Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.630
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Annu Rev Biochem ; 92: 351-384, 2023 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-37068769

RESUMO

Thiolases are CoA-dependent enzymes that catalyze the thiolytic cleavage of 3-ketoacyl-CoA, as well as its reverse reaction, which is the thioester-dependent Claisen condensation reaction. Thiolases are dimers or tetramers (dimers of dimers). All thiolases have two reactive cysteines: (a) a nucleophilic cysteine, which forms a covalent intermediate, and (b) an acid/base cysteine. The best characterized thiolase is the Zoogloea ramigera thiolase, which is a bacterial biosynthetic thiolase belonging to the CT-thiolase subfamily. The thiolase active site is also characterized by two oxyanion holes, two active site waters, and four catalytic loops with characteristic amino acid sequence fingerprints. Three thiolase subfamilies can be identified, each characterized by a unique sequence fingerprint for one of their catalytic loops, which causes unique active site properties. Recent insights concerning the thiolase reaction mechanism, as obtained from recent structural studies, as well as from classical and recent enzymological studies, are addressed, and open questions are discussed.


Assuntos
Coenzima A , Cisteína , Coenzima A/química , Coenzima A/metabolismo , Cisteína/metabolismo , Modelos Moleculares , Acetil-CoA C-Acetiltransferase/química , Acetil-CoA C-Acetiltransferase/metabolismo , Domínio Catalítico
2.
Mol Cell ; 81(19): 3992-4007.e10, 2021 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-34562373

RESUMO

ParB-like CTPases mediate the segregation of bacterial chromosomes and low-copy number plasmids. They act as DNA-sliding clamps that are loaded at parS motifs in the centromere of target DNA molecules and spread laterally to form large nucleoprotein complexes serving as docking points for the DNA segregation machinery. Here, we solve crystal structures of ParB in the pre- and post-hydrolysis state and illuminate the catalytic mechanism of nucleotide hydrolysis. Moreover, we identify conformational changes that underlie the CTP- and parS-dependent closure of ParB clamps. The study of CTPase-deficient ParB variants reveals that CTP hydrolysis serves to limit the sliding time of ParB clamps and thus drives the establishment of a well-defined ParB diffusion gradient across the centromere whose dynamics are critical for DNA segregation. These findings clarify the role of the ParB CTPase cycle in partition complex assembly and function and thus advance our understanding of this prototypic CTP-dependent molecular switch.


Assuntos
Proteínas de Bactérias/metabolismo , Segregação de Cromossomos , Cromossomos Bacterianos , Citidina Trifosfato/metabolismo , DNA Bacteriano/metabolismo , Myxococcus xanthus/enzimologia , Proteínas de Bactérias/genética , Sítios de Ligação , Domínio Catalítico , Cristalografia por Raios X , DNA Bacteriano/genética , Regulação Bacteriana da Expressão Gênica , Hidrólise , Mutação , Myxococcus xanthus/genética , Conformação Proteica , Relação Estrutura-Atividade , Especificidade por Substrato , Fatores de Tempo
3.
J Pathol ; 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39056146

RESUMO

The CCL2-CCR2 axis is involved in lupus nephritis, however the precise roles in the mechanisms by which different pathological lesions develop after glomerular immune complex deposition remain elusive. Previously, we demonstrated that genetic CCR2 inhibition induced a histological switch from glomerular endocapillary hypercellularity to wire-loop lesions in murine lupus nephritis. This study aimed to clarify the CCL2-CCR2 axis-mediated cellular mechanism in the formation of these different pathological lesions. We injected MRL/lpr mouse-derived monoclonal IgG3 antibody-producing hybridomas, 2B11.3 or B1, into wild-type (WT) mice to selectively induce glomerular endocapillary hypercellularity or wire-loop lesions. The expression of chemokine and chemokine receptors was analyzed using RT-quantitative PCR and/or immunofluorescence. We found 2B11.3 caused glomerular endocapillary hypercellularity in WT mice with glomerular infiltration of larger numbers of CCR2-expressing macrophages and neutrophils phagocyting immune complex, whereas B1 induced wire-loop lesions. In glomerular endocapillary hypercellularity, CCL2 was identified as the ligand involved in the CCR2-positive cell infiltration; it was expressed by glomerular endothelial cells and macrophages. Notably, 2B11.3-induced glomerular endocapillary hypercellularity converted to wire-loop lesions with reduced glomerular macrophage and neutrophil infiltration in CCL2-deficient (Ccl2-/-) mice similarly observed in Ccr2-/- mice. Moreover, this histological conversion was also observed when both glomerular macrophage and neutrophil infiltration were inhibited in anti-Ly6G antibody-treated Ccr5-/- mice but not when only glomerular macrophage infiltration was inhibited in Ccr5-/- mice or when only glomerular neutrophil infiltration was inhibited in anti-Ly6G antibody-treated WT mice. In contrast, B1 injection caused wire-loop lesions in Ccl2-/- and Ccr2-/- mice, as observed in WT mice. Moreover, 2B11.3 induced CCL2 from glomerular endothelial cells to a larger extent than B1 when injected into Ccr2-/- mice. In conclusion, the CCL2-CCR2 axis determines whether glomerular endocapillary hypercellularity or wire-loop lesions develop by regulating glomerular infiltration of phagocytic cells: macrophages and neutrophils. © 2024 The Pathological Society of Great Britain and Ireland.

4.
Proc Natl Acad Sci U S A ; 119(6)2022 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-35105811

RESUMO

This paper reports the noncontact manipulation of free-falling cylindrical streams of liquid metals into unique shapes, such as levitated loops and squares. Such cylindrical streams form in aqueous media by electrochemically lowering the interfacial tension. The electrochemical reactions require an electrical current that flows through the streams, making them susceptible to the Lorentz force. Consequently, varying the position and shape of a magnetic field relative to the stream controls these forces. Moreover, the movement of the metal stream relative to the magnetic field induces significant forces arising from Lenz's law that cause the manipulated streams to levitate in unique shapes. The ability to control streams of liquid metals in a noncontact manner will enable strategies for shaping electronically conductive fluids for advanced manufacturing and dynamic electronic structures.

5.
Proc Natl Acad Sci U S A ; 119(6)2022 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-35115404

RESUMO

A critical spintronics challenge is to develop molecular wires that render efficiently spin-polarized currents. Interplanar torsional twisting, driven by chiral binucleating ligands in highly conjugated molecular wires, gives rise to large near-infrared rotational strengths. The large scalar product of the electric and magnetic dipole transition moments ([Formula: see text]), which are evident in the low-energy absorptive manifolds of these wires, makes possible enhanced chirality-induced spin selectivity-derived spin polarization. Magnetic-conductive atomic force microscopy experiments and spin-Hall devices demonstrate that these designs point the way to achieve high spin selectivity and large-magnitude spin currents in chiral materials.

6.
Microcirculation ; 31(6): e12871, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38805589

RESUMO

OBJECTIVE: This study aimed to determine nicotine's impact on receptor-mediated cyclic adenosine monophosphate (cAMP) synthesis in vascular smooth muscle (VSM). We hypothesize that nicotine impairs ß adrenergic-mediated cAMP signaling in VSM, leading to altered vascular reactivity. METHODS: The effects of nicotine on cAMP signaling and vascular function were systematically tested in aortic VSM cells and acutely isolated aortas from mice expressing the cAMP sensor TEpacVV (Camper), specifically in VSM (e.g., CamperSM). RESULTS: Isoproterenol (ISO)-induced ß-adrenergic production of cAMP in VSM was significantly reduced in cells from second-hand smoke (SHS)-exposed mice and cultured wild-type VSM treated with nicotine. The decrease in cAMP synthesis caused by nicotine was verified in freshly isolated arteries from a mouse that had cAMP sensor expression in VSM (e.g., CamperSM mouse). Functionally, the changes in cAMP signaling in response to nicotine hindered ISO-induced vasodilation, but this was reversed by immediate PDE3 inhibition. CONCLUSIONS: These results imply that nicotine alters VSM ß adrenergic-mediated cAMP signaling and vasodilation, which may contribute to the dysregulation of vascular reactivity and the development of vascular complications for nicotine-containing product users.


Assuntos
AMP Cíclico , Músculo Liso Vascular , Nicotina , Transdução de Sinais , Animais , Nicotina/farmacologia , AMP Cíclico/metabolismo , Camundongos , Músculo Liso Vascular/metabolismo , Músculo Liso Vascular/efeitos dos fármacos , Transdução de Sinais/efeitos dos fármacos , Vasodilatação/efeitos dos fármacos , Isoproterenol/farmacologia , Masculino , Aorta/metabolismo , Aorta/efeitos dos fármacos , Células Cultivadas
7.
Small ; : e2401565, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38745539

RESUMO

Stretchable strain sensors play a crucial role in intelligent wearable systems, serving as the interface between humans and environment by translating mechanical strains into electrical signals. Traditional fiber strain sensors with intrinsic uniform axial strain distribution face challenges in achieving high sensitivity and anisotropy. Moreover, existing micro/nano-structure designs often compromise stretchability and durability. To address these challenges, a novel approach of using 3D printing to fabricate MXene-based flexible sensors with tunable micro and macrostructures.  Poly(tetrafluoroethylene) (PTFE) as a pore-inducing agent is added into 3D printable inks to achieve controllable microstructural modifications. In addition to microstructure tuning, 3D printing is employed for macrostructural design modifications, guided by finite element modeling (FEM) simulations. As a result, the 3D printed sensors exhibit heightened sensitivity and anisotropy, making them suitable for tracking static and dynamic displacement changes. The proposed approach presents an efficient and economically viable solution for standardized large-scale production of advanced wire strain sensors.

8.
Small ; 20(13): e2308945, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37948432

RESUMO

The family of metal-free molecular perovskites, an emerging novel class of eco-friendly semiconductor, welcomes a new member with a unique 1D hexagonal perovskite structure. Lowering dimensionality at molecular level is a facile strategy for crystal structure conversion, optoelectronic property regulation, and device performance optimization. Herein, the study reports the design, synthesis, packing structure, and photophysical properties of the 1D metal-free molecular perovskite-related single crystal, rac-3APD-NH4I3(rac-3APD= racemic-3-Aminopiperidinium), that features a quantum wire structure formed by infinite chains of face-sharing NH4I6 octahedra, enabling strong quantum confinement with strongly self-trapped excited (STE) states to give efficient warm orange emission with a photoluminescence quantum yield (PLQY) as high as ≈41.6%. The study accordingly unveils its photoexcited carrier dynamics: rac-3APD-NH4I3 relaxes to STE state with a short lifetime of 10 ps but decays to ground state by emitting photons with a relatively longer lifetime of 560 ps. Additionally, strong quantum confinement effect is conducive to charge transport along the octahedral channels that enables the co-planar single-crystal X-ray detectors to achieve a sensitivity as high as 1556 µC Gyair -1 cm-2. This work demonstrates the first case of photoluminescence mechanism and photophysical dynamics of 1D metal-free perovskite-related semiconductor, as well as the promise for high-performance X-ray detector.

9.
Ann Surg Oncol ; 31(6): 3916-3925, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38472677

RESUMO

BACKGROUND: Wire localisation (WL) is the "gold standard" localisation technique for wide local excision (WLE) of non-palpable breast lesions but has disadvantages that have led to the development of wireless techniques. This study compared the cost-effectiveness of radar localisation (RL) to WL. METHODS: This was a single-institution study of 110 prospective patients with early-stage breast cancer undergoing WLE using RL with the SCOUT® Surgical Guidance System (2021-2023) compared with a cohort of 110 patients using WL. Margin status, re-excision rates, and surgery delays associated with preoperative localisation were compared. Costs from a third-party payer perspective in Australian dollars (AUD$) calculated by using microcosting, break-even point, and cost-utility analyses. RESULTS: A total of 110 WLEs using RL cost a total of AUD$402,281, in addition to the device cost of AUD$77,150. The average additional cost of a surgery delay was AUD$2318. Use of RL reduced the surgery delay rate by 10% (p = 0.029), preventing 11 delays with cost savings of AUD$25,496. No differences were identified in positive margin rates (RL: 11.8% vs. WL: 17.3%, p = 0.25) or re-excision rates (RL: 14.5% vs. WL: 21.8%, p = 0.221). In total, 290 RL cases are needed to break even. The cost of WLE using RL was greater than WL by AUD$567. There was a greater clinical benefit of 1.15 quality-adjusted life-years (QALYs) and an incremental cost-utility ratio of AUD$493 per QALY favouring RL. CONCLUSIONS: Routine use of RL was a more cost-effective intervention than WL. Close to 300 RL cases are likely needed to be performed to recover costs of the medical device. CLINICAL TRIAL REGISTRATION: ACTRN12624000068561.


Assuntos
Neoplasias da Mama , Análise Custo-Benefício , Humanos , Neoplasias da Mama/cirurgia , Neoplasias da Mama/economia , Neoplasias da Mama/patologia , Feminino , Estudos Prospectivos , Pessoa de Meia-Idade , Seguimentos , Mastectomia Segmentar/economia , Mastectomia Segmentar/métodos , Idoso , Margens de Excisão , Prognóstico , Anos de Vida Ajustados por Qualidade de Vida , Austrália , Cirurgia Assistida por Computador/economia , Cirurgia Assistida por Computador/métodos , Adulto
10.
J Cardiovasc Electrophysiol ; 35(1): 16-24, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37890041

RESUMO

INTRODUCTION: Mechanical force to achieve transseptal puncture (TSP) using a standard needle may lead to overshooting and injury, and can potentially be avoided using a radiofrequency (RF)-powered needle or wire. Applying electrocautery to needles and guidewires as an alternative to purpose-built RF systems has been associated with safety risks, such as tissue coring and thermal damage. The commercially available AcQCross needle-dilator system (Medtronic) features a sharp open-ended needle for mechanical puncture, as well as a built-in connector to enable energy delivery for RF puncture. This investigation compares the safety and efficacy of the AcQCross needle to the dedicated VersaCross RF wire system and generator (Baylis Medical/Boston Scientific). METHODS: In an ex vivo porcine model, VersaCross wire punctures were performed using 1 s, constant mode (approx. 10 W) with maximum two attempts. AcQCross punctures were performed by applying energy for 2 s using a standard electrosurgical generator at 10 W (max. five attempts), 20 W (max. two attempts), and 30 W (max. two attempts). Efficacy was assessed in terms of puncture success and a number of energy applications required for TSP. Safety was assessed quantitatively as force required for TSP, energy required to puncture, and incidence of tissue coring, as well as by qualitative assessment of puncture sites. Additional qualitative observation of tissue cores and debris were obtained from TSP performed in live swine. RESULTS: RF TSP was 100% successful using the VersaCross wire with 1.0 ± 0.0 attempts. When power was used with the AcQCross needle, it failed to puncture at low (10 and 20 W) power settings; TSP was achieved with 30 W of energy with 91% success using 1.53 ± 0.51 attempts (p < .05 vs. VC) with greater variability (F1,33 = 9223.5, p < .0001). Compared to RF puncture using the VersaCross system, mechanical puncture, alone, using the AcQcross needle required six times more force (8 mm additional forward device displacement) to perforate the septum. Qualitative assessment of puncture sites revealed larger defects and more tissue charring with the AcQCross needle at 30 W compared to punctures with VersaCross wire. Tissue coring with the open-ended AcQCross needle was observed in vivo and measured to occur in 57% of punctures using the ex vivo model; no coring was observed with the closed-tip VersaCross wire. CONCLUSIONS: The AcQCross needle frequently required higher energy of 30 W to achieve RF TSP and was associated with tissue coring and charring, which have been, previously, reported when electrifying a standard open-ended mechanical needle or guidewire. These findings may limit safety and effectiveness compared to the VersaCross system.


Assuntos
Ablação por Cateter , Suínos , Animais , Desenho de Equipamento , Eletrocoagulação , Agulhas , Punções , Modelos Animais , Resultado do Tratamento
11.
Rev Cardiovasc Med ; 25(3): 107, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-39076936

RESUMO

Background: Side branch (SB) occlusion after main vessel stenting is the main complication in treating coronary bifurcation lesions by provisional stenting. The Jailed Wire Technique (JWT), recommended by the European Bifurcation Club, is a standard technique to deal with this issue. The Jailed Balloon Technique (JBT) has been found to be more effective than the JWT in clinical practice by some interventionists, but it has not been widely accepted. In this meta-analysis, we compared the efficacy and safety of JBT and JWT. Methods: The literature comparing JBT and JWT was systematically reviewed. Stata/MP 17.0 was used to perform a meta-analysis. The primary endpoints were major adverse cardiac events (MACE), cardiac death, myocardial infarction (MI) and target lesion revascularization (TLR). The secondary endpoints were SB occlusion and SB dissection. Aggregated odds ratios and 95% confidence intervals were calculated. A sensitivity analysis was conducted if I 2 was > 50% or p < 0.01. Results: Thirteen studies involving 1789 patients were enrolled. JBT was found to have a significantly lower incidence of MACE, SB occlusion and dissection. The incidence of cardiac death, MI and TLR were also lower in the JBT group, though the differences were not significant. Conclusions: JBT prevents SB occlusion more effectively and does not increase immediate or long-term complications. JBT, or its modified versions, can be used to treat SBs with a high risk of occlusion.

12.
Amino Acids ; 56(1): 9, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38315214

RESUMO

Nanostructures formed by the self-assembly of modified/unmodified amino acids have the potential to be useful in several biological/nonbiological applications. In that regard, the greater conformational space provided by γ-amino acids, owing to their additional backbone torsional degrees of freedom and enhanced proteolytic stability, compared to their α-counterparts, should be explored. Though, modified single amino acid-based nanomaterials such as nanobelts or hydrogels are developed by utilizing the monosubstituted γ-amino acids derived from the backbone homologation of phenylalanine (Phe). Examples of a single γ-amino acid-based porous nanostructure capable of accommodating solvent molecules are not really known. The crystal structures of a modified γ4(R)Phe residue, Boc-γ4(R)Phe-OH, at different temperatures, showed that hydrogen-bonded water molecules are forming a wire inside hydrophilic nanochannels. The dynamics of intermolecular interactions between the water wire and the inner wall of the channel with relation to the temperature change was investigated by analyzing the natural bonding orbital (NBO) calculation results performed with the single crystal structures obtained at different temperature points. The NBO results showed that from 325 K onward, the strength of water-water interactions in the water wire are getting weaker, whereas, for the water-inner wall interactions, it getting stronger, suggesting a favorable change in the orientation of water molecules with temperatures, for the latter.


Assuntos
Aminoácidos , Água , Aminoácidos/química , Fenilalanina/química , Aminas/química , Conformação Molecular , Ligação de Hidrogênio
13.
Exp Brain Res ; 242(2): 403-416, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38135819

RESUMO

Foot orthoses (FO) are a commonly prescribed intervention to alter foot function during walking although their effects have been primarily studied in the extrinsic muscles of the foot. Furthermore, enhancing sensory feedback under the foot sole has been recently shown to alter extrinsic muscle activity during gait; however, the effects of FOs with enhanced sensory feedback on plantar intrinsic foot muscles (PIFMs) remain unknown. Thus, the purpose of this study was to investigate the effect of FOs with and without sensory facilitation on PIFM activity during locomotion. Forty healthy adults completed a series of gait trials in non-textured and textured FOs when walking over hard and soft flooring. Outcome measures included bilateral joint kinematics and electromyography (EMG) of four PIFMs. Results of this study highlight the distinct onset and cessations of each PIFM throughout the stance phase of gait. PIFMs remained active during mid-stance when wearing FOs and textured FOs facilitated muscle activity across the stance phase of gait. Increasing cutaneous input from foot sole skin, via the addition of texture under the foot sole, appears to alter motor-neuron pool excitation of PIFMs. Future academics are encouraged to increase our understanding on which pathologies, diseases, and/or medical conditions would best benefit from textured FOs.


Assuntos
, Músculo Esquelético , Adulto , Humanos , Pé/fisiologia , Músculo Esquelético/fisiologia , Locomoção , Caminhada/fisiologia , Marcha/fisiologia
14.
Environ Res ; 251(Pt 1): 118566, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38447606

RESUMO

Both g-C3N4 and Bi2O2CO3 are good photocatalysts for the removal of antibiotic pollutants, but their morphological modulation and catalytic performance need to be further improved. In this study, the calcination-hydrothermal method is used to prepare a O-g-C3N4@Bi2O2CO3 (CN@BCO) composite photocatalyst from dicyandiamide and bismuth nitrate. The prepared catalyst is characterized through various methods, including X-ray diffraction (XRD) and transmission electron microscopy (TEM). Further, the effects of different parameters, such as catalyst concentration and initial pH of the reaction solution, on its photocatalytic activity are investigated. The results show that the CN@BCO sample achieves an optimal degradation rate of 98.1% for tetracycline hydrochloride (TCH) with a concentration of 20 mg/L and a removal rate of 69.4% for total organic carbon (TOC) at 40 min. The quenching experiments show that ·O2-, h+, and ·OH participate in the photocatalytic process, with ·O2- being the most dominant active species. The toxicity of the predicted TCH degradation intermediates is analyzed using Toxicity Estimation Software Tool (TEST). Overall, the CN@BCO composite exhibits excellent photocatalytic performance, making it a promising candidate for environmental purification and wastewater treatment.


Assuntos
Bismuto , Tetraciclina , Águas Residuárias , Poluentes Químicos da Água , Tetraciclina/química , Poluentes Químicos da Água/química , Poluentes Químicos da Água/análise , Águas Residuárias/química , Bismuto/química , Catálise , Antibacterianos/química , Nanofios/química , Compostos de Nitrogênio/química , Nitrilas/química , Porosidade , Grafite
15.
Scand Cardiovasc J ; 58(1): 2347295, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38706409

RESUMO

Objectives. This study investigated the influence of higher pressure protection with a small diameter balloon of side branch (SB) on bifurcation lesions. Background. Of the different coronary stent implantation techniques, the modified jailed balloon technique has become a viable option for bifurcation lesions. However, there was no detailed study on the relationship between the balloon inflation pressure of the main vessel (MV) and SB. Methods. In this study, we collected information of patients who underwent percutaneous coronary intervention (PCI) for bifurcated lesions between March 2019 and December 2022. They were divided into two groups according to the operation way: active jailed balloon technique (A-JBT) group and jailed wire technique (JWT) group. Results. A total of 216 patients were enrolled. The A-JBT group had a larger SB stenosis diameter (1.53 ± 0.69 vs. 0.95 ± 0.52, p < .001), the lower degree of stenosis (44.34 ± 18.30 vs. 63.69 ± 17.34, p < .001) compared to the JWT group. However, the JWT group had a higher incidence of SB occlusion (18.0% vs. 1.9%, p < .001) compared to the A-JBT group. Nevertheless, the success rate for both groups was 100%. Conclusions. This novel high inflation pressure and small diameter balloon approach we propose has significant advantages. There is a lower rate of SB occlusion and SB dissection, which is more cost-effective and provides better clinical outcomes for the patient. This method should be considered in the future for treating bifurcation lesions.


Assuntos
Angioplastia Coronária com Balão , Cateteres Cardíacos , Doença da Artéria Coronariana , Humanos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico por imagem , Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/efeitos adversos , Estudos Retrospectivos , Stents , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Estenose Coronária/cirurgia , Fatores de Risco , Pressão , Fatores de Tempo , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação
16.
World J Surg Oncol ; 22(1): 51, 2024 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-38336734

RESUMO

BACKGROUND: Presurgical computed tomography (CT)-guided localization is frequently employed to reduce the thoracotomy conversion rate, while increasing the rate of successful sublobar resection of ground glass nodules (GGNs) via video-assisted thoracoscopic surgery (VATS). In this study, we compared the clinical efficacies of presurgical CT-guided hook-wire and indocyanine green (IG)-based localization of GGNs. METHODS: Between January 2018 and December 2021, we recruited 86 patients who underwent CT-guided hook-wire or IG-based GGN localization before VATS resection in our hospital, and compared the clinical efficiency and safety of both techniques. RESULTS: A total of 38 patients with 39 GGNs were included in the hook-wire group, whereas 48 patients with 50 GGNs were included in the IG group. There were no significant disparities in the baseline data between the two groups of patients. According to our investigation, the technical success rates of CT-based hook-wire- and IG-based localization procedures were 97.4% and 100%, respectively (P = 1.000). Moreover, the significantly longer localization duration (15.3 ± 6.3 min vs. 11.2 ± 5.3 min, P = 0.002) and higher visual analog scale (4.5 ± 0.6 vs. 3.0 ± 0.5, P = 0.001) were observed in the hook-wire patients, than in the IG patients. Occurrence of pneumothorax was significantly higher in hook-wire patients (27.3% vs. 6.3%, P = 0.048). Lung hemorrhage seemed higher in hook-wire patients (28.9% vs. 12.5%, P = 0.057) but did not reach statistical significance. Lastly, the technical success rates of VATS sublobar resection were 97.4% and 100% in hook-wire and IG patients, respectively (P = 1.000). CONCLUSIONS: Both hook-wire- and IG-based localization methods can effectively identified GGNs before VATS resection. Furthermore, IG-based localization resulted in fewer complications, lower pain scores, and a shorter duration of localization.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Nódulo Pulmonar Solitário , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Verde de Indocianina , Nódulo Pulmonar Solitário/diagnóstico por imagem , Nódulo Pulmonar Solitário/cirurgia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Cirurgia Torácica Vídeoassistida/métodos , Pulmão , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/cirurgia
17.
World J Surg Oncol ; 22(1): 178, 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38971793

RESUMO

BACKGROUND: Any advantage of performing targeted axillary dissection (TAD) compared to sentinel lymph node (SLN) biopsy (SLNB) is under debate in clinically node-positive (cN+) patients diagnosed with breast cancer. Our objective was to assess the feasibility of the removal of the clipped node (RCN) with TAD or without imaging-guided localisation by SLNB to reduce the residual axillary disease in completion axillary lymph node dissection (cALND) in cN+ breast cancer. METHODS: A combined analysis of two prospective cohorts, including 253 patients who underwent SLNB with/without TAD and with/without ALND following NAC, was performed. Finally, 222 patients (cT1-3N1/ycN0M0) with a clipped lymph node that was radiologically visible were analyzed. RESULTS: Overall, the clipped node was successfully identified in 246 patients (97.2%) by imaging. Of 222 patients, the clipped lymph nodes were non-SLNs in 44 patients (19.8%). Of patients in cohort B (n=129) with TAD, the clipped node was successfully removed by preoperative image-guided localisation, or the clipped lymph node was removed as the SLN as detected on preoperative SPECT-CT. Among patients with ypSLN(+) (n=109), no significant difference was found in non-SLN positivity at cALND between patients with TAD and RCN (41.7% vs. 46.9%, p=0.581). In the subgroup with TAD with axillary lymph node dissection (ALND; n=60), however, patients with a lymph node (LN) ratio (LNR) less than 50% and one metastatic LN in the TAD specimen were found to have significantly decreased non-SLN positivity compared to others (27.6% vs. 54.8%, p=0.032, and 22.2% vs. 50%, p=0.046). CONCLUSIONS: TAD by imaging-guided localisation is feasible with excellent identification rates of the clipped node. This approach has also been found to reduce the additional non-SLN positivity rate to encourage omitting ALND in patients with a low metastatic burden undergoing TAD.


Assuntos
Axila , Neoplasias da Mama , Excisão de Linfonodo , Terapia Neoadjuvante , Neoplasia Residual , Biópsia de Linfonodo Sentinela , Humanos , Feminino , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/diagnóstico por imagem , Excisão de Linfonodo/métodos , Pessoa de Meia-Idade , Terapia Neoadjuvante/métodos , Estudos Prospectivos , Adulto , Biópsia de Linfonodo Sentinela/métodos , Idoso , Neoplasia Residual/cirurgia , Neoplasia Residual/patologia , Linfonodos/patologia , Linfonodos/cirurgia , Linfonodos/diagnóstico por imagem , Seguimentos , Prognóstico , Metástase Linfática , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Estudos de Viabilidade
18.
BMC Musculoskelet Disord ; 25(1): 56, 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38216954

RESUMO

BACKGROUND: To analyze the clinical efficacy of K-wire placement guided technology in paediatric supracondylar humerus fractures. METHODS: A retrospective study was conducted in 105 patients who underwent closed reduction and percutaneous pinning surgeries in our hospital from June 2019 to August 2022. 54 patients treated with a assisted reduction fixation device to assist in closed reduction and percutaneous K-wire cross-fixation were allocated into the Non-guided group, and 51 patients with K-wire placement guided technology to guide K-wire placement were assigned into the Guided group. The operation duration, number of disposable K-wire placement, intraoperative fluoroscopy frequency, Baumann angle, carrying angle, fracture healing time and Flynn score of elbow joint function at the final follow-up were compared between two groups. The postoperative complications of two groups were recorded. RESULTS: There were significant differences between two groups in terms of operation duration, intraoperative fluoroscopy frequency, and disposable K-wire placement rate (p < 0. 05), while no significant differences of Baumann angle, carrying angle and the fracture healing time between two groups were observed (p > 0. 05). In the control group, ulnar nerve injury in 2 case, pin site infection in 4 cases, mild cubitus varus in 2 cases and loss of reduction in 4 cases were detected. In the study group, ulnar nerve injury in 1 case, pin site infection in 2 cases and loss of reduction in 1 case was observed. There was no significant difference in Flynn scores between two groups. CONCLUSION: K-wire placement guided technology is simple and convenient. The application of K-wire placement guided technology could relatively improved disposable K-wire placement rate, shorten the intraoperative fluoroscopy frequencies and reduce complication rates.


Assuntos
Fios Ortopédicos , Fraturas do Úmero , Criança , Humanos , Estudos Retrospectivos , Fraturas do Úmero/diagnóstico por imagem , Fraturas do Úmero/cirurgia , Fluoroscopia , Fixação Interna de Fraturas/efeitos adversos , Resultado do Tratamento , Tecnologia , Úmero
19.
BMC Musculoskelet Disord ; 25(1): 350, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702748

RESUMO

BACKGROUND: Metacarpal shaft fracture is a common type of hand fracture. Numerous studies have explored fixing transverse fractures in the midshaft of the metacarpal bone. However, this section of the metacarpal bone is often susceptible to high-energy injury, resulting in comminuted fracture or bone loss. In such cases, wedge-shaped bone defects can develop in the metacarpal shaft, increasing the difficulty of performing fracture fixation. Notably, the research on this type of fracture fixation is limited. This study compared the abilities of four fixation methods to fix metacarpal shaft fractures with wedge-shaped bone defects. METHODS: In total, 28 artificial metacarpal bones were used. To create wedge-shaped bone defects, an electric saw was used to create metacarpal shaft fractures at the midshaft of each bone. The artificial metacarpal bones were then divided into four groups for fixation. The bones in the first group were fixed with a dorsal locked plate (DP group), those in the second group were fixed with a volar locked plate (VP group), and those in the third group were fixed by combining dorsal and volar locked plates (DP + VP group), and those in the fourth group were fixed with two K-wires (2 K group). Cantilever bending tests were conducted using a material testing machine to measure yielding force and stiffness. The four groups' fixation capabilities were then assessed through analysis of variance and Tukey's test. RESULTS: The DP + VP group (164.1±44.0 N) achieved a significantly higher yielding force relative to the 2 K group (50.7 ± 8.9 N); the DP group (13.6 ± 3.0 N) and VP group (12.3 ± 1.0 N) did not differ significantly in terms of yielding force, with both achieving lower yielding forces relative to the DP + VP group and 2 K group. The DP + VP group (19.8±6.3 N/mm) achieved the highest level of stiffness, and the other three groups did not differ significantly in terms of stiffness (2 K group, 5.4 ± 1.1 N/mm; DP group, 4.0 ± 0.9 N/mm; VP group, 3.9 ± 1.9 N/mm). CONCLUSIONS: The fixation method involving the combined use of dorsal and volar locked plates (DP + VP group) resulted in optimal outcomes with respect to fixing metacarpal shaft fractures with volar wedge bone defects.


Assuntos
Placas Ósseas , Fios Ortopédicos , Fixação Interna de Fraturas , Fraturas Ósseas , Ossos Metacarpais , Ossos Metacarpais/lesões , Ossos Metacarpais/cirurgia , Humanos , Fenômenos Biomecânicos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia
20.
Lasers Med Sci ; 39(1): 122, 2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38703271

RESUMO

Pulsed dye lasers are used effectively in the treatment of psoriasis with long remission time and limited side effects. It is, however, not completely understood which biological processes underlie its favorable outcome. Pulsed dye laser treatment at 585-595 nm targets hemoglobin in the blood, inducing local hyperthermia in surrounding blood vessels and adjacent tissues. While the impact of destructive temperatures on blood vessels has been well studied, the effects of lower temperatures on the function of several cell types within the blood vessel wall and its periphery are not known. The aim of our study is to assess the functionality of isolated blood vessels after exposure to moderate hyperthermia (45 to 60°C) by evaluating the function of endothelial cells, smooth muscle cells, and vascular nerves. We measured blood vessel functionality of rat mesenteric arteries (n=19) by measuring vascular contraction and relaxation before and after heating vessels in a wire myograph. To this end, we elicited vascular contraction by addition of either high potassium solution or the thromboxane analogue U46619 to stimulate smooth muscle cells, and electrical field stimulation (EFS) to stimulate nerves. For measurement of endothelium-dependent relaxation, we used methacholine. Each vessel was exposed to one temperature in the range of 45-60°C for 30 seconds and a relative change in functional response after hyperthermia was determined by comparison with the response per stimulus before heating. Non-linear regression was used to fit our dataset to obtain the temperature needed to reduce blood vessel function by 50% (Half maximal effective temperature, ET50). Our findings demonstrate a substantial decrease in relative functional response for all three cell types following exposure to 55°C-60°C. There was no significant difference between the ET50 values of the different cell types, which was between 55.9°C and 56.9°C (P>0.05). Our data show that blood vessel functionality decreases significantly when exposed to temperatures between 55°C-60°C for 30 seconds. The results show functionality of endothelial cells, smooth muscle cells, and vascular nerves is similarly impaired. These results help to understand the biological effects of hyperthermia and may aid in tailoring laser and light strategies for selective photothermolysis that contribute to disease modification of psoriasis after pulsed dye laser treatment.


Assuntos
Lasers de Corante , Animais , Ratos , Masculino , Lasers de Corante/uso terapêutico , Miócitos de Músculo Liso/fisiologia , Miócitos de Músculo Liso/efeitos da radiação , Vasodilatação/efeitos da radiação , Vasodilatação/fisiologia , Temperatura , Músculo Liso Vascular/efeitos da radiação , Músculo Liso Vascular/fisiologia , Células Endoteliais/efeitos da radiação , Células Endoteliais/fisiologia , Vasoconstrição/efeitos da radiação , Vasoconstrição/fisiologia , Endotélio Vascular/efeitos da radiação , Ratos Wistar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA