Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 159
Filtrar
1.
Eur J Clin Microbiol Infect Dis ; 43(3): 605-610, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38112967

RESUMO

FASTinov® developed a rapid antimicrobial susceptibility test that includes the purification of a bacterial suspension directly from positive blood cultures (BC). In order to streamline laboratory workflow, the use of the bacterial suspension obtained through FASTinov® sample prep was tested for identification (ID) by matrix absorption laser deionization-time of flight mass spectrometry (MALDI-TOF MS) (Bruker) in 364 positive BC, and its accuracy assessed comparing with the MALDI-TOF MS ID of the next-day subcultured colonies. FASTinov sample prep was highly reliable for rapid ID directly from BC with proportion of agreement of 94.9% for Gram-positive and 96.3% for Gram-negative bacteria.


Assuntos
Bacteriemia , Hemocultura , Humanos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Bactérias , Bactérias Gram-Negativas , Laboratórios , Bacteriemia/microbiologia
2.
BMC Infect Dis ; 24(1): 566, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844852

RESUMO

BACKGROUND: Early and appropriate antibiotic treatment improves the clinical outcome of patients with sepsis. There is an urgent need for rapid identification (ID) and antimicrobial susceptibility testing (AST) of bacteria that cause bloodstream infection (BSI). Rapid ID and AST can be achieved by short-term incubation on solid medium of positive blood cultures using MALDI-TOF mass spectrometry (MS) and the BD M50 system. The purpose of this study is to evaluate the performance of rapid method compared to traditional method. METHODS: A total of 124 mono-microbial samples were collected. Positive blood culture samples were short-term incubated on blood agar plates and chocolate agar plates for 5 ∼ 7 h, and the rapid ID and AST were achieved through Zybio EXS2000 MS and BD M50 System, respectively. RESULTS: Compared with the traditional 24 h culture for ID, this rapid method can shorten the cultivation time to 5 ∼ 7 h. Accurate organism ID was achieved in 90.6% of Gram-positive bacteria (GP), 98.5% of Gram-negative bacteria (GN), and 100% of fungi. The AST resulted in the 98.5% essential agreement (EA) and 97.1% category agreements (CA) in NMIC-413, 99.4% EA and 98.9% CA in PMIC-92, 100% both EA and CA in SMIC-2. Besides, this method can be used for 67.2% (264/393) of culture bottles during routine work. The mean turn-around time (TAT) for obtaining final results by conventional method is approximately 72.6 ± 10.5 h, which is nearly 24 h longer than the rapid method. CONCLUSIONS: The newly described method is expected to provide faster and reliable ID and AST results, making it an important tool for rapid management of blood cultures (BCs). In addition, this rapid method can be used to process most positive blood cultures, enabling patients to receive rapid and effective treatment.


Assuntos
Bactérias , Testes de Sensibilidade Microbiana , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Humanos , Testes de Sensibilidade Microbiana/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Bactérias/efeitos dos fármacos , Bactérias/isolamento & purificação , Antibacterianos/farmacologia , Fungos/efeitos dos fármacos , Fungos/isolamento & purificação , Hemocultura/métodos , Bactérias Gram-Negativas/efeitos dos fármacos , Bactérias Gram-Negativas/isolamento & purificação , Fatores de Tempo , Bactérias Gram-Positivas/efeitos dos fármacos , Bactérias Gram-Positivas/isolamento & purificação , Sepse/microbiologia , Sepse/tratamento farmacológico , Sepse/diagnóstico
3.
Phytochem Anal ; 35(6): 1278-1285, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38649268

RESUMO

INTRODUCTION: Calculus bovis (C. bovis) is a typical traditional Chinese medicine (TCM) derived from animals, which has a remarkable curative effect and high price. OBJECTIVES: Rapid identification of C. bovis from different types was realized based on spectral technology, and a rapid quantitative analysis method for the main quality control indicator bilirubin was established. METHODS: We conducted a supervised and unsupervised pattern recognition study on 44 batches of different types of C. bovis by five spectral pretreatment methods. Three variable selection methods were used to extract the essential information, and the partial least squares regression (PLSR) quantitative model of bilirubin by near-infrared (NIR) spectroscopy was constructed. RESULTS: The partial least squares discriminant analysis (PLS-DA) model could achieve 100% accuracy in identifying different types of C. bovis. The R2 of the NIR quantitative model was 0.979, which is close to 1, and the root mean square error of calibration (RMSEC) was 2.3515, indicating the good prediction ability of the model. CONCLUSION: The study was carried out to further improve the basic data of quality control of C. bovis and help the high-quality development of TCM derived from animals.


Assuntos
Medicina Tradicional Chinesa , Controle de Qualidade , Espectroscopia de Luz Próxima ao Infravermelho , Animais , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Análise dos Mínimos Quadrados , Medicamentos de Ervas Chinesas/química , Análise Discriminante , Bilirrubina/análise
4.
Eur J Clin Microbiol Infect Dis ; 42(11): 1355-1363, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37794128

RESUMO

PURPOSE: This study aims to evaluate the performance of two latest generation matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) systems in routine laboratory settings, focusing on turnaround time (TAT), time to results (TTR), hands-on time, and identification rate. METHODS: We conducted a time and motion study on three workflow scenarios to simulate different laboratory settings. Overall, 618 bacterial isolates from a tertiary hospital's laboratory were processed using the VITEK MS PRIME (bioMérieux) and the MALDI Biotyper sirius (Bruker Daltonics) and their corresponding databases VITEK IVD Database 3.2 and MBT reference library 12. RESULTS: The target preparation process showed no significant difference in TAT, but the Biotyper workflow had a shorter hands-on time by 3 to 6 min. In the measurement process, TTR was three to five times shorter for the Biotyper sirius while hands-on time was significantly shorter for VITEK MS PRIME (approximately 1.5 min per target). The identification rate without retesting was 97.9% for VITEK MS PRIME and 98.9% for Biotyper sirius. Both systems achieved 100% agreement at genus and 96.2% at species level. CONCLUSION: Both systems exhibited excellent identification rates for routine bacterial isolates. Due to its high speed, the Biotyper sirius is suited for laboratories with high sample throughput and a workflow designed for processing larger batches. The VITEK MS PRIME, with its "load and go" system accommodating up to 16 targets, reduces hands-on time, making it a reasonable choice for laboratories with fewer identifications overall but a higher number of targets and a workflow designed for parallel processing on different workstations.


Assuntos
Laboratórios , Humanos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
5.
Ann Clin Microbiol Antimicrob ; 22(1): 62, 2023 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-37516885

RESUMO

BACKGROUND: The Accelerate PhenoTest® BC system (AXDX) is a novel assay for rapid bacterial identification and antimicrobial susceptibility (AST). We report an evaluation of its impact on treatment of patients with Gram-negative bacteremia (GNB) with a high risk of antimicrobial resistance (AMR). METHODS: A prospective single-center evaluation before and after implementation of AXDX in addition to standard-of-care (SOC) microbiology and antimicrobial stewardship program (ASP). Patients with GNB reported during laboratory working hours and prespecified risk factors for AMR were included. The primary outcome was an ASP-oriented beneficial antimicrobial change, defined as either an escalation of an inappropriate empiric treatment or de-escalation of a broad-spectrum treatment of a susceptible organism. Main secondary outcomes were time to an appropriate treatment, antimicrobial treatment duration, length of stay (LOS) and mortality. RESULTS: Included were 46 and 57 patients in the pre- and post-intervention periods, respectively. The median time to an AST-oriented beneficial change was 29.2 h vs. 49.6 h, respectively (p < 0.0001). There were no significant differences in the time to appropriate treatment, LOS or mortality. Antimicrobial treatment duration was longer during the intervention period (10 vs. 8 days, p = 0.007). AXDX failed to correctly identify pathogens in all 6 cases of polymicrobial bacteremia. In two cases patient care was potentially compromised due to inappropriate de-escalation. CONCLUSIONS: AXDX implementation resulted in a 20.4-hour shorter time to an ASP-oriented beneficial antimicrobial change. This should be weighed against the higher costs, the lack of other proven clinical benefits and the potential harm from mis-identification of polymicrobial bacteremias.


Assuntos
Antibacterianos , Bacteriemia , Humanos , Antibacterianos/uso terapêutico , Farmacorresistência Bacteriana , Estudos Prospectivos , Bacteriemia/tratamento farmacológico , Laboratórios
6.
Molecules ; 28(19)2023 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-37836715

RESUMO

This study aims to establish a rapid identification method based on the Proofman-LMTIA technique for distinguishing between Panax quinquefolium and Panax ginseng. By targeting specific 18S rDNA sequences, suitable primers and Proofman probes labeled FAM or JOE were designed for LMTIA. Initially, single-species-primer Proofman-LMTIA assays were performed separately for each ginseng type to optimize reaction temperature, assess sensitivity and specificity, and determine the detection limit. Subsequently, both sets of primers and their corresponding probes were combined in the same reaction system to further optimize reaction conditions, evaluate sensitivity, and assess stability. Finally, the developed Proofman-duplex-LMTIA technique was employed to detect P. quinquefolium and P. ginseng slices available in the market. Single-plex Proofman-LMTIA assays revealed that the optimal reaction temperature for both P. quinquefolium and P. ginseng was 62 °C. The sensitivity was as low as 1 pg/µL, with a detection limit of 0.1%, and both showed excellent specificity. The optimal temperature for Proofman-duplex-LMTIA assays was 58 °C. This method could simultaneously identify P. quinquefolium and P. ginseng. Testing 6 samples of P. ginseng and 11 samples of P. quinquefolium from the market resulted in a 100% positive rate for all samples. This study successfully established a rapid, simple, sensitive, and specific Proofman-duplex-LMTIA identification method for P. quinquefolium and P. ginseng. It provides an effective means for quality control of P. quinquefolium, P. ginseng, and related products.


Assuntos
Panax , Temperatura , Controle de Qualidade
7.
Zhongguo Zhong Yao Za Zhi ; 48(16): 4362-4369, 2023 Aug.
Artigo em Chinês | MEDLINE | ID: mdl-37802862

RESUMO

Puerariae Lobatae Radix, the dried root of Pueraria lobata, is a traditional Chinese medicine with a long history. Puerariae Lobatae Caulis as an adulterant is always mixed into Puerariae Lobatae Radix for sales in the market. This study employed hyperspectral imaging(HSI) to distinguish between the two products. VNIR lens(spectral scope of 410-990 nm) and SWIR lens(spectral scope of 950-2 500 nm) were used for image acquiring. Multi-layer perceptron(MLP), partial least squares discriminant analysis(PLS-DA), and support vector machine(SVM) were employed to establish the full-waveband models and select the effective wavelengths for the distinguishing between Puerariae Lobatae Caulis and Puerariae Lobatae Radix, which provided technical and data support for the development of quick inspection equipment based on HSI. The results showed that MLP model outperformed PLS-DA and SVM models in the accuracy of discrimination with full wavebands in VNIR, SWIR, and VNIR+SWIR lens, which were 95.26%, 99.11%, and 99.05%, respectively. The discriminative band selection(DBS) algorithm was employed to select the effective wavelengths, and the discrimination accuracy was 93.05%, 98.05%, and 98.74% in the three different spectral scopes, respectively. On this basis, the MLP model combined with the effective wavelengths within the range of 2 100-2 400 nm can achieve the accuracy of 97.74%, which was close to that obtained with the full waveband. This waveband can be used to develop quick inspection devices based on HSI for the rapid and non-destructive distinguishing between Puerariae Lobatae Radix and Puerariae Lobatae Caulis.


Assuntos
Pueraria , Imageamento Hiperespectral , Medicina Tradicional Chinesa , Algoritmos , Redes Neurais de Computação
8.
Zhongguo Zhong Yao Za Zhi ; 48(6): 1518-1525, 2023 Mar.
Artigo em Chinês | MEDLINE | ID: mdl-37005839

RESUMO

Since Curcumae Radix decoction pieces have multiple sources, it is difficult to distinguish depending on traditional cha-racters, and the mixed use of multi-source Curcumae Radix will affect its clinical efficacy. Heracles Neo ultra-fast gas phase electronic nose was used in this study to quickly identify and analyze the odor components of 40 batches of Curcumae Radix samples from Sichuan, Zhejiang, and Guangxi. Based on the odor fingerprints established for Curcumae Radix decoction pieces of multiple sources, the odor components was identified and analyzed, and the chromatographic peaks were processed and analyzed to establish a rapid identification method. Principal component analysis(PCA), discriminant factor analysis(DFA), and soft independent modeling cluster analysis(SIMCA) were constructed for verification. At the same time, one-way analysis of variance(ANOVA) combined with variable importance in projection(VIP) was employed to screen out the odor components with P<0.05 and VIP>1, and 13 odor components such as ß-caryophyllene and limonene were hypothesized as the odor differential markers of Curcumae Radix decoction pieces of diffe-rent sources. The results showed that Heracles Neo ultra-fast gas phase electronic nose can well analyze the odor characteristics and rapidly and accurately discriminate Curcumae Radix decoction pieces of different sources. It can be applied to the quality control(e.g., online detection) in the production of Curcumae Radix decoction pieces. This study provides a new method and idea for the rapid identification and quality control of Curcumae Radix decoction pieces.


Assuntos
Medicamentos de Ervas Chinesas , Medicamentos de Ervas Chinesas/análise , Nariz Eletrônico , China , Raízes de Plantas/química , Limoneno/análise , Cromatografia Líquida de Alta Pressão
9.
Sensors (Basel) ; 22(6)2022 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-35336302

RESUMO

Antimicrobial resistance, a global health concern, has been increasing due to inappropriate use of antibacterial agents. To facilitate early treatment of sepsis, rapid bacterial identification is imperative to determine appropriate antibacterial agent for better therapeutic outcomes. In this study, we developed a rapid PCR method, rapid cycle sequencing, and microchip electrophoresis, which are the three elemental technologies for DNA sequencing based on the Sanger sequencing method, for bacterial identification. We achieved PCR amplification within 13 min and cycle sequencing within 14 min using a rapid thermal cycle system applying microfluidic technology. Furthermore, DNA analysis was completed in 14 min by constructing an algorithm for analyzing and performing microchip electrophoresis. Thus, the three elemental Sanger-based DNA sequencing steps were accomplished within 41 min. Development of a rapid purification process subsequent to PCR and cycle sequence using a microchip would help realize the identification of causative bacterial agents within one hour, and facilitate early treatment of sepsis.


Assuntos
Bactérias , Eletroforese em Microchip , Bactérias/genética , Reação em Cadeia da Polimerase/métodos , Análise de Sequência de DNA/métodos , Tecnologia
10.
Zhongguo Zhong Yao Za Zhi ; 47(14): 3781-3787, 2022 Jul.
Artigo em Chinês | MEDLINE | ID: mdl-35850835

RESUMO

Since the current identification method for Paeoniae Radix Alba is complex in operation and long time-consuming with high requirements for technicians, the present study employed Heracles NEO ultra-fast gas phase electronic nose(E-nose) technology to identify raw and sulfur-fumigated Paeoniae Radix Alba decoction pieces in order to establish a rapid identification method for sulfur-fumigated Paeoniae Radix Alba. The odors of raw Paeoniae Radix Alba and its sulfur-fumigated products were analyzed by Heracles NEO ultra-fast gas phase E-nose to obtain the odor chromatographic information. The chemometric model was established, and the data were processed by principal component analysis(PCA), discriminant function analysis(DFA), soft independent modeling of class analogy(SIMCA), and partial least squares discriminant analysis(PLS-DA). The differential compounds of raw and sulfur-fumigated samples were qualitatively analyzed based on the Kovats retention index and Arochembase. As revealed by the comparison of gas chromatograms of raw and sulfur-fumigated Paeoniae Radix Alba, the heights of several peaks in the chromatograms before and after sulfur fumigation changed significantly. The peak(No.8) produced by ethylbenzene disappeared completely due to sulfonation reaction in the process of sulfur fumigation, indicating that ethylbenzene may be the key component in the identification of Paeoniae Radix Alba and its sulfur-fumigated products. In PCA, DFA, SIMCA, and PLS-DA models, the two types of samples were separated into two different regions, indicating that the established models can clearly distinguish between raw and sulfur-fumigated Paeoniae Radix Alba. The results showed that Heracles NEO ultra-fast gas phase E-nose technology could realize the rapid identification of raw and sulfur-fumigated Paeoniae Radix Alba, which provides a new method and idea for the rapid identification of sulfur-fumigated Chinese medicine.


Assuntos
Medicamentos de Ervas Chinesas , Paeonia , Medicamentos de Ervas Chinesas/química , Nariz Eletrônico , Fumigação/métodos , Paeonia/química , Extratos Vegetais , Enxofre/química
11.
J Clin Microbiol ; 59(2)2021 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-33208474

RESUMO

Identification of Candida auris is challenging and requires molecular or protein profiling-based approaches, availability of which is limited in many routine diagnostic laboratories, necessitating the development of a cost-effective, rapid, and reliable method of identification. The objective of this study was to develop a selective medium for C. auris identification. Eighteen C. auris and 30 non-C. auris yeasts were used for the standardization of the selective medium. Sodium chloride (10% to 13% concentration) and ferrous sulfate (8 mM to 15 mM) were added to yeast extract-peptone-dextrose (YPD) agar in various combinations followed by incubation at 37°C, 40°C, or 42°C for 2 to 3 days. For validation, 579 yeast isolates and 40 signal-positive Bactec blood culture (BC) broths were used. YPD agar comprising 12.5% NaCl and 9 mM ferrous sulfate incubated at 42°C for 48 h, named Selective Auris Medium (SAM), allowed selective growth of C. auris A total of 95% (127/133) of C. auris isolates tested grew on the standardized media within 48 h, and the remaining 6 isolates grew after 72 h, whereas the growth of 446 non-C. auris yeast isolates was completely inhibited. The specificity and sensitivity of the test medium were both 100% after 72 h of incubation. The positive and negative predictive values were also noted to be 100% after 72 h of incubation. The formulated selective medium can be used for the detection and identification of C. auris The SAM is inexpensive, can easily be prepared, and can be used as an alternative to molecular diagnostic tools in the clinical microbiology laboratory.


Assuntos
Candida , Candidíase , Ágar , Antifúngicos/uso terapêutico , Candidíase/diagnóstico , Candidíase/tratamento farmacológico , Meios de Cultura , Humanos , Laboratórios
12.
J Clin Microbiol ; 59(4)2021 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-33536293

RESUMO

Non-albicans Candida species are emerging in the nosocomial environment, with the multidrug-resistant (MDR) species Candida auris being the most notorious example. Consequently, rapid and accurate species identification has become essential. The objective of this study was to evaluate five commercially available chromogenic media for the presumptive identification of C. auris Two novel chromogenic formulations, CHROMagar Candida Plus (CHROMagar) and HiCrome C. auris MDR selective agar (HiMedia), and three reference media, CandiSelect (Bio-Rad), CHROMagar Candida (CHROMagar), and Chromatic Candida (Liofilchem), were inoculated with a collection of 9 genetically diverse C. auris strains and 35 strains from closely related comparator species. After 48 h of incubation, the media were evaluated for their ability to detect and identify C. auris All media had the same limitations in the differentiation of the more common species Candida dubliniensis and Candida glabrata Only on CHROMagar Candida Plus did C. auris colonies develop a species-specific coloration. Nevertheless, the closely related pathogenic species Candida pseudohaemulonii and Candida vulturna developed a similar appearance as C. auris on this medium. CHROMagar Candida Plus was shown to be superior in the detection and identification of C. auris, with 100% inclusivity for C. auris compared to 0% and 33% for the reference media and HiCrome C. auris MDR selective agar, respectively. Although C. vulturna and C. pseudohaemulonii can cause false positives, CHROMagar Candida Plus was shown to be a valuable addition to the plethora of mostly molecular methods for C. auris detection and identification.


Assuntos
Candida , Compostos Cromogênicos , Meios de Cultura , Humanos , Saccharomycetales , Especificidade da Espécie
13.
BMC Microbiol ; 21(1): 213, 2021 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-34266382

RESUMO

BACKGROUND: Burkholderia pseudomallei is the bacterial causative agent of melioidosis, a difficult disease to diagnose clinically with high mortality if not appropriately treated. Definitive diagnosis requires isolation and identification of the organism. With the increased adoption of MALDI-TOF MS for the identification of bacteria, we established a method for rapid identification of B. pseudomallei using the Vitek MS, a system that does not currently have B. pseudomallei in its in-vitro diagnostic database. RESULTS: A routine direct spotting method was employed to create spectra and SuperSpectra. An initial B. pseudomallei SuperSpectrum was created at Shoklo Malaria Research Unit (SMRU) from 17 reference isolates (46 spectra). When tested, this initial SMRU SuperSpectrum was able to identify 98.2 % (54/55) of Asian isolates, but just 46.7 % (35/75) of Australian isolates. Using spectra (430) from different reference and clinical isolates, two additional SMRU SuperSpectra were created. Using the combination of all SMRU SuperSpectra with seven existing SuperSpectra from Townsville, Australia 119 (100 %) Asian isolates and 31 (100 %) Australian isolates were correctly identified. In addition, no misidentifications were obtained when using these 11 SuperSpectra when tested with 34 isolates of other bacteria including the closely related species Burkholderia thailandensis and Burkholderia cepacia. CONCLUSIONS: This study has established a method for identification of B. pseudomallei using Vitek MS, and highlights the impact of geographical differences between strains for identification using this technique.


Assuntos
Burkholderia pseudomallei/química , Burkholderia pseudomallei/isolamento & purificação , Melioidose/diagnóstico , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Técnicas Bacteriológicas/instrumentação , Técnicas Bacteriológicas/normas , Melioidose/microbiologia , Reprodutibilidade dos Testes , Especificidade da Espécie
14.
Eur J Clin Microbiol Infect Dis ; 40(6): 1291-1301, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33486654

RESUMO

Rapid and reliable pathogen identification is compulsory to confirm ventilator-associated pneumonia (VAP) in order to initiate appropriate antibiotic treatment. In the present proof of concept, the effectiveness of rapid microorganism identification with a targeted bottom-up proteomics approach was investigated in endotracheal aspirate (ETA) samples of VAP patients. To do so, a prototype selected-reaction monitoring (SRM)-based assay was developed on a triple quadrupole mass spectrometer tracking proteotypic peptide surrogates of bacterial proteomes. Through the concurrent monitoring of 97 species-specific peptides, this preliminary assay was dimensioned to characterize the occurrence of six most frequent bacterial species responsible for over more than 65% of VAP. Assay performance was subsequently evaluated by analyzing early and regular 37 ETA samples collected from 15 patients. Twenty-five samples were above the significant threshold of 105 CFU/mL and five samples showed mixed infections (both pathogens ≥ 105 CFU/mL). The targeted proteomics assay showed 100% specificity for Acinetobacter baumannii, Escherichia coli, Haemophilus influenzae, Pseudomonas aeruginosa, Staphylococcus aureus, and Streptococcus pneumoniae. No false bacterial identification was reported and no interference was detected arising from the commensal flora. The overall species identification sensitivity was 19/25 (76%) and was higher at the patient level (84.6%). This successful proof of concept provides a rational to broaden the panel of bacteria for further clinical evaluation.


Assuntos
Bactérias/isolamento & purificação , Técnicas de Tipagem Bacteriana/métodos , Espectrometria de Massas/métodos , Pneumonia Associada à Ventilação Mecânica/diagnóstico , Pneumonia Associada à Ventilação Mecânica/microbiologia , Bactérias/química , Humanos , Intubação Intratraqueal , Respiração Artificial , Sensibilidade e Especificidade
15.
J Sep Sci ; 44(17): 3219-3228, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34212514

RESUMO

The identification of bioactive compounds in complex matrices remains a major challenge due to the lack of highly efficient and specific methods. This work developed an approach based on high-performance affinity chromatography to identify the potential antitussive compounds from Zhisou oral liquid . The main methods include the synthesis of immobilized beta2-adrenoceptor by a one-step method, the screening and identification of the potential bioactive compounds by the receptor column coupled with mass spectrometry, and the binding mechanism analysis of the compounds to the receptor by the in vivo experiment, injection amount dependent method and molecular simulation. We identified the potential bioactive compounds of Zhisou oral liquid as glycyrrhizic acid, platycodin D, tuberostemonine, and hesperidin. In vivo experiment showed that the combinational utilization of the four compounds was possible to present an equivalent antitussive effect to the formula. The docking results demonstrated that hydrogen bonds and Van der Waals forces were the main forces to drive the binding of the four compounds to beta2-adrenoceptor. We concluded that the four compounds are the effective components in Zhisou oral liquid. The proposed strategy is possible to provide an alternative for the development of highly efficient methods to pursue the bioactive compounds of complex matrices.


Assuntos
Antitussígenos/isolamento & purificação , Medicamentos de Ervas Chinesas/isolamento & purificação , Extratos Vegetais/isolamento & purificação , Receptores Adrenérgicos beta 2/química , Administração Oral , Antitussígenos/administração & dosagem , Antitussígenos/química , Cromatografia de Afinidade , Medicamentos de Ervas Chinesas/administração & dosagem , Medicamentos de Ervas Chinesas/química , Humanos , Medicina Tradicional Chinesa , Simulação de Acoplamento Molecular , Estrutura Molecular , Extratos Vegetais/administração & dosagem , Extratos Vegetais/química
16.
Int J Mol Sci ; 22(3)2021 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-33498408

RESUMO

The COVID-19 pandemic caused by the SARS-CoV-2 virus, which first emerged in December 2019, represents an ongoing global public health emergency. Here, we developed an improved and highly sensitive approach to SARS-CoV-2 detection via coupling bioluminescence in real-time (BART) and reverse-transcriptase loop-mediated amplification (RT-LAMP) protocols (RT-LAMP-BART) and was also compatible with a digital LAMP system (Rainsuit), which did not allow for real-time quantification but did, nonetheless, facilitate absolute quantification with a comparable detection limit of 104 copies/mL. Through improving RNA availability in samples to ensure the target RNA present in reaction, we additionally developed a simulated digital RT-LAMP approach using this same principle to enlarge the overall reaction volume and to achieve real-time detection with a limit of detection of 10 copies/mL, and with further improvements in the overall dynamic range of this assay system being achieved through additional optimization.


Assuntos
COVID-19/virologia , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , RNA Viral/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , SARS-CoV-2/genética , Proteínas Virais/genética , Humanos , Limite de Detecção , Medições Luminescentes/métodos , Poliproteínas/genética , RNA Viral/análise , Reação em Cadeia da Polimerase em Tempo Real/métodos , Transcrição Reversa
17.
Appl Environ Microbiol ; 86(20)2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32801186

RESUMO

Rapid and accurate identification of Arcobacter is of great importance because it is considered an emerging food- and waterborne pathogen and potential zoonotic agent. Raman spectroscopy can differentiate bacteria based on Raman scattering spectral patterns of whole cells in a fast, reagentless, and easy-to-use manner. We aimed to detect and discriminate Arcobacter bacteria at the species level using confocal micro-Raman spectroscopy (785 nm) coupled with neural networks. A total of 82 reference and field isolates of 18 Arcobacter species from clinical, environmental, and agri-food sources were included. We determined that the bacterial cultivation time and growth temperature did not significantly influence the Raman spectral reproducibility and discrimination capability. The genus Arcobacter could be successfully differentiated from the closely related genera Campylobacter and Helicobacter using principal-component analysis. For the identification of Arcobacter to the species level, an accuracy of 97.2% was achieved for all 18 Arcobacter species using Raman spectroscopy combined with a convolutional neural network (CNN). The predictive capability of Raman-CNN was further validated using an independent data set of 12 Arcobacter strains. Furthermore, a Raman spectroscopy-based fully connected artificial neural network (ANN) was constructed to determine the actual ratio of a specific Arcobacter species in a bacterial mixture ranging from 5% to 100% by biomass (regression coefficient >0.99). The application of both CNN and fully connected ANN improved the accuracy of Raman spectroscopy for bacterial species determination compared to the conventional chemometrics. This newly developed approach enables rapid identification and species determination of Arcobacter within an hour following cultivation.IMPORTANCE Rapid identification of bacterial pathogens is critical for developing an early warning system and performing epidemiological investigation. Arcobacter is an emerging foodborne pathogen and has become more important in recent decades. The incidence of Arcobacter species in the agro-ecosystem is probably underestimated mainly due to the limitation in the available detection and characterization techniques. Raman spectroscopy combined with machine learning can accurately identify Arcobacter at the species level in a rapid and reliable manner, providing a promising tool for epidemiological surveillance of this microbe in the agri-food chain. The knowledge elicited from this study has the potential to be used for routine bacterial screening and diagnostics by the government, food industry, and clinics.


Assuntos
Arcobacter/classificação , Arcobacter/isolamento & purificação , Técnicas Bacteriológicas/métodos , Redes Neurais de Computação , Análise Espectral Raman/métodos
18.
Eur J Clin Microbiol Infect Dis ; 39(10): 1855-1863, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32388696

RESUMO

Rapid identification of uropathogens is needed to determine appropriate antimicrobial therapy. This study evaluated performance of the Alfred 60 system combined with matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF MS) technology for rapid identification of uropathogens. The Alfred 60 system was used to screen urine cultures, followed by identifying the microbial pathogen in positive cultures using MALDI-TOF MS. The Alfred 60 detected positive cultures by measuring the turbidity of urine samples, which were transferred automatically to vials containing liquid medium and incubated for 3.5 h at 35 °C in the Alfred 60 system. Vials that showed growth were removed and centrifuged. The pellet was subjected to MALDI-TOF MS identification. In parallel, positive urine samples were inoculated onto agar plates for identification by conventional culture. The time required to detect positive urine cultures with Alfred 60 and identify the uropathogens with MALDI-TOF MS ranged from 15 min to 3.5 h. Among 146 positive urine samples tested, conventional cultures showed three culture groups: group 1 included 101 samples with growth of a single type of microorganism; group 2 included 34 samples with 2 types of microorganisms; and group 3 included 11 samples with ≥ 3 types of microorganisms. Direct identification by MALDI-TOF MS was concordant with 95% of the samples in group 1, 100% of the principal microorganism in group 2, but could not identify microorganisms in group 3. This combination of methods provides rapid, reliable microbial identification for most positive urine cultures.


Assuntos
Infecções Urinárias/microbiologia , Antibacterianos/uso terapêutico , Técnicas Bacteriológicas , Feminino , Hospitais Universitários , Humanos , Israel , Masculino , Pessoa de Meia-Idade , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Urinálise , Infecções Urinárias/tratamento farmacológico
19.
Eur J Clin Microbiol Infect Dis ; 39(6): 1147-1157, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32020397

RESUMO

Fast identification of pathogens directly from positive blood cultures is of highest importance to supply an adequate therapy of bloodstream infections (BSI). There are several platforms providing molecular-based identification, detection of antimicrobial resistance genes, or even a full antimicrobial susceptibility testing (AST). Two of such test systems allowing rapid diagnostics were assessed in this study: The Biofire FilmArray® and the Genmark ePlex®, both fully automated test system with a minimum of hands-on time. Overall 137 BSI episodes were included in our study and compared to conventional culture-based reference methods. The FilmArray® is using one catridge including a panel for the most common bacterial and fungal BSI pathogens as well as selected resistance markers. The ePlex® offers three different cartridges for detection of Gram-positives, Gram-negatives, and fungi resulting in a broader panel including also rare pathogens, putative contaminants, and more genetic resistance markers. The FilmArray® and ePlex® were evaluated for all 137 BSI episodes with FilmArray® detecting 119 and ePlex® detecting 128 of these. For targets on the respective panel of the system, the FilmArray® generated a sensitivity of 98.9% with 100% specificity on Gram-positive isolates. The ePlex® system generated a sensitivity of 94.7% and a specificity of 90.7% on Gram-positive isolates. In each case, the two systems performed with 100% sensitivity and specificity for the detection of Gram-negative specimens covered by each panel. In summary, both evaluated test systems showed a satisfying overall performance for fast pathogen identification and are beneficial tools for accelerating blood culture diagnostics of sepsis patients.


Assuntos
Algoritmos , Técnicas de Diagnóstico Molecular/métodos , Sepse/diagnóstico , Bactérias/genética , Bactérias/isolamento & purificação , Hemocultura , Testes Diagnósticos de Rotina , Resistência Microbiana a Medicamentos/genética , Fungos/genética , Fungos/isolamento & purificação , Humanos , Técnicas de Diagnóstico Molecular/normas , Sensibilidade e Especificidade
20.
Ann Clin Microbiol Antimicrob ; 19(1): 60, 2020 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-33298064

RESUMO

During bloodstream infections, rapid adaptation of empirical treatment according to the microorganism identified is essential to decrease mortality. The aim of the present study was to assess the microbiological performances of a new rapid version of the Sepsityper® kit (Bruker Daltonics) allowing identification of bacteria and yeast by MALDI-TOF mass spectrometry directly from positive blood cultures in 10 min and of the specific MBT-Sepsityper module for spectra analysis, designed to increase identification performance. Identification rates were determined prospectively on 350 bacterial and 29 fungal positive blood cultures, and compared to conventional diagnostic method. Our rapid diagnosis strategy (Rapid Sepsityper® protocol: one spot with and one without formic acid extraction step) combined to MBT-Sepsityper module provided 65.4%, 78.9% and 62% reliable identification to the species level of monomicrobial positive blood cultures growing respectively Gram-positive, Gram-negative bacteria or yeast. Importantly, identification rates of Gram-positive bacteria were higher in anaerobic than in aerobic bottles (77.8% vs 22.2%; p = 0.004), if formic acid extraction step was performed (60.8% vs 39.2%; p = 1.8e-6) and if specific MBT-Sepsityper module was used (76.2% vs 61.9%, p = 0.041) while no significant differences were observed for Gram-negative bacteria. For yeasts identification, formic acid extraction step improved rapid identification rate by 37.9% while the specific MBT-Sepsityper module increased overall performances by 38%, providing up to 89.7% reliable identification if associated with the standard Sepsityper® protocol. These performances, associated with a reduce turnaround time, may help to implement a rapid identification strategy of bloodstream infections in the routine workflow of microbiology laboratories.


Assuntos
Bacteriemia/diagnóstico , Bactérias/isolamento & purificação , Técnicas de Tipagem Bacteriana/métodos , Fungemia/diagnóstico , Técnicas de Tipagem Micológica/métodos , Espectrometria de Massas em Tandem/métodos , Leveduras/isolamento & purificação , Bacteriemia/microbiologia , Bactérias/química , Sangue/microbiologia , Hemocultura , Fungemia/microbiologia , Humanos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Leveduras/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA