Resultados 1 - 20 de 87
Filtrar
1.
MAGMA ; 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38916681

RESUMO

PURPOSE: To develop a new MR coronary angiography (MRCA) technique by employing a zigzag fan-shaped centric ky-kz k-space trajectory combined with high-resolution deep learning reconstruction (HR-DLR). METHODS: All imaging data were acquired from 12 healthy subjects and 2 patients using two clinical 3-T MR imagers, with institutional review board approval. Ten healthy subjects underwent both standard 3D fast gradient echo (sFGE) and centric ky-kz k-space trajectory FGE (cFGE) acquisitions to compare the scan time and image quality. Quantitative measures were also performed for signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) as well as sharpness of the vessel. Furthermore, the feasibility of the proposed cFGE sequence was assessed in two patients. For assessing the feasibility of the centric ky-kz trajectory, the navigator-echo window of a 30-mm threshold was applied in cFGE, whereas sFGE was applied using a standard 5-mm threshold. Image quality of MRCA using cFGE with HR-DLR and sFGE without HR-DLR was scored in a 5-point scale (non-diagnostic = 1, fair = 2, moderate = 3, good = 4, and excellent = 5). Image evaluation of cFGE, applying HR-DLR, was compared with sFGE without HR-DLR. Friedman test, Wilcoxon signed-rank test, or paired t tests were performed for the comparison of related variables. RESULTS: The actual MRCA scan time of cFGE with a 30-mm threshold was acquired in less than 5 min, achieving nearly 100% efficiency, showcasing its expeditious and robustness. In contrast, sFGE was acquired with a 5-mm threshold and had an average scan time of approximately 15 min. Overall image quality for MRCA was scored 3.3 for sFGE and 2.7 for cFGE without HR-DLR but increased to 3.6 for cFGE with HR-DLR and (p < 0.05). The clinical result of patients obtained within 5 min showed good quality images in both patients, even with a stent, without artifacts. Quantitative measures of SNR, CNR, and sharpness of vessel presented higher in cFGE with HR-DLR. CONCLUSION: Our findings demonstrate a robust, time-efficient solution for high-quality MRCA, enhancing patient comfort and increasing clinical throughput.

2.
BMC Med Imaging ; 24(1): 127, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38822240

RESUMO

BACKGROUND: The presence of infarction in patients with unrecognized myocardial infarction (UMI) is a critical feature in predicting adverse cardiac events. This study aimed to compare the detection rate of UMI using conventional and deep learning reconstruction (DLR)-based late gadolinium enhancement (LGEO and LGEDL, respectively) and evaluate optimal quantification parameters to enhance diagnosis and management of suspected patients with UMI. METHODS: This prospective study included 98 patients (68 men; mean age: 55.8 ± 8.1 years) with suspected UMI treated at our hospital from April 2022 to August 2023. LGEO and LGEDL images were obtained using conventional and commercially available inline DLR algorithms. The myocardial signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and percentage of enhanced area (Parea) employing the signal threshold versus reference mean (STRM) approach, which correlates the signal intensity (SI) within areas of interest with the average SI of normal regions, were analyzed. Analysis was performed using the standard deviation (SD) threshold approach (2SD-5SD) and full width at half maximum (FWHM) method. The diagnostic efficacies based on LGEDL and LGEO images were calculated. RESULTS: The SNRDL and CNRDL were two times better than the SNRO and CNRO, respectively (P < 0.05). Parea-DL was elevated compared to Parea-O using the threshold methods (P < 0.05); however, no intergroup difference was found based on the FWHM method (P > 0.05). The Parea-DL and Parea-O also differed except between the 2SD and 3SD and the 4SD/5SD and FWHM methods (P < 0.05). The receiver operating characteristic curve analysis revealed that each SD method exhibited good diagnostic efficacy for detecting UMI, with the Parea-DL having the best diagnostic efficacy based on the 5SD method (P < 0.05). Overall, the LGEDL images had better image quality. Strong diagnostic efficacy for UMI identification was achieved when the STRM was ≥ 4SD and ≥ 3SD for the LGEDL and LGEO, respectively. CONCLUSIONS: STRM selection for LGEDL magnetic resonance images helps improve clinical decision-making in patients with UMI. This study underscored the importance of STRM selection for analyzing LGEDL images to enhance diagnostic accuracy and clinical decision-making for patients with UMI, further providing better cardiovascular care.


Assuntos
Meios de Contraste , Aprendizado Profundo , Infarto do Miocárdio , Humanos , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Masculino , Feminino , Estudos Prospectivos , Gadolínio , Razão Sinal-Ruído , Idoso , Imageamento por Ressonância Magnética/métodos
3.
Acta Radiol ; : 2841851241258220, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38839094

RESUMO

BACKGROUND: The diagnostic impact of deep learning computed tomography (CT) reconstruction on intracranial aneurysm (IA) remains unclear. PURPOSE: To quantify the image quality and diagnostic confidence on IA in craniocervical CT angiography (CTA) reconstructed with DEep Learning Trained Algorithm (DELTA) compared to the routine hybrid iterative reconstruction (HIR). MATERIAL AND METHODS: A total of 60 patients who underwent craniocervical CTA and were diagnosed with IA were retrospectively enrolled. Images were reconstructed with DELTA and HIR, where the image quality was first compared in noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Next, two radiologists independently graded the noise appearance, arterial sharpness, small vessel visibility, conspicuity of calcifications that may present in arteries, and overall image quality, each with a 5-point Likert scale. The diagnostic confidence on IAs of various sizes was also graded. RESULTS: Significantly lower noise and higher SNR and CNR were found on DELTA than on HIR images (all P < 0.05). All five subjective metrics were scored higher by both readers on the DELTA images (all P < 0.05), with good to excellent inter-observer agreement (κ = 0.77-0.93). DELTA images were rated with higher diagnostic confidence on IAs compared to HIR (P < 0.001), particularly for those with size ≤3 mm, which were scored 4.5 ± 0.6 versus 3.4 ± 0.8 and 4.4 ± 0.7 versus 3.5 ± 0.8 by two readers, respectively. CONCLUSION: The DELTA shows potential for improving the image quality and the associated confidence in diagnosing IA that may be worth consideration for routine craniocervical CTA applications.

4.
Acta Radiol ; 65(5): 499-505, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38343091

RESUMO

BACKGROUND: The deep learning (DL)-based reconstruction algorithm reduces noise in magnetic resonance imaging (MRI), thereby enabling faster MRI acquisition. PURPOSE: To compare the image quality and diagnostic performance of conventional turbo spin-echo (TSE) T2-weighted (T2W) imaging with DL-accelerated sagittal T2W imaging in the female pelvic cavity. METHODS: This study evaluated 149 consecutive female pelvic MRI examinations, including conventional T2W imaging with TSE (acquisition time = 2:59) and DL-accelerated T2W imaging with breath hold (DL-BH) (1:05 [0:14 × 3 breath-holds]) in the sagittal plane. In 294 randomly ordered sagittal T2W images, two radiologists independently assessed image quality (sharpness, subjective noise, artifacts, and overall image quality), made a diagnosis for uterine leiomyomas, and scored diagnostic confidence. For the uterus and piriformis muscle, quantitative imaging analysis was also performed. Wilcoxon signed rank tests were used to compare the two sets of T2W images. RESULTS: In the qualitative analysis, DL-BH showed similar or significantly higher scores for all features than conventional T2W imaging (P <0.05). In the quantitative analysis, the noise in the uterus was lower in DL-BH, but the noise in the muscle was lower in conventional T2W imaging. In the uterus and muscle, the signal-to-noise ratio was significantly lower in DL-BH than in conventional T2W imaging (P <0.001). The diagnostic performance of the two sets of T2W images was not different for uterine leiomyoma. CONCLUSIONS: DL-accelerated sagittal T2W imaging obtained with three breath-holds demonstrated superior or comparable image quality to conventional T2W imaging with no significant difference in diagnostic performance for uterine leiomyomas.


Assuntos
Aprendizado Profundo , Imageamento por Ressonância Magnética , Pelve , Humanos , Feminino , Imageamento por Ressonância Magnética/métodos , Adulto , Pessoa de Meia-Idade , Pelve/diagnóstico por imagem , Idoso , Leiomioma/diagnóstico por imagem , Neoplasias Uterinas/diagnóstico por imagem , Estudos Retrospectivos , Adulto Jovem , Interpretação de Imagem Assistida por Computador/métodos , Útero/diagnóstico por imagem
5.
Skeletal Radiol ; 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38653786

RESUMO

OBJECTIVE: To prospectively evaluate a deep learning-based denoising reconstruction (DLR) for improved resolution and image quality in musculoskeletal (MSK) magnetic resonance imaging (MRI). METHODS: Images from 137 contrast-weighted sequences in 40 MSK patients were evaluated. Each sequence was performed twice, first with the routine parameters and reconstructed with a routine reconstruction filter (REF), then with higher resolution and reconstructed with DLR, and with three conventional reconstruction filters (NL2, GA43, GA53). The five reconstructions (REF, DLR, NL2, GA43, and GA53) were de-identified, randomized, and blindly reviewed by three MSK radiologists using eight scoring criteria and a forced ranking. Quantitative SNR, CNR, and structure's full width at half maximum (FWHM) for resolution assessment were measured and compared. To account for repeated measures, Generalized Estimating Equations (GEE) with Bonferroni adjustment was used to compare the reader's scores, SNR, CNR, and FWHM between DLR vs. NL2, GA43, GA53, and REF. RESULTS: Compared to the routine REF images, the resolution was improved by 47.61% with DLR from 0.39 ± 0.15 mm2 to 0.20 ± 0.06 mm2 (p < 0.001). Per-sequence average scan time was shortened by 7.93% with DLR from 165.58 ± 21.86 s to 152.45 ± 25.65 s (p < 0.001). Based on the average scores, DLR images were rated significantly higher in all image quality criteria and the forced ranking (p < 0.001). CONCLUSION: This prospective clinical evaluation demonstrated that DLR allows approximately two times finer resolution and improved image quality compared to the standard-of-care images.

6.
Can Assoc Radiol J ; 75(1): 74-81, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37387607

RESUMO

Purpose: We investigated the effect of deep learning reconstruction (DLR) plus single-energy metal artifact reduction (SEMAR) on neck CT in patients with dental metals, comparing it with DLR and with hybrid iterative reconstruction (Hybrid IR)-SEMAR. Methods: In this retrospective study, 32 patients (25 men, 7 women; mean age: 63 ± 15 years) with dental metals underwent contrast-enhanced CT of the oral and oropharyngeal regions. Axial images were reconstructed using DLR, Hybrid IR-SEMAR, and DLR-SEMAR. In quantitative analyses, degrees of image noise and artifacts were evaluated. In one-by-one qualitative analyses, 2 radiologists evaluated metal artifacts, the depiction of structures, and noise on five-point scales. In side-by-side qualitative analyses, artifacts and overall image quality were evaluated by comparing Hybrid IR-SEMAR with DLR-SEMAR. Results: Artifacts were significantly less with DLR-SEMAR than with DLR in quantitative (P < .001) and one-by-one qualitative (P < .001) analyses, which resulted in significantly better depiction of most structures (P < .004). Artifacts in side-by-side analysis and image noise in quantitative and one-by-one qualitative analyses (P < .001) were significantly less with DLR-SEMAR than with Hybrid IR-SEMAR, resulting in significantly better overall quality of DLR-SEMAR. Conclusions: Compared with DLR and Hybrid IR-SEMAR, DLR-SEMAR provided significantly better supra hyoid neck CT images in patients with dental metals.


Assuntos
Artefatos , Aprendizado Profundo , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação
7.
Can Assoc Radiol J ; : 8465371241228468, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38293802

RESUMO

Objective: This study aimed to investigate whether deep-learning reconstruction (DLR) improves interobserver agreement in the evaluation of honeycombing for patients with interstitial lung disease (ILD) who underwent high-resolution computed tomography (CT) compared with hybrid iterative reconstruction (HIR). Methods: In this retrospective study, 35 consecutive patients suspected of ILD who underwent CT including the chest region were included. High-resolution CT images of the unilateral lung with DLR and HIR were reconstructed for the right and left lungs. A radiologist placed regions of interest on the lung and measured standard deviation of CT attenuation (i.e., quantitative image noise). In the qualitative image analyses, 5 blinded readers assessed the presence of honeycombing and reticulation, qualitative image noise, artifacts, and overall image quality using a 5-point scale (except for artifacts which was evaluated using a 3-point scale). Results: The quantitative and qualitative image noise in DLR was remarkably reduced compared to that in HIR (P < .001). Artifacts and overall DLR quality were significantly improved compared to those of HIR (P < .001 for 4 out of 5 readers). Interobserver agreement in the evaluations of honeycombing and reticulation for DLR (0.557 [0.450-0.693] and 0.525 [0.470-0.541], respectively) were higher than those for HIR (0.321 [0.211-0.520] and 0.470 [0.354-0.533], respectively). A statistically significant difference was found for honeycombing (P = .014). Conclusions: DLR improved interobserver agreement in the evaluation of honeycombing in patients with ILD on CT compared to HIR.

8.
Magn Reson Med ; 89(4): 1567-1585, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36426730

RESUMO

PURPOSE: To develop a deep learning-based method for rapid liver proton-density fat fraction (PDFF) and R2 * quantification with built-in uncertainty estimation using self-gated free-breathing stack-of-radial MRI. METHODS: This work developed an uncertainty-aware physics-driven deep learning network (UP-Net) to (1) suppress radial streaking artifacts because of undersampling after self-gating, (2) calculate accurate quantitative maps, and (3) provide pixel-wise uncertainty maps. UP-Net incorporated a phase augmentation strategy, generative adversarial network architecture, and an MRI physics loss term based on a fat-water and R2 * signal model. UP-Net was trained and tested using free-breathing multi-echo stack-of-radial MRI data from 105 subjects. UP-Net uncertainty scores were calibrated in a validation dataset and used to predict quantification errors for liver PDFF and R2 * in a testing dataset. RESULTS: Compared with images reconstructed using compressed sensing (CS), UP-Net achieved structural similarity index >0.87 and normalized root mean squared error <0.18. Compared with reference quantitative maps generated using CS and graph-cut (GC) algorithms, UP-Net achieved low mean differences (MD) for liver PDFF (-0.36%) and R2 * (-0.37 s-1 ). Compared with breath-holding Cartesian MRI results, UP-Net achieved low MD for liver PDFF (0.53%) and R2 * (6.75 s-1 ). UP-Net uncertainty scores predicted absolute liver PDFF and R2 * errors with low MD of 0.27% and 0.12 s-1 compared to CS + GC results. The computational time for UP-Net was 79 ms/slice, whereas CS + GC required 3.2 min/slice. CONCLUSION: UP-Net rapidly calculates accurate liver PDFF and R2 * maps from self-gated free-breathing stack-of-radial MRI. The pixel-wise uncertainty maps from UP-Net predict quantification errors in the liver.


Assuntos
Aprendizado Profundo , Humanos , Incerteza , Interpretação de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Prótons
9.
AJR Am J Roentgenol ; 220(3): 381-388, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36259592

RESUMO

BACKGROUND. Because thick-section images (typically 3-5 mm) have low image noise, radiologists typically use them to perform clinical interpretation, although they may additionally refer to thin-section images (typically 0.5-0.625 mm) for problem solving. Deep learning reconstruction (DLR) can yield thin-section images with low noise. OBJECTIVE. The purpose of this study is to compare abdominopelvic CT image quality between thin-section DLR images and thin- and thick-section hybrid iterative reconstruction (HIR) images. METHODS. This retrospective study included 50 patients (31 men and 19 women; median age, 64 years) who underwent abdominopelvic CT between June 15, 2020, and July 29, 2020. Images were reconstructed at 0.5-mm section using DLR and at 0.5-mm and 3.0-mm sections using HIR. Five radiologists independently performed pairwise comparisons (0.5-mm DLR and either 0.5-mm or 3.0-mm HIR) and recorded the preferred image for subjective image quality measures (scale, -2 to 2). The pooled scores of readers were compared with a score of 0 (denoting no preference). Image noise was quantified using the SD of ROIs on regions of homogeneous liver. RESULTS. For comparison of 0.5-mm DLR images and 0.5-mm HIR images, the median pooled score was 2 (indicating a definite preference for DLR) for noise and overall image quality and 1 (denoting a slight preference for DLR) for sharpness and natural appearance. For comparison of 0.5-mm DLR and 3.0-mm HIR, the median pooled score was 1 for the four previously mentioned measures. These assessments were all significantly different (p < .001) from 0. For artifacts, the median pooled score for both comparisons was 0, which was not significant for comparison with 3.0-mm HIR (p = .03) but was significant for comparison with 0.5-mm HIR (p < .001) due to imbalance in scores of 1 (n = 28) and -1 (slight preference for HIR, n = 1). Noise for 0.5-mm DLR was lower by mean differences of 12.8 HU compared with 0.5-mm HIR and 4.4 HU compared with 3.0-mm HIR (both p < .001). CONCLUSION. Thin-section DLR improves subjective image quality and reduces image noise compared with currently used thin- and thick-section HIR, without causing additional artifacts. CLINICAL IMPACT. Although further diagnostic performance studies are warranted, the findings suggest the possibility of replacing current use of both thin- and thick-section HIR with the use of thin-section DLR only during clinical interpretations.


Assuntos
Aprendizado Profundo , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos
10.
Pain Med ; 24(Suppl 1): S149-S159, 2023 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-36943371

RESUMO

OBJECTIVES: To evaluate whether combining fast acquisitions with deep-learning reconstruction can provide diagnostically useful images and quantitative assessment comparable to standard-of-care acquisitions for lumbar spine magnetic resonance imaging (MRI). METHODS: Eighteen patients were imaged with both standard protocol and fast protocol using reduced signal averages, each protocol including sagittal fat-suppressed T2-weighted, sagittal T1-weighted, and axial T2-weighted 2D fast spin-echo sequences. Fast-acquisition data was additionally reconstructed using vendor-supplied deep-learning reconstruction with three different noise reduction factors. For qualitative analysis, standard images as well as fast images with and without deep-learning reconstruction were graded by three radiologists on five different categories. For quantitative analysis, convolutional neural networks were applied to sagittal T1-weighted images to segment intervertebral discs and vertebral bodies, and disc heights and vertebral body volumes were derived. RESULTS: Based on noninferiority testing on qualitative scores, fast images without deep-learning reconstruction were inferior to standard images for most categories. However, deep-learning reconstruction improved the average scores, and noninferiority was observed over 24 out of 45 comparisons (all with sagittal T2-weighted images while 4/5 comparisons with sagittal T1-weighted and axial T2-weighted images). Interobserver variability increased with 50 and 75% noise reduction factors. Deep-learning reconstructed fast images with 50% and 75% noise reduction factors had comparable disc heights and vertebral body volumes to standard images (r2≥ 0.86 for disc heights and r2≥ 0.98 for vertebral body volumes). CONCLUSIONS: This study demonstrated that deep-learning-reconstructed fast-acquisition images have the potential to provide noninferior image quality and comparable quantitative assessment to standard clinical images.


Assuntos
Aprendizado Profundo , Humanos , Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Tecnologia
11.
BMC Med Imaging ; 23(1): 171, 2023 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-37904089

RESUMO

A super-resolution deep learning reconstruction (SR-DLR) algorithm trained using data acquired on the ultrahigh spatial resolution computed tomography (UHRCT) has the potential to provide better image quality of coronary arteries on the whole-heart, single-rotation cardiac coverage on a 320-detector row CT scanner. However, the advantages of SR-DLR at coronary computed tomography angiography (CCTA) have not been fully investigated. The present study aimed to compare the image quality of the coronary arteries and in-stent lumen between SR-DLR and model-based iterative reconstruction (MBIR). We prospectively enrolled 70 patients (median age, 69 years; interquartile range [IQR], 59-75 years; 50 men) who underwent CCTA using a 320-detector row CT scanner between January and August 2022. The image noise in the ascending aorta, left atrium, and septal wall of the ventricle was measured, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in the proximal coronary arteries were calculated. Of the twenty stents, stent strut thickness and luminal diameter were quantitatively evaluated. The image noise on SR-DLR was significantly lower than that on MBIR (median 22.1 HU; IQR, 19.3-24.9 HU vs. 27.4 HU; IQR, 24.2-31.2 HU, p < 0.01), whereas the SNR (median 16.3; IQR, 11.8-21.8 vs. 13.7; IQR, 9.9-18.4, p = 0.01) and CNR (median 24.4; IQR, 15.5-30.2 vs. 19.2; IQR, 14.1-23.2, p < 0.01) on SR-DLR were significantly higher than that on MBIR. Stent struts were significantly thinner (median, 0.68 mm; IQR, 0.61-0.78 mm vs. 0.81 mm; IQR, 0.72-0.96 mm, p < 0.01) and in-stent lumens were significantly larger (median, 1.84 mm; IQR, 1.65-2.26 mm vs. 1.52 mm; IQR, 1.28-2.25 mm, p < 0.01) on SR-DLR than on MBIR. Although further large-scale studies using invasive coronary angiography as the reference standard, comparative studies with UHRCT, and studies in more challenging population for CCTA are needed, this study's initial experience with SR-DLR would improve the utility of CCTA in daily clinical practice due to the better image quality of the coronary arteries and in-stent lumen at CCTA compared with conventional MBIR.


Assuntos
Angiografia por Tomografia Computadorizada , Aprendizado Profundo , Masculino , Humanos , Idoso , Angiografia por Tomografia Computadorizada/métodos , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Angiografia Coronária/métodos , Stents , Átrios do Coração , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Doses de Radiação
12.
Pediatr Radiol ; 53(11): 2260-2268, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37488451

RESUMO

BACKGROUND: Craniofacial computed tomography (CT) is the diagnostic investigation of choice for craniosynostosis, but high radiation dose remains a concern. OBJECTIVE: To evaluate the image quality and diagnostic performance of an ultra-low-dose craniofacial CT protocol with deep learning reconstruction for diagnosis of craniosynostosis. MATERIALS AND METHODS: All children who underwent initial craniofacial CT for suspected craniosynostosis between September 2021 and September 2022 were included in the study. The ultra-low-dose craniofacial CT protocol using 70 kVp, model-based iterative reconstruction and deep learning reconstruction techniques was compared with a routine-dose craniofacial CT protocol. Quantitative analysis of the signal-to-noise ratio and noise was performed. The 3-dimensional (D) volume-rendered images were independently evaluated by two radiologists with regard to surface coarseness, step-off artifacts and overall image quality on a 5-point scale. Sutural patency was assessed for each of six sutures. Radiation dose was compared between the two protocols. RESULTS: Among 29 patients (15 routine-dose CT and 14 ultra-low-dose CT), 23 patients had craniosynostosis. The 3-D volume-rendered images of ultra-low-dose CT without deep learning showed decreased image quality compared to routine-dose CT. The 3-D volume-rendered images of ultra-low-dose CT with deep learning reconstruction showed higher noise level, higher surface coarseness but decreased step-off artifacts, comparable signal-to-noise ratio and overall similar image quality compared to the routine-dose CT images. Diagnostic performance for detecting craniosynostosis at the suture level showed no significant difference between ultra-low-dose CT without deep learning reconstruction, ultra-low-dose CT with deep learning reconstruction and routine-dose CT. The estimated effective radiation dose for the ultra-low-dose CT was 0.05 mSv (range, 0.03-0.06 mSv), a 95% reduction in dose over the routine-dose CT at 1.15 mSv (range, 0.54-1.74 mSv). This radiation dose is comparable to 4-view skull radiography (0.05-0.1 mSv) and lower than previously reported effective dose for craniosynostosis protocols (0.08-3.36 mSv). CONCLUSION: In this pilot study, an ultra-low-dose CT protocol using radiation doses at a level similar to skull radiographs showed preserved diagnostic performance for craniosynostosis, but decreased image quality compared to the routine-dose CT protocol. However, by combining the ultra-low-dose CT protocol with deep learning reconstruction, image quality was improved to a level comparable to the routine-dose CT protocol, without sacrificing diagnostic performance for craniosynostosis.


Assuntos
Craniossinostoses , Aprendizado Profundo , Criança , Humanos , Projetos Piloto , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Craniossinostoses/diagnóstico por imagem , Crânio , Algoritmos
13.
Can Assoc Radiol J ; : 8465371231203508, 2023 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-37795610

RESUMO

PURPOSE: To compare the impact of deep learning reconstruction (DLR) and hybrid-iterative reconstruction (hybrid-IR) on vertebral mass depiction, detection, and diagnosis of spinal cord compression on computed tomography (CT). METHODS: This retrospective study included 29 and 20 patients with and without vertebral masses. CT images were reconstructed using DLR and hybrid-IR. Three readers performed vertebral mass detection tests and evaluated the presence of spinal cord compression, the depiction of vertebral masses, and image noise. Quantitative image noise was measured by placing regions of interest on the aorta and spinal cord. RESULTS: Deep learning reconstruction tended to improve the performance of readers with less diagnostic imaging experience in detecting vertebral masses (area under the receiver operating characteristic curve [AUC] = .892-.966) compared with hybrid-IR (AUC = .839-.917). Diagnostic performance in evaluating spinal cord compression in DLR (AUC = .887-.995) also improved compared with that in hybrid-IR (AUC = .866-.942) for some readers. The depiction of vertebral masses and subjective image noise in DLR were significantly improved compared with those in hybrid-IR (P < .041). Quantitative image noise in DLR was also significantly reduced compared with that in hybrid-IR (P < .001). CONCLUSION: Deep learning reconstruction improved the depiction of vertebral masses, which resulted in a tendency to improve the performance of CT compared to hybrid-IR in detecting vertebral masses and diagnosing spinal cord compression for some readers.

14.
J Xray Sci Technol ; 31(2): 409-422, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36744361

RESUMO

BACKGROUND: Recently, deep learning reconstruction (DLR) technology aiming to improve image quality with minimal radiation dose has been applied not only to pediatric scans, but also to computed tomography angiography (CTA). OBJECTIVE: To evaluate image quality characteristics of filtered back projection (FBP), hybrid iterative reconstruction [Adaptive Iterative Dose Reduction 3D (AIDR 3D)], and DLR (AiCE) using different iodine concentrations and scan parameters. METHODS: Phantoms with eight iodine concentrations (ranging from 1.2 to 25.9 mg/mL) located at the edge of a cylindrical water phantom with a diameter of 19 cm were scanned. Data were reconstructed with FBP, AIDR 3D, and AiCE using various scan parameters of tube current and voltage using a 320 row-detector CT scanner. Data obtained using different reconstruction techniques were quantitatively compared by analyzing Hounsfield units (HU), noise, and contrast-to-noise ratios (CNRs). RESULTS: HU values of FBP and AIDR 3D were constant even when the iodine concentration was changed, whereas AiCE showed the highest HU value when the iodine concentration was low, but the HU value reversed when the iodine concentration exceeded a certain value. In the AIDR 3D and AiCE, the noise decreased as the tube current increased, and the change in noise when the iodine concentration was inconsistent. AIDR 3D and AiCE yielded better noise reduction rates than with FBP at a low tube current. The noise reduction rate of AIDR 3D and AiCE compared to that of FBP showed characteristics ranging from 7% to 35%, and the noise reduction rate of AiCE compared to that of AIDR 3D ranged from 2.0% to 13.3%. CONCLUSIONS: The evaluated reconstruction techniques showed different image quality characteristics (HU value, noise, and CNR) according to dose and scan parameters, and users must consider these results and characteristics before performing patient scans.


Assuntos
Aprendizado Profundo , Humanos , Criança , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada , Imagens de Fantasmas , Algoritmos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos
15.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 45(3): 416-421, 2023 Jun.
Artigo em Chinês | MEDLINE | ID: mdl-37407528

RESUMO

Objective To evaluate the impact of deep learning reconstruction algorithm on the image quality of head and neck CT angiography (CTA) at 100 kVp. Methods CT scanning was performed at 100 kVp for the 37 patients who underwent head and neck CTA in PUMC Hospital from March to April in 2021.Four sets of images were reconstructed by three-dimensional adaptive iterative dose reduction (AIDR 3D) and advanced intelligent Clear-IQ engine (AiCE) (low,medium,and high intensity algorithms),respectively.The average CT value,standard deviation (SD),signal-to-noise ratio (SNR),and contrast-to-noise ratio (CNR) of the region of interest in the transverse section image were calculated.Furthermore,the four sets of sagittal maximum intensity projection images of the anterior cerebral artery were scored (1 point:poor,5 points:excellent). Results The SNR and CNR showed differences in the images reconstructed by AiCE (low,medium,and high intensity) and AIDR 3D (all P<0.01).The quality scores of the image reconstructed by AiCE (low,medium,and high intensity) and AIDR 3D were 4.78±0.41,4.92±0.27,4.97±0.16,and 3.92±0.27,respectively,which showed statistically significant differences (all P<0.001). Conclusion AiCE outperformed AIDR 3D in reconstructing the images of head and neck CTA at 100 kVp,being capable of improving image quality and applicable in clinical examinations.


Assuntos
Angiografia por Tomografia Computadorizada , Aprendizado Profundo , Humanos , Angiografia por Tomografia Computadorizada/métodos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Razão Sinal-Ruído , Algoritmos
16.
J Magn Reson Imaging ; 55(6): 1735-1744, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34773449

RESUMO

BACKGROUND: Deep learning-based reconstruction (DLR) can potentially improve image quality by reduction of noise, thereby enabling fast acquisition of magnetic resonance imaging (MRI). However, a systematic evaluation of image quality and diagnostic performance of MRI using short acquisition time with DLR has rarely been investigated in men with prostate cancer. PURPOSE: To assess the image quality and diagnostic performance of MRI using short acquisition time with DLR for the evaluation of extraprostatic extension (EPE). STUDY TYPE: Retrospective. POPULATION: One hundred and nine men. FIELD STRENGTH/SEQUENCE: 3 T; turbo spin echo T2-weighted images (T2WI), echo-planar diffusion-weighted, and spoiled gradient echo dynamic contrast-enhanced images. ASSESSMENT: To compare image quality, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) and subjective analysis using Likert scales on three T2WIs (MRI using conventional acquisition time, MRI using short acquisition time [fast MRI], and fast MRI with DLR) were performed. The diagnostic performance for EPE was evaluated by three independent readers. STATISTICAL TESTS: SNR, CNR, and image quality scores across the three imaging protocols were compared using Friedman tests. The diagnostic performance for EPE was assessed using the area under receiver operating characteristic curves (AUCs). P < 0.05 was considered statistically significant. RESULTS: Fast MRI with DLR demonstrated significantly higher SNR (mean ± SD, 14.7 ± 6.8 vs. 8.8 ± 4.9) and CNR (mean ± SD, 6.5 ± 6.3 vs. 3.4 ± 3.6) values and higher image quality scores (median, 4.0 vs. 3.0 for three readers) than fast MRI. The AUCs for EPE were significantly higher with the use of DLR (0.86 vs. 0.75 for reader 2 and 0.82 vs. 0.73 for reader 3) compared with fast MRI, whereas differences were not significant for reader 1 (0.81 vs. 0.74; P = 0.09). DATA CONCLUSION: DLR may be useful in reducing the acquisition time of prostate MRI without compromising image quality or diagnostic performance. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 3.


Assuntos
Aprendizado Profundo , Próstata , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Prostatectomia , Estudos Retrospectivos
17.
Eur Radiol ; 32(9): 6215-6229, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35389046

RESUMO

OBJECTIVES: The aim of this study was to evaluate the image quality and diagnostic performance of a deep-learning (DL)-accelerated two-dimensional (2D) turbo spin echo (TSE) MRI of the knee at 1.5 and 3 T in clinical routine in comparison to standard MRI. MATERIAL AND METHODS: Sixty participants, who underwent knee MRI at 1.5 and 3 T between October/2020 and March/2021 with a protocol using standard 2D-TSE (TSES) and DL-accelerated 2D-TSE sequences (TSEDL), were enrolled in this prospective institutional review board-approved study. Three radiologists assessed the sequences regarding structural abnormalities and evaluated the images concerning overall image quality, artifacts, noise, sharpness, subjective signal-to-noise ratio, and diagnostic confidence using a Likert scale (1-5, 5 = best). RESULTS: Overall image quality for TSEDL was rated to be excellent (median 5, IQR 4-5), significantly higher compared to TSES (median 5, IQR 4 - 5, p < 0.05), showing significantly lower extents of noise and improved sharpness (p < 0.001). Inter- and intra-reader agreement was almost perfect (κ = 0.92-1.00) for the detection of internal derangement and substantial to almost perfect (κ = 0.58-0.98) for the assessment of cartilage defects. No difference was found concerning the detection of bone marrow edema and fractures. The diagnostic confidence of TSEDL was rated to be comparable to that of TSES (median 5, IQR 5-5, p > 0.05). Time of acquisition could be reduced to 6:11 min using TSEDL compared to 11:56 min for a protocol using TSES. CONCLUSION: TSEDL of the knee is clinically feasible, showing excellent image quality and equivalent diagnostic performance compared to TSES, reducing the acquisition time about 50%. KEY POINTS: • Deep-learning reconstructed TSE imaging is able to almost halve the acquisition time of a three-plane knee MRI with proton density and T1-weighted images, from 11:56 min to 6:11 min at 3 T. • Deep-learning reconstructed TSE imaging of the knee provided significant improvement of noise levels (p < 0.001), providing higher image quality (p < 0.05) compared to conventional TSE imaging. • Deep-learning reconstructed TSE imaging of the knee had similar diagnostic performance for internal derangement of the knee compared to standard TSE.


Assuntos
Aprendizado Profundo , Imageamento Tridimensional , Artefatos , Estudos de Viabilidade , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos
18.
J Appl Clin Med Phys ; 23(11): e13759, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35998185

RESUMO

OBJECTIVE: To investigate the feasibility and accuracy of applying a computed tomography (CT) texture analysis model trained with deep-learning reconstruction images to iterative reconstruction images for classifying pulmonary nodules. MATERIALS AND METHODS: CT images of 102 patients, with a total of 118 pulmonary nodules (52 benign, 66 malignant) were retrospectively reconstructed with a deep-learning reconstruction (artificial intelligence iterative reconstruction [AIIR]) and a hybrid iterative reconstruction (HIR) technique. The AIIR data were divided into a training (n = 96) and a validation set (n = 22), and the HIR data were set as the test set (n = 118). Extracted texture features were compared using the Mann-Whitney U test and t-test. The diagnostic performance of the classification model was analyzed with the receiver operating characteristic curve (ROC), the area under ROC (AUC), sensitivity, specificity, and accuracy. RESULTS: Among the obtained 68 texture features, 51 (75.0%) were not influenced by the change of reconstruction algorithm (p > 0.05). Forty-four features were significantly different between benign and malignant nodules (p < 0.05) for the AIIR dataset, which were selected to build the classification model. The accuracy and AUC of the classification model were 92.3% and 0.91 (95% confidence interval [CI], 0.74-0.90) with the validation set, which were 80.0% and 0.80 (95% CI, 0.68-0.86) with the test set. CONCLUSION: With the CT texture analysis model trained with deep-learning reconstruction (AIIR) images showing favorable diagnostic accuracy in discriminating benign and malignant pulmonary nodules, it also has certain applicability to the iterative reconstruction (HIR) images.


Assuntos
Aprendizado Profundo , Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Nódulo Pulmonar Solitário , Humanos , Inteligência Artificial , Estudos Retrospectivos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/patologia , Tomografia Computadorizada por Raios X/métodos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Nódulo Pulmonar Solitário/patologia
19.
J Digit Imaging ; 35(1): 77-85, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34761322

RESUMO

This study aims to devise a simple method for evaluating the magnitude of texture noise (apparent noise) observed on computed tomography (CT) images scanned at a low radiation dose and reconstructed using iterative reconstruction (IR) and deep learning reconstruction (DLR) algorithms, and to evaluate the apparent noise in CT images reconstructed using the filtered back projection (FBP), IR, and two types of DLR (AiCE Body and AiCE Body Sharp) algorithms. We set a square region of interest (ROI) on CT images of standard- and obese-sized low-contrast phantoms, slid different-sized moving average filters in the ROI vertically and horizontally in steps of 1 pixel, and calculated the standard deviation (SD) of the mean CT values for each filter size. The SD of the mean CT values was fitted with a curve inversely proportional to the filter size, and an apparent noise index was determined from the curve-fitting formula. The apparent noise index of AiCE Body Sharp images for a given mAs value was approximately 58, 23, and 18% lower than that of the FBP, AIDR 3D, and AiCE Body images, respectively. The apparent noise index was considered to reflect noise power spectrum values at lower spatial frequency. Moreover, the apparent noise index was inversely proportional to the square roots of the mAs values. Thus, the apparent noise index could be a useful indicator to quantify and compare texture noise on CT images obtained with different scan parameters and reconstruction algorithms.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Algoritmos , Humanos , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos
20.
Magn Reson Med ; 86(4): 1983-1996, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34096095

RESUMO

PURPOSE: To develop an end-to-end deep learning technique for nonrigid motion-corrected (MoCo) reconstruction of ninefold undersampled free-breathing whole-heart coronary MRA (CMRA). METHODS: A novel deep learning framework was developed consisting of a diffeomorphic registration network and a motion-informed model-based deep learning (MoDL) reconstruction network. The registration network receives as input highly undersampled (~22×) respiratory-resolved images and outputs 3D nonrigid respiratory motion fields between the images. The motion-informed MoDL performs MoCo reconstruction from undersampled data using the predicted motion fields. The whole deep learning framework, termed as MoCo-MoDL, was trained end-to-end in a supervised manner for simultaneous 3D nonrigid motion estimation and MoCo reconstruction. MoCo-MoDL was compared with a state-of-the-art nonrigid MoCo CMRA reconstruction technique in 15 retrospectively undersampled datasets and 9 prospectively undersampled acquisitions. RESULTS: The acquisition time for ninefold accelerated CMRA was ~2.5 min. The reconstruction time was ~22 s for the proposed MoCo-MoDL and ~35 min for the conventional approach. MoCo-MoDL achieved higher peak SNR (27.86 ± 3.00 vs. 26.71 ± 2.79; P < .05) and structural similarity (0.78 ± 0.06 vs. 0.75 ± 0.06; P < .05) than the conventional approach. Similar vessel length and visual image quality score were obtained with the 2 methods, whereas improved vessel sharpness was observed with MoCo-MoDL. CONCLUSION: An end-to-end deep learning approach was introduced for simultaneous nonrigid motion estimation and MoCo reconstruction of highly undersampled free-breathing whole-heart CMRA. The rapid free-breathing CMRA acquisition together with the fast reconstruction of the proposed approach promises easy integration into clinical workflow.


Assuntos
Aprendizado Profundo , Angiografia por Ressonância Magnética , Coração , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Movimento (Física) , Estudos Retrospectivos