Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Eur Spine J ; 32(10): 3634-3650, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37555956

RESUMO

BACKGROUND: The incidence of mechanical complications is high in patients undergoing posterior spinal fusion (PSF) for adult spinal deformity (ASD), especially for cases with severe sagittal malalignment or a prior spinal fusion requiring three-column osteotomy (3-CO) or spinopelvic fixation (SPF). The purpose of this systematic review and meta-analysis was to compare the complications, revisions, radiographic spinopelvic parameters, health-related quality of life (HRQoL), and surgical data of PSF using multiple-rod constructs to those of two-rod constructs for the treatment of ASD. METHODS: A comprehensive literature search was performed for relevant studies in PubMed, EMBASE, Web of Science, and the Cochrane Library. Complications, revisions, spinopelvic parameters, HRQoL, and surgical date were compared between patients with ASD who underwent PSF using multiple-rod constructs (multi-rod group) and two-rod constructs (two-rod group). RESULTS: Ten studies, comprising 797 patients with ASD (399 in the multi-rod group and 398 in the two-rod group), were included. All these studies were retrospective cohort studies. There were no significant differences in the surgical, wound-related, and systemic complications between the groups. In the multi-rod group, we noted a significantly lower incidence of rod fracture (RR, 0.43; 95% CI 0.33 to 0.57, P < 0.01), pseudoarthrosis (RR, 0.38; 95% CI 0.28 to 0.53, P < 0.01), and revisions (RR, 0.44; 95% CI 0.33 to 0.58, P < 0.01); a superior restoration of PI-LL (WMD, 3.96; 95% CI 1.03 to 6.88, P < 0.01) and SVA (WMD, 31.53; 95% CI 21.16 to 41.90, P < 0.01); a better improvement of ODI score (WMD, 6.82; 95% CI 2.33 to 11.31, P < 0.01), SRS-22 total score (WMD, 0.44; 95% CI 0.06 to 0.83, P = 0.02), and VAS-BP score (WMD, 1.02; 95% CI 0.31 to 1.73, P < 0.01). CONCLUSION: Compared with the two-rod constructs, PSF using multiple-rod constructs was associated with a lower incidence of mechanical complications, a lower revision rate, a superior restoration of sagittal alignment, and a better improvement of HRQoL, without increasing surgical invasiveness. Multiple-rod constructs should be routinely considered to for ASD patients, especially for cases with severe sagittal malalignment or a prior spinal fusion requiring 3-CO or SPF.


Assuntos
Fusão Vertebral , Procedimentos Cirúrgicos Torácicos , Humanos , Adulto , Estudos Retrospectivos , Fusão Vertebral/efeitos adversos , Qualidade de Vida , Coluna Vertebral
2.
Eur Spine J ; 29(4): 886-895, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31993784

RESUMO

PURPOSE: Multiple-rod constructs (Multi-Rod: extra rods for additional pillar support) are occasionally used in adult spinal deformity (ASD) surgery. We aimed to compare and analyze the general outcome of multi-rod constructs with a matched two-rod cohort, to better understand the differences and the similitudes. METHODS: This is a retrospective matched cohort study including patients with ASD that underwent surgical correction with long posterior instrumentation (more than five levels), pelvic fixation and a minimum 1-year follow-up. Matching was considered with demographical data, preoperative radiographical parameters, preoperative clinical status [health-related quality-of-life (HRQoL) scores] and surgical characteristics (anterior fusion, decompression, rod material, osteotomies). Postoperative radiographical and clinical parameters, as well as complications, were obtained. Univariate and multivariate analysis was performed regarding postoperative improvement, group variables comparison and parameters correlation. RESULTS: Thirty-three patients with multi-rod construct and 33 matched with a two-rod construct were selected from a database with 346 ASD-operated patients. Both groups had a significant improvement with surgical management in the radiographical and HRQoL parameters (p < 0.001). Differences between groups for the postoperative radiographical, clinical and perioperative parameters were not significant. Rod breakage was more frequent in the two-rod group (8 vs 4, p = 0.089), as well as the respective revision surgery for those cases (6 vs 1 p = 0.046). Risk factors related to revision surgery were greater kyphosis correction (p = 0.001), longer instrumentation (p = 0.037) and greater sagittal vertical axis correction (p = 0.049). CONCLUSION: No major disadvantage on the use of multi-rod construct was identified. This supports the benefit of using multi-rod constructs to avoid implant failure. These slides can be retrieved under Electronic Supplementary Material.


Assuntos
Cifose , Escoliose , Fusão Vertebral , Idoso , Estudos de Coortes , Feminino , Humanos , Cifose/cirurgia , Masculino , Reoperação , Estudos Retrospectivos , Escoliose/cirurgia , Resultado do Tratamento
3.
World Neurosurg ; 183: e530-e539, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38159604

RESUMO

OBJECTIVE: In this retrospective study we compared clinicoradiologic outcomes and complication profiles of the traditional 2-rod construct versus the 4-rod construct in patients with adult spinal deformity (ASD) who underwent pedicle subtraction osteotomy (PSO). METHODS: We performed a retrospective review of 208 ASD patients at 2 referral centers who underwent lumbar PSO and long fusion from thoracic to the pelvis. Two different techniques, including the 4-rod construct and the traditional 2-rod technique, were used at the PSO level. Clinicoradiologic outcomes and complication profiles of the patients were documented and compared statistically between the groups. RESULTS: The 4-rod construct was associated with statistically lower rates of rod fracture (44.8% vs. 26.4%, P < 0.01), pedicular screw loosening at the PSO level (25.3% vs. 14.0%, P = 0.04), and reoperation (49.4% vs. 33.9%, P = 0.02). Radiologically, the 4-rod construct was associated with higher degree of lumbar lordosis (LL) (-37.4°vs. -26.8°; P < 0.01) and improved pelvic tilt (PT) (-17.2° vs. -9.9°; P < 0.01) and sacral vertical axis (SVA) corrections (-211.5° vs. -192.2°; P = 0.04). Overall, the 4-rod construct was associated with improved quality of life (P = 0.04) and statistically lower Oswestry Disability Index score at 12 months postoperatively (P < 0.01). CONCLUSIONS: Our results showed that the 4-rod construct was associated with statistically lower rates of rod fracture and pedicular screw loosening at the osteotomy level, higher degree of LL correction and improved PT and SVA than the 2-rod technique. The 4-rod construct was also associated with improved quality of life and Oswestry Disability Index and lower complication profiles.


Assuntos
Lordose , Fusão Vertebral , Adulto , Humanos , Lordose/diagnóstico por imagem , Lordose/cirurgia , Lordose/etiologia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Osteotomia/métodos , Qualidade de Vida , Estudos Retrospectivos , Fusão Vertebral/métodos , Resultado do Tratamento
4.
Neurospine ; 18(4): 816-823, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34670073

RESUMO

OBJECTIVE: To compare the radiological and functional outcomes and complications of adult spinal deformity patients who underwent a pedicle subtraction osteotomy (PSO) below L2 but categorized according to their construct where either 2-rod or multiple-rod construct is applied. METHODS: Sixty-seven patients met the inclusion criteria, and were categorized into 3 groups: 2 rods (2R), multiple rods around the PSO (MRP), multiple rods around the PSO and lumbosacral junction (MRL). Demographic data, operative parameters, spinopelvic parameters, functional outcomes, and complications were collected. RESULTS: Health-related quality of life scores showed a better outcome at 6 months and last follow-up visits in the MRP and MRL groups which were noted on different domains of Scoliosis Research Society-22 questionnaire, 36-item Short Form Health Surve, and Oswestry Disability Index scores (p < 0.05). The 3 groups showed similar rates of rod-related complications with no significant difference (p = 0.95). And inside each group, distribution of complications between pseudarthrosis with revision and rod fracture without revision was also similar (p = 0.99). CONCLUSION: The use of multiple rods across the PSO did not show a better outcome when compared to single rods in terms of incidence and types of mechanical complications. However, better postoperative coronal alignment and health-related quality of life scores in the multiple rods group could be seen demonstrating an improved functional outcome.

5.
J Neurosurg Spine ; : 1-8, 2019 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-31783347

RESUMO

OBJECTIVE: This study investigated the incidence and risk factors of rod fracture (RF) after multiple-rod constructs (MRCs) for adult spinal deformity (ASD) surgery. METHODS: A single-center, single-surgeon consecutive series of adult patients who underwent posterior thoracolumbar fusion at 4 or more levels using MRCs after osteotomy with at least 1 year of follow-up were retrospectively reviewed. Patient characteristics, radiological parameters, operative data, and clinical outcomes (on the Scoliosis Research Society-22r questionnaire) were analyzed at baseline and follow-up. RESULTS: Seventy-six patients were enrolled in this study. RF occurred in 9 patients (11.8%), with all cases involving partial rod breakage. Seven patients (9.2%) underwent revision surgery. There were no significant differences in baseline demographic characteristics, radiological parameters, and surgical factors between the RF and non-RF groups. Multivariable analysis revealed that interbody fusion at the L5-S1 and L4-S1 levels could significantly reduce the occurrence of RF after MRCs for ASD (adjusted odds ratios 0.070 and 0.035, respectively). The RF group had significantly worse function score (mean 2.9 ± 0.8 vs 3.5 ± 0.7) and pain score (mean 2.8 ± 1.0 vs 3.5 ± 0.8) compared with the non-RF group at last visit. CONCLUSIONS: RF occurred in 11.8% of patients with MRCs after ASD surgery. Most RFs occurred at the lumbosacral junction or adjacent level (77%). Interbody fusion at the lumbosacral junction (L5-S1 or L4-S1 level) could significantly prevent the occurrence of RF after MRCs for ASD.

6.
Spine J ; 17(7): 962-968, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28242335

RESUMO

BACKGROUND CONTEXT: Little is known about the effect of rod stiffness as a risk factor of proximal junctional kyphosis (PJK) after adult spinal deformity (ASD) surgery. PURPOSE: The aim of this study was to compare radiographic outcomes after the use of cobalt chrome multiple-rod constructs (CoCr MRCs) and titanium alloy two-rod constructs (Ti TRCs) for ASD surgery with a minimum 1-year follow-up. STUDY DESIGN: Retrospective case-control study in two institutes. PATIENT SAMPLE: We included 54 patients who underwent ASD surgery with fusion to the sacrum in two academic institutes between 2002 and 2015. OUTCOME MEASURES: Radiographic outcomes were measured on the standing lateral radiographs before surgery, 1 month postoperatively, and at ultimate follow-up. The outcome measures were composed of pre- and postoperative sagittal vertical axis (SVA), pre- and postoperative lumbar lordosis (LL), pre- and postoperative thoracic kyphosis (TK)+LL+pelvic incidence (PI), pre- and postoperative PI minus LL, level of uppermost instrumented vertebra (UIV), evaluation of fusion after surgery, the presence of PJK, and the occurrence of rod fracture. MATERIALS AND METHODS: We reviewed the medical records of 54 patients who underwent ASD surgery. Of these, 20 patients had CoCr MRC and 34 patients had Ti TRC. Baseline data and radiographic measurements were compared between the two groups. The Mann-Whitney U test, the chi-square test, and the Fisher exact test were used to compare outcomes between the groups. RESULTS: The patients of the groups were similar in terms of age, gender, diagnosis, number of three-column osteotomy, levels fused, bone mineral density, preoperative TK, pre- and postoperative TK+LL+PI, SVA difference, LL change, pre- and postoperative PI minus LL, and location of UIV (upper or lower thoracic level). However, there were significant differences in the occurrence of PJK and rod breakage (PJK: CoCr MRC: 12 [60%] vs. Ti TRC: 9 [26.5%], p=.015; occurrence of rod breakage: CoCr MRC: 0 [0%] vs. Ti TRC: 11 [32.4%], p=.004). The time of PJK was less than 12 months after surgery in the CoCr MRC group. However, 55.5% (5/9) of PJK developed over 12 months after surgery in the Ti TRC group. CONCLUSIONS: Increasing the rod stiffness by the use of cobalt chrome rod and can prevent rod breakage but adversely affects the occurrence and the time of PJK.


Assuntos
Ligas de Cromo/efeitos adversos , Fixadores Internos/efeitos adversos , Cifose/cirurgia , Osteotomia/métodos , Complicações Pós-Operatórias/etiologia , Falha de Prótese/etiologia , Fusão Vertebral/métodos , Idoso , Feminino , Humanos , Fixadores Internos/normas , Masculino , Pessoa de Meia-Idade , Osteotomia/efeitos adversos , Osteotomia/instrumentação , Complicações Pós-Operatórias/epidemiologia , Radiografia , Sacro/diagnóstico por imagem , Sacro/cirurgia , Fusão Vertebral/efeitos adversos , Fusão Vertebral/instrumentação , Titânio/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA