306, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27010526

RESUMO

OBJECTIVE: The purpose of this study is to assess the performance of routinely used MRI sequences with and without contrast enhancement in the diagnostic evaluation of dural venous sinus thrombosis (DVST). MATERIALS AND METHODS: We identified consecutive patients older than 18 years who underwent concurrent standardized brain MRI and contrast-enhanced (CE) MR venography (MRV) examinations for suspected DVST. The seven MRI sequences that were used (axial unenhanced T1-weighted, T1-weighted CE, T2-weighted, DWI, T2-weighted FLAIR, T2-weighted gradient-recalled echo [GRE], and sagittal 3D T1-weighted GRE CE sequences) were randomized, anonymized, and reviewed independently by two neuroradiologists who were blinded to the final diagnosis. Ten separate venous sinus segments were evaluated. CE MRV was the reference standard for determining the presence or absence of DVST, and it was performed using the following imaging parameters: TR/TE, 4.1-77/1.4-9.5; flip angle, 12-35°; and slice thickness, 0.8-1.4 mm. The diagnostic performance of and interobserver variability for each sequence was assessed per patient and per segment. RESULTS: Thirty-six patients with DVST (72% of whom had acute thrombosis and 28% of whom had chronic thrombosis) and 29 patients without DVST were included in the study. For each sequence, the AUC values for the detection of DVST per patient, as determined by reviewer 1 and reviewer 2, respectively, were as follows: for T1-weighted unenhanced sequences, 55% and 61%; for T1-weighted CE sequences, 79% and 80%; for T2-weighted sequences, 77% and 76%; for DWI sequences, 59% and 64%; for T2-weighted FLAIR sequences, 70% and 72%; for T2-weighted GRE sequences, 64% and 66%; and for the 3D T1-weighted GRE CE sequence, 77% and 81%. The diagnostic performance of the 3D T1-weighted GRE CE sequences was statistically significantly greater than that of the other sequences. Interobserver variability ranged from 0.26 (for T1-weighted unenhanced sequences) to 0.73 (for the DWI sequence). Overall, for each reviewer and with the use of all evaluated sequences, MRI had a high sensitivity (> 99% for both reviewers) but low specificity (14% for reviewer 1 and 48% for reviewer 2) for the detection of DVST. CONCLUSION: Sequences used in routine brain MRI performed with and without contrast enhancement have varying strengths that are important to recognize when the likelihood of DVST is assessed, but they do not replace the utility of dedicated CE MRV.


Assuntos
Imageamento por Ressonância Magnética , Flebografia , Trombose dos Seios Intracranianos/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
4.
Med Phys ; 51(5): 3566-3577, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38128057

RESUMO

BACKGROUND: In prostate radiotherapy, the intrafractional target motion negatively affects treatment accuracy. Generating internal target volume (ITV) using four-dimensional (4D) images may resolve the issue of intrafractional target motion induced by bladder filling and bowel movement. However, no 4D imaging techniques suitable for the prostate are currently available in clinical practice. PURPOSE: This study aimed to determine the ITV based on cine magnetic resonance imaging (MRI) sequence for intrafractional target motion management in prostate MRI-guided radiotherapy. MATERIALS AND METHODS: A reference ITV was generated in simulation process. Then, the reference ITV was adapted with cine MRI sequence before online planning in each fraction. Finally, the reference ITV was updated with the cine MRI sequence acquired during beam delivery after each fraction. Cine MRI sequences and positioning three-dimensional (3D) MRI from 35 patients were retrospectively collected. Clinical target volume (CTV) coverage was computed according to the two-dimensional contour of CTV and ITV on cine MRI images. Relative target size was calculated as the ratio of the volume of ITV and CTV. Isotropic planning target volume (PTV; 5 mm margin) and anisotropic PTV (3 mm margin in the posterior direction and 5 mm margin in other directions) were generated for comparison. RESULTS: The CTV coverage rate of the proposed ITV had a mean value of 98.61% ± 0.51%, whereas the CTV coverage rates of the isotropic and anisotropic PTVs were 97.43% ± 0.41% and 96.58% ± 0.73%, respectively. The proposed ITV had a relative target size of 1.79 ± 0.17, whereas the anisotropic and isotropic PTVs had relative target sizes of 1.92 ± 0.12 and 2.21 ± 0.19, respectively. For both the CTV coverage rate and target relative size, significant differences were observed between the proposed ITV and the other two PTVs (p < 0.05). CONCLUSION: The ITV achieved higher CTV coverage with smaller size than conventional isotropic and anisotropic PTVs, indicating that it can effectively deal with the intrafractional movement of the prostate.


Assuntos
Imagem Cinética por Ressonância Magnética , Neoplasias da Próstata , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/diagnóstico por imagem , Radioterapia Guiada por Imagem/métodos , Imagem Cinética por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Movimento , Próstata/diagnóstico por imagem , Estudos Retrospectivos , Carga Tumoral
5.
J Magn Reson ; 350: 107424, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37001194

RESUMO

Every magnetic resonance imaging (MRI) device requires an electronic control system that handles pulse sequences and signal detection and processing. Here we provide details on the architecture and performance of MaRCoS, a MAgnetic Resonance COntrol System developed by an open international community of low-field MRI researchers. MaRCoS is inexpensive and can handle cycle-accurate sequences without hard length limitations, rapid bursts of events, and arbitrary waveforms. It has also been readily adapted to meet the requirements of the various academic and private institutions participating in its development. We describe the MaRCoS hardware, firmware and software that enable all of the above, including a Python-based graphical user interface for pulse sequence implementation, data processing and image reconstruction.

6.
Phys Imaging Radiat Oncol ; 27: 100481, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37655122

RESUMO

Hybrid systems that combine Magnetic Resonance Imaging (MRI) and linear accelerators are available clinically to guide and adapt radiotherapy. Vendor-approved MRI sequences are provided, however alternative sequences may offer advantages. The aim of this study was to develop a systematic approach for non-vendor sequence evaluation, to determine safety, accuracy and overall clinical application of two potential sequences for bladder cancer MRI guided radiotherapy. Non-vendor sequences underwent and passed clinical image qualitative review, phantom quality assurance, and radiotherapy planning assessments. Volunteer workflow tests showed the potential for one sequence to reduce workflow time by 27% compared to the standard vendor sequence.

7.
Front Cardiovasc Med ; 10: 1227495, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37680565

RESUMO

Background and purpose: Carotid atherosclerotic plaques with a large lipid-rich necrotic core (LRNC), intraplaque hemorrhage (IPH), and a thin or ruptured fibrous cap are associated with increased stroke risk. Multi-sequence MRI can be used to quantify carotid atherosclerotic plaque composition. Yet, its clinical implementation is hampered by long scan times and image misregistration. Multi-contrast atherosclerosis characterization (MATCH) overcomes these limitations. This study aims to compare the quantification of plaque composition with MATCH and multi-sequence MRI. Methods: MATCH and multi-sequence MRI were used to image 54 carotid arteries of 27 symptomatic patients with ≥2 mm carotid plaque on a 3.0 T MRI scanner. The following sequence parameters for MATCH were used: repetition time/echo time (TR/TE), 10.1/4.35 ms; field of view, 160 mm × 160 mm × 2 mm; matrix size, 256 × 256; acquired in-plane resolution, 0.63 mm2× 0.63 mm2; number of slices, 18; and flip angles, 8°, 5°, and 10°. Multi-sequence MRI (black-blood pre- and post-contrast T1-weighted, time of flight, and magnetization prepared rapid acquisition gradient echo; acquired in-plane resolution: 0.63 mm2 × 0.63 mm2) was acquired according to consensus recommendations, and image quality was scored (5-point scale). The interobserver agreement in plaque composition quantification was assessed by the intraclass correlation coefficient (ICC). The sensitivity and specificity of MATCH in identifying plaque composition were calculated using multi-sequence MRI as a reference standard. Results: A significantly lower image quality of MATCH compared to that of multi-sequence MRI was observed (p < 0.05). The scan time for MATCH was shorter (7 vs. 40 min). Interobserver agreement in quantifying plaque composition on MATCH images was good to excellent (ICC ≥ 0.77) except for the total volume of calcifications and fibrous tissue that showed moderate agreement (ICC ≥ 0.61). The sensitivity and specificity of detecting plaque components on MATCH were ≥89% and ≥91% for IPH, ≥81% and 85% for LRNC, and ≥71% and ≥32% for calcifications, respectively. Overall, good-to-excellent agreement (ICC ≥ 0.76) of quantifying plaque components on MATCH with multi-sequence MRI as the reference standard was observed except for calcifications (ICC = 0.37-0.38) and fibrous tissue (ICC = 0.59-0.70). Discussion and conclusion: MATCH images can be used to quantify plaque components such as LRNC and IPH but not for calcifications. Although MATCH images showed a lower mean image quality score, short scan time and inherent co-registration are significant advantages.

8.
Indian J Pediatr ; 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-38051445

RESUMO

OBJECTIVES: To compare and evaluate the usefulness of magnetic resonance imaging (MRI) with computed tomography (CT) in bronchiectasis; to compare MRI and CT scores with pulmonary function tests (PFT) and to evaluate the role of Diffusion-weighted imaging (DWI) in bronchiectasis. METHODS: In this prospective study, 25 patients between 7-21 y of age with a clinical/radiological diagnosis of bronchiectasis underwent MDCT and MRI chest. MRI and CT scoring was performed using modified Bhalla-Helbich's score by two independent radiologists for all parameters. A final consensus score was recorded. The overall image quality of different MRI sequences to identify pathologies was also assessed. Appropriate statistical tests were used for inter-observer agreements, and correlation amongst CT and MRI; as well as CT, MRI and PFT. RESULTS: Strong agreement (ICC 0.80-0.95) between CT and MRI was seen for extent and severity of bronchiectasis, number of bullae, sacculation/abscess, emphysema, collapse/ consolidation, mucus plugging, and mosaic perfusion. Overall CT and MRI scores had perfect concordance (ICC 0.978). Statistically significant (p-value <0.01) intra-observer and inter-observer agreement for all CT and MRI score parameters were seen. A strong negative correlation was seen between total CT and MRI severity scores and forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), forced expiratory flow (FEF) 25-75%. DWI MR, with an apparent diffusion coefficient (ADC) cut-off of 1.62 × 10-3 mm3/s had a sensitivity of 70% and specificity of 75% in detecting true mucus plugs. CONCLUSIONS: MRI with DWI can be considered as a radiation-free alternative in the diagnostic algorithm for assessment of lung changes in bronchiectasis, especially in follow-up.

9.
Med Phys ; 49(3): 1559-1570, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35075670

RESUMO

PURPOSE: To generate synthetic relative proton stopping power (sRPSP) images from magnetic resonance imaging (MRI) sequence(s) and develop an online quality assurance (QA) tool for sRPSP to facilitate safe integration of magnetic resonance (MR)-only proton planning into clinical practice. MATERIALS AND METHODS: Planning computed tomography (CT) and MR images of 195 pediatric brain tumor patients were utilized (training: 150, testing: 45). Seventeen consistent-cycle generative adversarial network (ccGAN) models were trained separately using paired CT-converted RPSP and MRI datasets to transform a subject's MRI into sRPSP. T1-weighted (T1W), T2-weighted (T2W), and FLAIR MRI were permutated to form 17 combinations, with or without preprocessing, for determining the optimal training sequence(s). For evaluation, sRPSP images were converted to synthetic CT (sCT) and compared to the real CT in terms of mean absolute error (MAE) in Hounsfield units (HU). For QA, sCT was deformed and compared to a reference template built from training dataset to produce a flag map, highlighting pixels that deviate by >100 HU and fall outside the mean ± standard deviation reference intensity. The gamma intensity analysis (10%/3 mm) of the deformed sCT against the QA template on the intensity difference was investigated as a surrogate of sCT accuracy. RESULTS: The sRPSP images generated from a single T1W or T2W sequence outperformed that generated from multi-MRI sequences in terms of MAE (all p < 0.05). Preprocessing with N4 bias and histogram matching reduced MAE of T2W MRI-based sCT (54 ± 21 HU vs. 42 ± 13 HU, p = 0.002). The gamma intensity analysis of sCT against the QA template was highly correlated with the MAE of sCT against the real CT in the testing cohort (r = -0.89 for T1W sCT; r = -0.93 for T2W sCT). CONCLUSION: Accurate sRPSP images can be generated from T1W/T2W MRI for proton planning. A QA tool highlights regions of inaccuracy, flagging problematic cases unsuitable for clinical use.


Assuntos
Neoplasias Encefálicas , Terapia com Prótons , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Criança , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Terapia com Prótons/métodos , Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
10.
Ear Nose Throat J ; : 1455613221131302, 2022 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-36193877

RESUMO

On a perilymphatic fistula, there is an extravasation of the perilymph fluid into the middle ear cavity. Cross-sectional imaging techniques have very important role in evaluation of inner and middle ear structures and temporal bone. While thin section CT scans can show successfully pneumolabyrinth and temporal bone fracture, high-resolution 3D volumetric MRI sequences can help to demonstrate posttraumatic ear effusion and cerebrospinal fluid fistula into inner ear or middle ear.

11.
Front Cardiovasc Med ; 9: 917180, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36247474

RESUMO

Late gadolinium enhancement (LGE) with cardiac magnetic resonance (CMR) imaging is the clinical reference for assessment of myocardial scar and focal fibrosis. However, current LGE techniques are confined to imaging of a single cardiac phase, which hampers assessment of scar motility and does not allow cross-comparison between multiple phases. In this work, we investigate a three step approach to obtain cardiac phase-resolved LGE images: (1) Acquisition of cardiac phase-resolved imaging data with varying T 1 weighting. (2) Generation of semi-quantitative T 1 * maps for each cardiac phase. (3) Synthetization of LGE contrast to obtain functional LGE images. The proposed method is evaluated in phantom imaging, six healthy subjects at 3T and 20 patients at 1.5T. Phantom imaging at 3T demonstrates consistent contrast throughout the cardiac cycle with a coefficient of variation of 2.55 ± 0.42%. In-vivo results show reliable LGE contrast with thorough suppression of the myocardial tissue is healthy subjects. The contrast between blood and myocardium showed moderate variation throughout the cardiac cycle in healthy subjects (coefficient of variation 18.2 ± 3.51%). Images were acquired at 40-60 ms and 80 ms temporal resolution, at 3T and 1.5, respectively. Functional LGE images acquired in patients with myocardial scar visualized scar tissue throughout the cardiac cycle, albeit at noticeably lower imaging resolution and noise resilience than the reference technique. The proposed technique bears the promise of integrating the advantages of phase-resolved CMR with LGE imaging, but further improvements in the acquisition quality are warranted for clinical use.

12.
Eur J Radiol ; 135: 109489, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33395595

RESUMO

PURPOSE: T1rho imaging is a new quantitative MRI sequence for head and neck cancer and the repeatability for this region is unknown. This study aimed to evaluate the repeatability of quantitative T1rho imaging in the head and neck. MATERIALS AND METHODS: T1rho imaging of the head and neck was prospectively performed in 15 healthy participants on three occasions. Scan 1 and 2 were performed with a time interval of 30 minutes (intra-session) and scan 3 was performed 14 days later (inter-session). T1rho values for normal tissues (parotid glands, palatine tonsils, pterygoid muscles, and tongue) were obtained on each scan. Intra-class coefficients (ICCs), within-subject coefficient of variances (wCoVs), and repeatability coefficient (RCs) of the intra-session scan (scan 1 vs 2) and inter-session scan (scan 1 vs 3) for the normal tissues were calculated. RESULTS: The ICCs of T1rho values for normal tissues were almost perfect (0.83-0.97) for intra-session scans and were substantial (0.71-0.80) for inter-session scans. The wCoVs showed a small range (2.46%-3.30%) for intra-session scans, and slightly greater range (3.27%-6.51%) for inter-session scan. The greatest and lowest wCoVs of T1rho were found in the parotid gland and muscles, respectively. The T1rho RCs varied for all tissues between intra- and inter- sessions, and the greatest RC of 10.07 msec was observed for parotid gland on inter-session scan. CONCLUSION: T1rho imaging is a repeatable quantitative MRI sequence in the head and neck but variances of T1rho values among tissues should be take into account during analysis.


Assuntos
Cabeça , Imageamento por Ressonância Magnética , Cabeça/diagnóstico por imagem , Humanos , Pescoço/diagnóstico por imagem , Glândula Parótida/diagnóstico por imagem , Reprodutibilidade dos Testes
13.
Front Neuroinform ; 15: 622951, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34867254

RESUMO

Despite the wide application of the magnetic resonance imaging (MRI) technique, there are no widely used standards on naming and describing MRI sequences. The absence of consistent naming conventions presents a major challenge in automating image processing since most MRI software require a priori knowledge of the type of the MRI sequences to be processed. This issue becomes increasingly critical with the current efforts toward open-sharing of MRI data in the neuroscience community. This manuscript reports an MRI sequence detection method using imaging metadata and a supervised machine learning technique. Three datasets from the Brain Center for Ontario Data Exploration (Brain-CODE) data platform, each involving MRI data from multiple research institutes, are used to build and test our model. The preliminary results show that a random forest model can be trained to accurately identify MRI sequence types, and to recognize MRI scans that do not belong to any of the known sequence types. Therefore the proposed approach can be used to automate processing of MRI data that involves a large number of variations in sequence names, and to help standardize sequence naming in ongoing data collections. This study highlights the potential of the machine learning approaches in helping manage health data.

14.
BMJ Open ; 9(8): e027020, 2019 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-31375607

RESUMO

OBJECTIVES: Single-use commercial surface fiducial markers are used in clinical imaging for a variety of applications. The current study sought to find a new, reliably visible, easily sourced and inexpensive fiducial marker alternative for use with MRI. DESIGN: Five commonly requested MRI sequences were determined (three-dimensional (3D) T1-weighted, T1 coronal, 3D T2-weighted, T2 fat suppressed, proton density), to examine the visibility of 18 items (including a commercial fiducial marker). SETTING: Clinical 3T MRI scanner in an Australian Tertiary Hospital and an Australian University Biomedical Engineering research group. INTERVENTIONS: 18 marker alternatives were scanned using five common MRI sequences. Images were reformatted to obtain both an image through the mid-height of each marker and a maximum intensity z-projection image over the volume of the marker. Variations in marker intensity were profiled across each visible marker and a visibility rating defined. MAIN OUTCOME MEASURES: Outcome measures were based on quantitative assessment of a clear intensity contrast ratio between the marker and the adjacent tissue and a qualitative assessment of visibility via a 3-point scale. RESULTS: The fish oil capsule, vitamin D capsule, paint ball pellet, soy sauce sushi tube and commercial markers were typically visible to a high quality on all the imaging sequences and demonstrated a clear differential in intensity contrast against the adjacent tissue. Other common items, such as plasticine 'play doh' and a soft 'Jelly baby' sweet, were surprise candidates, demonstrating high-quality visibility and intensity contrast for the 3D T1-weighted sequence. CONCLUSIONS: Depending on the basis for referral and MRI sequence chosen, four alternative fiducial markers were determined to be inexpensive, easily sourced and consistently visible. Of these, the vitamin D capsule provided an excellent balance between availability, size, cost, usability and quality of the visualised marker for all the commonly used MRI sequences analysed.


Assuntos
Marcadores Fiduciais/economia , Imageamento por Ressonância Magnética/métodos , Austrália , Pesquisa Biomédica , Humanos , Serviço Hospitalar de Radiologia , Reprodutibilidade dos Testes
15.
J Neurosurg ; 132(1): 140-149, 2019 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-30641849

RESUMO

OBJECTIVE: The object of this study was to clarify the expression characteristics and prognostic value of survivin in skull base chordomas. METHODS: In this retrospective study, the authors measured the expression of survivin at the mRNA level in 81 samples from 71 patients diagnosed with skull base chordomas at their hospital in the period from July 2005 to January 2015. Clinical data collection, follow-up, and survival analyses were performed, and correlations were analyzed. RESULTS: Of the 71 patients, 50 had primary chordomas with a mean survivin expression level of 1.09; the other 21 patients had recurrent chordomas with a mean survivin expression level of 2.57, which was 2.36 times higher than the level in the primary chordoma patients (p < 0.001, Mann-Whitney U-test). In addition, an analysis of 18 paired samples derived from 9 patients showed that the expression level of survivin was 2.62 times higher in recurrent tumors than in primary tumors (p = 0.002, paired t-test). The Spearman rank correlation coefficient method showed that the expression level of survivin was positively correlated with the mean ratio of tumor signal intensity to the signal intensity of surrounding brainstem on T1-weighted sequences (RT1; rs = 0.274, p = 0.021) and was negatively correlated with the mean ratio of tumor signal intensity to the signal intensity of surrounding brainstem on T2-weighted sequences (RT2; rs = -0.389, p = 0.001). A multivariate Cox proportional-hazards model suggested that pathology (p = 0.041), survivin expression level (p = 0.018), preoperative Karnofsky Performance Status (KPS; p = 0.012), and treatment history (p = 0.009) were independent prognostic factors for tumor progression. Survivin expression level (p = 0.008), preoperative KPS (p = 0.019), tumor diameter (p = 0.027), and intraoperative blood loss (p = 0.015) were independent prognostic factors for death. CONCLUSIONS: Survivin expression level and preoperative KPS were independent significant prognostic factors for tumor progression and death in skull base chordoma patients. Recurrent skull base chordomas and chordomas with high RT1 and low RT2 were likely to have high survivin expression. Other independent risk factors related to tumor progression included conventional pathology and treatment history, whereas additional mortality-related risk factors included larger tumor diameter and greater intraoperative blood loss.


Assuntos
Cordoma/química , Proteínas de Neoplasias/análise , Neoplasias da Base do Crânio/química , Survivina/análise , Adulto , Perda Sanguínea Cirúrgica , Cordoma/mortalidade , Cordoma/patologia , Cordoma/terapia , Terapia Combinada , Irradiação Craniana , Craniotomia , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/química , Recidiva Local de Neoplasia/mortalidade , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/terapia , Neuroimagem , Prognóstico , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Neoplasias da Base do Crânio/mortalidade , Neoplasias da Base do Crânio/patologia , Neoplasias da Base do Crânio/terapia
16.
J Clin Diagn Res ; 11(8): TC17-TC22, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28969239

RESUMO

INTRODUCTION: Spinal dysraphism occurs due to failure of fusion of parts along dorsal aspect of midline structures lying along spinal axis from skin to vertebrae and spinal cord. Congenital spinal anomalies may be minimal and asymptomatic like spinal bifida occulta, or severe with marked neurological deficits like Arnold-Chiari malformation or caudal regression syndrome. Magnetic Resonance Imaging (MRI) is the modality of choice to diagnose mild to severe spinal dysraphism. AIM: To diagnose type and extent of clinically suspected spinal anomalies by MRI scan and to compare various sequences for identifying neural tissue and fatty tissue in anomalies. MATERIALS AND METHODS: Fifty paediatric patients referred with clinical suspicion of spinal anomalies for MRI scan to radiodiagnosis department and diagnosed as having spinal dysraphism on 1.5 Tesla MRI Scan, were included in this observational analytic study. Various MRI sequences were taken in multiple planes. MRI findings of spinal dysraphism were compared with detailed clinical examination or surgical findings. Osseous anomalies like spina bifida occulta were confirmed by radiographs or CT scan. RESULTS: Out of 50 patients, type II Arnold-Chiari Malformation (34%), Spina Bifida Occulta (22%) and Diastematomyelia (18%) were common anomalies. MRI findings were well correlated with surgical findings in 20 operated cases. Nerve roots with/ without neural placode in thecal sac/outpouching were detected in combination of 3D HASTE myelographic sequence with SE/ TSE T1W sequence in 24 cases; which was significantly high as compared to combinations of SE/TSE T1W sequence with TSE T2W, with STIR and with Single Shot Myelographic sequence {p-value 0.002, < 0.001 and 0.008 respectively}. Fatty component was present in dysraphism in five cases, commonly as isolated anomaly; which was detected by combination of STIR and SE/TSE T1W sequences in all five cases. CONCLUSION: Paediatric spinal dysraphism and associated malformations are accurately diagnosed on MRI scan. MR myelographic 3D-HASTE and STIR sequences should be a part of protocol to evaluate spinal dysraphism.

17.
J Nucl Med ; 55(6): 923-31, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24833495

RESUMO

UNLABELLED: Technologic specifications of recently introduced integrated PET/MR instrumentation, such as MR-based attenuation correction, may particularly affect brain imaging procedures. To evaluate the qualitative performance of PET/MR in clinical neuroimaging, we systematically compared results obtained with integrated PET/MR with conventional PET/CT in the same patients examined for assessment of cognitive impairment. METHODS: Thirty patients underwent a single-injection ((18)F-FDG), dual-imaging protocol including PET/CT and integrated PET/MR imaging in randomized order. Attenuation and scatter correction were performed using low-dose CT for the PET/CT and segmented Dixon MR imaging data for the PET/MR. Differences between PET/MR and PET/CT were assessed via region-of-interest (ROI)-based and voxel-based statistical group comparison. Analyses involved attenuation-corrected (AC) and non-attenuation-corrected (NAC) data. Individual PET/MR and PET/CT datasets were compared versus a predefined independent control population, using 3-dimensional stereotactic surface projections. RESULTS: Generally, lower measured PET signal values were obtained throughout the brain in ROI-based quantification of the PET signal for PET/MR as compared with PET/CT in AC and NAC data, independently of the scan order. After elimination of global effects, voxel-based and ROI-based group comparison still revealed significantly lower relative tracer signal in PET/MR images in frontoparietal portions of the neocortex but significantly higher relative signal in subcortical and basal regions of the brain than the corresponding PET/CT images of the AC data. In the corresponding NAC images, the discrepancies in frontoparietal portions of the neocortex were diminished, but the subcortical overestimation of tracer intensity by PET/MR persisted. CONCLUSION: Considerable region-dependent differences were observed between brain imaging data acquired on the PET/MR, compared with corresponding PET/CT images, in patients evaluated for neurodegenerative disorders. These findings may only in part be explained by inconsistencies in the attenuation-correction procedures. The observed differences may interfere with semiquantitative evaluation and with individual qualitative clinical assessment and they need to be considered, for example, for clinical trials. Improved attenuation-correction algorithms and a PET/MR-specific healthy control database are recommended for reliable and consistent application of PET/MR for clinical neuroimaging.


Assuntos
Encéfalo/diagnóstico por imagem , Demência/diagnóstico , Fluordesoxiglucose F18 , Imagem Multimodal/métodos , Imagem Corporal Total , Adulto , Idoso , Demência/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X
18.
Magn Reson Imaging Clin N Am ; 22(3): 263-82, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25086929

RESUMO

This article describes a basic 1.5-T hepatic magnetic resonance (MR) imaging protocol, strategies for optimizing pulse sequences while managing artifacts, the proper timing of postgadolinium 3-dimensional gradient echo sequences, and an effective order of performing pulse sequences with the goal of creating an efficient and high-quality hepatic MR imaging examination. The authors have implemented this general approach on General Electric, Philips, and Siemens clinical scanners.


Assuntos
Meios de Contraste , Gadolínio , Aumento da Imagem/métodos , Hepatopatias/diagnóstico , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Artefatos , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Imageamento Tridimensional/métodos , Fígado/anatomia & histologia
19.
Case Rep Neurol ; 3(3): 223-6, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22121349

RESUMO

The present post-mortem study of a brain from an Alzheimer patient showed on a T(2)∗-weighted gradient-echo 7.0-T MRI of a coronal brain section a hyposignal in the hippocampus, suggesting a microbleed. On the corresponding histological examination, only iron deposits around the granular cellular layer and in blood vessel walls of the hippocampus were observed without evidence of a bleeding. This case report illustrates that the detection of microbleeds on MRI has to be interpreted with caution.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA