Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(4): 737-746, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38355929

RESUMO

INTRODUCTION: Luminal esophageal temperature (LET) monitoring during atrial fibrillation (AF) ablation is widely used to reduce the incidence of endoscopically detected esophageal lesion (EDEL). We sought to assess whether specific patterns of LET variation are associated with EDEL. METHODS: A high-fidelity multisensor probe was used to record LET in AF patients undergoing radiofrequency ablation (RFA) or cryoballoon ablation (CBA). Explainable machine learning and SHapley Additive exPlanations (SHAP) analysis were used to predict EDEL and assess feature importance. RESULTS: A total of 94 patients (38.3% persistent AF, 71.3% male, 72 RFA, and 22 CBA) were included. EDEL was detected in 11 patients (10 RFA and one CBA). In the RFA group, the highest LET recorded was similar between patients with and without EDEL (40.6 [40.1-41]°C vs. 40.2 [39.1-40.9]°C; p = .313), however, the rate of LET rise for the highest recorded peak was higher (0.08 [0.03-0.12]°C/s vs. 0.02 [0.01-0.05]°C/s; p = .033), and the area under the curve (AUC) for the highest peak was smaller (412.5 [206.8-634.1] vs. 588.6 [380.4-861.1]; p = .047) in patients who had EDEL. In case of CBA, the patient with EDEL had a faster LET decline (0.12 vs. 0.07 [0.02-0.14]°C/s), and a smaller AUC for the lowest trough (2491.3 vs. 2629.3 [1712.6-5283.2]). SHAP analysis revealed that a rate of LET change higher than 0.05°C/s and an AUC less than 600 were more predictive of EDEL in RFA. CONCLUSION: The rate of LET change and AUC for the recorded temperature predicted EDEL, whereas absolute peak temperatures did not.


Assuntos
Fibrilação Atrial , Queimaduras , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Esofagoscopia , Temperatura , Esôfago/lesões , Ablação por Cateter/efeitos adversos , Queimaduras/epidemiologia , Veias Pulmonares/cirurgia
2.
J Cardiovasc Electrophysiol ; 34(1): 82-89, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36321661

RESUMO

INTRODUCTION: Aim of this study was to evaluate the incidence of ablation-induced endoscopically detected esophageal lesions (EDEL) and gastroparesis in patients undergoing high-power short-duration (HPSD) atrial fibrillation (AF) ablation using different target ablation index (AI) values. METHODS AND RESULTS: Consecutive patients undergoing AF ablation were included. Radiofrequency (RF) ablation was performed using HPSD ablation (50 W, target AI of 320 and 350 (group 1) and 380 (group 2) at posterior wall). Postablation endoscopy was performed in all patients. In total, 233 patients (66.8 ± 10 years; 52% male) were included consecutively (n = 137 patients in group 1 and n = 96 patients in group 2). Mean AI values und RF time at posterior wall was significantly higher and longer in group 2 compared to group 1 patients (413 ± 9 vs. 392 ± 19 AI, p < 0.01; 9.0 ± 0.8 s vs. 7.8 ± 0.7 s, p < 0.01). Esophageal endoscopy revealed esophageal lesions or gastroparesis in 43 of 233 patients (18.5%) in the total cohort (13.1% in group 1 and 26.0% in group 2; p = 0.02). Incidence of EDEL was 8.0% and 13.5% in group 1 and group 2, respectively. According to logistic analysis incidence of EDEL and/or gastroparesis was significantly lower in patients with a higher body mass index and higher in group 2 patients compared to group 1 patients. CONCLUSION: The incidence of EDEL or gastroparesis in patients undergoing HPSD AF ablation was 18.5% in the total cohort. The risk of EDEL and gastroparesis was associated with a higher AI target value of 380 compared to 320 and 350 at posterior wall and was reversely associated with body mass index.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Gastroparesia , Veias Pulmonares , Humanos , Masculino , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Incidência , Gastroparesia/diagnóstico , Gastroparesia/epidemiologia , Gastroparesia/etiologia , Esôfago/diagnóstico por imagem , Esôfago/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Resultado do Tratamento
3.
J Cardiovasc Electrophysiol ; 33(12): 2504-2513, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36124396

RESUMO

BACKGROUND: This study sought to evaluate the short and midterm efficacy and safety of the novel very high power very short duration (vHPvSD) 90 W approach compared to HPSD 50 W for atrial fibrillation (AF) ablation as well as reconnection patterns of 90 W ablations. METHODS AND RESULTS: Consecutive patients undergoing first AF ablation with vHPvSD (90 W; predefined ablation time of 3 s for posterior wall ablation and 4 s for anterior wall ablation) were compared to patients using HPSD (50 W; ablation index-guided; AI 350 for posterior wall ablation, AI 450 for anterior wall ablation) retrospectively. A total of 84 patients (67.1 ± 9.8 years; 58% male; 47% paroxysmal AF) were included (42 with 90 W, 42 with 50 W) out of a propensity score-matched cohort. 90 W ablations revealed shorter ablation times (10.5 ± 6.7 min vs. 17.4 ± 9.9 min; p = .001). No major complication occurred. 90 W ablations revealed lower first pass PVI rates (40% vs. 62%; p = .049) and higher AF recurrences during blanking period (38% vs. 12%; p = .007). After 12 months, both ablation approaches revealed comparable midterm outcomes (62% vs. 70%; log-rank p = .452). In a multivariable Cox regression model, persistent AF (hazard ratio [HR]: 1.442, 95% confidence interval [CI]: 1.035-2.010, p = .031) and increased procedural duration (HR: 1.011, 95% CI: 1.005-1.017, p = .001) were identified as independent predictors of AF recurrence during follow-up. CONCLUSIONS: AF ablation using 90 W vHPvSD reveals a similar safety profile compared to 50 W ablation with shorter ablation times. However, vHPvSD ablation was associated with lower rates of first-pass isolations and increased AF recurrences during the blanking period. After 12 months, 90 W revealed comparable efficacy results to 50 W ablations in a nonrandomized, propensity-matched comparison.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Recidiva , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
4.
J Cardiovasc Electrophysiol ; 33(5): 920-927, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35233883

RESUMO

INTRODUCTION: High power short duration (HPSD) ablation proved to be an effective and safe ablation technique for atrial fibrillation (AF). In former case series, a significant amount of postablation coagulation at the catheter tip as well as silent cerebral lesions (SCL) in postprocedural cerebral magnetic resonance (cMRI) have been identified in patients undergoing de-novo AF ablations with very high power 90 W short duration (vHPvSD) ablations using the QDot ablation catheter in combination with a novel RF generator (nGEN, Biosense Webster). Therefore, the RF generator software has been recently modified. METHODS AND RESULTS: Consecutive patients undergoing a first AF ablation including pulmonary vein isolation (PVI) with vHPvSD (90 W, with a predefined ablation time of 3 s at posterior left atrium (LA) wall sites and 4 s at other ablation sites) using the QDOT Micro ablation catheter (Biosense Webster) in conjunction with the technically modified nGEN RF generator (software V1c; Biosense Webster) were included. Procedural characteristics including first-pass isolation per pulmonary vein (PV) pair and early reconnection location within the 30-min waiting period were recorded. In all patients postablation endoscopy to document any thermal esophageal injury (EDEL) and in eligible patients a cMRI to detect silent cerebral events (SCEs)/lesions were performed. All acute procedure-related complications were recorded during the time until hospital discharge. Furthermore, short-term and midterm success after 3 and 6-12 months of follow-up was investigated. In total, 34 consecutive patients (67 ± 9 years; 62% male; 68% paroxysmal AF) were included. First-pass isolation of all PVs was achieved in 6/34 (18%) patients. First-pass isolation was seen in 37/68 (54%) of PV pairs. Early reconnection occurred in 11 (32%) patients (including reconnections at posterior LA wall sites n = 6 and at nonposterior sites n = 5). No patient had an EDEL (0%). In 6/23 (26%) patients undergoing postablation cerebral MRI SCEs were identified. In six patients, coagulation on the catheter tip was detected at the end of the procedure. No further peri- or postprocedural complications were detected. Early AF recurrence before discharge was seen in 1/34 (3%) of the patients included in this study. Within 3 months 10/34 (29%) revealed AF recurrence during blanking period. After a mean follow-up of 7 months, 31/34 (88%) patients revealed sinus rhythm. CONCLUSION: AF ablation using 90 W vHPvSD with a specialized ablation catheter in conjunction with a recently modified RF generator was associated with no EDEL in the whole study cohort and 26% SCEs in a subgroup of patients undergoing acute postablation cerebral MRI. Accordingly, to our previously published results, a relevant number of catheter tip coagulations was identified in this patient cohort even after modifications of the RF generator. The vHPvSD ablation technique using the present and the previous generator seems to be associated with a very low rate of esophageal injury. However, the recently revised generator software also produced a relevant number of catheter tip coagulum formation and SCEs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Esôfago , Feminino , Humanos , Masculino , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 33(11): 2276-2284, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35979645

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) using high-power-short-duration (HPSD) radiofrequency ablation (RF) is emerging as the standard of care for treatment of atrial fibrillation (AF). While procedural short-term to midterm efficacy and efficiency are very promising, this registry aims to investigate esopahgeal safety using an optimized ablation approach. METHODS: In a single-center experience, 388 consecutive standardized first-time AF ablation were performed using a CLOSE-guided-fixed-50 W-circumferential PVI and substrate modification without intraprocedural esophageal temperature measurement. Three hundred patients underwent postprocedural esophageal endoscopy to diagnose and grade endoscopically detected esophageal lesions (EDEL) and were included in the analysis. RESULTS: EDEL were detected in 35 of 300 patients (11.6%), 25 of 35 were low-grade Kansas-city-classification (KCC) 1 lesions with fast healing tendencies. Six patients suffered KCC 2a lesions, 4 patients had KCC 2b lesions (1.3% of all patients). No esophageal perforation or fistula formation was observed. Patient baseline characteristics, especially patients age, gender, and body mass index did not influence EDEL incidence. Additional posterior box isolation did not increase the incidence of EDEL. In patients diagnosed with EDEL, mean catheter contact force during posterior wall ablation was higher (11.9 ± 1.8 vs. 14.7 ± 3 g, p < .001), mean RF duration was shorter (11.9 ± 1 vs. 10.7 ± 1.2 s, p < .001), while achieved ablation index was not different between groups (434 ± 4.9 vs. 433 ± 9.5, n.s.). CONCLUSION: Incidence of EDEL after CLOSE-guided-50 W-HPSD PVI is lower compared to historical cohorts using standard-power RF settings. Catheter contact force during posterior HPSD ablation should not exceed 15 g.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Fatores de Risco , Ablação por Cateter/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Sistema de Registros , Resultado do Tratamento , Recidiva
6.
J Cardiovasc Electrophysiol ; 32(3): 695-703, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33442930

RESUMO

INTRODUCTION: To evaluate short-term efficacy and incidence of ablation-induced endoscopically detected esophageal injury in patients undergoing high-power, short-duration (HPSD) pulmonary vein isolation using a novel irrigated radiofrequency ablation catheter and ablation generator setup. METHODS AND RESULTS: Atrial fibrillation (AF) patients, who underwent AF ablation using an irrigated radiofrequency ablation catheter specifically designed for a HPSD ablation approach (50 W, with a target Ablation Index of 350 at posterior wall), received postablation esophageal endoscopy after ablation. In total 45 consecutive patients (67 ± 10 years; 58% male; 42% paroxysmal AF) undergoing AF ablation using a specialized ablation catheter (QDOT) were included in the study. Thirty-one of 45 patients (69%) underwent a first-time pulmonary vein isolation (Group 1, 67 ± 11 years; 55% male; 48% paroxysmal AF). Fourteen patients (31%) underwent a redo AF procedure (Group 2, 66 ± 8 years; 64% male; 29% paroxysmal AF). Patients undergoing first-time pulmonary vein isolation were included in the final analysis. In these patients an endoscopically detected esophageal lesion (EDEL) was detected in 5 of 31 (16%) patients (erosion n = 2, ulcer n = 3). Mean contact force at posterior wall ablation sites was significantly lower in patients with postprocedural EDEL compared with patients without EDEL (11.9 ± 0.8 g vs. 15.6 ± 4.7 g). CONCLUSION: PVI using a specialized high-power ablation catheter in conjunction with a HPSD ablation approach results in a 16% incidence of EDEL in first AF ablation candidates. Future studies evaluating high-power short duration ablation strategies should include esophageal endoscopy to estimate the risk of clinically relevant esophageal complications.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres/efeitos adversos , Feminino , Humanos , Incidência , Masculino , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Temperatura , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA