1.
Dev Psychopathol ; : 1-17, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38465371

RESUMO

We took a multilevel developmental contextual approach and characterized trajectories of alcohol misuse from adolescence through early midlife, examined genetic and environmental contributions to individual differences in those trajectories, and identified adolescent and young adult factors associated with change in alcohol misuse. Data were from two longitudinal population-based studies. FinnTwin16 is a study of Finnish twins assessed at 16, 17, 18, 25, and 35 years (N = 5659; 52% female; 32% monozygotic). The National Longitudinal Study of Adolescent to Adult Health (Add Health) is a study of adolescents from the United States, who were assessed at five time points from 1994 to 2018 (N = 18026; 50% female; 64% White, 21% Black, 4% Native American, 7% Asian, 9% Other race/ethnicity). Alcohol misuse was measured as frequency of intoxication in FinnTwin16 and frequency of binge drinking in Add Health. In both samples, trajectories of alcohol misuse were best described by a quadratic growth curve: Alcohol misuse increased across adolescence, peaked in young adulthood, and declined into early midlife. Individual differences in these trajectories were primarily explained by environmental factors. Several adolescent and young adult correlates were related to the course of alcohol misuse, including other substance use, physical and mental health, and parenthood.

2.
BMC Ophthalmol ; 24(1): 207, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38711043

RESUMO

PURPOSE: To understand the ocular biometric parameters characteristics and refractive errors in 3-to 6-year-old preschool children in Chengdu, China, and to investigate the prevalence of refractive errors. METHOD: A school-based cross-sectional study was conducted in Chengdu from 2020 to2022 with a total of 666 kindergartens. All children were measured by non-cycloplegic autorefraction and uncorrected visual acuity (UCVA) and ocular biometric parameters. Finally, univariate linear regression models were used to analyze the relationship between ocular biometric parameters and refraction. RESULTS: A total of 108,578 preschool children aged 3-6 underwent examinations, revealing a myopia prevalence of 6.1%. The mean axial length (AL), keratometry (K), corneal radius (CR), axial length/corneal radius (AL/CR) Ratio, central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), and vitreous chamber depth (VCD) were 22.35 ± 0.69 mm, 43.35 ± 1.58 D, 7.80 ± 0.28 mm, 2.87 ± 0.08, 533.31 ± 32.51 µm, 2.70 ± 0.28 mm, 3.91 ± 0.27 mm, and 15.20 ± 0.68 mm, respectively. With increasing age, AL, CR, AL/CR ratio, CCT, ACD, LT, and VCD also increased. Regardless of age, males consistently exhibited longer AL, flatter corneal curvature, shallower ACD, thicker CCT, thinner LT, and longer VCD compared to females. AL, K, CR, LT, and VCD all showed significant linear relationships with SE (all P < 0.001) in univariate linear regression analysis after adjusting for gender and age. CONCLUSION: The prevalence of myopia among preschool children aged 3-6 in Chengdu is relatively low. Ocular biometric parameters affecting refractive errors include AL, K, CR, LT, and VCD. The preschool period serves as a critical phase for myopia prevention and control.


Assuntos
Biometria , Refração Ocular , Acuidade Visual , Humanos , Feminino , Masculino , Estudos Transversais , China/epidemiologia , Refração Ocular/fisiologia , Pré-Escolar , Criança , Acuidade Visual/fisiologia , Prevalência , Comprimento Axial do Olho , Córnea/patologia , Córnea/anatomia & histologia , Erros de Refração/epidemiologia , Erros de Refração/fisiopatologia , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/patologia , Miopia/epidemiologia , Miopia/fisiopatologia
3.
Clin Exp Ophthalmol ; 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38803136

RESUMO

BACKGROUND: To compare intraocular pressure (IOP) and anterior segment parameters between eyes with unilateral primary angle closure glaucoma (PACG) and their fellow eyes with primary angle closure (PAC) or primary angle closure suspect (PACS). METHODS: Subjects underwent anterior segment imaging using 360-degree swept-source optical coherence tomography (SS-OCT, CASIA Tomey, Nagoya, Japan) and ocular investigations including gonioscopy and IOP measurement. Each SS-OCT scan (divided into 8 frames, 22.5 degrees apart) was analysed and an average was obtained for the following anterior segment parameters: iridotrabecular contact (ITC), angle opening distance (AOD750), iris thickness and curvature, anterior chamber width, depth and area (ACW, ACD and ACA) and lens vault (LV). RESULTS: Among 132 unilateral PACG subjects (mean age: 62.91 ± 7.2 years; 59.1% male), eyes with PACG had significantly higher presenting IOP (24.81 ± 0.94 vs. 18.43 ± 0.57 mmHg, p < 0.001), smaller gonioscopic Shaffer grade (2.07 ± 0.07 vs. 2.31 ± 0.07, p < 0.001) and a greater extent of peripheral anterior synechiae (PAS, 1.21 ± 0.21 vs. 0.54 ± 0.16 clock hours, p = 0.001). PACG eyes also exhibited increased ITC, ITC area, greater LV and smaller AOD750, ACD and ACA (all p < 0.05). Using the forward stepwise regression model, an increase in 1 mmHg in presenting IOP before laser peripheral iridotomy (LPI) increases the odds of having PACG by 9% (95% confidence interval 5%-14%). CONCLUSIONS: PACG eyes have higher presenting IOP, smaller anterior segment parameters, greater extent of PAS, and larger LV compared to their fellow eyes with angle closure. Narrower anterior chamber dimensions and higher presenting IOP before LPI may increase risk of chronic elevated IOP and glaucomatous optic neuropathy after LPI.

4.
J Dairy Res ; : 1-4, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38812402

RESUMO

The objective of the present study was to evaluate the relationship between body weight (BW) and hip width (HW) in dairy buffaloes (Bubalus bubalis). HW was measured in 215 Murrah buffaloes with a BW of 341 ± 161.6 kg, aged between three months and five years, and raised in southeastern Mexico. Linear and non-linear regressions were used to construct the prediction models. The goodness of fit of the models was evaluated using the Akaike information criterion (AIC), Bayesian information criterion (BIC), coefficient of determination (R2), mean squared error (MSE), and root MSE (RMSE). Additionally, the developed models were evaluated through internal and external cross-validation (k-folds) using independent data. The ability of the fitted models to predict the observed values was assessed based on the root mean square error of prediction (RMSEP), R2, and mean absolute error (MAE). The relationship between BW and HW showed a high correlation coefficient (r = 0.96, P < 0.001). The chosen fitted model to predict BW was: -176.33 (± 40.83***) + 8.74 (± 1.79***) × HW + 0.04 (± 0.01*) × HW2, because it presented the lowest MSE, RMSE, and AIC values, which were 1228.64, 35.05 and 1532.41, respectively. Therefore, with reasonable accuracy, the quadratic model using hip width may be suitable for predicting body weight in buffaloes.

5.
Int J Phytoremediation ; 26(5): 773-783, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37814784

RESUMO

Tailings and mine dumps are often pollutant sources that pose serious environmental threats to surrounding areas. The use of pioneer vascular plants to extract or stabilize metals is considered among the more effective mine tailing reclamation techniques. The study aimed at evaluating the phytoremediation potential of Pinus halepensis in abandoned mine-tailing (SW-Sardinia, Italy). Plant ability to tolerate high Zn, Pb, and Cd concentration and their accumulation in roots and aerial parts were assessed at greenhouse conditions. Experiments were performed on 45 seedlings planted in different substrates (mine-tailings, mine-tailings compost-amended, and reference) and on 15 seedlings grown spontaneously in the contaminated mine site investigated with their own substrates. The phytostabilization potential of plant was evaluated through biological accumulation and translocation indexes together with plant survival and biometric parameters. The outcomes showed the adaptability of P. halepensis to grow and survive in contaminated substrates. Compost addition did not improve plant survival and growth, however, it enhanced total carbon and nitrogen contents of soil, restricted metal bioavailability, and accumulation in plant aerial parts. These findings highlight that P. halepensis may be considered for phytostabilization given the great potential to limit Zn, Pb, and Cd toxicity in plant tissues by applying compost amendment in metal contaminated mine sites.


The novelty of this study is the selection of Pinus halepensis Mill. as a proper tree species for long-term phytoremediation of multi-heavy metal mine tailing sites. This plant species not only had adaptation to the Mediterranean climate and could tolerate high temperatures and high metal concentrations, but also showed high survival and growth percentage of its roots and epigean organs in highly contaminated mine tailing. Pinus halepensis could limit metal accumulation and toxicity in the aerial part of the plant with the addition of compost amendment. This study demonstrates that compost can enhance soil properties and modify metal bioavailability. The outcomes can be beneficial for the phytostabilization project and restoration of similar Mediterranean mine sites.


Assuntos
Metais Pesados , Pinus , Poluentes do Solo , Biodegradação Ambiental , Cádmio , Árvores , Chumbo , Poluentes do Solo/análise , Plantas , Solo/química , Metais Pesados/análise
6.
Sensors (Basel) ; 24(11)2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38894368

RESUMO

Internet of Things (IoT) technology is evolving over the peak of smart infrastructure with the participation of IoT devices in a wide range of applications. Traditional IoT authentication methods are vulnerable to threats due to wireless data transmission. However, IoT devices are resource- and energy-constrained, so building lightweight security that provides stronger authentication is essential. This paper proposes a novel, two-layered multi-factor authentication (2L-MFA) framework using blockchain to enhance IoT devices and user security. The first level of authentication is for IoT devices, one that considers secret keys, geographical location, and physically unclonable function (PUF). Proof-of-authentication (PoAh) and elliptic curve Diffie-Hellman are followed for lightweight and low latency support. Second-level authentication for IoT users, which are sub-categorized into four levels, each defined by specific factors such as identity, password, and biometrics. The first level involves a matrix-based password; the second level utilizes the elliptic curve digital signature algorithm (ECDSA); and levels 3 and 4 are secured with iris and finger vein, providing comprehensive and robust authentication. We deployed fuzzy logic to validate the authentication and make the system more robust. The 2L-MFA model significantly improves performance, reducing registration, login, and authentication times by up to 25%, 50%, and 25%, respectively, facilitating quicker cloud access post-authentication and enhancing overall efficiency.

7.
Sensors (Basel) ; 24(13)2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-39000946

RESUMO

Personal identification systems based on electroencephalographic (EEG) signals have their own strengths and limitations. The stability of EEG signals strongly affects such systems. The human emotional state is one of the important factors that affects EEG signals' stability. Stress is a major emotional state that affects individuals' capability to perform day-to-day tasks. The main objective of this work is to study the effect of mental and emotional stress on such systems. Two experiments have been performed. In the first, we used hand-crafted features (time domain, frequency domain, and non-linear features), followed by a machine learning classifier. In the second, raw EEG signals were used as an input for the deep learning approaches. Different types of mental and emotional stress have been examined using two datasets, SAM 40 and DEAP. The proposed experiments proved that performing enrollment in a relaxed or calm state and identification in a stressed state have a negative effect on the identification system's performance. The best achieved accuracy for the DEAP dataset was 99.67% in the calm state and 96.67% in the stressed state. For the SAM 40 dataset, the best accuracy was 99.67%, 93.33%, 92.5%, and 91.67% for the relaxed state and stress caused by identifying mirror images, the Stroop color-word test, and solving arithmetic operations, respectively.


Assuntos
Eletroencefalografia , Estresse Psicológico , Humanos , Eletroencefalografia/métodos , Estresse Psicológico/fisiopatologia , Estresse Psicológico/diagnóstico , Masculino , Processamento de Sinais Assistido por Computador , Adulto , Feminino , Emoções/fisiologia , Aprendizado de Máquina , Adulto Jovem , Aprendizado Profundo
8.
Sensors (Basel) ; 24(9)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38732954

RESUMO

Biometric fingerprint identification hinges on the reliability of its sensors; however, calibrating and standardizing these sensors poses significant challenges, particularly in regards to repeatability and data diversity. To tackle these issues, we propose methodologies for fabricating synthetic 3D fingerprint targets, or phantoms, that closely emulate real human fingerprints. These phantoms enable the precise evaluation and validation of fingerprint sensors under controlled and repeatable conditions. Our research employs laser engraving, 3D printing, and CNC machining techniques, utilizing different materials. We assess the phantoms' fidelity to synthetic fingerprint patterns, intra-class variability, and interoperability across different manufacturing methods. The findings demonstrate that a combination of laser engraving or CNC machining with silicone casting produces finger-like phantoms with high accuracy and consistency for rolled fingerprint recordings. For slap recordings, direct laser engraving of flat silicone targets excels, and in the contactless fingerprint sensor setting, 3D printing and silicone filling provide the most favorable attributes. Our work enables a comprehensive, method-independent comparison of various fabrication methodologies, offering a unique perspective on the strengths and weaknesses of each approach. This facilitates a broader understanding of fingerprint recognition system validation and performance assessment.

9.
Sensors (Basel) ; 24(9)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38732856

RESUMO

Biometric authentication plays a vital role in various everyday applications with increasing demands for reliability and security. However, the use of real biometric data for research raises privacy concerns and data scarcity issues. A promising approach using synthetic biometric data to address the resulting unbalanced representation and bias, as well as the limited availability of diverse datasets for the development and evaluation of biometric systems, has emerged. Methods for a parameterized generation of highly realistic synthetic data are emerging and the necessary quality metrics to prove that synthetic data can compare to real data are open research tasks. The generation of 3D synthetic face data using game engines' capabilities of generating varied realistic virtual characters is explored as a possible alternative for generating synthetic face data while maintaining reproducibility and ground truth, as opposed to other creation methods. While synthetic data offer several benefits, including improved resilience against data privacy concerns, the limitations and challenges associated with their usage are addressed. Our work shows concurrent behavior in comparing semi-synthetic data as a digital representation of a real identity with their real datasets. Despite slight asymmetrical performance in comparison with a larger database of real samples, a promising performance in face data authentication is shown, which lays the foundation for further investigations with digital avatars and the creation and analysis of fully synthetic data. Future directions for improving synthetic biometric data generation and their impact on advancing biometrics research are discussed.


Assuntos
Face , Jogos de Vídeo , Humanos , Face/anatomia & histologia , Face/fisiologia , Biometria/métodos , Identificação Biométrica/métodos , Imageamento Tridimensional/métodos , Masculino , Feminino , Algoritmos , Reprodutibilidade dos Testes
10.
Sensors (Basel) ; 24(15)2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39123851

RESUMO

This work presents a novel approach to enhancing iris recognition systems through a two-module approach focusing on low-level image preprocessing techniques and advanced feature extraction. The primary contributions of this paper include: (i) the development of a robust preprocessing module utilizing the Canny algorithm for edge detection and the circle-based Hough transform for precise iris extraction, and (ii) the implementation of Binary Statistical Image Features (BSIF) with domain-specific filters trained on iris-specific data for improved biometric identification. By combining these advanced image preprocessing techniques, the proposed method addresses key challenges in iris recognition, such as occlusions, varying pigmentation, and textural diversity. Experimental results on the Human-inspired Domain-specific Binarized Image Features (HDBIF) Dataset, consisting of 1892 iris images, confirm the significant enhancements achieved. Moreover, this paper offers a comprehensive and reproducible research framework by providing source codes and access to the testing database through the Notre Dame University dataset website, thereby facilitating further application and study. Future research will focus on exploring adaptive algorithms and integrating machine learning techniques to improve performance across diverse and unpredictable real-world scenarios.


Assuntos
Algoritmos , Identificação Biométrica , Processamento de Imagem Assistida por Computador , Iris , Iris/diagnóstico por imagem , Humanos , Identificação Biométrica/métodos , Processamento de Imagem Assistida por Computador/métodos , Biometria/métodos , Bases de Dados Factuais , Aprendizado de Máquina
11.
Sensors (Basel) ; 24(6)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38544258

RESUMO

Speaker recognition is a challenging problem in behavioral biometrics that has been rigorously investigated over the last decade. Although numerous supervised closed-set systems inherit the power of deep neural networks, limited studies have been made on open-set speaker recognition. This paper proposes a self-supervised open-set speaker recognition that leverages the geometric properties of speaker distribution for accurate and robust speaker verification. The proposed framework consists of a deep neural network incorporating a wider viewpoint of temporal speech features and Laguerre-Voronoi diagram-based speech feature extraction. The deep neural network is trained with a specialized clustering criterion that only requires positive pairs during training. The experiments validated that the proposed system outperformed current state-of-the-art methods in open-set speaker recognition and cluster representation.

12.
J Clin Ultrasound ; 52(6): 680-686, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38587238

RESUMO

OBJECTIVE: To evaluate the association between Doppler patterns in fetuses with Down syndrome (DS) and their placental histopathologic findings. METHODS: A retrospective cross-sectional study was performed by collecting data from medical records of singleton pregnancies between January 2014 and January 2022, whose fetuses had a confirmed diagnosis of DS either prenatally or postnatally. Placental histopathology, maternal characteristics, and prenatal ultrasound (biometric parameters and umbilical artery [UA] Doppler) were evaluated. RESULTS: Of 69 eligible pregnant women, 61 met the inclusion and exclusion criteria. In the sample, 15 fetuses had an estimated fetal weight < 10th percentile for gestational age (GA) and were considered small for gestational age (SGA). Thirty-eight fetuses had increased resistance on the UA Doppler. Histologic changes were detected in 100% of the placentas, the most common being delayed villous maturation, alterations associated with poor fetal vascular perfusion, and villous dysmorphism. More than 50% of the placentas showed alterations related to placental insufficiency. We did not observe a statistically significant association between UA Doppler examination and placental alterations. All placentas analyzed in the SGA subgroup showed findings compatible with placental insufficiency. CONCLUSION: We found no statistically significant association between placental histopathologic findings and UA Doppler abnormalities in fetuses with DS. The placental alterations identified were delayed villous maturation, alterations associated with poor fetal vascular perfusion, and villous dysmorphism.


Assuntos
Síndrome de Down , Placenta , Ultrassonografia Pré-Natal , Humanos , Feminino , Síndrome de Down/diagnóstico por imagem , Síndrome de Down/complicações , Síndrome de Down/fisiopatologia , Gravidez , Estudos Transversais , Estudos Retrospectivos , Ultrassonografia Pré-Natal/métodos , Adulto , Placenta/diagnóstico por imagem , Placenta/patologia , Placenta/irrigação sanguínea , Hemodinâmica/fisiologia , Ultrassonografia Doppler/métodos , Artérias Umbilicais/diagnóstico por imagem , Artérias Umbilicais/fisiopatologia , Feto/diagnóstico por imagem
13.
Fish Physiol Biochem ; 50(4): 1461-1481, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38722480

RESUMO

This study evaluated the use of essential oil of Ocimum gratissimum (EOOG) for anesthesia and in transport of Colossoma macropomum. Experiment 1, Test 1, anesthesia induction and recovery times were determined using different EOOG concentrations (0, 20, 50, 100, 200, 300 mg L-1), with two size classes: Juveniles I (0.86 g) and Juveniles II (11.46 g) (independent tests in a completely randomized design). Based on the results of Test 1, in Test 2 Juveniles II were exposed to EOOG concentrations: 0, 20, 100 mg L-1. Tissue samples were collected immediately after induction and 1 h post-recovery, to assess oxidative status variables. Experiment 2, Juveniles I (0.91 g) and Juveniles II (14.76 g) were submitted to transport in water with different concentrations of EOOG (0, 5, 10 mg L-1) (independent tests in a completely randomized design). The effects on oxidative status variables were evaluated. Concentrations between 50 and 200 mg L-1 EOOG can be indicated for Juveniles I, while concentrations between 50 and 100 mg L-1 EOOG for Juveniles II. The concentration of 100 mg L-1 EOOG was able to prevent oxidative damage in the liver. In Experiment 2, the concentrations of 5 and 10 mg L-1 EOOG added to the transport water caused sedation for both studied size classes of juveniles and did not cause oscillations in water quality variables nor any mortality. The concentration of 10 mg L-1 EOOG improved the oxidative status. It can be concluded that EOOG can be used for anesthesia and transport of C. macropomum.


Assuntos
Ocimum , Óleos Voláteis , Animais , Óleos Voláteis/farmacologia , Ocimum/química , Estresse Oxidativo/efeitos dos fármacos , Caraciformes , Anestesia/veterinária , Fígado/metabolismo , Fígado/efeitos dos fármacos
14.
Surg Radiol Anat ; 46(5): 585-593, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38429405

RESUMO

PURPOSE: Keeping the head in a neutral position is requisite for glasses/lenses/head-up designs, the suitability of oculo-plastic surgery and for the grading the eye shift. Anatomically incompatible glasses are one of the common problems affecting accommodation, reducing comfort and disturbing by causing symptoms such as dizziness and nausea. The oculo-palpebral measurements act as a key determinant in symmetrical facial attractiveness. This study aims to investigate the most effective oculo-palpebral landmarks, head-neutral as the ideal position, taking into account of individual anatomical differences of these patients. METHODS: 100 females and 100 males aged between 18 and 20 years were photographed. Digital photogrammetric measurements were made with the ImageJ program. Interpupillary and interhelical distances, besides bilateral palpebral fissure length and height, and iris diameter were calculated on front-facing photographs. RESULTS: Mean interpupillary distance was measured wider in males than in females. The mean length of palpebral fissure was 31 mm; palpebral fissure height was 10 mm. These figures were valid in both eyes and gender. The interhelical distance was calculated as the mean and was measured longer in men. Since the measurement values were the same in both sexes and on both sides, they were determined as important landmarks for controlling the head-neutral position, evaluating whether there was a deviation in the eye, and measuring the numerical value when detected. CONCLUSION: It is essential to check the side-symmetry of the patient's palpebral fissure height, palpebral fissure length, diameter of iris and corneal depth during oculo-plastic invention and artificial design.


Assuntos
Pontos de Referência Anatômicos , Cabeça , Humanos , Masculino , Feminino , Adulto Jovem , Adolescente , Cabeça/anatomia & histologia , Pálpebras/anatomia & histologia , Postura , Fotografação , Posicionamento do Paciente , Fotogrametria/métodos , Olho/anatomia & histologia
15.
Int Ophthalmol ; 44(1): 2, 2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38315421

RESUMO

PURPOSE: To investigate the acute effects of upper eyelid blepharoplasty on intraocular pressure (IOP) and ocular biometric parameters. METHOD: This prospective cross sectional study examined the eyes of 49 patients with dermatochalasis. Following a detailed ophthalmological examination, corneal topography was used to evaluate the eyes mesopic and photopic pupil diameter, anterior chamber depth, and corneal astigmatism on the day of surgery and on days first and seventh postoperatively. Ocular biometry was used to assess axial length and intraocular lens power. Goldmann applanation tonometry was used to measure intraocular pressure. RESULTS: Forty-nine eyes (26 males and 23 females) of 49 patients aged between 44 and 76 years (mean 61 ± 7.9) were included in our study. The mean anterior chamber depth (ACD) was 2.90 ± 0.37 mm preoperatively, 3.00 ± 0.29 mm at postoperative day first, and 3.04 ± 0.29 mm at postoperative day seventh, and the increase in anterior chamber depth was statistically significant (p < 0.001). The mean astigmatism values were measured as preoperative 0.73 ± 0.69 D, postoperative first day 0.93 ± 0.81 D, and postoperative seventh day 1.26 ± 0.90 D. The increase in astigmatism values was statistically significant (p < 0.001). The mean pupil diameter measurements in the mesopic environment were 4.20 ± 0.61 mm preoperatively, 4.40 ± 0.59 mm on the first postoperative day, and 4.39 ± 0.57 mm on the seventh postoperative day, and there was a statistically significant difference between the three measurements (p = 0.03). The mean IOP measurements of the patients were 15.91 ± 3.51 mmHg preoperatively, 16.81 ± 3.36 mmHg on the first postoperative day, and 16.97 ± 3.13 mmHg on the seventh postoperative day. The increase between these three measurements was statistically significant (p = 0.013). CONCLUSION: This study includes important insights into the potential acute phase impact of blepharoplasty surgery on ocular findings. Patients undergoing upper eyelid surgery should be informed about the possible change in ocular biometric parameters, intraocular pressure, and pupil diameter.


Assuntos
Astigmatismo , Blefaroplastia , Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Pressão Intraocular , Astigmatismo/diagnóstico , Astigmatismo/etiologia , Estudos Prospectivos , Estudos Transversais , Implante de Lente Intraocular , Pálpebras/cirurgia , Biometria
16.
Annu Rev Biomed Eng ; 24: 1-27, 2022 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-34932906

RESUMO

Mounting clinical evidence suggests that viral infections can lead to detectable changes in an individual's normal physiologic and behavioral metrics, including heart and respiration rates, heart rate variability, temperature, activity, and sleep prior to symptom onset, potentially even in asymptomatic individuals. While the ability of wearable devices to detect viral infections in a real-world setting has yet to be proven, multiple recent studies have established that individual, continuous data from a range of biometric monitoring technologies can be easily acquired and that through the use of machine learning techniques, physiological signals and warning signs can be identified. In this review, we highlight the existing knowledge base supporting the potential for widespread implementation of biometric data to address existing gaps in the diagnosis and treatment of viral illnesses, with a particular focus on the many important lessons learned from the coronavirus disease 2019 pandemic.


Assuntos
COVID-19 , Dispositivos Eletrônicos Vestíveis , Biometria , COVID-19/diagnóstico , Humanos
17.
Strahlenther Onkol ; 2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37713170

RESUMO

PURPOSE: Patient misidentification in radiation oncology (RO) is a significant concern due to the potential harm to patient health and the burden on healthcare systems. Electronic patient identification systems (ePIS) are increasingly being used as an alternative or supplement to organizational systems (oPIS). The objective of this study was to assess the usability and usefulness of ePIS and oPIS in German-speaking countries. METHODS: A cross-sectional survey was designed by a group of experts from various professional backgrounds in RO. The survey consisted of 38 questions encompassing quantitative and qualitative data on usability, user experience, and usefulness of PIS. It was available between August and October 2022. RESULTS: Of 118 eligible participants, 37% had implemented some kind of ePIS. Overall, 22% of participants who use an oPIS vs. 10% of participants who use an ePIS reported adverse events in terms of patients' misidentification in the past 5 years. Frequent or very frequent drop-outs of electronic systems were reported by 31% of ePIS users. Users of ePIS significantly more often affirmed a positive cost-benefit ratio of ePIS as well as an improvement of workflow, whereas users of oPIS more frequently apprehended a decrease in staffs' attention through ePIS. The response rate was 8%. CONCLUSION: The implementation of ePIS can contribute to efficient PI and improved processes. Apprehensions by oPIS users and assessments of ePIS users differ significantly in aspects of the perceived usefulness of ePIS. However, technical problems need to be addressed to ensure the reliability of ePIS. Further research is needed to assess the impact of different PIS on patient safety in RO.

18.
Exp Eye Res ; 235: 109619, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37633324

RESUMO

PURPOSE: To investigate the impact of different duration of blue light exposure on ocular parameters and choroidal blood perfusion in guinea pigs with lens-induced myopia. METHOD: Three-week-old Guinea pigs were randomly assigned to different light-environment groups. All groups were subjected to 12-h light/dark cycle. The control (NC) group was conditioned without intervention. While lens-induced myopia (LIM) groups had a -10D lens placed in the right eye and 0D in the left eye. The guinea pigs were exposed to increasing periods of blue-light (420 nm) environment for 3,6,9,12 h per day. Changes in refraction, axial length (AL), the radius of corneal curvature (CCR), choroidal thickness (ChT), and choroidal blood perfusion (ChBP)were measured in both LIM-eye and fellow-eye during the second and fourth week of LIM duration. RESULTS: During the first two weeks of the experiment, blue light exposure raised ChBP and ChT, and the effect of suppressing myopia was proportional to the duration of blue light exposure. However, in the fourth week of the experiment, prolonged blue light (12BL) exposure led to a reduction in retinal thickness and the increase in ChT and ChBP ceased. Shorter blue light exposure had a better effect on myopia suppression, with all blue light groups statistically different from the LIM group. CONCLUSION: Exposure to blue-light appears to have the potential to improve ChBP and ChT, thereby inhibiting the development of myopia. we speculate that blue-light inhibits the development of myopia for reasons other than longitudinal chromatic aberration (LCA). However,long-term exposure to blue-light may have adverse effects on ocular development. The next step is to investigate in depth the mechanisms by which the rational use of blue light regulates choroidal blood flow, offering new hope for the treatment of myopia.


Assuntos
Miopia , Animais , Cobaias , Corioide , Modelos Animais de Doenças , Luz , Miopia/etiologia , Perfusão , Refração Ocular
19.
J Child Psychol Psychiatry ; 64(1): 59-70, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35831875

RESUMO

BACKGROUND: Preschoolers' temperament characteristics are associated with children's long-term development. Such links underscore the importance of understanding factors that shape temperament during preschool. This is the first study to examine genetic and environmental sources of developmental growth in three temperament dimensions: surgency, negative affectivity, and effortful control, during the preschool period. METHODS: Biometric latent growth curve modeling was used to examine genetic, shared, and nonshared environmental contributions to the invariant level of and developmental growth in temperament, using a sample of 310 same-sex twin pairs (MZ = 123, DZ = 187) assessed at 3, 4, and 5 years of age. Temperament was assessed using primary caregiver's report on the Child Behavior Questionnaire-Short Form. RESULTS: All three temperament dimensions demonstrated linear increases from ages 3 to 5 years. The invariant levels of all three temperament dimensions were explained by genetic and nonshared environmental factors. Growth in surgency was fully explained by nonshared environmental factors, while growth in negative affectivity was mainly explained by genetic factors. Growth in effortful control was explained by genetic and nonshared environmental factors, although neither were significant due to large bootstrap standard errors. For negative affectivity and effortful control, the genetic factors that contributed to developmental growth were independent from those associated with their invariant levels. CONCLUSIONS: Collectively, these findings indicate that both genetic and nonshared environmental factors play important roles in the invariant levels of temperament. Findings also accord a critical role of children's nonshared environment in the development of surgency and to a lesser extent negative affectivity and effortful control. It is also notable that novel genetic effects contribute to developmental growth in negative affectivity and effortful control as children age, emphasizing the importance of integrating developmental models in genetic research.


Assuntos
Comportamento Problema , Temperamento , Criança , Pré-Escolar , Humanos , Comportamento Infantil , Gêmeos , Inquéritos e Questionários
20.
BMC Ophthalmol ; 23(1): 472, 2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-37990308

RESUMO

BACKGROUND: Refractive errors are one of the most common ocular conditions among children and adolescents, with myopia showing an increasing prevalence and early onset in this population. Recent studies have identified a correlation between refractive errors and ocular biometric parameters. METHODS: A systematic search was conducted in electronic databases including PubMed, EMBASE, Cochrane Library, Web of Science, and Medline from January 1, 2012, to May 1, 2023. Various ocular biometric parameters were summarized under different refractive states, including axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), corneal curvature (CC), Corneal curvature radius (CR),axial length-to-corneal radius ratio (AL/CR ratio), choroidal thickness (ChT), retinal thickness (RT), retinal nerve fiber layer thickness (RNFL), and retinal blood density (VD). The differences in these parameters among different refractive states were analyzed using Stata software with fixed or random-effects models, taking into account the assessed heterogeneity level. RESULTS: This meta-analysis included a total of 69 studies involving 128,178 eyes, including 48,795 emmetropic eyes, 60,691 myopic eyes, 13,983 hyperopic eyes, 2,040 low myopic eyes, 1,201 moderate myopic eyes, and 1,468 high myopic eyes. The results of our study demonstrated that, compared to the control group (emmetropic group), the myopic group and low, moderate, and high myopic groups showed significant increases in AL, AL/CR ratio, and ACD, while the hyperopic group exhibited significant decreases. Compared to the control group, the myopic group had a significantly increase for CC, while CR, CCT, perifoveal RT, subfoveal ChT, foveal ChT, parafoveal ChT, perifoveal (except nasal) ChT, and pRNFL (except temporal) significantly decreased. Compared to the control group, the hyperopic group had a significantly increase for subfoveal ChT, foveal ChT, parafoveal ChT, perifoveal ChT, and nasal pRNFL. Compared to the control group, the low and moderate myopic groups had a significantly decreases for the CCT, parafoveal RT (except nasal), perifoveal RT (except nasal), and pRNFL (except superior and temporal). Compared to the control group, the high myopic group had a significantly increase for CR, while LT, perifoveal ChT (except nasal), parafoveal RT, perifoveal RT, and pRNFL (except temporal) had significant decreased. CONCLUSION: The changes of ocular biometric parameters in children and adolescents are closely related to refractive errors. Ocular biometric parameters devices, as effective non-invasive techniques, provide objective biological markers for monitoring refractive errors such as myopia.


Assuntos
Hiperopia , Miopia , Erros de Refração , Humanos , Criança , Adolescente , Tomografia de Coerência Óptica/métodos , Retina , Refração Ocular , Biometria/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA