Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 578
Filtrar
1.
Proc Natl Acad Sci U S A ; 120(39): e2305078120, 2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-37695879

RESUMO

Current un-sustainable plastic management is exacerbating plastic pollution, an urgent shift is thus needed to create a recycling society. Such recovering carbon (C) and hydrogen (H) from waste plastic has been considered as one practical route to achieve a circular economy. Here, we performed a simple pyrolysis-catalysis deconstruction of waste plastic via a monolithic multilayer stainless-steel mesh catalyst to produce multiwalled carbon nanotubes (MWCNTs) and H2, which are important carbon material and energy carrier to achieve sustainable development. Results revealed that the C and H recovery efficiencies were as high as 86% and 70%, respectively. The unique oxidation-reduction process and improvement of surface roughness led to efficient exposure of active sites, which increased MWCNTs by suppressing macromolecule hydrocarbons. The C recovery efficiency declined by only 5% after 10 cycles, proving the long-term employment of the catalyst. This catalyst can efficiently convert aromatics to MWCNTs by the vapor-solid-solid mechanism and demonstrate good universality in processing different kinds of waste plastics. The produced MWCNTs showed potential in applications of lithium-ion batteries and telecommunication. Owing to the economic profits and environmental benefits of the developed route, we highlighted its potential as a promising alternative to conventional incineration, simultaneously achieving the waste-to-resource strategy and circular economy.

2.
Small ; : e2403218, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38963069

RESUMO

In recent years, the implementation of energy-harvesting technology in medical equipment has attracted significant interest owing to its potential for self-powered and smart healthcare systems. Herein, the integration of a triboelectric nanogenerator (TENG) is proposed into an inhaler for energy-harvesting and smart inhalation monitoring. For this initially, barium sodium niobium oxide (Ba2NaNb5O15) microparticles (BNNO MPs) are synthesized via a facile solid-state synthesis process. The BNNO MPs with ferroelectricity and high dielectric constant are incorporated into polydimethylsiloxane (PDMS) polymer to make BNNO/PDMS composite films (CFs) for TENG fabrication. The fabricated TENG is operated in a contact-separation mode, and its electrical output performance is compared to establish the optimal BNNO MPs concentration. Furthermore, multi-wall carbon nanotubes (MWCNTs), a conductive filler material, are used to enhance the electrical conductivity of the CFs, thereby improving the electrical output performance of the TENG. The robustness/durability of the proposed BNNO-MWCNTs/PDMS CF-based TENG are investigated. The proposed TENG device is demonstrated to harvest electrical energy from mechanical motions via regular human activities and power portable electronics. The TENG is integrated into the inhaler casing to count the number of sprays remaining in the canister, send the notification to a smartphone via Bluetooth, and harvest energy.

3.
Anal Bioanal Chem ; 416(13): 3149-3160, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38563959

RESUMO

Bats are the second largest mammalian order and are an endangered species group with a strong need for contamination monitoring. To facilitate non-invasive monitoring of the ecological burden in bat populations, a multiresidue method for the simultaneous quantification of 119 analytes including pesticides, persistent organic pollutants (POPs), active pharmaceutical ingredients (APIs), polycyclic aromatic hydrocarbons (PAHs), UV blockers, plasticizers, and other emerging pollutants in bat guano with gas chromatography tandem mass spectrometry (GC-MS/MS) was developed. Sample preparation and clean-up were performed with a modified QuEChERS approach based on DIN EN 15662. The method uses 1.00 g bat guano as sample with acetonitrile and water for liquid-liquid extraction. Phase separation is assisted by citrate-buffered salting out agent. For clean-up of the extract, primary secondary amine (PSA) was combined with graphitized carbon black (GCB). The lower limits of quantification (LLOQ) ranged between 2.5 and 250 µg kg-1. Linearity was shown in a concentration range from the respective LLOQs to 1250 µg kg-1. The median of the mean recovery was 102.4%. Precision was tested at three concentrations. Method and injection precision were adequate with a relative standard deviation (RSD) below 20%. Furthermore, the comparative analysis with LC-MS/MS demonstrated the reliability of the results and provided a valuable extension of the analytical scope. As proof of concept, three guano samples from a German nursery roost of Myotis myotis were analysed. The results show a time-dependent change in contaminant concentration, highlighting the strong need for non-invasive contamination monitoring of whole bat populations.


Assuntos
Quirópteros , Cromatografia Gasosa-Espectrometria de Massas , Limite de Detecção , Espectrometria de Massas em Tandem , Animais , Espectrometria de Massas em Tandem/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Hidrocarbonetos Policíclicos Aromáticos/análise , Reprodutibilidade dos Testes , Extração Líquido-Líquido/métodos , Monitoramento Ambiental/métodos
4.
Environ Toxicol ; 39(9): 4431-4446, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38856197

RESUMO

Multi-walled carbon nanotubes (MWCNTs) and halloysite nanotubes (HNTs) are widely used tubular-structured nanomaterials (NMs), but their cardiovascular effects are not clear. This study compared the effects of MWCNTs and HNTs on lipid profiles in mouse plasma and gene expression profiles in aortas and hearts. Mice were intravenously injected with 50 µg NMs, once a day, for 5 days. Then, the plasma was collected for lipidomics analysis, and aortas and hearts were collected for RNA-sequencing analysis. While MWCNTs or HNTs did not induce obvious pathological changes in aortas or hearts, the lipid profiles in mouse plasma were altered. Further analysis revealed that MWCNTs more effectively upregulated sphingolipids and sterol lipids, whereas HNTs more effectively upregulated glycerophospholipids and fatty acyls. Consistently, RNA-sequencing data indicated that MWCNTs and HNTs altered signaling pathways related with lipid synthesis and metabolism, as well as those related with endoplasmic reticulum, lysosomes and autophagy, more significantly in aortas than in hearts. We further verified the changes of proteins involved in autophagic lipolysis, that MWCNTs were more effectively to suppress the autophagic biomarker LC3, whereas HNTs were more effectively to affect lipid metabolism proteins. These results may provide novel understanding about the influences of MWCNTs and HNTs on lipid profiles and lipid signaling pathways in cardiovascular systems. Importantly, previous studies considered HNTs as biocompatible materials, but the results from this study suggested that both MWCNTs and HNTs were capable to affect lipid profiles and autophagic lipolysis pathways in cardiovascular systems, although their exact influences were different.


Assuntos
Aorta , Autofagia , Miocárdio , Nanotubos de Carbono , Animais , Nanotubos de Carbono/toxicidade , Autofagia/efeitos dos fármacos , Camundongos , Masculino , Aorta/efeitos dos fármacos , Aorta/metabolismo , Miocárdio/metabolismo , Argila/química , Nanotubos/química , Nanotubos/toxicidade , Metabolismo dos Lipídeos/efeitos dos fármacos , Lipídeos/sangue , Camundongos Endogâmicos C57BL , Coração/efeitos dos fármacos
5.
Mikrochim Acta ; 191(5): 269, 2024 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630309

RESUMO

A molecularly-imprinted electrochemiluminescence sensor was constructed for the determination of fenpropathrin (FPT) by molecular imprinting technology. In this sensing platform, the introduction of CdS@MWCNTs significantly enhanced the initial ECL signal of the luminol-O2 system. Specifically, MWCNTs was used as a carrier to adsorb more CdS, in which CdS acted as a co-reaction promoter for luminescence. Molecularly imprinted polymer (MIP) containing specific recognition sites of FPT was used as the material for selective recognition. With increasing amount of FPT the ECL signal decreased. Under the optimum conditions, the ECL response was linearly related to the logarithm of FPT concentration. The developed ECL sensor allowed for sensitive determination of FPT and exhibited a wide linear range from 1.0 × 10- 10 mol L- 1 to 1.0 × 10- 6 mol L- 1. The limit of detection was 3.3 × 10- 11 mol L- 1 (S/N = 3). It can be used for the detection of FPT in vegetable samples.


Assuntos
Luminescência , Impressão Molecular , Piretrinas , Luminol , Polímeros Molecularmente Impressos
6.
Molecules ; 29(7)2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38611740

RESUMO

It is urgent to develop a polyamide (PA) thin-film composite (TFC) membrane with a new method in this study by designing and constructing a new nanomaterial support layer instead of the conventional support layer. Polydopamine-wrapped single-walled carbon nanotubes (PDA@MWCNTs) as the place of the polymerization reaction can optimize the PA film structure and performance. The resulting composite membrane presents a higher water flux of 15.8 L·m-2·h-1·bar-1 and a rejection rate of 97% to Na2SO4, simultaneously maintaining this high separation performance in 300 min. It is a new ideal to construct novel support layer by using inorganic nanoparticles and organic polymer nanofiber membranes.

7.
Molecules ; 29(6)2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38543001

RESUMO

The durability of wooden heritage objects and sites can be affected by external environmental factors, leading to decay, cracking, and other forms of deterioration, which might ultimately result in significant and irreversible loss. In this study, a FEVE resin was modified with Ag2O/OH-MWCNTS (MA), denoted as MAF, where three concentrations were prepared using in situ precipitation, and the resulting composite adhesive was characterized by a high viscosity and effective bacteriostatic properties, demonstrating a better viscosity and thermal stability, as well as antibacterial properties, than pure FEVE resin. The results show that MAF adhesives present good thermal stability, as evidenced by a lower mass loss rate following treatment at 800 °C compared to the pure FEVE resin. At a consistent shear rate, the viscosity of MAF demonstrates a notable increase with the proportion of MA, which is better than that of FEVE. This suggests that the nano-Ag2O particles in MA act as physical crosslinking agents in FEVE, improving the viscosity of the composite adhesive MAF. The adhesion strength between MAF and wood exhibits a similar trend, with wooden samples showing higher shear strengths as the proportion of MA increases in comparison to FEVE. Simultaneously, the antibacterial effects of the MAF adhesive exceeded 1 mm for Trichoderma, Aspergillus niger, and white rot fungi. The antibacterial activity of the MAF adhesive exhibited a direct correlation with the concentration of Ag2O/OH-MWCNTS, with the most pronounced inhibitory effect observed on Trichoderma. The MAF adhesive demonstrates promising prospects as an adhesive for wooden heritage artifacts, offering a novel approach for the rapid, environmentally friendly, and efficient development of composite adhesives with superior adhesive properties.

8.
Small ; 19(45): e2302795, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37415517

RESUMO

Pyridinic nitrogen has been recognized as the primary active site in nitrogen-doped carbon electrocatalysts for the oxygen reduction reaction (ORR), which is a critical process in many renewable energy devices. However, the preparation of nitrogen-doped carbon catalysts comprised of exclusively pyridinic nitrogen remains challenging, as well as understanding the precise ORR mechanisms on the catalyst. Herein, a novel process is developed using pyridyne reactive intermediates to functionalize carbon nanotubes (CNTs) exclusively with pyridine rings for ORR electrocatalysis. The relationship between the structure and ORR performance of the prepared materials is studied in combination with density functional theory calculations to probe the ORR mechanism on the catalyst. Pyridinic nitrogen can contribute to a more efficient 4-electron reaction pathway, while high level of pyridyne functionalization result in negative structural effects, such as poor electrical conductivity, reduced surface area, and small pore diameters, that suppressed the ORR performance. This study provides insights into pyridine-doped CNTs-functionalized for the first time via pyridyne intermediates-as applied in the ORR and is expected to serve as valuable inspiration in designing high-performance electrocatalysts for energy applications.

9.
Environ Res ; 238(Pt 1): 117026, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37659642

RESUMO

Exposure to thallium (Tl), a noxious heavy metal, poses significant health risks to both humans and animals upon ingestion. Therefore, monitoring Tl levels in the environment is crucial to prevent human exposure and reduce the risk of developing severe health problems. This paper presents the development of a highly sensitive Tl ions sensor through surface modification of a glassy carbon electrode with a nanocomposite comprising MnO2 magnetic sepiolite and multi-walled carbon nanotubes (MnO2@Fe3O4/Sep/MWCNT/GCE). Multiple methodologies were employed to assess the performance of the newly developed sensor. By employing square wave anodic stripping voltammetry (SWASV) to optimize the measurement conditions, notable enhancements were observed in the stripping peak currents of Tl (I) on the MnO2@Fe3O4/Sep/MWCNT/GCE surface. The effectiveness of the nanocomposite in facilitating electron transfer between the Tl (I) ions (guest) and the electrode (host) was demonstrated from the enhanced signals observed at the different modified electrode surfaces under optimal conditions. The developed sensor displayed a wide linear range of 0.1-1500 ppb for Tl (I) and a low detection limit of 0.03 ppb for Tl (I). It was found to be selective for Tl (I) ions while remaining unaffected by interfering non-target ions in the presence of the target ions. Despite its simple preparation procedure, the modified electrode exhibited high stability and excellent reproducibility for measuring Tl (I). The outstanding electroanalytical performances of the MnO2@Fe3O4/Sep/MWCNT/GCE electrode enabled its successful use as an ultrasensitive sensor for determining trace amounts of Tl in environmental samples.


Assuntos
Nanotubos de Carbono , Tálio , Animais , Humanos , Reprodutibilidade dos Testes , Compostos de Manganês , Limite de Detecção , Óxidos
10.
Mikrochim Acta ; 190(6): 214, 2023 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-37171612

RESUMO

A new ultrasensitive sandwich-type electrochemical immunosensor has been successfully constructed to quantitatively detect carcinoembryonic antigen (CEA) using blackberry-like mesoporous bismuth-based nanospheres NaBiOF (NBOF NSs) inlaid with Pt nanodots (NDs) (BiPt NSs) as the antibody capture and signal-amplifying probe. The growth of Pt NDs inside the holes of NBOF NSs formed the nanozyme inlay outside NBOF NSs, greatly increasing the specific surface area and exposure of the catalytic active sites by minimizing the particle size of the Pt to nanodot scale. Such a blackberry-shaped heterojunction structure of BiPt NSs was well-suited to antibody capture and improved the catalytic performance of BiPt NSs in reducing H2O2, amplifying the signal, and yielding highly sensitive detection of CEA. The use of Au nanoparticle-modified multi-walled carbon nanotubes (Au@MWCNTs) as the electrode substrates significantly enhanced the electron transfer behavior over the electrode surface, further increasing the conductivity and sensitivity of the immunosensor. Remarkably, good compatibility with human body fluid was achieved using the newly developed BiPt-based immunosensor resulting from the favorable biocompatibility and stability of both BiPt NSs and Au@MWCNTs. Benefiting from the double signal amplification strategy and the high biocompatibility, the immunosensor responded linearly to CEA in a wide range from 50 fg/mL to 100 ng/ml with an extremely low detection limit of 3.52 fg/mL (S/N = 3). The excellent detection properties of this new immunosensor were evidenced by the satisfactory selectivity, reproducibility, and stability obtained, as well as the reliable and precise determination  of CEA in actual human blood samples. This work provides a new strategy for the early clinical diagnosis of cancer. Novel blackberry-like mesoporous NaBiOF nanospheres with Pt nanodot inlay were successfully usedto construct a sandwich-type electrochemical immunosensor for the ultra-sensitive detection ofcarcinoembryonic antigen in human blood plasma based on a remarkable signal amplification strategy.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Nanotubos de Carbono , Humanos , Antígeno Carcinoembrionário , Ouro/química , Técnicas Biossensoriais/métodos , Nanotubos de Carbono/química , Peróxido de Hidrogênio/química , Reprodutibilidade dos Testes , Nanopartículas Metálicas/química , Anticorpos Imobilizados/química , Técnicas Eletroquímicas/métodos , Imunoensaio/métodos , Anticorpos
11.
Mikrochim Acta ; 190(7): 259, 2023 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-37306766

RESUMO

A novel Fe3O4-MWCNTs@Hemin nanocomposite was synthesized using hemin and Fe3O4 with multi-walled carbon nanotubes (MWCNTs) by one-step hydrothermal methods. The as-prepared Fe3O4-MWCNTs@Hemin nanocomposites exhibited excellent peroxidase-like activities in the activation of H2O2. The mechanisms, kinetics, and catalytic performances of Fe3O4-MWCNTs@Hemin were systematically studied. Fe3O4-MWCNTs@Hemin can oxidize dopamine (DA) to dopaquinone in the presence of H2O2, and the intermediate products dopaquinone can further react with ß-naphthol to generate a highly fluorescent derivative at 415 nm excitation wavelength. Therefore, an innovative fluorescence platform for the detection of DA was developed. The fluorescence intensity increased linearly with DA concentration in the range 0.33 to 107 µM, with a low detection limit of 0.14 µM. Due to the excellent activity, substrate universality, fast response, high selectivity, and sensitivity of Fe3O4-MWCNTs@Hemin, the proposed fluorescence method was used to analyze complex biological blood samples with a satisfactory result. It demonstrated the significant potential for developing effective and dependable fluorescent analytical platforms for preserving human health.


Assuntos
Dopamina , Nanotubos de Carbono , Humanos , Corantes , Hemina , Peróxido de Hidrogênio , Peroxidases
12.
Mikrochim Acta ; 191(1): 48, 2023 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-38141091

RESUMO

The synergistic armor-etching (SAE) approach was proposed using natural organic weak acid (tannic acid, i.e., TA) for the controllable assembly of hollow and interpenetrated HZIF-8@MWCNTs hybrid nanomaterial (ZIF-8, zeolitic imidazolate framework-8; MWCNTs, multi-walled carbon nanotubes), which exhibited highly ordered crystal structure and unique morphological characteristics. The SAE strategy not only can rapidly etch solid ZIF- material into a hollow structure (~ 10 min), but also form the TA shell (~ 33 nm) on its surface. Then, the HZIF-8@MWCNTs electrochemical sensor was constructed for selective and sensitive detection of the target molecule (dopamine, DA). A sequence of studies indicated that the fabricated TA coating was capable of promoting the spread of DA into the reactive centers of hollow MOF and MWCNTs, which exhibited outstanding electroanalytical characteristics through the synergistic effect. The DPV oxidation peak of DA was strongest at 50 mV vs. Ag/AgCl reference electrode. Under the optimal conditions, there are two linear dynamic ranges of current response of 0.01 ~ 10 and 10 ~ 550 µmol L- 1 with a detection limit of 0.003 µmol·L- 1 (S/N = 3). Simultaneously, the HZIF-8@MWCNTs electrochemical sensor could detect low levels of DA in real products. The recoveries of the actual sample tests were between 98.2% and 102%, and the relative standard deviation (R.S.D.) of all studies was less than 3.0%. The statistical analyses (F-test and t-test) were employed to demonstrate the accuracy of method developed. This work will enlighten researchers operating in the domain of MOFs composites, accelerating the advancement of electrochemical sensing on the basis of hollow MOFs materials.

13.
Mikrochim Acta ; 190(10): 409, 2023 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-37733170

RESUMO

Alzheimer's disease (AD) is considered one of the main progressive chronic diseases in elderly individuals. Early diagnosis using related biomarkers, specifically beta-amyloid peptide (Aß), allows finding expected treatment routes. Here, we developed an electrochemical aptasensing platform for AD by employing a glassy carbon electrode (GCE) modified with a layer of jagged gold (JG) nanostructure (diameter: 60-185 nm) and graphene oxide-carboxylic acid functionalized multiwalled carbon nanotubes (GO-c-MWCNTs) nanocomposite. These surface modifications acted as the signal amplifier and provided an optimum nano-interface substrate for immobilizing aptamer strands. The measurements of Aß were performed via differential pulse voltammetry (DPV), and the aptasensor detected the analyte in a linear range from 0.1 pg mL-1 to 1 ng mL-1, with an estimated limit of detection (LOD) of about 0.088 pg mL-1 (S/N = 3). The aptasensor showed sufficient stability (11 days), reversibility (three times), and reproducibility (five times re-fabrication with relative standard deviation (RSD): 1.27). The potential interfering agents showed negligible impact on the sensing performance. Finally, the application of the aptasensor was evaluated in the presence of 10 serum samples, and the recovery values were from 93 to 110.1%.


Assuntos
Doença de Alzheimer , Nanocompostos , Nanotubos de Carbono , Idoso , Humanos , Doença de Alzheimer/diagnóstico , Reprodutibilidade dos Testes , Ouro
14.
Sensors (Basel) ; 23(23)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38067933

RESUMO

The application of traditional pressure sensors in health monitoring is limited by their initial rigidity. Flexible pressure sensors have thus received extensive attention owing to their excellent device flexibility. In this paper, we demonstrate a method of constructing flexible pressure sensors by inverting porous skeleton nickel foam based on multi-wall carbon nanotubes (MWCNTs) and polydimethylsiloxane (PDMS). MWCNTs and PDMS were mixed to form a composite conductive film, and the mass fraction of MWCNTs was optimized by evaluating the resistance change rate of the composite film. The optimized value of the mass fraction was 5%, which was used to prepare the flexible pressure sensors. The response, hysteresis, and stability of the sensors were further characterized. Pulse signals of humans were detected through flexible sensors, which can be used to evaluate cardiovascular conditions of the human body. These performance characteristics and the application demonstration show that our flexible pressure sensors have good prospects in human health care.

15.
Sensors (Basel) ; 23(18)2023 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-37765789

RESUMO

In this work we describe a straightforward approach for creating a nanocomposite comprising multiwalled carbon nanotubes (MWCNTs) and titanium dioxide (TiO2) using the hydrothermal technique, which is then characterized by scanning electron microscope (SEM), energy-dispersive X-ray spectrometer (EDS), X-ray diffraction analysis (XRD), Fourier transform infrared spectroscopy (FTIR), and thermal gravimetric analysis (TGA) to assess its properties. Nafion is employed as a reticular agent for the nanocomposite on the glassy carbon electrode (GCE), creating the MWCNT/TiO2/Nafion/GCE system. The electrochemical behavior of the system was evaluated using cyclic voltammetry, revealing its remarkable electrocatalytic activity for detecting hydrogen peroxide in water. The developed sensor showcased a broad linear response range of 14.00 to 120.00 µM, with a low detection limit of 4.00 µM. This electrochemical sensor provides a simple and highly sensitive method for detecting hydrogen peroxide in aqueous solutions and shows promising potential for various real-world applications, particularly in H2O2 monitoring.

16.
Sensors (Basel) ; 23(22)2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-38005597

RESUMO

This paper describes the development of a simple voltammetric biosensor for the stereoselective discrimination of myo-inositol (myo-Ins) and D-chiro-inositol (D-chiro-Ins) by means of bovine serum albumin (BSA) adsorption onto a multi-walled carbon nanotube (MWCNT) graphite screen-printed electrode (MWCNT-GSPE), previously functionalized by the electropolymerization of methylene blue (MB). After a morphological characterization, the enantioselective biosensor platform was electrochemically characterized after each modification step by differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). The results show that the binding affinity between myo-Ins and BSA was higher than that between D-chiro-Ins and BSA, confirming the different interactions exhibited by the novel BSA/MB/MWCNT/GSPE platform towards the two diastereoisomers. The biosensor showed a linear response towards both stereoisomers in the range of 2-100 µM, with LODs of 0.5 and 1 µM for myo-Ins and D-chiro-Ins, respectively. Moreover, a stereoselectivity coefficient α of 1.6 was found, with association constants of 0.90 and 0.79, for the two stereoisomers, respectively. Lastly, the proposed biosensor allowed for the determination of the stereoisomeric composition of myo-/D-chiro-Ins mixtures in commercial pharmaceutical preparations, and thus, it is expected to be successfully applied in the chiral analysis of pharmaceuticals and illicit drugs of forensic interest.


Assuntos
Inositol , Azul de Metileno , Estereoisomerismo
17.
Sensors (Basel) ; 23(3)2023 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-36772172

RESUMO

Developing label-free immunosensors to detect ovarian cancer (OC) by cancer antigen (CA125) is essential to improving diagnosis and protecting women from life-threatening diseases. Four types of carbon nanomaterials, such as multi-wall carbon nanotubes (MWCNTs), vapor-grown carbon fiber (VGCFs), graphite KS4, and carbon black super P (SP), have been treated with acids to prepare a carbon nanomaterial/gold (Au) nanocomposite. The AuNPs@carbon nanocomposite was electrochemically deposited on a glassy carbon electrode (GCE) to serve as a substrate to fabricate a label-free immunosensor for the detection of CA125. Among the four AuNPs@carbon composite, the AuNPs@MWCNTs-based sensor exhibited a high sensitivity of 0.001 µg/mL for the biomarker CA125 through the square wave voltammetry (SWV) technique. The high conductivity and surface area of MWCNTs supported the immobilization of AuNPs. Moreover, the carboxylic (COO-) functional groups in MWCNT improved to a higher quantity after the acid treatment, which served as an excellent support for the fabrication of electrochemical biosensors. The present method aims to explore an environmentally friendly synthesis of a layer-by-layer (LBL) assembly of AuNPs@carbon nanomaterials electrochemical immunoassay to CA125 in a clinical diagnosis at a low cost and proved feasible for point-of-care diagnosis.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Nanotubos de Carbono , Neoplasias Ovarianas , Humanos , Feminino , Técnicas Biossensoriais/métodos , Ouro , Imunoensaio/métodos , Neoplasias Ovarianas/diagnóstico , Eletrodos , Técnicas Eletroquímicas/métodos , Limite de Detecção
18.
Int J Mol Sci ; 24(3)2023 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-36769277

RESUMO

This research intended to report amine-functionalized multiwall carbon nanotubes (MWCNTs) prepared by a simple method for efficient and rapid removal of Reactive Yellow 2 (RY2) from water. EDS analysis showed that the N content increased from 0 to 2.42% and from 2.42 to 8.66% after modification by 3-Aminopropyltriethoxysilane (APTES) and polyethylenimine (PEI), respectively. BET analysis displayed that the specific surface area, average pore size, and total pore volume were reduced from 405.22 to 176.16 m2/g, 39.67 to 6.30 nm, and 4.02 to 0.28 cm3/g, respectively. These results proved that the PEI/APTES-MWCNTs were successfully prepared. pH edge experiments indicated that pH 2 was optimal for RY2 removal. At pH 2 and 25 °C, the time required for adsorption equilibrium was 10, 15, and 180 min at initial concentrations of 50, 100, and 200 mg/L, respectively; and the maximum RY2 uptake calculated by the Langmuir model was 714.29 mg/g. Thermodynamic studies revealed that the adsorption process was spontaneous and endothermic. Moreover, 0-0.1 mol/L of NaCl showed negligible effect on RY2 removal by PEI/APTES-MWCNTs. Five adsorption/desorption cycles confirmed the good reusability of PEI/APTES-MWCNTs in RY2 removal. Overall, the PEI/APTES-MWCNTs are a potential and efficient adsorbent for reactive dye wastewater treatment.


Assuntos
Nanotubos de Carbono , Poluentes Químicos da Água , Nanotubos de Carbono/química , Polietilenoimina/química , Adsorção , Água , Poluentes Químicos da Água/química , Cinética
19.
Molecules ; 28(4)2023 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-36838859

RESUMO

Multiwalled carbon nanotubes (MWCNTs) were modified by oxidation and acidification with concentrated HNO3 and H2SO4, and the modified multiwalled carbon nanotubes (M-MWCNTs) and raw MWCNTs were characterized by several analytical techniques. Then the demanganization effects of MWCNTs and M-MWCNTs were well investigated and elucidated. The experimental data demonstrated that the adsorption efficiency of Mn(II) could be greatly promoted by M-MWCNTs from about 20% to 75%, and the optimal adsorption time was 6 h and the optimal pH was 6. The results of the kinetic model studies showed that Mn(II) removal by M-MWCNTs followed the pseudo-second-order model. Isothermal studies were conducted and the results demonstrated that the experimental data fitted well with the three models. The reliability of the experimental results was well verified by PSO-BP simulation, and the present conclusion could be used as a condition for further simulation. The research results provide a potential technology for promoting the removal of manganese from wastewater; at the same time, the application of various mathematical models also provides more scientific ideas for the research of the mechanism of adsorption of heavy metals by nanomaterials.


Assuntos
Metais Pesados , Nanotubos de Carbono , Poluentes Químicos da Água , Nanotubos de Carbono/química , Reprodutibilidade dos Testes , Concentração de Íons de Hidrogênio , Manganês , Adsorção , Cinética
20.
Molecules ; 28(12)2023 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-37375292

RESUMO

CNTs/Fe-BTC composite materials were synthesized with the one-step solvothermal method. MWCNTs and SWCNTs were incorporated in situ during synthesis. The composite materials were characterized by different analytical techniques and used in the CO2-photocatalytic reduction to value-added products and clean fuels. In the incorporation of CNTs into Fe-BTC, better physical-chemical and optical properties were observed compared to Fe-BTC pristine. SEM images showed that CNTs were incorporated into the porous structure of Fe-BTC, indicating the synergy between them. Fe-BTC pristine showed to be selective to ethanol and methanol; although, it was more selective to ethanol. However, the incorporation of small amounts of CNTs into Fe-BTC not only showed higher production rates but changes in the selectivity compared with the Fe-BTC pristine were also observed. It is important to mention that the incorporation of CNTs into MOF Fe-BTC allowed for increasing the mobility of electrons, decreasing the recombination of charge carriers (electron/hole), and increasing the photocatalytic activity. In both reaction systems (batch and continuous), composite materials showed to be selective towards methanol and ethanol; however, in the continuous system, lower production rates were observed due to the decrease in the residence time compared to the batch system. Therefore, these composite materials are very promising systems to convert CO2 to clean fuels that could replace fossil fuels soon.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA