Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 495
Filtrar
1.
Int Orthop ; 48(3): 693-698, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37770674

RESUMO

BACKGROUND: Metal allergy remains a controversial topic in the orthopaedic community. It is not known if or to what degree metal sensitivity contributes to inflammatory soft tissue failures, unexplained residual pain, or clinical complications after total joint replacement with metal prostheses. METHODS: We investigated the efficacy of the lymphocyte transformation test (LTT) in predicting adverse outcomes in patients after receiving a metal joint replacement. Our study cohort consists of 135 metal-on-metal hip resurfacing arthroplasty cases performed between 2013 and 2015. All study patients had an LTT preoperatively. We retrospectively analyzed clinical outcomes and failures for our cohort. RESULTS: There was no difference in LTT reactivity between men and women. Of the 135 patients tested, 46 (34.1% of cohort) tested positive to at least one of the materials comprising their implant, and 78 patients (57.8%) had at least one reactive score to any component of the LTT. After a minimum follow-up of two years, we did not observe an allergic response to the implant in any patients. There were no failures requiring revision. We observed a 2.2% rate of moderate residual pain; no patients with residual pain tested positive for metal sensitivity. When patients with moderate-high LTT reactivity (30.4% of cohort) were compared to the remainder of the study group, there was no difference in HHS or UCLA activity score. There was no correlation between blood metal ion levels and LTT reactivity. CONCLUSION: We were unable to prove any predictive value of the LTT. We failed to identify hypersensitivity to metals in patients with metal-on-metal hip resurfacing arthroplasty.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Hipersensibilidade , Próteses Articulares Metal-Metal , Masculino , Humanos , Feminino , Artroplastia de Quadril/efeitos adversos , Estudos Prospectivos , Estudos Retrospectivos , Próteses Articulares Metal-Metal/efeitos adversos , Ativação Linfocitária , Metais/efeitos adversos , Hipersensibilidade/epidemiologia , Hipersensibilidade/etiologia , Dor/etiologia , Prótese de Quadril/efeitos adversos
2.
Arch Orthop Trauma Surg ; 143(3): 1217-1221, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34724103

RESUMO

INTRODUCTION: Increased cobalt (Co) and chromium (Cr) serum levels are one reason for revision surgery in metal on metal (MoM) total hip arthroplasty (THA) patients. Dual mobility liners are a simple revision option; however, they preserve the metal shell and stem and it is therefore not clear if metal ion levels will fully normalize after revision surgery. MATERIAL AND METHODS: Between April 2013 and December 2017 25 hips (24 patients) underwent revision from a MoM THA to an off-label dual mobility liner. Five patients were lost to follow-up and one patient refused leaving 18 patients (11 men, 7 female, average age 63.9 years) for pre- and postoperative metal ion level blood tests at a minimum follow-up of 2 years. RESULTS: Fourteen patients were revised for osteolysis, two for elevated metal ion levels and two for fluid or cysts around the femoral or acetabular component. The average preoperative Co and Cr levels were 8.3 µg/l and 5.0 µg/l, respectively. At a minimum follow-up of 2 years (30-95 months), metal ions dropped to 0.8 µg/l. Harris Hip Score (HHS), Hip Osteoarthritis Outcome Score (HOOS), Visual Analog Scale (VAS) and the UCLA activity score improved non-significantly from pre- to postoperative. There was one postoperative complication in the study cohort. One patient with persisting pain required revision surgery to a standard acetabular component during the follow-up period. CONCLUSION: The off-label use of a dual-mobility liner in the current study resulted in normalization of the metal ion levels suggesting that preserving the cobalt-chromium acetabular component has little impact on ion levels. In addition, dual mobility liners have a low complication and revision rate.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Cobalto , Cromo , Desenho de Prótese , Metais , Íons , Reoperação , Seguimentos
3.
Arch Orthop Trauma Surg ; 143(7): 4437-4446, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36197490

RESUMO

INTRODUCTION: The aim of this retrospective study was to study the long-term survival and reasons for revisions of a single-type, large-diameter head (LDH) metal-on-metal (MoM) implant. A special study interest was to find the threshold level for revision in terms of adverse reaction to metal debris (ARMD). MATERIALS AND METHODS: In this cohort study, we retrospectively reviewed 234 patients (253 hips) who received 38 mm head size LDH MoM total hip arthroplasties (THAs) between 01 January 2004 and 31 December 2009 at our institution. Patient symptoms, conventional radiographs, magnetic resonance imaging (MRI) findings and whole blood metal ions were studied. RESULTS: The median follow-up time was 11.5 years. The Kaplan-Meier cumulative survival estimate of the implant was 89.6% at 10 years and 82.9% at 14.6 years. Overall, 34/253 (13.4%) hips were revised during the follow-up period and of these; 19/34 (55.9%) were revised due to ARMD. The prevalence of ARMD was 12.4% (29/234 patients). CONCLUSIONS: The survival of the implant was on a moderate level as the 10-year cumulative survival rate was 89.6%. The exact threshold level for ARMD revision cannot be determined due to multiple variables affecting factors in re-operation decision-making.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Humanos , Artroplastia de Quadril/efeitos adversos , Estudos Retrospectivos , Prótese de Quadril/efeitos adversos , Estudos de Coortes , Próteses Articulares Metal-Metal/efeitos adversos , Desenho de Prótese , Metais/efeitos adversos , Reoperação , Estimativa de Kaplan-Meier , Falha de Prótese
4.
Arch Orthop Trauma Surg ; 143(9): 5967-5976, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36802238

RESUMO

BACKGROUND: Pseudotumors and muscle atrophy have been associated with metal-on-metal (MoM) resurfacing hip arthroplasty (RHA). We aimed to investigate the influence of the anterolateral (AntLat) and the posterior (Post) surgical approach on the location, grade and prevalence of pseudotumors and muscle atrophy in MoM RHA. PATIENTS AND METHODS: Forty-nine patients were randomized to MoM RHA by the AntLat (n = 25) or the Post (n = 24) approach at Aarhus University Hospital. Patients underwent metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) scans for investigation of location, grade and prevalence of pseudotumors and muscle atrophy. Plain radiographs, metal-ions concentrations and clinical outcome scores were evaluated to compare outcomes of the surgical approaches. RESULTS: MRI-detected pseudotumors were seen in 7 of 18 patients (39%) in the AntLat group and in 12 of 22 patients (55%) in the Post group (p = 0.33). Pseudotumors were mainly located anterolaterally to the hip joint in the AntLat group and postero-lateral to the hip joint in the Post group. Higher grades of muscle atrophy of the caudal part of the gluteus medius and minimus (p < 0.004) were seen in the AntLat group, and higher grades of muscle atrophy of the small external rotators were seen in the Post group (p < 0.001). The AntLat group had higher anteversion angles of mean 15.3° (range 6.1-7.5) versus mean 11.5° (range 4.9-22.5) in the Post group (p = 0.02). Metal-ion concentrations and clinical outcome scores were similar between groups (p > 0.08). CONCLUSION: Muscle atrophy and pseudotumor location after MoM RHA follow the surgical approach used for implantation. This knowledge may help differentiate between "normal postoperative appearance" and "MoM disease."


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Metais , Imageamento por Ressonância Magnética/métodos , Atrofia Muscular/diagnóstico por imagem , Atrofia Muscular/etiologia , Desenho de Prótese , Cobalto
5.
Eur J Orthop Surg Traumatol ; 33(7): 3089-3097, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37017738

RESUMO

PURPOSE: Growing number of hip arthroplasty in Poland performed with the use of metaphyseal stems results from the decreasing age of patients qualified for procedures and is consistent with the corresponding trends in European countries. To this day, a significant population functions after undergoing hip replacement using metal-on-metal implant. This study was aimed at the assessment of the variability of the oxidative system, as well as the concentrations of chromium and cobalt ions in serum and blood and their potential impact on postoperative clinical status. MATERIAL AND METHODS: The analysis included 58 men. The first group-operated using J&J DePuy ASR metal-on-metal implant with metaphyseal stem ProximaTm. Second group-operated using K-Implant SPIRON® femoral neck prosthesis in full ceramic articulation. Selected parameters of oxidative stress and the antioxidant system as well as the concentration of metal ions in blood were determined twice. Each patient underwent two clinical evaluations using acclaimed physical examination scale systems. RESULTS: In the first group, significantly higher concentrations of Cr (p = 0.028) and Co (p = 0.002) were demonstrated compared to the group of femoral neck arthroplasty. The mean concentrations of Cr and Co, 10.45 and 9.26 µg/l, respectively, were higher in patients operated bilaterally. In the ASR group, greater pain intensity in the operated hip and higher indicators of oxidative stress were found. CONCLUSIONS: Metal-on-metal articulation of the hip significantly increases the concentration of Cr and Co in blood, induces oxidative stress and modifies function of the antioxidant system and generates greater pain in the operated hip.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Masculino , Humanos , Prótese de Quadril/efeitos adversos , Colo do Fêmur , Antioxidantes , Próteses Articulares Metal-Metal/efeitos adversos , Desenho de Prótese , Metais , Artroplastia de Quadril/efeitos adversos , Cobalto , Cromo , Cerâmica , Íons , Estresse Oxidativo
6.
Skeletal Radiol ; 51(11): 2105-2120, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35624311

RESUMO

The purpose of this article is to describe the use of ultrasound for the diagnosis and treatment of painful joint arthroplasty. Ultrasound plays a crucial role in the diagnosis of the painful joint arthroplasty, especially given its unique dynamic capabilities, convenience, and high resolution. Ultrasound guidance is also instrumental for procedures in both diagnosing and in select cases, treating the painful joint arthroplasty. Topics to be discussed in this article include trends in arthroplasty placement, benefits of the use of ultrasound overall, and ultrasound evaluation of periprosthetic joint infections. We will also review the sonographic findings with dissociated/displaced components and adverse reaction to metallic debris including metallosis, trunnionosis, and metal-on-metal pseudotumors. Additionally, we will discuss ultrasound evaluation of tendon pathologies with arthroplasties, including dynamic maneuvers to evaluate for tendon impingement/snapping. Finally, we will cover ultrasound-guided joint arthroplasty injection indications and precautions. KEY POINTS: • Ultrasound is preferred over MRI in patients with joint arthroplasty and plays a crucial role in diagnosis, especially given its unique dynamic capabilities, convenience and high resolution. • It is especially beneficial for US-guided aspiration in periprosthetic joint infections; effectively used to evaluate periprosthetic fluid collections, facilitating differentiation between abscesses and aseptic collections, and tracking sinus tracts. • Recently, the diagnosis of periprosthetic joint infections has shifted focus to biomarkers in the periprosthetic fluid, specifically α-defensin, which has a high sensitivity and specificity for diagnosing infection. • Cutibacterium acnes is a major pathogen responsible for shoulder arthroplasty infections, often presenting with normal laboratory values and since slow growing, must be kept for a minimum of 14 days.


Assuntos
Artrite Infecciosa , Artroplastia de Quadril , Infecções Relacionadas à Prótese , Artralgia/etiologia , Artrite Infecciosa/diagnóstico , Artroplastia de Quadril/métodos , Biomarcadores , Humanos , Estudos Prospectivos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Sensibilidade e Especificidade , Líquido Sinovial
7.
J Arthroplasty ; 37(7S): S560-S565, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35219576

RESUMO

BACKGROUND: Use of metal-on-metal (MoM) articulations in total hip arthroplasty (THA) has sharply declined due to high failure rates from metal-related complications. Although certain MoM designs have demonstrated only 46% survival, not all MoM designs have performed the same. The purpose of this study is to evaluate mid-term to long-term survival of a specific MoM implant with a modular titanium taper adapter. METHODS: A retrospective review was performed on all patients who underwent primary THA at our center with the M2a-Magnum system (Zimmer Biomet, Warsaw, IN). Of 829 patients (956 hips) identified, 754 patients (869 hips) met inclusion criteria of signed research consent, minimum 2-year follow-up, and/or any revision surgery. RESULTS: Mean follow-up was 11.0 years (range 2-16; ±3.5). Mean cup angle of inclination was 42.8° (range 24°-70°, ±6.3°), with 88.0% reconstructed within the 40° ± 10° safe zone. There were 64 revisions (7.36%): 7 (0.81%) septic and 57 (6.56%) aseptic. Of those, 32 (3.68%) were adverse reactions to metal debris. Kaplan-Meier survival free of revision for all causes was 88.6% at 16 years (95% confidence interval 86.8-90.4). Univariate analysis of risk factors for all-cause, aseptic, and adverse reaction to metal debris revision found no relationship with female gender, age ≥65 years, body mass index >30 kg/m2, higher activity level, or inclination angle outlier. CONCLUSION: The results of this study demonstrate a more favorable mid-term to long-term survivorship with this specific MoM implant compared to other designs. Although our institution no longer performs MoM THA, further investigation into differences in MoM implant designs is warranted.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Idoso , Artroplastia de Quadril/efeitos adversos , Feminino , Prótese de Quadril/efeitos adversos , Humanos , Próteses Articulares Metal-Metal/efeitos adversos , Metais , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Sobrevivência , Titânio
8.
J Arthroplasty ; 37(9): 1799-1808, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35429614

RESUMO

BACKGROUND: Metal-on-metal hip resurfacing is an alternative to total hip arthroplasty (THA). The aim of this study was to determine implant survivorship, analyze patient-reported outcomes measures and to determine patient satisfaction for patients who underwent metal-on-metal hip resurfacing at a large US academic institution by a single surgeon with a minimum of 10-year follow-up. METHODS: Patients who underwent hip resurfacing from September 2006 through November 2009 were included. Patient demographics and variables were collected from a prospectively maintained institutional database and patients completed an additional questionnaire with patient-reported outcomes measures. RESULTS: A total of 350 patients (389 hips) out of 371 (433 hips) with a minimum 10-year follow-up were successfully contacted (94.3% follow-up). Mean age was 53 years, 258 were male (73%). 377 out of 389 hips (96.9%) did not require additional surgery. Gender was significantly related to implant survivorship (males 99.0%, females 90.9%; P < .001). 330 patients (369 hips, 94.8%) were satisfied with their surgery. Males had higher proportion of satisfaction scores (P = .02) and higher modified Harris Hip Score (odds ratio = 2.63 (1.39, 4.98), P = .003). Median modified Harris Hip Score score for non-revised hips was 84.0 [80.0; 86.0] versus those requiring revision, 81.5 [74.0; 83.0], (P = .009). CONCLUSION: At a minimum 10-year follow-up, hip resurfacing, using an implant with a good track record, demonstrates 99.0% survivorship in male patients with an average age of 52 years. We believe that the continued use of metal-on-metal hip resurfacing arthroplasty in this population is justified by both positive patient reported outcomes and survivorship.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Cirurgiões , Feminino , Seguimentos , Articulação do Quadril/cirurgia , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Falha de Prótese , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
9.
Arch Orthop Trauma Surg ; 142(12): 4025-4032, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34846589

RESUMO

BACKGROUND: Preliminary results of metal-on-metal (MoM) hip arthroplasty were satisfactory, but since 2004 data showed high failure rates. National joint replacement registries are multi-centre databases comprised of thousands of subjects and implants which allow for identifying variables predictive of implant failure. The aim of the current study was to estimate re-revision rates after revision of a primary MoM hip arthroplasty in the Dutch Arthroplasty Register (LROI) and to assess potential predictor variables of re-revision of these MoM hip arthroplasties. METHODS: Eligible procedures were those with a revision for any reason except infection, after an initial primary surgery with a hip resurfacing (HRA) or large-head MoM (LH-MoM) total hip arthroplasty (THA). The probability of re-revision for both types of MoM hip arthroplasty over time was estimated using the cumulative incidence function taking mortality as a competing risk into account. A proportional sub-distribution hazards regression model was used to assess potential predictor variables of re-revision of these MoM hip arthroplasties. RESULTS: A total of 3476 records of revised implants were included, of which 873 (25.2%) were MoM implants. Over the course of follow-up, 101 (11.5%) MoM implants were re-revised. During follow-up 36 (4.3%) patients who received a MoM-implant at primary arthroplasty and a revision afterwards had died. The regression model showed that for primary MoM implants a MoM articulation after revision (HR 2.48; 95% CI 1.53-4.03, p < 0.001), femoral-only revisions (HR 3.20; 95% CI 2.06-4.99, p < 0.001) and periprosthetic fractures (HR 1.98; 95% CI 1.03-3.82, p = 0.042) as reason for the first revision were statistically significant risk factors for re-revision. CONCLUSION: Both types of large-head MoM hip arthroplasties have shown high revision and re-revision rates; risk factors were identified. The outcome of this study can be helpful in managing expectations of patients and orthopaedic surgeons.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Humanos , Próteses Articulares Metal-Metal/efeitos adversos , Prótese de Quadril/efeitos adversos , Falha de Prótese , Desenho de Prótese , Reoperação/métodos , Artroplastia de Quadril/efeitos adversos , Metais , Fatores de Risco , Sistema de Registros , Resultado do Tratamento
10.
Arch Orthop Trauma Surg ; 142(10): 2577-2583, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33837474

RESUMO

INTRODUCTION: Recalls of total hip arthroplasty (THA) implants, including metal-on-metal (MoM) THA and dual taper stems, due to increased risk of adverse local tissue reaction (ALTR), represent a challenge for both surgeons and patients. This study aims to analyze the revision surgery outcomes for ALTR in patients with recalled THA implants. METHODS: A total of 118 consecutive patients who underwent revision surgery due to ALTR with recalled THA were analyzed. Sub-group analysis was performed for recalled MoM THAs, head-neck modular stems, and dual taper neck-stems. RESULTS: At a mean follow-up of 6.6 years, the complication and reoperation rates of the recalled THAs were 32.2% and 25.4% respectively. The most common post-revision complication was dislocation (16%). Revision of modular taper corrosion THA and high-grade intraoperative tissue damage were risk factors associated with post-revision complications. CONCLUSION: This study reports high complication and reoperation rates of recalled THAs at mid-term follow-up. The high revision surgery complication rates in both groups suggest the importance of a systematic evaluation of all THA patients with at-risk implants. LEVEL OF EVIDENCE: Level III, case control retrospective analysis.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto , Prótese de Quadril/efeitos adversos , Humanos , Próteses Articulares Metal-Metal/efeitos adversos , Metais , Desenho de Prótese , Falha de Prótese , Reoperação/efeitos adversos , Estudos Retrospectivos
11.
AJR Am J Roentgenol ; 216(2): 311-317, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33325734

RESUMO

OBJECTIVE. Metal-on-metal hip arthroplasty has been shown to result in soft-tissue complications in some patients, making revision surgery necessary. Imaging is critical in the detection and surveillance of soft-tissue complications, which are collectively termed adverse reaction to metal debris (ARMD) and adverse local tissue reaction. Studies have investigated the use of ultrasound, MRI, and CT for detecting ARMD, and each modality has advantages and disadvantages. This article provides evidence-based recommendations for imaging surveillance of ARMD. CONCLUSION. Compared with ultrasound, MRI has been found to be a better imaging modality for surveillance of ARMD. In addition, MRI is not operator dependent, allows visualization of soft-tissue details, and allows more consistent measurement of fluid collections on follow-up examinations. Limitations of ultrasound include operator skill, the inability to visualize osseous structures, and the challenge of visualizing posterior soft tissues for synovitis and fluid collections in larger patients. Finally, CT is only useful for focused evaluation of osteolysis or periprosthetic fracture.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril/efeitos adversos , Próteses Articulares Metal-Metal/efeitos adversos , Complicações Pós-Operatórias/diagnóstico por imagem , Idoso , Artroplastia de Quadril/efeitos adversos , Feminino , Humanos , Imageamento por Ressonância Magnética , Complicações Pós-Operatórias/etiologia , Falha de Prótese , Tomografia Computadorizada por Raios X , Ultrassonografia
12.
BMC Musculoskelet Disord ; 22(1): 400, 2021 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-33941155

RESUMO

BACKGROUND: The high failure rates of metal on metal (MoM) large diameter head total hip arthroplasty (LDH THA) and hip resurfacing (HR) prevented their long-term comparisons with regards to clinical outcome. Such knowledge would be important as ceramic LDH bearing is now available. With long-term follow-up, we investigated the difference in 1) patient-reported outcome measures (PROMs); 2) revision and adverse events rates, and 3) metal ion levels between MoM LDH THA and HR. METHODS: Forty-eight patients were randomized for LDH THA (24) or HR (24) with the same MoM articulation. At a mean follow-up of 14 years, we compared between groups different PROMs, the number of revisions and adverse events, whole blood Cobalt (Co) and Chromium (Cr) ion levels, and radiographic signs of implant dysfunction. RESULTS: LDH THA (all cases: revised and well-functioning) had significantly better WOMAC (94 versus 85, p = 0.04), and more frequently reported having no limitation (p = 0.04). LDH THA revision rate was 20.8% (5/24) versus 8.3% (2/24) for HR (p = 0.4). Mean Co and Cr ion levels were higher in LDH THA compared to the HR (Co: 3.8 µg/L vs 1.7 µg/L; p = 0.04 and Cr: 1.9 µg/L vs 1.4 µg/L, p = 0.1). On radiographic analyses, 2 LDH THAs showed signs of adverse reaction to metal debris, whereas 1 loose femoral HR component was documented. CONCLUSION: In the long-term, MoM LDH THA had a high trunnion related revision rate but nonetheless showed better PROMs compared to HR. Provided with a well-functioning modular junction, non-MoM LDH THA would offer an appealing option. TRIAL REGISTRATION: ClinicalTrials.gov ( NCT04516239 ), August 18, 2020. Retrospectively registered.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto , Prótese de Quadril/efeitos adversos , Humanos , Desenho de Prótese , Reoperação
13.
Int J Audiol ; 60(1): 44-53, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32687006

RESUMO

OBJECTIVE: This study aimed to systematically investigate the ototoxic potential of cobalt in patients with a metal-on-metal (MoM) hip implant, using objective auditory and vestibular assessments and a questionnaire. The results of the objective evaluation were published previously, whereas the current study focused on the questionnaire outcome and its relationship to the blood cobalt level. Design and study sample: Twenty patients (33-65 years) with a primary MoM hip implant and 20 non-implanted control subjects, matched for age, gender, and noise exposure, received a questionnaire to evaluate the presence of several hearing and balance symptoms (part 1) and general neurological issues (part 2). RESULTS: Concerning part 1, the proportion of auditory-related symptoms in general (p = 0.022) and tinnitus (p = 0.047) was significantly higher in the MoM patient group, whereas no group difference was found for hyperacusis, increased listening effort, and decreased speech understanding. Concerning part 2, no significant group differences were detected. Within the MoM patient group, the questionnaire outcome was not significantly different between the low-exposure and high-exposure subgroups according to the blood Co level. CONCLUSIONS: In line with our previous study, these results potentially imply Co-induced impairment to the auditory system, despite the lack of a clear dose-response relationship.


Assuntos
Artroplastia de Quadril , Próteses Articulares Metal-Metal , Cobalto/toxicidade , Humanos , Medidas de Resultados Relatados pelo Paciente , Projetos Piloto , Desenho de Prótese
14.
J Arthroplasty ; 36(2): 616-622, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32896438

RESUMO

BACKGROUND: We assessed the survivorship of a proximally hydroxyapatite coated, double tapered, titanium-alloy femoral stem in a single center, at an average follow up of 12.5 years (10.1-15.8). The majority of stems were inserted as part of a Metal on Metal (MoM) Total Hip Replacement (THR). METHODS: Data was collected prospectively in a local database. A retrospective review was performed of all patients undergoing a primary THR with the prosthesis between 2003 and 2010. Primary outcome was revision of the stem for any cause. Analysis was also performed for stem revision for aseptic loosening, stem revision in the MoM setting and a worst case scenario whereby lost to follow up were presumed to have failed. True stem failure was considered if revision occurred for a stem related complication. RESULTS: 1465 stems were included (1310 patients, 155 bilateral). The bearing surface was cobalt chrome on cobalt chrome in 1351 cases (92%). Seven hips were lost to follow up. Thirty-two stems (31 part of a MoM THR) underwent revision for any cause. Kaplan Meier survival analysis demonstrates an overall 97.4% survivorship. Subset analysis demonstrates 100% survivorship for aseptic loosening, 97.3% in the MoM setting and 96.7% for the worst case senario. Of the 32 cases of stem revision, only 13 were classified as 'true' stem failure. CONCLUSION: This study represents the largest cohort of this uncemented femoral component with a minimum follow-up longer than 10 years. Our results demonstrate excellent long-term survivorship even in the presence of a challenging MoM environment.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Ligas , Artroplastia de Quadril/efeitos adversos , Durapatita , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Titânio , Resultado do Tratamento
15.
J Arthroplasty ; 36(4): 1380-1387, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33189496

RESUMO

BACKGROUND: To our knowledge, this is the largest single-center cohort of the 36-mm Corail-Pinnacle metal-on-metal total hip replacements system, aiming to determine 10-year survivorship and identify predictors of revision. We further assessed year of implantation given reports of manufacturing variations affecting shells made after 2006 predisposing these components to increasing wear. METHODS: All Corail-Pinnacle 36-mm metal-on-metal hips implanted in a single center (2005-2012). The effect of patient and implant-related variables, and year of implantation on revision risk was assessed using Kaplan-Meier, Cox regression, and interrupted time series analysis. RESULTS: In total, 1212 metal-on-metal total hip replacements were implanted with a 10-year survival rate of 83.4% (95% confidence interval [CI] = 81.3-85.5). Mean follow-up duration was 7.3 years with 61% of patients reaching a minimum of 7 years of follow-up. One hundred nineteen patients required revision surgery (9.8%). Univariate analysis identified female gender (hazard ratio [HR] = 1.608, CI = 1.093-2.364, P = .016), age at implantation (HR = 0.982, CI = 0.968-0.997, P = .019), smaller 50-mm to 54-mm cup diameter (HR = 1.527, CI = 1.026-2.274, P = .037), and high-offset stems (HR = 2.573, CI = 1.619-4.089, P < .001) as predictors of revision. Multivariate modeling confirmed female gender and high-offset stems as significant predictors of revision. For components implanted after 2007, the number of revisions showed no statistically significant step increase compared to pre-2007 implantation. CONCLUSION: We observed a high 10-year failure rate (16.6%) with this implant, mostly due to adverse reaction to metal debris. Female gender and high femoral offset stems were significant predictors for all-cause revision. Year of implantation was not significantly associated with an increasing number of revisions from 2007 onwards, although further studies to validate the impact of manufacturing discrepancies are recommended.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Estudos de Coortes , Feminino , Prótese de Quadril/efeitos adversos , Humanos , Próteses Articulares Metal-Metal/efeitos adversos , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Risco , Sobrevivência
16.
J Arthroplasty ; 36(6): 2080-2086, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33612330

RESUMO

BACKGROUND: Long-term survival of metal-on-metal (MoM) prostheses and the development of adverse reaction to metal debris (ARMD) around these bearings are still unclear. Serum levels of cobalt (Co) and chromium (Cr) are used as a screening tool to anticipate failure in MoM bearings and detect ARMD. METHODS: One hundred sixty primary large head MoM prostheses were followed up for 10 years. To estimate the revision risk, the cumulative incidence function (CIF) was used. Subdistribution hazard modeling was used to investigate the associations between cumulative incidence of revision for ARMD and Co levels, Cr levels, gender, age, head size, and cup inclination. Furthermore, the safe upper limits (SULs) for Co and Cr were determined. RESULTS: Univariate analyses showed an increased risk in revision for ARMD in females (subdistribution hazard ratio [sdHR] 3.43, 95% confidence interval [CI] 1.01-11.7, P = .049) and cup inclination angles over 45° (sdHR 4.70, 95% CI 1.63-13.58, P = .004). In addition, a higher last measured Co level (sdHR 1.05, 95% CI 1.03-1.07, P < .001) and last measured Cr level (sdHR 1.21, 95% CI 1.14-1.29, P < .001) were associated with a higher probability of revision for ARMD. We determined our bearing-specific SULs at 4.1 parts per billion (ppb) and 4.2 ppb for Co and Cr, respectively. CONCLUSION: Guidelines regarding follow-up and surveillance should include a complete clinical assessment with bearing-specific SULs of serum metal ion levels. For the M2a-Magnum MoM bearing we advise an SUL for Co and Cr levels of 4.1 and 4.2 ppb, respectively.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Cromo , Cobalto , Feminino , Seguimentos , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação
17.
J Arthroplasty ; 36(10): 3490-3497, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34172347

RESUMO

BACKGROUND: This study examines cobalt levels and pseudotumor characteristics in a non-recalled modular femoral prosthesis. We sought to determine relationships between serum cobalt levels and pseudotumors following modular and metal-on-metal (MoM) total hip arthroplasty (THA), the location and size of pseudotumors, and changes to pseudotumor grade over time. METHODS: We retrospectively evaluated a cohort of 190 primary THAs implanted with a dual-modular femoral stem by one surgeon from 2005 to 2013. One hundred seventeen THAs used a cobalt-chromium modular neck (CoCrMN) component and non-MoM articulation, 63 THAs had a titanium neck component and MoM articulation, and 10 had a titanium neck component and polyethylene liner. Serum ion levels were recorded for all patients. Pseudotumor grade and location were measured by musculoskeletal-trained radiologists. RESULTS: Cobalt levels did not correlate to time after index arthroplasty. In the CoCrMN group, cobalt levels were elevated in 11 of 19 (57.9%) patients with pseudotumor compared to 14 of 19 (73.7%) in the MoM group. Pseudotumors were more often located lateral to the hip joint in the CoCrMN group compared to anteromedial following MoM arthroplasty. In CoCrMN THAs, pseudotumors were visualized in 12 of 51 (23.5%) initial MARS MRIs within 40 months compared to 5 of 66 (7.6%) performed later (P = .02). CONCLUSION: Pseudotumor characteristics differ between patients with CoCrMN designs vs those with an MoM articulation. Normal serum cobalt levels did not exclude the presence of a pseudotumor and routine MARS MRI should be included in follow-up of patients with this CoCrMN prostheses.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto , Colo do Fêmur , Prótese de Quadril/efeitos adversos , Humanos , Próteses Articulares Metal-Metal/efeitos adversos , Desenho de Prótese , Estudos Retrospectivos
18.
J Arthroplasty ; 36(9): 3312-3317.e1, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34030874

RESUMO

BACKGROUND: Adverse local tissue reactions (ALTR) are associated with total hip arthroplasty (THA) failure in patients with metal-on-metal bearings and/or taper corrosion, which can also occur in metal-on-polyethylene articulations. Patients are monitored with blood cobalt (Co) and chromium (Cr) concentrations which do not always correlate with the degree of soft tissue reaction at revision THA. The purpose of this study was to determine how the blood and prosthetic hip synovial fluid levels of Co and Cr correlate with one another, and determine which concentration is more predictive of ALTR. METHODS: Synovial fluid and blood samples were collected at the time of revision THA in patients with (n = 26) and without ALTR (n = 27). Whole blood, serum, and synovial fluid metal ion concentrations were correlated with one another and clinical findings. RESULTS: The ratio of synovial fluid to whole blood Co concentration in ALTR and non-ALTR hips was 120:1 and 18:1 (P = .006). The mean ratio of synovial fluid to whole blood Cr concentration in ALTR and non-ALTR hips was 414:1 and 24:1 (P = .01). The mean synovial fluid Co/Cr concentrations were elevated in patients with ALTR compared with those without (2007.3 vs. 12.4 ppb, P = .007) and (3188.2 vs. 10.3 ppb, P = .02). The synovial fluid Co concentration was the most accurate test for detecting ALTR (cut off: 19.75 PPB, AUC 0.973). CONCLUSION: In patients with ALTR, synovial fluid Co and Cr levels were 120 times higher and 414 times higher than whole blood Co and Cr levels. Synovial fluid Co ion concentration was the most accurate in predicting ALTR. LEVEL OF EVIDENCE: Diagnostic level II.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto , Prótese de Quadril/efeitos adversos , Humanos , Próteses Articulares Metal-Metal/efeitos adversos , Desenho de Prótese , Falha de Prótese , Reoperação , Líquido Sinovial
19.
J Arthroplasty ; 36(9): 3200-3208, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33992480

RESUMO

BACKGROUND: Purpose of this study was to determine implant survivorship and resultant outcomes, including modes of failure, for metal-on-metal hip resurfacing through the Hueter anterior approach (HAA). METHODS: Retrospective review of cases from 2006 to 2015, resulted in 555 metal-on-metal hip resurfacing via HAA, mean age 49.4 ± 6.9 years and mean BMI 28.1 ± 5.3. Kaplan-Meier curves were used to assess implant survivorship. Evaluation of technique was based on radiographic assessment of component position at 6 weeks. Patient-reported outcome measures were assessed using 12-Item Short Form Survey 12, University of California Los Angeles activity, Western Ontario and McMaster Universities Osteoarthritis Index, and hip disability osteoarthritis outcome scores. RESULTS: At a mean follow-up of 9.18 years, survivorship was 95.0% at 5 years (95% CI: 93.2-96.8 years) and 92.5% at 10 years (95% CI: 90.0-95.0 years); men at 96.1% (95% CI: 94.3-97.9) and 93.8% (95% CI: 91.1-96.5), and women at 88.8% (95% CI: 81.9-95.7) and 85.6% (95% CI: 77.6-93.6), 5 and 10 years, respectively (P = .033). There were 37 revisions to total hips (7%) at a mean time of 3.3 years (SD 2.7). Indications for revision were aseptic loosening of acetabular (n = 12) and femoral component (n = 7) and pseudotumor (n = 6). Radiographic parameters were respectable and consistent, median acetabular inclination angle 41.2° and femoral stem shaft angle 137.7°. Patient-reported outcome measure scores significantly improved and remained stable at 2 and 5 years postoperatively. CONCLUSION: Although choice of surgical approach should always be based on surgeon's technical expertise, this study has shown that HAA is safe and effective for hip resurfacing. Mindful attention to long-term metal ion exposure must still be considered.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Adulto , Feminino , Seguimentos , Humanos , Masculino , Próteses Articulares Metal-Metal/efeitos adversos , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
20.
J Arthroplasty ; 36(8): 2871-2877, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33812711

RESUMO

BACKGROUND: Metal-on-metal (MOM) surfaces in total hip arthroplasty (THA) have been used widely. Serum cobalt and chromium levels have been the standard investigation for follow-up examinations, but magnetic resonance imaging (MRI) with metal artifact reducing sequences has shown good results in detecting pseudotumors. The aim of this study is to survey a significant correlation among MRI findings, serum metal levels, and clinical scores in patients with small-head MOM implants and if serum cobalt and chromium levels are sufficient in detecting patients with pseudotumors in the long-term follow-up. METHODS: At a minimum follow-up of 20 years, 26 patients (29 THAs) of the original 98 patients (105 THAs) included in this study between November 1992 and May 1994 were available for follow-up examination. Clinical scores, serum metal ion levels, and MRIs were obtained. RESULTS: We found mean serum cobalt levels of 1.87 µg/L (±3.44) and chromium levels of 2.23 µg/L (±2.96) and very good clinical and functional results (mean Harris Hip Score 88.6) in the long-term follow-up. Pseudotumors were detected in MRIs of 21 hips. There were no significant differences between patients with or without pseudotumors regarding serum metal levels and the correlation for clinical outcome scores, demographic data, and cup inclination. The cumulative rate of survival was still at 91.4% at 22.8 years. CONCLUSION: This study presents the first published data on small-head MOM hips, comparing metal ion levels, pseudotumors, clinical, and radiological results in a follow-up period of more than 20 years and reveals that serum metal levels are not significantly higher in patients with pseudotumors. LEVEL OF EVIDENCE: Therapeutic Level III.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Próteses Articulares Metal-Metal/efeitos adversos , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA