1.
NMR Biomed ; 37(4): e5091, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38196195

RESUMO

BACKGROUND: Despite the widespread use of cine MRI for evaluation of cardiac function, existing real-time methods do not easily enable quantification of ventricular function. Moreover, segmented cine MRI assumes periodicity of cardiac motion. We aim to develop a self-gated, cine MRI acquisition scheme with data-driven cluster-based binning of cardiac motion. METHODS: A Cartesian golden-step balanced steady-state free precession sequence with sorted k-space ordering was designed. Image data were acquired with breath-holding. Principal component analysis and k-means clustering were used for binning of cardiac phases. Cluster compactness in the time dimension was assessed using temporal variability, and dispersion in the spatial dimension was assessed using the Calinski-Harabasz index. The proposed and the reference electrocardiogram (ECG)-gated cine methods were compared using a four-point image quality score, SNR and CNR values, and Bland-Altman analyses of ventricular function. RESULTS: A total of 10 subjects with sinus rhythm and 8 subjects with arrhythmias underwent cardiac MRI at 3.0 T. The temporal variability was 45.6 ms (cluster) versus 24.6 ms (ECG-based) (p < 0.001), and the Calinski-Harabasz index was 59.1 ± 9.1 (cluster) versus 22.0 ± 7.1 (ECG based) (p < 0.001). In subjects with sinus rhythm, 100% of the end-systolic and end-diastolic images from both the cluster and reference approach received the highest image quality score of 4. Relative to the reference cine images, the cluster-based multiphase (cine) image quality consistently received a one-point lower score (p < 0.05), whereas the SNR and CNR values were not significantly different (p = 0.20). In cases with arrhythmias, 97.9% of the end-systolic and end-diastolic images from the cluster approach received an image quality score of 3 or more. The mean bias values for biventricular ejection fraction and volumes derived from the cluster approach versus reference cine were negligible. CONCLUSION: ECG-free cine cardiac MRI with data-driven clustering for binning of cardiac motion is feasible and enables quantification of cardiac function.


Assuntos
Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Função Ventricular , Análise por Conglomerados , Reprodutibilidade dos Testes
2.
J Magn Reson Imaging ; 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38436994

RESUMO

BACKGROUND: Balanced steady-state free precession (bSSFP) imaging is commonly used in cardiac cine MRI but prone to image artifacts. Ferumoxytol-enhanced (FE) gradient echo (GRE) has been proposed as an alternative. Utilizing the abundance of bSSFP images to develop a computationally efficient network that is applicable to FE GRE cine would benefit future network development. PURPOSE: To develop a variable-splitting spatiotemporal network (VSNet) for image reconstruction, trained on bSSFP cine images and applicable to FE GRE cine images. STUDY TYPE: Retrospective and prospective. SUBJECTS: 41 patients (26 female, 53 ± 19 y/o) for network training, 31 patients (19 female, 49 ± 17 y/o) and 5 healthy subjects (5 female, 30 ± 7 y/o) for testing. FIELD STRENGTH/SEQUENCE: 1.5T and 3T, bSSFP and GRE. ASSESSMENT: VSNet was compared to VSNet with total variation loss, compressed sensing and low rank methods for 14× accelerated data. The GRAPPA×2/×3 images served as the reference. Peak signal-to-noise-ratio (PSNR), structural similarity index (SSIM), left ventricular (LV) and right ventricular (RV) end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) were measured. Qualitative image ranking and scoring were independently performed by three readers. Latent scores were calculated based on scores of each method relative to the reference. STATISTICS: Linear mixed-effects regression, Tukey method, Fleiss' Kappa, Bland-Altman analysis, and Bayesian categorical cumulative probit model. A P-value <0.05 was considered statistically significant. RESULTS: VSNet achieved significantly higher PSNR (32.7 ± 0.2), SSIM (0.880 ± 0.004), rank (2.14 ± 0.06), and latent scores (-1.72 ± 0.22) compared to other methods (rank >2.90, latent score < -2.63). Fleiss' Kappa was 0.52 for scoring and 0.61 for ranking. VSNet showed no significantly different LV and RV ESV (P = 0.938) and EF (P = 0.143) measurements, but statistically significant different (2.62 mL) EDV measurements compared to the reference. CONCLUSION: VSNet produced the highest image quality and the most accurate functional measurements for FE GRE cine images among the tested 14× accelerated reconstruction methods. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 1.

3.
Eur Radiol ; 34(7): 4261-4272, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38114847

RESUMO

OBJECTIVES: To compare cardiac computed tomography (CCT) and cardiac magnetic resonance (CMR) for the quantitative assessment of the left ventricular (LV) trabeculated layer in patients with suspected noncompaction cardiomyopathy (NCCM). MATERIALS AND METHODS: Subjects with LV excessive trabeculation who underwent both CMR and CCT imaging as part of the prospective international multicenter NONCOMPACT clinical study were included. For each subject, short-axis CCT and CMR slices were matched. Four quantitative metrics were estimated: 1D noncompacted-to-compacted ratio (NCC), trabecular-to-myocardial area ratio (TMA), trabecular-to-endocardial cavity area ratio (TCA), and trabecular-to-myocardial volume ratio (TMV). In 20 subjects, end-diastolic and mid-diastolic CCT images were compared for the quantification of the trabeculated layer. Relationships between the metrics were investigated using linear regression models and Bland-Altman analyses. RESULTS: Forty-eight subjects (49.9 ± 12.8 years; 28 female) were included in this study. NCC was moderately correlated (r = 0.62), TMA and TMV were strongly correlated (r = 0.78 and 0.78), and TCA had excellent correlation (r = 0.92) between CMR and CCT, with an underestimation bias from CCT of 0.3 units, and 5.1, 4.8, and 5.4 percent-points for the 4 metrics, respectively. TMA, TCA, and TMV had excellent correlations (r = 0.93, 0.96, 0.94) and low biases (- 3.8, 0.8, - 3.8 percent-points) between the end-diastolic and mid-diastolic CCT images. CONCLUSIONS: TMA, TCA, and TMV metrics of the LV trabeculated layer in patients with suspected NCCM demonstrated high concordance between CCT and CMR images. TMA and TCA were highly reproducible and demonstrated minimal differences between mid-diastolic and end-diastolic CCT images. CLINICAL RELEVANCE STATEMENT: The results indicate similarity of CCT to CMR for quantifying the LV trabeculated layer, and the small differences in quantification between end-diastole and mid-diastole demonstrate the potential for quantifying the LV trabeculated layer from clinically performed coronary CT angiograms. KEY POINTS: • Data on cardiac CT for quantifying the left ventricular trabeculated layer are limited. • Cardiac CT yielded highly reproducible metrics of the left ventricular trabeculated layer that correlated well with metrics defined by cardiac MR. • Cardiac CT appears to be equivalent to cardiac MR for the quantification of the left ventricular trabeculated layer.


Assuntos
Ventrículos do Coração , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Ventrículos do Coração/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Adulto
4.
AJR Am J Roentgenol ; 222(5): e2330272, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38323784

RESUMO

BACKGROUND. Cine cardiac MRI sequences require repeated breath-holds, which can be difficult for patients with ischemic heart disease (IHD). OBJECTIVE. The purpose of the study was to compare a free-breathing accelerated cine sequence using deep learning (DL) reconstruction and a standard breath-hold cine sequence in terms of image quality and left ventricular (LV) measurements in patients with IHD undergoing cardiac MRI. METHODS. This prospective study included patients undergoing 1.5- or 3-T cardiac MRI for evaluation of IHD between March 15, 2023, and June 21, 2023. Examinations included an investigational free-breathing cine short-axis sequence with DL reconstruction (hereafter, cine-DL sequence). Two radiologists (reader 1 [R1] and reader 2 [R2]), in blinded fashion, independently assessed left ventricular ejection fraction (LVEF), left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), and subjective image quality for the cine-DL sequence and a standard breath-hold balanced SSFP sequence; R1 assessed artifacts. RESULTS. The analysis included 26 patients (mean age, 64.3 ± 11.7 [SD] years; 14 men, 12 women). Acquisition was shorter for the cine-DL sequence than the standard sequence (mean ± SD, 0.6 ± 0.1 vs 2.4 ± 0.6 minutes; p < .001). The cine-DL sequence, in comparison with the standard sequence, showed no significant difference for LVEF for R1 (mean ± SD, 51.7% ± 14.3% vs 51.3% ± 14.7%; p = .56) or R2 (53.4% ± 14.9% vs 52.8% ± 14.6%; p = .53); significantly greater LVEDV for R2 (mean ± SD, 171.9 ± 51.9 vs 160.6 ± 49.4 mL; p = .01) but not R1 (171.8 ± 53.7 vs 165.5 ± 52.4 mL; p = .16); and no significant difference in LVESV for R1 (mean ± SD, 88.1 ± 49.3 vs 86.0 ± 50.5 mL; p = .45) or R2 (85.2 ± 48.1 vs 81.3 ± 48.2 mL; p = .10). The mean bias between the cine-DL and standard sequences by LV measurement was as follows: LVEF, 0.4% for R1 and 0.7% for R2; LVEDV, 6.3 mL for R1 and 11.3 mL for R2; and LVESV, 2.1 mL for R1 and 3.9 mL for R2. Subjective image quality was better for cine-DL sequence than the standard sequence for R1 (mean ± SD, 2.3 ± 0.5 vs 1.9 ± 0.8; p = .02) and R2 (2.2 ± 0.4 vs 1.9 ± 0.7; p = .02). R1 reported no significant difference between the cine-DL and standard sequences for off-resonance artifacts (3.8% vs 23.1% examinations; p = .10) and parallel imaging artifacts (3.8% vs 19.2%; p = .19); blurring artifacts were more frequent for the cine-DL sequence than the standard sequence (42.3% vs 7.7% examinations; p = .008). CONCLUSION. A free-breathing cine-DL sequence, in comparison with a standard breath-hold cine sequence, showed very small bias for LVEF measurements and better subjective quality. The cine-DL sequence yielded greater LV volumes than the standard sequence. CLINICAL IMPACT. A free-breathing cine-DL sequence may yield reliable LVEF measurements in patients with IHD unable to repeatedly breath-hold. TRIAL REGISTRATION. ClinicalTrials.gov NCT05105984.


Assuntos
Suspensão da Respiração , Aprendizado Profundo , Imagem Cinética por Ressonância Magnética , Isquemia Miocárdica , Humanos , Masculino , Feminino , Estudos Prospectivos , Isquemia Miocárdica/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Idoso , Interpretação de Imagem Assistida por Computador/métodos
5.
Magn Reson Med ; 90(1): 222-230, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36864561

RESUMO

PURPOSE: To investigate the feasibility of combining simultaneous multislice (SMS) and region-optimized virtual coils (ROVir) for single breath-hold CINE imaging. METHOD: ROVir is a recent virtual coil approach that allows reduced-field of view (FOV) imaging by localizing the signal from a region-of-interest (ROI) and/or suppressing the signal from unwanted spatial regions. In this work, ROVir is used for reduced-FOV SMS bSSFP CINE imaging, which enables whole heart CINE with a single breath-hold acquisition. RESULTS: Reduced-FOV CINE with either SMS-only or ROVir-only resulted in significant aliasing, with severely reduced image quality when compared to the full FOV reference CINE, while the visual appearance of aliasing was substantially reduced with the proposed SMS+ROVir. The end diastolic volume, end systolic volume, and ejection fraction obtained using the proposed approach were similar to the clinical reference (correlations of 0.92, 0.94, and 0.88, respectively with p < 0 . 05 $$ p<0.05 $$ in each case, and biases of 0.1, 1.6 mL, and - 0 . 6 % $$ -0.6\% $$ , respectively). No statistically significant differences for these parameters were found with a Wilcoxon rank test (p = 0.96, 0.20, and 0.40, respectively). CONCLUSION: We demonstrated that reduced-FOV CINE imaging with SMS+ROVir enables single breath-hold whole-heart imaging without compromising visual image quality or quantitative cardiac function parameters.


Assuntos
Suspensão da Respiração , Imagem Cinética por Ressonância Magnética , Imagem Cinética por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Interpretação de Imagem Assistida por Computador/métodos
6.
J Magn Reson Imaging ; 58(3): 807-814, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36533630

RESUMO

BACKGROUND: Although radiomics features of the left ventricular wall have been used to assess cardiac diseases, radiomics features of the cardiac blood pool have been relatively ignored. PURPOSE: To test the hypothesis that cine MRI-derived radiomics features of the cardiac blood pool are associated with cardiac function and motion. STUDY TYPE: Retrospective. POPULATION: A total of 26 healthy volunteers (51.2 ± 15.6 years; 17 males). FIELD STRENGTH/SEQUENCE: A 1.5 T/balanced steady-state free precession (bSSFP). ASSESSMENT: The radiomics features (107 features in seven classes) of the blood pool of the left/right ventricle/atrium (LV/RV/LA/RA) were extracted on four-chamber cine images (25 phases). Conventional cardiac function parameters (volumes, ejection fraction [EF] and longitudinal strain) were assessed in each cardiac chamber. Intraobserver- and interobserver agreements of radiomics features of all chambers acquired at all phases were assessed, as well as scan-rescan agreement in a subset of 13 volunteers. STATISTICAL TESTS: Pearson correlation coefficients (r) were used to assess the associations between peak values of radiomics features and end-diastolic (or maximal) volume, end-systolic (or minimal) volume, EF, and longitudinal strain of corresponding chambers. Good intraobserver, interobserver, and scan-rescan agreements for radiomics features acquired were defined as intraclass correlation coefficient (ICC) > 0.7 or coefficient of variation (CoV) < 20%. RESULTS: Most radiomics features of the blood pool varied periodically throughout the cardiac cycle. Peak values of chamber-specific blood pool radiomics features were correlated with traditional cardiac function and motion indices of corresponding chambers (r: 0.4-0.87). Ninety-three (87%), 86 (80%), and 73 (68%) radiomics features demonstrated good intraobserver, interobserver, and scan-rescan reproducibility, respectively. CONCLUSION: Cine MRI-derived radiomics features within LV/RV/LA/RA are associated with traditional cardiac function and motion indices of corresponding chambers and may have the potential to become novel quantitative imaging biomarkers in cardiovascular medicine. EVIDENCE LEVEL: 3. TECHNICAL EFFICACY: 1.


Assuntos
Ventrículos do Coração , Imagem Cinética por Ressonância Magnética , Masculino , Humanos , Estudos Retrospectivos , Imagem Cinética por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Ventrículos do Coração/diagnóstico por imagem , Átrios do Coração , Volume Sistólico , Função Ventricular Esquerda
7.
BMC Cardiovasc Disord ; 23(1): 473, 2023 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-37735355

RESUMO

PURPOSE: Highly accelerated compressed sensing cine has allowed for quantification of ventricular function in a single breath hold. However, compared to segmented breath hold techniques, there may be underestimation or overestimation of LV volumes. Furthermore, a heterogeneous sample of techniques have been used in volunteers and patients for pre-clinical and clinical use. This can complicate individual comparisons where small, but statistically significant differences exist in left ventricular morphological and/or functional parameters. This meta-analysis aims to provide a comparison of conventional cine versus compressed sensing based reconstruction techniques in patients and volunteers. METHODS: Two investigators performed systematic searches for eligible studies using PubMed/MEDLINE and Web of Science to identify studies published 1/1/2010-3/1/2021. Ultimately, 15 studies were included for comparison between compressed sensing cine and conventional imaging. RESULTS: Compared to conventional cine, there were small, statistically significant overestimation of LV mass, underestimation of stroke volume and LV end diastolic volume (mean difference 2.65 g [CL 0.57-4.73], 2.52 mL [CL 0.73-4.31], and 2.39 mL [CL 0.07-4.70], respectively). Attenuated differences persisted across studies using prospective gating (underestimated stroke volume) and non-prospective gating (underestimation of stroke volume, overestimation of mass). There were no significant differences in LV volumes or LV mass with high or low acceleration subgroups in reference to conventional cine except slight underestimation of ejection fraction among high acceleration studies. Reduction in breath hold acquisition time ranged from 33 to 64%, while reduction in total scan duration ranged from 43 to 97%. CONCLUSION: LV volume and mass assessment using compressed sensing CMR is accurate compared to conventional parallel imaging cine.


Assuntos
Coração , Imageamento por Ressonância Magnética , Humanos , Ventrículos do Coração , Suspensão da Respiração , Espectroscopia de Ressonância Magnética
8.
MAGMA ; 36(3): 355-373, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37171689

RESUMO

OBJECT: Lower-field MR is reemerging as a viable, potentially cost-effective alternative to high-field MR, thanks to advances in hardware, sequence design, and reconstruction over the past decades. Evaluation of lower field strengths, however, is limited by the availability of lower-field systems on the market and their considerable procurement costs. In this work, we demonstrate a low-cost, temporary alternative to purchasing a dedicated lower-field MR system. MATERIALS AND METHODS: By ramping down an existing clinical 3 T MRI system to 0.75 T, proton signals can be acquired using repurposed 13C transmit/receive hardware and the multi-nuclei spectrometer interface. We describe the ramp-down procedure and necessary software and hardware changes to the system. RESULTS: Apart from presenting system characterization results, we show in vivo examples of cardiac cine imaging, abdominal two- and three-point Dixon-type water/fat separation, water/fat-separated MR Fingerprinting, and point-resolved spectroscopy. In addition, the ramp-down approach allows unique comparisons of, e.g., gradient fidelity of the same MR system operated at different field strengths using the same receive chain, gradient coils, and amplifiers. DISCUSSION: Ramping down an existing MR system may be seen as a viable alternative for lower-field MR research in groups that already own multi-nuclei hardware and can also serve as a testing platform for custom-made multi-nuclei transmit/receive coils.


Assuntos
Imageamento por Ressonância Magnética , Software , Imageamento por Ressonância Magnética/métodos , Prótons
9.
Skeletal Radiol ; 52(7): 1349-1358, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36609720

RESUMO

OBJECTIVE: To confirm the relationship between lumbar spinal stenosis (LSS) and cauda equina movement during the Valsalva maneuver. MATERIALS AND METHODS: Two radiologists at our institution independently evaluated cauda equina movement on pelvic cine MRI, which was performed for urethrorrhea after prostatectomy or pelvic prolapse in 105 patients (99 males; mean age: 69.0 [range: 50-78] years), who also underwent abdominopelvic CT within 2 years before or after the MRI. The qualitative assessment of the cine MRI involved subjective determination of the cauda equina movement type (non-movement, flutter, and inchworm-manner). The severity of LSS on abdominopelvic CT was quantified using our LSS scoring system and performed between L1/2 and L5/S1. We calculated the average LSS scores of two analysts and extracted the worst scores among all levels. RESULTS: Cauda equina movement was observed in 15 patients (14%), inchworm-manner in 10 patients, and flutter in five patients. Participants with cauda equina movement demonstrated significantly higher LSS scores than those without movement (P < 0.001, Wilcoxon's rank-sum test). A significant difference was observed in the worst LSS scores between participants without movement and those with inchworm-manner movement (P < 0.001, Bonferroni's corrected). There were no significant differences between participants without movement and those with flutter movement (P = 0.3156) and between participants with flutter movement and those with inchworm-manner movement (P = 0.4843). CONCLUSION: Cauda equina movement in cine MRI during the Valsalva maneuver is occasionally observed in patients with severe LSS, and may be associated with pathogenesis of redundant nerve roots.


Assuntos
Cauda Equina , Estenose Espinal , Masculino , Humanos , Idoso , Cauda Equina/diagnóstico por imagem , Cauda Equina/patologia , Cauda Equina/cirurgia , Estenose Espinal/complicações , Manobra de Valsalva , Vértebras Lombares/patologia , Imageamento por Ressonância Magnética
10.
J Appl Clin Med Phys ; 24(6): e13930, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37073428

RESUMO

Treatment tolerability is a significant limitation to pancreatic cancer treatment with radiotherapy due to proximity to highly radiosensitive organs and respiratory motion necessitating expanded target margins. Further, pancreatic tumors are difficult to visualize on conventional radiotherapy systems. Surrogates are often used to locate the tumor but are often inconsistent and do not provide strong positional relations throughout the respiratory cycle. This work utilizes a retrospective dataset of 45 pancreatic cancer patients treated on an MR-Linac system with cine MRI acquired for real-time target tracking. We investigated intra-fraction motion of tumors and two abdominal surrogates, leading to prediction models between the tumor and surrogate. Patient specific motion evaluation and prediction models were generated from 225 cine MRI series acquired during treatment. Tumor contours were used to evaluate the pancreatic tumor motion. Linear regression and principal component analysis (PCA) based models were used to predict tumor position from the anterior-posterior (AP) motion of the abdominal surface, the superior-inferior (SI) motion of the diaphragm, or a combination. Models were evaluated using mean squared error (MSE) and mean absolute error (MAE). Contour analysis showed the average pancreatic tumor motion range was 7.4 ± 2.7 mm and 14.9 ± 5.8 mm in the AP and SI directions, respectively. The PCA model had MSE of 1.4 mm2 and 0.6 mm2 , for the SI and AP directions, respectively, with both surrogates as inputs for the models. When only the abdomen surrogate was used, MSE was 1.3 mm2 and 0.4 mm2 in the SI and AP directions, while it was 0.4 mm2 and 1.3 mm2 when only the diaphragm surrogate was used. We evaluated intra-fraction pancreatic tumor motion and demonstrated prediction models between the tumor and surrogate. The models calculated the pancreatic tumor position from diaphragm, abdominal, or both contours within standard pancreatic cancer target margin, and the process could be applied to other disease sites in the abdominothoracic cavity.


Assuntos
Imagem Cinética por Ressonância Magnética , Neoplasias Pancreáticas , Humanos , Estudos Retrospectivos , Respiração , Movimento (Física) , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/patologia , Movimento , Neoplasias Pancreáticas
11.
J Appl Clin Med Phys ; 24(10): e14078, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37335543

RESUMO

PURPOSE: To investigate the dosimetry effects of different gating strategies in cine magnetic resonance imaging (MRI)-guided breath-hold pancreatic cancer radiotherapy. METHODS: Two cine MRI-based gating strategies were investigated: a tumor contour-based gating strategy at a gating threshold of 0-5% and a tumor displacement-based gating strategy at a gating threshold of 3-5 mm. The cine MRI videos were obtained from 17 pancreatic cancer patients who received MRI-guided radiation therapy. We calculated the tumor displacement in each cine MR frame that satisfied the gating threshold and obtained the proportion of frames with different displacements. We generated IMRT and VMAT plans using a 33 Gy prescription, and motion plans were generated by adding up all isocenter-shift plans corresponding to different tumor displacements. The dose parameters of GTV, PTV, and organs at risk (OAR) were compared between the original and motion plans. RESULTS: In both gating strategies, the difference was significant in PTV coverage but not in GTV coverage between the original and motion plans. OAR dose parameters deteriorate with increasing gating threshold. The beam duty cycle increased from 19.5±14.3% (median 18.0%) to 60.8±15.6% (61.1%) for gating thresholds from 0% to 5% in tumor contour-based gating and from 51.7±11.5% (49.7%) to 67.3±12.4% (67.1%) for gating thresholds from 3 to 5 mm in tumor displacement-based gating. CONCLUSION: In tumor contour-based gating strategy, the dose delivery accuracy deteriorates while the dose delivery efficiency improves with increasing gating thresholds. To ensure treatment efficiency, the gating threshold might be no less than 3%. A threshold up to 5% may be acceptable in terms of the GTV coverage. The displacement-based gating strategy may serve as a potential alternative to the tumor contour based gating strategy, in which the gating threshold of approximately 4 mm might be a good choice for reasonably balancing the dose delivery accuracy and efficiency.


Assuntos
Neoplasias Pancreáticas , Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Humanos , Neoplasias Pancreáticas/radioterapia , Suspensão da Respiração , Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Radioterapia Guiada por Imagem/métodos , Neoplasias Pancreáticas
12.
Sensors (Basel) ; 23(14)2023 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-37514888

RESUMO

Cardiac function indices must be calculated using tracing from short-axis images in cine-MRI. A 3D-CNN (convolutional neural network) that adds time series information to images can estimate cardiac function indices without tracing using images with known values and cardiac cycles as the input. Since the short-axis image depicts the left and right ventricles, it is unclear which motion feature is captured. This study aims to estimate the indices by learning the short-axis images and the known left and right ventricular ejection fractions and to confirm the accuracy and whether each index is captured as a feature. A total of 100 patients with publicly available short-axis cine images were used. The dataset was divided into training:test = 8:2, and a regression model was built by training with the 3D-ResNet50. Accuracy was assessed using a five-fold cross-validation. The correlation coefficient, MAE (mean absolute error), and RMSE (root mean squared error) were determined as indices of accuracy evaluation. The mean correlation coefficient of the left ventricular ejection fraction was 0.80, MAE was 9.41, and RMSE was 12.26. The mean correlation coefficient of the right ventricular ejection fraction was 0.56, MAE was 11.35, and RMSE was 14.95. The correlation coefficient was considerably higher for the left ventricular ejection fraction. Regression modeling using the 3D-CNN indicated that the left ventricular ejection fraction was estimated more accurately, and left ventricular systolic function was captured as a feature.


Assuntos
Função Ventricular Esquerda , Função Ventricular Direita , Humanos , Volume Sistólico , Imagem Cinética por Ressonância Magnética/métodos , Coração
13.
Neuroimage ; 258: 119361, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35688317

RESUMO

Quantification of the effect of breathing on the cerebral circulation provides a better mechanistic understanding of the brain's circulatory system and is important in the early diagnosis of certain neurological diseases. However, conventional cine phase-contrast (CINE-PC) MRI cannot be used in this field of study because it only provides an average cardiac cycle flow curve reconstructed from multiple cardiac cycles. Unlike CINE-PC, phase-contrast echo-planar imaging (EPI-PC) can be used to quantify the blood flow rate in "real-time" and thus assess the effect of breathing on blood flow. Here, we first used post-processing software (developed in-house) to determine the feasibility of quantifying cerebral arterial blood flow with EPI-PC (relative to CINE-PC) in 16 participants. In a second step, we developed a new time-domain method for quantifying the intensity and the phase shift of the effects of breathing on the mean flow rate, stroke volume, cardiac period and amplitude of cerebral blood flow (in 10 participants). Our results showed that EPI-PC can quantify cerebral arterial blood flow rate with much the same degree of accuracy as CINE-PC but is more strongly influenced by differences in magnetic susceptibility. We found that breathing affected the mean flow rate, stroke volume and cardiac period of cerebral arterial blood flow.


Assuntos
Imagem Cinética por Ressonância Magnética , Imageamento por Ressonância Magnética , Velocidade do Fluxo Sanguíneo/fisiologia , Artérias Cerebrais/diagnóstico por imagem , Imagem Ecoplanar/métodos , Humanos , Imagem Cinética por Ressonância Magnética/métodos
14.
Neurourol Urodyn ; 41(2): 616-625, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34962308

RESUMO

AIM: Post-prostatectomy urinary incontinence (PPI) is the greatest concern for urologists after radical prostatectomy (RP). It is thought that PPI is composed of multiple factors including static and dynamic components. The purpose of this study is to show visually levator ani muscle (LAM) contraction during pelvic floor muscle contraction and to evaluate the dynamic differences in its contraction between men with and without PPI. METHODS: This study was a case-control study of the urinary continent or incontinent men. It investigated whether LAM contraction was involved in urinary leakage based on examination of LAM contraction by cine magnetic resonance imaging. RESULTS: The LAM contracted from the coccyx to the pubis in the same manner before and after surgery. The degree of contraction of the LAM in post-prostatectomy groups was smaller than that in the healthy adult group. The contraction distances of each part of the pelvic floor were decreased by 50%-70% in the incontinence group compared to those in the continence group. The bladder neck moved 2.5-fold further in the continence group and the direction of movement was more vertical than in the incontinence group. Urethral compression was attenuated by about 40% in the incontinence group compared to that in the continence group. CONCLUSIONS: RP can cause damage to the LAM. LAM contraction is reduced after RP compared with that in healthy adult men. In men with PPI, the reduced muscle contraction might not compress the urethra sufficiently when abdominal pressure is raised. Pelvic floor muscle training might provide a meaningful method for the recovery of LAM contraction in patients with PPI.


Assuntos
Imagem Cinética por Ressonância Magnética , Incontinência Urinária , Adulto , Estudos de Casos e Controles , Humanos , Masculino , Contração Muscular , Diafragma da Pelve/diagnóstico por imagem , Prostatectomia/efeitos adversos , Prostatectomia/métodos , Incontinência Urinária/diagnóstico por imagem , Incontinência Urinária/etiologia
15.
Eur Arch Otorhinolaryngol ; 279(2): 595-607, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34241671

RESUMO

PURPOSE: The objective of this study is to systematically review the international literature for dynamic sleep magnetic resonance imaging (MRI) as a diagnostic tool in obstructive sleep apnea (OSA), to perform meta-analysis on the quantitative data from the review, and to discuss its implications in future research and potential clinical applications. STUDY DESIGN: A comprehensive review of the literature was performed, followed by a detailed analysis of the relevant data that has been published on the topic. METHODS: Clinical key, Uptodate, Ovid, Ebscohost, Pubmed/MEDLINE, Scopus, Dynamed, Web of Science and The Cochrane Library were systematically searched. Once the search was completed, dynamic sleep MRI data were analyzed. RESULTS: Nineteen articles reported on 410 OSA patients and 79 controls that underwent dynamic sleep MRI and were included in this review. For meta-analysis of dynamic sleep MRI data, eight articles presented relevant data on 160 OSA patients. Obstruction was reported as follows: retropalatal (RP) 98%, retroglossal (RG) 41% and hypopharyngeal (HP) in 5%. Lateral pharyngeal wall (LPW) collapse was found in 35/73 (48%) patients. The combinations of RP + RG were observed in 24% and RP + RG + LPW in 16%. If sedation was used, 98% of study participants fell asleep compared to 66% of unsedated participants. CONCLUSIONS: Dynamic sleep MRI has demonstrated that nearly all patients have retropalatal obstruction, retroglossal obstruction is common and hypopharyngeal obstruction is rare. Nearly all patients (98%) who are sedated are able to fall asleep during the MRI. There is significant heterogeneity in the literature and standardization is needed.


Assuntos
Apneia Obstrutiva do Sono , Humanos , Imageamento por Ressonância Magnética , Faringe , Sono , Apneia Obstrutiva do Sono/diagnóstico por imagem
16.
J Appl Clin Med Phys ; 23(7): e13650, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35615991

RESUMO

PURPOSE: Since 4D-MRI is inadequate to capture dynamic respiratory variations, real-time cinematographic (cine) MRI is actively used in MR-guided radiotherapy (MRgRT) for tumor motion evaluation, delineation, and tracking. However, most radiotherapy imaging platforms do not support the format of cine MRI from clinical MRI systems. This study developed an institutional solution of clinical cine MRI for tumor motion evaluation in radiotherapy applications. METHODS: Cine MRI manipulation software (called Cine Viewer) was developed within a commercial Treatment Planning System (TPS). It consists of (1) single/orthogonal viewers, (2) display controllers, (3) measurement grids/markers, and (4) manual contouring tools. RESULTS: The institutional solution of clinical cine MRI incorporated with radiotherapy application was assessed through case presentations (liver cancer). Cine Viewer loaded cine MRIs from 1.5T Philips Ingenia MRI, handling MRI DICOM format. The measurement grids and markers were used to quantify the displacement of anatomical structures in addition to the tumor. The contouring tool was utilized to localize the tumor and surrogates on the designated frame. The stacks of the contours were exhibited to present the ranges of tumor and surrogate motions. For example, the stacks of the tumor contours from case-1 were used to determine the ranges of tumor motions (∼8.17 mm on the x-direction [AP-direction] and ∼14 mm on the y-direction [SI-direction]). In addition, the patterns of the displacement of the contours over frames were analyzed and reported using in-house software. In the case-1 review, the tumor was displaced from +146.0 mm on the x-direction and +125.0 mm on the y-direction from the ROI of the abdominal surface. CONCLUSION: We demonstrated the institutional solution of clinical cine MRI in radiotherapy. The proposed tools can streamline the utilization of cine MRI for tumor motion evaluation using Eclipse for treatment planning.


Assuntos
Neoplasias Hepáticas , Imagem Cinética por Ressonância Magnética , Humanos , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Movimento (Física) , Respiração
17.
Magn Reson Med ; 85(5): 2842-2855, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33226667

RESUMO

PURPOSE: To develop an approach for automated quantification of myocardial infarct heterogeneity in late gadolinium enhancement (LGE) cardiac MRI. METHODS: We acquired 2D short-axis cine and 3D LGE in 10 pigs with myocardial infarct. The 2D cine myocardium was segmented and registered to the LGE images. LGE image signal intensities within the warped cine myocardium masks were analyzed to determine the thresholds of infarct core (IC) and gray zone (GZ) for the standard-deviation (SD) and full-width-at-halfmaximum (FWHM) methods. The initial IC, GZ, and IC + GZ segmentations were postprocessed using a normalized cut approach. Cine segmentation and cine-LGE registration accuracies were evaluated using dice similarity coefficient and average symmetric surface distance. Automated IC, GZ, and IC + GZ volumes were compared with manual results using Pearson correlation coefficient (r), Bland-Altman analyses, and intraclass correlation coefficient. RESULTS: For n = 87 slices containing scar, we achieved cine segmentation dice similarity coefficient = 0.87 ± 0.12, average symmetric surface distance = 0.94 ± 0.74 mm (epicardium), and 1.03 ± 0.82 mm (endocardium) in the scar region. For cine-LGE registration, dice similarity coefficient was 0.90 ± 0.06 and average symmetric surface distance was 0.72 ± 0.39 mm (epicardium) and 0.86 ± 0.53 mm (endocardium) in the scar region. For both SD and FWHM methods, automated IC, GZ, and IC + GZ volumes were strongly (r > 0.70) correlated with manual measurements, and the correlations were not significantly different from interobserver correlations (P > .05). The agreement between automated and manual scar volumes (intraclass correlation coefficient = 0.85-0.96) was similar to that between two observers (intraclass correlation coefficient = 0.81-0.99); automated scar segmentation errors were not significantly different from interobserver segmentation differences (P > .05). CONCLUSIONS: Our approach provides fully automated cine-LGE MRI registration and LGE myocardial infarct heterogeneity quantification in preclinical studies.


Assuntos
Gadolínio , Infarto do Miocárdio , Animais , Meios de Contraste , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Miocárdio , Reprodutibilidade dos Testes , Suínos
18.
Magn Reson Med ; 86(3): 1674-1686, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33949713

RESUMO

PURPOSE: Amplified MRI (aMRI) has been introduced as a new method of detecting and visualizing pulsatile brain motion in 2D. Here, we improve aMRI by introducing a novel 3D aMRI approach. METHODS: 3D aMRI was developed and tested for its ability to amplify sub-voxel motion in all three directions. In addition, 3D aMRI was qualitatively compared to 2D aMRI on multi-slice and 3D (volumetric) balanced steady-state free precession cine data and phase contrast (PC-MRI) acquired on healthy volunteers at 3T. Optical flow maps and 4D animations were produced from volumetric 3D aMRI data. RESULTS: 3D aMRI exhibits better image quality and fewer motion artifacts compared to 2D aMRI. The tissue motion was seen to match that of PC-MRI, with the predominant brain tissue displacement occurring in the cranial-caudal direction. Optical flow maps capture the brain tissue motion and display the physical change in shape of the ventricles by the relative movement of the surrounding tissues. The 4D animations show the complete brain tissue and cerebrospinal fluid (CSF) motion, helping to highlight the "piston-like" motion of the ventricles. CONCLUSIONS: Here, we introduce a novel 3D aMRI approach that enables one to visualize amplified cardiac- and CSF-induced brain motion in striking detail. 3D aMRI captures brain motion with better image quality than 2D aMRI and supports a larger amplification factor. The optical flow maps and 4D animations of 3D aMRI may open up exciting applications for neurological diseases that affect the biomechanics of the brain and brain fluids.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Artefatos , Encéfalo/diagnóstico por imagem , Humanos , Movimento
19.
NMR Biomed ; 34(11): e4589, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34291517

RESUMO

Abnormal coronary endothelial function (CEF), manifesting as depressed vasoreactive responses to endothelial-specific stressors, occurs early in atherosclerosis, independently predicts cardiovascular events, and responds to cardioprotective interventions. CEF is spatially heterogeneous along a coronary artery in patients with atherosclerosis, and thus recently developed and tested non-invasive 2D MRI techniques to measure CEF may not capture the extent of changes in CEF in a given coronary artery. The purpose of this study was to develop and test the first volumetric coronary 3D MRI cine method for assessing CEF along the proximal and mid-coronary arteries with isotropic spatial resolution and in free-breathing. This approach, called 3D-Stars, combines a 6 min continuous, untriggered golden-angle stack-of-stars acquisition with a novel image-based respiratory self-gating method and cardiac and respiratory motion-resolved reconstruction. The proposed respiratory self-gating method agreed well with respiratory bellows and center-of-k-space methods. In healthy subjects, 3D-Stars vessel sharpness was non-significantly different from that by conventional 2D radial in proximal segments, albeit lower in mid-portions. Importantly, 3D-Stars detected normal vasodilatation of the right coronary artery in response to endothelial-dependent isometric handgrip stress in healthy subjects. Coronary artery cross-sectional areas measured using 3D-Stars were similar to those from 2D radial MRI when similar thresholding was used. In conclusion, 3D-Stars offers good image quality and shows feasibility for non-invasively studying vasoreactivity-related lumen area changes along the proximal coronary artery in 3D during free-breathing.


Assuntos
Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiologia , Endotélio Vascular/diagnóstico por imagem , Endotélio Vascular/fisiologia , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética , Respiração , Adulto , Diástole/fisiologia , Estudos de Viabilidade , Feminino , Humanos , Masculino
20.
NMR Biomed ; 34(1): e4405, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32875668

RESUMO

Highly accelerated real-time cine MRI using compressed sensing (CS) is a promising approach to achieve high spatio-temporal resolution and clinically acceptable image quality in patients with arrhythmia and/or dyspnea. However, its lengthy image reconstruction time may hinder its clinical translation. The purpose of this study was to develop a neural network for reconstruction of non-Cartesian real-time cine MRI k-space data faster (<1 min per slice with 80 frames) than graphics processing unit (GPU)-accelerated CS reconstruction, without significant loss in image quality or accuracy in left ventricular (LV) functional parameters. We introduce a perceptual complex neural network (PCNN) that trains on complex-valued MRI signal and incorporates a perceptual loss term to suppress incoherent image details. This PCNN was trained and tested with multi-slice, multi-phase, cine images from 40 patients (20 for training, 20 for testing), where the zero-filled images were used as input and the corresponding CS reconstructed images were used as practical ground truth. The resulting images were compared using quantitative metrics (structural similarity index (SSIM) and normalized root mean square error (NRMSE)) and visual scores (conspicuity, temporal fidelity, artifacts, and noise scores), individually graded on a five-point scale (1, worst; 3, acceptable; 5, best), and LV ejection fraction (LVEF). The mean processing time per slice with 80 frames for PCNN was 23.7 ± 1.9 s for pre-processing (Step 1, same as CS) and 0.822 ± 0.004 s for dealiasing (Step 2, 166 times faster than CS). Our PCNN produced higher data fidelity metrics (SSIM = 0.88 ± 0.02, NRMSE = 0.014 ± 0.004) compared with CS. While all the visual scores were significantly different (P < 0.05), the median scores were all 4.0 or higher for both CS and PCNN. LVEFs measured from CS and PCNN were strongly correlated (R2 = 0.92) and in good agreement (mean difference = -1.4% [2.3% of mean]; limit of agreement = 10.6% [17.6% of mean]). The proposed PCNN is capable of rapid reconstruction (25 s per slice with 80 frames) of non-Cartesian real-time cine MRI k-space data, without significant loss in image quality or accuracy in LV functional parameters.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Redes Neurais de Computação , Idoso , Compressão de Dados , Feminino , Humanos , Masculino