Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Neural Transm (Vienna) ; 128(8): 1205-1213, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34231038

RESUMO

BACKGROUND: Deep brain stimulation (DBS) of the globus pallidus internus (GPi) has become an accepted treatment for severe cervical dystonia (CD). Assessment of therapeutic efficacy of DBS mostly focused on head position at rest but hardly on limitations of head and neck mobility, which represent a functionally important impairment in CD. OBJECTIVE: We aimed to determine prospectively head and neck range of motion (ROM) preoperatively and during chronic bilateral GPi DBS in a series of 11 patients with idiopathic CD or segmental dystonia with prominent CD using a computerized motion analysis. METHODS: Maximum horizontal rotation of the head in the transverse plane and lateral inclination in the frontal plane were measured preoperatively and at a median of 7 months of chronic GPi DBS, using an ultrasound-based three-dimensional measuring system combined with surface electromyography of cervical muscles. RESULTS: Horizontal rotation of the head increased from 78.8° ± 31.5° (mean ± SD) preoperatively to 100.7° ± 24.7° with GPi DBS (p < 0.01), thereby improvement of head rotation to the anti-dystonic side (+ 14,2° ± 12,2°) was greater than to the pro-dystonic side (+ 7,8° ± 9,2°; p < 0.05). Movement-related agonistic-antagonistic EMG modulation during head rotation was enhanced with GPi DBS in both sternocleidomastoid (modulation index (MI) 35.8% ± 26.7% preoperatively vs. 67.3% ± 16.9% with GPi DBS, p < 0.01), and splenius capitis muscles (MI 1.9% ± 24.5% preoperatively vs. 44.8% ± 11.6% with GPi DBS, p < 0.01). CONCLUSION: Chronic bilateral GPi DBS significantly improves head ROM in CD, likely due to enhanced agonist-antagonist EMG activity with reduced co-contraction. Computerized motion analysis provides an objective measurement to assess the improvement of head and neck mobility in CD.


Assuntos
Estimulação Encefálica Profunda , Torcicolo , Globo Pálido , Humanos , Amplitude de Movimento Articular , Torcicolo/terapia , Resultado do Tratamento
2.
J Bodyw Mov Ther ; 38: 86-91, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38763621

RESUMO

BACKGROUND: Myofascial pain syndrome is a painful musculoskeletal condition with muscle spasm, referred pain, stiffness, restricted range of motion. Capacitive-resistive diathermy heats deep tissues by transferring energy through radiofrequency waves. Although this modality is used to treat various musculoskeletal disorders, there is no specific data on myofascial trigger points. Thus, we aimed to evaluate the effectiveness of capacitive-resistive diathermy on the myofascial trigger points. METHODS: Thirty-six volunteers with active myofascial trigger points were included. Patients were randomly and equally allocated into two groups. Group-1 is the capacitive-resistive diathermy treatment group; Group-2 is the placebo capacitive-resistive diathermy (PG). Visual analog scale (VAS), pain pressure threshold (PPT), neck disability index (NDI), neck range of motion (nROM), Short form-36 (SF-36) were used as outcomes before and after the intervention. RESULTS: In both groups, VAS, PPT, NDI score significantly improved within the groups (p < 0.05). The CRG showed a statistically significant improvement in nROM for flexion, extension, and rotation (p < 0.05). However, ROM increase in CRG is not superior to PG (p > 0.05). CONCLUSIONS: There was no significant difference between the two groups. We thought positive results in the PG might attributed to doing exercise. As a result, capacitive-resistive diathermy is not superior to exercise, but can be used as an adjuvant modality in myofascial trigger points treatment.


Assuntos
Síndromes da Dor Miofascial , Medição da Dor , Amplitude de Movimento Articular , Pontos-Gatilho , Humanos , Síndromes da Dor Miofascial/terapia , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Diatermia/métodos
3.
Front Psychiatry ; 14: 1200091, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37324814

RESUMO

Objectives: Opium smoking is commonly practiced via traditional and novel routes in Iran. Both smoking methods are practiced in a non-ergonomic position. According to previous studies and our hypothesis, it can be potentially harmful to the cervical spine. Thus, the present study aimed to investigate the relationship between opium smoking and neck range of motion and neck muscle strength. Methods: In this cross-sectional and correlational study, the range of motion and strength of the neck muscles of 120 men with drug use disorder were measured by a CROM goniometer and a hand-held dynamometer. Other data gathering was performed using a demographic questionnaire, the Maudsley Addiction Profile, and the Persian version of Leeds Dependence Questionnaire. The obtained data were analyzed by Shapiro-Wilks test, Pearson's correlation coefficient and stepwise linear regression. Results: There was no significant correlation between the age of drug use onset and range of motion and muscle strength of the neck; however, the daily duration of opium smoking and the number of years of opium smoking were inversely and significantly correlated with the range of motion and muscle strength of the neck in some directions. Daily opium smoking time for decreasing in neck range of motion and total duration of opium smoking for reduction of neck muscles strength are stronger predictor variables. Conclusion: Opium smoking by traditional routes causes non-ergonomic positions and has a moderate significant correlation with reduced range of motion and neck muscle strength, in Iran. Highlights: - The harm of drug use disorder is not only AIDS and hepatitis, and harm reduction programs should go beyond the prevention of AIDS and hepatitis. According to more than 90% of smoking use of drug compared to other methods (oral and injectable, etc.) musculoskeletal disorders caused by the smoking use of drugs, have a greater cost burden in reducing the quality of life and the need for rehabilitation.- Drug abuse treatment and harm reduction programs should focus more seriously on replacing smoking use of drugs with oral medications assisted treatment.- Although in Iran and some countries in the region, a large number of people smoke opium for many years and sometimes all their lives, daily in a completely non-ergonomic position, but studying the deformation of the posture and musculoskeletal disorders related to the body position in them, is not a scientific concern and neither physical therapy researchers have paid attention to it nor addiction researchers.- Neck muscles strength and range of motion in opium addicts are correlated to the number of years of opium smoking and daily minutes of opium smoking, but not to its oral use.- There is no significant correlation between the onset age of continues and permanent opium smoking and substance dependence severity with neck range of motion and muscles strength.- People with drug use disorder (especially smoking users) as a large group of vulnerable people, should be the target population of musculoskeletal disorders researchers and addiction harm reduction researchers, and more experimental, comparative, cohort, etc. researches should be designed and implemented for them.

4.
J Biomech ; 48(4): 721-724, 2015 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-25636855

RESUMO

An inertial sensor-embedded virtual reality (VR) head-mounted display, the Oculus Rift (the Rift), monitors head movement so the content displayed can be updated accordingly. While the Rift may have potential use in cervical spine biomechanics studies, its accuracy in terms of cervical spine mobility measurement has not yet been validated. In the current study, a VR environment was designed to guide participants to perform prescribed neck movements. The cervical spine kinematics was measured by both the Rift and a reference motion tracking system. Comparison of the kinematics data between the Rift and the tracking system indicated that the Rift can provide good estimates on full range of motion (from one side to the other side) during the performed task. Because of inertial sensor drifting, the unilateral range of motion (from one side to neutral posture) derived from the Rift is more erroneous. The root-mean-square errors over a 1-min task were within 10° for each rotation axis. The error analysis further indicated that the inertial sensor drifted approximately 6° at the beginning of a trial during the initialization. This needs to be addressed when using the Rift in order to more accurately measure cervical spine kinematics. It is suggested that the front cover of the Rift should be aligned against a vertical plane during its initialization.


Assuntos
Vértebras Cervicais/fisiologia , Movimento/fisiologia , Pescoço/fisiologia , Amplitude de Movimento Articular/fisiologia , Interface Usuário-Computador , Adulto , Idoso , Fenômenos Biomecânicos , Feminino , Movimentos da Cabeça/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Reprodutibilidade dos Testes , Rotação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA