J Nucl Cardiol ; 24(2): 698-707, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-26846369

RESUMO

BACKGROUND: A phantom assembly that simulates the respiratory motion of the heart was used to investigate artifacts and their impact on defect detection. METHODS: SPECT/CT images were acquired for phantoms with and without small and large cardiac defects during normal and deep breathing, and also at four static respiratory phases. Acquisitions were reconstructed with and without AC, and with misalignment of transmission and emission scans. A quantitative analysis was performed to assess artifacts. Two physicians reported on defect presence or absence and their results were evaluated. RESULTS: All large defects were correctly reported. Attenuation reduced uptake in the basal LV walls, increasing FN physicians' reports for small defects. Respiratory motion reduced uptake mainly in the anterior and inferior walls increasing FP and FN reports on images without and with small defects, respectively. Artifacts due to misalignment between CT and SPECT scans in normal breathing phantoms did not influence the physicians' reports. CONCLUSIONS: Attenuation and respiratory motion correction should be applied to reduce artifacts before reporting on small defects in deep breathing conditions. Artifacts due to misalignment between CT and SPECT scans do not affect defect detection in normal breathing when the LV is co-registered in SPECT and CT images prior to AC.


Assuntos
Artefatos , Cardiopatias/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/instrumentação , Imagens de Fantasmas , Mecânica Respiratória , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Movimento (Física) , Imagem de Perfusão do Miocárdio/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/métodos
2.
Phys Eng Sci Med ; 45(1): 63-72, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34973119

RESUMO

Cranio-caudal respiratory motion and liver activity cause a variety of complex myocardial perfusion (MP) artifacts, especially in the inferior myocardial wall, that may also mask cardiac defects. To assess and characterise such artifacts, an anthropomorphic thorax with moving thoracic phantoms can be utilised in SPECT MP imaging. In this study, a liver phantom was developed and anatomically added into an anthropomorphic phantom that also encloses an ECG beating cardiac phantom and breathing lungs' phantom. A cranio-caudal respiratory motion was also developed for the liver phantom and it was synchronised with the corresponding ones of the other thoracic phantoms. This continuous motion was further divided into isochronous dynamic respiratory phases, from end-exhalation to end-inspiration, to perform SPECT acquisitions in different respiratory phases. The new motions' parameters and settings were measured by mechanical means and also validated in a clinical environment by acquiring CT images and by using two imaging software packages. To demonstrate the new imaging capabilities of the phantom assembly, SPECT/CT MP acquisitions were performed and compared to previous phantom and patients studies. All thoracic phantoms can precisely perform physiological motions within the anthropomorphic thorax. The new capabilities of the phantom assembly allow to perform SPECT/CT MP acquisitions for different cardiac-liver activity ratios and cardiac-liver proximities in supine and, for first time, in prone position. Thus, MP artifacts can be characterised and motion correction can be performed due to these new capabilities. The impact of artifacts and motion correction on defect detection can be also investigated.


Assuntos
Imagem de Perfusão do Miocárdio , Humanos , Fígado/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Imagens de Fantasmas , Tórax/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos