1.
Magn Reson Med ; 92(1): 15-27, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38501903

RESUMO

Proton resonance frequency shift (PRFS) MR thermometry is the most common method used in clinical thermal treatments because of its fast acquisition and high sensitivity to temperature. However, motion is the biggest obstacle in PRFS MR thermometry for monitoring thermal treatment in moving organs. This challenge arises because of the introduction of phase errors into the PRFS calculation through multiple methods, such as image misregistration, susceptibility changes in the magnetic field, and intraframe motion during MRI acquisition. Various approaches for motion correction have been developed for real-time, motion-robust, and volumetric MR thermometry. However, current technologies have inherent trade-offs among volume coverage, processing time, and temperature accuracy. These tradeoffs should be considered and chosen according to the thermal treatment application. In hyperthermia treatment, precise temperature measurements are of increased importance rather than the requirement for exceedingly high temporal resolution. In contrast, ablation procedures require robust temporal resolution to accurately capture a rapid temperature rise. This paper presents a comprehensive review of current cutting-edge MRI techniques for motion-robust MR thermometry, and recommends which techniques are better suited for each thermal treatment. We expect that this study will help discern the selection of motion-robust MR thermometry strategies and inspire the development of motion-robust volumetric MR thermometry for practical use in clinics.


Assuntos
Imageamento por Ressonância Magnética , Movimento (Física) , Humanos , Imageamento por Ressonância Magnética/métodos , Termometria/métodos , Termografia/métodos , Algoritmos , Hipertermia Induzida , Artefatos
2.
MAGMA ; 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38916681

RESUMO

PURPOSE: To develop a new MR coronary angiography (MRCA) technique by employing a zigzag fan-shaped centric ky-kz k-space trajectory combined with high-resolution deep learning reconstruction (HR-DLR). METHODS: All imaging data were acquired from 12 healthy subjects and 2 patients using two clinical 3-T MR imagers, with institutional review board approval. Ten healthy subjects underwent both standard 3D fast gradient echo (sFGE) and centric ky-kz k-space trajectory FGE (cFGE) acquisitions to compare the scan time and image quality. Quantitative measures were also performed for signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) as well as sharpness of the vessel. Furthermore, the feasibility of the proposed cFGE sequence was assessed in two patients. For assessing the feasibility of the centric ky-kz trajectory, the navigator-echo window of a 30-mm threshold was applied in cFGE, whereas sFGE was applied using a standard 5-mm threshold. Image quality of MRCA using cFGE with HR-DLR and sFGE without HR-DLR was scored in a 5-point scale (non-diagnostic = 1, fair = 2, moderate = 3, good = 4, and excellent = 5). Image evaluation of cFGE, applying HR-DLR, was compared with sFGE without HR-DLR. Friedman test, Wilcoxon signed-rank test, or paired t tests were performed for the comparison of related variables. RESULTS: The actual MRCA scan time of cFGE with a 30-mm threshold was acquired in less than 5 min, achieving nearly 100% efficiency, showcasing its expeditious and robustness. In contrast, sFGE was acquired with a 5-mm threshold and had an average scan time of approximately 15 min. Overall image quality for MRCA was scored 3.3 for sFGE and 2.7 for cFGE without HR-DLR but increased to 3.6 for cFGE with HR-DLR and (p < 0.05). The clinical result of patients obtained within 5 min showed good quality images in both patients, even with a stent, without artifacts. Quantitative measures of SNR, CNR, and sharpness of vessel presented higher in cFGE with HR-DLR. CONCLUSION: Our findings demonstrate a robust, time-efficient solution for high-quality MRCA, enhancing patient comfort and increasing clinical throughput.

3.
Neuroimage ; 283: 120419, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37871759

RESUMO

Quantitative Susceptibility Mapping has the potential to provide additional insights into neurological diseases but is typically based on a quite long (5-10 min) 3D gradient-echo scan which is highly sensitive to motion. We propose an ultra-fast acquisition based on three orthogonal (sagittal, coronal and axial) 2D simultaneous multi-slice EPI scans with 1 mm in-plane resolution and 3 mm thick slices. Images in each orientation are corrected for susceptibility-related distortions and co-registered with an iterative non-linear Minimum Deformation Averaging (Volgenmodel) approach to generate a high SNR, super-resolution data set with an isotropic resolution of close to 1 mm. The net acquisition time is 3 times the volume acquisition time of EPI or about 12 s, but the three volumes could also replace "dummy scans" in fMRI, making it feasible to acquire QSM in little or No Additional Time for Imaging (NATIve). NATIve QSM values agreed well with reference 3D GRE QSM in the basal ganglia in healthy subjects. In patients with multiple sclerosis, there was also a good agreement between the susceptibility values within lesions and control ROIs and all lesions which could be seen on 3D GRE QSMs could also be visualized on NATIve QSMs. The approach is faster than conventional 3D GRE by a factor of 25-50 and faster than 3D EPI by a factor of 3-5. As a 2D technique, NATIve QSM was shown to be much more robust to motion than the 3D GRE and 3D EPI, opening up the possibility of studying neurological diseases involving iron accumulation and demyelination in patients who find it difficult to lie still for long enough to acquire QSM data with conventional methods.


Assuntos
Imagem Ecoplanar , Humanos , Imagem Ecoplanar/métodos , Gânglios da Base/diagnóstico por imagem
4.
Magn Reson Med ; 89(3): 908-921, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36404637

RESUMO

PURPOSE: To evaluate feasibility and reproducibility of liver diffusion-weighted (DW) MRI using cardiac-motion-robust, blood-suppressed, reduced-distortion techniques. METHODS: DW-MRI data were acquired at 3T in an anatomically accurate liver phantom including controlled pulsatile motion, in eight healthy volunteers and four patients with known or suspected liver metastases. Standard monopolar and motion-robust (M1-nulled, and M1-optimized) DW gradient waveforms were each acquired with single-shot echo-planar imaging (ssEPI) and multishot EPI (msEPI). In the motion phantom, apparent diffusion coefficient (ADC) was measured in the motion-affected volume. In healthy volunteers, ADC was measured in the left and right liver lobes separately to evaluate ADC reproducibility between the two lobes. Image distortions were quantified using the normalized cross-correlation coefficient, with an undistorted T2-weighted reference. RESULTS: In the motion phantom, ADC mean and SD in motion-affected volumes substantially increased with increasing motion for monopolar waveforms. ADC remained stable in the presence of increasing motion when using motion-robust waveforms. M1-optimized waveforms suppressed slow flow signal present with M1-nulled waveforms. In healthy volunteers, monopolar waveforms generated significantly different ADC measurements between left and right liver lobes ( p = 0 . 0078 $$ p=0.0078 $$ , reproducibility coefficients (RPC) =  470 × 1 0 - 6 $$ 470\times 1{0}^{-6} $$ mm 2 $$ {}^2 $$ /s for monopolar-msEPI), while M1-optimized waveforms showed more reproducible ADC values ( p = 0 . 29 $$ p=0.29 $$ , RPC = 220 × 1 0 - 6 $$ \mathrm{RPC}=220\times 1{0}^{-6} $$ mm 2 $$ {}^2 $$ /s for M1-optimized-msEPI). In phantom and healthy volunteer studies, motion-robust acquisitions with msEPI showed significantly reduced image distortion ( p < 0 . 001 $$ p<0.001 $$ ) compared to ssEPI. Patient scans showed reduction of wormhole artifacts when combining M1-optimized waveforms with msEPI. CONCLUSION: Synergistic effects of combined M1-optimized diffusion waveforms and msEPI acquisitions enable reproducible liver DWI with motion robustness, blood signal suppression, and reduced distortion.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias Hepáticas , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Movimento (Física) , Neoplasias Hepáticas/diagnóstico por imagem , Imagem Ecoplanar/métodos
5.
Magn Reson Med ; 87(1): 102-119, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34398991

RESUMO

PURPOSE: To address head motion in brain MRI with a novel motion-resolved imaging framework, with application to motion-robust quantitative multiparametric mapping. METHODS: MR multitasking conceptualizes the underlying multiparametric image in the presence of motion as a multidimensional low-rank tensor. By incorporating a motion-state dimension into the parameter dimensions and introducing unsupervised motion-state binning and outlier motion reweighting mechanisms, the brain motion can be readily resolved for motion-robust quantitative imaging. A numerical motion phantom was used to simulate different discrete and periodic motion patterns under various translational and rotational scenarios, as well as investigate the sensitivity to exceptionally small and large displacements. In vivo brain MRI was performed to also evaluate different real discrete and periodic motion patterns. The effectiveness of motion-resolved imaging for simultaneous T1 /T2 /T1ρ mapping in the brain was investigated. RESULTS: For all 14 simulation scenarios of small, intermediate, and large motion displacements, the motion-resolved approach produced T1 /T2 /T1ρ maps with less absolute difference errors against the ground truth, lower RMSE, and higher structural similarity index measure of T1 /T2 /T1ρ measurements compared to motion removal, and no motion handling. For in vivo experiments, the motion-resolved approach produced T1 /T2 /T1ρ maps with the best image quality free from motion artifacts under random discrete motion, tremor, periodic shaking, and nodding patterns compared to motion removal and no motion handling. The proposed method also yielded T1 /T2 /T1ρ measurement distributions closest to the motion-free reference, with minimal measurement bias and variance. CONCLUSION: Motion-resolved quantitative brain imaging is achieved with multitasking, which is generalizable to various head motion patterns without explicit need for registration-based motion correction.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Artefatos , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Movimento (Física) , Imagens de Fantasmas
6.
Magn Reson Med ; 85(5): 2417-2433, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33314281

RESUMO

PURPOSE: To implement the time-resolved relaxometry PEPTIDE technique into a diffusion acquisition to provide self-navigated, distortion- and blurring-free diffusion imaging that is robust to motion, while simultaneously providing T2 and T2∗ mapping. THEORY AND METHODS: The PEPTIDE readout was implemented into a spin-echo diffusion acquisition, enabling reconstruction of a time-series of T2 - and T2∗ -weighted images, free from conventional echo planar imaging (EPI) distortion and blurring, for each diffusion-encoding. Robustness of PEPTIDE to motion and shot-to-shot phase variation was examined through a deliberate motion-corrupted diffusion experiment. Two diffusion-relaxometry in vivo brain protocols were also examined: (1)1 × 1 × 3 mm3 across 32 diffusion directions in 20 min, (2)1.5 × 1.5 × 3.0 mm3 across 6 diffusion-weighted images in 3.4 min. T2 , T2∗ , and diffusion parameter maps were calculated from these data. As initial exploration of the rich diffusion-relaxometry data content for use in multi-compartment modeling, PEPTIDE data were acquired of a gadolinium-doped asparagus phantom. These datasets contained two compartments with different relaxation parameters and different diffusion orientation properties, and T2 relaxation variations across these diffusion directions were explored. RESULTS: Diffusion-PEPTIDE showed the capability to provide high quality diffusion images and T2 and T2∗ maps from both protocols. The reconstructions were distortion-free, avoided potential resolution losses exceeding 100% in equivalent EPI acquisitions, and showed tolerance to nearly 30° of rotational motion. Expected variation in T2 values as a function of diffusion direction was observed in the two-compartment asparagus phantom (P < .01), demonstrating potential to explore diffusion-PEPTIDE data for multi-compartment modeling. CONCLUSIONS: Diffusion-PEPTIDE provides highly robust diffusion and relaxometry data and offers potential for future applications in diffusion-relaxometry multi-compartment modeling.


Assuntos
Imagem de Difusão por Ressonância Magnética , Processamento de Imagem Assistida por Computador , Encéfalo/diagnóstico por imagem , Imagem Ecoplanar , Movimento (Física) , Peptídeos
7.
J Magn Reson Imaging ; 51(2): 580-592, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31276263

RESUMO

BACKGROUND: 3D chemical shift-encoded (CSE)-MRI techniques enable assessment of ferumoxytol concentration but are unreliable in the presence of motion. PURPOSE: To evaluate a motion-robust 2D-sequential CSE-MRI for R2* and B0 mapping in ferumoxytol-enhanced MRI of the placenta. STUDY TYPE: Prospective. ANIMAL MODEL: Pregnant rhesus macaques. FIELD STRENGTH/SEQUENCE: 3.0T/CSE-MRI. ASSESSMENT: 2D-sequential CSE-MRI was compared with 3D respiratory-gated CSE-MRI in placental imaging of 11 anesthetized animals at multiple timepoints before and after ferumoxytol administration, and in ferumoxytol phantoms (0 µg/mL-440 µg/mL). Motion artifacts of CSE-MRI in 10 pregnant women without ferumoxytol administration were assessed retrospectively by three blinded readers (4-point Likert scale). The repeatability of CSE-MRI in seven pregnant women was also prospectively studied. STATISTICAL TESTS: Placental R2* and boundary B0 field measurements (ΔB0) were compared between 2D-sequential and 3D respiratory-gated CSE-MRI using linear regression and Bland-Altman analysis. RESULTS: In phantoms, a slope of 0.94 (r2 = 0.99, concordance correlation coefficient ρ = 0.99), and bias of -4.8 s-1 (limit of agreement [LOA], -41.4 s-1 , +31.8 s-1 ) in R2*, and a slope of 1.07 (r2 = 1.00, ρ = 0.99) and bias of 11.4 Hz (LOA -12.0 Hz, +34.8 Hz) in ΔB0 were obtained in 2D CSE-MRI compared with 3D CSE-MRI for reference R2* ≤390 s-1 . In animals, a slope of 0.92 (r2 = 0.97, ρ = 0.98) and bias of -2.2 s-1 (LOA -55.6 s-1 , +51.3 s-1 ) in R2*, and a slope of 1.05 (r2 = 0.95, ρ = 0.97) and bias of 0.4 Hz (LOA -9.0 Hz, +9.7 Hz) in ΔB0 were obtained. In humans, motion-impaired R2* maps in 3D CSE-MRI (Reader 1: 1.8 ± 0.6, Reader 2: 1.3 ± 0.7, Reader 3: 1.9 ± 0.6), while 2D CSE-MRI was motion-free (Reader 1: 2.9 ± 0.3, Reader 2: 3.0 ± 0, Reader 3: 3.0 ± 0). A mean difference of 0.66 s-1 and coefficient of repeatability of 9.48 s-1 for placental R2* were observed in the repeated 2D CSE-MRI. DATA CONCLUSION: 2D-sequential CSE-MRI provides accurate R2* and B0 measurements in ferumoxytol-enhanced placental MRI of animals in the presence of respiratory motion, and motion-robustness in human placental imaging. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2020;51:580-592.


Assuntos
Óxido Ferroso-Férrico , Imageamento por Ressonância Magnética , Animais , Feminino , Humanos , Macaca mulatta , Placenta/diagnóstico por imagem , Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos
8.
AJR Am J Roentgenol ; 215(1): 94-104, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32348181

RESUMO

OBJECTIVE. The purpose of this study was to develop a motion insensitive clinical dynamic contrast-enhanced MRI (DCE-MRI) protocol to assess the response of pleural tumors in clinical trials. MATERIALS AND METHODS. Thirty-two patients with pleura-based lesions were administered contrast material and imaged with gradient-recalled echo DCE-MRI sequence variants: either a traditional cartesian k-space acquisition (FLASH), a time-resolved imaging with stochastic trajectories acquisition (TWIST), or a radial stack-of-stars acquisition (radial) sequence in addition to other standard-of-care imaging sequences. Each image acquisition's sensitivity to motion was evaluated by comparing the motion of the thoracic border in 3D throughout the acquisition. One-way ANOVA was used to compare the image quality between different acquisitions. The 95% CIs were calculated for mean thoracic border displacement. The effects of motion on kinetic parameter estimation were explored with simulations according to clinically acquired data. RESULTS. Radial was the most motion-robust sequence with subvoxel mean displacement in the superior-inferior direction (0.4 ± 1.2 [SD] mm). FLASH showed intermediate displacement (4.6 ± 2.0 mm), whereas TWIST was most sensitive to motion (6.4 ± 3.4 mm). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the images acquired with the radial sequence were on par or better than the FLASH and TWIST sequences when reconstructed with an improved density compensation algorithm. Simulations showed that motion on scans showing pleural-based lesions can lead to markedly inaccurate kinetic parameter estimation and inappropriate kinetic model convergence within a nested model analysis. CONCLUSION. A practical radial k-space trajectory sequence that provides motion-insensitive pharmacokinetic parameters was incorporated as part of the DCE-MRI protocol of pleural tumors. Validation and usefulness in clinical trials assessing response to therapy is needed.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias Pleurais/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Respiração , Sensibilidade e Especificidade , Razão Sinal-Ruído
9.
Magn Reson Med ; 81(5): 3314-3329, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30443929

RESUMO

PURPOSE: To achieve motion-robust diffusion compartment imaging (DCI) in near continuously moving subjects based on simultaneous multi-slice, diffusion-weighted brain MRI. METHODS: Simultaneous multi-slice (SMS) acquisition enables fast and dense sampling of k- and q-space. We propose to achieve motion-robust DCI via slice-level motion correction by exploiting the rigid coupling between simultaneously acquired slices. This coupling provides 3D coverage of the anatomy that substantially constraints the slice-to-volume alignment problem. This is incorporated into an explicit model of motion dynamics that handles continuous and large subject motion in robust DCI reconstruction. RESULTS: We applied the proposed technique, called Motion Tracking based on Simultanous Multislice Registration (MT-SMR) to multi b-value SMS diffusion-weighted brain MRI of healthy volunteers and motion-corrupted scans of 20 pediatric subjects. Quantitative and qualitative evaluation based on fractional anisotropy in unidirectional fiber regions, and DCI in crossing-fiber regions show robust reconstruction in the presence of motion. CONCLUSION: The proposed approach has the potential to extend routine use of SMS DCI in very challenging populations, such as young children, newborns, and non-cooperative patients.


Assuntos
Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Adolescente , Adulto , Algoritmos , Anisotropia , Criança , Pré-Escolar , Voluntários Saudáveis , Humanos , Modelos Estatísticos , Movimento (Física) , Reprodutibilidade dos Testes
10.
Healthc Technol Lett ; 2(1): 6-11, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26609397

RESUMO

The challenge of heart rate monitoring based on wrist photoplethysmography (PPG) during heavy exercise is addressed. PPG is susceptible to motion artefacts, which have to be mitigated for accurate heart rate estimation. Motion artefacts are particularly apparent for wrist devices, for example, a smart watch, because of the high mobility of the arms. Proposed is a low complexity highly accurate heart rate estimation method for continuous heart rate monitoring using wrist PPG. The proposed method achieved 2.57% mean absolute error in a test data set where subjects ran for a maximum speed of 17 km/h.