Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 37(10): 1214-1219, 2023 Oct 15.
Artigo em Chinês | MEDLINE | ID: mdl-37848315

RESUMO

Objective: To explore the feasibility and early effectiveness of computer-simulated osteotomy based on the health-side combined with guide plate technique in the treatment of cubitus varus deformity in adolescents. Methods: The clinical data of 23 patients with cubitus varus deformity who met the selection criteria between June 2019 and February 2023 were retrospectively analyzed. There were 17 males and 6 females, ranging in age from 4 to 16 years with an average of 8.5 years. The time from injury to operation was 1-4 years. The angle of distal humerus rotation was defined by humeral head posterior inclination angle using low radiation dose CT to scan the patient's upper extremity data at one time, and the preoperative rotation of the distal humerus on the affected side was (33.82±4.39)°. The CT plain scan data were imported into 9yuan3D digital orthopaedic system (V3.34 software) to reconstruct three-dimensional images of both upper extremities. The simulated operation was performed with the healthy upper extremity as the reference, the best osteotomy scheme was planned, overlapped and compared, and the osteotomy guide plate was prepared. The patients were followed up regularly after operation, and the formation of callus in the osteotomy area was observed by X-ray examination. Before and after operation, the carrying angle of both upper extremities (the angle of cubitus valgus was positive, and the angle of cubitus varus was negative) and anteversion angle were measured on X-ray and CT images. At the same time, the flexion and extension range of motion of elbow joint and the external rotation range of motion of upper extremity were measured, and Mayo score was used to evaluate the function of elbow joint. Results: The operation time ranged from 34 to 46 minutes, with an average of 39 minutes. All patients were followed up 5-26 months, with a mean of 14.9 months. All the incisions healed by first intention after the operation; 2 patients had nail path irritation symptoms after Kirschner wire fixation, which improved after dressing change; no complication such as breakage and loosening of internal fixators occurred after regular X-ray review. Continuous callus formed at the osteotomy end at 4 weeks after operation, and the osteotomy end healed at 8-12 weeks after operation. At last follow-up, the carrying angle, anteversion angle, external rotation range of motion, and extension and flexion range of motion of the elbow joint of the affected side significantly improved when compared with preoperative ones ( P<0.05). Except for the extension range of motion of the healthy elbow joint ( P<0.05), there was no significant difference in other indicators between the two sides ( P>0.05). At last follow-up, the Mayo elbow score was 85-100, with an average of 99.3; 22 cases were excellent, 1 case was good, and the excellent and good rate was 100%. Conclusion: Computer-simulated osteotomy based on health-side combined with guide plate technique for treating cubitus varus deformity in adolescents can achieve precise osteotomy, which has the advantages of short operation time and easy operation, and the short-term effectiveness is satisfactory.


Assuntos
Articulação do Cotovelo , Fraturas do Úmero , Deformidades Articulares Adquiridas , Deformidades Congênitas dos Membros , Masculino , Feminino , Humanos , Adolescente , Pré-Escolar , Criança , Cotovelo , Fraturas do Úmero/cirurgia , Estudos Retrospectivos , Deformidades Articulares Adquiridas/etiologia , Deformidades Articulares Adquiridas/cirurgia , Articulação do Cotovelo/cirurgia , Osteotomia/métodos , Cabeça do Úmero , Amplitude de Movimento Articular , Computadores , Resultado do Tratamento
2.
J Orthop Surg Res ; 18(1): 315, 2023 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-37095575

RESUMO

BACKGROUND: Patients with developmental dysplasia of the hip (DDH) have complex proximal femoral deformities, and orthopedic surgery lacks objectivity. Expectations for surgical outcomes are often not achieved, and postoperative problems are common. Using 3D-printed technology in orthopedics offers a novel approach to precise and individualized treatment in modern orthopedics. The aim of this study was to investigate the value of the application of 3D-printed osteotomy guide plates in femoral osteotomy. The clinical indices of femoral osteotomy in children with DDH using 3D-printed osteotomy guide plates were compared with those of traditional osteotomy. METHODS: The clinical data of children with DDH who underwent open reduction and Salter pelvic osteotomy combined with femoral osteotomy from September 2010 to September 2020 were retrospectively collected and analyzed. Based on the inclusion and exclusion criteria, a total of 36 patients were included in the study: 16 in the guide plate group and 20 in the conventional group. Operation time (total), operation time (femoral side), X-ray fluoroscopy times (total), X-ray fluoroscopy times (femoral side) and intraoperative blood loss were analyzed and compared between the two groups. Comparison of treatment-related indicators such as postoperative neck-shaft angle, postoperative anteversion angle, hospitalization time, and hospitalization expenses is made between the two groups. The two groups of patients were evaluated at the last follow-up using the McKay clinical evaluation criteria. RESULTS: Between the two groups, there were significant differences in operation time (total), operation time (femoral side), X-ray fluoroscopy times (total), X-ray fluoroscopy times (femoral side) and intraoperative blood loss (P < 0.05). The postoperative neck-shaft angle, postoperative anteversion angle, hospitalization time and hospitalization expenses did not differ significantly (P > 0.05). The MacKay clinical evaluation did not significantly differ at the most recent follow-up (P > 0.05). CONCLUSIONS: Children with DDH undergoing proximal femoral osteotomy using 3D-printed osteotomy guide plates benefit from a simpler surgical procedure, shorter operative time, less bleeding and less radiation exposure during surgery. This technique is of great clinical value.


Assuntos
Luxação Congênita de Quadril , Humanos , Criança , Estudos Retrospectivos , Luxação Congênita de Quadril/cirurgia , Perda Sanguínea Cirúrgica , Osteotomia/métodos , Impressão Tridimensional , Resultado do Tratamento
3.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 36(7): 811-816, 2022 Jul 15.
Artigo em Chinês | MEDLINE | ID: mdl-35848175

RESUMO

Objective: To investigate the mid-term effectiveness of three-dimensional (3D) printed osteotomy guide plate and personalized prosthesis in knee-preserving tumor resection. Methods: The clinical data of 12 patients who underwent knee-preserving tumor resection and reconstruction with 3D printed osteotomy guide plate and personalized prosthesis between September 2016 and October 2018 were retrospectively analyzed. There were 7 males and 5 females. The age ranged from 7 to 59 years, with a median of 44.5 years. There were 11 cases of osteosarcoma and 1 case of fibrosarcoma, all of which were Enneking grade ⅡB. The distance from the tumor to the joint surface was 5.5-8.2 cm, with an average of 6.94 cm. Incision healing, tumor recurrence, periprosthetic fracture, and aseptic loosening were observed after operation. The Musculoskeletal Tumor Society (MSTS) scoring system was used to evaluate the function of the patients, and the knee flexion range of motion was measured. Results: The 12 patients were followed up 41-66 months, with an average of 54.5 months. The length of osteotomy ranged from 14 to 26 cm, with an average of 22.08 cm. Except for 2 patients with superficial infection of incision tissue, no deep infection involving the prosthesis occurred, no patient underwent revision surgery because of prosthesis infection. During the follow-up, local recurrence occurred in 2 cases and distant metastasis occurred in 3 cases. The overall disease-free survival rate was 58.3%. Two patients died of lung metastasis, and the overall survival rate was 83.3%. One patient underwent amputation due to local recurrence, and 1 patient underwent total knee arthroplasty due to prosthesis rupture. No aseptic loosening of the prosthesis and periprosthetic fracture occurred during the follow-up, and the overall prosthesis survival rate was 83.3%. At last follow-up, 10 patients obtained satisfactory knee flexion range of motion that ranged from 95° to 125°, with an average of 110°. Two children could not cooperate with early rehabilitation treatment due to pain, and the knee flexion range of motion was not ideal (50°, 75°). All patients achieved acceptable lower limb function with MSTS scores ranged from 26 to 30, with an average of 28. All patients walked without crutches. Conclusion: The treatment of malignant bone tumors around the knee joint with 3D printed osteotomy guide plate and personalized prosthesis can preserve the articular surface, obtain good limb function, reduce the risk of aseptic loosening of prosthesis, and achieve better mid-term effectiveness.


Assuntos
Artroplastia do Joelho , Membros Artificiais , Neoplasias Ósseas , Prótese do Joelho , Fraturas Periprotéticas , Adolescente , Adulto , Neoplasias Ósseas/cirurgia , Criança , Feminino , Humanos , Articulação do Joelho/cirurgia , Extremidade Inferior/cirurgia , Masculino , Pessoa de Meia-Idade , Osteotomia , Fraturas Periprotéticas/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
4.
J Orthop Surg Res ; 14(1): 353, 2019 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-31706346

RESUMO

BACKGROUND: This present study is aimed to retrospectively assess the efficacy of three-dimensional (3D) printing assisted osteotomy guide plate in accurate osteotomy of adolescent cubitus varus deformity. MATERIAL AND METHODS: Twenty-five patients (15 males and 10 females) with the cubitus varus deformity from June 2014 to December 2017 were included in this study and were enrolled into the conventional group (n = 11) and 3D printing group (n = 14) according to the different surgical approaches. The operation time, intraoperative blood loss, osteotomy degrees, osteotomy end union time, and postoperative complications between the two groups were observed and recorded. RESULTS: Compared with the conventional group, the 3D printing group has the advantages of shorter operation time, less intraoperative blood loss, higher rate of excellent correction, and higher rate of the parents' excellent satisfaction with appearance after deformity correction (P < 0.001, P < 0.001, P = 0.019, P = 0.023). Nevertheless, no significant difference was presented in postoperative carrying angle of the deformed side and total complication rate between the two groups (P = 0.626, P = 0.371). CONCLUSIONS: The operation assisted by 3D printing osteotomy guide plate to correct the adolescent cubitus varus deformity is feasible and effective, which might be an optional approach to promote the accurate osteotomy and optimize the efficacy.


Assuntos
Placas Ósseas , Articulação do Cotovelo/diagnóstico por imagem , Fraturas do Úmero/diagnóstico por imagem , Fraturas do Úmero/cirurgia , Osteotomia/métodos , Impressão Tridimensional , Adolescente , Placas Ósseas/tendências , Articulação do Cotovelo/anormalidades , Feminino , Seguimentos , Humanos , Masculino , Osteotomia/tendências , Impressão Tridimensional/tendências , Estudos Retrospectivos , Resultado do Tratamento
5.
J Orthop Surg Res ; 14(1): 327, 2019 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-31639044

RESUMO

INTRODUCTION: To analyze the application of 3D printed osteotomy guide plate-assisted total knee arthroplasty (TKA) for valgus knee deformity. METHODS: The clinical data of 20 patients with valgus knee deformity admitted to our hospital from April 2012 to April 2017 were collected and analyzed. According to the treatment method, these patients were divided into two groups: 3D printed osteotomy guide plate-assisted TKA (combined treatment group, n = 10) and TKA (treatment group, n = 10). The operation time, intraoperative bleeding volume, postoperative mean femorotibial angle (MFTA), and Knee Society Score (KSS) of the two groups were statistically analyzed. RESULTS: Compared with the treatment group, the operation time was significantly shorter (P < 0.05), the intraoperative blood loss and postoperative MFTA were significantly decreased (P < 0.05), and the clinical and functional scores were significantly increased (P < 0.05) in the combined treatment group. CONCLUSION: 3D printed osteotomy guide plate-assisted TKA for valgus knee deformity is more effective than TKA alone.


Assuntos
Artroplastia do Joelho/métodos , Placas Ósseas , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteotomia/métodos , Impressão Tridimensional , Idoso , Feminino , Humanos , Articulação do Joelho/anormalidades , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA