Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 308
Filtrar
1.
Eur Heart J ; 45(28): 2519-2532, 2024 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-38820201

RESUMO

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.


Assuntos
Endocardite , Falha de Prótese , Infecções Relacionadas à Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/mortalidade , Endocardite/cirurgia , Endocardite/mortalidade , Remoção de Dispositivo , Próteses Valvulares Cardíacas/efeitos adversos , Bioprótese/efeitos adversos , Resultado do Tratamento , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
2.
Artigo em Inglês | MEDLINE | ID: mdl-39087728

RESUMO

BACKGROUND: Transcatheter tricuspid valve-in-valve (ViV) replacement has yielded good hemodynamic outcomes in the treatment of dysfunctional bioprosthetic valves (BPVs). Intentional fracture of certain rigid BPV frames, if feasible, allows a larger implanted valve when compared with implant into an unfractured BPV. There remains limited data on the feasibility of tricuspid valve frame fracture. AIMS: Evaluate the feasibility of transcatheter tricuspid ViV replatement with fracture of the underlying BPV ring. METHODS: An international multicenter registry of tricuspid ViV replacement with intentional tricuspid valve frame fracture was created. Demographic data along with procedural characteristics, outcomes, and follow-up data were collected. Comparison was made to the pre- and post-ViV replacement with fracture of the tricuspid valve frame conditions. RESULTS: Ten patients from six centers were included with a median age and weight of 29 years and 67.3 kg respectively. Tricuspid valve frame fracture was performed using a median balloon diameter 3 mm (IQR 3-5) larger than the true inner diameter (ID). The final ID was a mean of 1.5 mm (95% CI: 0.35, 2.64: p < 0.05), and median 1.1 mm (0.5, 2.1) larger than the reported true ID of the surgical BPV after ViV replacement. The mean tricuspid inflow gradient by echocardiogram decreased by 6.65 mmHg (95% CI: 4.14, 9.15: p < 0.001). All procedures were without complication, specifically there was no heart block, pericardial effusion, or right coronary disruption. CONCLUSION: Intentional tricuspid valve frame fracture with tricuspid ViV replacement is feasible and can increase the valve orifice potentially reducing the risk of ViV patient prosthesis mismatch and is not associated with significant complications.

3.
Catheter Cardiovasc Interv ; 103(6): 1069-1073, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38584521

RESUMO

An 86-year-old female with history of surgical aortic valve replacement presented with clinical signs of heart failure. Echocardiography revealed a reduction in left ventricular systolic function and severe bioprosthetic aortic valve dysfunction. This is the first reported case of valve-in-valve transcatheter aortic valve replacement with concomitant undermining iatrogenic coronary obstruction with radiofrequency needle procedure in a surgical bioprosthetic valve.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Doença Iatrogênica , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Ablação por Cateter/efeitos adversos , Falha de Prótese , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/terapia , Agulhas , Função Ventricular Esquerda , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Oclusão Coronária/terapia , Oclusão Coronária/fisiopatologia , Angiografia Coronária
4.
Artigo em Inglês | MEDLINE | ID: mdl-38913220

RESUMO

BACKGROUND AND PURPOSE: Anticoagulant therapy with vitamin K antagonists is recommended within 3 to 6 months after bioprosthetic valve replacement to prevent thromboembolic events. However, data regarding whether direct oral anticoagulants can be an alternative to warfarin in such patients are limited. The purpose of this study is to compare the efficacy and safety of edoxaban versus warfarin within 3 months after bioprosthetic valve replacement. METHODS: The ENBALV trial is an investigator-initiated, phase 3, randomized, open-label, multicenter study. It involves patients aged 18 to 85 years undergoing bioprosthetic valve replacement at the aortic and/or mitral position. They are randomized 1:1 to receive either edoxaban or warfarin. Administration of edoxaban or warfarin is to be continued for 12 weeks after surgery. The primary outcome is the occurrence rate of stroke or systemic embolism at 12 weeks after surgery. The net clinical outcome is a composite of stroke, systemic embolism, or major bleeding, which is included in the secondary outcomes. CONCLUSION: The ENBALV trial demonstrates the efficacy and safety of edoxaban compared with warfarin in patients early after bioprosthetic valve replacement, including patients with sinus rhythm, which will bring a significant benefit to patients in clinical practice. TRIAL REGISTRATION: Japan Registry of Clinical Trials (jRCT) 2051210209. 30 Mar 2022 https://jrct.niph.go.jp/latest-detail/jRCT2051210209 .

5.
Artif Organs ; 48(9): 977-987, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38651352

RESUMO

BACKGROUND: In vitro assessment is mandatory for artificial heart valve development. This study aims to investigate the effects of pulse duplicator features on valve responsiveness, conduct a sensitivity analysis across valve prosthesis types, and contribute on the development of versatile pulse duplicator systems able to perform reliable prosthetic aortic valve assessment under physiologic hemodynamic conditions. METHODS: A reference pulse duplicator was established based on literature. Further optimization process led to new designs that underwent a parametric study, also involving different aortic valve prostheses. These designs were evaluated on criteria such as mean pressure differential and pulse pressure (assessed from high-fidelity pressure measurements), valve opening and closing behavior, flow, and regurgitation. Finally, the resulting optimized setup was tested under five different hemodynamic settings simulating a range of physiologic and pathologic conditions. RESULTS: The results show that both, pulse duplicator design and valve type significantly influence aortic and ventricular pressure, flow, and valve kinematic response. The optimal design comprised key features such as a compliance chamber and restrictor for diastolic pressure maintenance and narrow pulse pressure. Additionally, an atrial reservoir was included to prevent atrial-aortic interference, and a bioprosthetic valve was used in mitral position to avoid delayed valve closing effects. CONCLUSION: This study showed that individual pulse duplicator features can have a significant effect on valve's responsiveness. The optimized versatile pulse duplicator replicated physiologic and pathologic aortic valve hemodynamic conditions, serving as a reliable characterization tool for assessing and optimizing aortic valve performance.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Hemodinâmica , Desenho de Prótese , Humanos , Valva Aórtica/cirurgia , Modelos Cardiovasculares , Bioprótese
6.
Echocardiography ; 41(5): e15835, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38784978

RESUMO

PURPOSE: There is currently limited information on the utility of transthoracic echocardiography (TTE)-derived Doppler parameters for assessing bioprosthetic tricuspid valve (BTV) dysfunction. Our study aimed to establish the precision and appropriate reference ranges for routinely collected transthoracic Doppler parameters in the assessment of BTV dysfunction. METHODS: We retrospectively evaluated 100 BTV patients who underwent TTE. Based on redo surgical confirmation or more than 2 repeat TTE or transesophageal echocardiography (TEE) examinations, patients were allocated to normal (n = 61), regurgitant (n = 24), or stenotic (n = 15) BTV group. Univariate and multivariate binary logistic regression were performed to identify TTE Doppler parameters that detected BTV dysfunction. RESULTS: The VTI ratio (VTITV/VTILVOT) was the most accurate Doppler parameter for detecting BTV dysfunction, with a ratio of >2.8 showing 84.6% sensitivity and 90.2% specificity. VTI ratio > 3.2, mean gradient (MGTV) > 6.2 mmHg and pressure half-time > 218 ms detected significant BTV stenosis, with sensitivities of 100%, 93.3% and 93.3% and specificities of 82.4%, 75.3% and 87.1%, respectively. After multivariate analysis, the VTI ratio > 2.8 (OR = 9.00, 95% CI = 2.13-41.61, p = .003) and MGTV > 5.1 mmHg (OR = 6.50, 95% CI = 1.69-27.78, p = .008) were the independent associations of BTV dysfunction. With these cutoff values, 75.0%-92.2% of normal and 62.5%-96.0% of dysfunctional BTV were identified. CONCLUSIONS: Doppler parameters from TTE can accurately identify BTV dysfunction, particularly with VTI ratio > 2.8 and MGTV > 5.1 mmHg, to assess the need for additional testing with TEE.


Assuntos
Bioprótese , Ecocardiografia Doppler , Próteses Valvulares Cardíacas , Sensibilidade e Especificidade , Valva Tricúspide , Humanos , Feminino , Masculino , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Pessoa de Meia-Idade , Ecocardiografia Doppler/métodos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Idoso , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem
7.
Artigo em Inglês | MEDLINE | ID: mdl-39097488

RESUMO

Galactose-alpha-1,3-galactose (alpha-gal) is a carbohydrate expressed by all mammals except for humans and certain old-world primates. It can be found in a plethora of products derived from mammals, including milk, organs, skeletal muscle and gelatin, in addition to products prepared with mammalian cells or constituents. In the late 2000s, an association between tick bites and the development of immunoglobulin E antibodies to the alpha-gal carbohydrate was discovered. The term "alpha-gal syndrome" (AGS) was then coined to describe allergic reactions to mammalian meat or other alpha-gal-containing products derived from mammals. Symptoms are often delayed several hours from consumption and can be urticarial and/or gastrointestinal. Medications and bioprosthetic inserts derived from mammals were also noted to cause allergic reactions in affected patients. Cardiac surgery, in particular, is considered high risk, given that unfractionated heparin has a bovine or porcine origin and is administered in large doses for cardiopulmonary bypass. Bioprosthetic valves have similar origins and risks. Awareness of AGS in cardiac surgery patients can lead to decreased risk preoperatively and inform management perioperatively and postoperatively. In this narrative review, we have reviewed the published literature relevant to AGS in patients undergoing cardiac surgery and shared our treatment approach.

8.
J Formos Med Assoc ; 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38480086

RESUMO

OBJECTIVE: The use of RDV in SAVR is associated with risk of conduction abnormality requiring PPM implantation, when compared to conventional bioprosthetic valves. We aimed to evaluate the outcome after selective placement of annular compression sutures during surgical aortic valve replacement (SAVR) using Intuity rapid deployment valve (RDV). METHODS: This is a retrospective study of prospectively enrolled patients receiving SAVR using Intuity RDV. Selective placement of commissural compression suture was assessed for all patients based on their annular morphology. Outcomes including operative mortality, rate of pacemaker rate, paravalvular leak and change in trans-valvular pressure gradient were analyzed. RESULTS: 56 consecutive patients underwent SAVR with the INTUITY RDV at our institution from January 2020 to November 2021. The Mean age of our cohort was 69.9 ± 10.6 years with a EuroSCORE II of 3.4 ± 2.4%. 28.6% (16/56) of patients had notable conduction abnormalities pre-operatively, which included atrial fibrillation and left/right bundle branch block. Compression sutures were selectively applied in 19/56 (33.9%) patients. Of which, 13 were bicuspid aortic valve. Post-operatively, we observed no conduction abnormality requiring PPM implantation. In addition, only 3 of the 56 (5.4%) had any degree of paravalvular leak on post-operative echocardiography (all ≤ mild). The mean reduction in trans-valvular gradient was 29.9 mmHg and the mean pressure gradient at 1 month and 1 year follow-up were 9.3 ± 3.6 mmHg and 10.2 ± 4.1 mmHg, respectively. CONCLUSIONS: Selective placement of compression suture helps to avoid unnecessary oversizing, which may reduce the risk of paravalvular leak and post-operative PPM implantation.

9.
Rev Cardiovasc Med ; 24(9): 253, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39076400

RESUMO

Background: The choice between bioprosthetic and mechanical valves for aortic valve replacement (AVR) and mitral valve replacement (MVR) among patients aged 50-70 years is controversial. We compared the long-term outcomes of patients using bioprosthetic or mechanical valves to provide clinical evidence for valve selection. Methods: From 2002 to 2007, patients aged 50-70 years who underwent isolated AVR or MVR at the Fuwai Hospital were enrolled. After inverse probability-weighted (IPW) propensity balancing, we evaluated long-term mortality, stroke, and bleeding events between patients receiving mechanical and biological prostheses for MVR or AVR. Results: A total of 1639 patients were included in the study, including 1181 patients undergoing MVR (median follow-up: 11.6 years) and 458 patients undergoing AVR (median follow-up: 11.4 years). After IPW adjustment, there was no significant difference in long-term mortality and stroke rate between patients using bioprosthetic and mechanical valves for MVR [mortality: log-rank p = 0.802; stroke: log-rank p = 0.983] and AVR [mortality: log-rank p = 0.815; stroke: log-rank p = 0.537]. Landmark analysis at 12.5 years yielded significantly lower mortality in the patients receiving mechanical valves compared with bioprosthetic valves in the MVR cohort (p = 0.028). Patients receiving mechanical aortic valves displayed an increased risk of bleeding compared with those who received bioprosthetic aortic valves [Hazard Ratio (95% Confidence interval): 2.51 (1.06-5.93) p = 0.036]. Conclusions: For patients aged 50-70, there was no significant difference in overall long-term mortality between mechanical and bioprosthetic valve recipients. Patients receiving mechanical valves for MVR displayed lower mortality after 12.5 years follow-up. For AVR, bioprosthetic valves were associated with a lower risk of bleeding.

10.
J Surg Res ; 287: 124-133, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36933543

RESUMO

INTRODUCTION: Prosthesis choice during aortic valve replacement (AVR) weighs lifelong anticoagulation with mechanical valves (M-AVR) against structural valve degeneration in bioprosthetic valves (B-AVR). METHODS: The Nationwide Readmissions Database was queried to identify patients who underwent isolated surgical AVR between January 1, 2016 and December 31, 2018, stratifying by prothesis type. Propensity score matching was used to compare risk-adjusted outcomes. Readmission at 1 y was estimated with Kaplan-Meier (KM) analysis. RESULTS: Patients (n = 109,744) who underwent AVR (90,574 B-AVR and 19,170 M-AVR) were included. B-AVR patients were older (median 68 versus 57 y; P < 0.001) and had more comorbidities (mean Elixhauser score: 11.8 versus 10.7; P < 0.001) compared to M-AVR patients. After matching (n = 36,951), there was no difference in age (58 versus 57 y; P = 0.6) and Elixhauser score (11.0 versus 10.8; P = 0.3). B-AVR patients had similar in-hospital mortality (2.3% versus 2.3%; P = 0.9) and cost (mean: $50,958 versus $51,200; P = 0.4) compared with M-AVR patients. However, B-AVR patients had shorter length of stay (8.3 versus 8.7 d; P < 0.001) and fewer readmissions at 30 d (10.3% versus 12.6%; P < 0.001) and 90 d (14.8% versus 17.8%; P < 0.001), and 1 y (P < 0.001, KM analysis). Patients undergoing B-AVR were less likely to be readmitted for bleeding or coagulopathy (5.7% versus 9.9%; P < 0.001) and effusions (9.1% versus 11.9%; P < 0.001). CONCLUSIONS: B-AVR patients had similar early outcomes compared to M-AVR patients, but lower rates of readmission. Bleeding, coagulopathy, and effusions are drivers of excess readmissions in M-AVR patients. Readmission reduction strategies targeting bleeding and improved anticoagulation management are warranted in the first year following AVR.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Humanos , Valva Aórtica/cirurgia , Readmissão do Paciente , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Anticoagulantes/uso terapêutico , Estudos Retrospectivos , Desenho de Prótese
11.
BMC Cardiovasc Disord ; 23(1): 616, 2023 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-38097932

RESUMO

BACKGROUND: Mitral valve stenosis can be a highly symptomatic condition with significant complications if left untreated. In such cases, mitral valve replacement with a bioprosthetic or mechanical valve may be a viable solution to prevent progressive disease. Current guidelines do not recommend continued anticoagulation beyond 6 months for patients who have undergone bioprosthetic valve replacement without a separate indication for anticoagulation. With this case discussion we aim to 1) Review the current indications for anticoagulation for bioprosthetic mitral valves in patients without atrial fibrillation and 2) Discuss the constellation of comorbidities that may affect the decision to begin anticoagulation therapy. CASE PRESENTATION: We present a case describing a 55-year-old male with end-stage renal disease, coronary artery disease with coronary artery bypass graft surgery, and bioprosthetic mitral valve replacement 2 years prior with rapid degeneration of the replaced valve and on warfarin without a clear indication for anticoagulation. The patient was admitted for symptomatic, severe mitral stenosis and consideration of transcatheter mitral valve-in-valve replacement. During hospital admission, warfarin was discontinued and replaced with prophylactic anticoagulation. However, 8 days after warfarin cessation an intraoperative transesophageal echocardiography revealed a newly developed large left atrial thrombus leading to cancellation of the planned operation. CONCLUSIONS: This patient developed a left atrial thrombus after discontinuing warfarin in the setting of rapidly deteriorating bioprosthetic valve stenosis and vascular comorbidities. The decision to discontinue warfarin was made in concordance with current guidelines, which do not indicate systemic anticoagulation post 3-6 months after bioprosthetic valve replacement without separate indication for anticoagulation. This case identifies the need to investigate rebound hypercoagulability and further risk stratify comorbidities which may independently increase the risk of clot formation in the setting of severe mitral valve stenosis.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Estenose da Valva Mitral , Trombose , Humanos , Masculino , Pessoa de Meia-Idade , Anticoagulantes/efeitos adversos , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/cirurgia , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/prevenção & controle , Varfarina/efeitos adversos
12.
BMC Cardiovasc Disord ; 23(1): 324, 2023 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-37365533

RESUMO

BACKGROUND: Coronary embolism is a relatively rare but important non-atherosclerotic cause of acute coronary syndrome, mainly caused by atrial fibrillation and mechanical heart valve thrombosis due to subtherapeutic anticoagulation. There have been increasing reports of bioprosthetic valve thrombosis (BPVT), but thromboembolic events are rare and mainly affect the cerebrovascular system. Coronary embolism is an extremely rare complication of BPVT. CASE PRESENTATION: A 64-year-old male presented with non-ST-Elevation myocardial infarction (NSTEMI) to an Australian regional health service. Three years ago, he had undergone Bentall procedure with bioprosthetic aortic valve replacement for severe aortic regurgitation and significant aortic root dilatation. Diagnostic coronary angiography revealed embolic occlusion of first diagonal branch in the absence of underlying atherosclerosis. Prior to NSTEMI presentation, the patient was clinically asymptomatic apart from the progressive increase in transaortic mean pressure gradient on transthoracic echocardiography which was first detected seven months after surgical aortic valve replacement. Transoesophageal echocardiography showed restrictions of the aortic leaflet opening but no evidence of mass or vegetation. After eight weeks of warfarin therapy, the raised aortic valve gradient returned to normal. Lifelong warfarin was prescribed, and patient remained clinically well at 39-month follow-up. CONCLUSION: We experienced a case of coronary embolism in a patient with probable BPVT. Reversible bioprosthetic valve hemodynamic deterioration after anticoagulation strongly supports the diagnosis in the absence of histopathology. Early moderate-to-severe hemodynamic valve deterioration warrants further investigations, including cardiac computed tomography and sequential echocardiography, to investigate for probable BPVT and consideration of timely anticoagulation initiation to prevent thromboembolic events.


Assuntos
Bioprótese , Doença da Artéria Coronariana , Embolia , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Infarto do Miocárdio sem Supradesnível do Segmento ST , Tromboembolia , Trombose , Masculino , Humanos , Pessoa de Meia-Idade , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Varfarina/uso terapêutico , Implante de Prótese de Valva Cardíaca/efeitos adversos , Austrália , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/prevenção & controle , Próteses Valvulares Cardíacas/efeitos adversos , Tromboembolia/prevenção & controle , Anticoagulantes/uso terapêutico , Bioprótese/efeitos adversos
13.
J Thromb Thrombolysis ; 55(3): 474-489, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36528721

RESUMO

Since the beginning of the SARS-CoV-2 (COVID-19) pandemic, correlation of venous thromboembolism (VTE) and COVID-19 infection has been well established. Increased inflammatory response in the setting of COVID-19 infection is associated with VTE and hypercoagulability. Venous and arterial thrombotic events in COVID-19 infection have been well documented; however, few cases have been reported involving cardiac valve prostheses. In this review, we present a total of eight cases involving COVID-19-related prosthetic valve thrombosis (PVT), as identified in a systematic review. These eight cases describe valve position (mitral versus aortic) and prosthesis type (bioprosthetic versus mechanical), and all cases demonstrate incidents of PVT associated with simultaneous or recent COVID-19 infection. None of these eight cases display obvious non-adherence to anticoagulation; five of the cases occurred greater than three years after the most recent valve replacement. Our review offers insights into PVT in COVID-19 infected patients including an indication for increased monitoring in the peri-infectious period. We explore valve thrombosis as a mechanism for prosthetic valve failure. We describe potential differences in antithrombotic strategies that may offer added antithrombotic protection during COVID-19 infection. With the growing population of valve replacement patients and recurring COVID-19 infection surges, it is imperative to explore relationships between COVID-19 and PVT.


Assuntos
COVID-19 , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Trombose , Tromboembolia Venosa , Humanos , Fibrinolíticos , Tromboembolia Venosa/complicações , COVID-19/complicações , SARS-CoV-2 , Doenças das Valvas Cardíacas/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Trombose/complicações , Valva Aórtica
14.
J Korean Med Sci ; 38(48): e404, 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38084028

RESUMO

BACKGROUND: In the era of transcatheter aortic valve implantation, this study was conducted to investigate the current trend of aortic valve procedures in Korea and to evaluate the early and mid-term outcomes of isolated surgical aortic valve replacement (SAVR) using bioprosthetic valves in contemporary Korea. METHODS: Contemporary outcomes of isolated bioprosthetic SAVR in Korea were analyzed using the datasets on a multicenter basis. Patients who underwent isolated SAVR using bioprostheses from June 2015 to May 2019 were included, and those with concomitant cardiac procedures, SAVR with mechanical valve, or SAVR for infective endocarditis were excluded. A total of 456 patients from 4 large-volume centers were enrolled in this study. Median follow-up duration was 43.4 months. Early postoperative outcomes, mid-term clinical outcomes, and echocardiographic outcomes were evaluated. RESULTS: Mean age of the patients was 73.1 ± 7.3 years, and EuroSCORE II was 2.23 ± 2.09. The cardiopulmonary bypass time and aortic cross-clamp times were median 106 and 76 minutes, respectively. SAVR was performed with full median sternotomy (81.8%), right thoracotomy (14.7%), or partial sternotomy (3.5%). Operative mortality was 1.8%. The incidences of stroke and permanent pacemaker implantation were 1.1% and 1.1%, respectively. Paravalvular regurgitation ≥ mild was detected in 2.6% of the patients. Cumulative incidence of all-cause mortality at 5 years was 13.0%. Cumulative incidences of cardiovascular mortality and bioprosthetic valve dysfunction at 5 years were 7.6% and 6.8%, respectively. CONCLUSION: The most recent data for isolated SAVR using bioprostheses in Korea resulted in excellent early and mid-term outcomes in a multicenter study.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , República da Coreia/epidemiologia , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Conjuntos de Dados como Assunto , Estudos Multicêntricos como Assunto
15.
J Formos Med Assoc ; 122(1): 58-64, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36057527

RESUMO

BACKGROUND: Short-term oral anticoagulation (OAC) is recommended for patients after surgical bioprosthetic aortic valve replacement (bAVR); however, the potential benefits remain controversial. This study evaluated the effects of short-term OAC following bAVR. METHODS: From 2010 to 2017, total 450 patients who underwent bAVR were enrolled. The outcomes of patients who did (OAC group) and who did not receive OAC (without-OAC group) after bAVR were compared. Propensity-score matching (PSM) was used to adjust for potential confounders, and a 1:1 matched cohort was formed. The main outcomes were all-cause mortality and bioprosthetic valve dysfunction (BVD). RESULTS: A total of 175 (39%) patients received OAC after bAVR. The median follow-up period was 2.9 years, the median duration of OAC use was 4 months; 162 pairs of patients were identified after the PSM. There was no significant difference in the prevalence of 1-year embolism/ischemic stroke between the OAC and without-OAC group in PSM cohort (0.62% vs. 1.89% for embolism, p = 0.623; 0 vs. 1.23% for ischemic stroke, p = 0.499). The prevalence of 1-year intracranial hemorrhage (ICH) between OAC and without-OAC group was also comparable (0.62% vs. 0.62%, p = 1). The OAC group had a lower all-cause mortality (adjusted hazard ratio (aHR):0.488, 95% confidence interval (CI): 0.259-0.919). There was also a trend for reduced BVD in the OAC group (aHR: 0.661, 95% CI: 0.339-1.290). CONCLUSION: Our study demonstrated that short-term OAC use after bAVR was associated with lower all-cause mortality. The prevalence of 1-year embolism/ischemic stroke/ICH were comparable despite of OAC use.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , AVC Isquêmico , Humanos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Anticoagulantes , Resultado do Tratamento
16.
Rev Cardiovasc Med ; 23(8): 274, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39076635

RESUMO

Aortic interventions remain the most effective treatment for severe aortic stenosis. In the recent years, advances in bioprosthetics and newer data have reduced the cut-off age for the use of bioprosthetic valves in younger patients, but the debate on whether to favor mechanical valves in younger patients remains a constant, especially with the undesired effects and considerations of anticoagulation therapy with vitamin K antagonists in this age group. Other options like the Ross procedure are gaining traction, despite still being undervalued and necessitating expertise centers. Hemodynamic considerations and durability of these options are important to consider, especially in this age group. Regardless of the choice of the prosthesis, patient informed consent is paramount since the decision affects the lifetime management of their initial condition, and expectations given must remain realistic.

17.
Rev Cardiovasc Med ; 23(10): 343, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39077122

RESUMO

Prosthetic valves are increasingly encountered in clinical practice. A grasp of the intricacies of the assessment and management of prosthetic valves is thus a crucial skillset for the practicing cardiologist. Echocardiography is the imaging modality of choice for the anatomic and functional evaluation of prosthetic valve. This document reviews the general features of prosthetic valves, echocardiographic identification of normally functioning and dysfunctional prosthetic valves as well as echocardiographic diagnosis of specific prosthetic valvular abnormalities.

18.
Catheter Cardiovasc Interv ; 100(5): 841-849, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36040748

RESUMO

OBJECTIVES: The aim of this study was to investigate the degree of functional improvement of a transcatheter heart valve (THV) for valve-in-valve after bioprosthetic valve fracture (BVF) of three small surgical aortic valve bioprostheses (SAVBP) using high-pressure balloon aortic valvuloplasty (HP-BAV) under standardized ex-vivo-conditions. METHODS: A THV 26 mm (Evolut R) and SAVBP 21 mm (Perimount Magna Ease, Trifecta, and Epic supra [n = 4] were used. Mean pressure gradient (MPG), effective orifice area (EOA), geometric orifice area (GOA), minimal internal diameter (MID), and pinwheeling index (PWI) were analyzed before and after HP-BAV of the SAVBP using a noncompliant balloon. Fracturing of the SAVBP was done before implantation of the THV and the balloon pressures at the point of fracture were recorded. RESULTS: The Magna Ease and Epic fractured at balloon pressures of 18 and 8 atm, respectively. The Trifecta did not fracture up to a balloon pressure of 30 atm but was dilated. HP-BAV led to increased THV expansion as evident by straightened coaptation lines of the Evolut R 26 mm with reduced PWI, increased MID, and increased GOA in all 21 mm SAVBP. Evolut R showed significantly lower MPG and higher EOA as ViV in all prostheses after HP-BAV (p < 0.001). MPG and EOA of Evolut R differed regarding the SAVBP. Evolut R presented the lowest MPG and highest EOA in Magna Ease and the highest MPG and lowest EOA in Epic supra. CONCLUSIONS: The degree of function improvement of the same THV as ViV after HP-BAV depends on the surgical valve model. Functional improvement can also be achieved without valve fracture.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Hidrodinâmica , Desenho de Prótese , Resultado do Tratamento , Valvuloplastia com Balão/efeitos adversos
19.
Circ J ; 86(11): 1699-1707, 2022 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-35811134

RESUMO

BACKGROUND: Current guidelines equally recommend direct oral anticoagulants (DOACs) and warfarin for atrial fibrillation (AF) patients with a bioprosthetic valve (BPV); however, there are limited data comparing DOACs and warfarin in AF patients with an aortic BPV.Methods and Results: This post-hoc subgroup analysis of a multicenter, prospective, observational registry (BPV-AF Registry) aimed to compare DOACs and warfarin in AF patients with an aortic BPV. The primary outcome was a composite of stroke, systemic embolism, major bleeding, heart failure requiring hospitalization, all-cause death, or BPV reoperation. The analysis included 479 patients (warfarin group, n=258; DOAC group, n=221). Surgical aortic valve replacement was performed in 74.4% and 36.7% of patients in the warfarin and DOAC groups, respectively. During a mean follow up of 15.5 months, the primary outcome occurred in 45 (17.4%) and 32 (14.5%) patients in the warfarin and DOAC groups, respectively. No significant difference was found in the primary outcome between the 2 groups (adjusted hazard ratio: 0.88, 95% confidence interval: 0.51-1.50). No significant multiplicative interaction was observed between the anticoagulant effects and type of aortic valve procedure (P=0.577). CONCLUSIONS: Among AF patients with an aortic BPV, no significant difference was observed in the composite outcome of adverse clinical events between patients treated with warfarin and those treated with DOACs, suggesting that DOACs can be used as alternatives to warfarin in these patients.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Varfarina/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/complicações , Valva Aórtica/cirurgia , Estudos Prospectivos , Administração Oral , Anticoagulantes/efeitos adversos , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/induzido quimicamente , Resultado do Tratamento
20.
Echocardiography ; 39(6): 844-848, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35524711

RESUMO

Bioprosthetic valve thrombosis (BPVT) is a growing recognized entity, especially with the increasing use of the valve in vale procedures and the advent of new detection technologies (e.g., 4D CT and 4D echocardiography). The incidence of BPVT is higher in transcatheter valves than surgically implanted bioprosthetic valves. However, the best thromboprophylaxis regimen and optimal management strategy in the acute context remain unknown. This paper presents a case of early thrombosis following the percutaneous tricuspid valve in vale procedure that was successfully managed with thrombolysis.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Trombose , Tromboembolia Venosa , Anticoagulantes/uso terapêutico , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Desenho de Prótese , Falha de Prótese , Terapia Trombolítica , Trombose/diagnóstico por imagem , Trombose/tratamento farmacológico , Trombose/etiologia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Tromboembolia Venosa/complicações , Tromboembolia Venosa/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA