Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Neurophysiol Clin ; 52(2): 174-177, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35296384

RESUMO

We investigated how properties of single-fiber action potentials (SFAP) and jitter changed in different recording sites in patients with myopathy and controls. SFAP and jitter were recorded using a disposable single-fiber electrode in the biceps brachii muscle of three patients and controls in two sites: i) near the end-plate zone (EPZ), ii) near the tendon. SFAP and spike duration were longer in patients than in controls. Moving the needle away from the EPZ did not change the electrophysiologic parameters. Longer SFAP duration may reflect slow velocity in muscle fibers and serve as an indicator for small fiber size in myopathy.


Assuntos
Doenças Musculares , Tendões , Potenciais de Ação/fisiologia , Eletromiografia , Humanos , Fibras Musculares Esqueléticas/fisiologia , Músculo Esquelético/fisiologia , Doenças Musculares/diagnóstico , Tendões/fisiologia
2.
Biomed Eng Lett ; 7(1): 45-53, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30603150

RESUMO

Simulation models are necessary for testing the performance of newly developed approaches before they can be applied to interpreting experimental data, especially when biomedical signals such as surface electromyogram (SEMG) signals are involved. A new and easily implementable surface EMG simulation model was developed in this study to simulate multi-channel SEMG signals. A single fiber action potential (SFAP) is represented by the sum of three Gaussian functions. SFAP waveforms can be modified by adjusting the amplitude and bandwidth of the Gaussian functions. SEMG signals were successfully simulated at different detected locations. Effects of the fiber depth, electrode position and conduction velocity of SFAP on motor unit action potential (MUAP) were illustrated. Results demonstrate that the easily implementable SEMG simulation approach developed in this study can be used to effectively simulate SEMG signals.

3.
Med Biol Eng Comput ; 54(8): 1257-67, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27016364

RESUMO

Electrode designs and strategies for electroneurogram recordings are often tested first by computer simulations and then by animal models, but they are rarely implanted for long-term evaluation in humans. The models show that the amplitude of the potential at the surface of an axon is higher in front of the nodes of Ranvier than at the internodes; however, this has not been investigated through in vivo measurements. An original experimental method is presented to emulate a single fiber action potential in an infinite conductive volume, allowing the potential of an axon to be recorded at both the nodes of Ranvier and the internodes, for a wide range of electrode-to-fiber radial distances. The paper particularly investigates the differences in the action potential amplitude along the longitudinal axis of an axon. At a short radial distance, the action potential amplitude measured in front of a node of Ranvier is two times larger than in the middle of two nodes. Moreover, farther from the phantom axon, the measured action potential amplitude is almost constant along the longitudinal axis. The results of this new method confirm the computer simulations, with a correlation of 97.6 %.


Assuntos
Potenciais de Ação/fisiologia , Axônios , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Axônios/fisiologia , Simulação por Computador , Eletrodos , Desenho de Equipamento
4.
Biomed Eng Comput Biol ; 5: 33-42, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-25288900

RESUMO

The convolution of the transmembrane current of an excitable cell and a weighting function generates a single fiber action potential (SFAP) model by using the volume conductor theory. Here, we propose an empirical muscle IAP model with multiple Erlang probability density functions (PDFs) based on a modified Newton method. In addition, we generate SFAPs based on our IAP model and referent sources, and use the peak-to-peak ratios (PPRs) of SFAPs for model verification. Through this verification, we find that the relation between an IAP profile and the PPR of its SFAP is consistent with some previous studies, and our IAP model shows close profiles to the referent sources. Moreover, we simulate and discuss some possible ionic activities by using the Erlang PDFs in our IAP model, which might present the underlying activities of ions or their channels during an IAP.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA