Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 51(2): 568-580, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37792025

RESUMO

PURPOSE: Standardized uptake value (SUV) has been prevalently used to measure [68 Ga]Ga-PSMA-11 activity in prostate cancer, but it is susceptible to multiple factors. Parametric imaging allows for absolute quantification of tracer uptake and provides a better diagnostic accuracy that is crucial for lesion detection. However, the clinical significance of total-body parametric imaging of [68 Ga]Ga-PSMA-11 remains to be fully assessed. Therefore, the aim of our study is to delve into the diagnostic implications of total-body parametric imaging of [68 Ga]Ga-PSMA-11 PET/CT for patients with prostate cancer. METHODS: Twenty prostate cancer patients were included and underwent a dynamic total-body [68 Ga]Ga-PSMA-11 PET/CT scan. An irreversible two-tissue compartment model (2T3k) was fitted for each tissue time-to-activity curve, and the net influx rate (Ki) was obtained. The image quality and semi-quantitative analysis of lesion-to-background ratio (LBR), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared between parametric images and SUV images. RESULTS: Kinetic modeling using 2T3k demonstrated favorable model fitting in both normal organs and lesions. All of the lesions detected on SUV images (55-60 min) could be detected on Ki images. The correlation between Ki, SUVmean, and SUVmax in both normal organs and pathological lesions was found to be positive and statistically significant. Conversely, a moderate positive correlations were found between Ki and K1 (R = 0.69, P < 0.001; R = 0.61, P < 0.001) and Ki and k3 (R = 0.69, P < 0.001; R = 0.62, P < 0.001), in normal organs and pathological lesions, respectively. Visual assessment in Ki images showed less image noise and higher lesions conspicuity compared to SUV images. Ki image-derived LBR, SNR, and CBR of pathological lesions including primary tumors (PTs), lymph node metastases (LNMs) and bone metastases (BMs), exhibited remarkably higher folds (1.4-3.6 folds) compared to those derived from SUV of corresponding lesions. CONCLUSIONS: Total-body parametric imaging of [68 Ga]Ga-PSMA-11 enhanced lesion contrast and improved lesion detectability compared to SUV images. This may potentially serve as an imaging biomarker and theranostic tool for precise diagnosis and treatment evaluation in prostate cancer patients.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Masculino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Radioisótopos de Gálio , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Ácido Edético
2.
J Nucl Med ; 65(5): 714-721, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38548347

RESUMO

The lungs are supplied by both the pulmonary arteries carrying deoxygenated blood originating from the right ventricle and the bronchial arteries carrying oxygenated blood downstream from the left ventricle. However, this effect of dual blood supply has never been investigated using PET, partially because the temporal resolution of conventional dynamic PET scans is limited. The advent of PET scanners with a long axial field of view, such as the uEXPLORER total-body PET/CT system, permits dynamic imaging with high temporal resolution (HTR). In this work, we modeled the dual-blood input function (DBIF) and studied its impact on the kinetic quantification of normal lung tissue and lung tumors using HTR dynamic PET imaging. Methods: Thirteen healthy subjects and 6 cancer subjects with lung tumors underwent a dynamic 18F-FDG scan with the uEXPLORER for 1 h. Data were reconstructed into dynamic frames of 1 s in the early phase. Regional time-activity curves of lung tissue and tumors were analyzed using a 2-tissue compartmental model with 3 different input functions: the right ventricle input function, left ventricle input function, and proposed DBIF, all with time delay and dispersion corrections. These models were compared for time-activity curve fitting quality using the corrected Akaike information criterion and for differentiating lung tumors from lung tissue using the Mann-Whitney U test. Voxelwise multiparametric images by the DBIF model were further generated to verify the regional kinetic analysis. Results: The effect of dual blood supply was pronounced in the high-temporal-resolution time-activity curves of lung tumors. The DBIF model achieved better time-activity curve fitting than the other 2 single-input models according to the corrected Akaike information criterion. The estimated fraction of left ventricle input was low in normal lung tissue of healthy subjects but much higher in lung tumors (∼0.04 vs. ∼0.3, P < 0.0003). The DBIF model also showed better robustness in the difference in 18F-FDG net influx rate [Formula: see text] and delivery rate [Formula: see text] between lung tumors and normal lung tissue. Multiparametric imaging with the DBIF model further confirmed the differences in tracer kinetics between normal lung tissue and lung tumors. Conclusion: The effect of dual blood supply in the lungs was demonstrated using HTR dynamic imaging and compartmental modeling with the proposed DBIF model. The effect was small in lung tissue but nonnegligible in lung tumors. HTR dynamic imaging with total-body PET can offer a sensitive tool for investigating lung diseases.


Assuntos
Neoplasias Pulmonares , Tomografia por Emissão de Pósitrons , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/metabolismo , Masculino , Feminino , Pessoa de Meia-Idade , Cinética , Tomografia por Emissão de Pósitrons/métodos , Modelos Biológicos , Adulto , Fluordesoxiglucose F18 , Idoso , Imagem Corporal Total , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Processamento de Imagem Assistida por Computador , Fatores de Tempo , Compostos Radiofarmacêuticos/farmacocinética
3.
Med Phys ; 50(4): 2121-2134, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35950784

RESUMO

BACKGROUND: Total-body dynamic positron emission tomography (dPET) imaging using 18 F-fluorodeoxyglucose (18 F-FDG) has received widespread attention in clinical oncology. However, the conventionally required scan duration of approximately 1 h seriously limits the application and promotion of this imaging technique. In this study, we investigated the possibility and feasibility of shortening the total-body dynamic scan duration to 30 min post-injection (PI) with the help of a novel Patlak data processing algorithm for accurate Ki estimations of tumor lesions. METHODS: Total-body dPET images acquired by uEXPLORER (United Imaging Healthcare Inc.) using 18 F-FDG of 15 patients with different tumor types were analyzed in this study. Dynamic images were reconstructed into 25 frames with a specific temporal dividing protocol for the scan data acquired 1 h PI. Patlak analysis-based Ki parametric imaging was conducted based on the imaging data corresponding to the first 30 min PI, during which a Patlak data processing method based on cubic Hermite interpolation was applied. The resultant Ki images acquired by 30 min dynamic PET data and the standard 1 h Ki images were compared in terms of visual imaging effect, region signal-to-noise ratio, and Ki estimation accuracy to evaluate the performance of the proposed Ki imaging method with a shortened scan duration. RESULTS: With the help of Patlak data processing, acceptable Ki parametric images were obtained from dynamic PET data acquired with a scan duration of 30 min PI. Compared with Ki images obtained from unprocessed Patlak data, the resulting images from the proposed method performed better in terms of noise reduction. Moreover, Bland-Altman plot and Pearson correlation coefficient analysis showed that that 30 min Ki images obtained from the processed Patlak data had higher accuracy for tumor lesions. CONCLUSION: Satisfactory Ki parametric images with high tumor accuracy can be acquired from dynamic imaging data corresponding to the first 30 min PI. Patlak data processing can help achieve higher Ki imaging quality and higher accuracy regarding tumor lesion Ki values. Clinically, it is possible to shorten the dynamic scan duration of 18 F-FDG PET to 30 min to acquire an accurate tumor Ki and further effective tumor detection with uEXPLORER scanners.


Assuntos
Fluordesoxiglucose F18 , Neoplasias , Humanos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Imagem Corporal Total/métodos , Neoplasias/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos
4.
J Nucl Med ; 64(11): 1821-1830, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37591539

RESUMO

Conventional whole-body static 18F-FDG PET imaging provides a semiquantitative evaluation of overall glucose metabolism without insight into the specific transport and metabolic steps. Here we demonstrate the ability of total-body multiparametric 18F-FDG PET to quantitatively evaluate glucose metabolism using macroparametric quantification and assess specific glucose delivery and phosphorylation processes using microparametric quantification for studying recovery from coronavirus disease 2019 (COVID-19). Methods: The study included 13 healthy subjects and 12 recovering COVID-19 subjects within 8 wk of confirmed diagnosis. Each subject had a 1-h dynamic 18F-FDG scan on the uEXPLORER total-body PET/CT system. Semiquantitative SUV and the SUV ratio relative to blood (SUVR) were calculated for different organs to measure glucose utilization. Tracer kinetic modeling was performed to quantify the microparametric blood-to-tissue 18F-FDG delivery rate [Formula: see text] and the phosphorylation rate k 3, as well as the macroparametric 18F-FDG net influx rate ([Formula: see text]). Statistical tests were performed to examine differences between healthy subjects and recovering COVID-19 subjects. The effect of COVID-19 vaccination was also investigated. Results: We detected no significant difference in lung SUV but significantly higher lung SUVR and [Formula: see text] in COVID-19 recovery, indicating improved sensitivity of kinetic quantification for detecting the difference in glucose metabolism. A significant difference was also observed in the lungs with the phosphorylation rate k 3 but not with [Formula: see text], which suggests that glucose phosphorylation, rather than glucose delivery, drives the observed difference of glucose metabolism. Meanwhile, there was no or little difference in bone marrow 18F-FDG metabolism measured with SUV, SUVR, and [Formula: see text] but a significantly higher bone marrow [Formula: see text] in the COVID-19 group, suggesting a difference in glucose delivery. Vaccinated COVID-19 subjects had a lower lung [Formula: see text] and a higher spleen [Formula: see text] than unvaccinated COVID-19 subjects. Conclusion: Higher lung glucose metabolism and bone marrow glucose delivery were observed with total-body multiparametric 18F-FDG PET in recovering COVID-19 subjects than in healthy subjects, implying continued inflammation during recovery. Vaccination demonstrated potential protection effects. Total-body multiparametric PET of 18F-FDG can provide a more sensitive tool and more insights than conventional whole-body static 18F-FDG imaging to evaluate metabolic changes in systemic diseases such as COVID-19.


Assuntos
COVID-19 , Fluordesoxiglucose F18 , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Vacinas contra COVID-19 , COVID-19/diagnóstico por imagem , Glucose , Tomografia por Emissão de Pósitrons/métodos
5.
J Nucl Med ; 64(6): 960-967, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36604180

RESUMO

Fibroblast activation protein inhibitor (FAPI) is an ideal diagnostic and therapeutic target in malignant tumors. However, the knowledge of kinetic modeling and parametric imaging of 68Ga-FAPI is limited. Purpose: The purpose of this study was to explore the pharmacokinetics of 68Ga-FAPI-04 PET/CT in pancreatic cancer and gastric cancer and to conduct parametric imaging of dynamic total-body data compared with SUV imaging. Methods: Dynamic total-body 68Ga-FAPI-04 PET/CT was performed on 13 patients. The lesion time-activity curves were fitted by 3-compartment models and multigraphical models. The kinetics parameters derived from the 2-tissue reversible compartment model (2T4K) and multigraphical models were analyzed. Parametric [Formula: see text] imaging was generated using the 2T4K and Logan models, and their performances were evaluated compared with SUV images. Results: 2T4K had the lowest Akaike information criterion value, and its fitting curves matched excellently with the origin time-activity curves. Visual assessment revealed that the [Formula: see text](2T4K) images and [Formula: see text](Logan with spatial constraint [SC]) images both showed less image noise and higher lesion conspicuity compared with SUV images. Objective image quality assessment demonstrated that parametric [Formula: see text](2T4K) images and parametric [Formula: see text](Logan with SC) images had a 5.0-fold and 5.0-fold higher average signal-to-noise ratio and 3.6-fold and 4.1-fold higher average contrast-to-noise ratio compared with conventional SUV images, respectively. In addition, no significant differences in signal-to-noise ratio and contrast-to-noise of pathologic lesions were observed between parametric [Formula: see text](2T4K) images and parametric [Formula: see text](Logan with SC) images (all P > 0.05). Conclusions: The 2T4K model was the preferred compartment model. Total-body parametric imaging of 68Ga-FAPI-04 PET yielded superior quantification beyond SUV with enhanced lesion contrast, which may serve as a promising imaging method to make an early diagnosis, to better reflect tumor characterization, or to allow evaluation of treatment response. [Formula: see text](2T4K) images are comparable in image quality and consistent to [Formula: see text](Logan with SC) images in lesions conspicuity; however, [Formula: see text](Logan with SC) images presented an appealing alternative to [Formula: see text](2T4K) images because of their simplicity.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias Gástricas , Humanos , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos de Gálio , Neoplasias Gástricas/diagnóstico por imagem , Fluordesoxiglucose F18
6.
J Nucl Med ; 63(8): 1274-1281, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34795014

RESUMO

Quantitative dynamic PET with compartmental modeling has the potential to enable multiparametric imaging and more accurate quantification than static PET imaging. Conventional methods for parametric imaging commonly use a single kinetic model for all image voxels and neglect the heterogeneity of physiologic models, which can work well for single-organ parametric imaging but may significantly compromise total-body parametric imaging on a scanner with a long axial field of view. In this paper, we evaluate the necessity of voxelwise compartmental modeling strategies, including time delay correction (TDC) and model selection, for total-body multiparametric imaging. Methods: Ten subjects (5 patients with metastatic cancer and 5 healthy volunteers) were scanned on a total-body PET/CT system after injection of 370 MBq of 18F-FDG. Dynamic data were acquired for 60 min. Total-body parametric imaging was performed using 2 approaches. One was the conventional method that uses a single irreversible 2-tissue-compartment model with and without TDC. The second approach selects the best kinetic model from 3 candidate models for individual voxels. The differences between the 2 approaches were evaluated for parametric imaging of microkinetic parameters and the 18F-FDG net influx rate, KiResults: TDC had a nonnegligible effect on kinetic quantification of various organs and lesions. The effect was larger in lesions with a higher blood volume. Parametric imaging of Ki with the standard 2-tissue-compartment model introduced vascular-region artifacts, which were overcome by the voxelwise model selection strategy. Conclusion: The time delay and appropriate kinetic model vary in different organs and lesions. Modeling of the time delay of the blood input function and model selection improved total-body multiparametric imaging.


Assuntos
Fluordesoxiglucose F18 , Neoplasias , Algoritmos , Humanos , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons/métodos
7.
Ann Nucl Med ; 36(10): 887-896, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35857172

RESUMO

OBJECTIVE: To explore the feasibility of ultralow-activity 18F-FDG total-body dynamic PET imaging for clinical practice in patients with lung adenocarcinoma. METHODS: Eight of 18 patients were randomly injected with 18F-FDG with full activity (3.7 MBq/kg) for total-body dynamic PET imaging, while 10 received one-tenth activity (0.37 MBq/kg). The generated time-to-activity curves (TACs) according to the regions of interest (ROIs) were processed by PMOD through standard FDG two-tissue compartment model fitting. The kinetic constant rates (K1, K2, K3, and Ki), radiation dose, prompt counts, and data storage size were analysed between the full- and ultralow-activity groups. The SUVmax-Tumour/SUVmax-Liver and SUVmax-Tumour/SUVmax-Muscle on static PET images were also assessed. RESULTS: Each of the fitted models has a satisfactory goodness-of-fit with R2 greater than 0.9 except 3 (3/234) in ultralow-activity group, where one in pancreas (R2 = 0.851), another one in muscle (R2 = 0.868), and the third one in bone marrow (R2 = 0.895). All the fitted models in the full-activity group had a better goodness-of-fit than those in the ultralow-activity group. However, no significant differences were found in any of the kinetic metrics or image quality between the two groups except in the reduction of radiation dose and data storage size. CONCLUSIONS: The 10 × reduction of injected 18F-FDG could achieve comparable kinetic metrics and T/N ratios by total-body dynamic PET imaging in lung adenocarcinoma patients. Ultralow-activity total-body PET imaging is feasible for clinical practice in oncological patients without obesity, especially in dynamic PET scanning.


Assuntos
Adenocarcinoma de Pulmão , Neoplasias Pulmonares , Adenocarcinoma de Pulmão/diagnóstico por imagem , Estudos de Viabilidade , Fluordesoxiglucose F18 , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA