Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 144
Filtrar
1.
J Sleep Res ; : e14210, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38577714

RESUMO

This study evaluates the performance of two major artificial intelligence-based tools (ChatGPT-4 and Google Bard) in debunking sleep-related myths. More in detail, the present research assessed 20 sleep misconceptions using a 5-point Likert scale for falseness and public health significance, comparing responses of artificial intelligence tools with expert opinions. The results indicated that Google Bard correctly identified 19 out of 20 statements as false (95.0% accuracy), not differing from ChatGPT-4 (85.0% accuracy, Fisher's exact test p = 0.615). Google Bard's ratings of the falseness of the sleep misconceptions averaged 4.25 ± 0.70, showing a moderately negative skewness (-0.42) and kurtosis (-0.83), and suggesting a distribution with fewer extreme values compared with ChatGPT-4. In assessing public health significance, Google Bard's mean score was 2.4 ± 0.80, with skewness and kurtosis of 0.36 and -0.07, respectively, indicating a more normal distribution compared with ChatGPT-4. The inter-rater agreement between Google Bard and sleep experts had an intra-class correlation coefficient of 0.58 for falseness and 0.69 for public health significance, showing moderate alignment (p = 0.065 and p = 0.014, respectively). Text-mining analysis revealed Google Bard's focus on practical advice, while ChatGPT-4 concentrated on theoretical aspects of sleep. The readability analysis suggested Google Bard's responses were more accessible, aligning with 8th-grade level material, versus ChatGPT-4's 12th-grade level complexity. The study demonstrates the potential of artificial intelligence in public health education, especially in sleep health, and underscores the importance of accurate, reliable artificial intelligence-generated information, calling for further collaboration between artificial intelligence developers, sleep health professionals and educators to enhance the effectiveness of sleep health promotion.

2.
J Ultrasound Med ; 43(1): 33-43, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37732906

RESUMO

OBJECTIVES: Non-compressive strain elastography has been proposed as a novel quantitative imaging biomarker for assessing the structure and function of the cervix. The current study aims to assess the repeatability, and intra- and inter-observer reliability of transvaginal non-compressive cervical strain elastography in a clinical setting. METHODS: We conducted a dual-phase single-center prospective feasibility study of singleton gestations >16-weeks gestation that required a clinically-indicated transvaginal ultrasound. Each study participant, n = 43 in phase 1 and n = 13 in phase 2, had elastography performed by two trained observers that each performed multiple image acquisitions. We performed a multivariable regression to adjust for changes in clinical characteristics between study phases and calculated the repeatability coefficients, limits of agreement, and intraclass correlations for each quantitative elastography parameter. We compared quantitative elastography parameters to cervical length measurements, acquired from the same images. RESULTS: The repeatability coefficients and percent limits of agreement were wide for all of the quantitative elastography parameters, demonstrating poor repeatability. Intraclass correlation coefficients were poor-moderate for both intra-observer (0.31-0.77) and inter-observer reliability (0.35-0.77) in both study phases, while cervical length showed excellent reliability with intraclass correlations consistently >0.90. CONCLUSIONS: Non-compressive transvaginal strain cervical elastography did not demonstrate adequate repeatability or reliability. Our results highlight the importance of rigorously assessing novel quantitative imaging biomarkers before clinical application.


Assuntos
Colo do Útero , Técnicas de Imagem por Elasticidade , Gravidez , Feminino , Humanos , Colo do Útero/diagnóstico por imagem , Estudos Prospectivos , Técnicas de Imagem por Elasticidade/métodos , Reprodutibilidade dos Testes , Medida do Comprimento Cervical , Variações Dependentes do Observador
3.
Risk Anal ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38653954

RESUMO

The analysis of system reliability has often benefited from graphical tools such as fault trees and Bayesian networks. In this article, instead of conventional graphical tools, we apply a probabilistic graphical model called the chain event graph (CEG) to represent the failures and processes of deterioration of a system. The CEG is derived from an event tree and can flexibly represent the unfolding of asymmetric processes. For this application, we need to define a new class of formal intervention we call remedial to model the causal effects of remedial maintenance. This fixes the root causes of a failure and returns the status of the system to as good as new. We demonstrate that the semantics of the CEG are rich enough to express this novel type of intervention. Furthermore, through the bespoke causal algebras, the CEG provides a transparent framework with which to guide and express the rationale behind predictive inferences about the effects of various types of remedial intervention. A backdoor theorem is adapted to apply to these interventions to help discover when a system is only partially observed.

4.
Cogn Behav Ther ; : 1-23, 2024 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-39263846

RESUMO

Researchers and clinicians are becoming increasingly aware of the importance of assessing positive functioning to inform clinical outcomes. This paper evaluates the Questionnaire on Well-Being (QWB, available for free https://doi.org/10.17605/OSF.IO/GSC3R), a clinically informed instrument that assesses subjective well-being, across two studies. Study One, consisting of treatment-seeking individuals in an assertiveness training sample (n = 495), explored the factorial structure of the QWB, assessed the four-week test-retest reliability, criterion-related validity, and identified a preliminary cutoff point for the QWB with clinical significance. Study Two, including participants from the general public (n = 1561), confirmed the factorial structure of the QWB and further evaluated criterion-related validity. The results provided support for a unidimensional structure for the QWB. Furthermore, the QWB exhibited excellent internal reliability (Cronbach's alpha = 0.93 and 0.94 in Study One and Two, respectively), high test-retest reliability (ICC3 = .50 at a four-week follow-up in Study One), and appropriate criterion-related validity demonstrating positive correlations with positive affect and negative correlations with psychopathology. Finally, a cutoff point on the QWB below 50 was associated with marked psychopathology. These findings provide preliminary support for the usage of the QWB in clinical and non-clinical settings, establishing the QWB as a reliable indicator of subjective well-being.

5.
Philos Trans A Math Phys Eng Sci ; 381(2260): 20220384, 2023 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-37742710

RESUMO

For the fatigue reliability analysis of aeroengine blade-disc systems, the traditional direct integral modelling methods or separate independent modelling methods will lead to low computational efficiency or accuracy. In this work, a physics-informed ensemble learning (PIEL) method is proposed, i.e. firstly, based on the physical characteristics of blade-disc systems, the complex multi-component reliability analysis is split into a series of single-component reliability analyses; moreover, the PIEL model is established by introducing the mapping of multiple constitutive responses and the multi-material physical characteristics into the ensemble learning; finally, the PIEL-based system reliability framework is established by quantifying the failure correlation with the Copula function. The reliability analysis of a typical aeroengine high-pressure turbine blade-disc system is regarded as an example to verify the effectiveness of the proposed method. Compared with the direct Monte Carlo, support vector regression, neural network, ensemble learning and physics-informed neural network, the proposed method exhibits the highest computing accuracy and efficiency, and is validated to be an efficient method for the reliability analysis of blade-disc systems. The current work can provide a novel insight for physics-informed modelling and fatigue reliability analyses. This article is part of the theme issue 'Physics-informed machine learning and its structural integrity applications (Part 1)'.

6.
Philos Trans A Math Phys Eng Sci ; 381(2260): 20220385, 2023 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-37742713

RESUMO

To effectively perform the reliability analysis of the flap deflection angle, the reliability analysis framework is developed by introducing fault logic and a data-driven model. Herein, the fault logic analysis is used to study the fault mechanism and filter out the characteristic fault parameters that can be used to collect input data for data-driven modelling; the data-driven modelling is employed to establish a reliability analysis model with a small amount of input data. Under this proposed framework, the improved dung beetle optimization algorithm for back propagation (IDBO-BP) method is developed to perform the reliability modelling of the flap deflection angle. To validate the effectiveness of the proposed framework, we study the fault logic of flap symmetry and establish a surrogate model of flap deflection based on the fault parameters and the IDBO-BP algorithm. According to the predicted results of the flap deflection angle, the reliability model based on the fault mechanism can reflect the actual flap motion. At the same time, the proposed IDBO-BP algorithm has excellent modelling and simulation property by comparing with other optimization algorithms. Thus, the efforts of this study provide a new solution to the problem of reliable analysis with uncertain fault parameters. This article is part of the theme issue 'Physics-informed machine learning and its structural integrity applications (Part 1)'.

7.
J Environ Manage ; 345: 118696, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37549639

RESUMO

Invasive alien species have widespread impacts on native biodiversity and ecosystem services. Since the number of introductions worldwide is continuously rising, it is essential to prevent the entry, establishment and spread of new alien species through a systematic examination of future potential threats. Applying a three-step horizon scanning consensus method, we evaluated non-established alien species that could potentially arrive, establish and cause major ecological impact in Spain within the next 10 years. Overall, we identified 47 species with a very high risk (e.g. Oreochromis niloticus, Popillia japonica, Hemidactylus frenatus, Crassula helmsii or Halophila stipulacea), 61 with high risk, 93 with moderate risk, and 732 species with low risk. Many of the species categorized as very high or high risk to Spanish biodiversity are either already present in Europe and neighbouring countries or have a long invasive history elsewhere. This study provides an updated list of potential invasive alien species useful for prioritizing efforts and resources against their introduction. Compared to previous horizon scanning exercises in Spain, the current study screens potential invaders from a wider range of terrestrial, freshwater, and marine organisms, and can serve as a basis for more comprehensive risk analyses to improve management and increase the efficiency of the early warning and rapid response framework for invasive alien species. We also stress the usefulness of measuring agreement and consistency as two different properties of the reliability of expert scores, in order to more easily elaborate consensus ranked lists of potential invasive alien species.


Assuntos
Ecossistema , Espécies Introduzidas , Espanha , Reprodutibilidade dos Testes , Biodiversidade
8.
J Nucl Cardiol ; 29(5): 2199-2209, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34036529

RESUMO

INTRODUCTION AND BACKGROUND: The polarity status is one of the important items of specifications of trigger signal from cardiac trigger monitors with two options, either positive or negative. Some systems allow the user to set the polarity of trigger signal before imaging. Efforts should be made to set the polarity status according to the recommendations provided by the manufacturers. In case of inappropriate selection, changes in computation of end-systolic and end-diastolic volumes as well as ejection fraction may occur. OBJECTIVE: To investigate the effect of the polarity status of trigger signals in synchronization process during 8- and 16-frame gated SPECT imaging on the systolic and diastolic parameters of LV function. METHODS: Thirty-four patients referred for a myocardial perfusion SPECT were consecutively included in the study. The rest scan for each patient was performed with 8- and 16-frame gating simultaneously with positive trigger signal set by the operator in a cardiac trigger monitor and then repeated after manual selection of negative polarity. In total, the 4 imaging modes acquired were 8-frame/positive-trigger, 16-frame/positive-trigger, 8-frame/negative-trigger, and 16-frame/negative-trigger. All SPECT images were reconstructed and processed with the same values of parameters. Systolic and diastolic indices of LV function were derived in QGS of the Cedars-Sinai software and then were compared using various statistical tests, and a reliability analysis was also performed. RESULTS: The age of patients recruited in the study was 58.41 ± 8.94, and 16 (47.1%) males and 18 (52.9%) females. All the correlation coefficients between corresponding parameters in positive and negative trigger signals were statistically significant. The difference between the parameters of systolic function including EF, EDV, and ESV in positive and negative trigger signals was statistically significant in paired sample t test. Likewise, a statistically significant difference was also found between mean phase angle in scans with positive and negative trigger signals by a phase difference of 147.91 (41.0% of an average cardiac cycle) and 149 (41.3% of an average cardiac cycle) degrees in 8- and 16-frame gating modes, respectively. Strong agreement (according to high values of intra-class correlation coefficient) was found for all four pairs. According to Bland-Altman results, an offset of about 3 percentage units was found, both between imaging in 8-frame gating compared to 16-frame gating, higher value in favor of 16-frame gating, and also between imaging with positive polarity trigger compared to negative-polarity trigger, again higher value in favor of positive-polarity triggering. CONCLUSION: The status of the polarity of trigger signals or similar CTM-camera delays in synchronization process during 8- and 16-frame gated SPECT imaging can be considered as one of the factors that may influence systolic and diastolic indices of LV function.


Assuntos
Tomografia Computadorizada de Emissão de Fóton Único , Função Ventricular Esquerda , Eletrocardiografia , Feminino , Imagem do Acúmulo Cardíaco de Comporta/métodos , Humanos , Masculino , Perfusão , Reprodutibilidade dos Testes , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único/métodos
9.
Sensors (Basel) ; 22(4)2022 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-35214480

RESUMO

Fatigue of steel bridges is a major concern for bridge engineers. Previous fatigue-based weight-limiting method of steel bridges is founded on the Palmgren-Miner's rule and S-N curves, which overlook the effect of existing cracks on the fatigue life of in-service steel bridges. In the present study, based on the theory of linear elastic fracture mechanics, a framework combining the artificial neural networks and Monte Carlo simulations is proposed to analyze the fatigue reliability of steel bridges with the effects of cracks and truck weight limits considered. Using the framework, a new method of setting the gross vehicle weight limit for in-service steel bridges with cracks is proposed. The influences of four key parameters, including the average daily truck traffic, the gross vehicle weight limit, the violation rate, and the detected crack size, on the fatigue reliability of a steel bridge are analyzed quantitatively with the new framework. Results show that the suggested framework can enhance the fatigue reliability assessment process in terms of accuracy and efficiency. The method of setting gross vehicle weight limits can effectively control the fatigue failure probability to be within 2.3% according to the desired remaining service time and the detected crack size.

10.
Entropy (Basel) ; 24(9)2022 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-36141095

RESUMO

Uncertainties are normally unavoidable in engineering practice, which should be taken into account in the structural design and optimization so as to reduce the relevant risks. Yet, the probabilistic models of the uncertainties are often unavailable in the problems due to the lack of samples, and the precision of the conventional non-probabilistic models are not satisfactory when the samples are of multi-cluster distribution. In view of this, an improved method by using a non-probabilistic multi-cluster ellipsoidal model (multi-CEM) for the critical structural reliability analysis is proposed in this paper, which describes the samples in a more accurate and compact way and helps to acquire more satisfactory reliability analysis results. Firstly, a Gaussian mixture model (GMM) is built for the multi-cluster samples with performing expectation maximization (EM) algorithm, based on which the multi-CEM can be constructed. In the structural reliability analysis, two cases, respectively, considering whether the components of the multi-CEM are intersected or not are researched in detail. The non-probabilistic reliability (NPR) indexes for each component of the multi-CEM are computed using the Hasofer-Lind-Rackwitz-Fiessler (HL-RF) algorithm, and then the multidimensional volume ratios of the safe domain to the whole uncertainty domain are computed based on these indexes, indicating the structural NPR. In the end, two numerical examples and a practical application are conducted and analyzed to testify the effectiveness of the method.

11.
Int Endod J ; 2021 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-33969501

RESUMO

AIM: To document satisfaction with root canal treatment procedures and outcomes among patients treated at Swedish public dental clinics. METHOD: The original material comprised 243 patients who began root canal treatment (RCT) at 20 public dental clinics in the county of Västra Götaland, Sweden. One to three years later, 236 (97.1%) were posted a questionnaire of eight items, rating patient perceptions of RCT-completion, present pain intensity and satisfaction with the RCT. To evaluate the reliability of the original responses, the first 50 respondents were mailed a follow-up questionnaire. Both descriptive and analytical statistics were used to compare respondents and non-respondents and tooth groups. RESULTS: One hundred and fifty-nine patients (67.4%) responded: 86 (54.1%) women and 73 (45.9%) men. The mean age 52.5 years, was higher than for non-respondents (P<0.001). A completed root filling was registered for the majority of the teeth (n = 112, 70.9%), but significantly fewer molars had been completed (n = 46, 59.7%, P = 0.02). Fifty percent (n = 59) of the patients reported current pain, mostly mild in intensity (n = 45, 38.1%). One hundred and twenty-three patients (80.9%) recalled experiencing pain during RCT. The highest satisfaction was registered for the item 'chewing ability' (mean = 1.6, SD = 1.9). The majority of patients (n = 114, 75.0%) stated that in retrospect they would still have chosen RCT. However, these patients belonged to the group which either registered the tooth as still present, or had not experienced much discomfort during or after RCT. Forty-four patients (88.0%) responded to the second questionnaire. The reliability of the responses was good. In summary, one to 3 years after beginning RCT at a public dental clinic, patient satisfaction was high, even though every fourth molar had been extracted or treatment had not been completed and half the patients reported persistent pain. The reliability of the patients' responses was considered to be good. CONCLUSIONS: The results indicate a need for further clinical observational studies of RCTs undertaken in general dental practice, with special reference to patient-centred outcomes.

12.
Sensors (Basel) ; 21(24)2021 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-34960521

RESUMO

The Time-Sensitive Networking (TSN) Task Group has standardised different mechanisms to provide Ethernet with hard real-time guarantees and reliability in layer 2 of the network architecture. Specifically, TSN proposes using space redundancy to increase the reliability of Ethernet networks, but using space redundancy to tolerate temporary faults is not a cost-effective solution. For this reason, we propose to use time redundancy to tolerate temporary faults in the links of TSN-based networks. Specifically, in previous works we proposed the Proactive Transmission of Replicated Frames (PTRF) mechanism to tolerate temporary faults in the links. Now, in this work we present a series of models of TSN and PTRF developed using PRISM, a probabilistic model checker that can be used to evaluate the reliability of systems. After that, we carry out a parametric sensitivity analysis of the reliability achievable by TSN and PTRF and we show that we can increase the reliability of TSN-based networks using PTRF to tolerate temporary faults in the links of TSN networks. This is the first work that presents a quantitative analysis of the reliability of TSN networks.


Assuntos
Redes Locais , Redes Locais/normas , Reprodutibilidade dos Testes
13.
Neuroimage ; 218: 116932, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32416226

RESUMO

BACKGROUND: The amygdala and the hippocampus are two limbic structures that play a critical role in cognition and behavior, however their manual segmentation and that of their smaller nuclei/subfields in multicenter datasets is time consuming and difficult due to the low contrast of standard MRI. Here, we assessed the reliability of the automated segmentation of amygdalar nuclei and hippocampal subfields across sites and vendors using FreeSurfer in two independent cohorts of older and younger healthy adults. METHODS: Sixty-five healthy older (cohort 1) and 68 younger subjects (cohort 2), from the PharmaCog and CoRR consortia, underwent repeated 3D-T1 MRI (interval 1-90 days). Segmentation was performed using FreeSurfer v6.0. Reliability was assessed using volume reproducibility error (ε) and spatial overlapping coefficient (DICE) between test and retest session. RESULTS: Significant MRI site and vendor effects (p â€‹< â€‹.05) were found in a few subfields/nuclei for the ε, while extensive effects were found for the DICE score of most subfields/nuclei. Reliability was strongly influenced by volume, as ε correlated negatively and DICE correlated positively with volume size of structures (absolute value of Spearman's r correlations >0.43, p â€‹< â€‹1.39E-36). In particular, volumes larger than 200 â€‹mm3 (for amygdalar nuclei) and 300 â€‹mm3 (for hippocampal subfields, except for molecular layer) had the best test-retest reproducibility (ε â€‹< â€‹5% and DICE â€‹> â€‹0.80). CONCLUSION: Our results support the use of volumetric measures of larger amygdalar nuclei and hippocampal subfields in multisite MRI studies. These measures could be useful for disease tracking and assessment of efficacy in drug trials.


Assuntos
Tonsila do Cerebelo/anatomia & histologia , Hipocampo/anatomia & histologia , Processamento de Imagem Assistida por Computador/normas , Neuroimagem/normas , Software , Adulto , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Neuroimagem/métodos , Reprodutibilidade dos Testes
14.
Surg Endosc ; 34(4): 1492-1508, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31953728

RESUMO

BACKGROUND: Both morbidity and mortality data (MMD) and learning curves (LCs) do not provide information on the nature of intraoperative errors and their mechanisms when these adversely impact on patient outcome. OCHRA was developed specifically to address the unmet surgical need for an objective assessment technique of the quality of technical execution of operations at individual operator level. The aim of this systematic review was to review of OCHRA as a method of objective assessment of surgical operative performance. METHODS: Systematic review based on searching 4 databases for articles published from January 1998 to January 2019. The review complies with Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines and includes original publications on surgical task performance based on technical errors during operations across several surgical specialties. RESULTS: Only 26 published studies met the search criteria, indicating that the uptake of OCHRA during the study period has been low. In 31% of reported studies, the operations were performed by fully qualified consultant/attending surgeons and by surgical trainees in 69% in approved training programs. OCHRA identified 7869 consequential errors (CE) during the conduct of 719 clinical operations (mean = 11 CEs). It also identified 'hazard zones' of operations and proficiency-gain curves (P-GCs) that confirm attainment of persistent competent execution of specific operations by individual trainee surgeons. P-GCs are both surgeon and operation specific. CONCLUSIONS: Increased OCHRA use has the potential to improve patient outcome after surgery, but this is a contingent progress towards automatic assessment of unedited videos of operations. The low uptake of OCHRA is attributed to its labor-intensive nature involving human factors (cognitive engineering) expertise. Aside from faster and more objective peer-based assessment, this development should accelerate increased clinical uptake and use of the technique in both routine surgical practice and surgical training.


Assuntos
Competência Clínica/normas , Cirurgia Geral/normas , Análise de Causa Fundamental/métodos , Análise e Desempenho de Tarefas , Humanos , Erros Médicos/estatística & dados numéricos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Medição de Risco/métodos , Gravação de Videoteipe
15.
BMC Public Health ; 20(1): 1595, 2020 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-33092568

RESUMO

BACKGROUND: Since the time of declaration of global pandemic of COVID-19 by World Health Organization (WHO), falsified hand sanitizers surfaced regularly in markets, posing possible harm to public due to unlisted inclusion of methanol. The current research is an attempt to develop and validate a tool to document falsified hand sanitizer in the UAE community. METHOD: A descriptive cross-sectional community-based study was conducted among 1280 randomly selected participants. Respondents were sent a web-based electronic link to the survey via email. Content validity, factor analyses and known group validity were used to develop and validate a new scale to identify falsified hand sanitizer. Test-retest reliability, internal consistency, item internal consistency (IIC), and intraclass correlation coefficients (ICCs) were used to assess the reliability of the scale. SPSS version 24 was used to conduct data analysis. RESULTS: A total of 1280 participants were enrolled in the study. The content validity index (CVI) was 0.83 with the final scale of 12 items. The Kaiser-Meyer-Olkin (KMO) value was 0.788, with the Bartlett test of sphericity achieving statistical significance (p < 0.001). Our factor analysis revealed a 3-component model. The 3-factor solution was confirmed by PCFA analysis and had associations with good fit values. The PCFA for NFI was 0.970, CFI 0.978, and TLI 0.967. All values were in excess of 0.95, with RMSEA values below 0.06 at 0.03; all of these values indicated a good model fit. The Cronbach's alpha was good overall (0.867). All factors had a Cronbach's alpha value in excess of 0.70. The instrument demonstrated that every item met the IIC correlation standard ≥0.40. The scale displayed good overall ICC statistics of 0.867 (95% CI 0.856-0.877) with statistical significance (p < 0.001). The scale's test-retest reliability was assessed through correlation of the falsified hand sanitizer identification score of respondents at the two time points. The test-retest correlation coefficient was 0.770 (p value < 0.01). Participants with post-graduate education were more likely to identify the falsified hand sanitizer compared to those with high school education. (p < 0.001). CONCLUSIONS: This study developed and validated a new scale for the measurement of falsified hand sanitizer. This is expected to improve and promote collaboration between the health regulators and the public and hereby encourage customer satisfaction and participation.


Assuntos
Fraude , Higienizadores de Mão/normas , Inquéritos e Questionários , Adolescente , Adulto , COVID-19 , Infecções por Coronavirus/epidemiologia , Estudos Transversais , Análise Fatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , Projetos Piloto , Pneumonia Viral/epidemiologia , Saúde Pública/legislação & jurisprudência , Reprodutibilidade dos Testes , Emirados Árabes Unidos/epidemiologia , Adulto Jovem
16.
Risk Anal ; 40(6): 1183-1211, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32147863

RESUMO

This article presents a discourse on the incorporation of organizational factors into probabilistic risk assessment (PRA)/probabilistic safety assessment (PSA), a topic of debate since the 1980s that has spurred discussions among industry, regulatory agencies, and the research community. The main contributions of this article include (1) identifying the four key open questions associated with this topic; (2) framing ongoing debates by considering differing perspectives around each question; (3) offering a categorical review of existing studies on this topic to justify the selection of each question and to analyze the challenges related to each perspective; and (4) highlighting the directions of research required to reach a final resolution for each question. The four key questions are: (I) How significant is the contribution of organizational factors to accidents and incidents? (II) How critical, with respect to improving risk assessment, is the explicit incorporation of organizational factors into PRA? (III) What theoretical bases are needed for explicit incorporation of organizational factors into PRA? (IV) What methodological bases are needed for the explicit incorporation of organizational factors into PRA? Questions I and II mainly analyze PRA literature from the nuclear domain. For Questions III and IV, a broader review and categorization is conducted of those existing cross-disciplinary studies that have evaluated the effects of organizational factors on safety (not solely PRA-based) to shed more light on future research needs.

17.
J Environ Manage ; 255: 109881, 2020 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-31778870

RESUMO

Pollutant concentrations in influents into constructed wetlands (CWs) are highly fluctuating and may vary over several orders of magnitude, leading to large uncertainties in removal performance assessment when using pollutant concentrations in the influent and effluent directly. Incorporating a probabilistic approach into removal performance assessment and needed area estimation of CWs could advantage decision making regarding wastewater treatment and engineering applications. A series of three-stage surface-flow CWs (SFCWs) were constructed for treating ammonium-rich swine wastewater. The surface removal rate and removal efficiency of ammonium nitrogen in the SFCWs using the probabilistic approach were 0.27-3.23 g m-2 d-1 and 43.0-99.9% (95% confidence interval (CI)), which were consistent with the deterministic approach (95% CI: 0.24-3.18 g m-2 d-1 and 70.4-99.9%). The needed SFCW area was estimated as 6.6 (95% CI: 1.4-17.8) to 29.7 (95% CI: 6.4-80.1) m2 for required removal efficiency from 40% to 90% for 0.18 m3 d-1 swine wastewater with different strengthens. For specific removal efficiency of 90%, the needed CW areas was 13.9 (95%CI: 4.9-42.7), 25.1 (95%CI: 5.9-66.0), 33.5 (95%CI: 13.5-87.1), and 40.8 (95%CI: 16.2-89.4) m2 for influent ammonium loading rate of 0.18-2.7, 2.7-14.4, 14.4-36, and 36-60 g d-1, respectively. The first-order removal constant of ammonium nitrogen decreased logarithmically with increasing influent and effluent concentration/loading rate in the SFCW units (p < 0.001), which was responsible for the needed SFCW areas covering a wide range. The reliability analysis confirmed the results from the probabilistic approach were appropriate. The present study shed new lights on the performance evaluation and design of CWs for treating wastewater with highly-fluctuating concentrations using a probabilistic approach.


Assuntos
Nitrogênio , Áreas Alagadas , Animais , Desnitrificação , Reprodutibilidade dos Testes , Suínos , Eliminação de Resíduos Líquidos , Águas Residuárias
18.
Clin Oral Investig ; 23(6): 2733-2741, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30361794

RESUMO

OBJECTIVES: To evaluate the effect of bioactive glass 45S5 (BG) in experimental composites on flexural strength (FS), flexural modulus (FM), modulus of resilience (MR), and material reliability after artificial aging in water for 1, 7, and 30 days, and an additional accelerated aging for 3 days in a 75 vol% ethanol-water solution. MATERIALS AND METHODS: Five experimental light-curable composites were prepared with 0-40 wt% of BG and a total filler load of 70 wt%. The resinous matrix was Bis-GMA/TEGDMA in 60:40 by weight. Mechanical properties were evaluated using a three-point bending test (ISO/DIN 4049:1998) with n = 20. Weibull statistics were used to assess material reliability. Additionally, the degree of conversion (DC) was assessed 24 h post-cure using FT-Raman spectroscopy. RESULTS: FS and FM decreased linearly as the amount of BG was increased. The ISO 4049 requirement for a minimum FS of 80 MPa was fulfilled in experimental composites with up to 20 wt% of BG. Degradation of FS and FM with artificial aging was more extensive in materials with higher BG amounts. MR decreased as a function of BG amount and artificial aging. Material reliability (Weibull modulus) was stable through aging for composites with up to 10 wt% of BG. DC was negatively influenced by the BG amount and ranged from 64 to 81%. CONCLUSION: Increasing the amount of unsilanized BG fillers from 0 to 40 wt% resulted in a progressive decline in mechanical properties and a more extensive degradation during artificial aging. CLINICAL RELEVANCE: Bioactive fillers diminished the mechanical properties in a dose-dependent manner.


Assuntos
Cerâmica , Resinas Compostas , Materiais Dentários , Etanol , Vidro , Água , Teste de Materiais , Metacrilatos , Maleabilidade , Reprodutibilidade dos Testes , Propriedades de Superfície
19.
J Appl Biomech ; 35(6): 393­400, 2019 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-31629341

RESUMO

Accurate and reliable detection of the onset of gait initiation is essential for the correct assessment of gait. Thus, this study was aimed at evaluation of the reliability and accuracy of 3 different center of pressure-based gait onset detection algorithms: A displacement baseline-based algorithm (method 1), a velocity baseline-based algorithm (method 2), and a velocity extrema-based algorithm (method 3). The center of pressure signal was obtained during 10 gait initiation trials from 16 healthy participants and 3 participants with Parkinson's disease. Intrasession and absolute reliability of each algorithm was assessed using the intraclass correlation coefficient and the coefficient of variation of center of pressure displacement during the postural phase of gait initiation. The accuracy was evaluated using the time error of the detected onset by each algorithm relative to that of visual inspection. The authors' results revealed that although all 3 algorithms had high to very high intrasession reliabilities in both healthy subjects and subjects with Parkinson's disease, methods 2 and 3 showed significantly better absolute reliability than method 1 in healthy controls (P = .001). Furthermore, method 2 outperformed the other 2 algorithms in both healthy subjects and subjects with Parkinson's disease with an overall accuracy of 0.80. Based on these results, the authors recommend using method 2 for accurate and reliable gait onset detection.

20.
Entropy (Basel) ; 21(4)2019 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-33267053

RESUMO

In this paper, we introduced a new three-parameter probability model called Poisson generalized half logistic (PoiGHL). The new model possesses an increasing, decreasing, unimodal and bathtub failure rates depending on the parameters. The relationship of PoiGHL with the exponentiated Weibull Poisson (EWP), Poisson exponentiated Erlang-truncated exponential (PEETE), and Poisson generalized Gompertz (PGG) model is discussed. We also characterized the PoiGHL sub model, i.e the half logistic Poisson (HLP), based on certain functions of a random variable by truncated moments. Several mathematical and statistical properties of the PoiGHL are investigated such as moments, mean deviations, Bonferroni and Lorenz curves, order statistics, Shannon and Renyi entropy, Kullback-Leibler divergence, moments of residual life, and probability weighted moments. Estimation of the model parameters was achieved by maximum likelihood technique and assessed by simulation studies. The stress-strength analysis was discussed in detail based on maximum likelihood estimation (MLE), we derived the asymptotic confidence interval of R = P ( X 1 < X 2 ) based on the MLEs, and examine by simulation studies. In three applications to real data set PoiGHL provided better fit and outperform some other popular distributions. In the stress-strength parameter estimation PoiGHL model illustrated as a reliable choice in reliability analysis as shown using two real data set.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA