Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
BMC Vet Res ; 20(1): 145, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38641793

RESUMO

BACKGROUND: Human records describe pulmonary edema as a life-threatening complication of electric shock. Successful management requires prompt recognition and intensive care. However, in companion animals, electrocutions are rarely reported, even though domestic environments are full of electrical devices and there is always the possibility of accidental injury. Therefore, it is important for veterinarians to know more about this condition in order to achieve successful patient outcomes. CASE PRESENTATION: A 3-month-old male Labrador Retriever was presented with a history of transient loss of consciousness after chewing on a household electrical cord. On admission, the puppy showed an orthopneic position with moderate respiratory distress. Supplemental oxygen via nasal catheter was provided, but the patient showed marked worsening of respiratory status. Point-of-care ultrasound exams suggested neurogenic pulmonary edema due to electrical shock close to the central nervous system and increased B-lines without evidence of cardiac abnormalities. Mechanical ventilation of the patient was initiated using volume-controlled mode with a tidal volume of 9 to 15 ml/kg until reaching an end-tidal carbon dioxide ≤ 40 mm Hg, followed by a stepwise lung-recruitment maneuver in pressure-controlled mode with increases of the peak inspiratory pressure (15 to 20 cm H2O) and positive end-expiratory pressure (3 to 10 cm H2O) for 30 min, and return to volume-controlled mode with a tidal volume of 15 ml/kg until reaching a peripheral oxygen saturation ≥ 96%. Weaning from the ventilator was achieved in six hours, and the patient was discharged two days after admission without neurological or respiratory deficits. CONCLUSIONS: We present a rather unusual case of a neurogenic pulmonary edema subsequent to accidental electrocution in a dog. Timely diagnosis by ultrasound and mechanical ventilation settings are described. Our case highlights that pulmonary edema should be considered a potentially life-threatening complication of electrical shock in small animal emergency and critical care medicine.


Assuntos
Doenças do Cão , Traumatismos por Eletricidade , Edema Pulmonar , Síndrome do Desconforto Respiratório , Animais , Cães , Masculino , Doenças do Cão/etiologia , Doenças do Cão/terapia , Traumatismos por Eletricidade/complicações , Traumatismos por Eletricidade/terapia , Traumatismos por Eletricidade/veterinária , Pulmão , Edema Pulmonar/etiologia , Edema Pulmonar/terapia , Edema Pulmonar/veterinária , Respiração Artificial/veterinária , Síndrome do Desconforto Respiratório/veterinária
2.
Vet Radiol Ultrasound ; 55(3): 315-22, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24382172

RESUMO

Lung ultrasound is superior to lung auscultation and supine chest radiography for many respiratory conditions in human patients. Ultrasound diagnoses are based on easily learned patterns of sonographic findings and artifacts in standardized images. By applying the wet lung (ultrasound lung rockets or B-lines, representing interstitial edema) versus dry lung (A-lines with a glide sign) concept many respiratory conditions can be diagnosed or excluded. The ultrasound probe can be used as a visual stethoscope for the evaluation of human lungs because dry artifacts (A-lines with a glide sign) predominate over wet artifacts (ultrasound lung rockets or B-lines). However, the frequency and number of wet lung ultrasound artifacts in dogs with radiographically normal lungs is unknown. Thus, the primary objective was to determine the baseline frequency and number of ultrasound lung rockets in dogs without clinical signs of respiratory disease and with radiographically normal lung findings using an 8-view novel regionally based lung ultrasound examination called Vet BLUE. Frequency of ultrasound lung rockets were statistically compared based on signalment, body condition score, investigator, and reasons for radiography. Ten left-sided heart failure dogs were similarly enrolled. Overall frequency of ultrasound lung rockets was 11% (95% confidence interval, 6-19%) in dogs without respiratory disease versus 100% (95% confidence interval, 74-100%) in those with left-sided heart failure. The low frequency and number of ultrasound lung rockets observed in dogs without respiratory disease and with radiographically normal lungs suggests that Vet BLUE will be clinically useful for the identification of canine respiratory conditions.


Assuntos
Doenças do Cão/diagnóstico por imagem , Cães/anatomia & histologia , Insuficiência Cardíaca/veterinária , Pulmão/diagnóstico por imagem , Animais , Artefatos , Insuficiência Cardíaca/diagnóstico por imagem , Valores de Referência , Ultrassonografia
3.
Vet J ; 275: 105727, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34343710

RESUMO

Thoracic radiography (TR), the most common screening test for pulmonary metastases in dogs, can fail to detect small lesions <3 mm. Lung ultrasonography (LUS) is a widely available imaging modality capable of detecting peripheral nodules but is underutilized for this purpose. Thoracic computed tomography (CT) is the criterion standard for diagnosis of lung metastases and nodular disease but is less practical for a variety of reasons. We hypothesized that LUS would be more sensitive but less specific at detecting nodules consistent with metastatic pulmonary disease in dogs compared to TR, using CT as the criterion standard. This was a masked, single-center prospective study of 62 client-owned dogs evaluated for respiratory signs or pulmonary metastatic neoplasia screening using TR, LUS and CT. Dogs were included if metastatic pulmonary disease was a differential. All imaging modalities were scored as having nodules (yes/no) and other types of pathologic lesions were recorded. Sensitivity (Se), specificity (Sp) and positive (LR+) and negative likelihood ratios (LR-) were determined for TR and LUS. For TR, Se and Sp were 64% and 73%, and LR+ and LR- were 2.37 and 0.49, respectively. For LUS, Se and Sp were 60% and 65% and LR+ and LR- were 1.71 and 0.62, respectively. The results of the study indicate that LUS had a similar Se to TR, with both modalities missing nodules when used for screening. The low Sp and LR- suggests caution should be used when assuming TR and LUS rule out the presence of nodules.


Assuntos
Doenças do Cão/diagnóstico por imagem , Neoplasias Pulmonares/veterinária , Radiografia Torácica/veterinária , Ultrassonografia/veterinária , Animais , Cães , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/secundário , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/veterinária
4.
Vet Clin North Am Small Anim Pract ; 51(6): 1141-1151, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34521570

RESUMO

Lung ultrasound (LUS) has high sensitivity for the rapid and reliable diagnosis of pulmonary contusions (PC) in patients who have sustained trauma. LUS diagnosis of PC exceeds that of thoracic radiographs in multiple animal and human studies. The sonographer should understand potential caveats and confounding variables for proper diagnosis of PC with LUS. LUS does not replace conventional radiography or computed tomography, especially in the polytrauma patient. LUS should be used concurrently with other point-of-care ultrasound trauma protocols to rapidly optimize patient assessment before movement to the radiology suite.


Assuntos
Contusões , Pulmão , Animais , Contusões/veterinária , Humanos , Pulmão/diagnóstico por imagem , Radiografia , Tomografia Computadorizada por Raios X/veterinária , Ultrassonografia/veterinária
5.
Vet Clin North Am Small Anim Pract ; 50(6): 1445-1467, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32912606

RESUMO

Global Focused Assessment with Sonography for Trauma (FAST) and point-of-care ultrasonography carry the potential to screen for and monitor conditions rather than traditional means without ultrasonography. Advantages include being point of care, cageside, low impact, rapid, safe, and radiation sparing, and requiring no shaving and/or minimal patient restraint. Moreover, information is real time for free fluid and soft tissue abnormalities of the abdomen, heart, and lung, which are missed or only suspected by physical examination, basic blood and urine testing, and radiography. A standardized approach with recording of patient data is integral to a successful Global FAST program.


Assuntos
Doenças do Gato/diagnóstico por imagem , Doenças do Cão/diagnóstico por imagem , Hospitais Veterinários , Ultrassonografia/veterinária , Animais , Gatos , Cães , Serviço Hospitalar de Emergência , Unidades de Terapia Intensiva , Sistemas Automatizados de Assistência Junto ao Leito
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA