Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Artif Organs ; 47(5): 817-827, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36495089

RESUMO

BACKGROUND: In the total artificial heart (TAH), the inputs to the physiological control unit, preload, and afterload, are detected from intrinsic pump parameters (e.g., motor current). Within this study, their detection techniques are developed, and their reliability in pre- and afterload prediction is mapped for a broad range of cardiovascular system states. METHODS: We used ReinHeart TAH which is a fully implantable TAH with a plunger coil drive that is alternately emptying the left and right chambers. From the coil currents we first derived a force generated by the piston with respect to its position and then analyzed its pattern to detect (1) preload-chamber filling, found as piston position at begin ejection and (2) afterload-mean outflow pressures, determined as linearly calibrated average piston force during ejection. TAH is then integrated into a mock loop circulation (MLC) which is set to 135 different steady operating points varying in chamber filling (0%-100%, five steps), mean outflow pressures (system circulation: 60-90-120 mm Hg, pulmonary circulation: 15-30-45 mm Hg), and heart cycle duration (171-600 ms in seven non-equidistant steps). The detected preload and afterload are compared to MLC set values, and the errors are mapped. RESULTS: Respectively for the left and right chambers, the preload was detectable in 134 and 118 operating points and the mean error was ±3% and ±2%. The afterload was detectable in 135 and 87 operating points and the mean error was 37% and 30% respectively for left and right circulation. The operational points that are further away from homeostatic equilibrium values generally yielded larger errors. The largest errors were observed for right circulation at long cycle duration, low afterload, and low filling. CONCLUSIONS: The study yields reliable preload estimation in a broad range of physiological states, particularly for left circulation. Detection of afterload needs further improvements. The study revealed a need for piston movement optimization within the ReinHeart TAH during the early phase of systole.


Assuntos
Coração Artificial , Coração , Reprodutibilidade dos Testes , Sístole , Circulação Pulmonar
2.
Brain Behav Immun ; 103: 205-214, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35470014

RESUMO

The immune system, which evolved as a protective system, can paradoxically mediate lethal effects when it is over-activated. These effects can be traced back to infected insects and are mainly mediated by phylogenetically old cytokines that have been found already in starfishes and sponges. We hypothesize that these anti-homeostatic effects are important for restricting the cumulative risk of transmission of highly mutating environmental pathogens that may endanger species, particularly when they start to originate and expand. Considering the Darwinian view that evolution is a permanent process, this anti-homeostatic program is preserved and expressed even when there is no risk for the species. Here, we review these aspects and discuss how evolutionary-imposed anti-homeostatic immune programs are expressed during acute and chronic human diseases, which can be further aggravated in the absence of medical interventions. The relevance of early identification of ancestral biomarkers that predict a shift from protective to deleterious immune outcomes is emphasized.


Assuntos
Citocinas , Doença Crônica , Homeostase , Humanos
3.
Artif Organs ; 46(1): 71-82, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34287976

RESUMO

The objective of this study is to identify the preload and afterload sensitivity of the ReinHeart TAH 2.0. For adequate left-right flow balance, the concept of a reduced right stroke volume (by about 10%) and active adaption of the right diastole duration are evaluated concerning the controllability of the flow balance. This study used an active mock circulation loop to test a wide range of preload and afterload conditions. Preload sensitivity was tested at atrial pressures (APs) between 4 and 20 mm Hg. Left afterload was varied in a range of 60-140 mm Hg mean aortic pressure (MAP), right afterload was simulated between 15 and 40 mm Hg. Four scenarios were developed to verify that the flow difference fully covers the defined target range of 0-1.5 L/min. Although a positive correlation between inlet pressure and flow is identified for the right pump chamber, the left pump chamber already fills completely at an inlet pressure of 8-10 mm Hg. With increasing afterload, both the left and right flow decrease. A positive flow balance (left flow exceeds right flow) is achieved over the full range of tested afterloads. At high APs, the flow difference is limited to a maximum of 0.7 L/min. The controllability of flow balance was successfully evaluated in four scenarios, revealing that a positive flow difference can be achieved over the full range of MAPs. Under physiological test conditions, the linear relationship between flow and heart rate was confirmed, ensuring good controllability of the TAH.


Assuntos
Circulação Sanguínea , Coração Artificial , Desenho de Prótese , Pressão Sanguínea , Frequência Cardíaca , Hidrodinâmica , Modelos Cardiovasculares
4.
J Exp Biol ; 224(16)2021 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-34387318

RESUMO

Evolutionary physiology strives to understand how the function and integration of physiological systems influence the way in which organisms evolve. Studies of the O2 transport pathway - the integrated physiological system that transports O2 from the environment to mitochondria - are well suited to this endeavour. We consider the mechanistic underpinnings across the O2 pathway for the evolution of aerobic capacity, focusing on studies of artificial selection and naturally selected divergence among wild populations of mammals and fish. We show that evolved changes in aerobic capacity do not require concerted changes across the O2 pathway and can arise quickly from changes in one or a subset of pathway steps. Population divergence in aerobic capacity can be associated with the evolution of plasticity in response to environmental variation or activity. In some cases, initial evolutionary divergence of aerobic capacity arose exclusively from increased capacities for O2 diffusion and/or utilization in active O2-consuming tissues (muscle), which may often constitute first steps in adaptation. However, continued selection leading to greater divergence in aerobic capacity is often associated with increased capacities for circulatory and pulmonary O2 transport. Increases in tissue O2 diffusing capacity may augment the adaptive benefit of increasing circulatory O2 transport owing to their interactive influence on tissue O2 extraction. Theoretical modelling of the O2 pathway suggests that O2 pathway steps with a disproportionately large influence over aerobic capacity have been more likely to evolve, but more work is needed to appreciate the extent to which such physiological principles can predict evolutionary outcomes.


Assuntos
Aclimatação , Altitude , Adaptação Fisiológica , Animais , Mamíferos , Consumo de Oxigênio , Fenótipo
5.
Artif Organs ; 45(4): 364-372, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33001469

RESUMO

A total artificial heart (TAH) must be designed to autonomously balance the flows of the systemic and pulmonary circulation to prevent potentially lethal lung damage. The flow difference between the systemic and pulmonary circulation is mainly caused by the bronchial (arteries) shunt flow and can change dynamically. The ReinHeart TAH consists of only one actuator that ejects blood alternately from the right and left pump chamber. This design entails a coupling of the right and left stroke and thus, complicates the independent adaptation of the right and left flow. In this experimental study on the ReinHeart TAH, four concepts to keep the flows well balanced were investigated using an active mock circulation loop for data acquisition. Three concepts are based on mechanical design changes (variation of pusher plate shape, flexible right pump chamber housing, and reduced right stroke volume) to achieve a static flow difference. In combination with these static concepts, a concept influencing the ratio of systole and diastole duration to respond to dynamic changes was studied. In total, four measurement series, each with 270 operating points, to investigate the influence of circulatory filling volume, heart rate, bronchial shunt flow, and lung resistance were recorded. In the course of this study, we introduce a concept deviation indicator, providing information about the efficiency of the concepts to balance the flows based on changes in lung's blood pressures. Furthermore, the distribution of the measured data was evaluated based on bubble plot visualizations. The investigated variation of the right pusher plate shape results in high lung pressures which will cause lethal lung damage. In comparison, a flexible right pump chamber housing shows lower lung pressures, but it still has the potential to damage the lungs. Reducing the stroke volume of the right pump chamber results in proper lung pressures. The flow balance can dynamically be influenced with a positive effect on the lung pressures by choosing a suitable systole-diastole-ratio. The results of this study suggest that an adequate right-left flow balance can be achieved by combining the mechanical concept of a reduced right stroke volume with an active control of the systole-diastole-ratio.


Assuntos
Coração Artificial , Modelos Cardiovasculares , Desenho de Prótese , Circulação Pulmonar/fisiologia , Pressão Sanguínea/fisiologia , Artérias Brônquicas/fisiologia , Diástole/fisiologia , Frequência Cardíaca/fisiologia , Humanos , Volume Sistólico/fisiologia , Sístole/fisiologia
6.
Artigo em Inglês | MEDLINE | ID: mdl-34298193

RESUMO

We examine here the effects on evaporative water loss, at and below thermoneutrality, of perturbing the evaporative environment for the red-capped parrot (Purpureicephalus spurius) by modifying the ambient relative humidity or the diffusive properties of the ambient environment using a helium­oxygen mix (helox). We found that evaporative water loss did not change with relative humidity at an ambient temperature of 30 °C, but there was a negative relationship for evaporative water loss with relative humidity at 20 and 25 °C. The evaporative water loss per water vapour pressure deficit between the bird and its ambient environment was not constant with relative humidity, as would be expected for a physical effect (slope = 0); rather there was a significant positive relationship with relative humidity at ambient temperatures of 25 and 30 °C. Consequently, we conclude that the red-capped parrot can physiologically control its EWL over a range of relative humidities. For the first time for a bird species, we also confirmed EWL control using a second methodology to perturb the evaporative environment, and demonstrated that a more diffusive helox atmosphere has no effect on evaporative water loss of live birds, but evaporative water loss was higher for dead birds in helox compared to air. Our results for evaporative water loss and other physiological variables for red-capped parrots are consistent with the hypothesis that evaporative water loss is under physiological control.


Assuntos
Regulação da Temperatura Corporal/fisiologia , Papagaios/fisiologia , Perda Insensível de Água/fisiologia , Animais , Feminino , Umidade , Masculino , Condutividade Térmica
7.
J Exp Biol ; 223(Pt 19)2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32747451

RESUMO

Insensible evaporative water loss (EWL) at or below thermoneutrality is generally assumed to be a passive physical process. However, some arid zone mammals and a single arid zone bird can control their insensible water loss, so we tested the hypothesis that the same is the case for two parrot species from a mesic habitat. We investigated red-rumped parrots (Psephotus haematonotus) and eastern rosellas (Platycercus eximius), measuring their EWL, and other physiological variables, at a range of relative humidities at ambient temperatures of 20 and 30°C (below and at thermoneutrality). We found that, despite a decrease in EWL with increasing relative humidity, rates of EWL were not fully accounted for by the water vapour deficit between the animal and its environment, indicating that the insensible EWL of both parrots was controlled. It is unlikely that this deviation from physical expectations was regulation with a primary role for water conservation because our mesic-habitat parrots had equivalent regulatory ability as the arid habitat budgerigar (Melopsittacus undulatus). This, together with our observations of body temperature and metabolic rate, instead support the hypothesis that acute physiological control of insensible water loss serves a thermoregulatory purpose for endotherms. Modification of both cutaneous and respiratory avenues of evaporation may be involved, possibly via modification of expired air temperature and humidity, and surface resistance.


Assuntos
Papagaios , Perda Insensível de Água , Animais , Regulação da Temperatura Corporal , Temperatura , Água
8.
Crit Care ; 24(1): 121, 2020 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-32223754

RESUMO

The level of automation in mechanical ventilation has been steadily increasing over the last few decades. There has recently been renewed interest in physiological closed-loop control of ventilation. The development of these systems has followed a similar path to that of manual clinical ventilation, starting with ensuring optimal gas exchange and shifting to the prevention of ventilator-induced lung injury. Systems currently aim to encompass both aspects, and early commercial systems are appearing. These developments remain unknown to many clinicians and, hence, limit their adoption into the clinical environment. This review shows the evolution of the physiological closed-loop control of mechanical ventilation.

9.
Artif Organs ; 44(8): 785-796, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31944337

RESUMO

Left ventricular assist devices (LVADs) have been used as a bridge to transplantation or as destination therapy to treat patients with heart failure (HF). The inability of control strategy to respond automatically to changes in hemodynamic conditions can impact the patients' quality of life. The developed control system/algorithm consists of a control system that harmoniously adjusts pump speed without additional sensors, considering the patient's clinical condition and his physical activity. The control system consists of three layers: (a) Actuator speed control; (b) LVAD flow control (FwC); and (c) Fuzzy control system (FzC), with the input variables: heart rate (HR), mean arterial pressure (MAP), minimum pump flow, level of physical activity (data from patient), and clinical condition (data from physician, INTERMACS profile). FzC output is the set point for the second LVAD control schemer (FwC) which in turn adjusts the speed. Pump flow, MAP, and HR are estimated from actuator drive parameters (speed and power). Evaluation of control was performed using a centrifugal blood pump in a hybrid cardiovascular simulator, where the left heart function is the mechanical model and right heart function is the computational model. The control system was able to maintain MAP and cardiac output in the physiological level, even under variation of EF. Apart from this, also the rotational pump speed is adjusted following the simulated clinical condition. No backflow from the aorta in the ventricle occurred through LVAD during tests. The control algorithm results were considered satisfactory for simulations, but it still should be confirmed during in vivo tests.


Assuntos
Coração Auxiliar , Hemodinâmica/fisiologia , Pressão Arterial , Exercício Físico/fisiologia , Lógica Fuzzy , Frequência Cardíaca/fisiologia , Humanos , Modelos Biológicos , Desenho de Prótese
10.
Artif Organs ; 44(3): E40-E53, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31520408

RESUMO

Due to improved durability and survival rates, rotary blood pumps (RBPs) are the preferred left ventricular assist device when compared to volume displacement pumps. However, when operated at constant speed, RBPs lack a volume balancing mechanism which may result in left ventricular suction and suboptimal ventricular unloading. Starling-like controllers have previously been developed to balance circulatory volumes; however, they do not consider ventricular workload as a feedback and may have limited sensitivity to adjust RBP workload when ventricular function deteriorates or improves. To address this, we aimed to develop a Starling-like total work controller (SL-TWC) that matched the energy output of a healthy heart by adjusting RBP hydraulic work based on measured left ventricular stroke work and ventricular preload. In a mock circulatory loop, the SL-TWC was evaluated using a HeartWare HVAD in a range of simulated patient conditions. These conditions included changes in systemic hypertension and hypotension, pulmonary hypertension, blood circulatory volume, exercise, and improvement and deterioration of ventricular function by increasing and decreasing ventricular contractility. The SL-TWC was compared to constant speed control where RBP speed was set to restore cardiac output to 5.0 L/min at rest. Left ventricular suction occurred with constant speed control during pulmonary hypertension but was prevented with the SL-TWC. During simulated exercise, the SL-TWC demonstrated reduced LVSW (0.51 J) and greater RBP flow (9.2 L/min) compared to constant speed control (LVSW: 0.74 J and RBP flow: 6.4 L/min). In instances of increased ventricular contractility, the SL-TWC reduced RBP hydraulic work while maintaining cardiac output similar to the rest condition. In comparison, constant speed overworked and increased cardiac output. The SL-TWC balanced circulatory volumes by mimicking the Starling mechanism, while also considering changes in ventricular workload. Compared to constant speed control, the SL-TWC may reduce complications associated with volume imbalances, adapt to changes in ventricular function and improve patient quality of life.


Assuntos
Simulação por Computador , Coração Auxiliar , Modelos Cardiovasculares , Função Ventricular Esquerda , Desenho de Equipamento , Exercício Físico , Hemodinâmica , Humanos
11.
Artif Organs ; 43(3): E16-E27, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30094842

RESUMO

Rotary ventricular assist devices (VADs) are less sensitive to preload than the healthy heart, resulting in inadequate flow regulation in response to changes in patient cardiac demand. Starling-like physiological controllers (SLCs) have been developed to automatically regulate VAD flow based on ventricular preload. An SLC consists of a cardiac response curve (CRC) which imposes a nonlinear relationship between VAD flow and ventricular preload, and a venous return line (VRL) which determines the return path of the controller. This study investigates the importance of a physiological VRL in SLC of dual rotary blood pumps for biventricular support. Two experiments were conducted on a physical mock circulation loop (MCL); the first compared an SLC with an angled physiological VRL (SLC-P) against an SLC with a vertical VRL (SLC-V). The second experiment quantified the benefit of a dynamic VRL, represented by a series of specific VRLs, which could adapt to different circulatory states including changes in pulmonary (PVR) and systemic (SVR) vascular resistance versus a fixed physiological VRL which was calculated at rest. In both sets of experiments, the transient controller responses were evaluated through reductions in preload caused by the removal of fluid from the MCL. The SLC-P produced no overshoot or oscillations following step changes in preload, whereas SLC-V produced 0.4 L/min (12.5%) overshoot for both left and right VADs. Additionally, the SLC-V had increased settling time and reduced controller stability as evidenced by transient controller oscillations. The transient results comparing the specific and standard VRLs demonstrated that specific VRL rise times were improved by between 1.2 and 4.7 s ( x ¯ = 3.05 s), while specific VRL settling times were improved by between 2.8 and 16.1 seconds ( x ¯ = 8.38 s) over the standard VRL. This suggests only a minor improvement in controller response time from a dynamic VRL compared to the fixed VRL. These results indicate that the use of a fixed physiologically representative VRL is adequate over a wide variety of physiological conditions.


Assuntos
Circulação Sanguínea/fisiologia , Desenho de Equipamento , Coração Auxiliar , Débito Cardíaco/fisiologia , Simulação por Computador , Humanos , Fatores de Tempo , Veias/fisiologia
12.
Artif Organs ; 43(11): E294-E307, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31188476

RESUMO

Rotary ventricular assist devices (VADs) operated clinically under constant speed control (CSC) cannot respond adequately to changes in patient cardiac demand, resulting in sub-optimal VAD flow regulation. Starling-like control (SLC) of VADs mimics the healthy ventricular flow regulation and automatically adjusts VAD speed to meet varying patient cardiac demand. The use of a fixed control line (CL - the relationship between ventricular preload and VAD flow) limits the flow regulating capability of the controller, especially in the case of exercise. Adaptive SLC (ASLC) overcomes this limitation by allowing the controller to adapt the CL to meet a diverse range of circulatory conditions. This study evaluated ASLC, SLC and CSC in a biventricular supported mock circulation loop under the simulated conditions of exercise, sleep, fluid loading and systemic hypertension. Each controller was evaluated on its ability to remain within predefined limits of VAD flow, preload, and afterload. The ASLC produced superior cardiac output (CO) during exercise (10.1 L/min) compared to SLC (7.3 L/min) and CSC (6.3 L/min). The ASLC produced favourable haemodynamics during sleep, fluid loading and systemic hypertension and could remain within a predefined haemodynamic range in three out of four simulations, suggesting improved haemodynamic performance over SLC and CSC.


Assuntos
Coração Auxiliar , Hemodinâmica , Débito Cardíaco , Simulação por Computador , Exercício Físico , Humanos , Modelos Cardiovasculares , Sono
13.
Artif Organs ; 41(10): E118-E128, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28621838

RESUMO

Rotary blood pumps (RBPs) are used for mechanical circulatory support in heart failure patients but exhibit a reduced response to preload changes, which can lead to ventricular suction events. A passive control system, in the form of a compliant inflow cannula (IC), has been developed to mitigate suction, although this device may cause significant hemolysis. This study compared the incidence of mechanically induced hemolysis of two compliant IC designs (strutted and nonstrutted) with a rigid IC (control) in a blood circulation loop over 90 min. The nonstrutted compliant IC introduced high frequency and high amplitude oscillations in RBP inlet pressure and RBP IC resistance. These oscillations were correlated with a significant increase in plasma-free hemoglobin (pfHb) and hemolysis: pfHb increased to 2.005 ± 0.665 g/L, while normalized index of hemolysis (NIH) and modified index of hemolysis (MIH) increased to 0.04945 ± 0.01276 g/100 L and 4.0505 ± 0.6589 after 90 min (P < 0.05). In contrast, the strutted compliant IC performed similar to the clinically utilized rigid IC and did not increase pfHb (0.300 ± 0.090 and 0.320 ± 0.171 g/L, respectively) and rate of hemolysis (NIH 0.00435 ± 0.00155 and 0.00543 ± 0.00371 g/100 L; MIH 0.3896 ± 0.1749 and 0.4261 ± 0.2792, respectively) within the RBP circuit. These data indicated that strutted, compliant ICs meet the hemocompatibility of clinically used rigid ICs while also offering a potential solution to prevent ventricular suction events.


Assuntos
Cânula/efeitos adversos , Coração Auxiliar/efeitos adversos , Hemólise , Adulto , Desenho de Equipamento , Contagem de Eritrócitos , Eritrócitos/citologia , Eritrócitos/patologia , Insuficiência Cardíaca/terapia , Hemodinâmica , Humanos , Teste de Materiais , Modelos Cardiovasculares
14.
Artif Organs ; 41(10): 911-922, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28741664

RESUMO

Rotary ventricular assist devices (VADs) are used to provide mechanical circulatory support. However, their lack of preload sensitivity in constant speed control mode (CSC) may result in ventricular suction or venous congestion. This is particularly true of biventricular support, where the native flow-balancing Starling response of both ventricles is diminished. It is possible to model the Starling response of the ventricles using cardiac output and venous return curves. With this model, we can create a Starling-like physiological controller (SLC) for VADs which can automatically balance cardiac output in the presence of perturbations to the circulation. The comparison between CSC and SLC of dual HeartWare HVADs using a mock circulation loop to simulate biventricular heart failure has been reported. Four changes in cardiovascular state were simulated to test the controller, including a 700 mL reduction in circulating fluid volume, a total loss of left and right ventricular contractility, reduction in systemic vascular resistance ( SVR) from 1300 to 600 dyne  s/cm5, and an elevation in pulmonary vascular resistance ( PVR) from 100 to 300 dyne  s/cm5. SLC maintained the left and right ventricular volumes between 69-214 mL and 29-182 mL, respectively, for all tests, preventing ventricular suction (ventricular volume = 0 mL) and venous congestion (atrial pressures > 20 mm Hg). Cardiac output was maintained at sufficient levels by the SLC, with systemic and pulmonary flow rates maintained above 3.14 L/min for all tests. With the CSC, left ventricular suction occurred during reductions in SVR, elevations in PVR, and reduction in circulating fluid simulations. These results demonstrate a need for a physiological control system and provide adequate in vitro validation of the immediate response of a SLC for biventricular support.


Assuntos
Simulação por Computador , Coração Auxiliar , Hemodinâmica , Modelos Cardiovasculares , Volume Sanguíneo , Débito Cardíaco , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Coração Auxiliar/efeitos adversos , Humanos , Desenho de Prótese , Resistência Vascular
15.
Artif Organs ; 40(9): 842-55, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27645395

RESUMO

The current article presents a novel physiological feedback controller for turbodynamic ventricular assist devices (tVADs). This controller is based on the recording of the left ventricular (LV) pressure measured at the inlet cannula of a tVAD thus requiring only one pressure sensor. The LV systolic pressure (SP) is proposed as an indicator to determine the varying perfusion requirements. The algorithm to extract the SP from the pump inlet pressure signal used for the controller to adjust the speed of the tVAD shows robust behavior. Its performance was evaluated on a hybrid mock circulation. The experiments with changing perfusion requirements were compared with a physiological circulation and a pathological one assisted with a tVAD operated at constant speed. A sensitivity analysis of the controller parameters was conducted to identify their limits and their influence on a circulation. The performance of the proposed SP controller was evaluated for various values of LV contractility, as well as for a simulated pressure sensor drift. The response of a pathological circulation assisted by a tVAD controlled by the introduced SP controller matched the physiological circulation well, while over- and underpumping events were eliminated. The controller presented a robust performance during experiments with simulated pressure sensor drift.


Assuntos
Coração Auxiliar , Pressão Ventricular , Pressão Sanguínea , Desenho de Equipamento , Humanos , Modelos Cardiovasculares , Fluxo Pulsátil
16.
Artif Organs ; 40(9): 894-903, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26748566

RESUMO

Preventing ventricular suction and venous congestion through balancing flow rates and circulatory volumes with dual rotary ventricular assist devices (VADs) configured for biventricular support is clinically challenging due to their low preload and high afterload sensitivities relative to the natural heart. This study presents the in vivo evaluation of several physiological control systems, which aim to prevent ventricular suction and venous congestion. The control systems included a sensor-based, master/slave (MS) controller that altered left and right VAD speed based on pressure and flow; a sensor-less compliant inflow cannula (IC), which altered inlet resistance and, therefore, pump flow based on preload; a sensor-less compliant outflow cannula (OC) on the right VAD, which altered outlet resistance and thus pump flow based on afterload; and a combined controller, which incorporated the MS controller, compliant IC, and compliant OC. Each control system was evaluated in vivo under step increases in systemic (SVR ∼1400-2400 dyne/s/cm(5) ) and pulmonary (PVR ∼200-1000 dyne/s/cm(5) ) vascular resistances in four sheep supported by dual rotary VADs in a biventricular assist configuration. Constant speed support was also evaluated for comparison and resulted in suction events during all resistance increases and pulmonary congestion during SVR increases. The MS controller reduced suction events and prevented congestion through an initial sharp reduction in pump flow followed by a gradual return to baseline (5.0 L/min). The compliant IC prevented suction events; however, reduced pump flows and pulmonary congestion were noted during the SVR increase. The compliant OC maintained pump flow close to baseline (5.0 L/min) and prevented suction and congestion during PVR increases. The combined controller responded similarly to the MS controller to prevent suction and congestion events in all cases while providing a backup system in the event of single controller failure.


Assuntos
Insuficiência Cardíaca/terapia , Ventrículos do Coração/cirurgia , Coração Auxiliar , Animais , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/fisiopatologia , Hemodinâmica , Modelos Cardiovasculares , Circulação Pulmonar , Ovinos , Resistência Vascular , Função Ventricular Esquerda , Função Ventricular Direita
17.
Artif Organs ; 40(7): 638-44, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26634983

RESUMO

A physiological control algorithm is being developed to ensure an optimal physiological interaction between the ReinHeart total artificial heart (TAH) and the circulatory system. A key factor for that is the long-term, accurate determination of the hemodynamic state of the cardiovascular system. This study presents a method to determine estimation models for predicting hemodynamic parameters (pump chamber filling and afterload) from both left and right cardiovascular circulations. The estimation models are based on linear regression models that correlate filling and afterload values with pump intrinsic parameters derived from measured values of motor current and piston position. Predictions for filling lie in average within 5% from actual values, predictions for systemic afterload (AoPmean , AoPsys ) and mean pulmonary afterload (PAPmean ) lie in average within 9% from actual values. Predictions for systolic pulmonary afterload (PAPsys ) present an average deviation of 14%. The estimation models show satisfactory prediction and confidence intervals and are thus suitable to estimate hemodynamic parameters. This method and derived estimation models are a valuable alternative to implanted sensors and are an essential step for the development of a physiological control algorithm for a fully implantable TAH.


Assuntos
Coração Artificial , Hemodinâmica , Algoritmos , Aorta/fisiologia , Pressão Arterial , Desenho de Equipamento , Humanos , Modelos Cardiovasculares , Fluxo Pulsátil
18.
Artif Organs ; 39(2): 102-9, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25041754

RESUMO

Biventricular support with dual rotary ventricular assist devices (VADs) has been implemented clinically with restriction of the right VAD (RVAD) outflow cannula to artificially increase afterload and, therefore, operate within recommended design speed ranges. However, the low preload and high afterload sensitivity of these devices increase the susceptibility of suction events. Active control systems are prone to sensor drift or inaccurate inferred (sensor-less) data, therefore an alternative solution may be of benefit. This study presents the in vitro evaluation of a compliant outflow cannula designed to passively decrease the afterload sensitivity of rotary RVADs and minimize left-sided suction events. A one-way fluid-structure interaction model was initially used to produce a design with suitable flow dynamics and radial deformation. The resultant geometry was cast with different initial cross-sectional restrictions and concentrations of a softening diluent before evaluation in a mock circulation loop. Pulmonary vascular resistance (PVR) was increased from 50 dyne s/cm(5) until left-sided suction events occurred with each compliant cannula and a rigid, 4.5 mm diameter outflow cannula for comparison. Early suction events (PVR ∼ 300 dyne s/cm(5) ) were observed with the rigid outflow cannula. Addition of the compliant section with an initial 3 mm diameter restriction and 10% diluent expanded the outflow restriction as PVR increased, thus increasing RVAD flow rate and preventing left-sided suction events at PVR levels beyond 1000 dyne s/cm(5) . Therefore, the compliant, restricted outflow cannula provided a passive control system to assist in the prevention of suction events with rotary biventricular support while maintaining pump speeds within normal ranges of operation.


Assuntos
Catéteres , Coração Auxiliar , Desenho de Equipamento , Hemodinâmica , Humanos , Modelos Cardiovasculares , Sucção
19.
Artif Organs ; 38(9): 766-74, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24749848

RESUMO

Dual rotary left ventricular assist devices (LVADs) can provide biventricular mechanical support during heart failure. Coordination of left and right pump speeds is critical not only to avoid ventricular suction and to match cardiac output with demand, but also to ensure balanced systemic and pulmonary circulatory volumes. Physiological control systems for dual LVADs must meet these objectives across a variety of clinical scenarios by automatically adjusting left and right pump speeds to avoid catastrophic physiological consequences. In this study we evaluate a novel master/slave physiological control system for dual LVADs. The master controller is a Starling-like controller, which sets flow rate as a function of end-diastolic ventricular pressure (EDP). The slave controller then maintains a linear relationship between right and left EDPs. Both left/right and right/left master/slave combinations were evaluated by subjecting them to four clinical scenarios (rest, postural change, Valsalva maneuver, and exercise) simulated in a mock circulation loop. The controller's performance was compared to constant-rotational-speed control and two other dual LVAD control systems: dual constant inlet pressure and dual Frank-Starling control. The results showed that the master/slave physiological control system produced fewer suction events than constant-speed control (6 vs. 62 over a 7-min period). Left/right master/slave control had lower risk of pulmonary congestion than the other control systems, as indicated by lower maximum EDPs (15.1 vs. 25.2-28.4 mm Hg). During exercise, master/slave control increased total flow from 5.2 to 10.1 L/min, primarily due to an increase of left and right pump speed. Use of the left pump as the master resulted in fewer suction events and lower EDPs than when the right pump was master. Based on these results, master/slave control using the left pump as the master automatically adjusts pump speed to avoid suction and increases pump flow during exercise without causing pulmonary venous congestion.


Assuntos
Coração Auxiliar , Função Ventricular Esquerda , Pressão Ventricular , Simulação por Computador , Desenho de Equipamento , Coração Auxiliar/efeitos adversos , Humanos , Modelos Cardiovasculares , Fluxo Pulsátil , Função Ventricular Direita
20.
Artif Organs ; 38(7): 527-38, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24256168

RESUMO

The current article presents a novel physiological control algorithm for ventricular assist devices (VADs), which is inspired by the preload recruitable stroke work. This controller adapts the hydraulic power output of the VAD to the end-diastolic volume of the left ventricle. We tested this controller on a hybrid mock circulation where the left ventricular volume (LVV) is known, i.e., the problem of measuring the LVV is not addressed in the current article. Experiments were conducted to compare the response of the controller with the physiological and with the pathological circulation, with and without VAD support. A sensitivity analysis was performed to analyze the influence of the controller parameters and the influence of the quality of the LVV signal on the performance of the control algorithm. The results show that the controller induces a response similar to the physiological circulation and effectively prevents over- and underpumping, i.e., ventricular suction and backflow from the aorta to the left ventricle, respectively. The same results are obtained in the case of a disturbed LVV signal. The results presented in the current article motivate the development of a robust, long-term stable sensor to measure the LVV.


Assuntos
Coração Auxiliar , Função Ventricular Esquerda , Algoritmos , Circulação Sanguínea , Ventrículos do Coração/fisiopatologia , Humanos , Modelos Cardiovasculares , Desenho de Prótese , Fluxo Pulsátil
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA