Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 252
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38895766

RESUMO

BACKGROUND: In 5%-25% of non-ST-elevation acute coronary syndrome (NSTE-ACS) patients, coronary angiography reveals no obstructive coronary arteries (MINOCA). Coronary microvascular disease (CMD) is a potential causal pathophysiological mechanism in these patients and can be diagnosed by continuous thermodilution assessment. Recently, the microvascular resistance reserve (MRR) has been introduced as a novel index to assess the vasodilatory capacity of the microcirculation. However, continuous thermodilution and MRR have never been investigated in the acute setting in MINOCA patients and invasive assessment of the microcirculation in these patients are currently lacking. AIMS: The objectives of the study were to investigate the incidence of CMD (MRR ≤ 2.7) in patients with MINOCA and to evaluate the feasibility and safety of continuous thermodilution-based assessment during index coronary angiography in the acute setting. METHODS: This study was a prospective, observational, pilot study investigating coronary physiology in the acute setting in MINOCA patients. Patients admitted with a diagnosis of NSTE-ACS were eligible for inclusion. RESULTS: In total, 19 MINOCA patients were included in this analysis; the mean age was 70 ± 9 years, and 79% were females. CMD was present in 6 patients (32%). Qrest was significantly higher in the MRR ≤ 2.7 group compared to the MRR > 2.7 group (0.076 [0.057-0.100] vs. 0.049 [0.044-0.071] L/min, p = 0.03). Rµ,rest was significantly lower in the MRR ≤ 2.7 group compared to the MRR > 2.7 group (1083 [710-1510] vs. 1563 [1298-1970] WU, p = 0.04). No periprocedural complications or hemodynamic instability have occurred during continuous thermodilution assessment during the index coronary angiography. CONCLUSION: In patients admitted for MINOCA undergoing immediate coronary angiography, continuous thermodilution assessment and MRR are feasible and safe in the acute setting, and evidence of functional CMD could be observed in one-third of the MINOCA patients.

2.
Catheter Cardiovasc Interv ; 103(6): 885-896, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38566527

RESUMO

BACKGROUND: Two invasive methods are available to estimate microvascular resistance: bolus and continuous thermodilution. Comparative studies have revealed a lack of concordance between measurements of microvascular resistance obtained through these techniques. AIMS: This study aimed to examine the influence of vessel volume on bolus thermodilution measurements. METHODS: We prospectively included patients with angina with non-obstructive coronary arteries (ANOCA) undergoing bolus and continuous thermodilution assessments. All patients underwent coronary CT angiography to extract vessel volume. Coronary microvascular dysfunction was defined as coronary flow reserve (CFR) < 2.0. Measurements of absolute microvascular resistance (in Woods units) and index of microvascular resistance (IMR) were compared before and after volumetric adjustment. RESULTS: Overall, 94 patients with ANOCA were included in this study. The mean age was 64.7 ± 10.8 years, 48% were female, and 19% had diabetes. The prevalence of CMD was 16% based on bolus thermodilution, while continuous thermodilution yielded a prevalence of 27% (Cohen's Kappa 0.44, 95% CI 0.23-0.65). There was no correlation in microvascular resistance between techniques (r = 0.17, 95% CI -0.04 to 0.36, p = 0.104). The adjustment of IMR by vessel volume significantly increased the agreement with absolute microvascular resistance derived from continuous thermodilution (r = 0.48, 95% CI 0.31-0.63, p < 0.001). CONCLUSIONS: In patients with ANOCA, invasive methods based on coronary thermodilution yielded conflicting results for the assessment of CMD. Adjusting IMR with vessel volume improved the agreement with continuous thermodilution for the assessment of microvascular resistance. These findings strongly suggest the importance of considering vessel volume when interpreting bolus thermodilution assessment.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Circulação Coronária , Vasos Coronários , Microcirculação , Valor Preditivo dos Testes , Termodiluição , Resistência Vascular , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Vasos Coronários/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/diagnóstico por imagem , Reprodutibilidade dos Testes
3.
Herz ; 49(1): 50-59, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37439804

RESUMO

BACKGROUND: Invasive cardiac output (CO) is measured with the thermodilution (TD) or the indirect Fick method (iFM) in right heart catheterization (RHC). The iFM estimates CO using approximation formulas for oxygen consumption ([Formula: see text]O2), but there are significant discrepancies (> 20%) between both methods. Although regularly applied, the formula proposed by Krakau has not been validated. We compared the CO discrepancies between the Krakau formula with the reference (TD) and three established formulas and investigated whether alterations assessed in cardiac magnetic resonance imaging (CMR) determined the extent of the deviations. METHODS: This retrospective study included 188 patients aged 63 ± 14 years (30% women) receiving both CMR and RHC. The CO was measured with TD or with the iFM using the formulas by Krakau, LaFarge, Dehmer, and Bergstra for [Formula: see text]O2 estimation (iFM-K/-L/-D/-B). Percentage errors were calculated as twice the standard deviation of the difference between two CO methods divided by their means; a cut-off of < 30% was regarded as acceptable. The iFM and TD-derived CO ratio was built, and deviations > 20% were counted. Logistic regression analyses were performed to identify determinants of a deviation of > 20%. RESULTS: The TD-derived CO (5.5 ± 1.7 L/min) was significantly different from all iFM (K: 4.8 ± 1.6, L: 4.3 ± 1.6; D: 4.8 ± 1.5 L/min; B: 5.4 ± 1.8 L/min all p < 0.05). The iFM-K-CO differed from all methods (p < 0.001) except iFM­D (p = 0.19). Percentage errors between TD-CO and iFM-K/-L/-D/-B were all beyond the acceptance limit (44/45/44/43%), while percentage errors between iFM­K and other iFM were all < 16%. None of the parameters measured in CMR was predictive of a discrepancy of > 20% between both methods. CONCLUSION: The Krakau formula was comparable to other iFM in estimating CO levels, but none showed satisfactory agreement with the TD method. Improved derivation cohorts for [Formula: see text]O2 estimation are needed that better reflect today's patients undergoing RHC.


Assuntos
Cateterismo Cardíaco , Termodiluição , Humanos , Feminino , Masculino , Estudos Retrospectivos , Débito Cardíaco , Consumo de Oxigênio
4.
Pediatr Cardiol ; 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38762577

RESUMO

Cardiac index (CI) may be derived from the Fick method, using measured or estimated oxygen consumption (VO2), or from thermodilution. In children, LaFarge VO2 estimates correlate poorly with measured VO2 values. In a large adult cohort, there was only modest correlation between estimated Fick CI (eFick CI) and thermodilution CI (TDCI). We evaluated the extent of agreement between eFick CI using LaFarge estimates of VO2 and TDCI in a pediatric cohort. A retrospective, single-center chart review of patients 3-18 years of age who underwent cardiac catheterization with documented eFick CI and TDCI from 2004 to 2020 included 201 catheterizations from 161 unique patients. The mean patient age at catheterization was 12.2y (SD 4.4y). The most frequent diagnosis was cardiomyopathy, followed by congenital heart disease and pulmonary hypertension. TDCI and eFick CI differed by > 20% in 49% of catheterizations. eFick CI systematically exceeded TDCI by a mean percentage difference of 24% (SD 31%). Higher mean CI ((eFick CI + TDCI)/2) and older age were predictive of greater percent difference between eFick CI and TDCI. For each increase in mean CI by 1.0 L/min/m2, the expected percent difference in CI increased by 9.9% (p < 0.001). In pediatric patients undergoing cardiac catheterization, eFick CI with LaFarge VO2 systematically exceeds TDCI. The difference between methods is frequently > 20%, which may have clinically significant implications. Discrepancies between eFick CI and TDCI increase at higher mean CI.

5.
J Card Fail ; 29(10): 1369-1379, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37105397

RESUMO

BACKGROUND: The current Impella cardiopulmonary (CP) pump, used for mechanical circulatory support in patients with cardiogenic shock (CS), cannot assess native cardiac output (CO) and left ventricular (LV) volumes. These data are valuable in facilitating device management and weaning. Admittance technology allows for accurate assessment of cardiac chamber volumes. OBJECTIVES: This study tested the ability to engineer admittance electrodes onto an existing Impella CP pump to assess total and native CO as well as LV chamber volumes in an instantaneous manner. METHODS: Impella CP pumps were fitted with 4 admittance electrodes and were placed in the LVs of adult swine (n = 9) that were subjected to 3 different hemodynamic conditions, including Impella CP speed adjustments, administration of escalating doses of dobutamine and microsphere injections into the left main artery to result in cardiac injury. CO, according to admittance electrodes, was calculated from LV volumes and heart rate. In addition, CO was calculated in each instance via thermodilution, continuous CO measurement, the Fick principle, and aortic velocity-time integral by means of echocardiography. RESULTS: Modified Impella CP pumps were placed in swine LVs successfully. CO, as determined by admittance electrodes, was similar by trend to other methods of CO assessment. It was corrected for pump speed to calculate native CO, and calculated LV chamber volumes trended as expected in each experimental protocol. CONCLUSIONS: We report, for the first time, that an Impella CP pump can be fitted with admittance electrodes and used to determine total and native CO in various hemodynamic situations. CONDENSED ABSTRACT: Transvalvular mechanical circulatory support devices such as the Impella CP do not have the ability to provide real-time information on native cardiac output (CO) and left ventricular (LV) volumes. This information is critical in device management and in weaning in patients with cardiogenic shock. We demonstrate, for the first time, that Impella CP pumps coupled with admittance electrodes are able to determine native CO and LV chamber volumes in multiple hemodynamic situations such as Impella pump speed adjustments, escalating dobutamine administration and cardiac injury from microsphere injection.

6.
Crit Care ; 27(1): 201, 2023 05 26.
Artigo em Inglês | MEDLINE | ID: mdl-37237287

RESUMO

BACKGROUND: A quantitative assessment of pulmonary edema is important because the clinical severity can range from mild impairment to life threatening. A quantitative surrogate measure, although invasive, for pulmonary edema is the extravascular lung water index (EVLWI) extracted from the transpulmonary thermodilution (TPTD). Severity of edema from chest X-rays, to date is based on the subjective classification of radiologists. In this work, we use machine learning to quantitatively predict the severity of pulmonary edema from chest radiography. METHODS: We retrospectively included 471 X-rays from 431 patients who underwent chest radiography and TPTD measurement within 24 h at our intensive care unit. The EVLWI extracted from the TPTD was used as a quantitative measure for pulmonary edema. We used a deep learning approach and binned the data into two, three, four and five classes increasing the resolution of the EVLWI prediction from the X-rays. RESULTS: The accuracy, area under the receiver operating characteristic curve (AUROC) and Mathews correlation coefficient (MCC) in the binary classification models (EVLWI < 15, ≥ 15) were 0.93 (accuracy), 0.98 (AUROC) and 0.86(MCC). In the three multiclass models, the accuracy ranged between 0.90 and 0.95, the AUROC between 0.97 and 0.99 and the MCC between 0.86 and 0.92. CONCLUSION: Deep learning can quantify pulmonary edema as measured by EVLWI with high accuracy.


Assuntos
Aprendizado Profundo , Edema Pulmonar , Humanos , Edema Pulmonar/diagnóstico por imagem , Edema Pulmonar/etiologia , Raios X , Estudos Retrospectivos , Água Extravascular Pulmonar/diagnóstico por imagem , Radiografia , Termodiluição
7.
Br J Anaesth ; 131(6): 971-974, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37714751

RESUMO

Flow-directed, balloon-tipped pulmonary artery catheters allow measuring cardiac output and other haemodynamic variables including intracardiac pressures. We propose classifying pulmonary artery catheters by generations and specifying additional measurement modalities. Based on the method used to measure cardiac output, pulmonary artery catheters can be classified into three generations: first-generation using intermittent pulmonary artery thermodilution; second-generation using a thermal filament for automated pulmonary artery thermodilution; and third-generation combining thermal filament-based automated pulmonary artery thermodilution and pulmonary artery pulse wave analysis. Each of these pulmonary artery catheter generations can include additional measurements, such as continuous mixed venous oxygen saturation, right ventricular ejection fraction and end-diastolic volume, and right ventricular pressure. This classification should help define indications for pulmonary artery catheters in clinical practice and research.


Assuntos
Artéria Pulmonar , Função Ventricular Direita , Humanos , Volume Sistólico , Cateterismo de Swan-Ganz , Débito Cardíaco , Termodiluição/métodos , Catéteres
8.
J Intensive Care Med ; 38(8): 717-726, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36872888

RESUMO

Introduction: Septic shock is associated with high mortality and hemodynamic impairment. The use of corticoids is a common therapeutic tool in critically ill patients. However, data on the mechanisms and prognostic ability of hemodynamic improvement by adjunctive steroids are rare. This study primarily aimed to evaluate short-term effects of hydrocortisone therapy on catecholamine requirement and hemodynamics derived from transpulmonary thermodilution (TPTD) in 30 critically ill patients with septic shock and a 28 days mortality rate of 50%. Methods: Hydrocortisone was administered with an intravenous bolus of 200 mg, followed by a continuous infusion of 200 mg per 24 h. Hemodynamic assessment was performed immediately before as well as 2, 8, 16, and 24 h after the initiation of corticoids. For primary endpoint analysis, we evaluated the impact of hydrocortisone on vasopressor dependency index (VDI) and cardiac power index (CPI). Results: Adjunctive hydrocortisone induced significant decreases of VDI from 0.41 (0.29-0.49) mmHg-1 at baseline to 0.35 (0.25-0.46) after 2 h (P < .001), 0.24 (0.12-0.35) after 8 h (P < .001), 0.18 (0.09-0.24) after 16 h (P < .001) and 0.11 (0.06-0.20) mmHg-1 after 24 h (P < .001). In parallel, we found an improvement in CPI from 0.63 (0.50-0.83) W/m2 at baseline to 0.68 (0.54-0.85) after 2 h (P = .208), 0.71 (0.60-0.90) after 8 h (P = .033), 0.82 (0.6-0.98) after 16 h (P = .004) and 0.90 (0.67-1.07) W/m2 after 24 h (P < .001). Our analyses revealed a significant reduction in noradrenaline requirement in parallel with a moderate increase in mean arterial pressure, systemic vascular resistance index, and cardiac index. As a secondary endpoint, our results showed a significant decrease in lung water parameters. Moreover, changes in CPI (ΔCPI) and VDI (ΔVDI) after 24 h of hydrocortisone therapy revealed accurate prognostic ability to predict 28 days mortality (AUC = 0.802 vs 0.769). Conclusion: Adjunctive hydrocortisone leads to a rapid decrease in catecholamine requirement and a substantial circulatory improvement in critically ill patients with septic shock.


Assuntos
Choque Séptico , Humanos , Hidrocortisona/uso terapêutico , Termodiluição/métodos , Estado Terminal/terapia , Hemodinâmica , Norepinefrina , Vasoconstritores/uso terapêutico , Vasoconstritores/farmacologia
9.
Heart Vessels ; 38(3): 341-347, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36181530

RESUMO

The pulmonary artery catheter (PAC)-despite its invasiveness-remains the gold standard for cardiac output (CO) monitoring. The FloTrac system, a less invasive hemodynamic monitor has been developed, which estimates CO using arterial pressure waveform analysis without external calibration. Recently, an upgraded version of FloTrac system with improved algorithm to follow changes in vascular resistance was introduced into the market. The aim of this study was to assess the reliability of the CO estimated from the fourth-generation FloTrac/EV1000 system (COFT) compared to that measured with PAC using the thermodilution method (COPAC) during robotic-assisted off-pump coronary artery bypass (OPCAB) surgery. COFT and COPAC were obtained simultaneously at 4 predefined time points during robotic-assisted OPCAB: 5 min after the induction of general anesthesia (T1), after starting one-lung ventilation (T2), after capnothorax (T3), and after mini-thoracotomy was performed (T4). The agreement of data was investigated by Bland-Altman analysis. Thirty-four patients were initially enrolled. After exclusion, 32 patients and a total of 128 paired CO measurements were obtained. The overall bias was 1.46 L/min, the 95% limits of agreements were - 3.40 to 6.33 L/min, and the percentage error was 72.98%. Regression analysis of the systemic vascular resistance index (SVRI) and the bias between COPAC and COFT showed that the bias was moderately correlated with the SVRI (r2 = 0.43; p < 0.0001). Despite a software upgrade, the reliability of the fourth-generation FloTrac/EV1000™ system during robotic-assisted OPCAB to estimate CO was not acceptable, especially in patients with low SVRI.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea , Procedimentos Cirúrgicos Robóticos , Humanos , Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Reprodutibilidade dos Testes , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Artéria Pulmonar/cirurgia , Monitorização Intraoperatória/métodos , Débito Cardíaco , Termodiluição/métodos
10.
BMC Anesthesiol ; 23(1): 180, 2023 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-37231335

RESUMO

BACKGROUND: The new noninvasive Vitalstream (VS) continuous physiological monitor (Caretaker Medical LLC, Charlottesville, Virginia), allows continuous cardiac output by a low pump-inflated, finger cuff that pneumatically couples arterial pulsations via a pressure line to a pressure sensor for detection and analysis. Physiological data are communicated wirelessly to a tablet-based user interface via Bluetooth or Wi-Fi. We evaluated its performance against thermodilution cardiac output in patients undergoing cardiac surgery. METHODS: We compared the agreement between thermodilution cardiac output to that obtained by the continuous noninvasive system during cardiac surgery pre and post-cardiac bypass. Thermodilution cardiac output was performed routinely when clinically indicated by an iced saline cold injectate system. All comparisons between VS and TD/CCO data were post-processed. In order to match the VS CO readings to the averaged discrete TD bolus data, the averaged CO readings of the ten seconds of VS CO data points prior to a sequence of TD bolus injections was matched. Time alignment was based on the medical record time and the VS time-stamped data points. The accuracy against reference TD measurements was assessed via Bland-Altman analysis of the CO values and standard concordance analysis of the ΔCO values (with a 15% exclusion zone). RESULTS: Analysis of the data compared the accuracy of the matched measurement pairs of VS and TD/CCO VS absolute CO values with and without initial calibration to the discrete TD CO values, as well as the trending ability, i.e., ΔCO values of the VS physiological monitor compared to those of the reference. The results were comparable with other non-invasive as well as invasive technologies and Bland-Altman analyses showed high agreement between devices in a diverse patient population. The results are significant regarding the goal of expanding access to effective, wireless and readily implemented fluid management monitoring tools to hospital sections previously not covered because of the limitations of traditional technologies. CONCLUSION: This study demonstrated that the agreement between the VS CO and TD CO was clinically acceptable with a percent error (PE) of 34.5 to 38% with and without external calibration. The threshold for an acceptable agreement between the VS and TD was considered to be below 40% which is below the threshold recommended by others.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Humanos , Débito Cardíaco/fisiologia , Ponte de Artéria Coronária , Dedos , Artérias , Termodiluição/métodos , Reprodutibilidade dos Testes
11.
J Clin Monit Comput ; 37(4): 1095-1102, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37166694

RESUMO

Thermodilution is the gold standard for cardiac output measurement in critically ill patients. Its application in extracorporeal therapy is limited, as a portion of the thermal indicator is drawn into the extracorporeal circuit. The behaviour of thermodilution signals in extracorporeal circuits is unknown. We investigated thermodilution curves within a closed-circuit and assessed the impact of injection volume, flow and distance on the behaviour of the thermodilution signals and catheter constants. We injected 3, 5, 7 and 10 ml of thermal indicator into a heated closed circuit. Thermistors at distances of 40, 60, 80, and 100 cm from the injection port recorded the thermodilution signals (at flow settings of 0.5, 1, 1.5, and 2 L/min). Area under the curve (AUC), rise time, exponential decay and catheter constants were analysed. Linear mixed-effects models were used to evaluate the impact of circuit flow, distance and injection volume. Catheter positioning did not influence AUC (78 injections). Catheter constants were independent of flow, injection volume or distance to the injection port. The distance to the injection port increased peak temperature and rise time and decreased exponential time constant significantly. The distance to the injection port did not influence catheter constants, but the properties of the thermodilution signal itself. This may influence measurements that depend on the exponential decay of the thermodilution signal such as right ventricular ejection fraction.


Assuntos
Termodiluição , Função Ventricular Direita , Humanos , Volume Sistólico , Catéteres , Débito Cardíaco
12.
J Clin Monit Comput ; 37(2): 599-607, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36284041

RESUMO

In severe acute respiratory distress syndrome (ARDS), veno-venous extracorporeal membrane oxygenation (V-V ECMO) has been proposed as a therapeutic strategy to possibly reduce mortality. Transpulmonary thermodilution (TPTD) enables monitoring of the extravascular lung water index (EVLWI) and cardiac preload parameters such as intrathoracic blood volume index (ITBVI) in patients with ARDS, but it is not generally recommended during V-V ECMO. We hypothesized that the amount of extracorporeal blood flow (ECBF) influences the calculation of EVLWI and ITBVI due to recirculation of indicator, which affects the measurement of the mean transit time (MTt), the time between injection and passing of half the indicator, as well as downslope time (DSt), the exponential washout of the indicator. EVLWI and ITBVI were measured in 20 patients with severe ARDS managed with V-V ECMO at ECBF rates from 6 to 4 and 2 l/min with TPTD. MTt and DSt significantly decreased when ECBF was reduced, resulting in a decreased EVLWI (26.1 [22.8-33.8] ml/kg at 6 l/min ECBF vs 22.4 [15.3-31.6] ml/kg at 4 l/min ECBF, p < 0.001; and 13.2 [11.8-18.8] ml/kg at 2 l/min ECBF, p < 0.001) and increased ITBVI (840 [753-1062] ml/m2 at 6 l/min ECBF vs 886 [658-979] ml/m2 at 4 l/min ECBF, p < 0.001; and 955 [817-1140] ml/m2 at 2 l/min ECBF, p < 0.001). In patients with severe ARDS managed with V-V ECMO, increasing ECBF alters the thermodilution curve, resulting in unreliable measurements of EVLWI and ITBVI. German Clinical Trials Register (DRKS00021050). Registered 14/08/2018. https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00021050.


Assuntos
Oxigenação por Membrana Extracorpórea , Síndrome do Desconforto Respiratório , Humanos , Volume Sanguíneo , Água Extravascular Pulmonar , Estudos Prospectivos , Síndrome do Desconforto Respiratório/terapia , Termodiluição/métodos
13.
J Anesth ; 37(3): 394-400, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36905408

RESUMO

PURPOSE: The estimated continuous cardiac output (esCCO) system was recently developed as a noninvasive hemodynamic monitoring alternative to the thermodilution cardiac output (TDCO). However, the accuracy of continuous cardiac output measurements by the esCCO system compared to TDCO under different respiratory conditions remains unclear. This prospective study aimed to assess the clinical accuracy of the esCCO system by continuously measuring the esCCO and TDCO. METHODS: Forty patients who had undergone cardiac surgery with a pulmonary artery catheter were enrolled. We compared the esCCO with TDCO from mechanical ventilation to spontaneous respiration through extubation. Patients undergoing cardiac pacing during esCCO measurement, those receiving treatment with an intra-aortic balloon pump, and those with measurement errors or missing data were excluded. In total, 23 patients were included. Agreement between the esCCO and TDCO measurements was evaluated using Bland-Altman analysis with a 20 min moving average of the esCCO. RESULTS: The paired esCCO and TDCO measurements (939 points before extubation and 1112 points after extubation) were compared. The respective bias and standard deviation (SD) values were 0.13 L/min and 0.60 L/min before extubation, and - 0.48 L/min and 0.78 L/min after extubation. There was a significant difference in bias before and after extubation (P < 0.001); the SD before and after extubation was not significant (P = 0.315). The percentage errors were 25.1% before extubation and 29.6% after extubation, which is the criterion for acceptance of a new technique. CONCLUSION: The accuracy of the esCCO system is clinically acceptable to that of TDCO under mechanical ventilation and spontaneous respiration.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Humanos , Estudos Prospectivos , Monitorização Fisiológica/métodos , Débito Cardíaco , Termodiluição/métodos
14.
Clin Sci (Lond) ; 136(22): 1653-1656, 2022 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-36398719

RESUMO

Over 50 years ago, John Wahren and Lennart Jorfeldt published a manuscript in Clinical Science where they detailed a series of studies of leg blood flow during exercise. They used a novel approach to indicator dye dilution: continuous arterial infusions of dye using venous samples. This technique allowed them to describe for the first time the fundamental relationships between large muscle group exercise, muscle blood flow, and pulmonary and muscle oxygen uptake. They also defined mechanical efficiency, a key measurement of muscle function. This paper formed the basis for research into muscle blood flow and exercise in health and disease and continued to be cited by modern research. In this commentary, we describe the innovations they made, the key observations that came out of their results, and the importance of this manuscript to current research.


Assuntos
Perna (Membro) , Consumo de Oxigênio , Humanos , Consumo de Oxigênio/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Perna (Membro)/irrigação sanguínea , Hemodinâmica , Músculos/metabolismo
15.
Catheter Cardiovasc Interv ; 100(2): 199-206, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35723684

RESUMO

AIM: Microvascular resistance reserve (MRR) as derived from continuous intracoronary thermodilution specifically quantifies microvasculature function. As originally described, the technique necessitates reinstrumentation of the artery and manual reprogramming of the infusion pump when performing resting and hyperemic measurements. To simplify and to render this procedure operator-independent, we developed a fully automated method. The aim of the present study is to validate the automated procedure against the originally described one. METHODS AND RESULTS: For the automated procedure, an infusion pump was preprogrammed to allow paired resting-hyperemic thermodilution assessment without interruption. To validate the accuracy of this new approach, 20 automated measurements were compared to those obtained in the same vessels with conventional paired resting-hyperemic thermodilution measurements (i.e., with a sensor pullback at each infusion rate and manual reprogramming of the infusion pump).  A close correlation between the conventional and the automated measuring technique was found for resting flow (Qrest : r = 0.89, mean bias = 2.52; SD = 15.47), hyperemic flow (Qhyper : r = 0.88, mean bias = -2.65; SD = 27.96), resting microvascular resistance (Rµ-rest : r = 0.90, mean bias = 52.14; SD = 228.29), hyperemic microvascular resistance Rµ-hyper : r = 0.92, mean bias = 12.95; SD = 57.80), and MRR (MRR: r = 0.89, mean bias = 0.04, SD = 0.59).  Procedural time was significantly shorter with the automated method (5'25″ ± 1'23″ vs. 4'36″ ± 0'33″, p = 0.013). CONCLUSION: Continuous intracoronary thermodilution-derived measurements of absolute flow, absolute resistance, and MRR can be fully automated. This further shortens and simplifies the procedure when performing paired resting-hyperemic measurements.


Assuntos
Hiperemia , Termodiluição , Automação , Circulação Coronária , Vasos Coronários , Humanos , Microcirculação , Termodiluição/métodos , Resultado do Tratamento , Resistência Vascular
16.
Crit Care ; 26(1): 202, 2022 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-35794612

RESUMO

BACKGROUND: The prognostic value of extravascular lung water (EVLW) measured by transpulmonary thermodilution (TPTD) in critically ill patients is debated. We performed a systematic review and meta-analysis of studies assessing the effects of TPTD-estimated EVLW on mortality in critically ill patients. METHODS: Cohort studies published in English from Embase, MEDLINE, and the Cochrane Database of Systematic Reviews from 1960 to 1 June 2021 were systematically searched. From eligible studies, the values of the odds ratio (OR) of EVLW as a risk factor for mortality, and the value of EVLW in survivors and non-survivors were extracted. Pooled OR were calculated from available studies. Mean differences and standard deviation of the EVLW between survivors and non-survivors were calculated. A random effects model was computed on the weighted mean differences across the two groups to estimate the pooled size effect. Subgroup analyses were performed to explore the possible sources of heterogeneity. RESULTS: Of the 18 studies included (1296 patients), OR could be extracted from 11 studies including 905 patients (464 survivors vs. 441 non-survivors), and 17 studies reported EVLW values of survivors and non-survivors, including 1246 patients (680 survivors vs. 566 non-survivors). The pooled OR of EVLW for mortality from eleven studies was 1.69 (95% confidence interval (CI) [1.22; 2.34], p < 0.0015). EVLW was significantly lower in survivors than non-survivors, with a mean difference of -4.97 mL/kg (95% CI [-6.54; -3.41], p < 0.001). The results regarding OR and mean differences were consistent in subgroup analyses. CONCLUSIONS: The value of EVLW measured by TPTD is associated with mortality in critically ill patients and is significantly higher in non-survivors than in survivors. This finding may also be interpreted as an indirect confirmation of the reliability of TPTD for estimating EVLW at the bedside. Nevertheless, our results should be considered cautiously due to the high risk of bias of many studies included in the meta-analysis and the low rating of certainty of evidence. Trial registration the study protocol was prospectively registered on PROSPERO: CRD42019126985.


Assuntos
Estado Terminal , Água Extravascular Pulmonar , Estado Terminal/mortalidade , Humanos , Prognóstico , Reprodutibilidade dos Testes , Termodiluição/métodos
17.
J Intensive Care Med ; 37(1): 21-31, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33148110

RESUMO

INTRODUCTION: Visualization of B-lines via lung ultrasound provides a non-invasive estimation of pulmonary hydration. Extravascular lung water index (EVLWI) and pulmonary vascular permeability index (PVPI) assessed by transpulmonary thermodilution (TPTD) represent the most validated parameters of lung water and alveolocapillary permeability, but measurement is invasive and expensive. This study aimed to compare the correlations of B-lines scores from extensive 28-sector and simplified 4-sector chest scan with EVLWI and PVPI derived from TPTD in the setting of intensive care unit (primary endpoint). METHODS: We performed scoring of 28-sector and 4-sector B-Lines in 50 critically ill patients. TPTD was carried out with the PiCCO-2-device (Pulsion Medical Systems SE, Maquet Getinge Group). Median time exposure for ultrasound procedure was 12 minutes for 28-sector and 4 minutes for 4-sector scan. RESULTS: Primarily, we found close correlations of 28-sector as well as 4-sector B-Lines scores with EVLWI (R2 = 0.895 vs. R2 = 0.880) and PVPI (R2 = 0.760 vs. R2 = 0.742). Both B-lines scores showed high accuracy to identify patients with specific levels of EVLWI and PVPI. The extensive 28-sector B-lines score revealed a moderate advantage compared to simplified 4-sector scan in detecting a normal EVLWI ≤ 7 (28-sector scan: sensitivity = 81.8%, specificity = 94.9%, AUC = 0.939 versus 4-sector scan: sensitivity = 81.8%, specificity = 82.1%, AUC = 0.902). Both protocols were approximately equivalent in prediction of lung edema with EVLWI ≥ 10 (28-sector scan: sensitivity = 88.9%, specificity = 95.7%, AUC = 0.977 versus 4-sector scan: sensitivity = 81.5%, specificity = 91.3%, AUC = 0.958) or severe pulmonary edema with EVLWI ≥ 15 (28-sector scan: sensitivity = 91.7%, specificity = 97.4%, AUC = 0.995 versus 4-sector scan: sensitivity = 91.7%, specificity = 92.1%, AUC = 0.978). As secondary endpoints, our evaluations resulted in significant associations of 28-sector as well as simplified 4-sector B-Lines score with parameters of respiratory function. CONCLUSION: Both B-line protocols provide accurate non-invasive evaluation of lung water in critically ill patients. The 28-sector scan offers a marginal advantage in prediction of pulmonary edema, but needs substantially more time than 4-sector scan.


Assuntos
Água Extravascular Pulmonar , Edema Pulmonar , Estado Terminal , Água Extravascular Pulmonar/diagnóstico por imagem , Humanos , Pulmão/diagnóstico por imagem , Edema Pulmonar/diagnóstico por imagem , Termodiluição
18.
BMC Anesthesiol ; 22(1): 277, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36050640

RESUMO

BACKGROUND: Although the use of vasopressors to maintain haemodynamic goals after acute spinal cord injury (SCI) is still recommended, evidence regarding the target values and possible risks of this practice is limited, and data on haemodynamic parameters unaffected by catecholamines are rare. In this pilot study, we show the haemodynamic profile of patients with acute SCI mainly unaffected by vasopressor use and other factors that influence the cardiovascular system. METHODS: From March 2018 to March 2020, we conducted a prospective, single-centre pilot study of 30 patients with acute SCI. Factors that could affect the cardiocirculatory system other than SCI (sepsis, pre-existing heart disease or multiple trauma) led to exclusion. A total of 417 measurements were performed using the PiCCO™ system. RESULTS: The mean systemic vascular resistance index (SVRI, 1447.23 ± 324.71 dyn*s*cm-5*m2), mean central venous pressure (CVP, 10.69 ± 3.16) and mean global end-diastolic volume index (GEDVI, 801.79 ± 158.95 ml/m2) deviated from the reference range, while the mean cardiac index (CI), mean stroke volume index (SVI), mean arterial pressure (MAP), and mean heart rate (HR) were within the reference range, as indicated in the literature. A mixed model analysis showed a significant negative relationship between norepinephrine treatment and MAP (83.97 vs. 73.69 mmHg, p < 0.001), SVRI (1463.40 vs. 1332.14 dyn*s*cm-5*m2, p = 0.001) and GEDVI (808.89 vs. 759.39 ml/m2, p = 0.001). CONCLUSION: These findings could lead to an adaptation of the target range for SVRI and MAP in patients with acute SCI and therefore reduce the use of vasopressors.


Assuntos
Monitorização Hemodinâmica , Traumatismos da Medula Espinal , Débito Cardíaco , Hemodinâmica , Humanos , Projetos Piloto , Estudos Prospectivos
19.
J Cardiothorac Vasc Anesth ; 36(8 Pt A): 2385-2392, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34895834

RESUMO

OBJECTIVE: Lung ultrasound (LUS) is a promising bedside modality for the estimation of extravascular lung water index (EVLWI), but has not been validated against objective measures in children. This study aimed to investigate the correlation of LUS B-line scoring with EVLWI, thresholds indicating elevated EVLWI, and its outcome following pediatric cardiac surgery. DESIGN: Prospective observational study. SETTING: Cardiothoracic surgical intensive care unit in a tertiary care teaching hospital. PARTICIPANTS: Children younger than 12 years undergoing elective complete surgical correction of cyanotic or acyanotic congenital heart disease (Aristotle score ≤9), excluding neonates, those weighing <3.5 kg, and those with thoracic deformities, pulmonary pathology, and hemodynamic instability. INTERVENTIONS: Extravascular lung water index measurement by transpulmonary thermodilution, along with concurrent LUS B-line and Chest-X ray (CXR) scoring. MEASUREMENTS AND MAIN RESULTS: LUS B-line score had a moderate correlation with EVLWI (Pearson's correlation coefficient 0.57; 95% CI 0.44-0.69). LUS B-line scores showed acceptable discrimination only for higher thresholds of EVLWI (sensitivity 82% and 79%, respectively, for EVLWI >20 mL/kg v sensitivity and specificity 57% and 80% for EVLWI >10 mL/kg). Age, body surface area, vasoactive-inotropic score (VIS), chest X-ray score, and EVLWI but not LUS B-line score were significant predictors for duration of mechanical ventilation in this cohort. CONCLUSIONS: LUS B-line scoring has limited utility in semiquantitative estimation of EVLWI at lower thresholds of EVLWI in pediatric cardiac surgical patients. It may have better discrimination and acceptable sensitivity and specificity at higher thresholds of EVLWI. Contrasting with multiple reports of clinical utility, these results call for wider evaluation of LUS and its clinical modifiers like age, pathology, and pretest probability in estimation of EVLWI.


Assuntos
Água Extravascular Pulmonar , Termodiluição , Criança , Água Extravascular Pulmonar/diagnóstico por imagem , Humanos , Recém-Nascido , Unidades de Terapia Intensiva , Pulmão/irrigação sanguínea , Pulmão/diagnóstico por imagem , Estudos Prospectivos , Termodiluição/métodos
20.
J Clin Monit Comput ; 36(1): 141-145, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33398546

RESUMO

Thermodilution cardiac output monitoring, using a thermistor-tipped intravascular catheter, is used in critically ill patients to guide hemodynamic therapy. Often, these patients also need magnetic resonance imaging (MRI) for diagnostic or prognostic reasons. As thermodilution catheters contain metal, they are considered MRI-unsafe and advised to be removed prior to investigation. However, removal and replacement of the catheter carries risks of bleeding, perforation and infection. This research is an in vitro safety assessment of the PiCCO™ thermodilution catheter during 3 T Magnetic Resonance Imaging (3T-MRI).  In a 3T-MRI environment, three different PiCCO™ catheter sizes were investigated in an agarose-gel, tissue mimicking phantom. Two temperature probes measured radiofrequency-induced heating; one at the catheter tip and one at a reference point. Magnetically induced catheter dislocation was assessed by visual observation as well as by analysis of the tomographic images. For all tested catheters, the highest measured temperature increase was 0.2 °C at the center of the bore and 0.3 °C under "worst-case" setting for the tested MRI pulse sequences. No magnetically induced catheter displacements were observed. Under the tested circumstances, no heating or dislocation of the PiCCO™ catheter was observed in a tissue mimicking phantom during 3T-MRI. Leaving the catheter in the critically ill patient during MRI investigation might pose a lower risk of complications than catheter removal and replacement.


Assuntos
Estado Terminal , Termodiluição , Débito Cardíaco , Catéteres , Humanos , Imageamento por Ressonância Magnética , Termodiluição/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA