Resultados 1 - 20 de 62
Filtrar
1.
Exp Brain Res ; 2024 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-39368025

RESUMO

Ischemic Conditioning (IC) is a procedure involving brief periods of occlusion followed by reperfusion in stationary limbs. Blood Flow Restriction with Exercise (BFR-E) is a technique comprising blood flow restriction during aerobic or resistance exercise. Both IC and BFR-E are Blood Flow Modulation (BFM) strategies that have shown promise across various health domains and are clinically relevant for stroke rehabilitation. Despite their potential benefits, our knowledge on the application and efficacy of either intervention in stroke is limited. This scoping review aims to synthesize the existing literature on the impact of IC and BFR-E on motor and neurophysiological outcomes in individuals post-stroke. Evidence from five studies displayed enhancements in paretic leg strength, gait speed, and paretic leg fatiguability after IC. Additionally, BFR-E led to improvements in clinical performance, gait parameters, and serum lactate levels. While trends toward motor function improvement were observed post-intervention, statistically significant differences were limited. Neurophysiological changes showed inconclusive results. Our review suggests that IC and BFR-E are promising clinical approaches in stroke, however high-quality studies focusing on neurophysiological mechanisms are required to establish the efficacy and underlying mechanisms of both in stroke. Recommendations regarding future directions and clinical utility are provided.

2.
Nano Lett ; 23(19): 8860-8867, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37732878

RESUMO

Tailoring heat flow in solids has profound implications for the innovation of functional thermal devices. However, the current methods face technological challenges related to system complexity, material stability, and operating temperature. In this study, we demonstrated efficient heat flow modulation in a single material without a phase transition, using a simple and entirely material-independent strategy, kinked nanostructure patterning, at near-ambient temperature. By carefully controlling the kink arm length and kink angle of the Si nanoribbons, we achieved a thermal conductivity modulation of up to ∼20%. Our theoretical modeling showed that this modulation results from the competing roles of phonon backscattering and open view channels on heat transport. We also build a regime map based on the existence of an open view channel and provide concrete design guidelines for thermal conductivity modulation considering the kink angle and arm length. This study opens up new opportunities for efficient heat flow manipulation through nanostructure patterning.

3.
Cells Tissues Organs ; 212(3): 272-284, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35344966

RESUMO

Continuous flow ventricular assist device (CFVAD) support in advanced heart failure patients causes diminished pulsatility, which has been associated with adverse events including gastrointestinal bleeding, end organ failure, and arteriovenous malformation. Recently, pulsatility augmentation by pump speed modulation has been proposed as a means to minimize adverse events. Pulsatility primarily affects endothelial and smooth muscle cells in the vasculature. To study the effects of pulsatility and pulse modulation using CFVADs, we have developed a microfluidic co-culture model with human aortic endothelial (ECs) and smooth muscle cells (SMCs) that can replicate physiologic pressures, flows, shear stresses, and cyclical stretch. The effects of pulsatility and pulse frequency on ECs and SMCs were evaluated during (1) normal pulsatile flow (120/80 mmHg, 60 bpm), (2) diminished pulsatility (98/92 mmHg, 60 bpm), and (3) low cyclical frequency (115/80 mmHg, 30 bpm). Shear stresses were estimated using computational fluid dynamics (CFD) simulations. While average shear stresses (4.2 dynes/cm2) and flows (10.1 mL/min) were similar, the peak shear stresses for normal pulsatile flow (16.9 dynes/cm2) and low cyclic frequency (19.5 dynes/cm2) were higher compared to diminished pulsatility (6.45 dynes/cm2). ECs and SMCs demonstrated significantly lower cell size with diminished pulsatility compared to normal pulsatile flow. Low cyclical frequency resulted in normalization of EC cell size but not SMCs. SMCs size was higher with low frequency condition compared to diminished pulsatility but did not normalize to normal pulsatility condition. These results may suggest that pressure amplitude augmentation may have a greater effect in normalizing ECs, while both pressure amplitude and frequency may be required to normalize SMCs morphology. The co-culture model may be an ideal platform to study flow modulation strategies.


Assuntos
Coração Auxiliar , Humanos , Técnicas de Cocultura , Miócitos de Músculo Liso
4.
Anal Bioanal Chem ; 415(13): 2399-2409, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36301331

RESUMO

This study examines how the height and width of peaks exiting the secondary column of a comprehensive two-dimensional gas chromatography (GC × GC) separation are affected by the width of the pulse introduced to the secondary column. A flow-modulated GC × GC apparatus was assembled that allowed input pulse widths to be controlled precisely over a range of 10 to 70 ms. GC × GC chromatograms were obtained using secondary columns containing a polyethylene glycol stationary phase with internal diameters of 0.25 and 0.32 mm. The area, height, and width of peaks emerging from the secondary column were found to be accurately modeled by the convolution of a rectangular function with a Gaussian distribution. The rectangular function represents the input pulse, and the Gaussian distribution represents the broadening that occurs in the secondary column. The minimum peak width that could be produced by the secondary column was determined for a wide range of compounds. Injection pulse widths that matched a compound's minimum peak width produced peaks that were 25% wider than the minimum width and had heights that were 76% of the maximum possible peak height. Increasing the injection width significantly above the minimum width yielded substantially broader peaks with only a modest increase (< 25%) in peak height.

5.
J Sep Sci ; 46(13): e2300067, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37050870

RESUMO

The conventional reverse fill/flush flow modulation for comprehensive two-dimensional gas chromatography requires a bleed capillary column to be connected to the outlet of the modulator channel. The purpose of this capillary, which does not contain the stationary phase, is to provide pressure resistance to the modulator channel flow. In this way, the desired modulator volumetric flow can be achieved, and channel over-filling can be avoided. Normally, the length and the internal diameter of the bleed capillary are chosen so as to obtain the modulator flow that is close to the flow of the first separation column. Thus, for any chosen set of chromatographic conditions, the required dimensions of the bleed capillary can be completely different, making the two-dimensional gas chromatography method development tedious and generating additional costs in consumables and analyst time. In this work, a tuneable pressure source generating a suitable backpressure was used instead of the fixed bleed capillary which has the advantage of the possibility to freely adapt the pressure resistance and generate the required modulator channel flow for any conditions. This set-up has been evaluated and compared in terms of the impact on the modulation performance to the set-up involving a fixed bleed capillary demonstrating comparable performance.

6.
Anal Bioanal Chem ; 414(21): 6371-6378, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35499702

RESUMO

The present research is focused on the use and evaluation of hydrogen, as a more sustainable alternative to helium, within the context of fast flow modulation comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry. In such a respect, a comparison was made between the two mobile phases in terms of speed and overall chromatography performance. All experiments were carried out by using the following column set: low polarity with dimensions 10 m × 0.25 mm ID × 0.25 µm df and medium polarity with dimensions 2 m × 0.10 mm ID × 0.10 µm df. Fundamental gas chromatography parameters (efficiency, resolution) were measured under different experimental conditions, using the two carrier gases. Efficiency was measured in both the first and second dimensions, using a probe compound under isothermal conditions; after defining the optimum carrier gas conditions, a mixture containing 20 pesticides was analyzed to measure resolution, again in the first and second dimensions, using a temperature program. It was found (as expected) that a similar chromatography performance could be attained when using hydrogen, albeit with a circa 25% reduction in analysis time. Signal-to-noise ratios of the pesticides were calculated, using both carrier gases, with such values generally reduced (on average by 14%) when using hydrogen. Finally, a comparison was made between mass spectral profiles obtained analyzing the pesticides and fatty acid methyl esters using the two mobile phases. Even though mass spectral differences were observed, the ion profiles could be considered generally similar.


Assuntos
Hélio , Praguicidas , Ácidos Graxos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Hidrogênio , Espectrometria de Massas/métodos
7.
Artif Organs ; 46(5): 887-898, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34866200

RESUMO

BACKGROUND: Patients with continuous flow ventricular assist devices (CF-VADs) are at high risk for non-surgical bleeding, speculated to associate with the loss of pulsatility following CF-VAD placement. It has been hypothesized that continuous shear stress causes elongation and increased enzymatic degradation of von Willebrand Factor (vWF), a key player in thrombus formation at sites of vascular damage. However, the role of loss of pulsatility on the unravelling behavior of vWF has not been widely explored. METHODS: vWF molecules were immobilized on the surface of microfluidic devices and subjected to various pulsatile flow profiles, including continuous flow and pulsatile flow of different magnitudes, dQ/dt (i.e., first derivative of flow rate) of pulsatility and pulse frequencies to mimic in vivo shear flow environments with and without CF-VAD support. VWF elongation was observed using total internal reflection fluorescence (TIRF) microscopy. Besides, the vWF level is measured from the patients' blood sample before and after CF-VAD implantation from a clinical perspective. To our knowledge, this work is the first in providing direct, visual observation of single vWF molecule extension under controlled-pulsatile shear flow. RESULTS: Unravelling of vWF (total sample size n ~ 200 molecules) is significantly reduced under pulsatile flow (p < 0.01) compared to continuous flow. An increase in the magnitude of pulsatility further reduces unravelling lengths, while lower frequency of pulsatility (20 vs. 60 pulses per min) does not have a major effect on the maximum or minimum unravelling lengths. Evaluation of CF-VAD patient blood samples (n = 13) demonstrates that vWF levels decreased by ~40% following CF-VAD placement (p < 0.01), which correlates to single-molecule observations from a clinical point of view. CONCLUSIONS: Pulsatile flow reduces unfolding of vWF compared to continuous flow and a lower pulse frequency of 20 pulses/minute yielded comparable vWF unfolding to 60 pulses/minute. These findings could shed light on non-surgical bleeding associated with the loss of pulsatility following CF-VAD placement.


Assuntos
Coração Auxiliar , Trombose , Coração Auxiliar/efeitos adversos , Hemorragia/etiologia , Humanos , Fluxo Pulsátil , Trombose/etiologia , Fator de von Willebrand/metabolismo
8.
Sensors (Basel) ; 21(16)2021 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-34451035

RESUMO

In standard critical care practice, cuff sphygmomanometry is widely used for intermittent blood pressure (BP) measurements. However, cuff devices offer ample possibility of modulating blood flow and pulse propagation along the artery. We explore underutilized arrangements of sensors involving cuff devices which could be of use in critical care to reveal additional information on compensatory mechanisms. In our previous work, we analyzed the response of the vasculature to occlusion perturbations by means of observations obtained non-invasively. In this study, our aim is to (1) acquire additional insights by means of invasive measurements and (2) based on these insights, further develop cuff-based measurement strategies. Invasive BP experimental data is collected downstream from the cuff in two patients monitored in the OR. It is found that highly dynamic processes occur in the distal arm during cuff inflation. Mean arterial pressure increases in the distal artery by 20 mmHg, leading to a decrease in pulse transit time by 20 ms. Previous characterizations neglected such distal vasculature effects. A model is developed to reproduce the observed behaviors and to provide a possible explanation of the factors that influence the distal arm mechanisms. We apply the new findings to further develop measurement strategies aimed at acquiring information on pulse arrival time vs. BP calibration, artery compliance, peripheral resistance, artery-vein interaction.


Assuntos
Determinação da Pressão Arterial , Análise de Onda de Pulso , Artérias , Pressão Sanguínea , Frequência Cardíaca , Humanos
9.
J Sep Sci ; 43(9-10): 1790-1799, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31674101

RESUMO

Headspace gas chromatography is frequently used for aroma profiling thanks to its ability to naturally exploit the volatility of aroma compounds, and also to provide chemical information on sample composition. Its main advantages rely on simplicity, no use of solvent, amenability to automation, and the cleanliness of the extract. In the present contribution, the most effective sampling (dynamic extraction), separation (multidimensional gas chromatography), and detection (mass spectrometry) techniques for untargeted analysis are exploited in combination, showing their potential in unraveling aroma profiles in fruit beers. To complete the overall analytical process, a neat workflow for data analysis is discussed and used for the successful characterization and identification of five different beer flavors (berries, cherry, banana, apple, and peach). From the technical viewpoint, the coupling of purge-and-trap, comprehensive two-dimensional gas chromatography, and mass spectrometry makes the global methodology unique, and it is for the first time discussed. A (low-)flow modulation approach allowed for the full transfer into the second dimension with mass-spectrometry compatible flow (< 7 mL/min), avoiding the need of splitting before detection and making the overall method sensitive (1.2-5.2-fold higher signal to noise ratio compared to unmodulated gas chromatography conditions) and selective.


Assuntos
Cerveja/análise , Odorantes/análise , Cromatografia Gasosa , Espectrometria de Massas
10.
Am J Physiol Gastrointest Liver Physiol ; 317(3): G264-G274, 2019 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-31216172

RESUMO

Extended liver resection results in loss of a large fraction of the hepatic vascular bed, thereby causing abrupt alterations in perfusion of the remnant liver. Mechanisms of hemodynamic adaptation and associated changes in oxygen metabolism after liver resection and the effect of mechanical portal blood flow reduction were assessed. A pig model (n = 16) of extended partial hepatectomy was established that included continuous observation for 24 h under general anesthesia. Pigs were randomly separated into two groups, one with a portal flow reduction of 70% compared with preoperative values, and the other as a control (n = 8, each). In controls, portal flow [mean (SD)] increased from 74 (8) mL·min-1·100 g-1 preoperatively to 240 (48) mL·min-1·100 g-1 at 6 h after resection (P < 0.001). Hepatic arterial buffer response was abolished after resection. Oxygen uptake per unit liver mass increased from 4.0 (1.1) mL·min-1·100 g-1 preoperatively to 7.7 (1.7) mL·min-1·100 g-1 8 h after resection (P = 0.004). Despite this increase in relative oxygen uptake, total hepatic oxygen consumption (V̇o2) was not maintained, and markers of hypoxia and anaerobic metabolism were significantly increased in hepatocytes after resection. Reduced postoperative portal flow was associated with significantly decreased levels of aspartate aminotransferase and bilirubin and increased hepatic clearance of indocyanine green. In conclusion, major liver resection was associated with persistent portal hyperperfusion, loss of the hepatic arterial buffer response, decreased total hepatic V̇o2 and with increased anaerobic metabolism. Portal flow modulation by partial portal vein occlusion attenuated liver injury after extended liver resection.NEW & NOTEWORTHY Because of continuous monitoring, the experiments allow precise observation of the influence of liver resection on systemic and local abdominal hemodynamic alterations and oxygen metabolism. Major liver resection is associated with significant and persistent portal hyperperfusion and loss of hepatic arterial buffer response. The correlation of portal hyperperfusion and parameters of liver injury and dysfunction offers a novel therapeutic option to attenuate liver injury after extended liver resection.


Assuntos
Circulação Hepática/fisiologia , Regeneração Hepática/fisiologia , Fígado/irrigação sanguínea , Fígado/cirurgia , Animais , Aspartato Aminotransferases/metabolismo , Feminino , Hemodinâmica/efeitos dos fármacos , Hepatectomia , Fígado/metabolismo , Masculino , Microcirculação/fisiologia , Pressão na Veia Porta/fisiologia , Veia Porta/fisiologia , Substâncias Protetoras/farmacologia , Suínos
11.
Anal Bioanal Chem ; 410(22): 5507-5519, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29236133

RESUMO

We explored the use of pulsed flow modulation (PFM) two-dimensional comprehensive gas chromatography (GCxGC) mass spectrometry with supersonic molecular beams (SMB) (also named Cold electron ionization (EI)) for achieving universal pesticide analysis in agricultural products. The use of GCxGC serves as an alternative to MS-MS in the needed reduction of matrix interference while enabling full-scan MS operation for universal pesticide analysis with reduced number of false negatives. Matrix interference is further reduced with Cold EI in view of the enhancement of the molecular ions. Pulsed flow modulation is a simple GCxGC modulator that does not consume cryogenic gases while providing tuneable second GCxGC column injection time for enabling the use of quadrupole-based mass spectrometry regardless its limited scanning speed. PFM-GCxGC-MS with Cold EI combines improved separation of GCxGC with Cold EI benefits of tailing-free ultra-fast ion source response time and enhanced molecular ions for the provision of increased sample identification information and reduced matrix interference. Consequently, PFM GCxGC-MS with Cold EI also improved NIST library identification probabilities of the spiked pesticides. PFM GCxGC is further characterized by largely increased second column sample and matrix capacity that as a result performs much better than thermal modulation GCxGC-MS with standard EI in the suppression of matrix interference. In a comparison with standard GC-MS, we measured with PFM GCxGC-MS with Cold EI an average total ion count matrix interference reduction factor of 32 for 12 pesticides in two matrices of baby leaves mixture and lettuce. In addition, Cold EI further increases the range of pesticides amenable for GC-MS analysis and its response is relatively uniform hence with it the need for pesticides specific calibration is reduced. Graphical abstract Pulsed flow modulation GCxGC-MS with Cold EI significantly reduces matrix interference and improves sample identification.


Assuntos
Contaminação de Alimentos/análise , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Praguicidas/análise , Espectrometria de Massas em Tandem/instrumentação , Agricultura , Desenho de Equipamento , Cromatografia Gasosa-Espectrometria de Massas/métodos , Análise de Perigos e Pontos Críticos de Controle/métodos , Espectrometria de Massas em Tandem/métodos
12.
Neurosurg Focus ; 42(6): E3, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28565988

RESUMO

OBJECTIVE Flow diversion has emerged as a viable treatment option for selected intracranial aneurysms and recently has been gaining traction. The aim of this study was to evaluate the safety and effectiveness of flow-diverter devices (FDDs) over a long-term follow-up period. METHODS The authors retrospectively reviewed all cerebral aneurysm cases that had been admitted to the Division of Neurosurgery of the Università degli Studi di Napoli between November 2008 and November 2015 and treated with an FDD. The records of 60 patients (48 females and 12 males) harboring 69 cerebral aneurysms were analyzed. The study end points were angiographic evidence of complete aneurysm occlusion, recanalization rate, occlusion of the parent artery, and clinical and radiological evidence of brain ischemia. The occlusion rate was evaluated according to the O'Kelly-Marotta (OKM) Scale for flow diversion, based on the degree of filling (A, total filling; B, subtotal filling; C, entry remnant; D, no filling). Postprocedural, midterm, and long-term results were strictly analyzed. RESULTS Complete occlusion (OKM D) was achieved in 63 (91%) of 69 aneurysms, partial occlusion (OKM C) in 4 (6%), occlusion of the parent artery in 2 (3%). Intraprocedural technical complications occurred in 3 patients (5%). Postprocedural complications occurred in 6 patients (10%), without neurological deficits. At the 12-month follow-up, 3 patients (5%) experienced asymptomatic cerebral infarction. No further complications were observed at later follow-up evaluations (> 24 months). There were no reports of any delayed aneurysm rupture, subarachnoid or intraparenchymal hemorrhage, ischemic complications, or procedure- or device-related deaths. CONCLUSIONS Endovascular treatment with an FDD is a safe treatment for unruptured cerebral aneurysms, resulting in a high rate of occlusion. In the present study, the authors observed effective and stable aneurysm occlusion, even at the long-term follow-up. Data in this study also suggest that ischemic complications can occur at a later stage, particularly at 12-18 months. On the other hand, no other ischemic or hemorrhagic complications occurred beyond 24 months.


Assuntos
Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos , Aneurisma Intracraniano/terapia , Stents , Adulto , Idoso , Angiografia Digital , Angiografia Cerebral , Procedimentos Endovasculares , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
13.
Sensors (Basel) ; 17(10)2017 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-29035335

RESUMO

In order to enhance the selectivity of metal oxide gas sensors, we use a flow modulation method to exploit transient sensor information. The method is based on modulating the flow of the carrier gas that brings the species to be measured into the sensor chamber. We present an active perception strategy by using a DQN which can optimize the flow modulation online. The advantage of DQN is not only that the classification accuracy is higher than traditional methods such as PCA, but also that it has a good adaptability under small samples and labeled data. From observed values of the sensors array and its past experiences, the DQN learns an action policy to change the flow speed dynamically that maximizes the total rewards (or minimizes the classification error). Meanwhile, a CNN is trained to predict sample class and reward according to current actions and observation of sensors. We demonstrate our proposed methods on a gases classification problem in a real time environment. The results show that the DQN learns to modulate flow to classify different gas and the correct rates of gases are: sesame oil 100%, lactic acid 80%, acetaldehyde 80%, acetic acid 80%, and ethyl acetate 100%, the average correct rate is 88%. Compared with the traditional method, the results of PCA are: sesame oil 100%, acetic acid 24%, acetaldehyde 100%, lactic acid 56%, ethyl acetate 68%, the average accuracy rate is 69.6%. DQN uses fewer steps to achieve higher recognition accuracy and improve the recognition speed, and to reduce the training and testing costs.

14.
J Endovasc Ther ; 23(3): 501-12, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26988746

RESUMO

PURPOSE: To examine the safety and short-term efficacy of the Streamliner Multilayer Flow Modulator (SMFM) in the management of patients with complex thoracoabdominal aortic pathology who are unfit for alternative interventions. METHODS: Biomedical databases were systematically searched for articles published between 2008 and 2015 on the SMFM. A patient-level meta-analysis was used to evaluate aneurysm-related survival. Secondary outcomes were all-cause survival, stroke, spinal cord ischemia, renal impairment, and branch vessel patency. Other considerations were the impact of compliance with the instructions for use (IFU) on clinical outcome. Mean values and Kaplan-Meier estimates are presented with the 95% confidence interval (CI). RESULTS: Fifteen articles (3 multicenter cohort studies, 3 observational cohort studies, and 9 case reports) were included, presenting 171 patients (mean age 68.8±12.3 years; 139 men). The mean aneurysm diameter was 6.7±1.6 cm (95% CI 6.4 to 6.9 cm). Technical success reported in 15 studies was 77.2%. Aneurysm-related survival at 1 year was 78.7% (95% CI 71.7% to 84.4%). One-year all-cause survival was 53.7% (95% CI 46.0% to 61.3%). There were no reported cases of spinal cord ischemia, renal insult, or stroke. CONCLUSION: The SMFM can be safely utilized in some patients with complex thoracoabdominal pathologies provided operators adhere to the IFU. The SMFM is a novel technology with no long-term published data on its sustained effectiveness and a lack of comparative studies. Randomized clinical trials, registries, and continued assessment are essential before this flow-modulating technology can be widely disseminated.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/fisiopatologia , Velocidade do Fluxo Sanguíneo , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Fluxo Sanguíneo Regional , Retratamento , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
15.
J Endovasc Ther ; 23(5): 762-72, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27280802

RESUMO

PURPOSE: To evaluate midterm outcomes of endovascular repair of types II and III thoracoabdominal aortic aneurysms (TAAA) using the Multilayer Flow Modulator (MFM) in patients unsuitable for open surgery or fenestrated stent-grafts. METHODS: In the prospective, multicenter, nonrandomized STRATO trial (EudraCT registration: 2009-013678-42; ClinicalTrials.gov identifier NCT01756911), 23 patients (mean age 75.8 years; 19 men) with Crawford type II and III TAAA (mean diameter 6.5 cm) were implanted between April 2010 and February 2011. Outcomes included all-cause mortality and stable aneurysm thrombosis with associated branch vessel patency. RESULTS: Through 36 months, there were 7 deaths (none confirmed as aneurysm-related), and no cases of spinal cord injury, device migration or fracture, or respiratory, renal, or peripheral complications. Three patients were lost to follow-up and 2 devices were explanted. The device was patent in the 11 remaining patients at 3 years. Stable aneurysm thrombosis was achieved for 15 of 20 patients at 12 months, 12 of 13 at 24 months, and 10 of 11 at 36 months. The rate of branch patency was 96% at 12 months (primary patency), 100% at 24 months, and 97% at 36 months. Nine patients suffered from endoleaks (attachment site or device overlap); 9 patients underwent 11 reinterventions (3 surgical). Maximum aneurysm diameter was stable for 18 of 20 patients at 12 months, 11 of 13 at 24 months, and 9 of 11 at 36 months. For 10 patients with computed tomography at 36 months, the mean ratio of aneurysm flow volume to total volume had decreased by 83%; the mean ratio of thrombus volume to total volume increased by 159%. CONCLUSION: Through 3 years, endovascular repair with the MFM appears to be safe and effective while successfully maintaining branch vessel patency.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Idoso , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia/métodos , Velocidade do Fluxo Sanguíneo , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , França , Humanos , Estimativa de Kaplan-Meier , Masculino , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Fluxo Sanguíneo Regional , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
16.
J Endovasc Ther ; 23(5): 773-82, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27381934

RESUMO

PURPOSE: To evaluate endovascular repair of thoracoabdominal aortic aneurysms (TAAA) and abdominal aortic aneurysms (AAA) using the Multilayer Flow Modulator (MFM) in high-surgical-risk patients with at least one covered branch vessel. METHODS: In this prospective single-center nonrandomized trial, 18 patients (mean age 61.1 years; 16 men) with TAAA (n=10, mean diameter 74.4 mm) and AAA (n=8, mean diameter 67.8 mm) were treated with the MFM between June 2009 and September 2012. The primary safety endpoints were all-cause mortality at 30 days and 12 months and neurological complications. The primary efficacy endpoint was overall procedure success, defined as patency of covered branch vessels, reductions in aneurysm diameter, and sac thrombus formation. RESULTS: The technical success rate was 100% (53 study devices implanted, mean stented length 273 mm). Through mean follow-up of 13.4 months, all 61 covered branch vessels remained patent; there were no neurologic complications, ruptures, or instances of device migration, kinking, or fracture. Three patients died, 2 of unrelated causes and one of an undetermined cause. Only one reintervention with an additional MFM implanted at 5 years was required for a type I endoleak in a young patient with natural growth. Carefully planned and executed diameter and volume measurements demonstrated aneurysm shrinkage and progressive sac thrombus formation for both patient groups. CONCLUSION: Through midterm follow-up, treatment of high-surgical-risk TAAA and AAA patients with the MFM appears to be safe and effective, maintaining branch vessel patency and reducing rupture risk through reduction of aneurysm diameter and modulation of flow dynamics. Longer term follow-up is needed.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Adolescente , Adulto , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia/métodos , Velocidade do Fluxo Sanguíneo , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Marrocos , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Fluxo Sanguíneo Regional , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular , Adulto Jovem
18.
J Sep Sci ; 39(12): 2284-91, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27120133

RESUMO

Comprehensive two-dimensional gas chromatography is a technique that is becoming more widespread within the analytical community, especially in the separation of complex mixtures. Modulation in comprehensive two-dimensional gas chromatography can be achieved by manipulating temperature or flow and offers many advantages such as increased separation power, but one underutilized advantage is increased detectability due to the reduction of peak width from the use of a modulator. A flow modulator was used to selectively target analytes for increased detectability with a standard flame ionization detector operated at 100 Hz, without the need for cryogens or advanced modulation software. By the collection of the entire peak volume followed by peak transfer rather than further separation, an increase of 12 times in peak height and detectability was realized for the analytes tested using an internal loop modulator configuration. An external loop flow modulator configuration allowed for more volatile analytes (with k < 5), and demonstrated an analyte detectability enhancement factor of at least 6. The collection loop size can be readily increased with an external loop configuration to accommodate for these naturally broader peaks. This novel flow modulated targeted signal enhancement approach was applied to industrially significant analyses like the analysis of methanol in a hydrocarbon streams. Methanol was detected at 7 ppb with a conventional flame ionization detector and without the need for pre-concentration.

19.
Pediatr Surg Int ; 32(4): 363-8, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26786017

RESUMO

PURPOSE: We aimed to evaluate patients who had undergone pediatric LDLT with small-for-size graft (SFSG) and identify risk factors of graft failure to establish a preoperative graft selection strategy. METHODS: The data was collected retrospectively. SFSG was used in 14LDLTs (5.7%) of 245 LDLTs performed between May 2001 and March 2014. The mean patient age and body weight at LDLT were 12.6 ± 2.0 years and 40.5 ± 9.9 kg, respectively. The graft type was left lobe in six patients, left + caudate lobe in seven patients, and posterior segment in one patient. RESULTS: The graft survival rates in SFSG and non-SFSG groups were 78.9 and 93.1%, respectively (p = 0.045). In the univariate analysis, bleeding volume during LDLT were an independent risk factors for graft failure (p = 0.011). Graft failure was caused by sepsis in all three patients and occurred at a median of 70 postoperative days 70 (range 14-88 days). Among them, two cases showed high preoperative PELD/MELD score (PELD; 19.4 and MELD; 22, respectively). CONCLUSIONS: Pediatric LDLT using SFSG had poor outcome and prognosis, especially when it accompanies the surgical infectious complications with preoperative high PELD/MELD scores.


Assuntos
Hepatopatias/cirurgia , Transplante de Fígado/métodos , Fígado/anatomia & histologia , Fígado/cirurgia , Doadores Vivos , Adolescente , Criança , Feminino , Sobrevivência de Enxerto , Humanos , Masculino , Tamanho do Órgão , Seleção de Pacientes , Estudos Retrospectivos , Fatores de Risco
20.
Talanta ; 275: 126137, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38677163

RESUMO

The present research is focused on the proposal of use of flow-modulation comprehensive two-dimensional enantio-gas chromatography (FM eGC × GC) as a valid, flexible, and possibly superior alternative to heart-cutting multidimensional enantio-GC (eMDGC). The latter, a technique of demonstrated utility, is used specifically for the targeted separation of chiral compounds, whereas FM eGC × GC can produce both targeted and high-resolution untargeted information in a single run. It is clearly possible to use eMDGC for untargeted analysis, often with a flame ionization detector (stand-by analysis), to monitor a first-dimension (1D) separation, of much lower peak capacity compared to FM eGC × GC. If eMDGC is used with mass spectrometry (MS), it is normally exploited to monitor the second-dimension (2D) separation. The analytical instrument consisted of automated solid-phase microextraction (SPME), and a low duty-cycle FM eGC × GC system (with time-of-flight MS), equipped with an enantioselective 1D column (2,3-di-O-methyl-6-t-butyl silyl ß-cyclodextrin derivative) and a 2D polyethylene glycol one. Ten Marsala wines were subjected to analysis, for the determination of chiral lactones (many at the low ppb level, due to the high concentration capacity of SPME) and for general analyte profiling. In many instances, highly complex chromatograms were attained, with statistical analysis (ANOVA-simultaneous component analysis and partial least squares discriminant analysis) used for sample differentiation.