Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
J Anaesthesiol Clin Pharmacol ; 40(1): 75-81, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38666171

RESUMO

Background and Aims: The laryngeal mask airway ProSeal (PLMA) insertion should be easy, fast, and atraumatic. Most studies have been done on adults who cannot be considered as the reflection of pediatric patients. In this study, we compared the first attempt success rate of three techniques of PLMA insertion: introducer, 90° rotation, and pharyngoscopy technique in the pediatric population. Material and Methods: In this prospective comparative randomized study, a total of 135 patients of American Society of Anesthesiology grade I and II, aged three to eleven years, with normal airways scheduled for elective surgery, were randomly allocated into three groups: introducer, 90° rotation, and pharyngoscopy group. Parameters evaluated were: first attempt insertion success rate, insertion time, ease of insertion score, hemodynamic parameters, oropharyngeal seal pressure, manipulations, PLMA blood staining, postoperative sore throat, and hoarseness. Results: First attempt insertion success rate was higher in the 90° rotation (97.78%) and pharyngoscopy (97.78%) group as compared to the introducer group (93.33%). But the result was not statistically significant. PLMA insertion time was the least in the rotation group, followed by the pharyngoscopy and introducer group (P < 0.0001). Mean arterial pressure and heart rate were significantly raised in the pharyngoscopy versus rotation group and the introducer versus 90° rotation group after PLMA insertion. Oropharyngeal seal pressure was significantly higher in the introducer as compared to the rotation group (P = 0.007). Conclusion: All three techniques had a high first-attempt insertion success rate. As the rotation technique had the best result in insertion time and hemodynamic response, it may be considered a good alternative to pharyngoscopy and introducer technique in pediatric patients of age three to eleven years with a normal airway.

2.
BMC Anesthesiol ; 16(1): 57, 2016 08 05.
Artigo em Inglês | MEDLINE | ID: mdl-27494933

RESUMO

BACKGROUND: The sniffing position (neck flexion by head elevation and head extension) is commonly used for insertion of a laryngeal mask airway. However, the appropriate degrees of head elevation and head extension are unclear. In the present study, the success rate of ProSeal™ laryngeal mask airway (LMA ProSeal) insertion using two degrees of head elevation was evaluated. METHODS: This prospective randomized, controlled study included 80 adult patients aged 18 to 90 years. In the 3 cm (n = 40) and 6 cm (n = 40) groups, the LMA ProSeal was inserted while the head was elevated 3 cm and 6 cm, respectively, using a pillow of the corresponding height. The success rate, and incidence of blood staining on cuff, sore throat and hoarseness were assessed. The alignments of laryngeal and oral axes were also evaluated. RESULTS: The first attempt success rate was higher in the 3 cm than the 6 cm group (87 % vs. 60 %, P = 0.014). In 86 % of patients in the 6 cm group and 50 % of patients in the 3 cm group in whom the second attempt failed, the third insertion attempt was successful by using a pillow height of the opposite group. The alignments of the two axes were not different between the two groups (P > 0.05). CONCLUSIONS: The first attempt success rate of ProSeal laryngeal mask insertion was higher with 3 cm than 6 cm head elevation in adult patients. TRIAL REGISTRATION: Identifiers: NCT02058030 (08/05/2015), Unique Protocol ID: phdkim1.


Assuntos
Cabeça , Intubação Intratraqueal/métodos , Máscaras Laríngeas/efeitos adversos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Hemorragia/epidemiologia , Hemorragia/prevenção & controle , Rouquidão/epidemiologia , Rouquidão/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Faringite/epidemiologia , Faringite/prevenção & controle , Estudos Prospectivos , República da Coreia/epidemiologia , Método Simples-Cego , Decúbito Dorsal , Adulto Jovem
3.
J Anaesthesiol Clin Pharmacol ; 30(2): 183-7, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24803754

RESUMO

BACKGROUND: We compared i-gel and ProSeal laryngeal mask airway (PLMA) regarding time taken for insertion, effective seal, fiberoptic view of larynx, ease of Ryle's tube insertion, and postoperative sore throat assessment. MATERIALS AND METHODS: In a prospective, randomized manner, 48 adult patients of American Society of Anesthesiologists I-II of either gender between 18 and 60 years presenting for a short surgical procedure were assigned to undergo surgery under general anesthesia on spontaneous ventilation using either the i-gel or PLMA. An experienced nonblinded anesthesiologist inserted appropriate sized i-gel or PLMA in patients using standard insertion technique and assessed the intraoperative findings of the study regarding regarding time taken for respective device insertion, effective seal, fiberoptic view of larynx, ease of Ryle's tube insertion, and postoperative sore throat assessment. Postoperative assessment of sore throat was done by blinded anesthesia resident. RESULTS: The time required for insertion of i-gel was lesser (21.98 ± 5.42 and 30.60 ± 8.51 s in Group I and Group P, respectively; P = 0.001). Numbers of attempts for successful insertions were comparable and in majority, device was inserted in first attempt. The mean airway leak pressures were comparable. However, there were more number of patients in Group P who had airway leak pressure >20 cm H2O. The fiberoptic view of glottis, ease of Ryle's tube insertion, and incidence of complications were comparable. CONCLUSION: Time required for successful insertion of i-gel was less in adult patients undergoing short surgical procedure under general anesthesia on spontaneous ventilation. Patients with airway leak pressure >20 cm H2O were more in PLMA group which indicates its better suitability for controlled ventilation.

4.
J Res Med Sci ; 17(2): 148-53, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23264788

RESUMO

BACKGROUND: We aimed to compare hemodynamic and endocrine alterations caused by stress response due to Proseal laryngeal mask airway and endotracheal tube usage in laparoscopic cholecystectomy. MATERIALS AND METHODS: Sixty-three ASA I-II patients scheduled for elective laparoscopic cholecystectomy were included in the study. Patients were randomly allocated into two groups of endotracheal tube and Proseal laryngeal mask airway. Standard general anaesthesia was performed in both groups with the same drugs in induction and maintenance of anaesthesia. After anaesthesia induction and 20 minutes after CO(2) insufflations, venous blood samples were obtained for measuring adrenalin, noradrenalin, dopamine and cortisol levels. Hemodynamic and respiratory parameters were recorded at the 1(st), 5(th), 15(th), 30(th) and 45(th) minutes after the insertion of airway devices. RESULTS: No statistically significant differences in age, body mass index, gender, ASA physical status, and operation time were found between the groups (p > 0.05). Changes in hemodynamic and respiratory parameters were not statistically significant when compared between and within groups (p > 0.05). Although no statistically significant differences were observed between and within groups when adrenalin, noradrenalin and dopamine values were compared, serum cortisol levels after CO(2) insufflation in PLMA group were significantly lower than the ETT group (p = 0.024). When serum cortisol levels were compared within groups, cortisol levels 20 minutes after CO(2) insufflation were significantly higher (46.1 (9.5-175.7) and 27.0 (8.3-119.4) in the ETT and PLMA groups, respectively) than cortisol levels after anaesthesia induction (11.3 (2.8-92.5) and 16.6 (4.4-45.4) in the ETT and PLMA groups, respectively) in both groups (p = 0.001). CONCLUSION: PLMA usage is a suitable, effective and safe alternative to ETT in laparoscopic cholecystectomy patients with lower metabolic stress.

5.
Cureus ; 14(9): e28921, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36237751

RESUMO

ProSealTM Laryngeal Mask Airway (PLMA) (Teleflex Medical, Westmeath, Ireland) is a versatile and popular reusable supraglottic airway device. The manufacturer advises maximum reuse of up to 40 times. However, excessive reuse of the device can cause rare complications. Here, we report a rather uncommon complication of intraoperative cuff rupture of a PLMA probably due to the combination of a forceful metal introducer tip insertion and nitrous oxide-based anaesthesia.

6.
J Orthop Surg Res ; 15(1): 551, 2020 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-33228707

RESUMO

BACKGROUND: Posterior cervical pedicle screw (CPS) internal fixation has better biomechanical stability than other posterior cervical fixation methods. However, this technique is limited in clinical practice due to the complex anatomical structure and the adjacent relationship of the cervical pedicle, and the high risk of neurovascular injury. The purpose of this study was to describe a novel subaxial CPS insertion technique assisted by a special angular scale using lateral mass as a reference marker and to evaluate the accuracy of CPS placement and the distribution characteristics of CPS misplacement. METHODS: A total of 36 patients with subaxial cervical spine diseases who underwent posterior CPS fixation were consecutively selected. The optimal entry point on the posterior surface of the lateral mass was identified on the three-dimensional cervical model reconstructed from preoperative computed tomography (CT) images. The pedicle transverse angle (PTA) and pedicle-lateral mass angle (PLMA) were measured on the transverse and sagittal CT images respectively. The pedicle screws were inserted according to the preoperatively planned entry point and angles. We analysed the postoperative CT images for CPS misplacement rates and perforation directions following the Lee classification. RESULTS: Overall, 177 pedicle screws were inserted, of which 119 (67.2%) were classified as grade 0, 43 (24.3%) as grade 1, 12 (6.8%) as grade 2 and 3 (1.7%) as grade 3 by the postoperative CT images. The accuracy rate of CPS placement was 91.5%. Of the 15 misplaced pedicle screws (grades 2 and 3), 11 were lateral pedicle perforations, 3 were superior perforations and 1 was an inferior perforation. There were no neurovascular injuries related to CPS misplacement. CONCLUSIONS: With our technique, the optimal entry point and two angles (PTA and PLMA) were identified for CPS insertion. The novel CPS insertion technique assisted by a special angular scale provides high accuracy and few complications.


Assuntos
Vértebras Cervicais/cirurgia , Parafusos Pediculares , Doenças da Coluna Vertebral/cirurgia , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Adulto , Idoso , Vértebras Cervicais/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Traumatismos dos Nervos Periféricos/etiologia , Traumatismos dos Nervos Periféricos/prevenção & controle , Sensibilidade e Especificidade , Doenças da Coluna Vertebral/diagnóstico por imagem , Fusão Vertebral/efeitos adversos , Tomografia Computadorizada por Raios X
7.
ACS Appl Mater Interfaces ; 11(24): 21323-21333, 2019 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-31134794

RESUMO

In this paper, two series of poly(sulfobetaine methacrylate)- b-poly(lauryl methacrylate) (PSBMA- b-PLMA) diblock copolymers were prepared to investigate the core-shell reversion of amphiphilic copolymers. Experimental results proved that the PSBMA- b-PLMA copolymers can be self-assembled as core-shell nanoparticles in chloroform. Moreover, 1H NMR spectra and contact angle measurements revealed that there is a transitional PSBMA/PLMA block ratio of 0.6, above which the nanoparticles are capable of switching their core and shell in aqueous solution. Consequently, nanoparticles with PSBMA/PLMA block ratios above 0.6 showed superior antifouling and antibacterial abilities to those with block ratios below 0.4. Moreover, it was also found that the block chain length plays an important role in core-shell reversion as evidenced by 1H NMR spectra, water contact angle, and antifouling tests. As a result, coatings fabricated with the PLMA100 series of nanoparticles showed better antifouling abilities than those of the PLMA150 series at the same block ratio probably because of the thinner shell of PLMA100 copolymers. PSBMA100- b-PLMA100 was proved to be the best candidate for the fabrication of antifouling coatings as it exhibited the highest efficacy in antibacterial adhesion and antiprotein adsorption. This study provided a facile method to fabricate antifouling coatings by developing amphiphilic diblock copolymers with tuned hydrophobic/hydrophilic block ratio, block chain length, etc.

8.
Front Mol Biosci ; 5: 91, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30483512

RESUMO

PII, a homotrimeric very ancient and highly widespread (bacteria, archaea, plants) key sensor-transducer protein, conveys signals of abundance or poorness of carbon, energy and usable nitrogen, converting these signals into changes in the activities of channels, enzymes, or of gene expression. PII sensing is mediated by the PII allosteric effectors ATP, ADP (and, in some organisms, AMP), 2-oxoglutarate (2OG; it reflects carbon abundance and nitrogen scarcity) and, in many plants, L-glutamine. Cyanobacteria have been crucial for clarification of the structural bases of PII function and regulation. They are the subject of this review because the information gathered on them provides an overall structure-based view of a PII regulatory network. Studies on these organisms yielded a first structure of a PII complex with an enzyme, (N-acetyl-Lglutamate kinase, NAGK), deciphering how PII can cause enzyme activation, and how it promotes nitrogen stockpiling as arginine in cyanobacteria and plants. They have also revealed the first clear-cut mechanism by which PII can control gene expression. A small adaptor protein, PipX, is sequestered by PII when nitrogen is abundant and is released when is scarce, swapping partner by binding to the 2OG-activated transcriptional regulator NtcA, co-activating it. The structures of PII-NAGK, PII-PipX, PipX alone, of NtcA in inactive and 2OG-activated forms and as NtcA-2OG-PipX complex, explain structurally PII regulatory functions and reveal the changing shapes and interactions of the T-loops of PII depending on the partner and on the allosteric effectors bound to PII. Cyanobacterial studies have also revealed that in the PII-PipX complex PipX binds an additional transcriptional factor, PlmA, thus possibly expanding PipX roles beyond NtcA-dependency. Further exploration of these roles has revealed a functional interaction of PipX with PipY, a pyridoxal-phosphate (PLP) protein involved in PLP homeostasis whose mutations in the human ortholog cause epilepsy. Knowledge of cellular levels of the different components of this PII-PipX regulatory network and of KD values for some of the complexes provides the basic background for gross modeling of the system at high and low nitrogen abundance. The cyanobacterial network can guide searches for analogous components in other organisms, particularly of PipX functional analogs.

9.
J Clin Anesth ; 35: 502-508, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27871584

RESUMO

STUDY OBJECTIVE: To determine quantitative differences in several routinely measured ventilation parameters using a standardized anesthetic technique and 3 different ventilation modalities in patients younger than 1 year with a ProSeal laryngeal mask airway (PLMA). DESIGN: Randomized prospective study. SETTING: Tertiary care pediatric hospital. PATIENTS: Thirty-nine American Society Anesthesiologists classifications 1 to 2, pediatric patients younger than 1 year. INTERVENTIONS: Three different ventilation strategies (spontaneous ventilation [SV], pressure support ventilation [PSV], and pressure-controlled ventilation [PCV]) were randomly applied to patients who underwent a standardized mask induction with sevoflurane/oxygen and propofol 2 mg/kg and fentanyl 2 µg/kg administered intravenously followed by PLMA insertion. Patients were maintained on sevoflurane and N2O. MEASUREMENTS: We measured the differences in end-tidal CO2 (etco2), tidal volume (TV), and respiratory rate (RR) over time between SV, PSV, and PCV. These data were recorded at 5-minute intervals. MAIN RESULTS: etco2 (mm Hg) was not significantly higher in the SV vs PSV (P=2.11) and SV vs PCV (P=.24). TV (mL/kg) was significantly lower in SV vs PSV (P<.005) and SV vs PCV (P<.005). RR was not significantly higher in SV vs PSV (P=.43), but was significantly higher in SV vs PCV (P<.005). Three patients in the SV group and 1 patient in the PSV group failed to initiate SV and required PCV and were thus excluded from analysis. CONCLUSIONS: All 3 modes of ventilation using a PLMA were safe in children younger than 1 year. Although we did not observe a statistically significant increase in etco2, differences in TV and RR, and the small but significant incidence of apnea may make PSV or PCV more optimal ventilation strategies in children younger than 1 year when using a PLMA.


Assuntos
Máscaras Laríngeas , Respiração Artificial/instrumentação , Feminino , Humanos , Lactente , Masculino , Respiração Artificial/métodos , Testes de Função Respiratória/métodos , Testes de Função Respiratória/estatística & dados numéricos , Taxa Respiratória , Volume de Ventilação Pulmonar
10.
Front Microbiol ; 7: 1677, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27840625

RESUMO

Cyanobacteria, phototrophic organisms that perform oxygenic photosynthesis, perceive nitrogen status by sensing 2-oxoglutarate levels. PII, a widespread signaling protein, senses and transduces nitrogen and energy status to target proteins, regulating metabolism and gene expression. In cyanobacteria, under conditions of low 2-oxoglutarate, PII forms complexes with the enzyme N-acetyl glutamate kinase, increasing arginine biosynthesis, and with PII-interacting protein X (PipX), making PipX unavailable for binding and co-activation of the nitrogen regulator NtcA. Both the PII-PipX complex structure and in vivo functional data suggested that this complex, as such, could have regulatory functions in addition to PipX sequestration. To investigate this possibility we performed yeast three-hybrid screening of genomic libraries from Synechococcus elongatus PCC7942, searching for proteins interacting simultaneously with PII and PipX. The only prey clone found in the search expressed PlmA, a member of the GntR family of transcriptional regulators proven here by gel filtration to be homodimeric. Interactions analyses further confirmed the simultaneous requirement of PII and PipX, and showed that the PlmA contacts involve PipX elements exposed in the PII-PipX complex, specifically the C-terminal helices and one residue of the tudor-like body. In contrast, PII appears not to interact directly with PlmA, possibly being needed indirectly, to induce an extended conformation of the C-terminal helices of PipX and for modulating the surface polarity at the PII-PipX boundary, two elements that appear crucial for PlmA binding. Attempts to inactive plmA confirmed that this gene is essential in S. elongatus. Western blot assays revealed that S. elongatus PlmA, irrespective of the nitrogen regime, is a relatively abundant transcriptional regulator, suggesting the existence of a large PlmA regulon. In silico studies showed that PlmA is universally and exclusively found in cyanobacteria. Based on interaction data, on the relative amounts of the proteins involved in PII-PipX-PlmA complexes, determined in western assays, and on the restrictions imposed by the symmetries of trimeric PII and dimeric PlmA molecules, a structural and regulatory model for PlmA function is discussed in the context of the cyanobacterial nitrogen interaction network.

11.
ACS Appl Mater Interfaces ; 7(46): 25669-78, 2015 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-26468765

RESUMO

Aluminum oxide nanoparticles (NPs) were surface-modified by poly(lauryl methacrylate) (PLMA) using surface-initiated atom-transfer radical polymerization (SI-ATRP) of lauryl methacrylate. Nanocomposites were obtained by mixing the grafted NPs in a low-density polyethylene (LDPE) matrix in different ratios. First, the NPs were silanized with different aminosilanes, (3-aminopropyl)triethoxysilane, and 3-aminopropyl(diethoxy)methylsilane (APDMS). Subsequently, α-BiB, an initiator for SI-ATRP, was attached to the amino groups, showing higher immobilization ratios for APDMS and confirming that fewer self-condensation reactions between silanes took place. In a third step SI-ATRP of LMA at different times was performed to render PLMA-grafted NPs (NP-PLMAs), showing good control of the polymerization. Reactions were conducted for 20 to 60 min, obtaining a range of molecular weights between 23 000 and 83 000 g/mol, as confirmed by size-exclusion chromoatography of the cleaved grafts. Nanocomposites of NP-PLMAs at low loadings in LDPE were prepared by extrusion. At low loadings, 0.5 wt % of inorganic content, the second yield point, storage, and loss moduli increased significantly, suggesting an improved interphase as an effect of the PLMA grafts. These observations were also confirmed by an increase in transparency of the nanocomposite films. At higher loadings, 1 wt % of inorganics, the increasing amount of PLMA gave rise to the formation of small aggregates, which may explain the loss of mechanical properties. Finally, dielectric measurements were performed, showing a decrease in tan δ values for LDPE-NP-PLMAs, as compared to the nanocomposites containing unmodified NP, thus indicating an improved interphase between the NPs and LDPE.

12.
J Clin Diagn Res ; 8(3): 80-4, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24783088

RESUMO

INTRODUCTION: Supraglottic devices have mostly eliminated the need of hemodynamically stressful routine endotracheal intubation for ambulatory surgeries. We aimed to compare hemodynamics- like blood pressure (BP) and heart rate (HR) alterations caused by stress response due to i-gel™ and LMA-ProSeal™ usage in Day care surgeries. Secondary outcomes included ease of insertion, time and number of attempts for the placement of devices. MATERIALS AND METHODS: From April 2008 to July 2009, Sixty adult ASA I-II patients of either sex, aged 20-30, were randomly allocated into two groups (Group i-gel (n=30) receiving i-gel and Group PLMA (n=30) receiving LMA-ProSeal for airway maintenance) undergoing day care surgical procedures under general anaesthesia (GA).The ease of insertion and time taken for placement of device, postoperative complications were assessed. Haemodynamic parameters (HR, BP) were noted. It was a prospective, double blinded, and randomized controlled study. Parametric data were analyzed with the unpaired t-test and non-parametric data were analyzed with the Chi-square test. Unless otherwise stated, data are presented as mean (+ SD). p <0.05 was considered statistically significant. RESULTS: Demographically both the groups were similar. i-gel was more easily inserted than LMA-ProSeal (90% vs. 83.33% respectively). i-gel insertion time was shorter than PLMA (14.9 vs. 20.0 sec respectively) and was statistically significant. Hemodynamics (HR, BP) were less altered in i-gel than PLMA and the results were statistically significant (p <0.05). CONCLUSION: i-Gel; a relatively newer and cheap supraglottic device; insertion is easier and quicker as well as hemodynamically less stressful when compared with LMA-ProSeal in a day care setting.

13.
Korean J Anesthesiol ; 63(6): 510-4, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23277811

RESUMO

BACKGROUND: The relatively recently developed I-gel (Intersurgical Ltd., Workingham, England) is a supraglottic airway device designed for single-use that, unlike conventional LMAs, does not require an inflatable cuff. In addition, the I-gel, much like the Proseal LMA (PLMA), has a gastric drainage tube associated with an upper tube for decompression of the stomach, thereby avoiding acid reflux and decreasing the risk of pulmonary absorption. The purpose of this study was to compare PLMA and I-gel devices in patients undergoing gynecological laparoscopy based on sealing pressure before and during pneumoperitoneum, insertion time, and gas exchange. METHODS: Following Institutional Review Board approval and written informed consent, 30 adult patients were randomly allocated to one of two groups (the PLMA or I-gel group). In each case, insertion time and number of attempts were recorded. After successful insertion, airway leak pressure was measured. RESULTS: Successful insertion and mechanical ventilation with both supraglottic airway devices was achieved on the first attempt in all 30 patients, and there were no significant differences with respect to insertion time. Likewise, leak pressure did not vary significantly either between or within groups after CO(2) insufflation. In addition, differences between leak volume and leak fraction between groups were not significant. CONCLUSIONS: The results of our study indicate that the I-gel is a reasonable alternative to the PLMA for controlled ventilation during laparoscopic gynecologic surgery.

14.
Korean J Anesthesiol ; 61(3): 220-4, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22025944

RESUMO

BACKGROUND: This study examined whether changing the head position from neutral to side can affect expiratory tidal volume (TV) and cuff pressure when the appropriate sizes of a Proseal™ Laryngeal Mask Airway (PLMA)-depending on the body weight -are used in pediatric patients during pressure controlled ventilation (PCV). METHODS: Seventy-seven children (5-30 kg) were divided into three groups according to their body weight, PLMA#1.5 (group I, n = 24), #2 (group II, n = 26), and #2.5 (group III, n = 27). After anesthesia induction, a PLMA was placed with a cuff-pressure of 60 cmH(2)O. The TV and existence of leakage at the peak inspiratory pressure (PIP) of 20 cmH(2)O, and the appropriate PIP for TV 10 ml/kg were examined. Upon head rotation to the left side, the TV, PIP, cuff pressure changes, and the appropriate PIP to achieve a TV 10 ml/kg were evaluated. RESULTS: Head rotation of 45 degrees to the left side during PCV caused a significant increase in cuff pressure and a decrease in TV, and there was no definite leakage. Changes in PIP and TV were similar in the three groups. The cuff pressure increased but there was no significant difference between the three groups. CONCLUSIONS: Although cuff pressure and TV of the PLMA were changed significantly after turning the head from the neutral position to the side, a re-adjustment of the cuff pressure and PIP to maintain a TV of 10 ml/kg can make the placed PLMA useful and successful in pediatric patients under general anesthesia.

15.
Indian J Anaesth ; 54(6): 541-5, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21224972

RESUMO

The laryngeal mask airway (LMA) is a supraglottic airway management device. The LMA is preferred for airway management in paediatric patients for short duration surgical procedures. The recently introduced ProSeal (PLMA), a modification of Classic LMA, has a gastric drainage tube placed lateral to main airway tube which allows the regurgitated gastric contents to bypass the glottis and prevents the pulmonary aspiration. This study was done to compare the efficacy of ProSeal LMA with an endotracheal tube in paediatric patients with respect to number of attempts for placement of devices, haemodynamic responses and perioperative respiratory complications. Sixty children, ASA I and II, weighing 10-20 kg between 2 and 8 years of age group of either sex undergoing elective ophthalmological and lower abdominal surgeries of 30-60 min duration, randomly divided into two groups of 30 patients each were studied. The number of attempts for endotracheal intubation was less than the placement of PLMA. Haemodynamic responses were significantly higher (P<0.05) after endotracheal intubation as compared to the placement of PLMA. There were no significant differences in mean SpO(2) (%) and EtCO(2) levels recorded at different time intervals between the two groups. The incidence of post-operative respiratory complications cough and bronchospasm was higher after extubation than after removal of PLMA. The incidence of soft tissue trauma was noted to be higher for PLMA after its removal. There were no incidences of aspiration and hoarseness/sore throat in either group. It is concluded that ProSeal LMA can be safely considered as a suitable and effective alternative to endotracheal intubation in paediatric patients for short duration surgical procedures.

16.
Korean J Anesthesiol ; 58(5): 450-7, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20532053

RESUMO

BACKGROUND: The aim of this study was to compare the streamlined liner of the pharynx airway (SLIPA), a new supraglottic airway device (SGA), with the laryngeal mask airway ProSeal (PLMA) during general anesthesia. METHODS: Sixty patients were randomly allocated to two groups; a PLMA group (n = 30) or a SLIPA group (n = 30). Ease of use, first insertion success rate, hemodynamic responses to insertion, ventilatory efficiency and positioning confirmed by fiberoptic bronchoscopy were assessed. Lung mechanics data were collected with side stream spirometry at 10 minutes after insertion. We also compared the incidence of blood stain, incidence and severity of postoperative sore throat and other complications. RESULTS: First attempt success rates were 93.3% and 73.3%, and mean insertion time was 7.3 sec and 10.5 sec in PLMA and SLIPA. There was a significant rise in all of hemodynamic response from the pre-insertion value at one minute following insertion of SLIPA. But, insertion of PLMA was no significant rise in hemodynamic response. There was no statistically significant difference in the mean maximum sealing pressure, gas leakage, lung mechanics data, gastric distension, postoperative sore throat and other complication between the two groups. Blood stain were noted on the surface of the device in 40% (n = 12) in the SLIPA vs. 6.7% (n = 2) in the PLMA. CONCLUSIONS: The SLIPA is a useful alternative to the PLMA and have comparable efficacy and complication rates. If we acquire the skill to use, SLIPA may be considered as primary SGA devices during surgery under general anesthesia.

17.
Indian J Anaesth ; 54(2): 109-15, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20661347

RESUMO

ProSeal(TM) Laryngeal Mask Airway (PLMA) for children had been introduced in 2004, by Dr. Archie Brain. It has, in addition to Classic Laryngeal Mask Airway (CLMA), a drainage tube for providing a bypass channel for gastric contents to prevent regurgitation and pulmonary aspiration. A randomized prospective study was performed comprising of 60 ASA - I/II patients, between the age groups of 3 and 10 years, of either sex. All the patients were premedicated with oral Midazolam and Glycopyrollate. General anaesthesia with caudal epidural analgesia was given in all the cases. Inhalation with 8% Sevoflurane was used as a sole induction agent in all the patients. They were randomly divided into two groups. PLMA was inserted in patients of Group P and Endotracheal Tube (ETT) in patients of Group I. In all cases, after PLMA / ETT insertion; caudal epidural analgesia was given and general anaesthesia (GA) using Sevoflurane was provided for maintenance of anaesthesia. Muscle relaxant was not used in our study. We studied parameters such as number of attempts, ease of insertion and conditions during insertion, haemodynamic parameters, changes in SpO(2), EtCO(2), gastric insufflation, regurgitation, pulmonary aspiration, postoperative airway complications and so on. We found that insertion of PLMA as well as ETT was performed in the first attempt in all the patients. Ease of insertion and conditions during insertion were comparable in both the groups. Changes in SpO(2) and EtCO(2) were comparable. However, highly significant changes in haemodynamic parameters were observed in the ETT group. Complications such as sore throat (13.33% cases), coughing (40% cases), vomiting (3.33% cases) and hypoxia (3.33% cases) were observed in the ETT group. No gastric insufflation or regurgitation was noted in our study. Thus, we concluded that PLMA could be used as an effective and safe airway device in children compared to ETT undergoing general anaesthesia.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA