Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 181
Filtrar
1.
J Surg Res ; 300: 141-149, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38810527

RESUMO

INTRODUCTION: Transversus abdominis release (TAR) is increasingly being performed for reconstruction of complex incisional and recurrent ventral hernias, with complication rates ranging from 17.4% to 33.3% after open TAR (oTAR) or robotic TAR (rTAR). The purpose of this study was to describe the outcomes of patients undergoing TAR with macroporous polypropylene mesh (MPM) and to compare outcomes between oTAR and rTAR. METHODS: A retrospective review of 183 consecutive patients undergoing TAR with MPM performed by a single surgeon at a single institution from 2015 to 2021 was performed. Patients with less than one year of follow-up were excluded. Univariate analysis was performed to compare outcomes between oTAR and rTAR patients. RESULTS: Average patient age was 59.4 y, median body mass index was 33.2 kg/m2, and median hernia width was 12.0 cm. Forty 2 (23%) patients underwent oTAR, 127 (69%) underwent rTAR, and 14 (8%) underwent laparoscopic TAR. Patients experienced 16.4%, 10.4%, 3.8%, and 6.0% rates of overall complications, surgical site occurrences, surgical site infections, and other complications, respectively. At average follow-up of 2.3 y, a 2.7% hernia recurrence rate was observed. In comparison to patients undergoing oTAR, rTAR patients required shorter operative times and length of stay, and were less likely to experience postoperative complications overall, and other complications. Recurrence rates were similar between oTAR and rTAR. CONCLUSIONS: Patients undergoing TAR with MPM experienced complication and recurrence rates in alignment with previously published results. In comparison to oTAR, rTAR was associated with more favorable perioperative outcomes and complication rates, but similar recurrence rates.


Assuntos
Músculos Abdominais , Hérnia Ventral , Herniorrafia , Polipropilenos , Complicações Pós-Operatórias , Telas Cirúrgicas , Humanos , Telas Cirúrgicas/efeitos adversos , Pessoa de Meia-Idade , Estudos Retrospectivos , Masculino , Feminino , Idoso , Hérnia Ventral/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Herniorrafia/instrumentação , Herniorrafia/métodos , Herniorrafia/efeitos adversos , Resultado do Tratamento , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Recidiva , Adulto , Seguimentos , Laparoscopia/efeitos adversos , Laparoscopia/métodos
2.
Surg Endosc ; 38(5): 2871-2878, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38609587

RESUMO

BACKGROUND: The use of mesh is standard of care for large ventral hernias repaired on an elective basis. The most used type of mesh includes synthetic polypropylene mesh; however, there has been an increase in the usage of a new polyester self-gripping mesh, and there are limited data regarding its efficacy for ventral hernia. The purpose of the study is to determine whether there is a difference in surgical site occurrence (SSO), surgical site infection (SSI), surgical site occurrence requiring procedural intervention (SSOPI), and recurrence at 30 days after ventral hernia repair (VHR) using self-gripping (SGM) versus non-self-gripping mesh (NSGM). METHODS: We performed a retrospective study from January 2014 to April 2022 using the Abdominal Core Health Quality Collaborative (ACHQC). We collected data on patients over 18 years of age who underwent elective open VHR using SGM or NSGM and whom had 30-day follow-up. Propensity matching was utilized to control for variables including hernia width, body mass index, age, ASA, and mesh location. Data were analyzed to identify differences in SSO, SSI, SSOPI, and recurrence at 30 days. RESULTS: 9038 patients were identified. After propensity matching, 1766 patients were included in the study population. Patients with SGM had similar demographic and clinical characteristics compared to NSGM. The mean hernia width to mesh width ratio was 8 cm:18 cm with NSGM and 7 cm:15 cm with SGM (p = 0.63). There was no difference in 30-day rates of recurrence, SSI or SSO. The rate of SSOPI was also found to be 5.4% in the nonself-gripping group compared to 3.1% in the self-gripping mesh group (p < .005). There was no difference in patient-reported outcomes at 30 days. CONCLUSIONS: In patients undergoing ventral hernia repair with mesh, self-gripping mesh is a safe type of mesh to use. Use of self-gripping mesh may be associated with lower rates of SSOPI when compared to nonself-gripping mesh.


Assuntos
Hérnia Ventral , Herniorrafia , Recidiva , Telas Cirúrgicas , Humanos , Hérnia Ventral/cirurgia , Estudos Retrospectivos , Masculino , Feminino , Herniorrafia/métodos , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/epidemiologia , Adulto , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
3.
Int Urogynecol J ; 35(3): 553-559, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38206335

RESUMO

INTRODUCTION AND HYPOTHESIS: Polypropylene meshes (PM) used in pelvic organ prolapse surgery are being withdrawn from the market. Although concerns about the usage of PMs in stress incontinence surgery have been raised, it is still one of the best methods of curing stress urinary incontinence. With advancements in stem cell-based therapies, especially mesenchymal stem cells (MSCs), it is believed that coating the synthetic meshes with MSCs may minimize excessive tissue reactions ultimately leading to clinical problems such as pain, erosion or extrusion of the implanted material. In our study we tried to show the possibility of coating the PM with placenta-derived MSCs. METHODS: Mesenchymal stem cells obtained from six placentas were isolated, cultured, and identified. MSCs were then soaked in either fibronectin or collagen prior to co-culturing with strips of PMs. One group is used as a control, and hence was not pretreated before co-culturing. Specimens were fixed and stained with both Gram and hematoxylin and eosin and marked with Vybran Dil and DAPI. All preparations were examined under a light microscope. The IMAGEJ program was utilized to determine the surface area of meshes coated with MSCs. RESULTS: We clearly showed that PMs can be coated successfully with placenta-derived MSCs. The percentage of the coated area is significantly increased when meshes were pretreated with fibronectin or collagen (p<0.0001). CONCLUSIONS: Placenta-derived MSCs can successfully coat PMs. The immunomodulatory properties of MSCs, which may be of great advantage in preventing the side effects of meshes, should be tested by in vivo and hopefully human studies before clinical applications.


Assuntos
Células-Tronco Mesenquimais , Incontinência Urinária por Estresse , Humanos , Polipropilenos , Projetos Piloto , Fibronectinas , Telas Cirúrgicas/efeitos adversos , Colágeno , Incontinência Urinária por Estresse/cirurgia
4.
Aesthetic Plast Surg ; 48(5): 925-935, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37464216

RESUMO

BACKGROUND: Implant-based breast reconstruction (IBBR) can be performed using a variety of biological and synthetic meshes. However, there has yet to be a consensus on the optimal mesh. This study investigates the safety and patient satisfaction of using TiLOOP® Bra in IBBR and compares its postoperative complication risk with that of porcine acellular dermal matrix (ADM) and SERAGYN® BR. METHODS: The literature review was performed via PRISMA criteria, 23 studies met the inclusion criteria for the TiLOOP® Bra review, and 5 studies met the inclusion criteria for the meta-analysis. Patient characteristics and per-breast complications were collected. Data were analyzed using Cochrane RevMan and IBM SPSS. RESULTS: In 3175 breasts of 2685 patients that underwent IBBR using TiLOOP® Bra, rippling was observed as the most common complication, followed by seroma and capsular contracture. No significant difference in the overall complication rate between pre- and sub-pectoral IBBR using TiLOOP® Bra. However, the meta-analysis showed that the TiLOOP® Bra group had significantly lower odds of implant loss, seroma, wound dehiscence, and the need for reoperation or hospitalization than the ADM group. Additionally, the TiLOOP® Bra group had a significantly lower seroma rate compared to the SERAGYN® BR group, while the other outcome indicators were similar between the two groups. CONCLUSION: TiLOOP® Bra has become increasingly popular in IBBR in recent years. This review and meta-analysis support the favorable safety profile of TiLOOP® Bra reported in the current literature. The meta-analysis revealed that TiLOOP® Bra has better safety than ADM and a comparable risk of complications compared to SERAGYN® BR. However, as most studies had low levels of evidence, further investigations are necessary. LEVEL OF EVIDENCE III: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Derme Acelular , Implante Mamário , Implantes de Mama , Neoplasias da Mama , Mamoplastia , Animais , Feminino , Humanos , Neoplasias da Mama/cirurgia , Polipropilenos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Estudos Retrospectivos , Seroma , Telas Cirúrgicas , Suínos , Titânio , Resultado do Tratamento
5.
Medicina (Kaunas) ; 60(9)2024 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-39336589

RESUMO

Background and Objectives: Surgical site infections (SSIs) are a significant complication following ventral hernia repair, potentially leading to prolonged hospital stays and increased morbidity. This study aimed to evaluate whether closed incision negative pressure wound therapy (ciNPWT) reduces the incidence of SSI after ventral hernia repair with polypropylene mesh compared to standard wound care. Materials and Methods: A randomized study was conducted with 100 patients undergoing ventral hernia repair using a polypropylene mesh. Participants were divided into two groups: a control group (n=50), which received standard sterile gauze dressing with an iodine-based disinfectant, and an intervention group (n=50), treated with the ciNPWT system (Vivano® by HARTMANN) for 5 days postoperatively. The primary outcome was the incidence of SSI within one year after surgery. Secondary outcomes included the influence of factors such as age, sex, smoking status, and hernia size on SSI occurrence. The study was approved by the Ethics Committee at the University Hospital Ostrava, adhering to the ethical standards of the Helsinki Declaration. Results: The incidence of SSI was lower in the ciNPWT group compared to the standard care group (4% vs. 12%), though this difference did not reach statistical significance. No significant effect of sex or smoking status on SSI was observed. The control group had a shorter mean length of hospital stay. Larger hernias in the non-ciNPWT group were more prone to SSIs, as expected. Conclusions: Although limited by a small sample size, the findings suggest that ciNPWT may be associated with a reduced rate of SSI following ventral hernia repair. Further studies with larger populations are needed to confirm these results.


Assuntos
Hérnia Ventral , Herniorrafia , Tratamento de Ferimentos com Pressão Negativa , Polipropilenos , Telas Cirúrgicas , Infecção da Ferida Cirúrgica , Humanos , Tratamento de Ferimentos com Pressão Negativa/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Infecção da Ferida Cirúrgica/prevenção & controle , Infecção da Ferida Cirúrgica/epidemiologia , Idoso , Herniorrafia/métodos , Herniorrafia/efeitos adversos , Hérnia Ventral/cirurgia , Adulto , Resultado do Tratamento , Incidência
6.
Pak J Med Sci ; 40(5): 946-950, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38827864

RESUMO

Background & Objective: Laparoscopic surgery is generally considered as better than open surgery in terms of less complications, minimal hospital stays and quick healing of the wounds. Our objective was to compare the immediate and early outcome of the different incarcerated hernias of anterior abdominal wall operated on as emergency cases by open and laparoscopic approach. Methods: This is a retrospective comparative study which was conducted at two hospitals of AlAhsa city of the Eastern region of the Kingdom of Saudi Arabia from July, 2017 to June, 2022. The data were retrieved from the medical records of the hospitals. All male and female patients having different types of incarcerated hernias of anterior abdominal wall presenting to the emergency room were included in the study. The patients were divided in two groups; those who were operated on by open approach (Group-I) and those who were operated on by laparoscopic approach (Group-II). Results: Out of total 70 male and female patients, 42 were in Group-I and 28 in Group-II. The variety of the incarcerated hernias in both groups overall was para-umbilical 26(37.14%), incisional 18(25.71%), inguinal (right & left) 17(24.28%) and epigastric 9(12.86%). The mean operative time taken by Group I and II was 126.07 (±9.728) and 98.57 (±10.079) minutes respectively with a difference of 27.50 minutes (p=0.807). The mean hospital stay of the patients in Group I and II was 1.36(±0.719) and 1.57(±0.997) days respectively (p=0.482). The post-operative complications rate in Group-I was 6(14.28%) and in Group-II, 6(21.43%) (p=0.658). Overall, 12(17.14%) patients developed the complications in both groups. When the number of the complications is compared, it shows that there was no significant difference between the two groups (p=0.583). Conclusion: Laparoscopic approach is not superior to the open approach in the terms of the immediate and early outcome/complications of the incarcerated hernias of the anterior abdominal wall operated as emergency cases in this study.

7.
Surg Endosc ; 37(12): 9263-9274, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37880447

RESUMO

BACKGROUND: The effects of hernia repair on testicular function remain uncertain, regardless of the technique used. Studies that analyze testicular volume and flow after hernia repair or hormonal measurements are scarce and show contradictory results. This study aimed to evaluate the impact of bilateral inguinal hernia repair on male fertility in surgical patients in whom the Lichtenstein and laparoscopic transabdominal preperitoneal (TAPP) techniques were used. METHODS: A randomized clinical trial comparing open (Lichtenstein) versus laparoscopic (TAPP) hernia repair using polypropylene mesh was performed in 48 adult patients (20 to 60 years old) with primary bilateral inguinal hernia. Patients were evaluated preoperatively and 90 and 180 postoperative (PO) days. Sex hormones (Testosterone, FSH, LH and SHGB) analysis, testicular ultrasonography, semen quality sexual activity changes and quality of life (QoL) were performed. Postoperative pain was evaluated using the visual analog scale (VAS). RESULTS: Thirty-seven patients with aged of 44 ± 11 years were included, 19 operated on Lichtenstein and 18 operated on TAPP. The surgical time was similar between techniques. The pain was greater in the Lichtenstein group on the 7th PO day. The biochemical and hormonal analyses, testicular ultrasonography (Doppler, testicular volume, and morphological findings) and sperm quality were similar between groups. However, the sperm morphology was better in the Lichtenstein group after 180 days (p < 0.05 vs. preoperative) and two patients who underwent Lichtenstein hernia repair had oligospermia after 180 days. The QoL evaluation showed a significant improvement after surgery in the following domains: physical function, role emotional, bodily pain and general health (p < 0.05). On comparison of Lichtenstein vs. TAPP none of the domains showed statistically significant differences. No patient reported sexual changes. CONCLUSION: Bilateral inguinal hernia repair with polypropylene mesh, whether using Lichtenstein or TAPP, does not impair male fertility in terms of long-term outcomes. TRIAL REGISTRATION: Approved by the Ethics Committee for the Analysis of Research Projects (CAPPesq) of the HC/FMUSP, Number 2.974.457, in June 2015, Registered on Plataforma Brasil in October 2015 under Protocol 45535015.4.0000.0068. Registered on Clinicaltrials.gov, NCT05799742. Enrollment of the first subject in January 2016.


Assuntos
Hérnia Inguinal , Laparoscopia , Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Fertilidade , Hérnia Inguinal/cirurgia , Herniorrafia/métodos , Laparoscopia/métodos , Dor Pós-Operatória/cirurgia , Polipropilenos , Qualidade de Vida , Sêmen , Análise do Sêmen , Telas Cirúrgicas , Resultado do Tratamento
8.
Surg Endosc ; 37(12): 9105-9115, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37798529

RESUMO

BACKGROUND: Inguinal hernia repair is among the most frequently performed surgical procedures. Alternatives to penetrating mesh fixation, such as surgical glue, are being investigated for their potential benefit in reducing chronic pain. The aim of this study was to assess the efficacy of the n-hexyl cyanoacrylate glue Ifabond™ for mesh fixation in laparoscopic inguinal hernia repair. METHODS: This prospective, multicenter, single-arm study collected data from laparoscopic inguinal hernia repairs using Ifabond™ (Peters Surgical, Boulogne-Billancourt Cedex, France) and a standard [Promesh® SURG ST (Peters Surgical)/Biomesh® P1 (Cousin Biotech, Wervicq-Sud, France)] or lightweight [Promesh® SURG LI (Peters Surgical)/Premium® Implant (Cousin Biotech)] polypropylene mesh. The primary endpoint was postoperative pain [100-scale Visual Analog Scale (VAS)]. Secondary endpoints were complications, hernia recurrences, and quality of life (QoL) (EQ-5D-3L health index and EQ-VAS). Patients were followed up at 5 weeks and 12 months after surgery. RESULTS: Six-hundred and thirteen patients underwent laparoscopic inguinal hernia repair. Postoperative pain decreased at 5-week (3.97 ± 10.04; p < 0.0001) and 12-month (3.83 ± 11.26; p < 0.0001) follow-up compared with before surgery (26.96 ± 19.42). One hundred and fifteen patients (13.74%) experienced chronic pain in the groin at 12-month follow-up, of whom 14 (2.67%) required analgesics. There were 6 patients with major morbidities and one patient died of an unrelated cause. Two hernia recurrences occurred within 12-month follow-up. Patients' QoL increased from an EQ-5D-3L index score of 0.82 ± 0.19 preoperatively to 0.90 ± 0.15 at 5 weeks (p < 0.0001) and 0.92 ± 0.15 at 12 months after surgery (p < 0.0001). The EQ-VAS general health scoring increased from 79.03 ± 12.69 preoperatively to 84.31 ± 9.97 at 5-week (p < 0.0001) and 84.16 ± 14.48 at 12-month follow-up (p < 0.0001). CONCLUSIONS: Ifabond™ (Peters Surgical) is a safe, reliable, and feasible fixation method for laparoscopic inguinal hernia repair with a very high surgeon satisfaction score, improved patients' QoL, and comparable risk of developing chronic pain and postoperative complications as described in the literature.


Assuntos
Dor Crônica , Hérnia Inguinal , Laparoscopia , Humanos , Hérnia Inguinal/cirurgia , Hérnia Inguinal/complicações , Qualidade de Vida , Dor Crônica/etiologia , Cianoacrilatos , Laparoscopia/métodos , Estudos Prospectivos , Telas Cirúrgicas/efeitos adversos , Dor Pós-Operatória/epidemiologia , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Herniorrafia/métodos , Recidiva
9.
Int Urogynecol J ; 34(1): 67-78, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36018353

RESUMO

INTRODUCTION AND HYPOTHESIS: Our aim was to compare the mid-term results of native tissue, biological xenograft and polypropylene mesh surgery for women with vaginal wall prolapse. METHODS: A total of 1348 women undergoing primary transvaginal repair of an anterior and/or posterior prolapse were recruited between January 2010 and August 2013 from 35 UK centres. They were randomised by remote allocation to native tissue surgery, biological xenograft or polypropylene mesh. We performed both 4- and 6-year follow-up using validated patient-reported outcome measures. RESULTS: At 4 and 6 years post-operation, there was no clinically important difference in Pelvic Organ Prolapse Symptom Score for any of the treatments. Using a strict composite outcome to assess functional cure at 6 years, we found no difference in cure among the three types of surgery. Half the women were cured at 6 years but only 10.3 to 12% of women had undergone further surgery for prolapse. However, 8.4% of women in the mesh group had undergone further surgery for mesh complications. There was no difference in the incidence of chronic pain or dyspareunia between groups. CONCLUSIONS: At the mid-term outcome of 6 years, there is no benefit from augmenting primary prolapse repairs with polypropylene mesh inlays or biological xenografts. There was no evidence that polypropylene mesh inlays caused greater pain or dyspareunia than native tissue repairs.


Assuntos
Dispareunia , Prolapso de Órgão Pélvico , Prolapso Uterino , Humanos , Feminino , Prolapso Uterino/cirurgia , Seguimentos , Dispareunia/etiologia , Dispareunia/epidemiologia , Polipropilenos , Telas Cirúrgicas/efeitos adversos , Procedimentos Cirúrgicos em Ginecologia/métodos , Prolapso de Órgão Pélvico/cirurgia , Resultado do Tratamento
10.
Int Urogynecol J ; 33(2): 327-335, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33860812

RESUMO

INTRODUCTION AND HYPOTHESIS: We compared the impact of a mesh manufactured from the soft elastomer polydimethylsiloxane (PDMS) to that of a widely used lightweight polypropylene (PP) mesh. To achieve a similar overall device stiffness between meshes, the PDMS mesh was made with more material and therefore was heavier and less porous. We hypothesized that the soft polymer PDMS mesh, despite having more material, would have a similar impact on the vagina as the PP mesh. METHODS: PDMS and PP meshes were implanted onto the vaginas of 20 rabbits via colpopexy. Ten rabbits served as sham. At 12 weeks, mesh-vagina complexes were explanted and assessed for contractile function, histomorphology, total collagen, and glycosaminoglycan content. Outcome measures were compared using one-way ANOVA and Kruskal-Wallis testing with appropriate post-hoc testing. RESULTS: Relative to sham, vaginal contractility was reduced following the implantation of PP (p = 0.035) but not the softer PDMS (p = 0.495). PP had an overall greater negative impact on total collagen and glycosaminoglycan content, decreasing by 53% (p < 0.001) and 54% (p < 0.001) compared to reductions of 35% (p = 0.004 and p < 0.001) with PDMS. However, there were no significant differences in the contractility, collagen fiber thickness, total collagen, and glycosaminoglycan content between the two meshes. CONCLUSIONS: Despite having a substantially higher weight, PDMS had a similar impact on the vagina compared to a low-weight PP mesh, implicating soft polymers as potential alternatives to PP. The notion that heavyweight meshes are associated with a worse host response is not applicable when comparing across materials.


Assuntos
Prolapso de Órgão Pélvico , Polipropilenos , Animais , Elastômeros , Feminino , Humanos , Prolapso de Órgão Pélvico/cirurgia , Coelhos , Telas Cirúrgicas , Vagina/cirurgia
11.
J Minim Invasive Gynecol ; 29(12): 1317-1322, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35964942

RESUMO

STUDY OBJECTIVE: To describe the results of mesh exposure and prolapse recurrence of transvaginal natural orifice transluminal endoscopic surgery (vNOTES) for sacrocolpopexy after more than 24 months of postoperative follow-up. DESIGN: A retrospective cohort study. SETTING: A university hospital. PATIENTS: Women with uterine prolapse who underwent vNOTES sacrocolpopexy with an ultralightweight polypropylene mesh between May 2018 and March 2020. INTERVENTIONS: vNOTES sacrocolpopexy. MEASUREMENTS AND MAIN RESULTS: Of 57 women, 55 women (96.5%) were included in the final analysis. The mean follow-up duration was 35.5 ± 7.6 (24-46) months. The total incidence of mesh exposure was 3 of 55 (5.5%). The total incidence of prolapse recurrence was 3 of 55 (5.5%). The changes in the Pelvic Organ Prolapse Quantification System scores, including Aa, Ba, C, Ap, Bp, and total vaginal length values, showed significant improvement after surgery (p <.05 for all). CONCLUSION: The study demonstrates that vNOTES sacrocolpopexy appears to be an effective option with low risks of mesh exposure and prolapse recurrence. Studies including more patients and longer follow-up periods should be performed before a clear conclusion can be reached.


Assuntos
Cirurgia Endoscópica por Orifício Natural , Prolapso de Órgão Pélvico , Prolapso Uterino , Humanos , Feminino , Telas Cirúrgicas/efeitos adversos , Estudos Retrospectivos , Prolapso de Órgão Pélvico/cirurgia , Cirurgia Endoscópica por Orifício Natural/efeitos adversos , Cirurgia Endoscópica por Orifício Natural/métodos , Vagina/cirurgia , Resultado do Tratamento
12.
Arch Gynecol Obstet ; 305(3): 641-649, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34845538

RESUMO

PURPOSE: Many different surgical approaches have been established for the repair of a pelvic organ prolapse. Especially in laparoscopic surgery, it is important to generate easy surgical techniques with similar stability. This study shall simplify the choice of mesh by evaluating three polypropylene meshes regarding their biomechanical properties. METHODS: Biomechanical testing was performed in the porcine model. The meshes are fixated on porcine fresh cadaver cervices after subtotal hysterectomy. The apical part of the mesh is fixated with parallel screw clamps at the testing frame. Forty-one trials were performed overall, subdivided into four subgroups. The groups differ in mesh type and fixation method. Maximum load, displacement at failure and stiffness parameters were evaluated with an Instron 5565® test frame. RESULTS: SERATEX® E11 PA (E11) showed the highest values for maximum load (199 ± 29N), failure displacement (71 ± 12 mm) and stiffness (3.93 ± 0.59 N/mm). There was no significant difference in all three evaluated parameters between SERATEX® B3 PA (B3) and SERATEX® SlimSling® with bilateral fixation (SSB). SERATEX® SlimSling® with unilateral fixation (SSU) had the lowest stiffness (0.91 ± 0.19 N/mm) and maximum load (30 ± 2 N) but no significant difference in displacement at failure. CONCLUSION: All meshes achieved a good tensile strength, but the results of maximum load show that the E11 is superior to the other meshes. Through a bilateral fixation of SERATEX® SlimSling®, a simple operating method is generated without a loss of stability.


Assuntos
Diafragma da Pelve , Prolapso de Órgão Pélvico , Animais , Fenômenos Biomecânicos , Feminino , Diafragma da Pelve/cirurgia , Prolapso de Órgão Pélvico/cirurgia , Polipropilenos , Telas Cirúrgicas , Suínos , Resistência à Tração
13.
J Obstet Gynaecol ; 42(6): 2115-2120, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35166189

RESUMO

We investigated the frequency of further surgery post-artificial mesh (ProliftTM) repair of pelvic organ prolapse. In total, 257 patients who underwent ProliftTM repair were evaluated for further surgery frequency, clinical outcomes, and demographic characteristics. Thirty-eight (14.7%) patients underwent further surgery (median time to reoperation, 9.5 months; range, 6-22 months). Six (2.3%) patients underwent prolapse repair at a different (5 patients, 1.9%) or same site (1 patient, 0.3%). One underwent posterior ProliftTM repair; four, laparoscopic sacrocolpopexy; and one, vaginal hysterectomy. Eight (3.1%) underwent surgery for complications; seven (2.7%) required further surgery for mesh exposure (median, 8 months) and one (0.3%) required further surgery for mesh infection (1 month). Twenty-four (9.3%) received further surgery for stress urinary incontinence (median, 8.5 months). Despite the low frequency of further surgery post-ProliftTM repair, mesh-related complications should be considered. Careful long-term follow-up is necessary.Impact StatementWhat is already known on this subject? It is widely known that vaginal mesh is used as treatment for pelvic organ prolapse (POP). Vaginal mesh is one of the treatment options for POP. However, it received a bad reputation following reports of complications associated with its use, leading to discontinuation of vaginal mesh in many countries.What the results of this study revealed? The findings of this study show that few patients who received ProliftTM repair required further surgery. The surgeries included surgery for non-POP-related conditions; subsequent surgery for stress urinary incontinence (SUI); surgery for complications including mesh exposure and infection; primary prolapse surgery for a different site and repeat surgery; and a repeat operation for prolapse arising from the same site.What are the implications of these findings in clinical practice and/or further research? Based on the outcome of this study, transvaginal ProliftTM mesh repair is a reasonably safe and effective treatment for POP. Despite withdrawal of all mesh products from the market as instructed by the FDA, this study suggested the need to re-evaluate the role of vaginal mesh as a treatment option for POP.


Assuntos
Prolapso de Órgão Pélvico , Slings Suburetrais , Incontinência Urinária por Estresse , Feminino , Seguimentos , Humanos , Prolapso de Órgão Pélvico/complicações , Prolapso de Órgão Pélvico/cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Slings Suburetrais/efeitos adversos , Telas Cirúrgicas/efeitos adversos , Resultado do Tratamento , Incontinência Urinária por Estresse/cirurgia
14.
Chin J Traumatol ; 25(2): 122-124, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34034947

RESUMO

Surgical stabilization of the flail chest is challenging and has no established guidelines. Chest wall integrity and stability are the main factors that ensure the protection of intrathoracic organs and an adequate respiratory function. Here, we report a novel chest wall reconstruction technique in a 45-year-old man with a traumatic left flail chest and open pneumothorax diagnosed both clinically and radiographically. Rib approximation and chest wall reconstruction was done using intercostal figure-of-eight suture and polypropylene mesh with vascularized musculofascial flap. The patient improved gradually and was discharged after three weeks of total hospital stay. He returned to regular working after a month with no evidence of respiratory distress or paradoxical chest movement. Follow-up visit at one year revealed no lung hernia or paradoxical chest movement. This is a novel, feasible and cost-effective modification of chest wall reconstruction that can be adopted for thoracic wall repair in case of open flail chest, which needs emergency surgical interventions even in resource constraint settings.


Assuntos
Tórax Fundido , Parede Torácica , Tórax Fundido/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Polipropilenos , Telas Cirúrgicas , Suturas , Parede Torácica/cirurgia
15.
BJOG ; 128(13): 2180-2189, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34473896

RESUMO

OBJECTIVE: To report complication rates following prolapse surgery using polypropylene mesh inlay, polypropylene mesh kit, biological collagen xenografts and native tissue repairs. DESIGN: Secondary analysis of the PROSPECT randomised controlled trial and cohort study. SETTING: Thirty-five UK hospitals. POPULATION: A total of 2632 women undergoing anterior and/or posterior vaginal prolapse repair. METHODS: Event rates were calculated for all complications. Analysis was by treatment received. MAIN OUTCOME MEASURES: IUGA/ICS classification of complications and validated patient reported outcome measures. RESULTS: At baseline, 8.4% of women had 'generic' pain/discomfort; at 2 years following surgery, there was an improvement in all four groups; however, 3.0% of women developed de novo extreme generic pain. At 24 months de novo vaginal tightness occurred in 1.6% of native tissue, 1.2% of biological xenograft, 0.3% of mesh inlay and 3.6% of mesh kit. Severe dyspareunia occurred in 4.8% of native tissue, 4.2% of biological xenograft, 3.4% of mesh inlay repairs and 13.0% of mesh kits. De novo severe dyspareunia occurred in 3.5% of native tissue, 3.5% of biological xenograft, 1.4% of mesh inlays and 4.8% of mesh kits. Complications requiring re-admission to hospital, unrelated to mesh, affected 1 in 24 women; the most common reasons for re-admission were vaginal adhesions, urinary retention, infection and constipation. CONCLUSIONS: This is the first study to address the complications of vaginal mesh used for prolapse surgery alongside data from both native tissue and biological xenograft. It demonstrates the complexity of assessing pain and that all types of prolapse surgery have low surgical morbidity and a low rate of severe complications. TWEETABLE ABSTRACT: A prospective study of 2362 women undergoing vaginal mesh, xenograft or native tissue repair found low surgical morbidity and low rates of severe complications.


Assuntos
Colágeno , Procedimentos Cirúrgicos em Ginecologia/métodos , Xenoenxertos , Prolapso de Órgão Pélvico/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Polipropilenos , Prolapso Uterino/cirurgia , Adulto , Estudos de Coortes , Colágeno/uso terapêutico , Feminino , Xenoenxertos/transplante , Humanos , Pessoa de Meia-Idade , Satisfação do Paciente , Polipropilenos/uso terapêutico , Complicações Pós-Operatórias , Estudos Prospectivos , Telas Cirúrgicas , Resultado do Tratamento
16.
Int Urogynecol J ; 32(1): 47-55, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32651643

RESUMO

INTRODUCTION AND HYPOTHESIS: The aim of the study is to demonstrate the impact of the size of implanted mesh in relation to its immunohistochemical reaction implanted into animal models. METHODS: An experimental study utilizing 54 female Sprague Dawley (SD) rats was divided into five groups: control, sham, and study groups (mesh-small [M-S], mesh-medium [M-M], mesh-large [M-L]). The M-S group used a mesh size of 0.2 × 0.2 cm, the M-M group a mesh size of 0.5 × 0.5 cm, and the M-L a mesh size of 0.7 × 1.0 cm. The sham group underwent vaginal dissection with no mesh implantation. The rats were sacrificed using isoflurane overdose on days 7 and 30. The mesh with the surrounding vaginal and bladder wall tissues were removed and processed for histochemical and western blot analysis. RESULTS: There is a significant increase in IL-1 and TNF-α immunoreactivity in the M-M and M-L groups on day 7 when compared with the sham group with p values of 0.001 and < 0.001 respectively. M-L showed significantly higher immunoreactivity to TNF-α persisting until day 30. All study groups presented a significantly higher immunoreactivity to MMP-2 and NGF on day 7. However, reactivity to NGF does not persist to day 30 in all groups. Immunoreactivity to CD 31 on days 7 and 30 appears significantly greater in the M-M and M-L groups, with the reaction in the M-L group continuing until day 30. CONCLUSION: Mesh size is directly proportional to the inflammatory reaction in the host tissue. The prolonged inflammatory process leads to delayed tissue remodeling and angiogenesis, which could delay mesh-tissue integration.


Assuntos
Polipropilenos , Telas Cirúrgicas , Animais , Feminino , Inflamação , Ratos , Ratos Sprague-Dawley , Telas Cirúrgicas/efeitos adversos , Bexiga Urinária
17.
Int Urogynecol J ; 32(1): 111-117, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32533213

RESUMO

INTRODUCTION AND HYPOTHESIS: Debate persists over whether surgery to correct pelvic organ prolapse (POP) should be combined with midurethral sling (MUS) insertion. The aim of this study was to evaluate the incidence of stress urinary incontinence (SUI) up to 12 months after transvaginal mesh surgery, with or without MUS, and to identify risk factors for postoperative SUI. METHODS: This retrospective single-center study included patients who underwent transvaginal mesh surgery with Uphold™ between October 2010 and December 2017. The primary outcome was the prevalence of SUI at 12 months postoperatively. Univariate and multivariate logistic regression was used to identify risks factors for postoperative SUI. RESULTS: Of the 308 women included, 123 (40%) were continent (no SUI), 108 (35%) had SUI, and 76 (25%) had occult SUI. Forty-nine patients (15.9%) had a concomitant MUS procedure. At 12 months after surgery, 35.9% of patients without concomitant MUS had SUI vs 14.3% with (p = 0.003). Thirty-five patients (29%) developed de novo SUI. Postoperative complications were more common in patients with concomitant MUS (30.6% vs 17%; p = 0.003). The best predictor of postoperative SUI was the presence of preoperative SUI (OR 2.52 (1.25-5.09). Concomitant MUS (p < 0.001), and prior POP surgery (p = 0.034) were protective factors for postoperative SUI. CONCLUSION: Preoperative SUI is the most important risk factor for postoperative SUI. However, given the higher risk of postoperative complications with concomitant MUS and the acceptable rate of de novo SUI rate without it, two-stage surgery seems preferable for patients with preoperative SUI.


Assuntos
Prolapso de Órgão Pélvico , Slings Suburetrais , Incontinência Urinária por Estresse , Feminino , Humanos , Prolapso de Órgão Pélvico/cirurgia , Estudos Retrospectivos , Fatores de Risco , Slings Suburetrais/efeitos adversos , Telas Cirúrgicas/efeitos adversos , Incontinência Urinária por Estresse/epidemiologia , Incontinência Urinária por Estresse/etiologia , Incontinência Urinária por Estresse/cirurgia
18.
Langenbecks Arch Surg ; 406(5): 1651-1657, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33733286

RESUMO

PURPOSE: The use of synthetic materials in emergency surgery for abdominal wall hernia in a potentially infected operating field has long been debated. In the present study, we evaluated the outcome of mesh prostheses in the management of incarcerated and strangulated abdominal wall hernias with or without organ resection. METHODS: Between March 2012 and January 2020, medical records of 301 patients who underwent emergency surgery for incarcerated and strangulated abdominal wall hernias were retrospectively evaluated. The interventions were exclusively realized by two surgical teams, one of which used polypropylene mesh prostheses (group I), whereas the second team performed primary hernia repair (group II). The outcome of patients was observed for a mean follow-up period of 18.2 months. Categorical data were analyzed with the χ2 test or likelihood ratio. Logistic regression was used for adjustments in multivariate analysis. Statistical analyses were realized with SPSS, version 18. P values < 0.05 were considered statistically significant. For multiple comparisons between types of hernia, the significance level was set to P < 0.0083 according to Bonferroni adjustment. RESULTS: Of the 301 patients, 190 were men (63.1%), and 111 were women (36.9%). The mean age was 59,98 years (range 17-92). Overall, 226 (75.1%) patients were treated with synthetic mesh replacement. One hundred two organ resections (34%) were performed involving the omentum, small intestine, colon, and appendix. No significant difference was identified in terms of postoperative complications, between the two groups both in patients who underwent organ resection and in patients who did not. CONCLUSION: Synthetic materials may safely be used in the emergency management of incarcerated and strangulated groin and abdominal wall hernias in patients with or without organ resection, although they cannot formally be recommended due to the limited number of cases of the present study.


Assuntos
Hérnia Inguinal , Hérnia Ventral , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Virilha/cirurgia , Hérnia Inguinal/cirurgia , Hérnia Ventral/cirurgia , Herniorrafia/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Próteses e Implantes , Estudos Retrospectivos , Telas Cirúrgicas , Adulto Jovem
19.
Arch Gynecol Obstet ; 304(4): 965-973, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34405286

RESUMO

PURPOSE: Visualization of the implanted mesh after a pelvic floor repair surgery is important for evaluating mesh-related complications. We made an X-ray-detectable mesh and studied the histocompatibility and toxicity of it. METHODS: A thin barium sulfate thread was weaved on a traditional polypropylene mesh to make it X-ray detectable. The cytotoxicity of the mesh was tested by the MTT assay on L929 cell line. The histocompatibility and toxicity of mesh were evaluated in rabbits. Meshes were first implanted intraperitoneally. On postoperative day 7, bloods were tested to estimate the acute toxicity of meshes. After 6 months, rabbits were sacrificed and local inflammatory reaction and tissue regeneration at implantation sites were estimated by the HE stain and Masson stain. In addition, CT scans were performed after surgeries to display the location and shape of implanted meshes. RESULTS: Compared to the polypropylene mesh group, no significant difference was observed in the X-ray-detectable mesh group on both in vitro cytotoxicity and in vivo acute and chronic toxicity. The amounts of extra cellular matrix between two groups did not differ. Through CT scan and 3D remodeling, the barium sulfate thread clearly revealed the position and shape of the X-ray-detectable mesh, whereas the traditional mesh was invisible under CT scan. CONCLUSION: Adding a thin barium sulfate thread on the polypropylene mesh does not change its histocompatibility or toxicity in rabbit model. The barium sulfate thread can effectively show the location and shape of implanted mesh under CT scan.


Assuntos
Procedimentos de Cirurgia Plástica , Telas Cirúrgicas , Animais , Teste de Materiais , Polipropilenos , Coelhos , Telas Cirúrgicas/efeitos adversos , Raios X
20.
Scott Med J ; 66(3): 158-161, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34162241

RESUMO

INTRODUCTION: Polypropylene (PP) meshes are safe synthetic products used for hernia repairs and associated with minimal complication. Chronic inflammation is thought to play a pathophysiological role in the development of cancer.Case presentation: We present a 67-year-old female case of squamous cell-cancer (SCC) that developed due to mesh after umbilical hernia operation. The mass in the anterior abdominal wall was totally resected. Pathology was reported as T2N0, moderately differentiated acantholytic type SCC. No recurrence or complication was detected in the fourth-month follow-up. CONCLUSION: Cancer development after mesh is very rare and our case is the third case in the literature. Cancer development should be kept in mind in patients presenting with ulcerated masses if do not regress with infection treatment after mesh application.


Assuntos
Carcinoma de Células Escamosas , Hérnia Umbilical , Idoso , Carcinoma de Células Escamosas/cirurgia , Feminino , Hérnia Umbilical/etiologia , Hérnia Umbilical/cirurgia , Herniorrafia/efeitos adversos , Humanos , Recidiva Local de Neoplasia , Telas Cirúrgicas/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA