Int J Mol Sci ; 24(8)2023 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-37108506

RESUMO

Presbyopia is an age-related vision disorder that is a global public health problem. Up to 85% of people aged ≥40 years develop presbyopia. In 2015, 1.8 billion people globally had presbyopia. Of those with significant near vision disabilities due to uncorrected presbyopia, 94% live in developing countries. Presbyopia is undercorrected in many countries, with reading glasses available for only 6-45% of patients living in developing countries. The high prevalence of uncorrected presbyopia in these parts of the world is due to the lack of adequate diagnosis and affordable treatment. The formation of advanced glycation end products (AGEs) is a non-enzymatic process known as the Maillard reaction. The accumulation of AGEs in the lens contributes to lens aging (leading to presbyopia and cataract formation). Non-enzymatic lens protein glycation induces the gradual accumulation of AGEs in aging lenses. AGE-reducing compounds may be effective at preventing and treating AGE-related processes. Fructosyl-amino acid oxidase (FAOD) is active on both fructosyl lysine and fructosyl valine. As the crosslinks encountered in presbyopia are mainly non-disulfide bridges, and based on the positive results of deglycating enzymes in cataracts (another disease caused by glycation of lens proteins), we studied the ex vivo effects of topical FAOD treatment on the power of human lenses as a new potential non-invasive treatment for presbyopia. This study demonstrated that topical FAOD treatment resulted in an increase in lens power, which is approximately equivalent to the correction obtained by most reading glasses. The best results were obtained for the newer lenses. Simultaneously, a decrease in lens opacity was observed, which improved lens quality. We also demonstrated that topical FAOD treatment results in a breakdown of AGEs, as evidenced by gel permeation chromatography and a marked reduction in autofluorescence. This study demonstrated the therapeutic potential of topical FAOD treatment in presbyopia.


Assuntos
Catarata , Cristalino , Presbiopia , Humanos , Presbiopia/tratamento farmacológico , Envelhecimento , Catarata/tratamento farmacológico , Produtos Finais de Glicação Avançada
2.
Int J Mol Sci ; 24(10)2023 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-37240327

RESUMO

The consensus in aging is that inflammation, cellular senescence, free radicals, and epigenetics are contributing factors. Skin glycation through advanced glycation end products (AGEs) has a crucial role in aging. Additionally, it has been suggested that their presence in scars leads to elasticity loss. This manuscript reports fructosamine-3-kinase (FN3K) and fructosyl-amino acid oxidase (FAOD) in counteracting skin glycation by AGEs. Skin specimens were obtained (n = 19) and incubated with glycolaldehyde (GA) for AGE induction. FN3K and FAOD were used as monotherapy or combination therapy. Negative and positive controls were treated with phosphate-buffered saline and aminoguanidine, respectively. Autofluorescence (AF) was used to measure deglycation. An excised hypertrophic scar tissue (HTS) (n = 1) was treated. Changes in chemical bonds and elasticity were evaluated using mid-infrared spectroscopy (MIR) and skin elongation, respectively. Specimens treated with FN3K and FAOD in monotherapy achieved an average decrease of 31% and 33% in AF values, respectively. When treatments were combined, a decrease of 43% was achieved. The positive control decreased by 28%, whilst the negative control showed no difference. Elongation testing of HTS showed a significant elasticity improvement after FN3K treatment. ATR-IR spectra demonstrated differences in chemical bounds pre- versus post-treatment. FN3K and FAOD can achieve deglycation and the effects are most optimal when combined in one treatment.


Assuntos
Produtos Finais de Glicação Avançada , Fosfotransferases (Aceptor do Grupo Álcool) , Aminoácidos , Oxirredutases
3.
Molecules ; 26(3)2021 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-33572552

RESUMO

Glycated albumin (GA) is an important glycemic control marker for diabetes mellitus. This study aimed to develop a highly sensitive disposable enzyme sensor strip for GA measurement by using an interdigitated electrode (IDE) as an electrode platform. The superior characteristics of IDE were demonstrated using one microelectrode of the IDE pair as the working electrode (WE) and the other as the counter electrode, and by measuring ferrocyanide/ferricyanide redox couple. The oxidation current was immediately reached at the steady state when the oxidation potential was applied to the WE. Then, an IDE enzyme sensor strip for GA measurement was prepared. The measurement of fructosyl lysine, the protease digestion product of GA, exhibited a high, steady current immediately after potential application, revealing the highly reproducible measurement. The sensitivity (2.8 nA µM-1) and the limit of detection (1.2 µM) obtained with IDE enzyme sensor strip were superior compared with our previously reported sensor using screen printed electrode. Two GA samples, 15 or 30% GA, corresponding to healthy and diabetic levels, respectively, were measured after protease digestion with high resolution. This study demonstrated that the application of an IDE will realize the development of highly sensitive disposable-type amperometric enzyme sensors with high reproducibility.


Assuntos
Técnicas Biossensoriais/instrumentação , Equipamentos Descartáveis , Enzimas/metabolismo , Albumina Sérica/análise , Eletrodos , Produtos Finais de Glicação Avançada , Reprodutibilidade dos Testes , Albumina Sérica Glicada
4.
Anal Biochem ; 444: 47-56, 2014 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-24090871

RESUMO

The glycated hemoglobin (HbA1c) level in blood is a measure of long-term glycemic status in patients with diabetes mellitus. Current clinical methods for determination of the HbA1c level include electrophoresis/electroendosmosis, ion exchange chromatography, high-performance liquid chromatography, boronate affinity chromatography, immunoassay, and liquid chromatography-tandem mass spectroscopy in addition to fluorometry and colorimetry. These methods have certain drawbacks such as being complex, time-consuming, and requiring expensive apparatus and trained persons to operate. These drawbacks were overcome by biosensing methods. We review these biosensors, which are based on (i) measurement of electrons, that is, current generated from splitting of hydrogen peroxide released during oxidation of fructosyl valine by immobilized fructosyl amino acid oxidase, which is directly proportional to HbA1c concentration, and (ii) direct measurement of HbA1c by some specific reaction. HbA1c biosensors work optimally within 4 to 1800 s, between pH 7.0 and 9.0 and between 25 and 45 °C, and in the range of 1 to 10,000 µM, with a detection limit between 20 and 500 µM and sensitivity between 4.6 nA and 21.5 µA mM⁻¹ cm⁻² and stable over a period of 5 to 90 days. We suggest the ways to modify existing HbA1c biosensors, leading to simple, reliable, and economical sensors ideally suited for point-of-care treatment.


Assuntos
Técnicas Biossensoriais , Hemoglobinas Glicadas/análise , Humanos
5.
Biosens Bioelectron ; 89(Pt 1): 578-584, 2017 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-26897102

RESUMO

In the diabetic patients the level of glucose must be determined without any short term fluctuations. The level of Glycated hemoglobin (HbA1c) is accordingly examined for checking diabetes mellitus. HbA1c is considered one of the primarily factor to discern the concentration of average plasma glucose over a long-drawn-out period. In our work, we describe a construction of biosensor which is based on fructosyl amino-acid oxidase (FAO) immobilized nitrogen-doped graphene/gold nanoparticles (AuNPs)/fluorine doped tin oxide (FTO) glass electrode. This constructed biosensor exhibits a wide linear range of 0.3 to 2000µM in response to HbA1c at +0.2V. Consequently, the detection limit of 0.2µM and good stability (4 months) were achieved. The electrocatalytic activity of this sensor was good as a result of synergistic effect of graphene and AuNPs (2D and 0D nanomaterials). The charge transfer resistance was decreased which was observed by electrochemical impedance spectroscopy (EIS) study. The graphene/AuNPs composites film reveals a distinguished electrochemical response to fructosyl valine (FV) which demonstrates a promising application for electrochemical detection of HbA1c in human blood samples.


Assuntos
Técnicas Biossensoriais/métodos , Hemoglobinas Glicadas/análise , Ouro/química , Grafite/química , Nanoestruturas/química , Nitrogênio/química , Aminoácido Oxirredutases/química , Espectroscopia Dielétrica/métodos , Técnicas Eletroquímicas/métodos , Enzimas Imobilizadas/química , Escherichia coli/química , Escherichia coli/enzimologia , Humanos , Limite de Detecção , Nanopartículas Metálicas/química , Nanopartículas Metálicas/ultraestrutura , Modelos Moleculares , Nanoestruturas/ultraestrutura
6.
Biosens Bioelectron ; 88: 167-173, 2017 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-27522349

RESUMO

Glycated proteins, such as glycated hemoglobin (HbA1c) or glycated albumin (GA) in the blood, are essential indicators of glycemic control for diabetes mellitus. Since GA, compared to HbA1c, is more sensitive to short term changes in glycemic levels, GA is expected to be used as an alternative or together with HbA1c as a surrogate marker indicator for glycemic control. In this paper we report the development of a sensing system for measuring GA by combining an enzyme analysis method, which is already used in clinical practice, with electrochemical principles. We used fructosyl amino acid oxidase, hexaammineruthenium(III) chloride as the electron mediator, and an inexpensive and economically attractive screen-printed carbon electrode. We used chronoamperometry to measure protease-digested GA samples. The developed sensor strips were able to measure protease-digested samples containing GA in very small sample volumes (1.3µL) within about 1min. We also prepared enzyme sensor strips suitable for clinical use in which the enzyme and the mediator were deposited and dried on. This sensor system showed a clear correlation between the GA concentration and the resulting current. The strips were stable following 3 months of storage at 37°C. We conclude that this disposable enzyme sensor strip system for measuring GA is suitable for point-of-care test (POCT) applications.


Assuntos
Técnicas Biossensoriais/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Fitas Reagentes/análise , Albumina Sérica/análise , Aminoácido Oxirredutases/química , Carbono/química , Eletrodos , Desenho de Equipamento , Produtos Finais de Glicação Avançada , Humanos , Limite de Detecção , Albumina Sérica Glicada
7.
Anal Chim Acta ; 936: 83-90, 2016 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-27566342

RESUMO

A glycated hemoglobin (HbA1c) biosensor with high performance has been constructed in this work. Here the fructosyl amino acid oxidase was immobilized onto a pre-functionalized indium tin oxide glass with titania nanotubes decorated with gold nanoparticles. The property of nanocomposite was characterized by transmission electromicroscopy, scanning electron microscopy, electrochemistry and spectroscopy. Under the optimum conditions, fructosyl valine was detected by this biosensor. It exhibited a linear detection range from 4.0 × 10(-9) M to 7.2 × 10(-7) M, and a limit of detection for 3.8 × 10(-9) M at the signal-to-noise ratio of 3. Thus the HbA1c level in whole blood samples of healthy individuals or diabetic patients were evaluated with designed biosensor after pre-treatment of hydrolysis. The results of our detection were closely consistent with that of the standard method. At the same time, our biosensor has some advantages including high sensitivity, disposable usage and low cost, which implies its great promising application in point-of-care testing of HbA1c.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Hemoglobinas Glicadas/análise , Hemoglobinas/análise , Medições Luminescentes , Aminoácido Oxirredutases/química , Aminoácido Oxirredutases/metabolismo , Hemoglobinas Glicadas/metabolismo , Glicosilação , Ouro/química , Ouro/metabolismo , Hemoglobinas/metabolismo , Humanos , Nanopartículas Metálicas/química , Nanotubos/química , Titânio/química , Titânio/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA