Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.662
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Methods ; 225: 74-88, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38493931

RESUMO

Computational modeling and simulation (CM&S) is a key tool in medical device design, development, and regulatory approval. For example, finite element analysis (FEA) is widely used to understand the mechanical integrity and durability of orthopaedic implants. The ASME V&V 40 standard and supporting FDA guidance provide a framework for establishing model credibility, enabling deeper reliance on CM&S throughout the total product lifecycle. Examples of how to apply the principles outlined in the ASME V&V 40 standard are important to facilitating greater adoption by the medical device community, but few published examples are available that demonstrate best practices. Therefore, this paper outlines an end-to-end (E2E) example of the ASME V&V 40 standard applied to an orthopaedic implant. The objective of this study was to illustrate how to establish the credibility of a computational model intended for use as part of regulatory evaluation. In particular, this study focused on whether a design change to a spinal pedicle screw construct (specifically, the addition of a cannulation to an existing non-cannulated pedicle screw) would compromise the rod-screw construct mechanical performance. This question of interest (?OI) was addressed by establishing model credibility requirements according to the ASME V&V 40 standard. Experimental testing to support model validation was performed using spinal rods and non-cannulated pedicle screw constructs made with medical grade titanium (Ti-6Al-4V ELI). FEA replicating the experimental tests was performed by three independent modelers and validated through comparisons of common mechanical properties such as stiffness and yield force. The validated model was then used to simulate F1717 compression-bending testing on the new cannulated pedicle screw design to answer the ?OI, without performing any additional experimental testing. This E2E example provides a realistic scenario for the application of the ASME V&V 40 standard to orthopedic medical device applications.


Assuntos
Análise de Elementos Finitos , Parafusos Pediculares , Parafusos Pediculares/normas , Humanos , Simulação por Computador , Teste de Materiais/métodos , Teste de Materiais/normas , Titânio/química , Força Compressiva
2.
Small ; : e2400763, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38864211

RESUMO

The Cs3Bi2I9 single crystal, as an all-inorganic non-lead perovskite, offers advantages such as stability and environmental friendliness. Its superior photoelectric properties, attributed to the absence of grain boundary influence, make it an outstanding X-ray detection material compared to polycrystals. In addition to material properties, X-ray detector performance is affected by the thickness of the absorption layer. Addressing this, a space-confined method is proposed. The temperature field is determined through finite element simulation, effectively guiding the design of the space-confined method. Through this innovative method, a series of thickness-controlled perovskite single crystal wafers (PSCWs) are successfully prepared. Corresponding X-ray detectors are then prepared, and the impact of single crystal thickness on device performance is investigated. With an increase in single crystal thickness, a rise followed by a decline in device sensitivity is observed, reaching an optimal value at 0.7 mm thickness at 40V mm-1 with a device performance of 11313.6µC Gy-1 cm-2. This space-confined method enables the direct growth of high-quality perovskite single crystals with specified thickness, eliminating the need for slicing or etching.

3.
Proc Biol Sci ; 291(2025): 20240654, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38889789

RESUMO

The morphology and biomechanics of infant crania undergo significant changes between the pre- and post-weaning phases due to increasing loading of the masticatory system. The aims of this study were to characterize the changes in muscle forces, bite forces and the pattern of mechanical strain and stress arising from the aforementioned forces across crania in the first 48 months of life using imaging and finite element methods. A total of 51 head computed tomography scans of normal individuals were collected and analysed from a larger database of 217 individuals. The estimated mean muscle forces of temporalis, masseter and medial pterygoid increase from 30.9 to 87.0 N, 25.6 to 69.6 N and 23.1 to 58.9 N, respectively (0-48 months). Maximum bite force increases from 90.5 to 184.2 N (3-48 months). There is a change in the pattern of strain and stress from the calvaria to the face during postnatal development. Overall, this study highlights the changes in the mechanics of the craniofacial system during normal development. It further raises questions as to how and what level of changes in the mechanical forces during the development can alter the morphology of the craniofacial system.


Assuntos
Força de Mordida , Crânio , Lactente , Humanos , Fenômenos Biomecânicos , Crânio/anatomia & histologia , Pré-Escolar , Tomografia Computadorizada por Raios X , Análise de Elementos Finitos , Feminino , Masculino , Mastigação , Adaptação Fisiológica , Recém-Nascido , Estresse Mecânico , Músculos da Mastigação/fisiologia
4.
Osteoporos Int ; 35(6): 971-996, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38353706

RESUMO

The use of opportunistic computed tomography (CT) image-based biomarkers may be a low-cost strategy for screening older individuals at high risk for osteoporotic fractures and populations that are not sufficiently targeted. This review aimed to assess the discriminative ability of image-based biomarkers derived from existing clinical routine CT scans for hip, vertebral, and major osteoporotic fracture prediction. A systematic search in PubMed MEDLINE, Embase, Cochrane, and Web of Science was conducted from the earliest indexing date until July 2023. The evaluation of study quality was carried out using a modified Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS-2) checklist. The primary outcome of interest was the area under the curve (AUC) and its corresponding 95% confidence intervals (CIs) obtained for four main categories of biomarkers: areal bone mineral density (BMD), image attenuation, volumetric BMD, and finite element (FE)-derived biomarkers. The meta-analyses were performed using random effects models. Sixty-one studies were included in this review, among which 35 were synthesized in a meta-analysis and the remaining articles were qualitatively synthesized. In comparison to the pooled AUC of areal BMD (0.73 [95% CI 0.71-0.75]), the pooled AUC values for predicting osteoporotic fractures for FE-derived parameters (0.77 [95% CI 0.72-0.81]; p < 0.01) and volumetric BMD (0.76 [95% CI 0.71-0.81]; p < 0.01) were significantly higher, but there was no significant difference with the pooled AUC for image attenuation (0.73 [95% CI 0.66-0.79]; p = 0.93). Compared to areal BMD, volumetric BMD and FE-derived parameters may provide a significant improvement in the discrimination of osteoporotic fractures using opportunistic CT assessments.


Assuntos
Biomarcadores , Densidade Óssea , Fraturas por Osteoporose , Tomografia Computadorizada por Raios X , Humanos , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/fisiopatologia , Densidade Óssea/fisiologia , Tomografia Computadorizada por Raios X/métodos , Biomarcadores/sangue , Programas de Rastreamento/métodos , Fraturas da Coluna Vertebral/fisiopatologia , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/fisiopatologia , Análise de Elementos Finitos
5.
Osteoporos Int ; 35(5): 785-794, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38246971

RESUMO

Hip fracture risk assessment is an important but challenging task. Quantitative CT-based patient-specific finite element (FE) analysis (FEA) incorporates bone geometry and bone density in the proximal femur. We developed a global FEA-computed fracture risk index to increase the prediction accuracy of hip fracture incidence. PURPOSE: Quantitative CT-based patient-specific finite element (FE) analysis (FEA) incorporates bone geometry and bone density in the proximal femur to compute the force (fracture load) and energy necessary to break the proximal femur in a particular loading condition. The fracture loads and energies-to-failure are individually associated with incident hip fracture, and provide different structural information about the proximal femur. METHODS: We used principal component analysis (PCA) to develop a global FEA-computed fracture risk index that incorporates the FEA-computed yield and ultimate failure loads and energies-to-failure in four loading conditions of 110 hip fracture subjects and 235 age- and sex-matched control subjects from the AGES-Reykjavik study. Using a logistic regression model, we compared the prediction performance for hip fracture based on the stratified resampling. RESULTS: We referred the first principal component (PC1) of the FE parameters as the global FEA-computed fracture risk index, which was the significant predictor of hip fracture (p-value < 0.001). The area under the receiver operating characteristic curve (AUC) using PC1 (0.776) was higher than that using all FE parameters combined (0.737) in the males (p-value < 0.001). CONCLUSIONS: The global FEA-computed fracture risk index increased hip fracture risk prediction accuracy in males.


Assuntos
Fraturas do Quadril , Fraturas Proximais do Fêmur , Masculino , Humanos , Fraturas do Quadril/epidemiologia , Fraturas do Quadril/etiologia , Densidade Óssea , Fêmur/diagnóstico por imagem , Curva ROC , Análise de Elementos Finitos
6.
J Theor Biol ; 592: 111893, 2024 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-38944380

RESUMO

The mechanisms underlying the formation of necrotic regions within avascular tumors are complex and poorly understood. In this paper, we investigate the formation of a necrotic core in a 3D tumor cell culture within a microfluidic device, considering oxygen, nutrients, and the microenvironment acidification by means of a computational-mathematical model. Our objective is to simulate cell processes, including proliferation and death inside a microfluidic device, according to the microenvironmental conditions. We employed approximation utilizing finite element models taking into account glucose, oxygen, and hydrogen ions diffusion, consumption and production, as well as cell proliferation, migration and death, addressing how tumor cells evolve under different conditions. The resulting mathematical model was examined under different scenarios, being capable of reproducing cell death and proliferation under different cell concentrations, and the formation of a necrotic core, in good agreement with experimental data reported in the literature. This approach not only advances our fundamental understanding of necrotic core formation but also provides a robust computational platform to study personalized therapeutic strategies, offering an important tool in cancer research and treatment design.


Assuntos
Dispositivos Lab-On-A-Chip , Modelos Biológicos , Necrose , Neoplasias , Humanos , Neoplasias/patologia , Simulação por Computador , Proliferação de Células , Microambiente Tumoral/fisiologia
7.
Int J Legal Med ; 138(4): 1447-1458, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38386034

RESUMO

Post-mortem computed tomography (PMCT) enables the creation of subject-specific 3D head models suitable for quantitative analysis such as finite element analysis (FEA). FEA of proposed traumatic events is an objective and repeatable numerical method for assessing whether an event could cause a skull fracture such as seen at autopsy. FEA of blunt force skull fracture in adults with subject-specific 3D models in forensic pathology remains uninvestigated. This study aimed to assess the feasibility of FEA for skull fracture analysis in routine forensic pathology. Five cases with blunt force skull fracture and sufficient information on the kinematics of the traumatic event to enable numerical reconstruction were chosen. Subject-specific finite element (FE) head models were constructed by mesh morphing based on PMCT 3D models and A Detailed and Personalizable Head Model with Axons for Injury Prediction (ADAPT) FE model. Morphing was successful in maintaining subject-specific 3D geometry and quality of the FE mesh in all cases. In three cases, the simulated fracture patterns were comparable in location and pattern to the fractures seen at autopsy/PMCT. In one case, the simulated fracture was in the parietal bone whereas the fracture seen at autopsy/PMCT was in the occipital bone. In another case, the simulated fracture was a spider-web fracture in the frontal bone, whereas a much smaller fracture was seen at autopsy/PMCT; however, the fracture in the early time steps of the simulation was comparable to autopsy/PMCT. FEA might be feasible in forensic pathology in cases with a single blunt force impact and well-described event circumstances.


Assuntos
Análise de Elementos Finitos , Patologia Legal , Imageamento Tridimensional , Fraturas Cranianas , Tomografia Computadorizada por Raios X , Humanos , Fraturas Cranianas/diagnóstico por imagem , Fraturas Cranianas/patologia , Masculino , Patologia Legal/métodos , Adulto , Feminino , Pessoa de Meia-Idade , Autopsia/métodos , Idoso
8.
Nanotechnology ; 35(28)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38412533

RESUMO

Transparent heaters (THs) find widespread application in various indoor and outdoor settings, such as LCD panels and motorcycle helmet visors. Among the materials used for efficient TH performance, the AgNW network stands out due to its high conductivity, substantial transmittance, and minimal solution requirement. Extensive research has been directed towards enhancing AgNW characteristics, focusing on smaller diameters and longer wires. In TH applications, the primary considerations include a rapid response and elevated temperature. Consequently, this research delves into investigating the impact of parameters like diameter, length, and density on random AgNW networks under varying applied voltages. The finite element method is employed for analyzing temperature changes in response to voltage application, particularly in scenarios involving small-scale setups with high-density and high-percolation AgNW networks. The results reveal a significant increase in the thermal transition rate, ranging from 28% to 36%, with varying densities in the random network. Within the same density, the AgNW network with larger diameters and lengths demonstrates the highest temperatures, aligning with previous calculations. Furthermore, a trade-off exists between optical properties in smaller diameters and electrical properties in larger diameters within a relatively narrow temperature range.

9.
Nanotechnology ; 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39047758

RESUMO

Rare earth orthoniobates (RENbO4) are one kind of important functional materials due to its applications in solid-state phosphors, thermal barrier coatings, and microwave dielectric ceramics. The synthesis of rare earth niobates often needs high reaction temperatures (1300 ~ 1700 C) and long processing times (from hours to tens of hours) in solid-state reactions, which can increase the study time of the relationship between structure and properties. In this work, we used ultrafast high-temperature sintering method to synthesize RENbO4 (RE = La, Eu, Gd, Yb, Lu), and found specific structure and properties in these materials obtained with specific synthetic techniques. Based on the electronegativity scale, the charge transfer energy of lanthanide ions in the YNbO4 crystal was calculated. The rapid synthesis of RENbO4 in a vacuum atmosphere generated more oxygen vacancies, and the structures of [REO8] and [NbO6] were distorted. The shortening of the fluorescence lifetime of LaNbO4 and EuNbO4 was related to the formation of self-trapped excitons (STEs) facilitated by lattice distortion. The emission peak of LuNbO4 at about 530 nm is attributed to the oxygen vacancy in the niobate group. The reported synthetic methods can provide a fast materials screening route for high melting point inorganic materials.

10.
Macromol Rapid Commun ; 45(3): e2300526, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37877649

RESUMO

Nature with its abundant source offers numerous inspirations for structural and engineering designs. The oriented membranes stacked with bouligand structures in the fish scales show an outstanding combination of high strength and crack resistance. Although the applications of hard biomimetic composites are reported, the structures are rarely utilized in soft materials. Inspired by the scales of various fishes, electrospun membranes are used and stacked to fabricate bouligand elastomers, including orthogonal-plywood, single-bouligand, and double-bouligand structures. The effects of different structures on the properties of elastomers are systematically investigated and possible mechanism is explained using finite element analysis (FEA). The stiffness and fatigue characteristics of these biomimetic elastomers with the above structures are improved compared with the original membranes, especially the elastomers with a single-bouligand structure, which can undergo 5 000 cycles at a maximum strain of 35% without complete failure. The crack only propagates to half of the width of the elastomer with remaining strength of 50% of its original strength. Moreover, the mechanical performance can be adjusted by regulating the proportion of the components. The excellent crack-resistant properties and transparency promote its various potential applications.


Assuntos
Elastômeros , Peixes , Animais , Elastômeros/química
11.
Eur J Oral Sci ; 132(2): e12971, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38235853

RESUMO

The current study evaluated the stress distribution in a maxillary central incisor with mid-root fracture after splinting with different intra-radicular posts using 3D-finite element analysis (FEA). Five 3D-FEA models were constructed. Model 1 was an intact tooth with no fracture, Model 2: A tooth with a horizontal mid-root fracture, with no treatment. Model 3: Same as model 2, and intraradicular splinting using fiber post. Model 4: Same as model 2 and intra-radicular splinting using Protaper Gold file F3. Model 5: Same as model 2, and with intraradicular splinting with Ribbond. The FEA of all models was done to obtain the maximum Von-Mises stress in the root canal space, the dentin, the periodontal ligament, and the bone. The highest Von Mises stresses for the root canal space and the dentin were found in Model 3, followed by models 4, 5, and 2, and least in Model 1. The Von Mises stress of the periodontal ligament was the least in model 1. The Von Mises stress of bone was higher in all experimental models than in the baseline model. The results suggest that in cases where intra-radicular splinting is indicated, fiber posts and Ribbond are better alternatives to endodontic files due to the lower stresses exerted.


Assuntos
Polietilenos , Técnica para Retentor Intrarradicular , Análise de Elementos Finitos , Dentina , Incisivo , Estresse Mecânico
12.
J Biomech Eng ; 146(5)2024 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-38441207

RESUMO

Computer simulations play an important role in a range of biomedical engineering applications. Thus, it is important that biomedical engineering students engage with modeling in their undergraduate education and establish an understanding of its practice. In addition, computational tools enhance active learning and complement standard pedagogical approaches to promote student understanding of course content. Herein, we describe the development and implementation of learning modules for computational modeling and simulation (CM&S) within an undergraduate biomechanics course. We developed four CM&S learning modules that targeted predefined course goals and learning outcomes within the febio studio software. For each module, students were guided through CM&S tutorials and tasked to construct and analyze more advanced models to assess learning and competency and evaluate module effectiveness. Results showed that students demonstrated an increased interest in CM&S through module progression and that modules promoted the understanding of course content. In addition, students exhibited increased understanding and competency in finite element model development and simulation software use. Lastly, it was evident that students recognized the importance of coupling theory, experiments, and modeling and understood the importance of CM&S in biomedical engineering and its broad application. Our findings suggest that integrating well-designed CM&S modules into undergraduate biomedical engineering education holds much promise in supporting student learning experiences and introducing students to modern engineering tools relevant to professional development.


Assuntos
Currículo , Estudantes , Humanos , Fenômenos Biomecânicos , Software , Simulação por Computador
13.
J Biomech Eng ; 146(8)2024 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-38345603

RESUMO

Phonation onset is characterized by the unstable growth of vocal fold (VF) vibrations that ultimately results in self-sustained oscillation and the production of modal voice. Motivated by histological studies, much research has focused on the role of the layered structure of the vocal folds in influencing phonation onset, wherein the outer "cover" layer is relatively soft and the inner "body" layer is relatively stiff. Recent research, however, suggests that the body-cover (BC) structure over-simplifies actual stiffness distributions by neglecting important spatial variations, such as inferior-superior (IS) and anterior-posterior gradients and smooth transitions in stiffness from one histological layer to another. Herein, we explore sensitivity of phonation onset to stiffness gradients and smoothness. By assuming no a priori stiffness distribution and considering a second-order Taylor series sensitivity analysis of phonation onset pressure with respect to stiffness, we find two general smooth stiffness distributions most strongly influence onset pressure: a smooth stiffness containing aspects of BC differences and IS gradients in the cover, which plays a role in minimizing onset pressure, and uniform increases in stiffness, which raise onset pressure and frequency. While the smooth stiffness change contains aspects qualitatively similar to layered BC distributions used in computational studies, smooth transitions in stiffness result in higher sensitivity of onset pressure than discrete layering. These two general stiffness distributions also provide a simple, low-dimensional, interpretation of how complex variations in VF stiffness affect onset pressure, enabling refined exploration of the effects of stiffness distributions on phonation onset.


Assuntos
Modelos Anatômicos , Prega Vocal , Fonação , Vibração , Motivação
14.
Orthod Craniofac Res ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38651920

RESUMO

OBJECTIVE: This study aimed to investigate the biomechanical effects of clear aligner (CA) with different shape designs at extraction space (CAES) area during space closing. MATERIALS AND METHODS: A finite-element method (FEM) model of mandibular dentition, periodontal ligaments, attachments, and corresponding CA was established. The connecting rod design of CAES was modelled for the control group. Eight test groups with different heights of CAES from -4 mm to +4 mm were designed. Tooth displacement tendencies were calculated. The maximum principal stress in PDLs, teeth, and CAs was analysed. Both global coordinate system and local coordinate system were also used to evaluate individual tooth movements. RESULTS: Across all groups, stresses concentrated on the lingual outer surface of CAESs. For the lowered CAES groups, both the stress value and the stress distribution area at CAESs were increased. The lowered CAES groups showed reduced movement in anterior teeth and less tipping tendency of the canines. CONCLUSION: The shape of CAES has a biomechanical impact on anterior teeth movement and should be considered in aligner design. The results suggest that increasing the height of CAES can enhance anterior teeth retraction, while lowered CAES may facilitate controlled root movement. Changes in the shape of CAES represent a potential direction for biomechanical improvement of clear aligner in extraction cases and are worth exploring.

15.
Orthod Craniofac Res ; 2024 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-38247223

RESUMO

OBJECTIVE: This study aims to utilize the finite element method (FEM) to compare the dentoalveolar and mandibular effects associated with anterior mandibular repositioning using AdvanSync® (ADV) and Twin Block (TB). METHODS: A patient with Class II skeletal malocclusion and mandibular retrognathism was selected. A TB appliance was subsequently applied. Computed Tomography (CT) scans were acquired at the beginning of treatment (T1) and 8 months later (T2). Concurrently, a numerical TB model was validated through FEM simulations, which were compared with the T2 results. The ADV appliance was virtually simulated to evaluate stress and deformation on the condyle, symphysis, first lower molar and lower central incisors. RESULTS: Both simulations demonstrated significant mandibular advancement. However, ADV led to less incisor proclination and more molar intrusion compared to TB. ADV exhibited increased stress in the lower molar area, while TB had higher stress in the lower incisor region. Stress and deformations in the condyle and mandibular symphysis were similar in both simulations, with the highest stress observed at the condylar neck and the lowest at the upper pole of the condylar head. CONCLUSIONS: Both appliances achieved similar levels of mandibular advancement, with greater proclination of the lower central incisors and more widespread distribution of stress and molar intrusion when using ADV compared to TB.

16.
Orthod Craniofac Res ; 27(1): 102-109, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37496461

RESUMO

OBJECTIVE: This finite element analysis (FEA) aimed to assess the stress distribution in the mandible and fixation system with various directions of the intermaxillary fixation (IMF) using mini-implants (MIs) and elastics following mandibular advancement with a bilateral sagittal split ramus osteotomy (BSSRO). MATERIALS AND METHODS: A total of nine mandibular advancement models were set according to the position of the MIs (1.6 mm in diameter, 8 mm in length) and direction of the IMF elastics (1/4 inch, 5 oz). Major and minor principal stresses in the cortical and cancellous bones, von Mises stresses in the fixation system (miniplate and monocortical screws), and bending angles of the miniplate were analysed. RESULTS: Compressive and tensile stress distributions in the mandible and von Mises stress distributions in the fixation system were greater in models with a Class III IMF elastic direction and a higher IMF elastic force than in models with a Class II IMF elastic direction and a lower IMF elastic force. The bending angle of the miniplate was negligible. CONCLUSIONS: Stress distributions in the bone and fixation system varied depending on the direction, amount of force, and position of IMF elastics and MIs. Conclusively, IMF elastics in the Class II direction with minimal load in the area close to the osteotomy site should be recommended.


Assuntos
Implantes Dentários , Avanço Mandibular , Procedimentos de Ancoragem Ortodôntica , Osteotomia Sagital do Ramo Mandibular , Análise de Elementos Finitos , Placas Ósseas , Parafusos Ósseos , Estresse Mecânico , Mandíbula/cirurgia
17.
Proc Natl Acad Sci U S A ; 118(10)2021 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-33658360

RESUMO

Located in the forelegs, katydid ears are unique among arthropods in having outer, middle, and inner components, analogous to the mammalian ear. Unlike mammals, sound is received externally via two tympanic membranes in each ear and internally via a narrow ear canal (EC) derived from the respiratory tracheal system. Inside the EC, sound travels slower than in free air, causing temporal and pressure differences between external and internal inputs. The delay was suspected to arise as a consequence of the narrowing EC geometry. If true, a reduction in sound velocity should persist independently of the gas composition in the EC (e.g., air, [Formula: see text]). Integrating laser Doppler vibrometry, microcomputed tomography, and numerical analysis on precise three-dimensional geometries of each experimental animal EC, we demonstrate that the narrowing radius of the EC is the main factor reducing sound velocity. Both experimental and numerical data also show that sound velocity is reduced further when excess [Formula: see text] fills the EC. Likewise, the EC bifurcates at the tympanal level (one branch for each tympanic membrane), creating two additional narrow internal sound paths and imposing different sound velocities for each tympanic membrane. Therefore, external and internal inputs total to four sound paths for each ear (only one for the human ear). Research paths and implication of findings in avian directional hearing are discussed.


Assuntos
Estruturas Animais , Meato Acústico Externo , Gryllidae , Audição/fisiologia , Membrana Timpânica , Estruturas Animais/anatomia & histologia , Estruturas Animais/fisiologia , Animais , Meato Acústico Externo/anatomia & histologia , Meato Acústico Externo/fisiologia , Gryllidae/anatomia & histologia , Gryllidae/fisiologia , Membrana Timpânica/anatomia & histologia , Membrana Timpânica/fisiologia
18.
BMC Musculoskelet Disord ; 25(1): 285, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609902

RESUMO

OBJECTIVE: To investigate the effect of bone cement on the vertebral body and biomechanical properties in percutaneous cement discoplasty (PCD) for degenerative lumbar disc disease. METHODS: Three-dimensional reconstruction of L2 ~ L3 vertebral bodies was performed in a healthy volunteer, and the corresponding finite element model of the spine was established. Biomechanical analysis was performed on the changes in stress distribution in different groups of models by applying quantitative loads. RESULTS: Models with percutaneous discoplasty (PCD) showed improved stability under various stress conditions, and intervertebral foraminal heights were superior to models without discoplasty. CONCLUSION: Cement discoplasty can improve the stability of the vertebral body to a certain extent and restore a certain height of the intervertebral foramen, which has a good development prospect and potential.


Assuntos
Escoliose , Humanos , Escoliose/diagnóstico por imagem , Escoliose/cirurgia , Análise de Elementos Finitos , Cimentos Ósseos/uso terapêutico , Coluna Vertebral , Voluntários Saudáveis
19.
BMC Musculoskelet Disord ; 25(1): 446, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844920

RESUMO

BACKGROUND: Femoral neck system (FNS) has exhibited some drawbacks, such as non-fit of the plate with the lateral femoral cortex, postoperative pain, and the potential risk of subtrochanteric fractures. We have developed a low-profile FNS system that addresses some compatibility issues in FNS. In this study, we conducted finite element analysis on the 1-hole FNS (1 H-FNS), 2-holes FNS (2 H-FNS), and low-profile FNS (LP-FNS) and compared their biomechanical performance. METHODS: After the mesh convergence analysis, we established three groups of 1 H-FNS, 2 H-FNS, and LP-FNS. The interfragmentary gap, sliding distance, shear stress, and compressive stress and the bone-implant interface compression stress, stiffness, and displacement were determined under the neutral, flexion, or extension conditions of the hip joint, respectively. The stress and displacement of the femur after the implant removal were also investigated. RESULTS: (1) There were no obvious differences among the three FNS groups in terms of the IFM distance. However, the LP-FNS group showed less rotational angle compared with conventional FNS (neutral: 1 H-FNS, -61.64%; 2 H-FNS, -45.40%). Also, the maximum bone-implant interface compression stress was obviously decreased under the neutral, flexion, or extension conditions of the hip joint (1 H-FNS: -6.47%, -20.59%, or -4.49%; 2 H-FNS: -3.11%, 16.70%, or -7.03%; respectively). (2) After the implant removal, there was no notable difference in the maximum displacement between the three groups, but the maximum von Mises stress displayed a notable difference between LP-FNS and 1 H-FNS groups (-15.27%) except for the difference between LP-FNS and 2 H-FNS groups (-4.57%). CONCLUSIONS: The LP-FNS may not only provide the same biomechanical stabilities as the 1 H-FNS and 2 H-FNS, but also have more advantages in rotational resistance especially under the neutral condition of the hip joint, in the bone-implant interface compression stress, and after the implant removal. In addition, the 1 H-FNS and 2 H-FNS have similar biomechanical stabilities except for the maximum von Mises stress after the implant removal. The femur after the LP-FNS removal not only is subjected to relatively little stress but also minimizes stress concentration areas.


Assuntos
Parafusos Ósseos , Fraturas do Colo Femoral , Análise de Elementos Finitos , Humanos , Fraturas do Colo Femoral/cirurgia , Fenômenos Biomecânicos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Estresse Mecânico , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/cirurgia
20.
BMC Musculoskelet Disord ; 25(1): 197, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38443904

RESUMO

BACKGROUND: A reduction in total lumbar range of motion (ROM) after lumbar fusion may offset the increase in intradiscal pressure (IDP) and facet joint force (FJF) caused by the abnormally increased ROM at adjacent segments. This study aimed to determine a relative total lumbar ROM rather than an ideal adjacent segment ROM to guide postoperative waist activities and further delay adjacent segment degeneration (ASD). METHODS: An intact L1-S1 finite element model was constructed and validated. Based on this, a surgical model was created to allow the simulation of L4/5 transforaminal lumbar interbody fusion (TLIF). Under the maximum total L1-S1 ROM, the ROM, IDP, and FJF of each adjacent segment between the intact and TLIF models were compared to explore the biomechanical influence of lumbar fusion on adjacent segments. Subsequently, the functional relationship between total L1-S1 ROM and IDP or total L1-S1 ROM and FJF was fitted in the TLIF model to calculate the relative total L1-S1 ROMs without an increase in IDP and FJF. RESULTS: Compared with those of the intact model, the ROM, IDP, and FJF of the adjacent segments in the TLIF model increased by 12.6-28.9%, 0.1-6.8%, and 0-134.2%, respectively. As the total L1-S1 ROM increased, the IDP and FJF of each adjacent segment increased by varying degrees. The relative total L1-S1 ROMs in the TLIF model were 11.03°, 12.50°, 12.14°, and 9.82° in flexion, extension, lateral bending, and axial rotation, respectively. CONCLUSIONS: The relative total L1-S1 ROMs after TLIF were determined, which decreased by 19.6-29.3% compared to the preoperative ones. Guiding the patients to perform postoperative waist activities within these specific ROMs, an increase in the IDP and FJF of adjacent segments may be effectively offset, thereby alleviating ASD.


Assuntos
Vértebras Lombares , Fusão Vertebral , Humanos , Análise de Elementos Finitos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Fusão Vertebral/efeitos adversos , Amplitude de Movimento Articular , Simulação por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA