Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 29(Pt 5): 1223-1231, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36073881

RESUMO

The acquisition speed and spatial resolution of X-ray nanotomography have continuously improved over the last decades. Coherent diffraction-based techniques breach the 10 nm resolution barrier frequently and thus pose stringent demands on sample positioning accuracy and stability. At the same time there is an increasing desire to accommodate in situ or operando measurements. Here, an environmental control system for X-ray nanotomography is introduced to regulate the temperature of a sample from room temperature up to 850°C in a controlled atmospheric composition. The system allows for a 360° sample rotation, permitting tomographic studies in situ or operando free of missing wedge constraints. The system is implemented and available at the flOMNI microscope at the Swiss Light Source. In addition to the environmental control system itself, the related modifications of flOMNI are described. Tomographic measurements of a nanoporous gold sample at 50°C and 600°C at a resolution of sub-20 nm demonstrate the performance of the device.

2.
J Synchrotron Radiat ; 29(Pt 3): 843-852, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35511016

RESUMO

X-ray nano-tomography with phase contrast (nanoCT) using synchrotron radiation is a powerful tool to non-destructively investigate 3D material properties at the nanoscale. In large bone lesions, such as severe bone fractures, bone cancer or other diseases, bone grafts substituting the lost bone might be necessary. Such grafts can be of biological origin or be composed of a synthetic bone substitute. The long-term functioning of artificial bone substitutes depends on many factors. Synchrotron nanoCT imaging has great potential to contribute to further the understanding of integration of implants into bone tissue by imaging the spatial interaction between bone tissue and implant, and by accessing the interface between implant material and bone tissue. With this aim, a methodology for evaluating the image quality is presented for in-line phase contrast nanoCT images of bone scaffold samples. A PMMA-embedded tricalcium phosphate scaffold was used with both a closed and an open porosity structure and bone ingrowths as a representative system of three known materials. Parameters such as spatial resolution and signal-to-noise ratio were extracted and used to explore and quantitatively compare the effects of implementation choices in the imaging setup, such as camera technology and imaging energy, on the resulting image quality. Increasing the X-ray energy from 17.5 keV to 29.6 keV leads to a notable improvement in image quality regardless of the camera technology used, with the two tested camera setups performing at a comparable level when the recorded intensity was kept constant.


Assuntos
Materiais Biocompatíveis , Tomografia Computadorizada por Raios X , Osso e Ossos/diagnóstico por imagem , Imageamento Tridimensional/métodos , Microscopia de Contraste de Fase , Síncrotrons
3.
J Synchrotron Radiat ; 29(Pt 5): 1258-1264, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36073885

RESUMO

An X-ray computed nano-tomography (nano-CT) system has been established at the BL33XU beamline of SPring-8. The optical system consists of pseudo-Köhler illumination with a sector condenser zone plate, an apodization Fresnel zone plate as the objective lens, and a Zernike phase plate. The imaging detector is a fiber-coupling type X-ray camera. The performance of the X-ray nano-CT system was confirmed by imaging an X-ray test chart. The system was subsequently applied to the observation of a microporous layer for polymer electrolyte fuel cells and a simulated microporous layer including liquid water. The nano-CT system, which can perform a computed tomography measurement in less than 4 min, allowed visualization of a spherical water droplet produced in the microporous layer. In the present study, the shape of water droplets in a nanoscale porous structure is investigated.

4.
J Synchrotron Radiat ; 28(Pt 6): 1909-1915, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34738945

RESUMO

Nano-resolution full-field transmission X-ray microscopy has been successfully applied to a wide range of research fields thanks to its capability of non-destructively reconstructing the 3D structure with high resolution. Due to constraints in the practical implementations, the nano-tomography data is often associated with a random image jitter, resulting from imperfections in the hardware setup. Without a proper image registration process prior to the reconstruction, the quality of the result will be compromised. Here a deep-learning-based image jitter correction method is presented, which registers the projective images with high efficiency and accuracy, facilitating a high-quality tomographic reconstruction. This development is demonstrated and validated using synthetic and experimental datasets. The method is effective and readily applicable to a broad range of applications. Together with this paper, the source code is published and adoptions and improvements from our colleagues in this field are welcomed.

5.
J Synchrotron Radiat ; 27(Pt 2): 472-476, 2020 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-32153287

RESUMO

A simple two-spindle based lathe system for the preparation of cylindrical samples intended for X-ray tomography is presented. The setup can operate at room temperature as well as under cryogenic conditions, allowing the preparation of samples down to 20 and 50 µm in diameter, respectively, within minutes. Case studies are presented involving the preparation of a brittle biomineral brachiopod shell and cryogenically fixed soft brain tissue, and their examination by means of ptychographic X-ray computed tomography reveals the preparation method to be mainly free from causing artefacts. Since this lathe system easily yields near-cylindrical samples ideal for tomography, a usage for a wide variety of otherwise challenging specimens is anticipated, in addition to potential use as a time- and cost-saving tool prior to focused ion-beam milling. Fast sample preparation becomes especially important in relation to shorter measurement times expected in next-generation synchrotron sources.

6.
J Synchrotron Radiat ; 27(Pt 3): 746-752, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32381777

RESUMO

A versatile, compact heater designed at National Synchrotron Light Source-II for in situ X-ray nano-imaging in a full-field transmission X-ray microscope is presented. Heater design for nano-imaging is challenging, combining tight spatial constraints with stringent design requirements for the temperature range and stability. Finite-element modeling and analytical calculations were used to determine the heater design parameters. Performance tests demonstrated reliable and stable performance, including maintaining the exterior casing close to room temperature while the heater is operating at above 1100°C, a homogenous heating zone and small temperature fluctuations. Two scientific experiments are presented to demonstrate the heater capabilities: (i) in situ 3D nano-tomography including a study of metal dealloying in a liquid molten salt extreme environment, and (ii) a study of pore formation in icosahedral quasicrystals. The progression of structural changes in both studies were clearly resolved in 3D, showing that the new heater enables powerful capabilities to directly visualize and quantify 3D morphological evolution of materials under real conditions by X-ray nano-imaging at elevated temperature during synthesis, fabrication and operation processes. This heater design concept can be applied to other applications where a precise, compact heater design is required.

7.
J Am Ceram Soc ; 101(4): 1453-1470, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29887617

RESUMO

Advances in nano-computed X-ray tomography (nCT), nano X-ray fluorescence spectrometry (nXRF), and high-performance computing have enabled the first direct comparison between observations of three-dimensional nanoscale microstructure evolution during cement hydration and computer simulations of the same microstructure using HydratiCA. nCT observations of a collection of triclinic tricalcium silicate (Ca3SiO5) particles reacting in a calcium hydroxide solution are reported and compared to simulations that duplicate, as nearly as possible, the thermal and chemical conditions of those experiments. Particular points of comparison are the time dependence of the solid phase volume fractions, spatial distributions, and morphologies. Comparisons made at 7 h of reaction indicate that the simulated and observed volumes of Ca3SiO5 consumed by hydration agree to within the measurement uncertainty. The location of simulated hydration product is qualitatively consistent with the observations, but the outer envelope of hydration product observed by nCT encloses more than twice the volume of hydration product in the simulations at the same time. Simultaneous nXRF measurements of the same observation volume imply calcium and silicon concentrations within the observed hydration product envelope that are consistent with Ca(OH)2 embedded in a sparse network of calcium silicate hydrate (C-S-H) that contains about 70 % occluded porosity in addition to the amount usually accounted as gel porosity. An anomalously large volume of Ca(OH)2 near the particles is observed both in the experiments and in the simulations, and can be explained as originating from the hydration of additional particles outside the field of view. Possible origins of the unusually large amount of observed occluded porosity are discussed.

8.
Cem Concr Res ; 88: 157-169, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29880979

RESUMO

Disagreements about the mechanisms of cement hydration remain despite the fact that portland cement has been studied extensively for over 100 years. One reason for this is that direct observation of the change in microstructure and chemistry are challenging for many experimental techniques. This paper presents results from synchrotron nano X-ray tomography and fluorescence imaging. The data show unprecedented direct observations of small collections of C3S particles before and after different periods of hydration in 15 mmol/L lime solution. X-ray absorption contrast is used to make three dimensional maps of the changes of these materials with time. The chemical compositions of hydration products are then identified with X-ray fluorescence mapping and scanning electron microscopy. These experiments are used to provide insight into the rate and morphology of the microstructure formation.

9.
J Synchrotron Radiat ; 22(4): 1091-5, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26134816

RESUMO

For the first time, the three-dimensional (3D) ultrastructure of an intact rice pollen cell has been obtained using a full-field transmission hard X-ray microscope operated in Zernike phase contrast mode. After reconstruction and segmentation from a series of projection images, complete 3D structural information of a 35 µm rice pollen grain is presented at a resolution of ∼100 nm. The reconstruction allows a clear differentiation of various subcellular structures within the rice pollen grain, including aperture, lipid body, mitochondrion, nucleus and vacuole. Furthermore, quantitative information was obtained about the distribution of cytoplasmic organelles and the volume percentage of each kind of organelle. These results demonstrate that transmission X-ray microscopy can be quite powerful for non-destructive investigation of 3D structures of whole eukaryotic cells.


Assuntos
Imageamento Tridimensional , Microscopia/métodos , Oryza/ultraestrutura , Pólen/ultraestrutura , Organelas/ultraestrutura
10.
J Synchrotron Radiat ; 21(Pt 5): 1175-9, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25178009

RESUMO

Poly(lactic co-glycolic acid) (PLGA) is widely used in diverse fields, especially in delivering biologically active proteins and drugs. For these applications, the knowledge of morphology and microstructure of PLGA micro-porous microspheres is of great importance since they strongly influence the drug delivering efficiency. In this study, micro-porous PLGA microspheres loaded by bovine serum albumin are investigated by using a full-field Zernike phase contrast transmission hard X-ray microscope. From three-dimensional reconstructions and segmentations, fundamental microstructural parameters such as size, shape, distribution and volume ratio among pores and proteins inside PLGA microspheres were obtained. These parameters are useful to understand the relationship between the internal microstructure and drug encapsulation, as well as the drug release efficiency of PLGA microspheres. The presented results demonstrate the capability of hard X-ray nano-tomography to characterize porous microspheres loaded with proteins and drugs, and also open a way to analyse, optimize and design new PLGA microspheres for specific applications.


Assuntos
Ácido Láctico/química , Microesferas , Polímeros/química , Tomografia por Raios X/métodos , Sistemas de Liberação de Medicamentos , Imageamento Tridimensional , Tamanho da Partícula , Poliésteres , Porosidade , Albumina Sérica
11.
Adv Sci (Weinh) ; 11(2): e2301873, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38009788

RESUMO

Small voids in the absorber layer of thin-film solar cells are generally suspected to impair photovoltaic performance. They have been studied on Cu(In,Ga)Se2 cells with conventional laboratory techniques, albeit limited to surface characterization and often affected by sample-preparation artifacts. Here, synchrotron imaging is performed on a fully operational as-deposited solar cell containing a few tens of voids. By measuring operando current and X-ray excited optical luminescence, the local electrical and optical performance in the proximity of the voids are estimated, and via ptychographic tomography, the depth in the absorber of the voids is quantified. Besides, the complex network of material-deficit structures between the absorber and the top electrode is highlighted. Despite certain local impairments, the massive presence of voids in the absorber suggests they only have a limited detrimental impact on performance.

12.
Small Methods ; 8(1): e2300452, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37817378

RESUMO

Li-O2 batteries (LOB) performance degradation ultimately occurs through the accumulation of discharge products and irreversible clogging of the porous electrode during the cycling. Electrode binder degradation in the presence of reduced oxygen species can result in additional coating of the conductive surface, exacerbating capacity fading. Herein, a facile method to fabricate free-standing is established, binder-free electrodes for LOBs in which multi-wall carbon nanotubes form cross-linked networks exhibiting high porosity, conductivity, and flexibility. These electrodes demonstrate high reproducibility upon cycling in LOBs. After cell death, efficient and inexpensive methods to wash away the accumulated discharge products are demonstrated, as reconditioning method. The second life usage of these electrodes is validated, without noticeable loss of performance. These findings aim to assist in the development of greener high energy density batteries while reducing manufacturing and recycling costs.

13.
ACS Appl Mater Interfaces ; 15(51): 59319-59328, 2023 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-38085792

RESUMO

Li-ion battery cathode active materials obtained from different sources or preparation methods often exhibit broadly divergent performance and stability despite no obvious differences in morphology, purity, and crystallinity. We show how state-of-the-art, commercial, nominally single crystalline LiNi0.6Mn0.2Co0.2O2 (NMC-622) particles possess extensive internal nanostructure even in the pristine state. Scanning X-ray diffraction microscopy reveals the presence of interlayer strain gradients, and crystal bending is attributed to oxygen vacancies. Phase contrast X-ray nano-tomography reveals two different kinds of particles, welded/aggregated, and single crystal like, and emphasizes the intra- and interparticle heterogeneities from the nano- to the microscale. It also detects within the imaging resolution (100 nm) substantial quantities of nanovoids hidden inside the bulk of two-thirds of the overall studied particles (around 3000), with an average value of 12.5%v per particle and a mean size of 148 nm. The powerful combination of both techniques helps prescreening and quantifying the defective nature of cathode material and thus anticipating their performance in electrode assembly/battery testing.

14.
Ultramicroscopy ; 173: 10-13, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27898297

RESUMO

We present a novel sample preparation method that allows correlative 3D X-ray Computed Nano-Tomography (CNT) and Focused Ion Beam Time-Of-Flight Secondary Ion Mass Spectrometry (FIB-TOF-SIMS) tomography to be performed on the same sample. In addition, our invention ensures that samples stay unmodified structurally and chemically between the subsequent experiments. The main principle is based on modifying the topography of the X-ray CNT experimental setup before FIB-TOF-SIMS measurements by incorporating a square washer around the sample. This affects the distribution of extraction field lines and therefore influences the trajectories of secondary ions that are now guided more efficiently towards the detector. As the result, secondary ion detection is significantly improved and higher, i.e. statistically better, signals are obtained.

15.
J Pharm Biomed Anal ; 112: 43-9, 2015 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-25951620

RESUMO

The objective of this study was to investigate the use of transmission hard X-ray nano-computed-tomography (nano-CT) for characterization of the pore structure and drug distribution in poly (lactic-co-glycolic acid) (PLGA) microspheres encapsulating bovine serum albumin and to study the correlation between drug distribution and burst release. The PLGA microspheres were fabricated using a double-emulsion method. The results of pore structure analysis accessed with nano-CT were compared with those acquired by scanning electron microscopy (SEM) and confocal laser scanning microscopy (CLSM). Surface pore interconnectivity and surface protein interconnectivity were obtained using combined nano-CT and pixel analysis. The correlation between surface protein interconnectivity with the initial burst release across various tested formulations was also analyzed. The size, shape, and distribution of the pores and protein could be clearly observed in the whole microsphere using nano-CT, whereas only the sectional information was observed using SEM or CLSM. Interconnected pores and surface connected pores could be clearly distinguished in nano-CT, which enables the quantitative analysis of surface pore interconnectivity and surface protein interconnectivity. The surface protein interconnectivity in different formulations correlated well with the burst release at 5-10h. Nano-CT provided a nondestructive, high-resolution, and three-dimensional analysis method to characterize the porous microsphere.


Assuntos
Ácido Láctico/química , Ácido Poliglicólico/química , Química Farmacêutica/métodos , Portadores de Fármacos/química , Sistemas de Liberação de Medicamentos/métodos , Emulsões/química , Dureza , Microscopia Eletrônica de Varredura/métodos , Microesferas , Tamanho da Partícula , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Porosidade , Soroalbumina Bovina/química , Propriedades de Superfície , Tomografia/métodos , Raios X
16.
J R Soc Interface ; 11(95): 20140126, 2014 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-24671938

RESUMO

We document the hygroscopic swelling and shrinkage of the central and the thickest secondary cell wall layer of wood (named S2) in response to changes in environmental humidity using synchrotron radiation-based phase contrast X-ray tomographic nanoscopy. The S2 layer is a natural fibre-reinforced nano-composite polymer and is strongly reactive to water. Using focused ion beam, micropillars with a cross section of few micrometres are fabricated from the S2 layer of the latewood cell walls of Norway spruce softwood. The thin neighbouring cell wall layers are removed to prevent hindering or restraining of moisture-induced deformation during swelling or shrinkage. The proposed experiment intended to get further insights into the microscopic origin of the anisotropic hygro-expansion of wood. It is found that the swelling/shrinkage strains are highly anisotropic in the transverse plane of the cell wall, larger in the normal than in the direction parallel to the cell wall's thickness. This ultrastructural anisotropy may be due to the concentric lamellation of the cellulose microfibrils as the role of the cellulose microfibril angle in the transverse swelling anisotropy is negligible. The volumetric swelling of the cell wall material is found to be substantially larger than the one of wood tissues within the growth ring and wood samples made of several growth rings. The hierarchical configuration in wood optimally increases its dimensional stability in response to a humid environment with higher scales of complexity.


Assuntos
Parede Celular/química , Picea/química , Água/química , Madeira/química , Anisotropia
17.
Acta Biomater ; 9(9): 8118-27, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23707503

RESUMO

We investigate the three-dimensional (3-D) organization of mineralized collagen fibrils in human cortical bone based on synchrotron X-ray phase nano-tomography images. In lamellar bone the collagen fibrils are assumed to have a plywood-like arrangement, but due to experimental limitations the 3-D fibril structure has only been deduced from section surfaces so far and the findings have been controversial. Breakthroughs in synchrotron tomographic imaging have given access to direct 3-D information on the bone structure at the nanoscale level. Using an autocorrelation-based orientation measure we confirm that the fibrils are unidirectional in quasi-planes of sub-lamellae and find two specific dominant patterns, oscillating and twisted plywoods coexisting in a single osteon. Both patterns exhibit smooth orientation changes between adjacent quasi-planes. Moreover, we find that the periodic changes in collagen fibril orientation are independent of fluctuations in local mass density. These data improve our understanding of the lamellar arrangement in bone and allow more detailed investigations of structure-function relationships at this scale, providing templates for bio-inspired materials. The presented methodology can be applied to non-destructive 3-D characterization of the sub-micron scale structure of other natural and artificial mineralized biomaterials.


Assuntos
Fêmur/química , Fêmur/ultraestrutura , Colágenos Fibrilares/ultraestrutura , Imageamento Tridimensional/métodos , Minerais/análise , Síncrotrons , Tomografia por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Fêmur/diagnóstico por imagem , Humanos , Técnicas In Vitro , Conformação Proteica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA