1.
J Sleep Res ; 31(6): e13555, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35124848

RESUMO

Acoustic stimulation synchronized to slow oscillations in scalp electroencephalograms has been shown to enhance sleep features, which makes it promising in boosting cognitive functions as well as in the treatment of some sleep disturbances. Nevertheless, scalp electrode sensors are resource intensive and poorly tolerated by sleeping patients. The aim of this study was to investigate the potential usability of in-the-ear electroencephalography to implement auditory closed-loop stimulation during sleep. For this, we evaluated the agreement between slow oscillation recordings obtained through the in-ear sensor and those obtained simultaneously from standard scalp electrodes during naps of 13 healthy subjects. We found that in-ear activity provided enough information to automatically detect sleep slow oscillations in real-time. Based on this, we successfully enhanced scalp slow oscillations using auditory single-cycle closed-loop brain-state-dependent stimulation based on in-ear signals acquired in 11 further subjects. We conclude that in-ear sensors provide a feasible technology for the enhancement of sleep patterns, and could pave the way for new clinical applications in the near future.


Assuntos
Eletroencefalografia , Sono , Humanos , Estimulação Acústica , Sono/fisiologia , Encéfalo/fisiologia , Couro Cabeludo
2.
J Med Syst ; 46(12): 91, 2022 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-36329338

RESUMO

In the context of the COVID-19 pandemic, wearable sensors are important for early detection of critical illness especially in COVID-19 outpatients. We sought to determine in this pilot study whether a wearable in-ear sensor for continuous body temperature and heart rate monitoring (Cosinuss company, Munich) is sufficiently accurate for body temperature and heart rate monitoring. Comparing with several anesthesiologic standard of care monitoring devices (urinary bladder and zero-heat flux thermometer and ECG), we evaluated the in-ear sensor during non-cardiac surgery (German Clinical Trials Register Reg.-No: DRKS00012848). Limits of Agreement (LoA) based on Bland-Altman analysis were used to study the agreement between the in-ear sensor and the reference methods. The estimated LoA of the Cosinuss One and bladder temperature monitoring were [-0.79, 0.49] °C (95% confidence intervals [-1.03, -0.65] (lower LoA) and [0.35, 0.73] (upper LoA)), and [-0.78, 0.34] °C (95% confidence intervals [-1.18, -0.59] (lower LoA) and [0.16, 0.74] (upper LoA)) of the Cosinuss One and zero-heat flux temperature monitoring. 89% and 79% of Cosinuss One temperature monitoring were within ± 0.5 °C limit of bladder and zero-heat flux monitoring, respectively. The estimated LoA of Cosinuss One and ECG heart rate monitoring were [-4.81, 4.27] BPM (95% confidence intervals [-5.09, -4.56] (lower LoA) and [4.01, 4.54] (upper LoA)). The proportion of detection differences within ± 2BPM was 84%. Body temperature and heart rate were reliably measured by the wearable in-ear sensor.


Assuntos
COVID-19 , Dispositivos Eletrônicos Vestíveis , Humanos , Temperatura , Projetos Piloto , Frequência Cardíaca/fisiologia , Pandemias , COVID-19/diagnóstico , Temperatura Corporal/fisiologia
3.
Sensors (Basel) ; 19(15)2019 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-31390830

RESUMO

We intend to develop earphone-type wearable devices to measure occlusal force by measuring ear canal movement using an ear sensor that we developed. The proposed device can measure occlusal force during eating. In this work, we simultaneously measured the ear canal movement (ear sensor value), the surface electromyography (EMG) of the masseter muscle and the occlusal force six times from five subjects as a basic study toward occlusal force meter development. Using the results, we investigated the correlation coefficient between the ear sensor value and the occlusal force, and the partial correlation coefficient between ear sensor values. Additionally, we investigated the average of the partial correlation coefficient and the absolute value of the average for each subject. The absolute value results indicated strong correlation, with correlation coefficients exceeding 0.9514 for all subjects. The subjects showed a lowest partial correlation coefficient of 0.6161 and a highest value of 0.8286. This was also indicative of correlation. We then estimated the occlusal force via a single regression analysis for each subject. Evaluation of the proposed method via the cross-validation method indicated that the root-mean-square error when comparing actual values with estimates for the five subjects ranged from 0.0338 to 0.0969.


Assuntos
Meato Acústico Externo/fisiologia , Eletromiografia/métodos , Potenciais de Ação , Adulto , Força de Mordida , Feminino , Humanos , Masculino , Músculo Masseter/fisiologia , Movimento , Dispositivos Eletrônicos Vestíveis , Adulto Jovem
4.
Sensors (Basel) ; 18(1)2018 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-29320395

RESUMO

The aim of the present study was to automatically predict the onset of farrowing in crate-confined sows. (1) Background: Automatic tools are appropriate to support animal surveillance under practical farming conditions. (2) Methods: In three batches, sows in one farrowing compartment of the Futterkamp research farm were equipped with an ear sensor to sample acceleration. As a reference video, recordings of the sows were used. A classical CUSUM chart using different acceleration indices of various distribution characteristics with several scenarios were compared. (3) Results: The increase of activity mainly due to nest building behavior before the onset of farrowing could be detected with the sow individual CUSUM chart. The best performance required a statistical distribution characteristic that represented fluctuations in the signal (for example, 1st variation) combined with a transformation of this parameter by cumulating differences in the signal within certain time periods from one day to another. With this transformed signal, farrowing sows could reliably be detected. For 100% or 85% of the sows, an alarm was given within 48 or 12 h before the onset of farrowing. (4) Conclusions: Acceleration measurements in the ear of a sow are suitable for detecting the onset of farrowing in individually housed sows in commercial farrowing crates.


Assuntos
Aceleração , Animais , Comportamento Animal , Feminino , Suínos
5.
Sensors (Basel) ; 18(9)2018 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-30201861

RESUMO

We have carried out research and development on an earphone-type respiratory rate measuring device, earable POCER. The name earable POCER is a combination of "earable", which is a word coined from "wearable" and "ear", and "POCER", which is an acronym for "point-of-care ear sensor for respiratory rate measurement". The earable POCER calculates respiratory frequency, based on the measurement values over one minute, through the simple attachment of an ear sensor to one ear of the measured subject and displays these on a tablet terminal. The earable POCER irradiates infrared light using a light-emitting diode (LED) loaded on an ear sensor to the epidermis within the ear canal and, by receiving that reflected light with a phototransistor, it measures movement of the ear canal based on respiration. In an evaluation experiment, eight healthy subjects first breathed through the nose 12 times per minute, then 16 times per minute, and finally 20 times per minute, in accordance with the flashing of a timing instruction LED. The results of these evaluation tests showed that the accuracy of the respiratory frequency was 100% for nose breathing 12 times per minute, 93.8% at 16 times, and 93.8% at 20 times.


Assuntos
Meato Acústico Externo/fisiologia , Movimento , Sistemas Automatizados de Assistência Junto ao Leito , Taxa Respiratória/fisiologia , Dispositivos Eletrônicos Vestíveis , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS