1.
J Cardiovasc Electrophysiol ; 35(3): 418-421, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38213071

RESUMO

INTRODUCTION: Patients with congenital heart disease are at increased risk for requiring cardiac pacing during their lifetime. METHODS: We present the first described case of using two leadless pacing systems manufactured by separate companies implanted within the same patient to provide atrial and ventricular pacing due to complex congenital anatomy. RESULTS: A 27-year-old male with dextrocardia with double outlet right ventricle, subaortic ventricular septal defect, and pulmonary stenosis status-post pulmonary valve replacement complicated by ventricular pacing dependence and subsequent atrial pacing dependence after atriotomy-based atypical flutter ablation developed recurrent mediastinitis and pocket infection with erosion despite prolonged antibiotic treatment. Due to atrial and ventricular pacing dependence, a comprehensive congenital care team concluded the need for lead extraction and replacement of pacemaker via leadless peacemaking device. Laser-lead extraction and temporary atrial pacemaker placement was performed. Afterward, a transesophageal echocardiogram guided implantation of both a Micra AV 2 (Medtronic) leadless pacemaker in the interventricular septum within the right ventricle and an Aveir (Abbott) leadless pacemaker in the superior base of the right atrial appendage was performed with successful pacing. Although there is no communication between these devices, atrial-mechanical ventricular pacing was reliable with good implant thresholds, impedances and sensing from both devices. CONCLUSION: Our case demonstrates the feasibility of using dual leadless pacing modalities to simultaneously pace someone at complex, prohibitive risk for temporary permanent or permanent pacemaker devices.


Assuntos
Dextrocardia , Dupla Via de Saída do Ventrículo Direito , Marca-Passo Artificial , Masculino , Humanos , Adulto , Estimulação Cardíaca Artificial/efeitos adversos , Ventrículos do Coração , Dupla Via de Saída do Ventrículo Direito/etiologia , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Desenho de Equipamento
2.
J Cardiovasc Electrophysiol ; 35(6): 1115-1120, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38534012

RESUMO

INTRODUCTION: Few studies have demonstrated a high degree of atrioventricular (AV) synchrony with a new leadless pacemaker called Micra AV. Our group previously reported a new and unique sensing method. We believe that this novel sensing method, "Simplified A3 method," might facilitate better AV synchrony than a conventional sensing method in almost all cases with Micra AV implantation. METHODS: We conducted a non-randomized retrospective study comparing the two pacing methods at two centers. From December 1, 2021 to October 31, 2022, Micra AV was implanted for 32 patients at the two centers. Twenty of the 32 patients with sinus rhythm and complete AV block were included in this study. In Group 1, the conventional setting was programmed as follows: auto A3 threshold, auto A3 window-end (WE), and auto A4 threshold turned on during hospitalization. In Group 2, the "Simplified A3 method" was programmed as follows: auto A3 threshold and auto A3WE turned off. Instead, an intentionally prolonged A3WE (850-1000 ms) and low A3 threshold (A3 signal amplitude + 0.5-1.0 m/s2) were programmed. RESULTS: Twenty patients were analyzed. In Group 2, AV synchrony (%AMVp) was significantly higher at the first outpatient clinic (63.0 ± 5.7% vs 81.0 ± 4.2%, p = .03). A3 threshold was significantly lower in Group 2 (5.9 ± 0.7 m/s2, p < .05 vs 2.3 ± 0.5 m/s2, p < .05). CONCLUSION: Our novel sensing method might be a more feasible sensing method for obtaining higher AV synchrony than the conventional algorithm.


Assuntos
Potenciais de Ação , Bloqueio Atrioventricular , Estimulação Cardíaca Artificial , Estudos de Viabilidade , Frequência Cardíaca , Marca-Passo Artificial , Humanos , Masculino , Feminino , Estimulação Cardíaca Artificial/métodos , Estudos Retrospectivos , Idoso , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/diagnóstico , Resultado do Tratamento , Desenho de Equipamento , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Fatores de Tempo , Valor Preditivo dos Testes , Nó Atrioventricular/fisiopatologia , Processamento de Sinais Assistido por Computador
3.
J Cardiovasc Electrophysiol ; 35(8): 1706-1709, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38894506

RESUMO

INTRODUCTION: Leadless pacemakers are associated with a low risk of infection, so indications for their removal are rare. One can expect that the dwell time of the device correlates with a more difficult removal, but it has not been proved so far. METHODS AND RESULTS: We present a case of a patient in whom MICRA transcatheter pacing system was successfully removed with nondedicated commercially available tools, 70 months after implantation. CONCLUSION: A successful removal of the MICRA leadless pacemaker is possible, and may be safe even many years after the device implantation, despite a lack of dedicated tools. Due to the potential risk of complications, the benefits and risks of the procedure should be weighted before making a final decision.


Assuntos
Remoção de Dispositivo , Desenho de Equipamento , Marca-Passo Artificial , Humanos , Estimulação Cardíaca Artificial , Resultado do Tratamento , Masculino , Feminino , Fatores de Tempo , Idoso de 80 Anos ou mais , Idoso
4.
Arch Microbiol ; 206(6): 244, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702412

RESUMO

Aggregatibacter actinomycetemcomitans is an opportunistic Gram-negative periodontopathogen strongly associated with periodontitis and infective endocarditis. Recent evidence suggests that periodontopathogens can influence the initiation and progression of oral squamous cell carcinoma (OSCC). Herein we aimed to investigate the effect of A. actinomycetemcomitans-derived extracellular vesicles (EVs) on OSCC cell behavior compared with EVs from periodontopathogens known to associate with carcinogenesis. EVs were isolated from: A. actinomycetemcomitans and its mutant strains lacking the cytolethal distending toxin (CDT) or lipopolysaccharide (LPS) O-antigen; Porphyromonas gingivalis; Fusobacterium nucleatum; and Parvimonas micra. The effect of EVs on primary and metastatic OSCC cells was assessed using cell proliferation, apoptosis, migration, invasion, and tubulogenesis assays. A. actinomycetemcomitans-derived EVs reduced the metastatic cancer cell proliferation, invasion, tubulogenesis, and increased apoptosis, mostly in CDT- and LPS O-antigen-dependent manner. EVs from F. nucleatum impaired the metastatic cancer cell proliferation and induced the apoptosis rates in all OSCC cell lines. EVs enhanced cancer cell migration regardless of bacterial species. In sum, this is the first study demonstrating the influence of A. actinomycetemcomitans-derived EVs on oral cancer in comparison with other periodontopathogens. Our findings revealed a potential antitumorigenic effect of these EVs on metastatic OSCC cells, which warrants further in vivo investigations.


Assuntos
Aggregatibacter actinomycetemcomitans , Apoptose , Proliferação de Células , Vesículas Extracelulares , Neoplasias Bucais , Aggregatibacter actinomycetemcomitans/genética , Vesículas Extracelulares/metabolismo , Neoplasias Bucais/microbiologia , Neoplasias Bucais/patologia , Humanos , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Movimento Celular , Fusobacterium nucleatum/fisiologia , Carcinoma de Células Escamosas/microbiologia , Carcinoma de Células Escamosas/patologia , Porphyromonas gingivalis/genética
5.
Europace ; 26(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38457487

RESUMO

AIMS: Aveir VR performance and predictors for its pacing threshold (PCT) in a real-world cohort were investigated. METHODS: Electrical measurements at various stages of an Aveir VR implant were prospectively collected. Predictors for 3-month PCT were studied. A retrospective cohort of consecutive 139 Micra implants was used to compare the PCT evolution. High PCT was defined as ≥1.5 V, using a pulse width of 0.4 ms for Aveir and 0.24 ms for Micra. Excellent PCT was defined as ≤0.5 V at the respective pulse width. RESULTS: Among the 123 consecutive Aveir VR implant attempts, 122 (99.2%) were successful. The majority were of advanced age (mean 79.7) and small body size (mean BSA 1.60). Two patients (1.6%) experienced complications, including one pericardial effusion after device reposition and one intraoperative device dislodgement. Eighty-eight patients reached a 3-month follow-up. Aveir 3-month PCT was correlated with impedance at mapping (P = 0.015), tether mode (P < 0.001), end-of-procedure (P < 0.001), and mapping PCT (P = 0.035), but not with PCTs after fixation (P > 0.05). Tether mode impedance >470 ohms had 88% sensitivity and 71% specificity in predicting excellent 3-month PCT. Although it is more common for Aveir to have high PCT at end of procedure (11.5% for Aveir and 2.2% for Micra, P = 0.004), the rate at 3 months was similar (2.3% for Aveir and 3.1% for Micra, P = 1.000). CONCLUSION: Aveir VR demonstrated satisfactory performance in this high-risk cohort. Pacing thresholds tend to improve to a greater extent than Micra after implantation. The PCT after fixation, even after a waiting period, has limited predictive value for the chronic threshold. Low-mapping PCT and high intraoperative impedance predict chronic low PCT.


Assuntos
Marca-Passo Artificial , Realidade Virtual , Humanos , Resultado do Tratamento , Estudos Retrospectivos , Desenho de Equipamento , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos
6.
Circ J ; 88(7): 1127-1134, 2024 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-38658350

RESUMO

BACKGROUND: The Micra leadless pacemaker was developed to fit inside the right ventricle, thereby reducing overall complications by 48% compared with a historical control group. The current labeling restricts implants to the femoral approach. In this article we used 3-dimensional computer models of human hearts to demonstrate why implants can be difficult in small patients and how using the jugular approach reduces these difficulties. METHODS AND RESULTS: Cardiac computed tomography scans were made of 45 pacemaker patients, 26 in the US and 19 from a single center in Japan. Dimensional measurements were taken in all 45 hearts, and these dimensions were compared between patient cohorts and between the Micra delivery tool dimension and patient heart dimensions. Hearts were smaller among patients in the Japanese than US cohort. In addition, the tool dimension exceeded heart dimensions in a larger percentage of hearts from Japanese patients. Three dimensions were identified that most likely limit navigating across the tricuspid valve to the right ventricle in smaller hearts and for which the jugular approach improved navigation. CONCLUSIONS: Although the femoral procedure today maintains an excellent safety profile and procedure experience for most global implants, this study provides the rationale as to why the jugular approach may improve the ease of the Micra implant in small hearts, namely by reducing the tortuosity of the navigation across the tricuspid valve.


Assuntos
Veias Jugulares , Marca-Passo Artificial , Humanos , Veias Jugulares/diagnóstico por imagem , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Ventrículos do Coração , Japão
7.
BMC Cardiovasc Disord ; 24(1): 10, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38166609

RESUMO

BACKGROUND: Leadless pacemakers are a recent technological advancement. It has many advantages, but there are still a few serious complications. CASE PRESENTATION: This article reports the case of a patient with an endocardial tear and dissection caused by contact with the tip of the Micra cup during surgery and summarises the relevant data. CONCLUSIONS: This case report details the occurrence and management of the incident and provides some guidance for future clinical management.


Assuntos
Marca-Passo Artificial , Humanos , Resultado do Tratamento , Desenho de Equipamento
8.
Pacing Clin Electrophysiol ; 47(4): 554-557, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-37377404

RESUMO

The strategy after battery depletion was not established in Micra leadless pacemaker system (Micra). There are still some concerns in the 2nd Micra implantation, such as the mechanical interaction between both devices. The position of the 2nd Micra should be placed apart from the 1st Micra. We present a case of 1st Micra battery depletion who successfully underwent the 2nd Micra implantation under the intracardiac echo guidance. In our case, intracardiac echo was a very effective tool for confirming the location of Micra implantation.


Assuntos
Marca-Passo Artificial , Humanos , Resultado do Tratamento , Desenho de Equipamento , Coração , Ecocardiografia
9.
Pacing Clin Electrophysiol ; 47(2): 256-259, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37208974

RESUMO

INTRODUCTION: Micra AV Transcatheter Pacing System (TPS) represents an innovative second-generation leadless pacemaker which represents an effective alternative to conventional devices in selected cases. Intrinsic malfunctions of these devices are rare, requiring sometimes their retrieval. When performed in experienced centers, this procedure is safe. CASE PRESENTATION: We describe a case of sudden battery malfunction of a Micra AV TPS, which required the extraction and the placement of a new pacing system in the right ventricle. DISCUSSION: This case, which has never been reported, highlights the need to a careful fluoroscopic evaluation and the usefulness of remote monitoring.


Assuntos
Arritmias Cardíacas , Marca-Passo Artificial , Humanos , Resultado do Tratamento , Desenho de Equipamento , Marca-Passo Artificial/efeitos adversos , Estimulação Cardíaca Artificial
10.
J Cardiovasc Electrophysiol ; 34(1): 229-230, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35946395

RESUMO

A 70-year-old woman with longstanding persistent atrial fibrillation underwent Micra leadless pacemaker implantation and atrioventricular nodal ablation. No postprocedural complications were noted. She subsequently underwent surgical mitral valve replacement 4 years later. During the surgery, Micra tine perforation of the right ventricular free wall was seen. No device revision was performed due to her asymptomatic status and stable pacemaker position/function. Pericardial effusion is a known complication of Micra implantation. The incidence of tine perforation is unknown as many patients may be asymptomatic. The clinical consequences regarding adverse events, device functionality, and explantation/extraction risk profile remain to be determined.


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Marca-Passo Artificial , Humanos , Feminino , Idoso , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Nó Atrioventricular
11.
J Cardiovasc Electrophysiol ; 34(1): 197-206, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36317470

RESUMO

INTRODUCTION: Micra atrioventricular (AV) provides leadless atrioventricular synchronous pacing by sensing atrial contraction (A4 signal). Real-world operation and reliability of AV synchrony (AVS) assessment using device data have not been described. The purposes of this study were to (1) assess the correlation between AVS and atrial mechanical sensed-ventricular pacing (AM-VP) percentages in patients with permanent high-degree AV block and (2) report on the real-world effectiveness of Micra AV. METHODS: The correlation between ECG-determined AVS in-clinic and device-collected %AM-VP was assessed using data from 40 patients with high-degree AV block enrolled in the Micra Atrial tRacking using a Ventricular AccELerometer (MARVEL) 2 study. A retrospective analysis to assess continuously-sampled %AM-VP since last session, device programming, and electrical parameters was performed using Micra AV transmissions from the Medtronic CareLink database. Patients with transmissions ≥180 days postimplant were included. RESULTS: Among the 40 MARVEL 2 AV block patients with a median %VP of 99.7%, AVS was highly correlated with AM-VP (median AVS 87.1%, median AM-VP 79.1%; R2 = 0.764, p < .001). The CareLink cohort included 4384 patients programmed to VDD mode. The mean A4 amplitude was 2.3 ± 1.8 m/s2 at implant and 2.3 ± 1.6 m/s2 at 28 weeks. In patients with %VP >90% (n = 1662), the median %AM-VP was 74.7%. For the full cohort, median %VP was 65.6% and median projected battery longevity was 10.5 years. CONCLUSION: In patients with a high pacing burden, %AM-VP provides a reasonable estimation of AVS. The first large real-world analysis of Micra AV patients with >90% VP showed stable atrial sensing over time with a median %AM-VP, a correlate of AVS, of 74.7%.


Assuntos
Fibrilação Atrial , Bloqueio Atrioventricular , Marca-Passo Artificial , Humanos , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Estudos Retrospectivos , Reprodutibilidade dos Testes , Estimulação Cardíaca Artificial
12.
Eur J Clin Microbiol Infect Dis ; 42(7): 903-906, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37133638

RESUMO

Parvimonas micra isolations are usually part of polymicrobial infections and the pathogenic role of this microrganism is still debated. We describe here a large series of hospitalized patients diagnosed with Parvimonas micra infections and discuss the clinical and therapeutic management and the outcome of these infections.


Assuntos
Firmicutes , Infecções por Bactérias Gram-Positivas , Humanos , Firmicutes/patogenicidade , Infecções por Bactérias Gram-Positivas/microbiologia
13.
Europace ; 25(10)2023 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-37906433

RESUMO

AIMS: State-of-the-art pacemaker implantation technique in infants and small children consists of pace/sense electrodes attached to the epicardium and a pulse generator in the abdominal wall with a significant rate of dysfunction during growth, mostly attributable to lead failure. In order to overcome lead-related problems, feasibility of epicardial implantation of a leadless pacemaker at the left ventricular apex in a growing animal model was studied. METHODS AND RESULTS: Ten lambs (median body weight 26.8 kg) underwent epicardial implantation of a Micra transcatheter pacing system (TPS) pacemaker (Medtronic Inc., Minneapolis, USA). Using a subxyphoid access, the Micra was introduced through a short, thick-walled tube to increase tissue contact and to prevent tilting from the epicardial surface. The Micra's proprietary delivery system was firmly pressed against the heart, while the Micra was pushed forward out of the sheath allowing the tines to stick into the left ventricular apical epimyocardium. Pacemakers were programmed to VVI 30/min mode. Pacemaker function and integrity was followed for 4 months after implantation. After implantation, median intrinsic R-wave amplitude was 5 mV [interquartile range (IQR) 2.8-7.5], and median pacing impedance was 2235 Ω (IQR 1725-2500), while the median pacing threshold was 2.13 V (IQR 1.25-2.9) at 0.24 ms. During follow-up, 6/10 animals had a significant increase in pacing threshold with loss of capture at maximum output at 0.24 ms in 2/10 animals. After 4 months, median R-wave amplitude had dropped to 2.25 mV (IQR 1.2-3.6), median pacing impedance had decreased to 595 Ω (IQR 575-645), and median pacing threshold had increased to 3.3 V (IQR 1.8-4.5) at 0.24 ms. Explantation of one device revealed deep penetration of the Micra device into the myocardium. CONCLUSION: Short-term results after epicardial implantation of the Micra TPS at the left ventricular apex in lambs were satisfying. During mid-term follow-up, however, pacing thresholds increased, resulting in loss of capture in 2/10 animals. Penetration of one device into the myocardium was of concern. The concept of epicardial leadless pacing seems very attractive, and the current shape of the Micra TPS makes the device unsuitable for epicardial placement in growing organisms.


Assuntos
Marca-Passo Artificial , Humanos , Criança , Animais , Ovinos , Resultado do Tratamento , Desenho de Equipamento , Ventrículos do Coração , Miocárdio , Estimulação Cardíaca Artificial/métodos
14.
Circ J ; 87(12): 1809-1816, 2023 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-37532552

RESUMO

BACKGROUND: The Micra leadless pacemaker has demonstrated favorable outcomes in global trials, but its real-world performance and safety in a Japan-specific population is unknown.Methods and Results: Micra Acute Performance (MAP) Japan enrolled 300 patients undergoing Micra VR leadless pacemaker implantation in 15 centers. The primary endpoint was the acute (30-day) major complication rate. The 30-day and 6-month major complication rates were compared to global Micra studies. All patients underwent successful implantation with an average follow-up of 7.23±2.83 months. Compared with previous Micra studies, Japanese patients were older, smaller, more frequently female, and had a higher pericardial effusion risk score. 11 acute major complications were reported in 10 patients for an acute complication rate of 3.33% (95% confidence interval: 1.61-6.04%), which was in line with global Micra trials. Pericardial effusion occurred in 4 patients (1.33%; 3 major, 1 minor). No procedure or device-related deaths occurred. Frailty significantly improved from baseline to follow-up as assessed by Japan Cardiovascular Health Study criteria. CONCLUSIONS: In a Japanese cohort, implantation of the Micra leadless pacemaker had a high success rate and low major complication rate. Despite the Japan cohort being older, smaller, and at higher risk, the safety and performance was in line with global Micra trials.


Assuntos
Arritmias Cardíacas , Marca-Passo Artificial , Feminino , Humanos , População do Leste Asiático , Desenho de Equipamento , Marca-Passo Artificial/efeitos adversos , Derrame Pericárdico/etiologia , Resultado do Tratamento , Masculino , Arritmias Cardíacas/terapia
15.
BMC Cardiovasc Disord ; 23(1): 601, 2023 12 08.
Artigo em Inglês | MEDLINE | ID: mdl-38066488

RESUMO

BACKGROUND: Leadless pacemaker therapy is associated with a significant reduction in lead-related complication rate compared to conventional transvenous single chamber pacemaker therapy. However, a significant complication rate of 1.2% was observed in vascular access due to the use of large delivery femoral sheath (27Fr). The aim of this study was to evaluate the effectiveness of real-time ultrasound guidance and Z suture technique in reducing total and major vascular complications in leadless pacemaker therapy. METHOD: In this study, we performed a retrospective and prospective analysis of all adverse events associated with leadless pacemaker (Micra) implantation by two operators at a single tertiary center from December 2016 to December 2018. To mitigate the risk of vascular complications, all patients underwent real-time ultrasound-guided venipuncture for vascular access, as well as the application of a Z-suture technique for hemostasis at the end of the procedure. Data were collected on implant indications, implant procedure details, complications, and follow-up information. RESULTS: In this study, 45 patients with an age range of 24 to 94 years (mean 76 ± 14 years) were recruited, with 21 (46.6%) being female. The pacing indications for the patients included atrial fibrillation (24, 53.3%), vascular (7, 15.5%), infection (9, 20%), cognitive/frailty (3, 6.6%), and occupational (2, 4.4%). The implant procedures were performed under general anesthesia in 6 (13.3%) of the cases, and under local anesthesia and sedation in 39 (86.6%) of the cases. A single deployment was achieved in 43 (95.5%) of the patients, while 2 deployments were required in 2 (4.4%) of the patients. Notably, no vascular or major complications were reported in our cohort of patients. CONCLUSIONS: The results of this observational study indicate that incorporating real-time ultrasound guidance during venipuncture and the use of a Z-suture technique significantly reduce the occurrence of both total and major vascular complications associated with the implantation of leadless pacemaker. However, more robust and larger studies are required in order to confirm these results and implications for clinical practice.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Humanos , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Resultado do Tratamento , Estudos Retrospectivos , Marca-Passo Artificial/efeitos adversos , Fibrilação Atrial/etiologia , Desenho de Equipamento
16.
Pacing Clin Electrophysiol ; 46(3): 268-270, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36269180

RESUMO

Leadless pacemaker (LPs) is a safe device and the implantation rates of this device is increasing. The device extraction and replacement are today a challenging procedures especially in case of infections, fragile and older patients or in unfavorable venous anatomy; LPs can be a valid alternative strategy in these cases. We report a case of management of a patient with multiple previous device replacements and extractions, with malfunction of transvenous pacemaker and with a fibrous membrane between the walls of the ventricular lead and the superior vena cava (SVC), who underwent a successful LP implantation.


Assuntos
Estimulação Cardíaca Artificial , Marca-Passo Artificial , Humanos , Estimulação Cardíaca Artificial/métodos , Veia Cava Superior , Lipopolissacarídeos , Resultado do Tratamento
17.
Pacing Clin Electrophysiol ; 46(9): 1085-1091, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37428941

RESUMO

BACKGROUND: Leadless pacemakers have been developed to avoid some of the complications that are associated transvenous pacemakers. Pericardial effusion is a rare complication of leadless pacemaker implantation, which may result from perforation of the delivery catheter. In this study, we describe preclinical perforation performance of an updated Micra delivery catheter. METHODS: To assess preclinical perforation performance of the updated delivery catheter, three analyses were performed. First, Finite Element Analysis (FEA) computational modeling was performed to estimate the target tissue stress during Micra delivery catheter tenting. Second, benchtop perforation forces of ovine tissue were recorded for the original and updated delivery catheters. Finally, a Monte-Carlo simulation combining human cadaveric Micra implant forces and human ventricular tissue perforation properties was performed to estimate clinical perforation performance. RESULTS: FEA modeling demonstrated a 66% reduction in target tissue stress when using the updated Micra delivery catheter (6.2 vs. 2.2 psi, Original vs. Updated Micra delivery catheter). Updated Micra delivery catheters required 20% more force to perforate porcine ventricular tissues in benchtop testing (µupd  = 26.9N vs. µorg  = 22.4N, p = .01). Monte-Carlo Simulation of catheter performance in human cadaveric tissues predicts 28.5% reduction of catheter-perforated cases with the updated delivery catheter. CONCLUSIONS: This study, using computer modelling and benchtop experimentation, has indicated that increased surface area and rounding of the updated Micra catheter tip significantly improves preclinical perforation performance. It will be important to evaluate the impact of these catheter design changes with robust registry data.


Assuntos
Marca-Passo Artificial , Humanos , Animais , Ovinos , Suínos , Resultado do Tratamento , Desenho de Equipamento , Ventrículos do Coração , Cadáver
18.
Pacing Clin Electrophysiol ; 46(8): 827-832, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37382396

RESUMO

INTRODUCTION: Leadless pacemaker (LP) is a novel pacemaker that has been proven to be effective and safe; however, the majority of LPs in previous reports were the Medtronic Micra™ VR LP. We aim to evaluate the implant efficiency and clinical performance of the Aveir™ VR LP compared to the Micra™ VR LP. METHOD: We performed a retrospective analysis in two healthcare systems (Sparrow Hospital and Ascension Health System, Michigan) in patients implanted with LPs between January 1, 2018, and April 1, 2022. The parameters were collected at implantation, 3 months and 6 months. RESULTS: A total of 67 patients were included in the study. The Micra™ VR group had shorter time in the electrophysiology lab (41 ± 12 vs. 55 ± 11.5 min, p = .008) and shorter fluoroscopic time (6.5 ± 2.2 vs. 11.5 ± 4.5 min, p < .001) compared to the Aveir™ VR group. The Aveir™ VR group had a significantly higher implant pacing threshold compared to the Micra™ VR group (0.74 ± 0.34 mA vs. 0.5 ± 0.18 mA at pulse width 0.4 ms, p < .001), but no difference was found at 3 months and 6 months. There was no significant difference in the R-wave sensing and impedance and pacing percentage at implantation, 3 months, and 6 months. Complications of the procedure were rare. The mean projected longevity of the Aveir™ VR group was longer than the Micra™ VR group (18.8 ± 4.3 vs. 7.7 ± 0.75 years, p < .001). CONCLUSION: Implantation of the Aveir™ VR required longer laboratory and fluoroscopic time, but showed longer longevity at 6 months follow-up, compare to the Micra™ VR. Complications and lead dislodgement are rare.


Assuntos
Marca-Passo Artificial , Realidade Virtual , Humanos , Estudos Retrospectivos , Lipopolissacarídeos , Desenho de Equipamento , Estimulação Cardíaca Artificial/métodos
19.
Pacing Clin Electrophysiol ; 46(1): 39-43, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35941725

RESUMO

Leadless pacemaker implantation (LPI) has fewer device complications and reduced chance of infection compared to conventional pacemakers. Dextrocardia with situs viscerum inversus (DC+SVI) is a rare condition, which seldom leads to cardiac complications. However, its presence poses a challenge to operators in cardiac procedures. LPI reports in DC patients are scarce. We report a case of LPI in a DC+SVI patient, followed by a brief but comprehensive literature review.


Assuntos
Dextrocardia , Marca-Passo Artificial , Situs Inversus , Humanos , Dextrocardia/complicações , Situs Inversus/complicações , Situs Inversus/terapia
20.
Pacing Clin Electrophysiol ; 46(12): 1455-1464, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37957879

RESUMO

BACKGROUND: Leadless pacemakers (PMs) were recently introduced to overcome lead-related complications. They showed high safety and efficacy profiles. Prospective studies assessing long-term safety on cardiac structures are still missing. OBJECTIVE: The purpose of this study was to compare the mechanical impact of Micra with conventional PM on heart function. METHODS: We conducted a non-inferiority trial in patients with an indication for single chamber ventricular pacing. Patients were 1:1 randomized to undergo implantation of either Micra or conventional monochamber ventricular pacemaker (PM). Patients underwent echocardiography at baseline, 6 and 12 months after implantation. Analysis included left ventricular ejection fraction (LVEF), global longitudinal strain (GLS) and valve function. N-terminal-pro hormone B-type natriuretic peptide (NT-pro-BNP) levels were measured at baseline and 12 months. RESULTS: Fifty-one patients (27 in Micra group and 24 in conventional group) were included. Baseline characteristics were similar for both groups. At 12 months, (1) the left ventricular function as assessed by LVEF and GLS worsened similarly in both groups (∆LVEF -10 ± 7.3% and ∆GLS +5.7 ± 6.4 in Micra group vs. -13.4 ± 9.9% and +5.2 ± 3.2 in conventional group) (p = 0.218 and 0.778, respectively), (2) the severity of tricuspid valve regurgitation was significantly lower with Micra than conventional pacing (p = 0.009) and (3) median NT-pro-BNP was lower in Micra group (970 pg/dL in Micra group versus 1394 pg/dL in conventional group, p = 0.041). CONCLUSION: Micra is non inferior to conventional PMs concerning the evolution of left ventricular function at 12-month follow-up. Our data suggest that Micra has a comparable mechanical impact on the ventricular systolic function but resulted in less valvular dysfunction.


Assuntos
Marca-Passo Artificial , Humanos , Estimulação Cardíaca Artificial/métodos , Coração , Estudos Prospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda