Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 278
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Cell ; 184(25): 6157-6173.e24, 2021 12 09.
Artigo em Inglês | MEDLINE | ID: mdl-34856126

RESUMO

Chromosome loops shift dynamically during development, homeostasis, and disease. CCCTC-binding factor (CTCF) is known to anchor loops and construct 3D genomes, but how anchor sites are selected is not yet understood. Here, we unveil Jpx RNA as a determinant of anchor selectivity. Jpx RNA targets thousands of genomic sites, preferentially binding promoters of active genes. Depleting Jpx RNA causes ectopic CTCF binding, massive shifts in chromosome looping, and downregulation of >700 Jpx target genes. Without Jpx, thousands of lost loops are replaced by de novo loops anchored by ectopic CTCF sites. Although Jpx controls CTCF binding on a genome-wide basis, it acts selectively at the subset of developmentally sensitive CTCF sites. Specifically, Jpx targets low-affinity CTCF motifs and displaces CTCF protein through competitive inhibition. We conclude that Jpx acts as a CTCF release factor and shapes the 3D genome by regulating anchor site usage.


Assuntos
Fator de Ligação a CCCTC/metabolismo , Cromossomos/metabolismo , RNA Longo não Codificante/metabolismo , Animais , Sítios de Ligação , Linhagem Celular , Células-Tronco Embrionárias , Camundongos , Ligação Proteica
2.
Nano Lett ; 24(36): 11210-11216, 2024 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-39054892

RESUMO

Lipids and nucleic acids are two of the most abundant components of our cells, and both molecules are widely used as engineering materials for nanoparticles. Here, we present a systematic study of how hydrophobic modifications can be employed to modulate the DNA/lipid interface. Using a series of DNA anchors with increasing hydrophobicity, we quantified the capacity to immobilize double-stranded (ds) DNA to lipid membranes in the liquid phase. Contrary to electrostatic effects, hydrophobic anchors are shown to be phase-independent if sufficiently hydrophobic. For weak anchors, the overall hydrophobicity can be enhanced following the concept of multivalency. Finally, we demonstrate that structural flexibility and anchor orientation overrule the effect of multivalency, emphasizing the need for careful scaffold design if strong interfaces are desired. Together, our findings guide the design of tailored DNA/membrane interfaces, laying the groundwork for advancements in biomaterials, drug delivery vehicles, and synthetic membrane mimics for biomedical research and nanomedicine.


Assuntos
DNA , Interações Hidrofóbicas e Hidrofílicas , DNA/química , Lipídeos/química , Bicamadas Lipídicas/química , Eletricidade Estática , Propriedades de Superfície
3.
Sensors (Basel) ; 24(5)2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38474928

RESUMO

Electromyography (EMG) proves invaluable myoelectric manifestation in identifying neuromuscular alterations resulting from ischemic strokes, serving as a potential marker for diagnostics of gait impairments caused by ischemia. This study aims to develop an interpretable machine learning (ML) framework capable of distinguishing between the myoelectric patterns of stroke patients and those of healthy individuals through Explainable Artificial Intelligence (XAI) techniques. The research included 48 stroke patients (average age 70.6 years, 65% male) undergoing treatment at a rehabilitation center, alongside 75 healthy adults (average age 76.3 years, 32% male) as the control group. EMG signals were recorded from wearable devices positioned on the bicep femoris and lateral gastrocnemius muscles of both lower limbs during indoor ground walking in a gait laboratory. Boosting ML techniques were deployed to identify stroke-related gait impairments using EMG gait features. Furthermore, we employed XAI techniques, such as Shapley Additive Explanations (SHAP), Local Interpretable Model-Agnostic Explanations (LIME), and Anchors to interpret the role of EMG variables in the stroke-prediction models. Among the ML models assessed, the GBoost model demonstrated the highest classification performance (AUROC: 0.94) during cross-validation with the training dataset, and it also overperformed (AUROC: 0.92, accuracy: 85.26%) when evaluated using the testing EMG dataset. Through SHAP and LIME analyses, the study identified that EMG spectral features contributing to distinguishing the stroke group from the control group were associated with the right bicep femoris and lateral gastrocnemius muscles. This interpretable EMG-based stroke prediction model holds promise as an objective tool for predicting post-stroke gait impairments. Its potential application could greatly assist in managing post-stroke rehabilitation by providing reliable EMG biomarkers and address potential gait impairment in individuals recovering from ischemic stroke.


Assuntos
Compostos de Cálcio , AVC Isquêmico , Óxidos , Acidente Vascular Cerebral , Adulto , Humanos , Masculino , Idoso , Feminino , Inteligência Artificial , Eletromiografia
4.
Angew Chem Int Ed Engl ; 63(24): e202403050, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38579168

RESUMO

Unstable Zn interface with serious detrimental parasitic side-reactions and uncontrollable Zn dendrites severely plagues the practical application of aqueous zinc-ion batteries. The interface stability was closely related to the electrolyte configuration and Zn2+ depositional behavior. In this work, a unique Zn-ion anchoring strategy is originally proposed to manipulate the coordination structure of solvated Zn-ions and guide the Zn-ion depositional behavior. Specifically, the amphoteric charged ion additives (denoted as DM), which act as zinc-ion anchors, can tightly absorb on the Zn surface to guide the uniform zinc-ion distribution by using its positively charged -NR4 + groups. While the negatively charged -SO3 - groups of DM on the other hand, reduces the active water molecules within solvation sheaths of Zn-ions. Benefiting from the special synergistic effect, Zn metal exhibits highly ordered and compact (002) Zn deposition and negligible side-reactions. As a result, the advanced Zn||Zn symmetric cell delivers extraordinarily 7000 hours long lifespan (0.25 mA cm-2, 0.25 mAh cm-2). Additionally, based on this strategy, the NH4V4O10||Zn pouch-cell with low negative/positive capacity ratio (N/P ratio=2.98) maintains 80.4 % capacity retention for 180 cycles. A more practical 4 cm*4 cm sized pouch-cell could be steadily cycled in a high output capacity of 37.0 mAh over 50 cycles.

5.
Brief Bioinform ; 22(6)2021 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-34263910

RESUMO

Epigenomics and transcriptomics data from high-throughput sequencing techniques such as RNA-seq and ChIP-seq have been successfully applied in predicting gene transcript expression. However, the locations of chromatin loops in the genome identified by techniques such as Chromatin Interaction Analysis with Paired End Tag sequencing (ChIA-PET) have never been used for prediction tasks. Here, we developed machine learning models to investigate if ChIA-PET could contribute to transcript and exon usage prediction. In doing so, we used a large set of transcription factors as well as ChIA-PET data. We developed different Gradient Boosting Trees models according to the different tasks with the integrated datasets from three cell lines, including GM12878, HeLaS3 and K562. We validated the models via 10-fold cross validation, chromosome-split validation and cross-cell validation. Our results show that both transcript and splicing-derived exon usage can be effectively predicted with at least 0.7512 and 0.7459 of accuracy, respectively, on all cell lines from all kinds of validations. Examining the predictive features, we found that RNA Polymerase II ChIA-PET was one of the most important features in both transcript and exon usage prediction, suggesting that chromatin loop anchors are predictive of both transcript and exon usage.


Assuntos
Montagem e Desmontagem da Cromatina/genética , Cromatina/genética , Biologia Computacional/métodos , Éxons , Transcrição Gênica , Metilação de DNA , Epigênese Genética , Epigenômica/métodos , Regulação da Expressão Gênica , Histonas/metabolismo , Modelos Biológicos , Reprodutibilidade dos Testes
6.
Plant Cell Environ ; 46(4): 1195-1206, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36138316

RESUMO

Leaf-form ferredoxin-NADP+ oxidoreductases (LFNRs) function in the last step of the photosynthetic electron transport chain, exist as soluble proteins in the chloroplast stroma and are weakly associated with thylakoids or tightly anchored to chloroplast membranes. Arabidopsis thaliana has two LFNRs, and the chloroplast proteins AtTROL and AtTIC62 participate in anchoring AtLFNRs to the thylakoid membrane. By contrast, the membrane anchoring mechanism of rice (Oryza sativa) LFNRs has not been elucidated. Here, we investigated the membrane-anchoring mechanism of LFNRs and its physiological roles in rice. We characterized the rice protein OsTROL1 based on its homology to AtTROL. We determined that OsTROL1 is also a thylakoid membrane anchor and its loss leads to a compensatory increase in OsTIC62. OsLFNR1 attachment through a membrane anchor depends on OsLFNR2, unlike the Arabidopsis counterparts. In addition, OsTIC62 was more highly expressed in the dark than under light conditions, consistent with the increased membrane binding of OsLFNR in the dark. Moreover, we observed reciprocal stabilization between OsLFNRs and their membrane anchors. In addition, unlike in Arabidopsis, the loss of LFNR membrane anchor affects photosynthesis in rice. Overall, our study sheds light on the mechanisms anchoring LFNRs to membranes in rice and highlights differences with Arabidopsis.


Assuntos
Proteínas de Arabidopsis , Arabidopsis , Oryza , Arabidopsis/metabolismo , Oryza/metabolismo , Proteínas de Arabidopsis/metabolismo , Ferredoxinas/metabolismo , NADP/metabolismo , Cloroplastos/metabolismo , Fotossíntese , Ferredoxina-NADP Redutase/metabolismo , Folhas de Planta/metabolismo
7.
Chemistry ; 29(72): e202302663, 2023 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-37782056

RESUMO

The development of efficient photocathodes is of critical importance for the constructions of promising tandem photo-electrochemical cells. Most known dye-sensitized photocathodes are prepared with the conventional carboxylic or phosphonic acid anchors and require the presence of other terminal linking groups to connect catalysts; they suffer from high synthetic difficulty and low adsorption stability in aqueous media. Here, a compact bilayer photocathode has been prepared by using a pyrene-based photosensitizer with multiple terminal pyridine moieties as both the anchoring and linking groups to connect a Co hydrogen-evolution catalyst to the NiO substrate. The catalyst and dye molecule are assembled in a layer-by-layer manner on NiO through the metal-pyridine coordination. This photocathode exhibits good dye adsorption stability in aqueous media. A stable cathodic photocurrent of 70 µA cm-2 was achieved, with H2 being generated at the photocathode under the visible-light irradiation. The Faraday efficiency of H2 evolution was estimated to be 9.1 %. Transient absorption spectral studies suggest that the interfacial hole transfer occurs within a few picoseconds. The integration of the organic photosensitizer with pyridine anchoring and linking groups is expected to provide a simple method for the fabrication of stable and efficient photocathodes.

8.
J Shoulder Elbow Surg ; 32(12): 2541-2549, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37352999

RESUMO

BACKGROUND: Deciding how many anchors to use in a Bankart repair is challenging because of the desire to enhance stability while avoiding a postage-stamp fracture of the glenoid rim. METHODS: This controlled laboratory study investigated load to fracture of the anterior glenoid rim after drilling holes of varying number and diameter and inserting anchors of 2 different types and sizes, with and without perforation of the medial cortex of the glenoid, creating postage-stamp fractures using a metallic humeral head that was compressed against the anterior glenoid rim. A destructive model with a servohydraulic load frame was used to test 46 synthetic scapulae with compressive strength and elastic modulus similar to that of a human glenoid. Load to fracture of the intact glenoid was compared with groups with a varying number of anchor holes of different diameters, with anchors of different sizes and types, and with anchors perforating or not perforating the glenoid medial cortex. The percentage of force to fracture an intact specimen was used to identify relative risk of fracture: low risk >75%, moderate risk 75%-50%, and high risk <50% of intact load. RESULTS: The load to fracture of intact glenoids was 1276 ± 42 N. Loads decreased linearly as the number of holes drilled on the glenoid rim increased. Compared with the 1.6-mm group, the 3.0-mm group had significantly lower glenoid rim strength in specimens with 4, 5, and 7 holes (P = .013, .032, and .045, respectively). All-suture anchors in 1.6-mm holes did not alter the glenoid rim strength, and up to 5 anchors were associated with low risk of fracture. Load to fracture was significantly higher with 3.0-mm rigid core bioabsorbable anchors with 4 anchors (1081 ± 6 N) compared with the 4-hole condition (838 ± 107 N; P = .033). Perforating the glenoid medial cortex with five 1.6-mm anchors significantly weakened the glenoid rim to 58% of intact (P = .012). Perforating the medial cortex weakened the glenoid rim to 52% and 42% (P < .001 for both) of intact in the 3.0-mm 4-anchor and 5-anchor constructions, constituting moderate and high risk of fracture, respectively. CONCLUSION: Up to five 1.6-mm all-suture anchors and four 3.0-mm bioabsorbable rigid-core anchors were associated with low risk of fracture of the glenoid rim. Smaller diameter all-suture anchors best preserved structural integrity of the glenoid rim, whereas tunnel enlargement and perforation of the glenoid medial cortex were associated with moderate or high risk of a postage-stamp fracture.


Assuntos
Fraturas Ósseas , Instabilidade Articular , Articulação do Ombro , Humanos , Articulação do Ombro/cirurgia , Instabilidade Articular/cirurgia , Escápula/cirurgia , Fraturas Ósseas/cirurgia , Artroscopia/efeitos adversos
9.
J Shoulder Elbow Surg ; 32(2): 333-339, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36049702

RESUMO

BACKGROUND: The use of anchors in the proximal humerus during arthroscopic surgery can cause localized bone loss due to osteolysis and cyst formation. The purpose of this study was to use computed tomography (CT) to evaluate the incidence of implant-related bone loss and cyst formation after implantation of polyetheretherketone (PEEK) coil-type open-architecture anchors during remplissage for the management of Hill-Sachs defects (HSDs) in patients with shoulder instability. METHODS: This was a single-cohort, observational study with a minimum of 12 months of follow-up. Subjects undergoing arthroscopic instability surgery with HSD requiring remplissage were included. The volume of the bone defects and the degree of bony ingrowth into the anchor were measured on CT images. RESULTS: Thirty-one participants (28 males, 3 females; mean age 29.4 years, standard deviation [SD] 10.6) in whom 50 anchors (4.5-mm Healicoil PEEK double-loaded anchors) were used were evaluated with a CT performed at a mean of 14.1 (SD 3.74) months after surgery. Full bony ingrowth inside the anchor was found in 15 anchors (30%, range 17.8%-44.5%); clear ossification with a thin lucent rim was found in 10 anchors (20%, range 10.0%-33.7%); discontinuous ossification was found in 8 anchors (16%, range 7.2%-29.1%); and no ossification was observed inside 17 anchors (34%, range 21.2%-48.7%). Regarding bone defect size, no bone defect was identified in 15 anchors (30%, 95% CI 17.9%-44.6%), a partial bone defect was found in 17 anchors (34%, 95% CI 21.2%-48.7%), hole enlargement was found in 17 anchors (34%, 95% CI 21.2%-48.7%), and 1 anchor caused a cyst larger than twice the size of the hole made for anchor insertion (2%, 95% CI 0.1%-8.6%). At the 1-year evaluation, none of the participants presented recurrence or residual apprehension. CONCLUSION: The use of PEEK coil-type open-architecture anchors for remplissage during instability surgery caused large cystic lesions in less than 10% of anchors. There was full bony ingrowth in one-third of anchors, and partial cancellous bone ingrowth occurred in another third of anchors.


Assuntos
Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Masculino , Feminino , Humanos , Adulto , Luxação do Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Instabilidade Articular/cirurgia , Recidiva Local de Neoplasia , Artroscopia/métodos , Polietilenoglicóis , Cetonas , Recidiva
10.
Sensors (Basel) ; 23(3)2023 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-36772178

RESUMO

The aim of this study was to develop a physical activity advisory system supporting the correct implementation of sport exercises using inertial sensors and machine learning algorithms. Specifically, three mobile sensors (tags), six stationary anchors and a system-controlling server (gateway) were employed for 15 scenarios of the series of subsequent activities, namely squats, pull-ups and dips. The proposed solution consists of two modules: an activity recognition module (ARM) and a repetition-counting module (RCM). The former is responsible for extracting the series of subsequent activities (so-called scenario), and the latter determines the number of repetitions of a given activity in a single series. Data used in this study contained 488 three defined sport activity occurrences. Data processing was conducted to enhance performance, including an overlapping and non-overlapping window, raw and normalized data, a convolutional neural network (CNN) with an additional post-processing block (PPB) and repetition counting. The developed system achieved satisfactory accuracy: CNN + PPB: non-overlapping window and raw data, 0.88; non-overlapping window and normalized data, 0.78; overlapping window and raw data, 0.92; overlapping window and normalized data, 0.87. For repetition counting, the achieved accuracies were 0.93 and 0.97 within an error of ±1 and ±2 repetitions, respectively. The archived results indicate that the proposed system could be a helpful tool to support the correct implementation of sport exercises and could be successfully implemented in further work in the form of web application detecting the user's sport activity.

11.
J Orthop Sci ; 2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37236874

RESUMO

BACKGROUND: The Fosbury flop tear (FFT) has recently been described as a rotator cuff tear that has flipped upon itself and adhered medially. FFT is known to have a high retear rate after arthroscopic rotator cuff repair. The cause of the high postoperative retear rate after arthroscopic rotator cuff repair is believed to be due to the inability to achieve anatomical reduction because of difficulties in reducing the torn tendon stump. Arthroscopic rotator cuff repairs using the triple-row technique may allow better anatomical reduction of the cuff tear when compared with the suture-bridge technique. We compared the clinical outcomes and cuff integrity of the triple-row and suture-bridge techniques in arthroscopic rotator cuff repair for FFT. METHODS: Patients with small-to-medium sized cuff tears of the supraspinatus tendon alone who were diagnosed with FFT, underwent arthroscopic rotator cuff repair, and had 2 or more years of follow-up were included. A total of 34 shoulders underwent the triple-row technique and 22 shoulders underwent the suture-bridge technique. The following were compared between the two techniques: patient background, operation time, number of anchors used during the operation, Japanese Orthopedic Association (JOA) score, active range of motion, and retear rate. RESULTS: No significant difference in patient background was found between the two techniques. Although active range of motion was significantly improved compared with preoperative scores, no significant difference was observed between techniques. The triple-row technique demonstrated a significantly higher 24-month postoperative JOA score, significantly shorter surgery time, significantly lower retear rate, and significantly larger number of anchors used during the operation. CONCLUSIONS: The triple-row technique was an effective method compared with the suture-bridge technique in cases with FFT.

12.
J Foot Ankle Surg ; 62(4): 723-726, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37037736

RESUMO

Primary repair of the deltoid ligament is a common surgical option for unstable ankle fracture. However, controversy exists regarding whether such repair is necessary or provides any benefit to patient outcomes. A retrospective study was performed following acute deltoid repairs using all-suture bone anchors. Patients at 2 surgical centers were included when they were over 18 years old at surgery, had a medial clear space (MCS) greater than 4 mm preoperatively, and had at least 6 months of follow-up. Subjective outcomes were measured with PROMIS, FAAM, and numeric rating scale. Preoperative and follow-up scores were compared with t tests (p < .05). For the 47 patients identified, age at time of surgery was 30.6 ± 14.9 years (range 15.4-65.0 years). Follow-up data were captured for 36 (73%) of the patients at 75 ± 37 weeks (range 18-169 weeks) after surgery. Mean time to weightbearing was 4 ± 1 weeks (range 1-7 weeks). Patients returned to sport 14 ± 5 weeks after surgery (range 8-41 weeks). Various complications consisted of wound infection, superficial dehiscence, and complex regional pain syndrome (CRPS). The PROMIS, FAAM, and NRS patient outcome scores improved significantly from preoperative to postoperative follow-up. Significant reduction in the radiographic MCS postoperatively occurred in all patients. These findings suggest primary deltoid repair when associated with ankle fracture to be a safe procedure and has the potential of allowing early weightbearing and return to sports.


Assuntos
Fraturas do Tornozelo , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Âncoras de Sutura , Estudos Retrospectivos , Ligamentos Articulares/cirurgia , Fixação Interna de Fraturas/métodos , Articulação do Tornozelo/cirurgia , Resultado do Tratamento
13.
BMC Med Imaging ; 22(1): 130, 2022 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-35870877

RESUMO

BACKGROUND: Cervical cancer cell detection is an essential means of cervical cancer screening. However, for thin-prep cytology test (TCT)-based images, the detection accuracies of traditional computer-aided detection algorithms are typically low due to the overlapping of cells with blurred cytoplasmic boundaries. Some typical deep learning-based detection methods, e.g., ResNets and Inception-V3, are not always efficient for cervical images due to the differences between cervical cancer cell images and natural images. As a result, these traditional networks are difficult to directly apply to the clinical practice of cervical cancer screening. METHOD: We propose a cervical cancer cell detection network (3cDe-Net) based on an improved backbone network and multiscale feature fusion; the proposed network consists of the backbone network and a detection head. In the backbone network, a dilated convolution and a group convolution are introduced to improve the resolution and expression ability of the model. In the detection head, multiscale features are obtained based on a feature pyramid fusion network to ensure the accurate capture of small cells; then, based on the Faster region-based convolutional neural network (R-CNN), adaptive cervical cancer cell anchors are generated via unsupervised clustering. Furthermore, a new balanced L1-based loss function is defined, which reduces the unbalanced sample contribution loss. RESULT: Baselines including ResNet-50, ResNet-101, Inception-v3, ResNet-152 and the feature concatenation network are used on two different datasets (the Data-T and Herlev datasets), and the final quantitative results show the effectiveness of the proposed dilated convolution ResNet (DC-ResNet) backbone network. Furthermore, experiments conducted on both datasets show that the proposed 3cDe-Net, based on the optimal anchors, the defined new loss function, and DC-ResNet, outperforms existing methods and achieves a mean average precision (mAP) of 50.4%. By performing a horizontal comparison of the cells on an image, the category and location information of cancer cells can be obtained concurrently. CONCLUSION: The proposed 3cDe-Net can detect cancer cells and their locations on multicell pictures. The model directly processes and analyses samples at the picture level rather than at the cellular level, which is more efficient. In clinical settings, the mechanical workloads of doctors can be reduced, and their focus can be placed on higher-level review work.


Assuntos
Neoplasias do Colo do Útero , Feminino , Humanos , Algoritmos , Detecção Precoce de Câncer/métodos , Processamento de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Neoplasias do Colo do Útero/diagnóstico por imagem
14.
Orthod Craniofac Res ; 25(2): 243-250, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34468065

RESUMO

OBJECTIVE: To compare the treatment effects of five bone-anchored maxillary protraction protocols (BAC3E, BAMP, BARME-FM, BARME-ME, SAFM) for skeletal Class III malocclusion. METHODS: We conducted a systematic literature search through CENTRAL, EBSCO, PubMed and Web of Science and included the randomized controlled trials and clinical controlled trials, which met the criteria. A Bayesian network meta-analysis (NMA) for SNA, SNB, ANB, SN-MP and Wits appraisal was performed in R software using a random consistency model. The additional analyses included node-splitting analysis, statistical heterogeneity analysis, sensitivity analysis and ranking probability by SUCRA. RESULTS: A total of 598 articles were initially obtained; 13 articles involving 482 individuals were eventually included. Among the five bone-anchored maxillary protraction protocols, the largest increment in SNA and Wits appraisal was observed in the BAMP group and BAC3E group, respectively; the SAFM, BAC3E and BAMP groups showed similar capability in terms of changes of ANB; least clockwise rotation of the mandible was found in the BARME-ME group, followed by the BAMP group; dental compensation appears to be most pronounced in the BAC3E group; and intermaxillary traction seems to reduce the lingual inclination of lower incisors and even cause labial inclination. CONCLUSIONS: The SAFM, BAMP and BAC3E groups seem to be advantageous in the improvement of the maxillo-mandibular relationship, followed by the BARME-FM and BARME-ME groups. The findings of this study should be interpreted with caution as only short-term effects were compared and the quality of evidence ranged from very low to moderate. More RCTs with high-quality and long-term investigation are needed.


Assuntos
Aparelhos de Tração Extrabucal , Má Oclusão Classe III de Angle , Teorema de Bayes , Cefalometria/métodos , Humanos , Má Oclusão Classe III de Angle/terapia , Maxila , Metanálise em Rede , Técnica de Expansão Palatina
15.
BMC Musculoskelet Disord ; 23(1): 634, 2022 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-35788222

RESUMO

BACKGROUND: Foveal tears of the traumatic triangular fibrocartilage complex (TFCC) are the most commonly neglected high-energy injuries of the wrist joint, and the patients with such tears often experience unrecovered ulnar-sided wrist pain and poor wrist function. This study investigated the functional outcomes of patients who underwent arthroscopic repair of foveal TFCC tears with suture anchors and adjuvant platelet-rich plasma (PRP) injections after the surgery. METHODS: From September 2014 to August 2018, 156 men and 45 women with diagnoses of foveal TFCC tears without wrist fractures underwent arthroscopic repair by using the outside-in method with 1.3-mm suture anchors and subsequent PRP injection. After surgery, splinting was applied for 6 weeks, and the patients underwent rehabilitation, re-examination, and follow-up at our clinic. The patients' wrist functional scores and grip strength data were retrospectively collected. RESULTS: The mean follow-up period was 32.6 months, and the mean age was 26.7 years. The mean modified Mayo wrist score improved from 48.5 ± 2.6 to 82.4 ± 2.5, whereas the mean Disabilities of the Arm, Shoulder and Hand (DASH) score decreased from 39.2 ± 6.7 to 10.6 ± 7.5. Overall, the wrist functions of 186 (92.5%) of the patients were satisfactory according to their modified Mayo wrist scores, and the patients with satisfactory scores returned to sports or work activities. These patients retained normal ranges of motion, and their average grip strength in the affected hand was restored to at least 85% of that of the other hand. CONCLUSIONS: According to the postoperative 25-36 months surgical results of our study, arthroscopic repair with adjuvant PRP injections is a satisfactory method of repairing early foveal tears of the TFCC and can enhance wrist function by relieving pain and increasing tolerance for work or sports.


Assuntos
Fibrocartilagem Triangular , Traumatismos do Punho , Adulto , Artroscopia/métodos , Feminino , Humanos , Masculino , Dor , Estudos Retrospectivos , Âncoras de Sutura , Resultado do Tratamento , Fibrocartilagem Triangular/lesões , Fibrocartilagem Triangular/cirurgia , Traumatismos do Punho/cirurgia
16.
J Hand Surg Am ; 47(6): 507-516, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35341629

RESUMO

PURPOSE: To compare the clinical outcomes of arthroscopically-assisted suture anchor repair and transosseous sutures for repair of foveal triangular fibrocartilage complex tears in patients with distal radioulnar joint (DRUJ) instability. METHODS: Sixty patients with triangular fibrocartilage complex foveal detachment associated with DRUJ instability were prospectively recruited and randomized into 2 equal groups-the anchor repair group and the transosseous repair group. The primary outcome was DRUJ function after 2 years, which was assessed by the DRUJ evaluating system. The secondary outcomes were grip strength, visual analog scale for pain, Mayo Modified Wrist ScorePatient-Rated Wrist Evaluation score, and the Disabilities of the Arm, Shoulder, and Hand score. RESULTS: There were no significant differences between the groups for any of the outcome measures. Good-to-excellent outcomes (according to the DRUJ evaluation system) were achieved in 27 (90%) patients in the anchor repair group and 26 (86.7%) patients in the transosseous repair group. Fewer complications were observed in the anchor repair group. CONCLUSIONS: Both techniques yielded good and comparable outcomes with a lesser incidence of early complications in the anchor repair group. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic II.


Assuntos
Instabilidade Articular , Fibrocartilagem Triangular , Traumatismos do Punho , Artroscopia/métodos , Humanos , Estudos Retrospectivos , Âncoras de Sutura , Suturas , Fibrocartilagem Triangular/cirurgia , Articulação do Punho/cirurgia
17.
J Shoulder Elbow Surg ; 31(4): 711-717, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34775037

RESUMO

BACKGROUND: One of the leading challenges for surgeons shifting to stemless anatomic total shoulder arthroplasty (TSA) is subscapularis repair. In the available literature reporting outcomes after stemless TSA, subscapularis tenotomy with side-to-side repair is the most common technique despite some concerns regarding this technique in the biomechanical and clinical literature. Accordingly, this study investigated subscapularis tenotomy repair with stemless TSA with 2 primary objectives: (1) to evaluate the subscapularis tendon dimensions with reference to subscapularis tenotomy to determine the amount of tendon remaining for side-to-side repair after shoulder arthroplasty and (2) to biomechanically compare 2 methods of subscapularis tenotomy repair after stemless TSA-side-to-side repair and anchor-based repair. METHODS: We used 12 male shoulder specimens for this study. To address our first objective, measurements were made to calculate the dimensions of the subscapularis tendon at the superior, middle, and inferior levels to determine the amount of tendon remaining after tenotomy. These specimens were then divided into 2 groups (n = 6 in each group) to biomechanically compare subscapularis tenotomy repair with (1) traditional side-to-side repair and (2) anchor-based repair. The shoulders then underwent biomechanical testing with primary outcomes including load to failure and cyclic displacement. RESULTS: The mean subscapularis tendon width measured from the medial insertion at the lesser tuberosity to the muscle-tendon junction varied depending on the level: 19.5 mm superiorly (95% confidence interval [CI], 16.2-22.8 mm); 18.3 mm at the midportion (95% CI, 13.6-23.0 mm); and 13.1 mm inferiorly (95% CI, 9.1-17.1 mm). With a tenotomy made 1 cm medial to the lesser tuberosity insertion, a mean of 3.1 mm of tendon remained medially at the inferior subscapularis, with one-third of specimens having no tendon left medially at this level. On comparison of tenotomy repair techniques, the anchor-based technique had a 57% higher ultimate load to failure compared with the side-to-side repair (448 N vs. 249 N, P < .001). There were no significant differences in cyclic displacement (6.1 mm vs. 7.1 mm, P = .751) and construct stiffness (38.1 N/mm vs. 42.9 N/mm, P = .461) between techniques. CONCLUSIONS: With traditional techniques for subscapularis tenotomy for anatomic TSA, there is very little tendon remaining inferiorly for side-to-side repair. When subscapularis tenotomy is performed for stemless TSA, a double-row anchor-based repair has a better time-zero ultimate load to failure compared with side-to-side repair.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Artroplastia do Ombro/métodos , Fenômenos Biomecânicos , Humanos , Masculino , Osteotomia/métodos , Manguito Rotador/cirurgia , Articulação do Ombro/cirurgia , Tenotomia/métodos
18.
J Shoulder Elbow Surg ; 31(5): e213-e222, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34687919

RESUMO

BACKGROUND: Little is known about the optimal tension in arthroscopic rotator cuff repair (ARCR). This study aimed to identify preoperative, intraoperative, and postoperative factors that correlate with the tension in ARCR and to determine the optimal intraoperative tension using Grasper Tensioning Attachment, a tension meter attached to the common arthroscopic surgical grasper. METHODS: This study included 63 patients with a mean age at surgery of 65.3 years (range, 45-83 years) who underwent ARCR. The mean follow-up period was 24.1 months (range, 24-28 months). We investigated the patients' demographic data, Japanese Orthopaedic Association score, DeOrio and Cofield classification, and Goutallier stage of the supraspinatus and infraspinatus muscles. We also evaluated cuff integrity based on the Sugaya classification via magnetic resonance imaging. The free edge of the torn retracted tendon was grasped, and the passive tension to the footprint was then measured with Grasper Tensioning Attachment with the arm at the side. The anteroposterior (AP) and mediolateral (ML) diameters were also measured. RESULTS: The preoperative Goutallier stage of the supraspinatus muscle was stage 0 in 7 cases, stage 1 in 34, stage 2 in 20, and stage 3 in 2. The mean intraoperative rotator repair tension was 10.0 ± 2.5 N (range, 7.5-17 N). The mean AP diameter of the rotator cuff tear was 22 ± 10 mm (range, 8-50 mm), and the mean ML diameter was 24 ± 10 mm (range, 10-50 mm). Age, DeOrio and Cofield classification, Goutallier stage, AP diameter, and ML diameter correlated with rotator repair tension. The rotator repair tension in Sugaya classification type III or IV cases (n = 12, 11.4 ± 2.4 N) was significantly larger than that in type I or II cases (n = 51, 9.7 ± 2.4 N; P = .03). Tension ≥ 10 N as a cutoff value from receiver operating characteristic curve analysis was a risk factor for poor cuff integrity (95% confidence interval, 0.53-0.88). CONCLUSIONS: Rotator repair tension ≥ 10 N was a risk factor for poor cuff integrity. Thus, care should be taken when performing intraoperative procedures and administering postoperative regimens.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador , Artroscopia/métodos , Humanos , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/cirurgia , Resultado do Tratamento
19.
Arch Orthop Trauma Surg ; 142(5): 835-844, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-33913009

RESUMO

PURPOSE: Aim of this systematic review was to analyze long-term results after meniscus refixation. METHODS: A systematic literature search was carried out in various databases on studies on long-term results after meniscus refixation with a minimum follow-up of 7 years. Primary outcome criterion was the failure rate. Secondary outcome criteria were radiological signs of osteoarthritis (OA) and clinical scores. RESULTS: A total of 12 retrospective case series (level 4 evidence) were identified that reported about failure rates of more than 7 years follow-up. There was no statistical difference in the failure rates between open repair, arthroscopic inside-out with posterior incisions and arthroscopic all-inside repair with flexible non-resorbable implants. In long-term studies that examined meniscal repair in children and adolescents, failure rates were significantly higher than in studies that examined adults. Six studies have shown minor radiological degenerative changes that differ little from the opposite side. The reported clinical scores at follow-up were good to very good. CONCLUSION: This systematic review demonstrates that good long-term outcomes can be obtained in patients after isolated meniscal repair and in combination with ACL reconstruction. With regard to the chondroprotective effect of meniscus repair, the long-term failure rate is acceptable. LEVEL OF EVIDENCE: IV.


Assuntos
Lesões do Ligamento Cruzado Anterior , Menisco , Lesões do Menisco Tibial , Adolescente , Adulto , Lesões do Ligamento Cruzado Anterior/cirurgia , Artroscopia/métodos , Criança , Humanos , Meniscos Tibiais/diagnóstico por imagem , Meniscos Tibiais/cirurgia , Menisco/cirurgia , Estudos Retrospectivos , Lesões do Menisco Tibial/cirurgia
20.
BMC Musculoskelet Disord ; 22(1): 74, 2021 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-33441126

RESUMO

BACKGROUND: Tibial intercondylar eminence avulsion fractures occur primarily in adolescents and young adults. However, the incidence of such fractures is increasing in adults, concurrent with an increase in sports injuries and traffic accidents. This study describes the fixation-based double-row anchor suture-bridge technique, a novel technique for treating tibial intercondylar eminence fractures in adults; and evaluates its preliminary clinical outcomes. METHODS: A retrospective evaluation of adult patients with tibial intercondylar eminence fractures treated at our institution from June 2016 to June 2018 was conducted. Seven such patients, treated with the anchor suture-bridge technique, were included. All patients were assessed for knee joint range of motion (ROM), Lysholm knee score, International Knee Documentation Committee (IKDC) Subjective Knee Evaluation Form score, Tegner activity score pre-surgery, and the healing of the fracture at 3, 6 and 12 months minimal post-surgery follow-up. RESULTS: Patients were followed for a mean of 12.43 months (range 9-15 months). By the final follow-up, all fractures had fully healed. The mean Lysholm score improved from 27.86 (range, 2 to 54) pre-surgery to 88.14 (range, 81 to 100) 3 months post-surgery (p < 0.05). Similarly, the mean IKDC score improved from 48.86 (range, 43 to 55) to 84.29 (range, 75 to 90) (P < 0.05); and the mean Tegner activity score improved from 1.71 (range, 0 to 4) to 3.29 (range, 2 to 4) (p < 0.05). Furthermore, knee joint ROM, Lysholm scores, IKDC scores, and Tegner activity scores displayed excellent outcomes at the 6 and 12 months minimal follow-up. CONCLUSION: The arthroscopic anchor suture-bridge technique is a valid and secure method for achieving effective fixation of tibial intercondylar eminence fractures in adults.


Assuntos
Fraturas da Tíbia , Adolescente , Artroscopia , Seguimentos , Fixação Interna de Fraturas , Humanos , Articulação do Joelho/cirurgia , Estudos Retrospectivos , Técnicas de Sutura , Suturas , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA