Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 435
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Nano Lett ; 24(8): 2465-2472, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38349857

RESUMO

The rich morphology of 2D materials grown through chemical vapor deposition (CVD), is a distinctive feature. However, understanding the complex growth of 2D crystals under practical CVD conditions remains a challenge due to various intertwined factors. Real-time monitoring is crucial to providing essential data and enabling the use of advanced tools like machine learning for unraveling these complexities. In this study, we present a custom-built miniaturized CVD system capable of observing and recording 2D MoS2 crystal growth in real time. Image processing converts the real-time footage into digital data, and machine learning algorithms (ML) unveil the significant factors influencing growth. The machine learning model successfully predicts CVD growth parameters for synthesizing ultralarge monolayer MoS2 crystals. It also demonstrates the potential to reverse engineer CVD growth parameters by analyzing the as-grown 2D crystal morphology. This interdisciplinary approach can be integrated to enhance our understanding of controlled 2D crystal synthesis through CVD.

2.
Small ; 20(26): e2307215, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38258390

RESUMO

The development of miniaturized high-throughput in situ screening platforms capable of handling the entire process of drug synthesis to final screening is essential for advancing drug discovery in the future. In this study, an approach based on combinatorial solid-phase synthesis, enabling the efficient synthesis of libraries of proteolysis targeting chimeras (PROTACs) in an array format is presented. This on-chip platform allows direct biological screening without the need for transfer steps.  UV-induced release of target molecules into individual droplets facilitates further on-chip experimentation. Utilizing a mitogen-activated protein kinase kinases (MEK1/2) degrader as a template, a series of 132 novel PROTAC-like molecules is synthesized using solid-phase Ugi reaction. These compounds are further characterized using various methods, including matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) imaging, while consuming only a few milligrams of starting materials in total. Furthermore, the feasibility of culturing cancer cells on the modified spots and quantifying the effect of MEK suppression is demonstrated. The miniaturized synthesis platform lays a foundation for high-throughput in situ biological screening of potent PROTACs for potential anticancer activity and offers the potential for accelerating the drug discovery process by integrating miniaturized synthesis and biological steps on the same array.


Assuntos
Ensaios de Triagem em Larga Escala , Proteólise , Humanos , Ensaios de Triagem em Larga Escala/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Linhagem Celular Tumoral , Miniaturização
3.
World J Urol ; 42(1): 257, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658395

RESUMO

PURPOSE: To assess the safety and efficacy of super-mini PCNL (SMP, 14 Fr) when compared to standard PCNL (sPCNL, 24-30 Fr) in the management of renal calculi of size ranging from 1.5 to 3 cm. METHODS: From February 2021 to January 2022, a total of 100 patients were randomized to either SMP group or sPCNL group in a 1:1 ratio (50 in each group) using computer-generated simple randomization. Demographic data, stone characteristics, operative times, perioperative complications, blood transfusions, postoperative drop in haemoglobin, postoperative pain, duration of hospital stay and stone-free rates were compared between the two groups. RESULTS: Mean stone volume (2.41 cm2 vs 2.61 cm2) and stone-free rates (98% vs 94%, p = 0.14) were similar in both the SMP and sPCNL groups, respectively. The SMP group had significantly longer mean operative times (51.62 ± 10.17 min vs 35.6 ± 6.8 min, p = 0.03). Intraoperative calyceal injury (1/50 vs 7/50, p = 0.42) and mean postoperative drop in haemoglobin (0.8 ± 0.7 g/dl vs 1.2 ± 0.81, p = 0.21) were lower in the SMP group, but not statistically significant. SMP group showed significantly lower mean postoperative pain VAS scores (5.4 ± 0.7 vs 5.9 ± 0.9, p = 0.03) and mean duration of hospital stay (28.38 ± 3.6 h vs 39.84 ± 3.7 h, p = 0.0001). Complications up to Clavien grade 2 were comparable, with grade ≥ 3 complications higher in the standard group, but not statistically significant. CONCLUSION: Super-mini PCNL is equally effective as standard PCNL in treating renal calculi up to 3 cm, with significantly reduced postoperative pain and duration of hospital stay and lower risk of Clavien grade ≥ 3 complications, although with higher operative times.


Assuntos
Cálculos Renais , Nefrolitotomia Percutânea , Humanos , Cálculos Renais/cirurgia , Masculino , Feminino , Pessoa de Meia-Idade , Nefrolitotomia Percutânea/métodos , Adulto , Resultado do Tratamento , Sucção/métodos , Hospitais Universitários , Hospitais de Ensino , Nefrostomia Percutânea/métodos
4.
Anal Bioanal Chem ; 416(9): 2031-2037, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37470814

RESUMO

3D printers utilize cutting-edge technologies to create three-dimensional objects and are attractive tools for engineering compact microfluidic platforms with complex architectures for chemical and biochemical analyses. 3D printing's popularity is associated with the freedom of creating intricate designs using inexpensive instrumentation, and these tools can produce miniaturized platforms in minutes, facilitating fabrication scaleup. This work discusses key challenges in producing three-dimensional microfluidic structures using currently available 3D printers, addressing considerations about printer capabilities and software limitations encountered in the design and processing of new architectures. This article further communicates the benefits of using three-dimensional structures, including the ability to scalably produce miniaturized analytical systems and the possibility of combining them with multiple processes, such as mixing, pumping, pre-concentration, and detection. Besides increasing analytical applicability, such three-dimensional architectures are important in the eventual design of commercial devices since they can decrease user interferences and reduce the volume of reagents or samples required, making assays more reliable and rapid. Moreover, this manuscript provides insights into research directions involving 3D-printed microfluidic devices. Finally, this work offers an outlook for future developments to provide and take advantage of 3D microfluidic functionality in 3D printing. Graphical abstract Creating three-dimensional microfluidic structures using 3D printing will enable key advances and novel applications in (bio)chemical analysis.

5.
J Sep Sci ; 47(5): e2300070, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38466171

RESUMO

Herein, a deep eutectic solvent (DES)-based miniaturized pressurized liquid extraction in combination with DES-based dispersive liquid-liquid microextraction (DLLME) was developed for the extraction of organophosphorus pesticides (parathion-methyl, triazophos, parathion, diazinon, and phoxim) from egg powder samples prior to their analysis by a high-performance liquid chromatography-diode array detector. In this work, first, the analytes' extraction was done by a pressurized liquid phase extraction for effective extraction of the analytes from the solid matrix, and then they were concentrated on a DLLME for more concentration of the analytes to reach low limits of detections. The use of DESs was done in both steps to omit the use of toxic organic solvents. Satisfactory results including high extraction recoveries (74-90%), great repeatability (relative standard deviations equal or less than 4.3% and 5.3% for intra- and inter-day precisions), and low limits of detection (0.11-0.29 ng/g) and quantification (0.38-0.98 ng/g) were attained under the optimum conditions. Lastly, the suggested approach was utilized for the determination of the studied pesticides in various egg powder samples marketed in Tabriz, Iran.


Assuntos
Microextração em Fase Líquida , Paration , Resíduos de Praguicidas , Praguicidas , Compostos Organofosforados , Cromatografia Líquida de Alta Pressão , Solventes Eutéticos Profundos , Pós
6.
Perfusion ; : 2676591241252720, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38712960

RESUMO

INTRODUCTION: We aimed to compare the inflammatory cytokines levels of the miniaturized and conventional extracorporeal circuit system. The miniaturized extracorporeal circuit system may be fewer possible inflammation-induced or blood transfusion-related complications. METHODS: We performed a prospective randomized controlled trial (RCT) of 101 patients undergoing congenital heart surgery with CPB (cardiopulmonary bypass, weight ≤15 kg, age ≤2 years). Patients were divided into two different CPB groups randomly by random data form. Blood samples at five different time points and the ultrafiltration fluid before and after CPB were collected in all patients. IL-6, IL-8, and TNF alpha were respectively tested with Abcam ELISA kit. RESULTS: The IL-6 level of blood serum in two groups had no statistical differences between the two groups at all time points. The IL-8 level of blood serum in two groups had no statistical differences right after anesthesia and 5 min after CPB. However, IL-8 level was significantly higher in conventional extracorporeal circuit group than that in miniaturized extracorporeal circuit group at 6 h, 12 h and 24 h after CPB. Blood serum TNF alpha in conventional extracorporeal circuit group was significantly higher at 6 h after CPB than that in miniaturized extracorporeal circuit group. No statistical differences in TNF alpha were found between two groups right after anesthesia and at 5 min after CPB, 12 h and 24 h after CPB. In ultrafiltration fluid, no statistical differences were found in IL-6, IL-8 nor TNF alpha between two groups in all time. No statistical differences were found in ICU (intensive care unit) stay and mechanical ventilation time between the two groups. The blood transfusion rate was significantly lower in miniaturized extracorporeal circuit group. CONCLUSION: Implementing the miniaturized extracorporeal circuit system could decrease the inflammatory cytokines at a certain level. The blood transfusion rate is significantly lower in miniaturized extracorporeal circuit group This indicates the miniaturized extracorporeal circuit system might be a safer CPB strategy with fewer possible inflammation-induced or blood transfusion-related complications.

7.
Sensors (Basel) ; 24(12)2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38931704

RESUMO

We present the design, fabrication, and testing of a low-cost, miniaturized detection system that utilizes chemiluminescence to measure the presence of adenosine triphosphate (ATP), the energy unit in biological systems, in water samples. The ATP-luciferin chemiluminescent solution was faced to a silicon photomultiplier (SiPM) for highly sensitive real-time detection. This system can detect ATP concentrations as low as 0.2 nM, with a sensitivity of 79.5 A/M. Additionally, it offers rapid response times and can measure the characteristic time required for reactant diffusion and mixing within the reaction volume, determined to be 0.3 ± 0.1 s. This corresponds to a diffusion velocity of approximately 44 ± 14 mm2/s.


Assuntos
Trifosfato de Adenosina , Medições Luminescentes , Água , Trifosfato de Adenosina/análise , Água/química , Medições Luminescentes/métodos , Luminescência , Técnicas Biossensoriais/métodos
8.
Sensors (Basel) ; 24(13)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-39001074

RESUMO

A sensitive, miniaturized, ultrawideband probe is proposed for near-field measurements. The proposed probe is based on a new V-shaped tip design and a slope structure resulting in better field distribution and impedance matching with a span bandwidth from 10 kHz up to 52 GHz, which is compatible with ultrawideband applications. The proposed E-probe fabrication process utilizes a four-layer printed circuit board (PCB) using Rogers RO4003 (tm) and RO4450 high-performance dielectrics, with εr = 3.55 and 3.3, respectively. The probe length is 40 mm with a minimum width of 4 mm, which is suitable for narrow, complex, and integrated PCBs. The passive E-probe sensitivity is -106.29 dBm and -87.48 dBm at 2 GHz and 40 GHz, respectively. It has a very small spatial resolution of 0.5 mm at 20, 25, 30, and 35 GHz. The probe is small and cheap and can diagnose electromagnetic interference (EMI) in electronic systems such as telemetry, UAVs, and avionics.

9.
Sensors (Basel) ; 24(5)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38475120

RESUMO

Repetitive transcranial magnetic stimulation (rTMS) is a rapidly developing therapeutic modality for the safe and effective treatment of neuropsychiatric disorders. However, clinical rTMS driving systems and head coils are large, heavy, and expensive, so miniaturized, affordable rTMS devices may facilitate treatment access for patients at home, in underserved areas, in field and mobile hospitals, on ships and submarines, and in space. The central component of a portable rTMS system is a miniaturized, lightweight coil. Such a coil, when mated to lightweight driving circuits, must be able to induce B and E fields of sufficient intensity for medical use. This paper newly identifies and validates salient theoretical considerations specific to the dimensional scaling and miniaturization of coil geometries, particularly figure-8 coils, and delineates novel, key design criteria. In this context, the essential requirement of matching coil inductance with the characteristic resistance of the driver switches is highlighted. Computer simulations predicted E- and B-fields which were validated via benchtop experiments. Using a miniaturized coil with dimensions of 76 mm × 38 mm and weighing only 12.6 g, the peak E-field was 87 V/m at a distance of 1.5 cm. Practical considerations limited the maximum voltage and current to 350 V and 3.1 kA, respectively; nonetheless, this peak E-field value was well within the intensity range, 60-120 V/m, generally held to be therapeutically relevant. The presented parameters and results delineate coil and circuit guidelines for a future miniaturized, power-scalable rTMS system able to generate pulsed E-fields of sufficient amplitude for potential clinical use.


Assuntos
Projetos de Pesquisa , Estimulação Magnética Transcraniana , Humanos , Estimulação Magnética Transcraniana/métodos , Resultado do Tratamento , Simulação por Computador
10.
Sensors (Basel) ; 24(9)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38733006

RESUMO

Electrochemical measurements are vital to a wide range of applications such as air quality monitoring, biological testing, food industry, and more. Integrated circuits have been used to implement miniaturized and low-power electrochemical potentiostats that are suitable for wearable devices. However, employing modern integrated circuit technologies with low supply voltage precludes the utilization of electrochemical reactions that require a higher potential window. In this paper, we present a novel circuit architecture that utilizes dynamic voltage at the working electrode of an electrochemical cell to effectively enhance the supported voltage range compared to traditional designs, increasing the cell voltage range by 46% and 88% for positive and negative cell voltages, respectively. In return, this facilitates a wider range of bias voltages in an electrochemical cell, and, therefore, opens integrated microsystems to a broader class of electrochemical reactions. The circuit was implemented in 180 nm technology and consumes 2.047 mW of power. It supports a bias potential range of 1.1 V to -2.12 V and cell potential range of 2.41 V to -3.11 V that is nearly double the range in conventional designs.

11.
Sensors (Basel) ; 24(4)2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38400373

RESUMO

Broadband filtering and reconstruction-based spectral measurement represent a hot technical route for miniaturized spectral measurement; the measurement encoding scheme has a great effect on the spectral reconstruction fidelity. The existing spectral encoding schemes are usually complex and hard to implement; thus, the applications are severely limited. Considering this, here, a simple spectral encoding method based on a triangular matrix is designed. The condition number of the proposed spectral encoding system is estimated and demonstrated to be relatively low theoretically; then, verification experiments are carried out, and the results show that the proposed encoding can work well under precise or unprecise encoding and measurement conditions; therefore, the proposed scheme is demonstrated to be an effective trade-off of the spectral encoding efficiency and implementation cost.

12.
Sensors (Basel) ; 24(6)2024 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-38544053

RESUMO

The carbon-fiber-reinforced polymer (CFRP) bending structure is widely used in aviation. The emergence and spread of delamination damage will decrease the safety of in-service bending structures. Lamb waves can effectively identify delamination damage as a high-damage-sensitivity detection tool. For this present study, the signal difference coefficient (SDC) was introduced to quantify delamination damage and evaluate the sensitivity of A0-mode and S0-mode Lamb waves to delamination damage. The simulation results show that compared with the S0-mode Lamb wave, the A0-mode Lamb wave exhibits higher delamination damage sensitivity. The delamination damage can be quantified based on the strong correlation between the SDC and the delamination damage size. The control effect of the linear array PZT phase time-delay method on the Lamb wave mode was investigated by simulation. The phase time-delay method realizes the generation of a single-mode Lamb wave, which can separately excite the A0-mode and S0-mode Lamb wave to identify delamination damage of different sizes. The A0-mode Lamb wave was excited by the developed one-dimensional miniaturized linear comb transducer (LCT), which was used to conduct the detection experiment on the CFRP bending plate with delamination damage sizes of Φ6.0 mm, Φ10.0 mm, and Φ15.0 mm. The experimental results verify the correctness of the simulation. According to the Hermite interpolation results of the finite-element simulation data, the relationship between the delamination damage size and the SDC was fitted by the Gaussian function and Rational function, which can accurately quantify the delamination damage. The absolute error of the delamination damage quantification with Gaussian and Rational fitting expression does not exceed 0.8 mm and 0.7 mm, and the percentage error is not more than 8% and 7%. The detection and signal processing methods employed in the present research are easy to operate and implement, and accurate delamination damage quantification results have been obtained.

13.
Int J Mol Sci ; 25(5)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38473836

RESUMO

Immunoadsorption (IA) has proven to be clinically effective in the treatment of steroid-refractory multiple sclerosis (MS) relapses, but its mechanism of action remains unclear. We used miniaturized adsorber devices with a tryptophan-immobilized polyvinyl alcohol (PVA) gel sorbent to mimic the IA treatment of patients with MS in vitro. The plasma was screened before and after adsorption with regard to disease-specific mediators, and the effect of the IA treatment on the migration of neutrophils and the integrity of the endothelial cell barrier was tested in cell-based models. The in vitro IA treatment with miniaturized adsorbers resulted in reduced plasma levels of cytokines and chemokines. We also found a reduced migration of neutrophils towards patient plasma treated with the adsorbers. Furthermore, the IA-treated plasma had a positive effect on the endothelial cell barrier's integrity in the cell culture model. Our findings suggest that IA results in a reduced infiltration of cells into the central nervous system by reducing leukocyte transmigration and preventing blood-brain barrier breakdown. This novel approach of performing in vitro blood purification therapies on actual patient samples with miniaturized adsorbers and testing their effects in cell-based assays that investigate specific hypotheses of the pathophysiology provides a promising platform for elucidating the mechanisms of action of those therapies in various diseases.


Assuntos
Esclerose Múltipla , Humanos , Projetos Piloto , Plasma , Neutrófilos , Leucócitos
14.
J Anat ; 242(6): 1012-1028, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36774410

RESUMO

Lanceolate nerve endings (LNEs) surrounding hair follicles (HFs) play an important role in detecting hair deflection. Complexes of the LNEs form a palisade-like structure along the longitudinal axis of hair roots in which axons are sandwiched between two processes of terminal Schwann cells (tSCs) at the isthmus of HFs. The structure and molecular mechanism of LNEs in animal sinus hair, pelage, and human vellus hairs have been investigated. Despite the high density of HFs in human scalp skin, the LNEs in human terminal HFs have not been investigated. In this study, we aimed to reveal the distribution and ultrastructure of LNEs in terminal HFs of human scalp skin. Using light-sheet microscopy and immunostaining, the LNEs were observed at one terminal HF but not at the other terminal HFs in the same follicular unit. The ultrastructure of the LNEs of terminal HFs in human scalp skin was characterized using correlated light and electron microscopy (CLEM). Confocal laser microscopy and transmission electron microscopy of serial transverse sections of HFs revealed that LNEs were aligned adjacent to the basal lamina outside the outer root sheath (ORS), at the isthmus of terminal HFs, and adjacent to CD200-positive ORS cells in the upper bulge region. Moreover, axons with abundant mitochondria were sandwiched between tSCs. Three-dimensional CLEM, specifically confocal laser microscopy and focused ion beam scanning electron microscopy, of stained serial transverse sections revealed that LNEs were wrapped with type I and type II tSCs, with the processes protruding from the space between the Schwann cells. Moreover, the ultrastructures of LNEs at miniaturized HFs were similar to those of LNEs at terminal HFs. Preembedding immunoelectron microscopy revealed that Piezo-type mechanosensitive ion channel component 2 (Piezo2), a gated ion channel, was in axons and tSCs and adjacent to the cell membrane of axons and tSCs, suggesting that LNEs function as mechanosensors. The number of LNEs increased as the diameter of the ORS decreased, suggesting that LNEs dynamically adapt to the HF environment as terminal HFs miniaturize into vellus-like hair. These findings will provide insights for investigations of mechanosensory organs, aging, and re-innervation during wound healing.


Assuntos
Folículo Piloso , Couro Cabeludo , Animais , Humanos , Folículo Piloso/inervação , Folículo Piloso/ultraestrutura , Microscopia Eletrônica de Volume , Cabelo , Terminações Nervosas/ultraestrutura , Microscopia Eletrônica de Varredura
15.
Biotechnol Bioeng ; 120(9): 2523-2541, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37079436

RESUMO

A novel approach of design of experiment (DoE) is developed for the optimization of key substrates of the culture medium, amino acids, and sugars, by utilizing perfusion microbioreactors with 2 mL working volume, operated in high cell density continuous mode, to explore the design space. A mixture DoE based on a simplex-centroid is proposed to test multiple medium blends in parallel perfusion runs, where the amino acids concentrations are selected based on the culture behavior in presence of different amino acid mixtures, and using targeted specific consumption rates. An optimized medium is identified with models predicting the culture parameters and product quality attributes (G0 and G1 level N-glycans) as a function of the medium composition. It is then validated in runs performed in perfusion microbioreactor in comparison with stirred-tank bioreactors equipped with alternating tangential flow filtration (ATF) or with tangential flow filtration (TFF) for cell separation, showing overall a similar process performance and N-glycosylation profile of the produced antibody. These results demonstrate that the present development strategy generates a perfusion medium with optimized performance for stable Chinese hamster ovary (CHO) cell cultures operated with very high cell densities of 60 × 106 and 120 × 106 cells/mL and a low cell-specific perfusion rate of 17 pL/cell/day, which is among the lowest reported and is in line with the framework recently published by the industry.


Assuntos
Anticorpos Monoclonais , Reatores Biológicos , Cricetinae , Animais , Cricetulus , Células CHO , Perfusão/métodos , Anticorpos Monoclonais/metabolismo , Técnicas de Cultura de Células/métodos
16.
World J Urol ; 41(7): 1943-1949, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37277509

RESUMO

PURPOSE: Stone retrieval can be a laborious aspect of percutaneous nephrolithotomy (PCNL). A unique phenomenon of mini-PCNL is the vortex-effect (VE), a hydrodynamic form of stone retrieval. Additionally, the vacuum-assisted sheath (VAS) was recently developed as a new tool for stone extraction. The purpose of our study is to investigate the impact of renal access angle (as a surrogate for patient positioning) on stone retrieval efficiency and compare the efficiency among methods of stone retrieval. METHODS: A kidney model was filled with 3 mm artificial stones. Access to the mid-calyx was obtained using a 15Fr sheath. Stones were retrieved over three minutes at angles of 0°, 25°, and 75° utilizing the VE, VAS, and basket. Stones were weighed for comparison of stones/retraction and stones/minute. Trials were repeated three times at each angle. RESULTS: Renal access angle of 0° was associated with increased stone retrieval for both the VE and VAS (p < 0.05). The VE was the most effective method for stones retrieved per individual retraction at an angle of 0° (p < 0.005), although when analyzed as stones retrieved per minute, the VE and VAS were no longer statistically different (p = 0.08). At 75°, none of the methods were statistically different, regardless if analyzed as stones per retraction or per minute (p = 0.20-0.40). CONCLUSIONS: Renal access angle of 0° is more efficient for stone retrieval than a steep upward angle. There is no difference in stone retrieval efficiency between the VE and VAS methods, although both are superior to the basket at lower sheath angles.


Assuntos
Cálculos Renais , Nefrolitotomia Percutânea , Nefrostomia Percutânea , Humanos , Nefrolitotomia Percutânea/métodos , Cálculos Renais/cirurgia , Cálculos Renais/complicações , Rim , Cálices Renais , Tecnologia , Resultado do Tratamento , Nefrostomia Percutânea/métodos
17.
Pharm Res ; 40(5): 1283-1298, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37012535

RESUMO

OBJECTIVES: Solid biopharmaceutical products can circumvent lower temperature storage and transport and increase remote access with lower carbon emissions and energy consumption. Saccharides are known stabilizers in a solid protein produced via lyophilization and spray drying (SD). Thus, it is essential to understand the interactions between saccharides and proteins and the stabilization mechanism. METHODS: A miniaturized single droplet drying (MD) method was developed to understand how different saccharides stabilize proteins during drying. We applied our MD to different aqueous saccharide-protein systems and transferred our findings to SD. RESULTS: The poly- and oligosaccharides tend to destabilize the protein during drying. The oligosaccharide, Hydroxypropyl ß-cyclodextrin (HPßCD) shows high aggregation at a high saccharide-to-protein molar ratio (S/P ratio) during MD, and the finding is supported by nanoDSF results. The polysaccharide, Dextran (DEX) leads to larger particles, whereas HPBCD leads to smaller particles. Furthermore, DEX is not able to stabilize the protein at higher S/P ratios either. In contrast, the disaccharide Trehalose Dihydrate (TD) does not increase or induce protein aggregation during the drying of the formulation. It can preserve the protein's secondary structure during drying, already at low concentrations. CONCLUSION: During the drying of S/P formulations containing the saccharides TD and DEX, the MD approach could anticipate the in-process (in) stability of protein X at laboratory-scale SD. In contrast, for the systems with HPßCD, the results obtained by SD were contradictory to MD. This underlines that depending on the drying operation, careful consideration needs to be applied to the selection of saccharides and their ratios.


Assuntos
Dessecação , Secagem por Atomização , 2-Hidroxipropil-beta-Ciclodextrina , Liofilização , Proteínas , Oligossacarídeos , Estabilidade de Medicamentos , Trealose/química
18.
Bioorg Chem ; 136: 106556, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37105002

RESUMO

The approved small-molecule inhibitors of anaplastic lymphoma kinase (ALK) have shown remarkable efficacy in some subset of cancer patients. However, the numerous ALK mutants or fusion partners are resistant to such drugs, greatly limiting their application in clinic. Despite the drug design strategy of proteolysis-targeting chimera (PROTAC) holds great potential to overcome drug resistance in theory, there are obvious disadvantages for the reported PROTACs that include high molecular weight, long linkers, difficult synthesis routes as well as insufficient evidence in activity for diverse ALK mutants. In this study, we designed and synthesized a miniaturized PROTAC of ALK named AP-1 following the principle of minimalist design. Two simple chemical units of ligands and a minimized linker with only two atoms were selected for synthesis of AP-1. At cellular level, AP-1 successfully degraded three types of ALK mutants including NPM-ALK, EML4-ALK and F1174L mutation ALK form with potent activity, high selectivity in ALK-positive cells. In xenograft mouse model, AP-1 showed the stronger antitumor efficacy than ceritinib as well as ALK degraders reported in literatures. AP-1 with an extremely simple PROTAC structure can be served as an effective candidate drug for therapy of various types of ALK-positive cancers. And the design principle of AP-1 has a good guiding significance for overcoming the disadvantages such as excessive molecular weight and poor solubility of PROTAC.


Assuntos
Antineoplásicos , Neoplasias , Quimera de Direcionamento de Proteólise , Animais , Humanos , Camundongos , Antineoplásicos/química , Linhagem Celular Tumoral , Desenho de Fármacos , Resistencia a Medicamentos Antineoplásicos , Mutação , Neoplasias/tratamento farmacológico , Inibidores de Proteínas Quinases/química , Fator de Transcrição AP-1 , Quimera de Direcionamento de Proteólise/química , Quimera de Direcionamento de Proteólise/farmacologia
19.
J Sep Sci ; 46(18): e2300373, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37582640

RESUMO

Nano-liquid chromatography (nanoLC) is gaining significant attention as a primary analytical technique across various scientific domains. Unlike conventional high-performance LC, nanoLC utilizes columns with inner diameters (i.ds.) usually ranging from 10 to 150 µm and operates at mobile phase flow rates between 10 and 1000 nl/min, offering improved chromatographic performance and detectability. Currently, most exploration of nanoLC has focused on particle-packed columns. Although open tubular LC (OTLC) can provide superior performance, optimized OTLC columns require very narrow i.ds. (< 10 µm) and demand challenging instrumentation. At the moment, these challenges have limited the success of OTLC. Nevertheless, remarkable progress has been made in developing and utilizing OTLC systems featuring narrow columns (< 2 µm). Additionally, significant efforts have been made to explore larger columns (10-75 µm i.d), demonstrating practical applicability in many situations. Due to their perceived advantages, interest in OTLC has resurged in the last two decades. This review provides an updated outlook on the latest developments in OTLC, focusing on instrumental challenges, achievements, and advancements in column technology. Moreover, it outlines selected applications that illustrate the potential of OTLC for performing targeted and untargeted studies.

20.
Electrochim Acta ; 451: 142271, 2023 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-36974119

RESUMO

Fast, sensitive, simple, and cheap sensors are highly desirable to be applied in the health system because they improve point-of-care diagnostics, which can reduce the number of cases of infection or even deaths. In this context, here we report the development of a label-free genosensor using a screen-printed electrode modified with 2D-carbonylated graphitic carbon nitride (c-g-C3N4), poly(diallyldimethylammonium) chloride (PDDA), and glutathione-protected gold nanoparticles (GSH-AuNPs) for photoelectrochemical (PEC) detection of SARS-CoV-2. We also made use of Arduino and 3D printing to miniaturize the sensor device. The electrode surface was characterized by AFM and SEM techniques, and the gold nanoparticles by UV-Vis spectrophotometry. For SARS-CoV-2 detection, capture probe DNA was immobilized on the electrode surface. The hybridization of the final genosensor was tested with a synthetic single-strand DNA target and with natural saliva samples using the photoelectrochemistry method. The device presented a linear range from 1 to 10,000 fmol L-1 and a limit of detection of 2.2 and 3.4 fmol L-1 using cpDNA 1A and 3A respectively. The sensibility and accuracy found for the genosensor using cpDNA 1A using biological samples were 93.3 and 80% respectively, indicating the potential of the label-free and portable genosensor to detect SARS-CoV-2 RNA in saliva samples.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA