1.
J Cardiovasc Electrophysiol ; 35(6): 1156-1164, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38566599

RESUMO

INTRODUCTION: Left atrial (LA) low voltage areas (LVA) are a controversial target in atrial fibrillation ablation procedures. However, LVA and LA volume are good predictors of arrhythmia recurrence in ablation-naïve patients. Their predictive value in progressively diseased pre-ablated atria is uncertain. METHODS: Consecutive patients with recurrent atrial fibrillation (AF) or atrial tachycardia (AT), who were scheduled for repeat LA ablation, were enrolled in the prospective Bernau ablation registry between 2016 and 2020. All patients received a complete LA ultrahigh-density map before ablation. Maps were analyzed for LA size, LVA percentage and distribution. The predictive value of demographic, anatomic, and mapping variables on AF recurrence was analyzed. RESULTS: 160 patients (50.6% male, 1.3 pre-ablations, 60% persistent AF) with complete LA voltage maps were included. Mean follow-up time was 16 ± 11 months. Mean recorded electrograms (EGMs) per map were 9754 ± 5808, mean LA volume was 176.1 ± 35.9 ml and mean rate of LVAs <0.5 mV was 30.6% ± 23.1%. During follow-up recurrence rate of AF or AT >30 s was 55.6%. Patients with recurrence had a significant higher percentage of LVAs (40.0% vs. 18.8%, p < .001) but no relevant difference in LA volume (172 vs. 178 mL, p = .299). ROC curves revealed LVA as a good predictor for recurrence (AUC = 0.79, p < .001) and a cut-off of 22% LVAs with highest sensitivity (73.0%) and specificity (71.8%). Based on this cut off, event free survival was significantly higher in the Low LVA group (p < .01). CONCLUSION: Total LVA percentage has a good predictive power on arrhythmia recurrence in a cohort of advanced scarred left atria in repeat procedures independent of the applied ablation strategy. Left atrial volume seems to have minor impact on the rhythm outcome in our study cohort.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Função do Átrio Esquerdo , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração , Frequência Cardíaca , Valor Preditivo dos Testes , Recidiva , Sistema de Registros , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Feminino , Ablação por Cateter/efeitos adversos , Pessoa de Meia-Idade , Idoso , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Fatores de Risco , Fatores de Tempo , Estudos Prospectivos , Reoperação , Medição de Risco , Resultado do Tratamento , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiologia , Remodelamento Atrial
2.
Artigo em Inglês | MEDLINE | ID: mdl-38956821

RESUMO

BACKGROUND: Despite advances in efficacy and safety of pulmonary vein isolation (PVI), atrial fibrillation (AF) recurrence after PVI remains common. PV-reconnection is the main finding during repeat PVI procedures performed to treat recurrent AF. OBJECTIVE: To analyze pulmonary vein (PV) reconnection patterns during repeat ablation procedures in a large cohort of consecutive patients undergoing radio frequency or cryoballoon-based PVI. METHODS: Retrospective analysis of PV-reconnection patterns and analysis of re-ablation strategies in consecutive index RF- and CB-based PVI and their respective re-ablation procedures during concomitant usage of both energy sources at a single high-volume center in Germany. RESULTS: A total of 610 first (06/2015-10/2022) and 133 s (01/2016-11/2022) repeat ablation procedures after 363 (60%) RF- and 247 (40%) CB-based index PVIs between 01/2015 and 12/2021 were analyzed. PV-reconnection was found in 509/610 (83%) patients at first and 74/133 (56%) patients at second repeat procedure. 465 of 968 (48%) initially via CB isolated PVs were reconnected at first re-ablation but 796 of 1422 initially RF-isolated PV (56%) were reconnected (OR: 0.73 [95% CI: 0.62-0.86]; p < .001). This was driven by fewer reconnections of the left PVs (LSPV: OR: 0.60 [95% CI: 0.42-0.86]; p = .005 and LSPV: 0.67 [0.47-0.95]; p = .026). PV-reconnection was more likely after longer, RF-based index PVI and in older females. Repeat procedures were shorter after CB-compared to after RF-PVI. CONCLUSIONS: Reconnection remains the most common reason for repeat AF ablation procedures after PVI. Our data suggest to preferentially use of the cryoballoon during index PVI, especially in older women.

3.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38607938

RESUMO

AIMS: Atrial fibrillation (AF) recurs in about one-third of patients after catheter ablation (CA), mostly in the first year. Little is known about the electrophysiological findings and the effect of re-ablation in very late AF recurrences (VLR) after more than 1 year. The aim of this study was to determine the characteristics and outcomes of the first repeat CA after VLR of AF after index CA. METHODS AND RESULTS: We analysed patients from a prospective Swiss registry that underwent a first repeat ablation procedure. Patients were stratified depending on the time to recurrence after index procedure: early recurrence (ER) for recurrences within the first year and late recurrence (LR) if the recurrence was later. The primary endpoint was freedom from AF in the first year after repeat ablation. Out of 1864 patients included in the registry, 426 patients undergoing a repeat ablation were included in the analysis (28% female, age 63 ± 9.8 years, 46% persistent AF). Two hundred and ninety-one patients (68%) were stratified in the ER group and 135 patients (32%) in the LR group. Pulmonary vein reconnections were a common finding in both groups, with 93% in the ER group compared to 86% in the LR group (P = 0.052). In the LR group, 40 of 135 patients (30%) had a recurrence of AF compared to 90 of 291 patients (31%) in the ER group (log-rank P = 0.72). CONCLUSION: There was no association between the time to recurrence of AF after initial CA and the characteristics and outcomes of the repeat procedure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Recidiva , Sistema de Registros , Reoperação , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Idoso , Fatores de Tempo , Suíça/epidemiologia , Fatores de Risco , Resultado do Tratamento , Estudos Prospectivos
4.
Pacing Clin Electrophysiol ; 47(7): 869-877, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38605573

RESUMO

BACKGROUND: Several studies have demonstrated that females have a higher risk of arrhythmia recurrence after pulmonary vein (PV) isolation for atrial fibrillation (AF). There are limited data on sex-based differences in PV reconnection rates at repeat ablation. We aimed to investigate sex-based differences in electrophysiological findings and atrial arrhythmia recurrence after repeat AF ablation METHODS: We conducted a retrospective study of 161 consecutive patients (32% female, age 65 ± 10 years) who underwent repeat AF ablation after index PV isolation between 2010 and 2022. Demographics, procedural characteristics and follow-up data were collected. Recurrent atrial tachycardia (AT)/AF was defined as any atrial arrhythmia ≥30 s in duration. RESULTS: Compared to males, females tended to be older and had a significantly higher prevalence of prior valve surgery (10 vs. 2%; P = .03). At repeat ablation, PV reconnection was found in 119 (74%) patients. Males were more likely to have PV reconnection at repeat ablation compared to females (81 vs. 59%; P = .004). Excluding repeat PV isolation, there were no significant differences in adjunctive ablation strategies performed at repeat ablation between females and males. During follow-up, there were no significant differences in freedom from AT/AF recurrence between females and males after repeat ablation (63 vs. 59% at 2 years, respectively; P = .48). CONCLUSIONS: After initial PV isolation, significantly fewer females have evidence of PV reconnection at the time of repeat ablation for recurrent AF. Despite this difference, long-term freedom from AT/AF was similar between females and males after repeat ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Recidiva , Reoperação , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Veias Pulmonares/cirurgia , Masculino , Feminino , Ablação por Cateter/métodos , Estudos Retrospectivos , Idoso , Fatores Sexuais , Pessoa de Meia-Idade
5.
Europace ; 25(2): 382-389, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36156137

RESUMO

AIMS: Although several studies have proved that repeat catheter ablation is beneficial to recurrent atrial tachycardia (AT)/atrial fibrillation (AF) after AF catheter ablation, the hard endpoints of the effect of catheter ablation on recurrent AT/AF patients after AF catheter ablation remains unclear. Our study aims to compare the effect of catheter ablation and drug therapy on recurrent AT/AF patients after AF catheter ablation. METHODS AND RESULTS: Four thousand nine hundred and thirteen consecutive patients with recurrent AT/AF after catheter ablation from the China-AF registry were enrolled. The patients were divided into two study groups: the repeat catheter ablation group and the medical therapy group. The primary endpoint is a composite of cardiovascular mortality or ischaemic stroke or major bleeding events. Secondary endpoints were each component of the primary endpoints and AF recurrence rate. Landmark analysis and Cox regression were used in the statistical analysis. We chose landmark 36 months as the primary landmark date. Over a median follow-up period of 40 ± 24 months, 4913 patients were divided into either the repeat ablation group or the medical therapy group. The cumulative incidence of the composite primary outcome was significantly lower in the repeat ablation group than the medical therapy group (adjusted hazard ratio = 0.56; 95% confidence interval: 0.35-0.89; P = 0.015) of landmark 36 months (2359 patients were included in medical therapy group and 704 patients were included in repeat ablation group at landmark 36 months). However, all secondary endpoints were not statistically different in the two groups, including cardiovascular mortality, ischaemic stroke, major bleeding events, and AF recurrence rate. CONCLUSION: Based on this research, in recurrent AT/AF patients after a catheter ablation procedure, compared with medical therapy, repeat catheter ablation may significantly reduce the risk of the endpoint of composite cardiovascular mortality, ischaemic stroke, and major bleeding events.


Assuntos
Fibrilação Atrial , Isquemia Encefálica , Ablação por Cateter , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Antiarrítmicos/efeitos adversos , Acidente Vascular Cerebral/etiologia , Taquicardia/etiologia , Hemorragia/induzido quimicamente , Sistema de Registros , AVC Isquêmico/etiologia , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
6.
Europace ; 26(1)2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-38127308

RESUMO

AIMS: Recurrences of ventricular tachycardia (VT) after initial catheter ablation is a significant clinical problem. In this study, we report the efficacy and risks of repeat VT ablation in patients with structural heart disease (SHD) in a tertiary single centre over a 7-year period. METHODS AND RESULTS: Two hundred ten consecutive patients referred for repeat VT ablation after previous ablation in our institution were included in the analysis (53% ischaemic cardiomyopathy, 91% males, median age 65 years, mean left ventricular ejection fraction 35%). After performing repeat ablation, the clinical VTs were acutely eliminated in 82% of the patients, but 46% of the cohort presented with VT recurrence during the 25-month follow-up. Repeat ablation led to a 73% reduction of shock burden in the first year and 61% reduction until the end of follow-up. Similarly, VT burden was reduced 55% in the first year and 36% until the end of the study. Fifty-two patients (25%) reached the combined endpoint of ventricular assist device implantation, heart transplantation, or death. Advanced New York Heart Association functional class, anteroseptal substrate, and periprocedural complication after repeat ablation were associated with worse prognosis independently of the type of cardiomyopathy. CONCLUSION: While complete freedom from VT after repeat ablation in SHD was difficult to achieve, ablation led to a significant reduction in VT and shock burden. Besides advanced heart failure characteristics, anteroseptal substrate and periprocedural complications predicted a worse outcome.


Assuntos
Cardiomiopatias , Ablação por Cateter , Cardiopatias , Taquicardia Ventricular , Masculino , Humanos , Idoso , Feminino , Volume Sistólico , Função Ventricular Esquerda , Cardiopatias/etiologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/etiologia , Cardiomiopatias/complicações , Cardiomiopatias/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
7.
Pacing Clin Electrophysiol ; 46(6): 535-542, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36689951

RESUMO

BACKGROUND: Durable electrical isolation of pulmonary veins (PVs) is associated with better outcomes after atrial fibrillation (AF) ablation, but previous studies of AF recurrence have reported high rates of reconnection despite successful acute isolation. This study aims to quantify historical trends in the durability of PV isolation (PVI) as radiofrequency (RF) ablation catheters, additional ablation technologies, and associated workflows have evolved. METHODS: The study population included adult patients receiving a first repeat ablation for AF between September 2013 and July 2019 at the study site. All index ablations were performed at the same site with an RF catheter and included PVI. Three generations of irrigated RF catheters based on the same technology platform were used by the site during the timeframe of this study. RESULTS: A total of 224 patients were included in the analysis. At repeat ablation, the mean number of patients with at least one reconnected PV dropped significantly with subsequent catheter generation, from 78.3% to 56.7% to 27.0% (p < .0001). Moreover, the mean number of reconnected PVs were significantly reduced from 1.48 to 0.92 to 0.47 (p < .0001), representing a 68.3% reduction across the 3 generations of devices. CONCLUSION: Significant improvement in durable PVI was seen with successive generations of RF catheter over a 6-year period. In addition to catheter technology, ancillary advances in ablation technologies, workflows, and operator experience likely contributed to these improvements.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Adulto , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Fatores de Tempo , Recidiva
8.
J Cardiovasc Electrophysiol ; 33(5): 885-896, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35257441

RESUMO

INTRODUCTION: Approximately 18% of patients with atrial fibrillation (AF) undergo a repeat ablation within 12 months after their index ablation. Despite the high prevalence, comparative studies on nonpulmonary vein (PV) target strategies in repeat AF ablation are scarce. Here, we describe 12 months efficacy of non-PV and PV target ablations as a repeat ablation strategy. METHODS: A multicentre retrospective, descriptive study was conducted with data of 280 patients who underwent repeat AF ablation. The ablation strategy for repeat ablation was at the operators' discretion. Non-PV target ablation (n = 140) included PV reisolation, posterior wall isolation, mitral line, roofline, and/or complex fractionated atrial electrogram ablation. PV target ablation (n = 140), included reisolation and/or wide atrium circumferential ablation. Patients' demographics and rhythm outcomes during 12 months follow-up were analyzed. RESULTS: At 12 months, more atrial tachyarrhythmias were observed in the non-PV target group (48.6%) compared to the PV target group (29.3%, p = .001). Similarly, a significantly higher AF and atrial tachycardia (AT) recurrence rate was observed after non-PV target ablation compared to PV target ablation (36.4% vs. 22.1% and 22.9% vs. 10.7%). After adjustment, a significantly higher risk of AT recurrence remained in the non-PV target group. Both groups significantly de-escalated antiarrhythmic drug use; de-escalation was more profound after PV target ablation. Patients with isolated PVs during non-PV target ablation had a significantly higher risk for AF recurrence than those with reconnected PVs. CONCLUSION: Compared to PV target ablation, non-PV target repeat ablation did not improve outcomes after 12 months and was independently associated with an increased risk for AT recurrences.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 33(9): 2003-2012, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35761754

RESUMO

INTRODUCTION: Arrhythmia recurrence after pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF) is common and often linked to pulmonary vein reconnection. In patients with arrhythmia recurrences despite durable PVI the optimal ablation approach is unclear. The purpose of the present study was to analyze efficacy of extended ablation maneuvers in these patients and predictors of procedural success. METHODS: Consecutive patients with durable PVI undergoing repeat ablation procedures were prospectively enrolled. Patients underwent substrate modification with creation of linear lesions and/or mechanism-specific atrial tachycardia (AT) ablation. Three dimensional-mapping images were analyzed for the presence of left atrial (LA) low-voltage areas according to published scoring systems. RESULTS: Seventy-four patients were analyzed. Mode of recurrence after durable PVI was AF in 27 patients (36.5%) and AT in 47 patients (63.5%). Linear lesion ablation was performed in 60 patients (81.1%). Twenty-four patients (32.4%) were treated for focal AT mechanisms. Mean follow-up was 565 ± 342 days. Estimated arrhythmia-free survival after 24 months was significantly higher in patients with AT than in patients with AF as mode of recurrence after durable PVI (42.9 ± 8.2% vs. 24.7 ± 8.5%, p = .023) and in patients without compared to patients with marked LA low-voltage areas (40.5 ± 9.2% vs. 22.8 ± 8.5%, p = .041). The mode of recurrence after durable PVI was the only independent predictor of further arrhythmia recurrence after repeat ablation. CONCLUSION: Arrhythmia-free survival following repeat ablation procedures in patients with durable PVI highly depends on mode of arrhythmia recurrence and the presence of LA low-voltage areas.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
10.
J Cardiovasc Electrophysiol ; 32(3): 628-638, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33410561

RESUMO

INTRODUCTION: Atrial fibrillation (AF) ablation is successful in 60%-80% of optimal candidates, with many patients requiring repeat procedures. We performed a detailed examination of electrophysiologic findings and clinical outcomes associated with first repeat AF ablations in the era of contact force-sensing radiofrequency (RF) catheters. METHODS: We retrospectively studied patients who underwent their first repeat AF ablations for symptomatic, recurrent AF at our center between 2013 and 2019. All repeat ablations were performed using contact force-sensing RF catheters. Pulmonary vein (PV) reconnections at repeat ablation and freedom from atrial arrhythmia 1 year after repeat ablation were evaluated. We further assessed these findings based on AF classification at the time of presentation for repeat ablation, index RF versus cryoballoon (CB) ablation, and duration (≥3 versus <3 years) between index and repeat procedures. RESULTS: Among 300 patients, there were 136 (45.3%) who presented for their first repeat ablations in persistent AF. During repeat ablation, at least one PV reconnection was found in 257 (85.6%) patients, while 159 (53%) had three to four reconnections. There was a similar distribution of reconnections among patients with persistent versus paroxysmal AF (mean: 2.7 ± 1.3 vs. 2.9 ± 1.2; p = .341), index RF versus CB ablation (mean: 2.8 ± 1.3 vs. 2.9 ± 1.2; p = .553), and ≥3 versus <3 years between index and repeat procedures (mean: 3.0 ± 1.1 vs. 2.7 ± 1.3; p = .119). At repeat ablation, the PVs were re-isolated in all patients, and additional non-PV ablation was performed in 171 (57%) patients. Freedom from atrial arrhythmia at 1-year follow-up after repeat ablation was 66%, similar among those with persistent versus paroxysmal AF (65.4% vs. 66.5%; p = .720), index RF versus CB ablation (66.7% vs. 68.9%; p = .930), and ≥3 versus <3 years between index and repeat ablations (64.4% vs. 66.7%; p = .760). Major complications occurred in a total of 4 (1.3%) patients. CONCLUSION: In a contemporary cohort of patients receiving their first repeat AF ablations using contact force-sensing RF catheters, PV reconnections were common, and freedom from atrial arrhythmia was 66% at 1-year follow-up. The distributions of PV reconnections and rates of freedom from atrial arrhythmia were similar, based on persistent versus paroxysmal AF at presentation for repeat ablation, index RF versus CB ablation, and duration between index and repeat procedures. The incidence of major complications was very low.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
11.
Scand Cardiovasc J ; 55(1): 29-34, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33073633

RESUMO

OBJECTIVES: We aimed to investigate the predictors of recurrent arrhythmia after repeated pulmonary vein isolation (PVI) performed in the era of contact force without additional substrate ablation. One of the predictors studied, ablation index (AI), incorporates power, contact force, and time in a weighted formula and is reported to predict lesion size in animals. Design. Consecutive patients (n = 108) undergoing repeat PVI without additional substrate modification using a contact force sensing catheter were included retrospectively at a tertiary center. All ablation points were analyzed offline. A new variable, normalized AI (AI corrected for the location of the lesion-anterior vs. posterior) was calculated. The patients were systematically followed with clinical visit and 12-lead ECG as well as review of the regional electronic patient files at 3 and 12 months after the procedure with 5-day Holter at 12 months. Results. Electrical reconnection to at least one pulmonary vein (PV) was seen in 97% of the patients. The recurrence rate was 35%. There was no recurrence in patients with nAI above 1.15 (n = 26). Patients with electrical reconnection of up to two PVs had a higher risk of recurrence compared with patients having electrical reconnection of three or four PVs (p = .003), and this risk was especially high in patients with persistent atrial fibrillation (69 [39-91]%). Conclusions. The risk of recurrence is higher in patients with ablations performed with low levels of AI and in patients with reconnection to up to two PVs. Our data may indicate the need for higher target levels of AI during repeat PVI than normally used during de-novo PVI.


Assuntos
Fibrilação Atrial , Veias Pulmonares , Arritmias Cardíacas/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Medição de Risco
12.
J Cardiovasc Electrophysiol ; 31(7): 1874-1876, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31626351

RESUMO

Patients with atrial fibrillation often undergo repeat catheter ablation for the recurrence of tachyarrhythmia. If the pulmonary veins were isolated in prior procedure, the operator should focus on substrate homogenization with identification and ablation of only arrhythmogenic areas.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
13.
J Cardiovasc Electrophysiol ; 31(5): 1068-1074, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32128924

RESUMO

AIMS: The current study sought to assess the impact of the utilized energy source during index ablation on long-term clinical outcomes after repeat ablation of atrial fibrillation (AF). Index ablation procedures were either performed using radiofrequency current (RFC) (RFC group) or cryoballoon (CB) ablation (CB group). Repeat ablation was performed by the use of RFC. METHODS: A total of 195 patients (138 RFC group; 57 CB group) with paroxysmal AF were included. All patients had a recurrence of AF following the index ablation procedure. Freedom from AF was estimated with the Kaplan-Meier method. RESULTS: After a 3 years follow-up, the estimated arrhythmia-free survival did not differ between the two groups (RFC group 48% vs CB group 47%, P = .78). During index ablation, procedure times were significantly shorter in the CB group (95 [80, 140] vs 140 [115, 164] minutes, P ≤ .001), whereas fluoroscopy times (16 [11; 22] vs 19 [14; 25] minutes, P = .003), the dose area product (1862 [1203; 2922] vs 3148 [1756; 5888] cGycm2 , P ≤ .001) and the amount of contrast dye (92 ± 32 vs 123 ± 33 mL, P ≤ .001) were significantly lower in the RFC group. During repeat ablation, procedure times were significantly shorter in patients being initially treated with RFC (115 [85; 145] vs 125 [105; 150] minutes, P = .007). There was a trend towards a higher pulmonary vein reconnection rate in the RFC group without meeting statistical significance (P = .074). CONCLUSIONS: In patients with repeat ablation of AF, index RFC or CB ablation are equally effective in terms of freedom from AF. Although CB ablation results in shorter index procedures times, durations of repeat ablation are significantly longer.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Intervalo Livre de Doença , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
14.
Pacing Clin Electrophysiol ; 43(7): 687-697, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32510595

RESUMO

BACKGROUND: Which technique is better for repeat ablation in patients with atrial fibrillation (AF) remains unclear. The aim of the study was to compare long-term efficacy of repeat ablation using the alternative technique for the first redo ablation procedure: (a) cryoballoon (CB) re-ablation after a failed index pulmonary vein isolation (PVI) with radiofrequency (RF) ablation, RF-then-CB group or (b) RF repeat ablation following a failed CB ablation, CB-then-RF group. METHODS: Within the 1STOP Italian Project, consecutive patients undergoing repeat ablation with a different technique from the index procedure were included. RESULTS: We studied 474 patients, 349 in RF-then-CB and 125 in CB-then-RF group. Less women (21% vs 30%; P = .041), more persistent AF (33% vs 22%; P = .015), longer duration of AF (60 vs 31 months; P < .001), and more hypertension (50% vs 36%; P = .007) were observed in the RF-then-CB cohort as compared with the CB-then-RF group. The number of reconnected PVs was 3.7 ± 0.7 and 1.4 + 1.3 in RF-then-CB and CB-then-RF group, respectively (P < .001). During the follow-up, significantly less AF recurrence occurred in the CB-then-RF group (22% vs 8%, HR = 0.46; 95% CI: 0.24-0.92; P = .025). Cohort designation was the only independent predictor of AF recurrence. CONCLUSION: Alternation of energy source for repeat ablation was safe and effective, regardless the energy used first. However, patients initially treated with CB PVI undergoing repeat ablation with RF current had less AF recurrence at long-term follow-up as compared with those originally treated by RF ablation receiving a CB repeat ablation.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Ablação por Radiofrequência/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Reoperação
15.
Europace ; 21(10): 1494-1501, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31327016

RESUMO

AIMS: Arrhythmia recurrence is a common clinical problem in patients with pulmonary vein stenosis (PVS) following catheter ablation of atrial fibrillation. The study sought to analyse the management of arrhythmia recurrence in patients with PVS. METHODS AND RESULTS: Retrospective analysis was performed on 29 patients with high-degree PVS. Follow-up contained clinical visits, Holter-electrocardiogram recordings and invasive pulmonary vein (PV) angiography and electrophysiological studies. Arrhythmia recurrence was observed in 18 patients (62%) after PVS formation. Fifteen of 18 patients (83.3%) with and 1 of 11 patients (9.1%) without arrhythmia recurrence had electrical PV reconnection (P = 0.0003). In 14 of 16 patients repeat pulmonary vein isolation (PVI) was conducted (radiofrequency ablation in 12 and cryoballoon ablation in 2 cases). Repeat PVI was successful in all PVs in nine patients and incomplete in five patients (failed attempt in two patients with stent implantation, no attempt in three patients with stenotic PVs). Freedom from arrhythmia recurrence was estimated at 56.3% [95% confidence interval (CI) 36.4-72.0%] after 24 months. At the end of the follow-up, complete PVI was documented in 19 of 23 patients (82.6%) with stable sinus rhythm and in 2 of 6 patients with arrhythmia recurrence (33.3%) (P = 0.0335). The Kaplan-Meier estimate of recurrence-free survival of restenosis after interventional PVS treatment was similar in patients without and with repeat ablation [75.6% (95% CI 57.0-94.3%) and 67.0% (95% CI 43.2-90.7%) after 500 days, P = 0.77]. CONCLUSIONS: Pulmonary vein reconnection is the major driver of arrhythmia recurrence in PVS patients. Repeat PVI is feasible and does not lead to progression of PVS or restenosis if the procedure is carefully performed.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Sistema de Condução Cardíaco/fisiopatologia , Complicações Pós-Operatórias , Estenose de Veia Pulmonar/etiologia , Stents , Procedimentos Cirúrgicos Vasculares/métodos , Angiografia , Fibrilação Atrial/fisiopatologia , Criocirurgia/efeitos adversos , Eletrocardiografia Ambulatorial , Feminino , Seguimentos , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Estenose de Veia Pulmonar/diagnóstico , Estenose de Veia Pulmonar/cirurgia , Resultado do Tratamento
16.
Pacing Clin Electrophysiol ; 42(10): 1365-1373, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31355938

RESUMO

BACKGROUND: The influence of risk factors on atrial fibrillation (AF) ablation recurrence is increasingly recognized. We present a sub-analysis of the European Society of Cardiology-European Heart Rhythm Association-European Society of Cardiology AF ablation long-term registry on the effect of traditional risk factors for AF on postablation recurrence, reablation, and complications using real-world data. METHODS: Risk factors for AF were defined as body mass index ≥27 kg/m², hypertension, chronic obstructive pulmonary disease, diabetes, alcohol ≥2 units/day, sleep apnea, smoking, no/occasional sports activity, moderate/severe mitral or aortic valve disease, any cardiomyopathy, peripheral vascular disease, chronic kidney disease, heart failure, coronary artery disease/infarction, and previous pacemaker/defibrillator implant. Patients were divided in two groups with ≥1 or without risk factors. Primary outcomes were arrhythmia recurrence after blanking period, reablation, and adverse events or death. Differences between the groups and the influence of individual risk factors were analyzed using multivariate Cox regression. RESULTS: Three thousand sixty nine patients were included; 217 patients were without risk factors. Risk factor patients were older (58.4 vs 54.1 years), more often female (32% vs 19.8%) and had more often persistent AF (27.2% vs 23.5%). In a multivariate analysis, patients without risk factors had a hazard ratio of 0.70 (95% CI 0.49-0.99) for recurrence compared to risk factor patients. The multivariate hazard ratios for reablation or adverse events/death were not different between the two groups. Hypertension and body mass index were univariate predictors of recurrence. CONCLUSIONS: Patients with ≥1 risk factor had a 30% higher risk for arrhythmia recurrence after ablation, but no differences in risk for repeat ablations and adverse events or death.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Idoso , Comorbidade , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Sistema de Registros , Fatores de Risco
18.
J Cardiovasc Electrophysiol ; 26(4): 371-377, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25534677

RESUMO

INTRODUCTION: Pulmonary vein (PV) status, arrhythmia sources, and outcomes with ≥3 ablation procedures have not been characterized. METHODS AND RESULTS: All patients with ≥3 procedures were included and underwent antral reisolation of reconnected PVs and ablation of non-PV triggers. Of 2,886 patients who underwent PVI, 181 (6%) had more than 2 ablation procedures (3 procedures in 146 and ≥4 procedures in 35). In 12 patients, the clinical arrhythmia was other than AF. Of the remaining 169 patients, 69 (41%) had 4 reconnected PVs, 27 (16%) had 3, 31 (18%) had 2, and 29 (17%) had 1. Only 13 (8%) had all PVs still isolated. Provocative techniques in 127 patients initiated PV triggers in 92 patients, including AF or PV atrial tachycardia in 64 (50%), and reproducible PV APDs in 28 (22%). Thirty-six (20%) had a new non-PV trigger targeted. At a mean of 36 months (12-119 months) after last procedure, 63 patients (47%) had no AF off antiarrhythmic drugs (AAD); 28 (21%) had no AF with AAD; and 18 (13%) had rare AF with good symptom control; 26 patients (19%) had recurrent AF. CONCLUSIONS: At time of third or greater AF ablation, PV reconnection is the rule (92%) and PV triggers initiating AF can be demonstrated. Following repeat PVI and targeting non-PV triggers, 81% of patients had clinical AF control. Our findings suggest that PV reisolation and attempts to identify and eliminate non-PV triggers are effective and support the role of multiple repeat procedures for AF recurrence.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Philadelphia , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
19.
J Clin Med ; 13(2)2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38276082

RESUMO

Focal pulsed field ablation (PFA) is a novel technique for treating cardiac arrhythmias. It has demonstrated positive results in initial studies and has a good safety profile. In recent studies, PFA was often utilized for first-time pulmonary vein isolation (PVI) and was performed under general anesthesia. In our study, we assessed the feasibility, safety, acute procedural efficacy, and efficiency of focal PFA under deep sedation in patients, 80% of whom had undergone at least one left atrial ablation previously. We treated 30 patients (71 ± 7, 46% male) using the CENTAURI system for various atrial arrhythmias, including atrial fibrillation, typical and atypical atrial flutter, and focal atrial tachycardia. The average procedure and fluoroscopy times were 122 ± 43 min and 9 ± 7 min, respectively. A total of 83.33% of patients received additional line ablations beyond PVI, specifically targeting the posterior box and anterior mitral line. All ablations were successfully performed in deep sedation with only one major and one minor complication observed. The major complication was a vasospasm of the right coronary artery during ablation of the cavotricuspid isthmus, which was treated successfully with intracoronary nitroglycerin. All patients could be discharged in sinus rhythm. Moreover, adenosine appears effective in identifying dormant conduction in some patients after focal PFA. In conclusion, focal PFA is an effective approach for complex left atrial ablations under deep sedation, offering both high efficacy and efficiency with a reliable safety profile. Studies on long-term outcomes are needed.

20.
J Interv Card Electrophysiol ; 66(7): 1729-1737, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37195355

RESUMO

BACKGROUND: Pulsed field ablation (PFA) is a novel ablation technology recently adopted in the treatment of atrial fibrillation (AF). Currently, little is known about the durability of PFA ablation lesions. METHODS: We investigated patients who underwent redo-ablation due to recurrent AF/atrial-flutter or tachycardia (AFL/AT) following PVI with PFA. We report electrophysiological findings and ablation strategy during redo-ablation. RESULTS: Of 447 patients undergoing index PVI with PFA, 14 patients (age: 61.9±10.8 years; 7 (50.0%) males; left atrial volume index (n=10): 39.4±14.6 mL/m2) were referred for redo-ablation. Initial indication was paroxysmal-AF in 7 patients, persistent-AF in 6 and long-standing-persistent-AF in one patient. Mean time-to-recurrence was 4.9±1.9 months. Three patients received additional posterior-wall-isolation during index PFA. Twelve (85.7%) patients suffered AF recurrence and 5/12 had concomitant AFL. In the remaining 2 patients, one had a (box-dependent) AFL, and one had an atypical AT. No patients had all PVs reconnected. Reconnection in zero, one, two or three PVs was found in 35.7%, 21.4%, 14.3%, and 28.6% of patients, respectively. All 7 patients with zero or one reconnection with AF recurrence received additional/repeat posterior-wall-isolation during re-ablation, while in the others, PVs were re-isolated. Patients with only AFL/AT had no reconnection of PVs, and the substrate was successfully ablated. CONCLUSIONS: Durable PVI (all PV's isolated) was observed in over one-third of patients at re-do. The predominant recurrent arrhythmia following PVI-only was AF. Concomitant (35.7%) or isolated (14.3%) AFL/AT recurrence was observed in 50% of patients.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Átrios do Coração/cirurgia , Flutter Atrial/cirurgia , Eletrofisiologia Cardíaca , Ablação por Cateter/métodos , Recidiva , Resultado do Tratamento