Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 642
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Gastroenterology ; 164(6): 906-920, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36736437

RESUMO

BACKGROUND & AIMS: The use of computer-aided detection (CAD) increases the adenoma detection rates (ADRs) during colorectal cancer (CRC) screening/surveillance. This study aimed to evaluate the requirements for CAD to be cost-effective and the impact of CAD on adenoma detection by endoscopists with different ADRs. METHODS: We developed a semi-Markov microsimulation model to compare the effectiveness of traditional colonoscopy (mean ADR, 26%) to colonoscopy with CAD (mean ADR, 37%). CAD was modeled as having a $75 per-procedure cost. Extensive 1-way sensitivity and threshold analysis were performed to vary cost and ADR of CAD. Multiple scenarios evaluated the potential effect of CAD on endoscopists' ADRs. Outcome measures were reported in incremental cost-effectiveness ratios, with a willingness-to-pay threshold of $100,000/quality-adjusted life year. RESULTS: When modeling CAD improved ADR for all endoscopists, the CAD cohort had 79 and 34 fewer lifetime CRC cases and deaths, respectively, per 10,000 persons. This scenario was dominant with a cost savings of $143 and incremental effectiveness of 0.01 quality-adjusted life years. Threshold analysis demonstrated that CAD would be cost-effective up to an additional cost of $579 per colonoscopy, or if it increases ADR from 26% to at least 30%. CAD reduced CRC incidence and mortality when limited to improving ADRs for low-ADR endoscopists (ADR <25%), with 67 fewer CRC cases and 28 CRC deaths per 10,000 persons compared with traditional colonoscopy. CONCLUSIONS: As CAD is implemented clinically, it needs to improve mean ADR from 26% to at least 30% or cost less than $579 per colonoscopy to be cost-effective when compared with traditional colonoscopy. Further studies are needed to understand the impact of CAD when used in community practice.


Assuntos
Adenoma , Neoplasias Colorretais , Humanos , Análise Custo-Benefício , Colonoscopia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/epidemiologia , Adenoma/diagnóstico , Detecção Precoce de Câncer , Computadores
2.
Clin Gastroenterol Hepatol ; 22(3): 630-641.e4, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37918685

RESUMO

BACKGROUND: The effect of computer-aided polyp detection (CADe) on adenoma detection rate (ADR) among endoscopists-in-training remains unknown. METHODS: We performed a single-blind, parallel-group, randomized controlled trial in Hong Kong between April 2021 and July 2022 (NCT04838951). Eligible subjects undergoing screening/surveillance/diagnostic colonoscopies were randomized 1:1 to receive colonoscopies with CADe (ENDO-AID[OIP-1]) or not (control) during withdrawal. Procedures were performed by endoscopists-in-training with <500 procedures and <3 years' experience. Randomization was stratified by patient age, sex, and endoscopist experience (beginner vs intermediate level, <200 vs 200-500 procedures). Image enhancement and distal attachment devices were disallowed. Subjects with incomplete colonoscopies or inadequate bowel preparation were excluded. Treatment allocation was blinded to outcome assessors. The primary outcome was ADR. Secondary outcomes were ADR for different adenoma sizes and locations, mean number of adenomas, and non-neoplastic resection rate. RESULTS: A total of 386 and 380 subjects were randomized to CADe and control groups, respectively. The overall ADR was significantly higher in the CADe group than in the control group (57.5% vs 44.5%; adjusted relative risk, 1.41; 95% CI, 1.17-1.72; P < .001). The ADRs for <5 mm (40.4% vs 25.0%) and 5- to 10-mm adenomas (36.8% vs 29.2%) were higher in the CADe group. The ADRs were higher in the CADe group in both the right colon (42.0% vs 30.8%) and left colon (34.5% vs 27.6%), but there was no significant difference in advanced ADR. The ADRs were higher in the CADe group among beginner (60.0% vs 41.9%) and intermediate-level (56.5% vs 45.5%) endoscopists. Mean number of adenomas (1.48 vs 0.86) and non-neoplastic resection rate (52.1% vs 35.0%) were higher in the CADe group. CONCLUSIONS: Among endoscopists-in-training, the use of CADe during colonoscopies was associated with increased overall ADR. (ClinicalTrials.gov, Number: NCT04838951).


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Pólipos , Humanos , Neoplasias Colorretais/diagnóstico , Método Simples-Cego , Colonoscopia/métodos , Adenoma/diagnóstico , Computadores , Pólipos do Colo/diagnóstico
3.
Artigo em Inglês | MEDLINE | ID: mdl-38437999

RESUMO

BACKGROUND & AIMS: The use of computer-aided detection (CADe) has increased the adenoma detection rates (ADRs) during colorectal cancer (CRC) screening/surveillance in randomized controlled trials (RCTs) but has not shown benefit in real-world implementation studies. We performed a single-center pragmatic RCT to evaluate the impact of real-time CADe on ADRs in colonoscopy performed by community gastroenterologists. METHODS: We enrolled 1100 patients undergoing colonoscopy for CRC screening, surveillance, positive fecal-immunohistochemical tests, and diagnostic indications at one community-based center from September 2022 to March 2023. Patients were randomly assigned (1:1) to traditional colonoscopy or real-time CADe. Blinded pathologists analyzed histopathologic findings. The primary outcome was ADR (the percentage of patients with at least 1 histologically proven adenoma or carcinoma). Secondary outcomes were adenomas detected per colonoscopy (APC), sessile-serrated lesion detection rate, and non-neoplastic resection rate. RESULTS: The median age was 55.5 years (interquartile range, 50-62 years), 61% were female, 72.7% were of Hispanic ethnicity, and 9.1% had inadequate bowel preparation. The ADR for the CADe group was significantly higher than the traditional colonoscopy group (42.5% vs 34.4%; P = .005). The mean APC was significantly higher in the CADe group compared with the traditional colonoscopy group (0.89 ± 1.46 vs 0.60 ± 1.12; P < .001). The improvement in adenoma detection was driven by increased detection of <5 mm adenomas. CADe had a higher sessile-serrated lesion detection rate than traditional colonoscopy (4.7% vs 2.0%; P = .01). The improvement in ADR with CADe was significantly higher in the first half of the study (47.2% vs 33.7%; P = .002) compared with the second half (38.7% vs 34.9%; P = .33). CONCLUSIONS: In a single-center pragmatic RCT, real-time CADe modestly improved ADR and APC in average-detector community endoscopists. (ClinicalTrials.gov number, NCT05963724).

4.
Appl Environ Microbiol ; 90(4): e0000724, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38501861

RESUMO

With its estrogenic activity, (S)-equol plays an important role in maintaining host health and preventing estrogen-related diseases. Exclusive production occurs through the transformation of soy isoflavones by intestinal bacteria, but the reasons for variations in (S)-equol production among different individuals and species remain unclear. Here, fecal samples from humans, pigs, chickens, mice, and rats were used as research objects. The concentrations of (S)-equol, along with the genetic homology and evolutionary relationships of (S)-equol production-related genes [daidzein reductase (DZNR), daidzein racemase (DDRC), dihydrodaidzein reductase (DHDR), tetrahydrodaidzein reductase (THDR)], were analyzed. Additionally, in vitro functional verification of the newly identified DDRC gene was conducted. It was found that approximately 40% of human samples contained (S)-equol, whereas 100% of samples from other species contained (S)-equol. However, there were significant variations in (S)-equol content among the different species: rats > pigs > chickens > mice > humans. The distributions of the four genes displayed species-specific patterns. High detection rates across various species were exhibited by DHDR, THDR, and DDRC. In contrast, substantial variations in detection rates among different species and individuals were observed with respect to DZNR. It appears that various types of DZNR may be associated with different concentrations of (S)-equol, which potentially correspond to the regulatory role during (S)-equol synthesis. This enhances our understanding of individual variations in (S)-equol production and their connection with functional genes in vitro. Moreover, the newly identified DDRC exhibits higher potential for (S)-equol synthesis compared to the known DDRC, providing valuable resources for advancing in vitro (S)-equol production. IMPORTANCE: (S)-equol ((S)-EQ) plays a crucial role in maintaining human health, along with its known capacity to prevent and treat various diseases, including cardiovascular diseases, metabolic syndromes, osteoporosis, diabetes, brain-related diseases, high blood pressure, hyperlipidemia, obesity, and inflammation. However, factors affecting individual variations in (S)-EQ production and the underlying regulatory mechanisms remain elusive. This study examines the association between functional genes and (S)-EQ production, highlighting a potential correlation between the DZNR gene and (S)-EQ content. Various types of DZNR may be linked to the regulation of (S)-EQ synthesis. Furthermore, the identification of a new DDRC gene offers promising prospects for enhancing in vitro (S)-EQ production.


Assuntos
Equol , Isoflavonas , Animais , Humanos , Camundongos , Ratos , Suínos , Equol/genética , Equol/metabolismo , Racemases e Epimerases , Galinhas/metabolismo , Isoflavonas/metabolismo , Oxirredutases/metabolismo
5.
Artigo em Inglês | MEDLINE | ID: mdl-38976035

RESUMO

PURPOSE: To explore the feasibility of imaging amino-acid transport and PSMA molecular pathways in the detection of metastatic breast invasive lobular carcinoma (ILC) and if there is superior detection compared to standard-of-care imaging [computed tomography (CT)/bone scan, or 18F-FDG positron-emission-tomography (PET)-CT]. METHODS: 20 women with de-novo or suspected metastatic ILC underwent two PET-CT scans with 18F-fluciclovine and 68Ga-PSMA-11 on separate days. Uptake per patient and in 3 regions per patient - ipsilateral axillary lymph node (LN), extra-axillary LN (ipsilateral supraclavicular or internal mammary), or distant sites of disease - was compared to standard-of-care imaging (CT/bone scan in 13 patients and 18F-FDG PET-CT in 7 patients). Results were correlated to a composite standard of truth. Confirmed detection rate (cDR) was compared using McNemar's test. Mean SUVmax of 18F-fluciclovine and 68Ga-PSMA-11 in the most avid lesion for each true positive metastatic region and intact primary lesion were compared by t-test. RESULTS: The cDR for standard-of-care imaging was 5/20 patients in 5/60 regions. 68Ga-PSMA-11 PET-CT detected metastasis in 7/20 patients in 7/60 regions. 18F-fluciclovine PET-CT detected metastasis in 9/20 patients in 12/60 regions. The cDR for 18F-fluciclovine PET-CT was significantly higher versus standard-of-care imaging on the patient and combined region levels, while there were no significant differences between 68Ga-PSMA-11 and standard-of care imaging. 18F-fluciclovine cDR was also significantly higher than 68Ga-PSMA-11 on the combined region level. Mean SUVmax for true positive metastatic and primary lesions with 18F-fluciclovine (n = 18) was significantly greater than for 68Ga-PSMA-11 (n = 11) [5.5 ± 1.8 versus 3.5 ± 2.7 respectively, p = 0.021]. CONCLUSION: In this exploratory trial, 18F-fluciclovine PET-CT has a significantly higher cDR for ILC metastases compared to standard-of-care imaging and to 68Ga-PSMA-11. Mean SUVmax for true positive malignancy was significantly higher with 18F-fluciclovine than for 68Ga-PSMA-11. Exploratory data from this trial suggests that molecular imaging of amino acid metabolism in patients with ILC deserves further study. CLINICAL TRIAL REGISTRATION: Early phase (I-II) clinical trial (NCT04750473) funded by the National Institutes of Health (R21CA256280).

6.
Gastrointest Endosc ; 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39069266

RESUMO

BACKGROUND AND AIMS: The adenoma detection rate (ADR), recognized as a surrogate marker for colorectal cancer incidence and mortality reduction, is closely linked to the efficacy of bowel cleansing. However, there is a dearth of evidence examining the impact on ADR when employing two distinct very low-dose bowel cleansing products. This study sought to compare ADR in a fecal immunochemical occult blood testing (iFOBT) based organized screening program by utilizing 1L polyethylene glycol plus ascorbate (1L-PEGA) versus magnesium citrate plus picosulphate (SPMC), both administered in a split-dose regimen. METHODS: We conducted a comparative, parallel, randomized, noninferiority, and low-intervention clinical trial, the study targeted individuals from a population colorectal cancer screening program aged 50-69 with a positive iFOBT result scheduled for a work-up colonoscopy in the morning. Participants were randomized to either 1L-PEGA or SPMC for bowel cleansing. Main outcome was ADR. Secondary outcomes were bowel preparation quality, individuals' safety, tolerability and satisfaction. RESULTS: A total of 1,002 subjects were included, 501 in each group. There were no differences between groups with respect to pooled ADR (SPMC, 56.5% [52.1-60.8]; 1L-PEGA, 53.7% [49.3-58.0]; RR 0.95 [0.85-1.06]); therefore, SPMC demonstrated noninferiority in ADR compared to 1L-PEGA (difference, 2.8%; 2-sided 95% lower confidence limit (LCL), -3.4). In addition, there were no significant differences in mean lesions regardless of size and location between arms. Bowel preparation favored 1L-PEGA (96.2% vs. 89.2%; p<0.001) whereas SPMC exhibited significantly higher safety and tolerability, as evidenced by fewer non-serious treatment-emergent adverse events CONCLUSIONS: SPMC emerged as a noninferior laxative compared to 1L-PEGA concerning ADR. Despite the superior bowel preparation quality associated with 1L-PEGA, the safety, tolerability and overall satisfaction of participants were higher with SPMC. This trial was registered at ClinicalTrials.gov (EudraCT: 2019-003186-18) on March 18, 2019.

7.
Scand J Gastroenterol ; 59(8): 882-892, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38775234

RESUMO

BACKGROUND: Adenoma detection rate (ADR) is higher after a positive fecal immunochemical test (FIT) compared to direct screening colonoscopy. OBJECTIVE: This meta-analysis evaluated how ADR, the rates of advanced adenoma detection (AADR), colorectal cancer detection (CDR), and sessile serrated lesion detection (SSLDR) are affected by different FIT positivity thresholds. METHODS: We searched MEDLINE, EMBASE, CINAHL, and EBM Reviews databases for studies reporting ADR, AADR, CDR, and SSLDR according to different FIT cut-off values in asymptomatic average-risk individuals aged 50-74 years old. Data were stratified according to sex, age, time to colonoscopy, publication year, continent, and FIT kit type. Study quality, heterogeneity, and publication bias were assessed. RESULTS: Overall, 4280 articles were retrieved and fifty-eight studies were included (277,661 FIT-positive colonoscopies; mean cecal intubation 96.3%; mean age 60.8 years; male 52.1%). Mean ADR was 56.1% (95% CI 53.4 - 58.7%), while mean AADR, CDR, and SSLDR were 27.2% (95% CI 24.4 - 30.1%), 5.3% (95% CI 4.7 - 6.0%), and 3.0% (95% CI 1.7 - 4.6%), respectively. For each 20 µg Hb/g increase in FIT cut-off level, ADR increased by 1.54% (95% CI 0.52 - 2.56%, p < 0.01), AADR by 3.90% (95% CI 2.76 - 5.05%, p < 0.01) and CDR by 1.46% (95% CI 0.66 - 2.24%, p < 0.01). Many detection rates were greater amongst males and Europeans. CONCLUSIONS: ADRs in FIT-positive colonoscopies are influenced by the adopted FIT positivity threshold, and identified targets, importantly, proved to be higher than most current societal recommendations.


Assuntos
Adenoma , Colonoscopia , Neoplasias Colorretais , Detecção Precoce de Câncer , Sangue Oculto , Humanos , Adenoma/diagnóstico , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos , Fezes/química , Idoso , Pessoa de Meia-Idade , Masculino , Imunoquímica , Feminino
8.
Scand J Gastroenterol ; 59(8): 1002-1009, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38850200

RESUMO

BACKGROUND AND STUDY AIMS: Long-time follow-up of sigmoidoscopy screening trials has shown reduced incidence and mortality of colorectal cancer (CRC), but inadequate bowel cleansing may hamper efficacy. The aim of this study was to assess the impact of bowel cleansing quality in sigmoidoscopy screening. PATIENTS AND METHODS: Individuals 50 to 74 years old who had a screening sigmoidoscopy in a population-based Norwegian, randomized trial between 2012 and 2019, were included in this cross-sectional study. The bowel cleansing quality was categorised as excellent, good, partly poor, or poor. The effect of bowel cleansing quality on adenoma detection rate (ADR) and referral to colonoscopy was evaluated by fitting multivariable logistic regression models. RESULTS: 35,710 individuals were included. The bowel cleansing at sigmoidoscopy was excellent in 20,934 (58.6%) individuals, good in 6580 (18.4%), partly poor in 7097 (19.9%) and poor in 1099 (3.1%). The corresponding ADRs were 17.0%, 16.6%, 14.5%, and 13.0%. Compared to participants with excellent bowel cleansing, those with poor bowel cleansing had an odds ratio for adenoma detection of 0.66 (95% confidence interval 0.55-0.79). We found substantial differences in the assessment of bowel cleansing quality among endoscopists. CONCLUSIONS: Inadequate bowel cleansing reduces the efficacy of sigmoidoscopy screening, by lowering ADR. A validated rating scale and improved bowel preparation are needed to make sigmoidoscopy an appropriate screening method.Trial registration Clinicaltrials.gov (NCT01538550).


Assuntos
Adenoma , Neoplasias Colorretais , Detecção Precoce de Câncer , Sigmoidoscopia , Humanos , Pessoa de Meia-Idade , Feminino , Masculino , Idoso , Neoplasias Colorretais/diagnóstico , Noruega , Estudos Transversais , Detecção Precoce de Câncer/métodos , Adenoma/diagnóstico , Catárticos/administração & dosagem , Colonoscopia/métodos , Modelos Logísticos , Programas de Rastreamento/métodos
9.
BMC Gastroenterol ; 24(1): 132, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609900

RESUMO

BACKGROUND: Different split regimens of polyethylene glycol are routinely used and no guidelines are available to select an optimal protocol of ingestion. This study aims to compare the efficacy and side effect profile of two different regimens of polyethylene glycol bowel preparation solution: PEG (3 + 1) vs. PEG (2 + 2). METHODS: 240 patients above the age of 18 years were included in the study between June 1st and November 31st, 2023. Patients were randomly assigned either to Group A, consisting of 115 patients receiving a 3 L of PEG the night before the colonoscopy, and 1 L the same morning of the procedure. Or to group B, where 125 patients ingested 2 L the night before the procedure, and the remaining 2 L the same morning. The cleansing efficacy was evaluated by the attending endoscopist using the Boston Bowel Preparation Scale, through a score assigned for each segment of the colon (0-3). Side effects, tolerability, and willingness to retake the same preparation were listed by an independent investigator using a questionnaire administered before the procedure. RESULTS: A higher percentage of patients had gastric fullness with the 3 + 1 vs. 2 + 2 preparation (58.3% vs. 31.2%; p <.001). A higher Boston bowel preparation score was seen in patients who took the 2 + 2 vs. 3 + 1 preparation (7.87 vs. 7.23). Using the 2 + 2 preparation was significantly associated with higher Boston bowel preparation scores vs. the 3 + 1 preparation (OR = 1.37, p =.001, 95% CI 1.14, 1.64). After adjustment over other variables (age, gender, comorbidities, previous abdominal surgeries, presence of adenoma, and time between last dose and colonoscopy), results remained the same (aOR = 1.34, p =.003, 95% CI 1.10, 1.62). CONCLUSION: While both (2 + 2) and (3 + 1) regimens of polyethylene glycol are a good choice for a successful colonoscopy, we recommend the use of (2 + 2) regimen for its superior efficacy in bowel cleansing.


Assuntos
Colonoscopia , Polietilenoglicóis , Humanos , Adolescente , Estudos Prospectivos , Protocolos Clínicos , Polietilenoglicóis/efeitos adversos , Estômago
10.
Int J Colorectal Dis ; 39(1): 19, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38227195

RESUMO

BACKGROUND: Adenoma's detection rates have been reported to vary with the participation status of endoscopic nurses during colonoscopy. This meta-analysis was conducted to determine whether the participation of endoscopy nurses during colonoscopy contributed to the improved detection rate of polyps and adenomas. METHODS: We retrieved English original research from PubMed, Embase, Web of Science, and Cochrane library databases and Chinese original research from the CNKI Data database. We searched for randomized controlled trials (RCTs) comparing the effect of participation of endoscopy nurses during colonoscopy of colorectal polyps and adenomas on polyp detection rates to that of nonparticipation. RevMan5.4 software was used to perform the meta-analysis. RESULTS: This meta-analysis included 11 randomized controlled trials involving 8278 patients. The results showed no significant difference between colonoscopies performed by nurses and endoscopists, but colonoscopies performed by two nurses significantly improved the detection rate of polyps and adenomas. In the random effects model, there was a significant difference in PDR between the single-observation and dual-observation groups (RR, 1.27; 95%CI, 1.05, 1.54; Z = 2.51; P = 0.01). The ADR difference between the single observation group and the double observation group was statistically significant (RR, 1.15; 95%CI, 1.05, 1.26; Z = 2.91; P = 0.004). CONCLUSION: Endoscopy nurses' participation in colonoscopy can improve the detection rate of polyps and adenomas, However, more research is needed to confirm the results.


Assuntos
Adenoma , Pólipos , Humanos , Adenoma/diagnóstico , Colonoscopia , Bases de Dados Factuais , Ensaios Clínicos Controlados Aleatórios como Assunto , Enfermeiras e Enfermeiros
11.
Ultrasound Obstet Gynecol ; 63(4): 466-471, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-37743681

RESUMO

OBJECTIVE: To evaluate the new 36-week Fetal Medicine Foundation (FMF) competing-risks model for the prediction of small-for-gestational age (SGA) at an earlier gestation of 30 + 0 to 34 + 0 weeks. METHODS: This was a retrospective multicenter cohort study of prospectively collected data on 3012 women with a singleton pregnancy undergoing ultrasound examination at 30 + 0 to 34 + 0 weeks' gestation as part of a universal screening program. We used the default FMF competing-risks model for prediction of SGA at 36 weeks' gestation combining maternal factors (age, obstetric and medical history, weight, height, smoking status, race, mode of conception), estimated fetal weight (EFW) and uterine artery pulsatility index (UtA-PI) to calculate risks for different cut-offs of birth-weight percentile and gestational age at delivery. We examined the accuracy of the model by means of discrimination and calibration. RESULTS: The prediction of SGA < 3rd percentile improved with the addition of UtA-PI and with a shorter examination-to-delivery interval. For a 10% false-positive rate, maternal factors, EFW and UtA-PI predicted 88.0%, 74.4% and 72.8% of SGA < 3rd percentile delivered at < 37, < 40 and < 42 weeks' gestation, respectively. The respective values for SGA < 10th percentile were 86.1%, 69.3% and 66.2%. In terms of population stratification, if the biomarkers used are EFW and UtA-PI and the aim is to detect 90% of SGA < 10th percentile, then 10.8% of the population should be scanned within 2 weeks after the initial assessment, an additional 7.2% (total screen-positive rate (SPR), 18.0%) should be scanned within 2-4 weeks after the initial assessment and an additional 11.7% (total SPR, 29.7%) should be examined within 4-6 weeks after the initial assessment. The new model was well calibrated. CONCLUSIONS: The 36-week FMF competing-risks model for SGA is also applicable and accurate at 30 + 0 to 34 + 0 weeks and provides effective risk stratification, especially for cases leading to delivery < 37 weeks of gestation. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Perinatologia , Ultrassonografia Pré-Natal , Gravidez , Recém-Nascido , Feminino , Humanos , Lactente , Terceiro Trimestre da Gravidez , Estudos de Coortes , Recém-Nascido Pequeno para a Idade Gestacional , Retardo do Crescimento Fetal/diagnóstico por imagem , Peso Fetal , Idade Gestacional , Artéria Uterina/diagnóstico por imagem , Valor Preditivo dos Testes
12.
J Gastroenterol Hepatol ; 39(4): 694-700, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38200678

RESUMO

BACKGROUND AND AIM: The incidence of colorectal cancer (CRC) in individuals under 50 is increasing worldwide. We conducted an analysis of colonoscopy findings in high-risk individuals under 50 in the CRC screening program in Tianjin, China, to determine the detection rate and risk factors of advanced adenomas (AA), advanced colorectal neoplasia (ACN), colorectal neoplasia (CN). METHODS: Our study investigated individuals aged 40-49 who underwent CRC screening and completed colonoscopy, 2012-2020, while the 50-54 age group served as a control. We compared the detection rates of AA, ACN, and CN among three age groups using univariate and multivariable logistic regression analyses, and investigated the risk factors associated with AA, ACN, and CN among individuals aged 40-49. RESULTS: We found a gradual increase in the detection rate of AA, ACN, and CN among individuals aged 40-54. The detection rates for AA (OR 0.58; 95% CI 0.41-0.81), ACN (OR 0.58; 95% CI 0.43-0.77), and CN (OR 0.64; 95% CI 0.56-0.74) were lower in individuals aged 40-44 compared to 45-49. The detection rates of AA (OR 1.08; 95% CI 0.87-1.34) and ACN (OR 1.12; 95% CI 0.93-1.35) in individuals aged 45-49 were comparable with 50-54. Besides, lifestyle factors, BMI, and FIT are not associated with the detection rates of AA, ACN, and CN among individuals aged 40-49. CONCLUSIONS: Our study reveals screening data in individuals under 50, indicating comparable detection rates of AA and ACN in individuals aged 45-49 and 50-54. These findings provide valuable data support for optimizing the optimal age to initiate screening.


Assuntos
Colonoscopia , Neoplasias Colorretais , Humanos , Pessoa de Meia-Idade , Prevalência , Fatores de Risco , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/epidemiologia , Estilo de Vida , Detecção Precoce de Câncer , Programas de Rastreamento
13.
J Gastroenterol Hepatol ; 39(7): 1374-1381, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38602345

RESUMO

BACKGROUND AND AIM: Linked color imaging (LCI) is an image-enhanced endoscopy technique that accentuates the color difference between red and white, potentially improving the adenoma detection rate (ADR). However, it remains unclear whether LCI performance in detecting colorectal lesions differs based on endoscopists' experience levels. We aimed to evaluate the differences in LCI efficacy based on the experience levels of endoscopists by conducting an exploratory analysis. METHODS: In this post hoc analysis of an international randomized controlled trial comparing the detection of adenoma and other lesions using colonoscopy with LCI and high-definition white light imaging (WLI), we included patients from 11 institutions across four countries/regions: Japan, Thailand, Taiwan, and Singapore. We retrospectively reviewed differences in the lesion detection of LCI according to endoscopists' colonoscopy history or ADR. RESULTS: We included 1692 and 1138 patients who underwent colonoscopies performed by 54 experts (experience of ≥ 5000 colonoscopies) and by 43 non-experts (experience of < 5000 colonoscopies), respectively. Both expert and non-expert groups showed a significant improvement in ADR with LCI compared to WLI (expert, 61.7% vs 46.4%; P < 0.001; non-expert, 56.6% vs 46.4%; P < 0.001). LCI had no effect on sessile serrated lesion detection rate in non-experts (3.1% vs 2.5%; P = 0.518). LCI significantly improved detection rates in endoscopists with relatively low detection performance, defined as an ADR < 50%. CONCLUSIONS: This exploratory study analyzed data from a previous trial and revealed that LCI is useful for both experts and non-experts and is even more beneficial for endoscopists with relatively low detection performance using WLI.


Assuntos
Adenoma , Colonoscopia , Cor , Neoplasias Colorretais , Humanos , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/diagnóstico por imagem , Adenoma/diagnóstico por imagem , Adenoma/diagnóstico , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Competência Clínica , Estudos Retrospectivos , Aumento da Imagem/métodos , Ásia
14.
J Gastroenterol Hepatol ; 39(3): 457-463, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37984841

RESUMO

BACKGROUND AND AIM: The purpose of this randomized controlled study was to compare the characteristics of the CF-H290I (high-definition) colonoscope with those of the PCF-Q260JI (high-resolution) colonoscope in non-sedated patients with a history of abdominal or pelvic surgery in an effort to help endoscopists to select more effectively and objectively between the various colonoscopes. METHODS: A total of 397 patients who underwent colonoscopy at the Affiliated Wuxi People's Hospital of Nanjing Medical University, between August 2022 and October 2022 were randomized to a CF-H290I group (n = 198) or a PCF-Q260JI group (n = 199) using a computer-generated allocation method. We compared the adenoma detection rate (ADR), patient satisfaction with the examination, discomfort associated with colonoscopy including abdominal distension and pain, cecal intubation time, and patient willingness to undergo colonoscopy in the future between the CF-H290I and PCF-Q260JI groups. RESULTS: There was no statistically significant difference in the overall ADR between the CF-H290I and PCF-Q260JI groups (81 [40.9%] vs 63 [31.7%], Z = 3.674, P = 0.055). However, the ADRs in the transverse colon and left colon were significantly higher in the CF-H290I group (22 [11.1%] vs 6 [3.0%], Z = 9.588, P = 0.002 and 57 [28.8%] vs 37 [18.6%], Z = 5.212, P = 0.017, respectively). More sessile serrated lesions were detected in the CF-H290I group (52 [26.3] vs 30 [15.1%], Z = 7.579, P = 0.006). Patient satisfaction with colonoscopy was better in the PCF-Q260JI group (8.91 ± 1.09 vs 8.51 ± 1.44, t = -3.158, P < 0.01) with less likelihood of discomfort (23 [11.6%] vs 41 [20.7%], Z = 6.144, P = 0.013), The number of patients willing to undergo colonoscopy in the future was significantly greater in the PCF-Q260JI group (168 [84.4%] vs 149 [75.3%], Z = 5.186, P = 0.023). The cecal intubation time was significantly shorter in the CF-H290I group (256.09 ± 155.70 s vs 315.64 ± 171.64 s, P = 0.004). There were no complications such as perforation or bleeding in either group. CONCLUSION: The CF-H290I and PCF-Q260JI colonoscopes each have advantages when used in patients with a history of abdominal or pelvic surgery. The CF-H290I has higher ADRs in the transverse and left colon whereas the PCF-Q260JI is less painful and better accepted by patients. This study was approved by the Clinical Research Ethics Committee of Wuxi People's Hospital and was registered in the Chinese Clinical Trial Registry (ChiCTR2200063092).


Assuntos
Adenoma , Colonoscopia , Humanos , Colonoscopia/efeitos adversos , Colonoscopia/métodos , Ceco , Estudos Prospectivos , Desenho de Equipamento , Colonoscópios/efeitos adversos , Dor/etiologia
15.
Dig Dis Sci ; 69(4): 1380-1388, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38436866

RESUMO

BACKGROUND AND AIMS: Screening colonoscopy has significantly contributed to the reduction of the incidence of colorectal cancer (CRC) and its associated mortality, with adenoma detection rate (ADR) as the quality marker. To increase the ADR, various solutions have been proposed including the utilization of Artificial Intelligence (AI) and employing second observers during colonoscopies. In the interest of AI improving ADR independently, without a second observer, and the operational similarity between AI and second observer, this network meta-analysis aims at evaluating the effectiveness of AI, second observer, and a single observer in improving ADR. METHODS: We searched the Medline, Embase, Cochrane, Web of Science Core Collection, Korean Citation Index, SciELO, Global Index Medicus, and Cochrane. A direct head-to-head comparator analysis and network meta-analysis were performed using the random-effects model. The odds ratio (OR) was calculated with a 95% confidence interval (CI) and p-value < 0.05 was considered statistically significant. RESULTS: We analyzed 26 studies, involving 22,560 subjects. In the direct comparative analysis, AI demonstrated higher ADR (OR: 0.668, 95% CI 0.595-0.749, p < 0.001) than single observer. Dual observer demonstrated a higher ADR (OR: 0.771, 95% CI 0.688-0.865, p < 0.001) than single operator. In network meta-analysis, results were consistent on the network meta-analysis, maintaining consistency. No statistical difference was noted when comparing AI to second observer. (RR 1.1 (0.9-1.2, p = 0.3). Results were consistent when evaluating only RCTs. Net ranking provided higher score to AI followed by second observer followed by single observer. CONCLUSION: Artificial Intelligence and second-observer colonoscopy showed superior success in Adenoma Detection Rate when compared to single-observer colonoscopy. Although not statistically significant, net ranking model favors the superiority of AI to the second observer.


Assuntos
Adenoma , Neoplasias Colorretais , Humanos , Inteligência Artificial , Colonoscopia/métodos , Adenoma/diagnóstico , Metanálise em Rede , Razão de Chances , Neoplasias Colorretais/diagnóstico
16.
Dig Endosc ; 36(1): 40-48, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37079002

RESUMO

OBJECTIVE: This study was performed to evaluate whether the use of CAD EYE (Fujifilm, Tokyo, Japan) for colonoscopy improves colonoscopy quality in gastroenterology trainees. METHODS: The patients in this multicenter randomized controlled trial were divided into Group A (observation using CAD EYE) and Group B (standard observation). Six trainees performed colonoscopies using a back-to-back method in pairs with gastroenterology experts. The primary end-point was the trainees' adenoma detection rate (ADR), and the secondary end-points were the trainees' adenoma miss rate (AMR) and Assessment of Competency in Endoscopy (ACE) tool scores. Each trainee's learning curve was evaluated using a cumulative sum (CUSUM) control chart. RESULTS: We analyzed data for 231 patients (Group A, n = 113; Group B, n = 118). The ADR was not significantly different between the two groups. Group A had a significantly lower AMR (25.6% vs. 38.6%, P = 0.033) and number of missed adenomas per patient (0.5 vs. 0.9, P = 0.004) than Group B. Group A also had significantly higher ACE tool scores for pathology identification (2.26 vs. 2.07, P = 0.030) and interpretation and identification of pathology location (2.18 vs. 2.00, P = 0.038). For the CUSUM learning curve, Group A showed a trend toward a lower number of cases of missed multiple adenomas by the six trainees. CONCLUSION: CAD EYE did not improve ADR but decreased the AMR and improved the ability to accurately locate and identify colorectal adenomas. CAD EYE can be assumed to be beneficial for improving colonoscopy quality in gastroenterology trainees. TRIAL REGISTRATION: University Hospital Medical Information Network Clinical Trials Registry (UMIN000044031).


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Humanos , Inteligência Artificial , Estudos Prospectivos , Competência Clínica , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Adenoma/diagnóstico , Adenoma/patologia , Pólipos do Colo/diagnóstico
17.
Sensors (Basel) ; 24(7)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38610399

RESUMO

The Internet of Things (IoT) is the underlying technology that has enabled connecting daily apparatus to the Internet and enjoying the facilities of smart services. IoT marketing is experiencing an impressive 16.7% growth rate and is a nearly USD 300.3 billion market. These eye-catching figures have made it an attractive playground for cybercriminals. IoT devices are built using resource-constrained architecture to offer compact sizes and competitive prices. As a result, integrating sophisticated cybersecurity features is beyond the scope of the computational capabilities of IoT. All of these have contributed to a surge in IoT intrusion. This paper presents an LSTM-based Intrusion Detection System (IDS) with a Dynamic Access Control (DAC) algorithm that not only detects but also defends against intrusion. This novel approach has achieved an impressive 97.16% validation accuracy. Unlike most of the IDSs, the model of the proposed IDS has been selected and optimized through mathematical analysis. Additionally, it boasts the ability to identify a wider range of threats (14 to be exact) compared to other IDS solutions, translating to enhanced security. Furthermore, it has been fine-tuned to strike a balance between accurately flagging threats and minimizing false alarms. Its impressive performance metrics (precision, recall, and F1 score all hovering around 97%) showcase the potential of this innovative IDS to elevate IoT security. The proposed IDS boasts an impressive detection rate, exceeding 98%. This high accuracy instills confidence in its reliability. Furthermore, its lightning-fast response time, averaging under 1.2 s, positions it among the fastest intrusion detection systems available.

18.
Nano Lett ; 23(13): 6018-6026, 2023 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-37352368

RESUMO

Superconducting nanowire single-photon detectors (SNSPDs) have enabled the realization of several quantum optics technologies thanks to their high system detection efficiency (SDE), low dark counts, and fast recovery time. However, the widespread use of linear optical quantum computing, quasi-deterministic single-photon sources, and quantum repeaters requires even faster detectors that can also distinguish between different photon-number states. Here, we present an SNSPD array composed of 14 independent pixels, achieving an SDE of 90% in the telecommunications band. By reading each pixel of the array independently, we show detection of telecommunication photons at 1.5 GHz with 45% absolute SDE. We exploit the dynamic photon-number resolution of the array to demonstrate accurate state reconstruction for a wide range of light inputs, including operation with long-duration light pulses, as obtained with some cavity-based sources. We show two-photon and three-photon fidelities of 74% and 57%, respectively, which represent state-of-the-art results for fiber-coupled SNSPDs.

19.
Medicina (Kaunas) ; 60(7)2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39064595

RESUMO

Background and Objectives: The implementation and monitoring of the European Society of Gastrointestinal Endoscopy (ESGE) performance measures for colonoscopy are suboptimal in clinical practice. Electronic reporting systems may play an important role in data retrieval. We aimed to define the possibility of systematically assessing and monitoring ESGE performance measures for colonoscopy through reporting systems. Materials and Methods: We conducted a survey during a nationwide event on the quality of colonoscopy held in Rome, Italy, in March 2023 by a self-administered questionnaire. Analyses were conducted overall and by workplace setting. Results: The attendance was 93% (M/F 67/26), with equal distribution of age groups, regions and public or private practices. Only about one-third (34%) and 21.5% of participants stated that their reporting system allows them to retrieve all the ESGE performance measures, overall and as automatic retrieval, respectively. Only 66.7% and 10.7% of respondents can systematically report the cecal intubation and the adenoma detection rate, respectively. The analysis according to hospital setting revealed no significant difference for all the items. Conclusions: We found a generalized lack of systematic tracking of performance measures for colonoscopy due to underperforming reporting systems. Our results underline the need to update reporting systems to monitor the quality of endoscopy practice in Italy.


Assuntos
Colonoscopia , Humanos , Colonoscopia/normas , Colonoscopia/estatística & dados numéricos , Inquéritos e Questionários , Masculino , Feminino , Pessoa de Meia-Idade , Itália , Adulto , Idoso , Endoscopia Gastrointestinal/normas , Endoscopia Gastrointestinal/estatística & dados numéricos , Sociedades Médicas , Europa (Continente)
20.
Int J Cancer ; 152(6): 1085-1094, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36178673

RESUMO

Serrated polyps (SPs) are precursors to one-third of colorectal cancers (CRCs), with histological subtypes: hyperplastic polyps (HPs), sessile serrated lesions (SSLs) and traditional serrated adenomas (TSAs). The incidence of early-onset CRC before the age of 50 is increasing, with limited understanding of SPs in younger cohorts. Using a large colonoscopy-based cohort, we characterized epidemiologic profiles of SP subtypes, compared to conventional adenomas, with secondary analysis on early-onset polyps. Ninety-four thousand four hundred and twenty-seven patients underwent screening colonoscopies between 2010 and 2018. Demographic, endoscopic and histopathologic characteristics of each polyp subtype were described. High-risk polyps included SSLs ≥10 mm/with dysplasia and conventional adenomas ≥10 mm/with tubulovillous/villous histology/high-grade dysplasia. We examined polyp prevalence with age and compared early- (age < 50) and late-onset polyps (age ≥ 50). Eighteen thousand one hundred and twenty-five patients had SPs (4357 SSLs, 15 415 HPs, 120 TSAs) and 26 699 had conventional adenomas. High-risk SSLs were enriched in the ascending colon (44.1% vs 2.6-35.8% for other locations; P < .003). Early- and late-onset SPs had similar subsite distribution. Early-onset conventional adenomas were more enriched in the distal colon/rectum (51.8% vs 43.4%, P < .001). Multiple conventional adenomas were more represented in late-onset groups (40.8% vs 33.8%, P < .001), with no difference in SSLs. The prevalence of conventional adenomas/high-risk conventional adenomas increased continuously with age, whereas the prevalence of SSLs/high-risk SSLs was stable from age 40 years onwards. A higher proportion of women were diagnosed with early-onset than late-onset SSLs (62.9% vs 57.6%, P = .03). Conventional adenomas, SSLs, early- and late-onset polyps have distinct epidemiology. The findings have implications for improved colonoscopy screening and surveillance and understanding the etiologic heterogeneity of CRC.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Humanos , Feminino , Adulto , Pólipos do Colo/diagnóstico , Pólipos do Colo/epidemiologia , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/epidemiologia , Neoplasias Colorretais/patologia , Colonoscopia , Adenoma/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA