1.
Sensors (Basel) ; 23(15)2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37571595

RESUMO

Visual measurement methods are extensively used in various fields, such as aerospace, biomedicine, agricultural production, and social life, owing to their advantages of high speed, high accuracy, and non-contact. However, traditional camera-based measurement systems, relying on the pinhole imaging model, face challenges in achieving three-dimensional measurements using a single camera by one shot. Moreover, traditional visual systems struggle to meet the requirements of high precision, efficiency, and compact size simultaneously. With the development of light field theory, the light field camera has garnered significant attention as a novel measurement method. Due to its special structure, the light field camera enables high-precision three-dimensional measurements with a single camera through only one shot. This paper presents a comprehensive overview of light field camera measurement technologies, including the imaging principles, calibration methods, reconstruction algorithms, and measurement applications. Additionally, we explored future research directions and the potential application prospects of the light field camera.

2.
Magn Reson Med ; 86(3): 1241-1255, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33783037

RESUMO

PURPOSE: The aim of the second quantitative susceptibility mapping (QSM) reconstruction challenge (Oct 2019, Seoul, Korea) was to test the accuracy of QSM dipole inversion algorithms in simulated brain data. METHODS: A two-stage design was chosen for this challenge. The participants were provided with datasets of multi-echo gradient echo images synthesized from two realistic in silico head phantoms using an MR simulator. At the first stage, participants optimized QSM reconstructions without ground truth data available to mimic the clinical setting. At the second stage, ground truth data were provided for parameter optimization. Submissions were evaluated using eight numerical metrics and visual ratings. RESULTS: A total of 98 reconstructions were submitted for stage 1 and 47 submissions for stage 2. Iterative methods had the best quantitative metric scores, followed by deep learning and direct inversion methods. Priors derived from magnitude data improved the metric scores. Algorithms based on iterative approaches and total variation (and its derivatives) produced the best overall results. The reported results and analysis pipelines have been made public to allow researchers to compare new methods to the current state of the art. CONCLUSION: The synthetic data provide a consistent framework to test the accuracy and robustness of QSM algorithms in the presence of noise, calcifications and minor voxel dephasing effects. Total Variation-based algorithms produced the best results among all metrics. Future QSM challenges should assess whether this good performance with synthetic datasets translates to more realistic scenarios, where background fields and dipole-incompatible phase contributions are included.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Algoritmos , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico
3.
J Synchrotron Radiat ; 27(Pt 2): 486-493, 2020 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-32153289

RESUMO

This paper presents a deep learning algorithm for tomographic reconstruction (GANrec). The algorithm uses a generative adversarial network (GAN) to solve the inverse of the Radon transform directly. It works for independent sinograms without additional training steps. The GAN has been developed to fit the input sinogram with the model sinogram generated from the predicted reconstruction. Good quality reconstructions can be obtained during the minimization of the fitting errors. The reconstruction is a self-training procedure based on the physics model, instead of on training data. The algorithm showed significant improvements in the reconstruction accuracy, especially for missing-wedge tomography acquired at less than 180° rotational range. It was also validated by reconstructing a missing-wedge X-ray ptychographic tomography (PXCT) data set of a macroporous zeolite particle, for which only 51 projections over 70° could be collected. The GANrec recovered the 3D pore structure with reasonable quality for further analysis. This reconstruction concept can work universally for most of the ill-posed inverse problems if the forward model is well defined, such as phase retrieval of in-line phase-contrast imaging.

4.
Magn Reson Med ; 79(3): 1661-1673, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28762243

RESUMO

PURPOSE: The aim of the 2016 quantitative susceptibility mapping (QSM) reconstruction challenge was to test the ability of various QSM algorithms to recover the underlying susceptibility from phase data faithfully. METHODS: Gradient-echo images of a healthy volunteer acquired at 3T in a single orientation with 1.06 mm isotropic resolution. A reference susceptibility map was provided, which was computed using the susceptibility tensor imaging algorithm on data acquired at 12 head orientations. Susceptibility maps calculated from the single orientation data were compared against the reference susceptibility map. Deviations were quantified using the following metrics: root mean squared error (RMSE), structure similarity index (SSIM), high-frequency error norm (HFEN), and the error in selected white and gray matter regions. RESULTS: Twenty-seven submissions were evaluated. Most of the best scoring approaches estimated the spatial frequency content in the ill-conditioned domain of the dipole kernel using compressed sensing strategies. The top 10 maps in each category had similar error metrics but substantially different visual appearance. CONCLUSION: Because QSM algorithms were optimized to minimize error metrics, the resulting susceptibility maps suffered from over-smoothing and conspicuity loss in fine features such as vessels. As such, the challenge highlighted the need for better numerical image quality criteria. Magn Reson Med 79:1661-1673, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Algoritmos , Mapeamento Encefálico/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Encéfalo/diagnóstico por imagem , Feminino , Humanos
5.
Acta Radiol ; 59(9): 1051-1059, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29254355

RESUMO

Background The image quality of digital breast tomosynthesis (DBT) volumes depends greatly on the reconstruction algorithm. Purpose To compare two DBT reconstruction algorithms used by the Siemens Mammomat Inspiration system, filtered back projection (FBP), and FBP with iterative optimizations (EMPIRE), using qualitative analysis by human readers and detection performance of machine learning algorithms. Material and Methods Visual grading analysis was performed by four readers specialized in breast imaging who scored 100 cases reconstructed with both algorithms (70 lesions). Scoring (5-point scale: 1 = poor to 5 = excellent quality) was performed on presence of noise and artifacts, visualization of skin-line and Cooper's ligaments, contrast, and image quality, and, when present, lesion visibility. In parallel, a three-dimensional deep-learning convolutional neural network (3D-CNN) was trained (n = 259 patients, 51 positives with BI-RADS 3, 4, or 5 calcifications) and tested (n = 46 patients, nine positives), separately with FBP and EMPIRE volumes, to discriminate between samples with and without calcifications. The partial area under the receiver operating characteristic curve (pAUC) of each 3D-CNN was used for comparison. Results EMPIRE reconstructions showed better contrast (3.23 vs. 3.10, P = 0.010), image quality (3.22 vs. 3.03, P < 0.001), visibility of calcifications (3.53 vs. 3.37, P = 0.053, significant for one reader), and fewer artifacts (3.26 vs. 2.97, P < 0.001). The 3D-CNN-EMPIRE had better performance than 3D-CNN-FBP (pAUC-EMPIRE = 0.880 vs. pAUC-FBP = 0.857; P < 0.001). Conclusion The new algorithm provides DBT volumes with better contrast and image quality, fewer artifacts, and improved visibility of calcifications for human observers, as well as improved detection performance with deep-learning algorithms.


Assuntos
Algoritmos , Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Artefatos , Feminino , Humanos , Aprendizado de Máquina
6.
Int J Rob Res ; 37(8): 931-952, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30739976

RESUMO

This paper presents techniques for robot-aided intraocular surgery using monocular vision in order to overcome erroneous stereo reconstruction in an intact eye. We propose a new retinal surface estimation method based on a structured-light approach. A handheld robot known as the Micron enables automatic scanning of a laser probe, creating projected beam patterns on the retinal surface. Geometric analysis of the patterns then allows planar reconstruction of the surface. To realize automated surgery in an intact eye, monocular hybrid visual servoing is accomplished through a scheme that incorporates surface reconstruction and partitioned visual servoing. We investigate the sensitivity of the estimation method according to relevant parameters and also evaluate its performance in both dry and wet conditions. The approach is validated through experiments for automated laser photocoagulation in a realistic eye phantom in vitro. Finally, we present the first demonstration of automated intraocular laser surgery in porcine eyes ex vivo.

7.
J Nucl Cardiol ; 24(3): 1036-1045, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-26758376

RESUMO

BACKGROUND: The purpose of this study was to evaluate the image quality in cardiac 18F-FDG PET using the time of flight (TOF) and/or point spread function (PSF) modeling in the iterative reconstruction (IR). METHODS: Three scanners and an anthropomorphic cardiac phantom with an insert simulating a transmural defect (TD) were used. Two sets of scans (with/without TD) were acquired, and four reconstruction schemes were considered: (1) IR; (2) IR + PSF, (3) IR + TOF, and (4) IR + TOF + PSF. LV wall thickness (FWHM), contrast between LV wall and inner chamber (C IC), and TD contrast in LV wall (C TD) were evaluated. RESULTS: Tests of the reconstruction protocols showed a decrease in FWHM from IR (13 mm) to IR + PSF (11 mm); an increase in the C IC from IR (65%) to IR + PSF (71%) and from IR + TOF (72%) to IR + TOF + PSF (77%); and an increase in the C TD from IR + PSF (72%) to IR + TOF (75%) and to IR + TOF + PSF (77%). Tests of the scanner/software combinations showed a decrease in FWHM from Gemini_TF (13 mm) to Biograph_mCT (12 mm) and to Discovery_690 (11 mm); an increase in the C IC from Gemini_TF (65%) to Biograph_mCT (73%) and to Discovery_690 (75%); and an increase in the C TD from Gemini_TF/Biograph_mCT (72%) to Discovery_690 (77%). CONCLUSION: The introduction of TOF and PSF increases image quality in cardiac 18F-FDG PET. The scanner/software combinations exhibit different performances, which should be taken into consideration when making cross comparisons.


Assuntos
Algoritmos , Técnicas de Imagem Cardíaca/métodos , Fluordesoxiglucose F18 , Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Técnicas de Imagem Cardíaca/instrumentação , Aumento da Imagem/métodos , Itália , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/instrumentação , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Software
8.
AJR Am J Roentgenol ; 208(4): 777-784, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28177655

RESUMO

OBJECTIVE: The purpose of this study was to determine whether use of iterative image reconstruction algorithms improves the accuracy of coronary CT angiography (CCTA) compared with intravascular ultrasound (IVUS) in semiautomated plaque burden assessment. MATERIALS AND METHODS: CCTA and IVUS images of seven coronary arteries were acquired ex vivo. CT images were reconstructed with filtered back projection (FBP) and adaptive statistical (ASIR) and model-based (MBIR) iterative reconstruction algorithms. Cross-sectional images of the arteries were coregistered between CCTA and IVUS in 1-mm increments. In CCTA, fully automated (without manual corrections) and semiautomated (allowing manual corrections of vessel wall boundaries) plaque burden assessments were performed for each of the reconstruction algorithms with commercially available software. In IVUS, plaque burden was measured manually. Agreement between CCTA and IVUS was determined with Pearson correlation. RESULTS: A total of 173 corresponding cross sections were included. The mean plaque burden measured with IVUS was 63.39% ± 10.63%. With CCTA and the fully automated technique, it was 54.90% ± 11.70% with FBP, 53.34% ± 13.11% with ASIR, and 55.35% ± 12.22% with MBIR. With CCTA and the semiautomated technique mean plaque burden was 54.90% ± 11.76%, 53.40% ± 12.85%, 57.09% ± 11.05%. Manual correction of the semiautomated assessments was performed in 39% of all cross sections and improved plaque burden correlation with the IVUS assessment independently of reconstruction algorithm (p < 0.0001). Furthermore, MBIR was superior to FBP and ASIR independently of assessment method (semiautomated, r = 0.59 for FBP, r = 0.52 for ASIR, r = 0.78 for MBIR, all p < 0.001; fully automated, r = 0.40 for FBP, r = 0.37 for ASIR, r = 0.53 for MBIR, all p < 0.001). CONCLUSION: For the quantification of plaque burden with CCTA, MBIR led to better correlation with IVUS than did traditional reconstruction algorithms such as FBP, independently of the use of a fully automated or semiautomated assessment approach. The highest accuracy for quantifying plaque burden with CCTA can be achieved by using MBIR data with semiautomated assessment.


Assuntos
Estenose das Carótidas/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Ultrassonografia de Intervenção/métodos , Adulto , Idoso , Algoritmos , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
IEEE Trans Nucl Sci ; 63(1): 52-60, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27127307

RESUMO

We report on the design, fabrication, and first tests of a tomographic scanner developed for proton computed tomography (pCT) of head-sized objects. After extensive preclinical testing, pCT is intended to be employed in support of proton therapy treatment planning and pre-treatment verification in patients undergoing particle-beam therapy. The scanner consists of two silicon-strip telescopes that track individual protons before and after the phantom, and a novel multistage scintillation detector that measures a combination of the residual energy and range of the proton, from which we derive the water equivalent path length (WEPL) of the protons in the scanned object. The set of WEPL values and the associated paths of protons passing through the object over a 360° angular scan are processed by an iterative, parallelizable reconstruction algorithm that runs on modern GP-GPU hardware. In order to assess the performance of the scanner, we have performed tests with 200 MeV protons from the synchrotron of the Loma Linda University Medical Center and the IBA cyclotron of the Northwestern Medicine Chicago Proton Center. Our first objective was calibration of the instrument, including tracker channel maps and alignment as well as the WEPL calibration. Then we performed the first CT scans on a series of phantoms. The very high sustained rate of data acquisition, exceeding one million protons per second, allowed a full 360° scan to be completed in less than 10 minutes, and reconstruction of a CATPHAN 404 phantom verified accurate reconstruction of the proton relative stopping power in a variety of materials.

10.
J Xray Sci Technol ; 24(5): 691-707, 2016 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-27341626

RESUMO

X-ray computed tomography is an established volume imaging technique used routinely in medical diagnosis, industrial non-destructive testing, and a wide range of scientific fields. Traditionally, computed tomography uses scanning geometries with a single axis of rotation together with reconstruction algorithms specifically designed for this setup. Recently there has however been increasing interest in more complex scanning geometries. These include so called X-ray computed laminography systems capable of imaging specimens with large lateral dimensions or large aspect ratios, neither of which are well suited to conventional CT scanning procedures. Developments throughout this field have thus been rapid, including the introduction of novel system trajectories, the application and refinement of various reconstruction methods, and the use of recently developed computational hardware and software techniques to accelerate reconstruction times. Here we examine the advances made in the last several years and consider their impact on the state of the art.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Algoritmos , Animais , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada de Feixe Cônico/tendências , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas
11.
J Xray Sci Technol ; 24(1): 23-41, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26890907

RESUMO

OBJECTIVE: The aim of this study is to investigate the validity of using the Multiple Projection Algorithm (MPA) for Breast Tomosynthesis (BT) using real projection images acquired with phantoms at a clinical setting. METHODS: The CIRS-BR3D phantom with ranging thicknesses between 3 cm and 6 cm was used for all image quality evaluations. Five sets of measurements were acquired, each comprised of a 2D mammographic image followed by a set of 25 projections within an arc length of 50°. A reconstruction algorithm based on the MPA was adapted for partial isocentric rotation using a stationary detector. For reference purposes, a Back Projection (BP) algorithm was also developed for this geometry. The performance of the algorithms was evaluated, in combination with pre-filtering of the projections, in comparative studies that involved also a comparison between tomosynthesis slices and 2D mammograms. RESULTS: Evaluation of tomosynthesis slices reconstructed with BP and MPA showed close performance for the two algorithms with no considerable differences in feature detection, size and appearance of the background tissue with the MPA running faster the overall process. Pre-filtering of the projections, led to better BT images compared to non-filtering. Increased thickness resulted in limited detection of the features of interest, especially the smaller sized ones. In these cases, the filtered BT slices allowed improved visualization due to removed superimposed tissue compared to the 2D images. The different breast-like slab arrangements in phantoms of the same thickness demonstrated a slight influence on the quality of reconstructed features. CONCLUSIONS: The MPA which had been applied previously to reconstruct tomograms from projections acquired at synchrotron facilities, is a time efficient algorithm, and is fully compliant with and can be successfully used in BT clinical systems. Compared to 2D mammography, BT shows advantage in visualizing features of small size and for increased phantom thickness or features within a dense background with superimposed structures.


Assuntos
Algoritmos , Mama/diagnóstico por imagem , Mamografia/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas
12.
J Struct Biol ; 189(2): 147-52, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25528570

RESUMO

Tomo3D is a program for fast tomographic reconstruction on multicore computers. Its high speed stems from code optimization, vectorization with Streaming SIMD Extensions (SSE), multithreading and optimization of disk access. Recently, Advanced Vector eXtensions (AVX) have been introduced in the x86 processor architecture. Compared to SSE, AVX double the number of simultaneous operations, thus pointing to a potential twofold gain in speed. However, in practice, achieving this potential is extremely difficult. Here, we provide a technical description and an assessment of the optimizations included in Tomo3D to take advantage of AVX instructions. Tomo3D 2.0 allows huge reconstructions to be calculated in standard computers in a matter of minutes. Thus, it will be a valuable tool for electron tomography studies with increasing resolution needs.


Assuntos
Imageamento Tridimensional , Software , Algoritmos , Tomografia
13.
J Microsc ; 260(2): 208-18, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26258639

RESUMO

A method for generating three-dimensional tomograms from multiple three-dimensional axial projections in STimulated Emission Depletion (STED) superresolution microscopy is introduced. Our STED< method, based on the use of a micromirror placed on top of a standard microscopic sample, is used to record a three-dimensional projection at an oblique angle in relation to the main optical axis. Combining the STED< projection with the regular STED image into a single view by tomographic reconstruction, is shown to result in a tomogram with three-to-four-fold improved apparent axial resolution. Registration of the different projections is based on the use of a mutual-information histogram similarity metric. Fusion of the projections into a single view is based on Richardson-Lucy iterative deconvolution algorithm, modified to work with multiple projections. Our tomographic reconstruction method is demonstrated to work with real biological STED superresolution images, including a data set with a limited signal-to-noise ratio (SNR); the reconstruction software (SuperTomo) and its source code will be released under BSD open-source license.

14.
J Biophotonics ; 17(3): e202300117, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38010300

RESUMO

Various reconstruction algorithms have been implemented for linear array photoacoustic imaging systems with the goal of accurately reconstructing the strength absorbers within the tissue being imaged. Since the existing algorithms have been introduced by different research groups and the context of performance evaluation was not consistent, it is difficult to make a fair comparison between them. In this study, we systematically compared the performance of 10 published image reconstruction algorithms (DAS, UBP, pDAS, DMAS, MV, EIGMV, SLSC, GSC, TR, and FD) using in-vitro phantom data. Evaluations were conducted based on lateral resolution of the reconstructed images, computational time, target detectability, and noise sensitivity. We anticipate the outcome of this study will assist researchers in selecting appropriate algorithms for their linear array PA imaging applications.


Assuntos
Técnicas Fotoacústicas , Técnicas Fotoacústicas/métodos , Diagnóstico por Imagem , Imagens de Fantasmas , Algoritmos , Processamento de Imagem Assistida por Computador/métodos
15.
Radiol Artif Intell ; 6(2): e230192, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38231025

RESUMO

Purpose To compare the image quality and diagnostic capability in detecting malignant liver tumors of low-dose CT (LDCT, 33% dose) with deep learning-based denoising (DLD) and standard-dose CT (SDCT, 100% dose) with model-based iterative reconstruction (MBIR). Materials and Methods In this prospective, multicenter, noninferiority study, individuals referred for liver CT scans were enrolled from three tertiary referral hospitals between February 2021 and August 2022. All liver CT scans were conducted using a dual-source scanner with the dose split into tubes A (67% dose) and B (33% dose). Blended images from tubes A and B were created using MBIR to produce SDCT images, whereas LDCT images used data from tube B and were reconstructed with DLD. The noise in liver images was measured and compared between imaging techniques. The diagnostic performance of each technique in detecting malignant liver tumors was evaluated by three independent radiologists using jackknife alternative free-response receiver operating characteristic analysis. Noninferiority of LDCT compared with SDCT was declared when the lower limit of the 95% CI for the difference in figure of merit (FOM) was greater than -0.10. Results A total of 296 participants (196 men, 100 women; mean age, 60.5 years ± 13.3 [SD]) were included. The mean noise level in the liver was significantly lower for LDCT (10.1) compared with SDCT (10.7) (P < .001). Diagnostic performance was assessed in 246 participants (108 malignant tumors in 90 participants). The reader-averaged FOM was 0.880 for SDCT and 0.875 for LDCT (P = .35). The difference fell within the noninferiority margin (difference, -0.005 [95% CI: -0.024, 0.012]). Conclusion Compared with SDCT with MBIR, LDCT using 33% of the standard radiation dose had reduced image noise and comparable diagnostic performance in detecting malignant liver tumors. Keywords: CT, Abdomen/GI, Liver, Comparative Studies, Diagnosis, Reconstruction Algorithms Clinical trial registration no. NCT05804799 © RSNA, 2024 Supplemental material is available for this article.


Assuntos
Carcinoma Hepatocelular , Aprendizado Profundo , Neoplasias Hepáticas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Abdome , Estudos Prospectivos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Idoso
16.
Diagnostics (Basel) ; 14(13)2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-39001321

RESUMO

Single photon emission tomography/computed tomography (SPECT/CT) is a mature imaging technology with a dynamic role in the diagnosis and monitoring of a wide array of diseases. This paper reviews the technological advances, clinical impact, and future directions of SPECT and SPECT/CT imaging. The focus of this review is on signal amplifier devices, detector materials, camera head and collimator designs, image reconstruction techniques, and quantitative methods. Bulky photomultiplier tubes (PMTs) are being replaced by position-sensitive PMTs (PSPMTs), avalanche photodiodes (APDs), and silicon PMs to achieve higher detection efficiency and improved energy resolution and spatial resolution. Most recently, new SPECT cameras have been designed for cardiac imaging. The new design involves using specialised collimators in conjunction with conventional sodium iodide detectors (NaI(Tl)) or an L-shaped camera head, which utilises semiconductor detector materials such as CdZnTe (CZT: cadmium-zinc-telluride). The clinical benefits of the new design include shorter scanning times, improved image quality, enhanced patient comfort, reduced claustrophobic effects, and decreased overall size, particularly in specialised clinical centres. These noticeable improvements are also attributed to the implementation of resolution-recovery iterative reconstructions. Immense efforts have been made to establish SPECT and SPECT/CT imaging as quantitative tools by incorporating camera-specific modelling. Moreover, this review includes clinical examples in oncology, neurology, cardiology, musculoskeletal, and infection, demonstrating the impact of these advancements on clinical practice in radiology and molecular imaging departments.

17.
Phys Eng Sci Med ; 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38625624

RESUMO

In this study, we compared the repeatability and reproducibility of radiomic features obtained from positron emission tomography (PET) images according to the reconstruction algorithm used-advanced reconstruction algorithms, such as HYPER iterative (IT), HYPER deep learning reconstruction (DLR), and HYPER deep progressive reconstruction (DPR), or traditional Ordered Subset Expectation Maximization (OSEM)-to understand the potential variations and implications of using advanced reconstruction techniques in PET-based radiomics. We used a heterogeneous phantom with acrylic spherical beads (4- or 8-mm diameter) filled with 18F. PET images were acquired and reconstructed using OSEM, IT, DLR, and DPR. Original and wavelet radiomic features were calculated using SlicerRadiomics. Radiomic feature repeatability was assessed using the Coefficient of Variance (COV) and intraclass correlation coefficient (ICC), and inter-acquisition time reproducibility was assessed using the concordance correlation coefficient (CCC). For the 4- and 8-mm diameter beads phantom, the proportion of radiomic features with a COV < 10% was equivocal or higher for the advanced reconstruction algorithm than for OSEM. ICC indicated that advanced methods generally outperformed OSEM in repeatability, except for the original features of the 8-mm beads phantom. In the inter-acquisition time reproducibility analysis, the combinations of 3 and 5 min exhibited the highest reproducibility in both phantoms, with IT and DPR showing the highest proportion of radiomic features with CCC > 0.8. Advanced reconstruction methods provided enhanced stability of radiomic features compared with OSEM, suggesting their potential for optimal image reconstruction in PET-based radiomics, offering potential benefits in clinical diagnostics and prognostics.

18.
Radiol Artif Intell ; 6(3): e230181, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38506618

RESUMO

Purpose To evaluate the effect of implementing two distinct commercially available deep learning reconstruction (DLR) algorithms on the efficiency of MRI examinations conducted in real clinical practice within an outpatient setting at a large, multicenter institution. Materials and Methods This retrospective study included 7346 examinations from 10 clinical MRI scanners analyzed during the pre- and postimplementation periods of DLR methods. Two different types of DLR methods, namely Digital Imaging and Communications in Medicine (DICOM)-based and k-space-based methods, were implemented in half of the scanners (three DICOM-based and two k-space-based), while the remaining five scanners had no DLR method implemented. Scan and room times of each examination type during the pre- and postimplementation periods were compared among the different DLR methods using the Wilcoxon test. Results The application of deep learning methods resulted in significant reductions in scan and room times for certain examination types. The DICOM-based method demonstrated up to a 53% reduction in scan times and a 41% reduction in room times for various study types. The k-space-based method demonstrated up to a 27% reduction in scan times but did not significantly reduce room times. Conclusion DLR methods were associated with reductions in scan and room times in a clinical setting, though the effects were heterogeneous depending on examination type. Thus, potential adopters should carefully evaluate their case mix to determine the impact of integrating these tools. Keywords: Deep Learning MRI Reconstruction, Reconstruction Algorithms, DICOM-based Reconstruction, k-Space-based Reconstruction © RSNA, 2024 See also the commentary by GharehMohammadi in this issue.


Assuntos
Aprendizado Profundo , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Feminino , Humanos , Masculino , Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos
19.
Eur J Radiol ; 172: 111349, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38310673

RESUMO

PURPOSE: Radiomics analysis of oncologic positron emission tomography (PET) images is an area of significant activity and potential. The reproducibility of radiomics features is an important consideration for routine clinical use. This preliminary study investigates the robustness of radiomics features in PSMA-PET images across penalized-likelihood (Q.Clear) and standard ordered subset expectation maximization (OSEM) reconstruction algorithms and their setting parameters in phantom and prostate cancer (PCa) patients. METHOD: A NEMA image quality (IQ) phantom and 8 PCa patients were selected for phantom and patient analyses, respectively. PET images were reconstructed using Q.Clear (reconstruction ß-value: 100-700, at intervals of 100 for both NEMA IQ phantom and patients) and OSEM (duration: 15sec, 30sec, 1 min, 2 min, 3 min, 4 min and 5 min for NEMA phantom and duration: 30 s, 1 min and 2 min for patients) reconstruction methods. Subsequently, 129 radiomic features were extracted from the reconstructed images. The coefficient of variation (COV) of each feature across reconstruction methods and their parameters was calculated to determine feature robustness. RESULTS: The extracted radiomics features showed a different range of variability, depending on the reconstruction algorithms and setting parameters. Specifically, 23.0 % and 53.5 % of features were found as robust against ß-value variations in Q.Clear and different durations in OSEM reconstruction algorithms, respectively. Taking into account the two algorithms and their parameters, eleven features (8.5 %) showed COV ≤ 5 % and eighteen (14 %) showed 5 % 20 %. The mean COVs of the extracted radiomics features were significantly different between the two reconstruction methods (p < 0.05) except for the phantom morphological features. CONCLUSIONS: All radiomics features were affected by reconstruction methods and parameters, but features with small or very small variations are considered better candidates for reproducible quantification of either tumor or metastatic tissues in clinical trials. There is a need for standardization before the implementation of PET radiomics in clinical practice.


Assuntos
Processamento de Imagem Assistida por Computador , Radiômica , Masculino , Humanos , Reprodutibilidade dos Testes , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Algoritmos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada
20.
Diagnostics (Basel) ; 14(7)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38611645

RESUMO

Spectral CT represents a novel imaging approach that can noninvasively visualize, quantify, and characterize many musculoskeletal pathologies. This modality has revolutionized the field of radiology by capturing CT attenuation data across multiple energy levels and offering superior tissue characterization while potentially minimizing radiation exposure compared to traditional enhanced CT scans. Despite MRI being the preferred imaging method for many musculoskeletal conditions, it is not viable for some patients. Moreover, this technique is time-consuming, costly, and has limited availability in many healthcare settings. Thus, spectral CT has a considerable role in improving the diagnosis, characterization, and treatment of gout, inflammatory arthropathies, degenerative disc disease, osteoporosis, occult fractures, malignancies, ligamentous injuries, and other bone-marrow pathologies. This comprehensive review will delve into the diverse capabilities of dual-energy CT, a subset of spectral CT, in addressing these musculoskeletal conditions and explore potential future avenues for its integration into clinical practice.