Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 555
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Nano Lett ; 24(13): 3890-3897, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38526426

RESUMO

Chemical reaction kinetics at the nanoscale are intertwined with heterogeneity in structure and composition. However, mapping such heterogeneity in a liquid environment is extremely challenging. Here we integrate graphene liquid cell (GLC) transmission electron microscopy and four-dimensional scanning transmission electron microscopy to image the etching dynamics of gold nanorods in the reaction media. Critical to our experiment is the small liquid thickness in a GLC that allows the collection of high-quality electron diffraction patterns at low dose conditions. Machine learning-based data-mining of the diffraction patterns maps the three-dimensional nanocrystal orientation, groups spatial domains of various species in the GLC, and identifies newly generated nanocrystallites during reaction, offering a comprehensive understanding on the reaction mechanism inside a nanoenvironment. This work opens opportunities in probing the interplay of structural properties such as phase and strain with solution-phase reaction dynamics, which is important for applications in catalysis, energy storage, and self-assembly.

2.
Nano Lett ; 24(10): 2998-3004, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38319977

RESUMO

Transition metal oxide dielectric layers have emerged as promising candidates for various relevant applications, such as supercapacitors or memory applications. However, the performance and reliability of these devices can critically depend on their microstructure, which can be strongly influenced by thermal processing and substrate-induced strain. To gain a more in-depth understanding of the microstructural changes, we conducted in situ transmission electron microscopy (TEM) studies of amorphous HfO2 dielectric layers grown on highly textured (111) substrates. Our results indicate that the minimum required phase transition temperature is 180 °C and that the developed crystallinity is affected by texture transfer. Using in situ TEM and 4D-STEM can provide valuable insights into the fundamental mechanisms underlying the microstructural evolution of dielectric layers and could pave the way for the development of more reliable and efficient devices for future applications.

3.
J Comput Chem ; 45(11): 738-751, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38112413

RESUMO

Elucidating protein conformational changes is essential because conformational changes are closely related to the functions of proteins. Cryo-electron microscopy (cryo-EM) experiment can be used to reconstruct protein conformational changes via a method that involves using the experimental data (two-dimensional protein images). In this study, a reconstruction method, referred to as the "four-dimensional imaging," was proposed. In our four-dimensional imaging technique, the protein conformational change was obtained using the two-dimensional protein images (the three-dimensional electron density maps used in previously proposed techniques were not used). The protein conformation for each two-dimensional protein image was obtained using our original protocol with molecular dynamics simulations. Using a manifold-learning technique and two-dimensional protein images, the protein conformations were arranged according to the conformational change of the protein. By arranging the protein conformations according to the arrangement of the protein images, four-dimensional imaging is constructed. A simulation for a cryo-EM experiment demonstrated the validity of our four-dimensional imaging technique.


Assuntos
Simulação de Dinâmica Molecular , Proteínas , Microscopia Crioeletrônica/métodos , Conformação Proteica
4.
Artigo em Inglês | MEDLINE | ID: mdl-39319519

RESUMO

INTRODUCTION: Left atrial appendage occlusion (LAAO) can be performed using diverse anesthetic approaches ranging from moderate sedation (MS) to general anesthesia (GA), and guided by intracardiac echocardiography (ICE) or transesophageal echocardiography (TEE). Prior studies have demonstrated shorter time in lab for heart rhythm procedures performed under MS. The objective of this study was to compare laboratory times, acute procedural outcomes and complication rates for LAAO procedures performed using MS and 4-dimensional ICE as opposed to GA. METHODS AND RESULTS: This was a retrospective observational cohort study of 135 consecutive patients who were referred for LAAO to be performed with either GA or MS between June 2022 and April 2024. The primary endpoints were total laboratory time, procedure time, nonprocedure time, and fluoroscopy time. The secondary endpoints were stroke, peri-device leak (>5 mm), device-related left atrial thrombus, cardiovascular mortality, and all-cause mortality at 45 days and 6 months postprocedure, where data were available. The mean age of patients in the study was 78.8 ± 7.8 years and 64.4% were male with no difference between GA and MS. In the MS group, 4D-ICE was used for intraprocedural imaging in 95.5% of patients and 2 dimensional-ICE (2D-ICE) was used in 4.5% of patients. In the GA group, intra-procedural imaging was done using TEE in 51.5%, 2D-ICE in 32.4% and 4D-ICE in 16.2% of cases. Total laboratory time was significantly lower in the MS group compared to the GA group (68.3 ± 23.1 vs 117.1 ± 34.3 min; p < 0.001), due to shorter nonprocedure time (15.2 ± 9.1 vs 63.7 ± 22.0 min; p < 0.001), with no significant difference in procedure time and fluoroscopy time. There was no significant difference in complications at 45 days and 6 months postprocedure. CONCLUSION: In this single center study, MS reduced total lab time by reducing nonprocedure time when compared to GA for LAAO, without affecting clinical outcomes.

5.
J Magn Reson Imaging ; 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38520716

RESUMO

BACKGROUND: Liver fibrosis (LF) precipitates systemic hemodynamic alterations, however, its impact on the aorta remaining undefined. PURPOSE: To assess aorta hemodynamics changes during LF development in a rabbit model. STUDY TYPE: Prospective, experimental. ANIMAL MODEL: Thirty 7-month-old male rabbits underwent bile duct ligation (BDL) to induce LF. FIELD STRENGTH/SEQUENCE: Biweekly four-dimensional (4D) flow imaging incorporating a 3D gradient-echo at 3.0 T scanner for 14 weeks post-BDL. ASSESSMENT: Histopathological exams for 2-5 rabbits were performed at each time point, following each MRI scan. LF was graded using the Metavir scale by a pathologist. 4D flow was analyzed by two radiologists using dedicated postprocessing software. They recorded 4D flow parameters at four aorta sections (aortic sinus, before and after bifurcation of aortic arch, and descending aorta). STATISTICAL TESTS: The linear mixed model; Bonferroni correction; Pearson correlation coefficient (r); receiver operating characteristic (ROC) curve; Delong test. The level of significance was set at P < 0.05. RESULTS: Following BDL, the wall shear stress (WSS) (0.23-0.32 Pa), energy loss (EL) (0.27-1.55 mW) of aorta significantly increased at the second week for each plane, peaking at the sixth week (WSS: 0.35-0.49 Pa, EL: 0.57-2.0 mW). So did the relative pressure difference (RPD) (second week: 1.67 ± 1.63 mmHg, sixth week: 2.43 ± 0.63 mmHg) in plane 2. Notably, the RPD in plane 2 at the second week displayed the highest area under ROC curve of 0.998 (specificity: 1, sensitivity: 0.967). LF were found at the second, fourth, and sixth week after BDL, with grade F2, F3, and F4, respectively. The RPD in plane 2 was most strongly correlated with the severity of LF (r = 0.86). DATA CONCLUSIONS: The occurrence of LF could increase WSS, EL, and RPD of aorta as early as the second week following BDL. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 2.

6.
Eur Radiol ; 34(4): 2152-2167, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37728778

RESUMO

OBJECTIVES: CT perfusion (CTP) has been suggested to increase the rate of large vessel occlusion (LVO) detection in patients suspected of acute ischemic stroke (AIS) if used in addition to a standard diagnostic imaging regime of CT angiography (CTA) and non-contrast CT (NCCT). The aim of this study was to estimate the costs and health effects of additional CTP for endovascular treatment (EVT)-eligible occlusion detection using model-based analyses. METHODS: In this Dutch, nationwide retrospective cohort study with model-based health economic evaluation, data from 701 EVT-treated patients with available CTP results were included (January 2018-March 2022; trialregister.nl:NL7974). We compared a cohort undergoing NCCT, CTA, and CTP (NCCT + CTA + CTP) with a generated counterfactual where NCCT and CTA (NCCT + CTA) was used for LVO detection. The NCCT + CTA strategy was simulated using diagnostic accuracy values and EVT effects from the literature. A Markov model was used to simulate 10-year follow-up. We adopted a healthcare payer perspective for costs in euros and health gains in quality-adjusted life years (QALYs). The primary outcome was the net monetary benefit (NMB) at a willingness to pay of €80,000; secondary outcomes were the difference between LVO detection strategies in QALYs (ΔQALY) and costs (ΔCosts) per LVO patient. RESULTS: We included 701 patients (median age: 72, IQR: [62-81]) years). Per LVO patient, CTP-based occlusion detection resulted in cost savings (ΔCosts median: € - 2671, IQR: [€ - 4721; € - 731]), a health gain (ΔQALY median: 0.073, IQR: [0.044; 0.104]), and a positive NMB (median: €8436, IQR: [5565; 11,876]) per LVO patient. CONCLUSION: CTP-based screening of suspected stroke patients for an endovascular treatment eligible large vessel occlusion was cost-effective. CLINICAL RELEVANCE STATEMENT: Although CTP-based patient selection for endovascular treatment has been recently suggested to result in worse patient outcomes after ischemic stroke, an alternative CTP-based screening for endovascular treatable occlusions is cost-effective. KEY POINTS: • Using CT perfusion to detect an endovascular treatment-eligible occlusions resulted in a health gain and cost savings during 10 years of follow-up. • Depending on the screening costs related to the number of patients needed to image with CT perfusion, cost savings could be considerable (median: € - 3857, IQR: [€ - 5907; € - 1916] per patient). • As the gain in quality adjusted life years was most affected by the sensitivity of CT perfusion-based occlusion detection, additional studies for the diagnostic accuracy of CT perfusion for occlusion detection are required.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Idoso , AVC Isquêmico/diagnóstico por imagem , AVC Isquêmico/terapia , Análise Custo-Benefício , Estudos Retrospectivos , Angiografia por Tomografia Computadorizada/métodos , Tomografia Computadorizada por Raios X/métodos , Perfusão , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia , Isquemia Encefálica/terapia , Isquemia Encefálica/tratamento farmacológico , Trombectomia
7.
Eur Radiol ; 34(2): 797-807, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37572189

RESUMO

OBJECTIVES: We aimed to evaluate the real-world variation in CT perfusion (CTP) imaging protocols among stroke centers and to explore the potential for standardizing vendor software to harmonize CTP images. METHODS: Stroke centers participating in a nationwide multicenter healthcare evaluation were requested to share their CTP scan and processing protocol. The impact of these protocols on CTP imaging was assessed by analyzing data from an anthropomorphic phantom with center-specific vendor software with default settings from one of three vendors (A-C): IntelliSpace Portal, syngoVIA, and Vitrea. Additionally, standardized infarct maps were obtained using a logistic model. RESULTS: Eighteen scan protocols were studied, all varying in acquisition settings. Of these protocols, seven, eight, and three were analyzed with center-specific vendor software A, B, and C respectively. The perfusion maps were visually dissimilar between the vendor software but were relatively unaffected by the acquisition settings. The median error [interquartile range] of the infarct core volumes (mL) estimated by the vendor software was - 2.5 [6.5] (A)/ - 18.2 [1.2] (B)/ - 8.0 [1.4] (C) when compared to the ground truth of the phantom (where a positive error indicates overestimation). Taken together, the median error [interquartile range] of the infarct core volumes (mL) was - 8.2 [14.6] before standardization and - 3.1 [2.5] after standardization. CONCLUSIONS: CTP imaging protocols varied substantially across different stroke centers, with the perfusion software being the primary source of differences in CTP images. Standardizing the estimation of ischemic regions harmonized these CTP images to a degree. CLINICAL RELEVANCE STATEMENT: The center that a stroke patient is admitted to can influence the patient's diagnosis extensively. Standardizing vendor software for CT perfusion imaging can improve the consistency and accuracy of results, enabling a more reliable diagnosis and treatment decision. KEY POINTS: • CT perfusion imaging is widely used for stroke evaluation, but variation in the acquisition and processing protocols between centers could cause varying patient diagnoses. • Variation in CT perfusion imaging mainly arises from differences in vendor software rather than acquisition settings, but these differences can be reconciled by standardizing the estimation of ischemic regions. • Standardizing the estimation of ischemic regions can improve CT perfusion imaging for stroke evaluation by facilitating reliable evaluations independent of the admission center.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Humanos , Isquemia Encefálica/terapia , Acidente Vascular Cerebral/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Imagem de Perfusão/métodos , Infarto , Perfusão
8.
Environ Sci Technol ; 58(20): 8919-8931, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38709668

RESUMO

For the first time, we present a much-needed technology for the in situ and real-time detection of nanoplastics in aquatic systems. We show an artificial intelligence-assisted nanodigital in-line holographic microscopy (AI-assisted nano-DIHM) that automatically classifies nano- and microplastics simultaneously from nonplastic particles within milliseconds in stationary and dynamic natural waters, without sample preparation. AI-assisted nano-DIHM identifies 2 and 1% of waterborne particles as nano/microplastics in Lake Ontario and the Saint Lawrence River, respectively. Nano-DIHM provides physicochemical properties of single particles or clusters of nano/microplastics, including size, shape, optical phase, perimeter, surface area, roughness, and edge gradient. It distinguishes nano/microplastics from mixtures of organics, inorganics, biological particles, and coated heterogeneous clusters. This technology allows 4D tracking and 3D structural and spatial study of waterborne nano/microplastics. Independent transmission electron microscopy, mass spectrometry, and nanoparticle tracking analysis validates nano-DIHM data. Complementary modeling demonstrates nano- and microplastics have significantly distinct distribution patterns in water, which affect their transport and fate, rendering nano-DIHM a powerful tool for accurate nano/microplastic life-cycle analysis and hotspot remediation.


Assuntos
Inteligência Artificial , Microplásticos , Poluentes Químicos da Água/química , Poluentes Químicos da Água/análise , Monitoramento Ambiental/métodos , Água/química
9.
Sleep Breath ; 28(2): 597-606, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38127191

RESUMO

AIM-BACKGROUND: In the treatment of obstructive sleep apnoea (OSA), oral appliances are now being recognized as a valuable alternative to continuous positive airway pressure (CPAP). Various static imaging techniques of the upper airways allow for assessment of bone and soft tissue structures. However, static images do not capture dynamic airway characteristics. The aim of this paper was to review 4D imaging techniques in patients with OSA. METHODS: PubMed/MEDLINE, Web of Science and Embase were systematically searched for studies published before June 2022. The review was compliant with the PRISMA guidelines. The quality of each eligible study was critically evaluated by all four authors independently. Four unique articles with qualitative analyses were retrieved. All included studies had a clear objective/aim, an appropriate endpoint and sufficiently described eligibility criteria. RESULTS: With dynamic imaging (4D) evaluation of the upper airway, the incidence of upper airway collapsibility due to use of a mandibular advancement device (MAD) was reduced, extraluminal tissue pressure was decreased and the space in the upper airway was increased, notably in the retropalatal and retroglossal areas of the airway. These findings suggest that MADs may be effective for OSA regardless of whether or not the obstruction site is in the velopharynx or oropharynx. However, further investigation of dynamic changes in the upper airway is required to explain the efficacy of OSA treatment and the underlying mechanisms.


Assuntos
Sistema Respiratório , Apneia Obstrutiva do Sono , Humanos , Avanço Mandibular/instrumentação , Apneia Obstrutiva do Sono/terapia , Apneia Obstrutiva do Sono/diagnóstico por imagem , Sistema Respiratório/diagnóstico por imagem
10.
Pediatr Cardiol ; 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38809278

RESUMO

Current study aims to compare the application of two-dimensional (2D) color doppler ultrasound (CDU) and four-dimensional (4D) ultrasound spatiotemporal image correlation (STIC) in fetal congenital heart disease in the second trimester of pregnancy and to analyze the high risk factors of the disease. From August 2019 to July 2021, 135 second-trimester patients with highly suspected congenital heart malformations were selected who underwent prenatal screening at South Taihu Hospital Affiliated to Huzhou University. 2D-CDU, 4D STIC, and postnatal examination were completed in all patients. 2D-CDU, 4D STIC and 2D-CDU combined with 4D STIC were used to detect fetal cardiac malformations and classify cardiac malformations. The sensitivity, specificity, positive predictive value, negative predictive value and coincidence rate of 2D-CDU, 4D STIC and 2D-CDU combined with 4D STIC were compared. The results of 2D-CDU, 4D STIC and 2D-CDU combined with 4D STIC screening were analyzed for consistency using the results of postpartum diagnosis as the gold standard. Moreover, effects of maternal gestational factors on fetal cardiac malformations by univariate and multivariate analysis. 2D-CDU combined with 4D STIC showed significantly higher section display number than 2D-CDU or 4D STIC in the view of ductal arch, aortic arch, and aortic short-axis. A total of 45 cases of fetal congenital heart malformation were detected in 135 patients in the second trimester, 40, 38 or 42 cases were detected by 2D-CDU, 4D STIC or 2D-CDU combined with 4D STIC, respectively. The sensitivity, specificity, positive predictive value, negative predictive value and coincidence rate of 2D-CDU combined with 4D ultrasound in congenital heart malformation screening were higher than those of 2D-CDU or 4D STIC. Kappa agreement analysis showed that the diagnostic results of 4D STIC and 2D-CDU combined with 4D ultrasound in fetuses with suspected congenital heart malformation were in excellent agreement (κ > 0.75), while 2D-CDU was in good agreement with postpartum diagnosis (κ < 0.75). Univariate and multivariate regression analysis revealed that maternal age ≥ 35, drinking during pregnancy, and history of adverse pregnancy and childbirth were all independent risk factors for fetal cardiac malformations, while folic acid supplementation was an independent protective factor for fetal cardiac malformations. 2D-CDU combined with 4D echocardiography may be superior to single 2D-CDU or 4D STIC in the screening of fetal congenital heart malformation in the second trimester. In order to reduce the incidence of fetal heart anomalies, we should strengthen the screening of pregnancy anomalies in high-risk pregnant women and control the risk factors.

11.
J Appl Clin Med Phys ; : e14532, 2024 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-39284228

RESUMO

BACKGROUND: Stereotactic ablative body radiation (SABR) is a well-recognized treatment option for hepatocellular carcinoma (HCC). Due to the inherent motion of liver tumors, effective motion management is crucial for successful SABR. In the motion-encompassing motion management technique, all 10 respiratory phase image datasets are delineated and designated as the internal target volume (ITV). Some treatment centers use single or combination image sets to delineate the target volume. This study determines which specialty image set most closely matches an all-phase ITV contour on a synchronized contrast-enhanced 4DCT. MATERIALS AND METHODS: Synchronized 4DCT contrast and delayed scans were acquired for 10 patients in the study. The maximum intensity projection (MiP), average intensity projection (AvgIP), and minimum intensity projection (MinIP) images were generated. The ITV delineation was done in all 10 phases (ITV_all_phase). The ITV_2phase combines the peak inhale and exhale phase, ITV_2 M combines MiP and MinIP, and ITV_3 M combines MiP, MinIP, and AvgIP. All ITVs were compared to ITV_all_phase with Dice similarity index (DSI) and volumes. RESULTS: Using ITV_all_phase as the reference, the DSI and the mean ITV volumes for the different ITVs were as follows: ITV_all_phase (1 and 116.69 cc), ITV_2phase (0.87 and 105.27 cc), MiP (0.76 and 98.24 cc), AvgIP (0.72 and 94.54 cc), ITV_MinIP (0.67 and 81.08 cc), ITV_2 M (0.84 and 106.26 cc), and ITV_3 M (0.86 and 112.51 cc). CONCLUSION: The study demonstrates that in the motion-encompassing technique of motion management, the target volume generated by delineating all phases of 4DCT provides the most accurate representation for patients with HCC. Specialty image sets and their combinations, while sometimes close, tend to result in less accurate targeting. Hence, the all-phase 4DCT method should be preferred to avoid geographical misses and ensure optimal treatment outcomes. However, our conclusion may be limited by the technique we employed.

12.
J Oral Rehabil ; 51(2): 359-368, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37775500

RESUMO

BACKGROUND: Recently, recommendations were given for a new scoring of the Oral Health Impact Profile (OHIP). The original seven domain structure should be replaced by a four-dimensional scale. OBJECTIVES: To investigate the effect of dental prosthetic treatment on the seven domains and the four-dimensional scale of the OHIP-G49/53 questionnaire. METHODS: Seventy four patients were grouped according their pre- and post-treatment situation and the type of treatment they received. Patients completed the OHIP-G49/53 questionnaire before prosthetic treatment (T0), and at 1 week (T1), 3 months (T2) and 6 months (T3) after treatment. Treatment effects on the seven domains and the four dimensions of the OHIP scale were analysed, and the oral health-related quality of life (OHRQoL) was measured. Patients' expectations of their prosthetic treatment were also evaluated. Data were analysed using two-way Mixed ANOVA, regression analysis, and Cronbach's alpha test with a level of significance of α ≤ .017. RESULTS: OHRQoL significantly improved following prosthetic treatment compared with baseline. The largest improvement was found between T0 and T1 evaluations (all p ≤ .001). Unlike the seven-domain scale, the four OHIP dimensions demonstrated further significant improvements across the T1/T2/T3 evaluations (all p ≤ .017). Different pre-treatment findings had different treatment effects on the four OHIP dimensions and seven OHIP domains. Patients' expectations were mainly fulfilled. CONCLUSION: Compared with the seven-domain scale, the four dimensions showed significant follow-up changes, suggesting the four dimensions are suitable for evaluating treatment effects up to 6 months. Clinically meaningful effects of dental prosthetic treatment can be sensitively measured using the four-dimensional OHIP scale.


Assuntos
Saúde Bucal , Qualidade de Vida , Humanos , Motivação , Inquéritos e Questionários
13.
J Proteome Res ; 22(3): 908-918, 2023 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-36648763

RESUMO

Peritoneal fibrosis progression is regarded as a significant cause of the loss of peritoneal function, markedly limiting the application of peritoneal dialysis (PD). However, the pathogenesis of peritoneal fibrosis remains to be elucidated. Tissue-derived extracellular vesicles (EVs) change their molecular cargos to adapt the environment alteration, mediating intercellular communications and play a significant role in organ fibrosis. Hence, we performed, for the first time, four-dimensional label-free quantitative liquid chromatography-tandem mass spectrometry proteomic analyses on EVs from normal peritoneal tissues and PD-induced fibrotic peritoneum in mice. We demonstrated the alterations of EV concentration and protein composition between normal control and PD groups. A total of 2339 proteins containing 967 differentially expressed proteins were identified. Notably, upregulated proteins in PD EVs were enriched in processes including response to wounding and leukocyte migration, which participated in the development of fibrosis. In addition, EV proteins of the PD group exhibited unique metabolic signature compared with those of the control group. The glycolysis-related proteins increased in PD EVs, while oxidative phosphorylation and fatty acid metabolism-related proteins decreased. We also evaluated the effect of cell-type specificity on EV proteins, suggesting that mesothelial cells mainly cause the alterations in the molecular composition of EVs. Our study provided a useful resource for further validation of the key regulator or therapeutic target of peritoneal fibrosis.


Assuntos
Vesículas Extracelulares , Diálise Peritoneal , Fibrose Peritoneal , Camundongos , Animais , Peritônio/metabolismo , Peritônio/patologia , Fibrose Peritoneal/metabolismo , Fibrose Peritoneal/patologia , Fibrose Peritoneal/terapia , Proteômica/métodos , Diálise Peritoneal/efeitos adversos , Diálise Peritoneal/métodos , Vesículas Extracelulares/patologia
14.
Am J Physiol Heart Circ Physiol ; 325(2): H293-H310, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37326999

RESUMO

The comprehensive characterization of cardiac structure and function is critical to better understanding various murine models of cardiac disease. We demonstrate here a multimodal analysis approach using high-frequency four-dimensional ultrasound (4DUS) imaging and proteomics to explore the relationship between regional function and tissue composition in a murine model of metabolic cardiomyopathy (Nkx2-5183P/+). The presented 4DUS analysis outlines a novel approach to mapping both circumferential and longitudinal strain profiles through a standardized framework. We then demonstrate how this approach allows for spatiotemporal comparisons of cardiac function and improved localization of regional left ventricular dysfunction. Guided by observed trends in regional dysfunction, our targeted Ingenuity Pathway Analysis (IPA) results highlight metabolic dysregulation in the Nkx2-5183P/+ model, including altered mitochondrial function and energy metabolism (i.e., oxidative phosphorylation and fatty acid/lipid handling). Finally, we present a combined 4DUS-proteomics z-score-based analysis that highlights IPA canonical pathways showing strong linear relationships with 4DUS biomarkers of regional cardiac dysfunction. The presented multimodal analysis methods aim to help future studies more comprehensively assess regional structure-function relationships in other preclinical models of cardiomyopathy.NEW & NOTEWORTHY A multimodal approach using both four-dimensional ultrasound (4DUS) and regional proteomics can help enhance our investigations of murine cardiomyopathy models. We present unique 4DUS-derived strain maps that provide a framework for both cross-sectional and longitudinal analysis of spatiotemporal cardiac function. We further detail and demonstrate an innovative 4DUS-proteomics z-score-based linear regression method, aimed at characterizing relationships between regional cardiac dysfunction and underlying mechanisms of disease.


Assuntos
Cardiomiopatias , Disfunção Ventricular Esquerda , Masculino , Animais , Camundongos , Estudos Transversais , Proteômica , Ultrassonografia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Proteína Homeobox Nkx-2.5
15.
Small ; 19(2): e2204630, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36382576

RESUMO

Biomimetic stimuli-responsive structure colors (SCs) can improve the visualization and identification in the micro functional structure field such as information encryption/decryption and smart actuators. However, it is still challenging to develop the ability to 4D print arbitrary submerged colorful patterns with stimuli-responsive materials at the microscale. Herein, a hydrogel photoresist with feature resolution (98 nm) for the fabrication of 4D microscopic SCs by the femtosecond direct laser writing method is developed. The 4D printed woodpile SCs are grouped as pixel palettes with various laser parameters and they spanned almost the entire color space. The coloring mechanism of diffraction gratings is not only investigated by optics microscopy and spectroscopy but also supported by simulation. Moreover, the 4D printed hydrogel-integrated amphichromatic fish constructions and pixelated painting can visually discolor reversibly by regulating the solution pH. This finding promises an ideal coloring method for sensors, anti-counterfeiting labels, and transformable photonic devices.


Assuntos
Luz , Fótons , Animais , Hidrogéis/química , Óptica e Fotônica , Lasers
16.
Strahlenther Onkol ; 199(5): 465-476, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36477250

RESUMO

PURPOSE: Stereotactic body radiotherapy (SBRT) is a treatment option for early-stage lung cancer. We aimed to examine the differences in failure patterns after SBRT according to the clinical T stage. METHODS: A total of 120 patients with early-stage lung cancer (T1-3N0M0) who underwent SBRT were analysed. The clinical stage in patients whose tumours were in contact with the chest wall was confirmed using four-dimensional computed tomography (4D-CT). Local failure, regional node metastasis, and distant metastasis were confirmed from clinical charts. RESULTS: Median follow-up time was 27.5 months (range 7-122) after SBRT. Thirteen patients were restaged from clinical T2 with visceral pleural invasion to T3 with chest wall invasion using 4D-CT analysis. Thirty-seven patients developed recurrences. The median progression-free survival (PFS) and overall survival (OS) were 38.1 and 53.8 months, respectively. The 3­year PFS and OS rates were 50.7% and 60.3%, respectively. A significant difference was observed in PFS according to the clinical T stage (p = 0.001). No significant differences were observed in OS according to the clinical T stage (p = 0.213). The proportion of locoregional failures relative to distant metastasis decreased with progression from T1 to T3. The pleural dissemination rate was significantly higher in T3 tumours than in T1 and T2 tumours (p = 0.010). CONCLUSION: Clinical T stage is associated with PFS after SBRT for lung cancer. There were differences in the failure patterns according to T stage. 4D-CT might provide significant information for assessing chest wall invasion associated with unfavourable PFS.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Humanos , Tomografia Computadorizada Quadridimensional , Radiocirurgia/métodos , Resultado do Tratamento , Estudos Retrospectivos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia
17.
Strahlenther Onkol ; 199(5): 445-455, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36331584

RESUMO

BACKGROUND: 4DCT (four-dimensional computed tomography) can effectively obtain functional lung ventilation images for patients and integrate them into radiotherapy treatment planning. Studies have not been performed on esophageal cancer, and there is no clear consensus on the optimal functional lung threshold for functional lung. METHODS: Functional lung images were generated for 11 patients with esophageal cancer. The correlation between the dose-volume parameters of functional lung (FL) as defined by different thresholds and the change of PFT/PDFT (pulmonary [diffusion] function test) metrics before and after radiotherapy were evaluated. FL-sparing planning was generated for each patient to preserve the functional lung and compared to conventional anatomical CT (non-sparing) planning. RESULTS: There was a significant positive correlation between the FL0.8 (defined Jacobian value ≤ 0.8), FL0.84, and FL0.9 dose-volume parameters and ΔFEV1/FVC (reduction before and after radiotherapy), and the FL0.8­V30 correlation was the strongest (r = 0.819, P < 0.01). The FL-sparing planning had a target area conformity index and homogeneity index comparable to the non-sparing planning (P > 0.05). For FL, the FL-sparing planning achieved lower FL-MLD (6.30 ±â€¯2.14 Gy vs. 7.83 ± 2.70 Gy), V10 (17.13 ±â€¯7.70% vs. 27.40 ± 9.48%), and V20 (6.96 ±â€¯3.85% vs. 11.63 ± 7.19%) compared to the non-sparing planning (P < 0.05), while heart and spinal cord doses were not significantly different between the two planning groups. CONCLUSION: The 4DCT-based FL irradiation dose for esophageal cancer was significantly associated with a decrease in FEV1/FVC. The optimal FL defined as a Jacobian value ≤ 0.8 or about 21% of the whole lung volume may be a good choice. FL-sparing planning significantly reduced the FL dose without compromising target area coverage.


Assuntos
Neoplasias Esofágicas , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Tomografia Computadorizada Quadridimensional/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Pulmão/efeitos da radiação , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/radioterapia , Dosagem Radioterapêutica
18.
J Magn Reson Imaging ; 57(1): 71-82, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35726779

RESUMO

BACKGROUND: Neonates with critical congenital heart disease require early intervention. Four-dimensional (4D) flow may facilitate surgical planning and improve outcome, but accuracy and precision in neonates are unknown. PURPOSE: To 1) validate two-dimensional (2D) and 4D flow MRI in a phantom and investigate the effect of spatial and temporal resolution; 2) investigate accuracy and precision of 4D flow and internal consistency of 2D and 4D flow in neonates; and 3) compare scan time of 4D flow to multiple 2D flows. STUDY TYPE: Phantom and prospective patients. POPULATION: A total of 17 neonates with surgically corrected aortic coarctation (age 18 days [IQR 11-20]) and a three-dimensional printed neonatal aorta phantom. FIELD STRENGTH/SEQUENCE: 1.5T, 2D flow and 4D flow. ASSESSMENT: In the phantom, 2D and 4D flow volumes (ascending and descending aorta, and aortic arch vessels) with different resolutions were compared to high-resolution reference 2D flow. In neonates, 4D flow was compared to 2D flow volumes at each vessel. Internal consistency was computed as the flow volume in the ascending aorta minus the sum of flow volumes in the aortic arch vessels and descending aorta, divided by ascending aortic flow. STATISTICAL TESTS: Bland-Altman plots, Pearson correlation coefficient (r), and Student's t-tests. RESULTS: In the phantom, 2D flow differed by 0.01 ± 0.02 liter/min with 1.5 mm spatial resolution and -0.01 ± 0.02 liter/min with 0.8 mm resolution; 4D flow differed by -0.05 ± 0.02 liter/min with 2.4 mm spatial and 42 msec temporal resolution, -0.01 ± 0.02 liter/min with 1.5 mm, 42 msec resolution and -0.01 ± 0.02 liter/min with 1.5 mm, 21 msec resolution. In patients, 4D flow and 2D flow differed by -0.06 ± 0.08 liter/min. Internal consistency in patients was -11% ± 17% for 2D flow and 5% ± 13% for 4D flow. Scan time was 17.1 minutes [IQR 15.5-18.5] for 2D flow and 6.2 minutes [IQR 5.3-6.9] for 4D flow, P < 0.0001. DATA CONCLUSION: Neonatal 4D flow MRI is time efficient and can be acquired with good internal consistency without contrast agents or general anesthesia, thus potentially expanding 4D flow use to the youngest and smallest patients. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Recém-Nascido , Humanos , Adolescente , Imageamento Tridimensional/métodos , Velocidade do Fluxo Sanguíneo , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Anestesia Geral , Reprodutibilidade dos Testes
19.
J Magn Reson Imaging ; 2023 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-38006298

RESUMO

BACKGROUND: Maximum diameter measurements are used to assess the rupture risk of abdominal aortic aneurysms (AAAs); however, these are not precise enough to predict all ruptures. Four-dimensional (4D) flow MRI-derived parameters provide additional information by visualizing hemodynamics in AAAs but merit further investigation before they are clinically applicable. PURPOSE: To assess the reproducibility of 4D flow MRI-derived hemodynamics, to investigate possible correlations with lumen and maximum diameter, and to explore potential relationships with vorticity and aneurysm growth. STUDY TYPE: Prospective single-arm study. POPULATION: A total of 22 (71.5 ± 6.1 years, 20 male) asymptomatic AAA patients with a maximum diameter of at least 30 mm. FIELD STRENGTH/SEQUENCE: A 3.0 T/Free-breathing 4D flow MRI phase-contrast acquisition with retrospective ECG-gating. ASSESSMENT: Patients underwent two consecutive 4D flow MRI scans 1-week apart. Aortic volumes were segmented from time-averaged phase contrast magnetic resonance angiographies. Reproducibility was assessed by voxelwise analysis after registration. Mean flow velocity, mean wall shear stress (WSS), mean lumen diameter, and qualitative vorticity scores were assessed. In addition, Dixon MRI and retrospective surveillance data were used to study maximum diameter (including thrombus), intraluminal thrombus volume (ILT), and growth rate. STATISTICAL TESTS: For reproducibility assessment, Bland-Altman analyses, Pearson correlation, Spearman's correlation, and orthogonal regression were conducted. Potential correlations between hemodynamics and vorticity scores were assessed using linear regression. P < 0.05 was considered statistically significant. RESULTS: Test-retest median Pearson correlation coefficients for flow velocity and WSS were 0.85 (IQR = 0.08) m/sec and 0.82 (IQR = 0.10) Pa, respectively. Mean WSS significantly correlated with mean flow velocity (R = 0.75) and inversely correlated with mean lumen diameter (R = -0.73). No significant associations were found between 4D flow MRI-derived hemodynamic parameters and maximum diameter (flow velocity: P = 0.98, WSS: P = 0.22). DATA CONCLUSION: A 4D flow MRI is robust for assessing the hemodynamics within AAAs. No correlations were found between hemodynamic parameters and maximum diameter, ILT volume and growth rate. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.

20.
J Cardiovasc Magn Reson ; 25(1): 60, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37880721

RESUMO

BACKGROUND: The differences in pre- and early post-procedural blood flow dynamics between the two major types of bioprosthetic valves, the balloon-expandable valve (BEV) and self-expandable valve (SEV), in patients with aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR), have not been investigated. We aimed to investigate the differences in blood flow dynamics between the BEV and SEV using four-dimensional flow cardiovascular magnetic resonance (4D flow CMR). METHODS: We prospectively examined 98 consecutive patients with severe AS who underwent TAVR between May 2018 and November 2021 (58 BEV and 40 SEV) after excluding those without CMR because of a contraindication, inadequate imaging from the analyses, or patients' refusal. CMR was performed in all participants before (median interval, 22 [interquartile range (IQR) 4-39] days) and after (median interval, 6 [IQR 3-6] days) TAVR. We compared the changes in blood flow patterns, wall shear stress (WSS), and energy loss (EL) in the ascending aorta (AAo) between the BEV and SEV using 4D flow CMR. RESULTS: The absolute reductions in helical flow and flow eccentricity were significantly higher in the SEV group compared in the BEV group after TAVR (BEV: - 0.22 ± 0.86 vs. SEV: - 0.85 ± 0.80, P < 0.001 and BEV: - 0.11 ± 0.79 vs. SEV: - 0.50 ± 0.88, P = 0.037, respectively); there were no significant differences in vortical flow between the groups. The absolute reduction of average WSS was significantly higher in the SEV group compared to the BEV group after TAVR (BEV: - 0.6 [- 2.1 to 0.5] Pa vs. SEV: - 1.8 [- 3.5 to - 0.8] Pa, P = 0.006). The systolic EL in the AAo significantly decreased after TAVR in both the groups, while the absolute reduction was comparable between the groups. CONCLUSIONS: Helical flow, flow eccentricity, and average WSS in the AAo were significantly decreased after SEV implantation compared to BEV implantation, providing functional insights for valve selection in patients with AS undergoing TAVR. Our findings offer valuable insights into blood flow dynamics, aiding in the selection of valves for patients with AS undergoing TAVR. Further larger-scale studies are warranted to confirm the prognostic significance of hemodynamic changes in these patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valor Preditivo dos Testes , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA