Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Catheter Cardiovasc Interv ; 99(3): 861-866, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34388299

RESUMO

OBJECTIVES: The aim of this study was to determine the safety of eliminating the pre-discharge transthoracic echocardiogram (TTE) on 30-day outcomes in patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: TTE is utilized before, during, and after TAVR. Post-procedural, pre-discharge TTE assists in assessment of prosthesis function and detection of clinically significant paravalvular leak (PVL) after TAVR. METHODS: Patients who underwent TAVR at Mayo Clinic from July 2018 to July 2019 were included in a prospective institutional registry. Patients undergoing TAVR prior to February 2019 received a pre-discharge TTE, while those undergoing TAVR after February 2019 did not. Both cohorts were evaluated with TTE at 30 days post-TAVR. RESULTS: A total of 330 consecutive patients were included. Of these, 160 patients (age 81.1 ± 7.6) had routine pre-discharge TTE, while 170 patients (age 78.9 ± 7.5) were dismissed without routine pre-discharge TTE. Mortality at 30 days was similar between the two groups (0% and 1.2%, respectively). One episode of PVL requiring intervention (0.6%) occurred in the pre-discharge TTE group and none in the group without pre-discharge TTE at 30-day follow-up. There was a similar incidence of total composite primary and secondary adverse events between the cohort receiving a pre-discharge TTE and those without (28.1% vs. 25.3%, P = 0.56) at 30 days. The most common event was need for permanent pacemaker or ICD implantation in both groups (13.1% vs. 11.8%, P = 0.71). CONCLUSIONS: Elimination of the pre-discharge TTE is safe and associated with comparable 30-day outcomes to routine pre-discharge TTE. These findings have implication for TAVR practice cost-efficiency and health care utilization.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Alta do Paciente , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 99(7): 2071-2079, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35582829

RESUMO

BACKGROUND: The natural history of peridevice leak (PDL) following left atrial appendage occlusion (LAAO) is unknown. This study sought to investigate changes of PDL from 2 until 12 months after LAAO, using cardiac computed tomography (CT), and to assess the potential association between persistent PDL and clinical outcomes METHODS: Single-center observational study of Amplatzer LAAO implants between 2010 and 2017 (n = 206). Patients with 2 and 12 months cardiac CT were included in the study (n = 153). Images were blindly analyzed. PDL was characterized by frequency and size at the device disc, lobe, and left atrial appendage contrast patency. Patients were followed for the composite outcome of ischemic stroke, transient ischemic attack, systemic embolism, or all-cause death. Median follow up from LAAO was 3.1 (2.3-4.3) years. RESULTS: Contrast patency was present in 101 (66%) and 72 (47%) (p < 0.001) at 2 and 12 months, respectively. PDL was identified at the disc in 103 (67%) patients at 2 months versus 93 (61%) at 12 months (p = 0.08), and at the lobe in 29 (19%) at both time points. PDL area at the disc did not change significantly over time, ∆$\unicode{x02206}$ area: -8.95 mm (95% confidence interval [CI]: -18.9; 1.01) p = 0.08. Permanent atrial fibrillation was independently associated with persistent PDL. Persistent versus no PDL was associated with a 62% worse clinical outcome, however not statistically significant, hazard ratio (HR): 1.62 (95% CI: 0.9-2.93), p = 0.11. CONCLUSION: Persistent PDL was frequently observed following LAAO with Amplatzer devices. The PDL frequency and size appeared unchanged between 2 and 12 months. Persistent PDL was not significantly associated with worse clinical outcomes, yet this needs further delineation in future studies.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Humanos , Dispositivo para Oclusão Septal/efeitos adversos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Tomografia , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 99(6): 1839-1847, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35312231

RESUMO

OBJECTIVES: We aimed to compare indirect mitral annuloplasty using the Carillon Mitral Contour System and edge-to-edge repair via MitraClip in atrial functional mitral regurgitation (aFMR). BACKGROUND: In patients with left ventricular dilation, both edge-to-edge repair and indirect mitral annuloplasty are effective in reducing mitral regurgitation, while no clinical trial has compared both interventional methods in aFMR. METHODS: In a retrospective single-center analysis, 41 patients with aFMR underwent either edge-to-edge mitral valve repair (MitraClip group, n = 20) or indirect annuloplasty (Carillon group, n = 21). RESULTS: Both treatment groups showed high procedural success (100%) and low complication rates. Both treatment groups showed a comparable reduction of New York Heart Association (NYHA) classification postimplantation, after 3- and 12-months follow-up. Quantitative reduction in echocardiographic FMR parameters was significantly pronounced in the MitraClip group (reduction in vena contracta MitraClip vs. Carillon: postimplantation -74.6 ± 25.8 vs. -29.1 ± 17.8%, 3-months follow-up -65.8 ± 31.2 vs. -33.9 ± 17.5%, 12-months follow-up -50.8 ± 27.9 vs. -23.9 ± 17.0%, p < 0.05). Qualitative mitral valve assessment showed improved FMR class postimplantation, at 3-and 12-months follow-up in both treatment groups. Edge-to-edge repair revealed better results with lower average FMR classification compared to indirect coronary sinus-based annuloplasty. After 12-months left atrial (LA) volume was significantly reduced in the Carillon group, while in the MitraClip group no LA remodeling was found (reduction in LA volume MitraClip vs. Carillon at 12 months: +9.6 ± 25.1% vs. -12.3 ± 12.7%, p < 0.05). CONCLUSIONS: Both indirect mitral valve annuloplasty and edge-to-edge repair are feasible and safe in patients with aFMR, while the reduction in FMR was pronounced in the edge-to-edge repair group.


Assuntos
Implante de Prótese de Valva Cardíaca , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 99(7): 2082-2091, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35420255

RESUMO

OBJECTIVES: To investigate the efficacy and safety of larger valve sizing beyond the commercially recommended annular range in transcatheter aortic valve replacement (TAVR) with balloon-expandable transcatheter heart valve (THVs). BACKGROUND: The clinical implications of larger balloon-expandable THV implantation with underfilling are poorly evaluated. METHODS: This retrospective study included 692 consecutive patients who underwent TAVR with SAPIEN3. A total of 271 patients who underwent SAPIEN 3 implantation were analyzed based on three border zones (Zone 1: 300-345 mm2 , 23 vs. 20 mm; Zone 2: 400-430 mm2 , 26 vs. 23 mm; Zone 3: 500-546 mm2 , 29 vs. 26 mm). The primary endpoint was the effective orifice area (EOA) assessed by echocardiography at 1 year, and secondary endpoints were a 30-day mortality rate, procedural complications during TAVR, and a composite of death from any cause and heart failure requiring rehospitalization at 1 year. RESULTS: At 1-year follow-up, the EOA in the larger valve groups was greater than that in the recommended valve group in each zone (Zone 1: 1.45 ± 0.03 vs. 1.06 ± 0.06 cm2 , p < 0.001; Zone 2: 1.83 ± 0.05 vs. 1.41 ± 0.05 cm2 , p < 0.001; Zone 3: 1.93 ± 0.07 vs. 1.69 ± 0.07 cm2 , p = 0.02). No significant difference in the secondary endpoint was observed in any of the zones. CONCLUSIONS: Implantation of the out-of-range larger SAPIEN 3 THVs with underfilling was associated with greater EOA at the 1-year follow-up and feasible in the selected patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 98(6): E932-E937, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-34245208

RESUMO

BACKGROUND: The predictors and clinical significance of increased Doppler-derived mean diastolic gradient (MG) following transcatheter edge-to-edge mitral valve repair (MVTEER) remain controversial. OBJECTIVE: We sought to examine baseline correlates of Doppler-derived increased MG post-MVTEER and its impact on intermediate-term outcomes. METHODS: Patients undergoing MVTEER were analyzed retrospectively. Post-MVTEER increased MG was defined as >5 mmHg or aborted clip implantation due to increased MG intraprocedurally. Baseline MG and 3D-guided mitral valve area (MVA) by planimetry were retrospectively available in 233 and 109 patients. RESULTS: 243 patients were included; 62 (26%) had MG > 5 mmHg post-MVTEER or aborted clip insertion, including 7 (11%) that had aborted clip implantation. Mortality occurred in 63 (26%) during a median follow up of 516 days (IQR 211, 1021). Increased post-MVTEER MG occurred more frequently in females (44% vs. 16%, p < 0.001), those with baseline MVA <4.0 cm2 (71% vs. 16%), baseline MG ≥4 mmHg (61% vs. 20%), or multiple clips implanted (33% vs. 21%, p = 0.04). Increased post-MVTEER MG was associated with increased subsequent mortality compared to those with normal gradient (HR 1.91 95% CI 1.15-3.18 p = 0.016) as was aborted clip insertion compared to all others (HR 5.23 95% CI 2.06-13.28 p < 0.001). CONCLUSIONS: Smaller baseline MVA and increased baseline MG are associated with increased MG post-MVTEER and patients with a Doppler-derived post-MVTEER MG >5 mmHg suffered excess subsequent mortality. In high risk patients considered for MVTEER, identification of those at risk of iatrogenic mitral stenosis with MVTEER is important as they may be optimally treated with alternate surgical or transcatheter therapies.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Estenose da Valva Mitral , Cateterismo Cardíaco/efeitos adversos , Feminino , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 97(6): E887-E892, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33175473

RESUMO

Transcatheter mitral valve replacement (TMVR) is an exciting alternative therapy for complex patients with mitral valve disease. Experience with TMVR is new and there is a lot yet to discover about their durability, long-term outcomes, and complications including mitral transcatheter heart valve (THV) thrombosis. Many factors have been speculated to increased risk of THV thrombosis. Here, we report a case of a 72-year-old woman who developed mitral THV thrombosis after undergoing TMVR for severe mitral regurgitation with mitral annular calcification. We reviewed 42 TMVR papers with 1,484 patients, including 60 with mitral THV thrombosis. We discussed the most common strategies used for mitral THV thromboprophylaxis and treatment.


Assuntos
Implante de Prótese de Valva Cardíaca , Trombose , Tromboembolia Venosa , Idoso , Anticoagulantes , Cateterismo Cardíaco/efeitos adversos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Trombose/diagnóstico por imagem , Trombose/etiologia , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 98(5): E758-E767, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-33682347

RESUMO

OBJECTIVES: Right ventricular (RV) dysfunction and tricuspid regurgitation (TR) are associated with adverse outcomes in severe aortic stenosis (AS) patients. Our aim was to evaluate the association between ≥moderate TR and RV dysfunction on long-term mortality following transcatheter aortic valve replacement (TAVR). METHODS: A retrospective analysis of the Israeli multicenter TAVR registry among 4,344 consecutive patients, with all-cause mortality as the main outcome measure. RESULTS: Echocardiographic assessment of TR grade and RV dysfunction was available for 3,733 and 1,850 patients, of whom ≥moderate TR and RV dysfunction was noted for 478(13%) and 78(4%), respectively. The mean follow-up time was 2.9 ± 2.3 years. In univariate models, ≥Moderate TR and ≥moderate RV dysfunction were associated with increased long-term mortality (HR 1.45, 95% CI 1.24-1.69, p < .001 and HR 1.73, 95% CI 1.21-2.47, p = 0.003, respectively). These finding did not remained significant after adjusting to echocardiographic parameters. A subset of patients with no improvement in RV function had the highest long-term mortality risk (HR 3.3, 95% CI 1.95-5.7, p < .001). CONCLUSION: When adjusted to multiple echocardiographic characteristics baseline ≥Moderate TR and ≥moderate RV dysfunction were not associated with long-term mortality following TAVR. Persistent RV dysfunction following TAVR was associated with the highest risk for mortality.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Tricúspide , Disfunção Ventricular Direita , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia
8.
Catheter Cardiovasc Interv ; 97(5): E692-E696, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33502083

RESUMO

Mitral valve perforation is a rare cause of mitral regurgitation. We present a case of a 16-year-old patient with mitral valve regurgitation after redo-cardiac surgery for recurrent subaortic stenosis. Transthoracic echocardiography revealed a mitral regurgitation with an eccentric jet causing a significant regurgitation documented by the presence of a convergence flow over the hole. This finding was corroborating by transesophageal echocardiography locating the perforation from the region of A2 scallop. Three-dimensional transesophageal echocardiography confirmed these findings and played a key role guiding the procedure. Typical approach is usually a cardiac surgical procedure based on repair the perforation, but the mitral orifice was successfully closed percutaneously using an Amplatzer Duct Occluder II (ADO II; Abbott Vascular, IL).


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Cardiopatia Reumática , Adolescente , Ecocardiografia Transesofagiana , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 98(3): E483-E485, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33600044

RESUMO

Despite TAVR emerging as the gold standard for a broad spectrum of patients, it is associated with serious complications. In this report we present a case, where a TAVR procedure led to a perforation at the aortomitral continuity, discuss the risk factors for the occurrence of perforations and how we decided to treat the patient.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 95(6): 1124-1128, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31318477

RESUMO

Pseudoaneurysm of the non-coronary sinus of Valsalva is an exceptionally rare but potentially fatal complication of percutaneous coronary interventions (PCI). Here, we report a case of a 53-year-old man with pseudoaneurysm of the non-coronary sinus of Valsalva following PCI who presented with recurrent chest pain and was treated successfully by closure of the orifice of the pseudoaneurysm and coronary artery bypass grafting.


Assuntos
Falso Aneurisma/etiologia , Angina Instável/terapia , Angioplastia Coronária com Balão/efeitos adversos , Aneurisma Aórtico/etiologia , Doença da Artéria Coronariana/terapia , Doença Iatrogênica , Seio Aórtico/lesões , Lesões do Sistema Vascular/etiologia , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/cirurgia , Angina Instável/diagnóstico por imagem , Angioplastia Coronária com Balão/instrumentação , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Ponte de Artéria Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Stents Farmacológicos , Humanos , Masculino , Pessoa de Meia-Idade , Seio Aórtico/diagnóstico por imagem , Seio Aórtico/cirurgia , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA