Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
Brain Behav Immun ; 121: 303-316, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39098438

RESUMO

BACKGROUND: Cerebral Palsy (CP) is a major cause of motor and cognitive disability in children due to injury to the developing brain. Early intensive sensorimotor rehabilitation has been shown to change brain structure and reduce CP symptoms severity. We combined environmental enrichment (EE) and treadmill training (TT) to observe the effects of a one-week program of sensorimotor stimulation (EETT) in animals exposed to a CP model and explored possible mechanisms involved in the functional recovery. METHODS: Pregnant Wistar rats were injected with Lipopolysaccharide (LPS - 200 µg/kg) intraperitoneally at embryonic days 18 and 19. At P0, pups of both sexes were exposed to 20' anoxia at 37 °C. From P2 to P21, hindlimbs were restricted for 16 h/day during the dark cycle. EETT lasted from P21 to P27. TT - 15 min/day at 7 cm/s. EE - 7 days in enriched cages with sensorimotor stimulus. Functional 3D kinematic gait analysis and locomotion were analyzed. At P28, brains were collected for ex-vivo MRI and histological assessment. Neurotrophins and key proteins involved in CNS function were assessed by western blotting. RESULTS: CP model caused gross and skilled locomotor disruption and altered CNS neurochemistry. EETT reversed locomotor dysfunction with minor effects over gait kinematics. EETT also decreased brain inflammation and glial activation, preserved myelination, upregulated BDNF signaling and modulated the expression of proteins involved in excitatory synaptic function in the brain and spinal cord. CONCLUSIONS: Using this translational approach based on intensive sensorimotor rehabilitation, we highlight pathways engaged in the early developmental processes improving neurological recovery observed in CP.


Assuntos
Paralisia Cerebral , Modelos Animais de Doenças , Locomoção , Plasticidade Neuronal , Ratos Wistar , Animais , Paralisia Cerebral/reabilitação , Paralisia Cerebral/fisiopatologia , Plasticidade Neuronal/fisiologia , Ratos , Feminino , Locomoção/fisiologia , Masculino , Encéfalo/metabolismo , Encéfalo/fisiopatologia , Gravidez , Recuperação de Função Fisiológica/fisiologia , Encefalite/metabolismo , Encefalite/fisiopatologia , Encefalite/reabilitação , Marcha/fisiologia , Condicionamento Físico Animal/fisiologia , Condicionamento Físico Animal/métodos , Doenças Neuroinflamatórias/metabolismo , Doenças Neuroinflamatórias/fisiopatologia
2.
Sensors (Basel) ; 24(10)2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38793945

RESUMO

The progress in markerless technologies is providing clinicians with tools to shorten the time of assessment rapidly, but raises questions about the potential trade-off in accuracy compared to traditional marker-based systems. This study evaluated the OpenCap system against a traditional marker-based system-Vicon. Our focus was on its performance in capturing walking both toward and away from two iPhone cameras in the same setting, which allowed capturing the Timed Up and Go (TUG) test. The performance of the OpenCap system was compared to that of a standard marker-based system by comparing spatial-temporal and kinematic parameters in 10 participants. The study focused on identifying potential discrepancies in accuracy and comparing results using correlation analysis. Case examples further explored our results. The OpenCap system demonstrated good accuracy in spatial-temporal parameters but faced challenges in accurately capturing kinematic parameters, especially in the walking direction facing away from the cameras. Notably, the two walking directions observed significant differences in pelvic obliquity, hip abduction, and ankle flexion. Our findings suggest areas for improvement in markerless technologies, highlighting their potential in clinical settings.


Assuntos
Análise da Marcha , Marcha , Smartphone , Caminhada , Humanos , Projetos Piloto , Análise da Marcha/métodos , Análise da Marcha/instrumentação , Masculino , Fenômenos Biomecânicos/fisiologia , Feminino , Marcha/fisiologia , Caminhada/fisiologia , Adulto
3.
Trop Anim Health Prod ; 56(7): 242, 2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39172345

RESUMO

Recycled manure solids has emerged as a promising alternative for animal bedding, owing to its economic feasibility, ready availability on farms, and soft, non-abrasive nature. This research aimed to assess the impact of recycled manure solids (RMS) bedding, combined with a conditioner containing 7.5% lime and 6% sodium hydrosulphate, on dairy cow welfare and gait kinematics over three months. Hock and knee injury scores, lameness incidence, and gait kinematic parameters were evaluated for animals housed on cement flooring (Control), RMS bedding (Treatment I), and conditioner-added RMS bedding (Treatment II) on days 0, 45, and 90 of the experiment with six crossbred cows in each group. The results revealed a significant reduction (p < 0.05) in lameness scores (5-point scale) for animals in both the RMS and conditioner-added RMS groups, with scores of 1.09 ± 0.05 and 1.04 ± 0.03, respectively, compared to those on cement floors. Moreover, a noteworthy decrease (p < 0.05) in knee and hock injury scores (4-point scale) was observed in the RMS groups, indicating a potentially positive impact on joint health. Gait kinematic analysis demonstrated that animals in the RMS (1.03 ± 0.04 m/s) and conditioner-added RMS (1.02 ± 0.06 m/s) groups exhibited higher walking speeds and increased step angles (158.59 ± 4.82° and 149.58 ± 3.85°) compared to their cement-floor counterparts. No significant changes (p > 0.05) were observed in stride length, step asymmetry, step length, and step width. The study concluded that the conditioner incorporated recycled manure solids resulting in a substantial decrease in lameness incidence and a reduction in hock and knee injuries among dairy cows. Additionally, the improved gait kinematics observed in non-lame animals suggest that this bedding combination positively influences overall animal well-being. These findings underscore the potential of sustainable bedding practices to enhance both physical health and locomotor behaviour in dairy cattle.


Assuntos
Doenças dos Bovinos , Indústria de Laticínios , Marcha , Abrigo para Animais , Coxeadura Animal , Locomoção , Esterco , Animais , Bovinos , Coxeadura Animal/epidemiologia , Coxeadura Animal/prevenção & controle , Feminino , Fenômenos Biomecânicos , Doenças dos Bovinos/prevenção & controle , Doenças dos Bovinos/epidemiologia , Indústria de Laticínios/métodos , Esterco/análise , Casco e Garras , Incidência , Bem-Estar do Animal , Reciclagem , Pisos e Cobertura de Pisos
4.
Sensors (Basel) ; 23(14)2023 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-37514552

RESUMO

This study aimed to assess whether the Teslasuit, a wearable motion-sensing technology, could detect subtle changes in gait following slip perturbations comparable to an infrared motion capture system. A total of 12 participants wore Teslasuits equipped with inertial measurement units (IMUs) and reflective markers. The experiments were conducted using the Motek GRAIL system, which allowed for accurate timing of slip perturbations during heel strikes. The data from Teslasuit and camera systems were analyzed using statistical parameter mapping (SPM) to compare gait patterns from the two systems and before and after slip. We found significant changes in ankle angles and moments before and after slip perturbations. We also found that step width significantly increased after slip perturbations (p = 0.03) and total double support time significantly decreased after slip (p = 0.01). However, we found that initial double support time significantly increased after slip (p = 0.01). However, there were no significant differences observed between the Teslasuit and motion capture systems in terms of kinematic curves for ankle, knee, and hip movements. The Teslasuit showed promise as an alternative to camera-based motion capture systems for assessing ankle, knee, and hip kinematics during slips. However, some limitations were noted, including kinematics magnitude differences between the two systems. The findings of this study contribute to the understanding of gait adaptations due to sequential slips and potential use of Teslasuit for fall prevention strategies, such as perturbation training.


Assuntos
Marcha , Caminhada , Humanos , Adulto Jovem , Fenômenos Biomecânicos , Extremidade Inferior , Articulação do Tornozelo
5.
Sensors (Basel) ; 23(15)2023 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-37571727

RESUMO

Three-dimensional (3D) cameras used for gait assessment obviate the need for bodily markers or sensors, making them particularly interesting for clinical applications. Due to their limited field of view, their application has predominantly focused on evaluating gait patterns within short walking distances. However, assessment of gait consistency requires testing over a longer walking distance. The aim of this study is to validate the accuracy for gait assessment of a previously developed method that determines walking spatiotemporal parameters and kinematics measured with a 3D camera mounted on a mobile robot base (ROBOGait). Walking parameters measured with this system were compared with measurements with Xsens IMUs. The experiments were performed on a non-linear corridor of approximately 50 m, resembling the environment of a conventional rehabilitation facility. Eleven individuals exhibiting normal motor function were recruited to walk and to simulate gait patterns representative of common neurological conditions: Cerebral Palsy, Multiple Sclerosis, and Cerebellar Ataxia. Generalized estimating equations were used to determine statistical differences between the measurement systems and between walking conditions. When comparing walking parameters between paired measures of the systems, significant differences were found for eight out of 18 descriptors: range of motion (ROM) of trunk and pelvis tilt, maximum knee flexion in loading response, knee position at toe-off, stride length, step time, cadence; and stance duration. When analyzing how ROBOGait can distinguish simulated pathological gait from physiological gait, a mean accuracy of 70.4%, a sensitivity of 49.3%, and a specificity of 74.4% were found when compared with the Xsens system. The most important gait abnormalities related to the clinical conditions were successfully detected by ROBOGait. The descriptors that best distinguished simulated pathological walking from normal walking in both systems were step width and stride length. This study underscores the promising potential of 3D cameras and encourages exploring their use in clinical gait analysis.


Assuntos
Marcha , Caminhada , Humanos , Marcha/fisiologia , Caminhada/fisiologia , Extremidade Inferior , Joelho , Articulação do Joelho , Fenômenos Biomecânicos
6.
Sensors (Basel) ; 24(1)2023 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-38203110

RESUMO

Lower limb exoskeletons and orthoses have been increasingly used to assist the user during gait rehabilitation through torque transmission and motor stability. However, the physical human-robot interface (HRi) has not been properly addressed. Current orthoses lead to spurious forces at the HRi that cause adverse effects and high abandonment rates. This study aims to assess and compare, in a holistic approach, human-robot joint misalignment and gait kinematics in three fixation designs of ankle-foot orthoses (AFOs). These are AFOs with a frontal shin guard (F-AFO), lateral shin guard (L-AFO), and the ankle modulus of the H2 exoskeleton (H2-AFO). An experimental protocol was implemented to assess misalignment, fixation displacement, pressure interactions, user-perceived comfort, and gait kinematics during walking with the three AFOs. The F-AFO showed reduced vertical misalignment (peak of 1.37 ± 0.90 cm, p-value < 0.05), interactions (median pressures of 0.39-3.12 kPa), and higher user-perceived comfort (p-value < 0.05) when compared to H2-AFO (peak misalignment of 2.95 ± 0.64 and pressures ranging from 3.19 to 19.78 kPa). F-AFO also improves the L-AFO in pressure (median pressures ranging from 8.64 to 10.83 kPa) and comfort (p-value < 0.05). All AFOs significantly modified hip joint angle regarding control gait (p-value < 0.01), while the H2-AFO also affected knee joint angle (p-value < 0.01) and gait spatiotemporal parameters (p-value < 0.05). Overall, findings indicate that an AFO with a frontal shin guard and a sports shoe is effective at reducing misalignment and pressure at the HRI, increasing comfort with slight changes in gait kinematics.


Assuntos
Órtoses do Pé , Robótica , Humanos , Fenômenos Biomecânicos , Tornozelo , Marcha
7.
J Sport Rehabil ; 32(8): 903-909, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37758257

RESUMO

CONTEXT: Single- and dual-task walking gait assessments have been used to identify persistent movement and cognitive dysfunction among athletes with concussions. However, it is unclear whether previous ankle sprain injuries confound these outcomes during baseline testing. The purpose of this study was to determine the effects of (1) ankle sprain history and (2) time since prior ankle sprain injury on single- and dual-task spatiotemporal gait outcomes and cognitive measures. DESIGN: Cross-sectional study. METHODS: We assessed 60 college Division-I athletes (31 with ankle sprain history; 13 females and 18 males, 19.3 [0.8] y; 29 with no ankle sprain history, 14 females and 15 males, 19.7 [0.9] y) who completed injury history forms and underwent concussion baseline testing. Athletes completed single- and dual-task gait assessments by walking back and forth along an 8-m walkway for 40 seconds. Athletes wore a smartphone with an associated mobile application on their lumbar spine to record spatiotemporal gait parameters and dual-task cognitive performance. Separate multivariate analyses of variance were used to assess the effects of ankle sprain injury history on spatiotemporal measures, gait variability, and cognitive performance. We performed a multivariate regression subanalysis on athletes who reported time since injury (n = 23) to assess temporal effects on gait and cognitive performance. RESULTS: Athletes with and without a history of ankle sprains had comparable spatiotemporal and gait variability outcomes during single- (P = .42; P = .13) and dual-task (P = .75; P = .55) conditions. Additionally, ankle sprain injury history did not significantly influence cognitive performance (P = .35). Finally, time since ankle sprain did not significantly affect single- (P = .75) and dual-task gait (P = .69), nor cognitive performance (P = .19). CONCLUSIONS: Ankle sprain injury history did not significantly alter spatiotemporal gait outcomes nor cognitive performance during this common clinical assessment. Future studies may consider including athletes with ankle sprain injury history during concussion assessments.


Assuntos
Traumatismos do Tornozelo , Traumatismos em Atletas , Concussão Encefálica , Entorses e Distensões , Masculino , Feminino , Humanos , Estudos Transversais , Marcha
8.
Eur J Appl Physiol ; 122(5): 1231-1237, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35235031

RESUMO

PURPOSE: We have previously observed substantially higher oxygen uptake in soldiers walking on terrain at night than when performing the same walk in bright daylight. The aims of the present study were to investigate the influence of vision on mechanical efficiency during slow, horizontal, constant-speed walking, and to determine whether any vision influence is modified by load carriage. METHODS: Each subject (n = 15) walked (3.3 km/h) for 10 min on a treadmill in four different conditions: (1) full vision, no carried load, (2) no vision, no carried load, (3) full vision with a 25.5-kg rucksack, (4) no vision with a 25.5-kg rucksack. RESULTS: Oxygen uptake was 0.94 ± 0.12 l/min in condition (1), 1.15 ± 0.20 l/min in (2), 1.15 ± 0.12 l/min in (3) and 1.35 ± 0.19 l/min in (4). Thus, lack of vision increased oxygen uptake by about 19%. Analyses of movement pattern, by use of optical markers attached to the limbs and torso, revealed considerably shorter step length (12 and 10%) in the no vision (2 and 4) than full vision conditions (1 and 3). No vision conditions (2 and 4) increased step width by 6 and 6%, and increased vertical foot clearance by 20 and 16% compared to full vision conditions (1 and 3). CONCLUSION: The results suggest that vision has a marked influence on mechanical efficiency even during entrained, repetitive movements performed on an obstacle-free horizontal surface under highly predictable conditions.


Assuntos
Metabolismo Energético , Caminhada , Fenômenos Biomecânicos , Teste de Esforço , Marcha , Humanos , Oxigênio
9.
Sensors (Basel) ; 22(15)2022 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-35957218

RESUMO

The use of inertial measurement units (IMUs) to compute gait outputs, such as the 3D lower-limb kinematics is of huge potential, but no consensus on the procedures and algorithms exists. This study aimed at evaluating the validity of a 7-IMUs system against the optoelectronic system. Ten asymptomatic subjects were included. They wore IMUs on their feet, shanks, thighs and pelvis. The IMUs were embedded in clusters with reflective markers. Reference kinematics was computed from anatomical markers. Gait kinematics was obtained from accelerometer and gyroscope data after sensor orientation estimation and sensor-to-segment (S2S) calibration steps. The S2S calibration steps were also applied to the cluster data. IMU-based and cluster-based kinematics were compared to the reference through root mean square errors (RMSEs), centered RMSEs (after mean removal), correlation coefficients (CCs) and differences in amplitude. The mean RMSE and centered RMSE were, respectively, 7.5° and 4.0° for IMU-kinematics, and 7.9° and 3.8° for cluster-kinematics. Very good CCs were found in the sagittal plane for both IMUs and cluster-based kinematics at the hip, knee and ankle levels (CCs > 0.85). The overall mean amplitude difference was about 7°. These results reflected good accordance in our system with the reference, especially in the sagittal plane, but the presence of offsets requires caution for clinical use.


Assuntos
Marcha , Extremidade Inferior , Acelerometria , Fenômenos Biomecânicos , Calibragem , Humanos
10.
Eur J Neurosci ; 53(4): 1324-1333, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32979289

RESUMO

People with cognitive impairments show deficits during physical performances such as gait, in particular during cognitively challenging conditions (i.e. dual-task gait [DTG]). However, it is unclear if people at risk of dementia, such as those with subjective memory complaints (SMC), also display gait and central deficits associated with DTG. In this study, we investigated the effects of single- and dual-task gait (STG and DTG), on left prefrontal cortex (PFC) activation in elderly people with subjective memory complaints (SMC) and Dementia. A total of 58 older adults (aged 65-94 years; 26 Healthy; 23 SMC; 9 Dementia) were recruited. Gait spatiotemporal characteristics (i.e. stride velocity and length) were assessed using an instrumented walkway during STG and DTG. Single-channel functional near-infrared spectroscopy over the left PFC was used to measure changes in oxyhaemoglobin (O2 Hb) during gait. Stride velocity and length during STG (all p < .05) and DTG (all p < .000) were significantly impaired in people with Dementia compared to Healthy and SMC individuals. No differences were observed between Healthy and SMC. For STG, a greater increase in O2 Hb (p < .05) was observed in those with Dementia compared to the Healthy and SMC, while no differences were observed between Healthy and SMC. A significant increase and decline in O2 Hb was observed during DTG in the SMC and Dementia groups, respectively, compared to Healthy. Our findings indicate an altered pattern of cerebral haemodynamic response of the left PFC in DTG in people with SMC and Dementia, which may suggest that central changes precede functional impairments in people with SMC.


Assuntos
Disfunção Cognitiva , Demência , Idoso , Marcha , Humanos , Memória , Córtex Pré-Frontal
11.
J Appl Biomech ; 37(6): 522-530, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34689127

RESUMO

Individuals with lower limb loss often walk with altered/asymmetric movement mechanics, postulated as a catalyst for development of low back and knee pain. Here, the authors simultaneously investigated trunk-pelvic movement patterns and lower limb joint kinematics and kinetics among 38 males with traumatic, unilateral lower limb loss (23 transtibial and 15 transfemoral), and 15 males without limb loss, at a self-selected and 2 standardized (1.0 and 1.6 m/s) speeds. Individuals with versus without lower limb loss walked with greater trunk range of motion in the frontal and transverse planes at all speeds (despite ∼10% slower self-selected speeds). At all speeds, individuals with versus without limb loss exhibited +29% larger medial ground reaction forces, and at 1.6 m/s also exhibited +50% to 110% larger vertical hip power generation, +27% to 80% larger vertical hip power absorption, and +21% to 90% larger medial-lateral hip power absorption. Moreover, pervasive biomechanical differences between transtibial versus transfemoral limb loss identify amputation-level movement strategies. Overall, greater demands on the musculoskeletal system across walking speeds, particularly at the hip, knee, and low back, highlight potential risk factors for the development/recurrence of prevalent secondary musculoskeletal conditions (eg, joint degeneration and pain) following limb loss.


Assuntos
Amputados , Velocidade de Caminhada , Fenômenos Biomecânicos , Marcha , Humanos , Articulação do Joelho , Extremidade Inferior , Masculino , Caminhada
12.
BMC Musculoskelet Disord ; 21(1): 434, 2020 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-32622357

RESUMO

BACKGROUND: Design modifications in prostheses may cause alterations in gait kinematics, thus influencing functional restoration of knees after total knee arthroplasty (TKA). The aim of the study was to investigate the differences in gait kinematics and clinical outcomes after single radius (SR) versus multiple radius (MR) TKA. METHOD: The present retrospective study included 38 unilateral TKA involving 20 knees using MR design implant and 18 knees using SR design implant. Thirty-six healthy volunteers were also recruited. The mean follow-up time was 16 ± 3 months. At the end of follow-up, the 6 degrees of freedom (DOF) kinematics of knees and range of motion (ROM) were measured with a portable optical tracking system. Knee society score (KSS) and knee injury, and osteoarthritis outcome score (KOOS) were also collected. RESULTS: Patients in the SR group had significantly higher scores in activities of daily living (84.7 ± 15.9) and sports and recreation (67.5 ± 25.2) KOOS sub-score than MR group (69.9 ± 17.6, P = 0.012; 50.0 ± 20.8, P = 0.027, respectively). Significant differences were detected between MR knees and SR knees (1.82° ± 3.11° vs 4.93° ± 3.58°, P = 0.009), and MR knees and healthy knees (1.82° ± 3.11° vs 3.62° ± 3.52°, P = 0.032) in adduction/abduction ROM. The proximal/distal translation was significantly smaller in MR knees (0.58 ± 0.54 cm) compared with SR knees (1.03 ± 0.53 cm, P = 0.003) or healthy knees (0.84 ± 0.45 cm, P = 0.039). SR knees (0.24 ± 0.40 cm) had smaller translation compared with the MR group (0.54 ± 0.33 cm, P = 0.017) and control group (0.67 ± 0.36 cm, P = 0.028). No significant difference was detected in the other DOFs during the gait cycle. Significant difference was detected in extension/flexion, internal/external rotation, adduction/abduction, proximal/distal and medial/lateral among MR, SR and healthy knees. CONCLUSION: After TKA, patients have altered gait kinematics compared with the control group. MR and SR design showed varied characteristics in 6 DOF gait kinematics, which could be the cause of the difference in functional outcome.


Assuntos
Artroplastia do Joelho/métodos , Marcha , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular , Atividades Cotidianas , Idoso , Fenômenos Biomecânicos , Feminino , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tíbia/cirurgia , Caminhada
13.
Sensors (Basel) ; 20(18)2020 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-32932627

RESUMO

Manual carrying of heavy weight poses a major risk for work-related low back injury. Body-worn inertial sensors present opportunities to study the effects of ambulatory work tasks such as load carriage in more realistic conditions. An immediate effect of load carriage is reflected in altered gait kinematics. To determine the effects of load carriage mode and magnitude on gait parameters using body-worn angular rate gyroscopes, two laboratory experiments (n = 9 and n = 10, respectively) were conducted. Participants performed walk trials at self-selected speeds while carrying hand loads in two modes (two-handed side vs. anterior) at four load levels (empty-handed, 4.5 kg, 9.1 kg, and 13.6 kg). Six measures of postural sway and three measures of thoracic-pelvic coordination were calculated from data recorded by four body-worn gyroscopes for 1517 gait cycles. Results demonstrated that, after adjusting for relative walking speed, thoracic-pelvic sway, and movement coordination particularly in the coronal and transverse planes, characterized by gyroscope-based kinematic gait parameters, are systematically altered by the mode of load carriage and load magnitude. Similar trends were obtained for an anthropometrically homogenous (Expt-1) and diverse (Expt-2) sample after adjusting for individual differences in relative walking speed. Measures of thoracic-pelvic coordination and sway showed trends of significant practical relevance and may provide sufficient information to typify alterations in gait across two-handed side vs. anterior load carriage of different load magnitudes. This study contributes to understanding the effects of manual load carriage on thoracic-pelvic movement and the potential application of body-worn gyroscopes to measuring these gait adaptations in naturalistic work settings.


Assuntos
Monitorização Fisiológica , Pelve , Caminhada , Dispositivos Eletrônicos Vestíveis , Fenômenos Biomecânicos , Marcha , Humanos , Suporte de Carga
14.
Sensors (Basel) ; 20(16)2020 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-32824159

RESUMO

The use of machine learning to estimate joint angles from inertial sensors is a promising approach to in-field motion analysis. In this context, the simplification of the measurements by using a small number of sensors is of great interest. Neural networks have the opportunity to estimate joint angles from a sparse dataset, which enables the reduction of sensors necessary for the determination of all three-dimensional lower limb joint angles. Additionally, the dimensions of the problem can be simplified using principal component analysis. Training a long short-term memory neural network on the prediction of 3D lower limb joint angles based on inertial data showed that three sensors placed on the pelvis and both shanks are sufficient. The application of principal component analysis to the data of five sensors did not reveal improved results. The use of longer motion sequences compared to time-normalised gait cycles seems to be advantageous for the prediction accuracy, which bridges the gap to real-time applications of long short-term memory neural networks in the future.

15.
Adv Exp Med Biol ; 1096: 1-9, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29594754

RESUMO

The aim of the study was to assess the influence of a physiotherapy program based on proprioceptive neuromuscular facilitation (PNF) on kinematic gait pattern after total knee arthroplasty. This comparative study included two groups of patients qualified for total surgical knee joint replacement due to osteoarthritis: a study group and a control group, either consisting of 28 patients of a matched age range of 55-90 years. Following surgery, 4 days after standard postoperative rehabilitation, the study patients were subjected to a 3-week-long therapist-assisted rehabilitation based on PNF principles (10 sessions of 75 min each), whereas control patients were discharged with instructions on how to exercise in the home setting. The outcome consisted of spatial-temporal gait parameters that were assessed at three time points: a day before surgery and then 1 month and 6 months after. The findings were that PNF caused substantial, sustained improvements in gait kinematics, shortening the stance phases, gait cycle duration, and double support phase and prolonging swing phase velocity, gait velocity, cadence, step length, and gait cycle length. Also, postsurgical pain was evidently less. We conclude that the individually tailored PNF rehabilitation program is superior compared to a standard recommendation of home-based physiotherapy in terms of improving gait kinematic pattern as well as psychological aspects related to pain perception in patients after knee arthroplasty.


Assuntos
Artroplastia do Joelho/reabilitação , Marcha/fisiologia , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/reabilitação , Modalidades de Fisioterapia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/fisiopatologia , Período Pós-Operatório , Amplitude de Movimento Articular , Resultado do Tratamento
16.
Neurobiol Learn Mem ; 128: 1-6, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26589520

RESUMO

The healthy aging process affects the ability to learn and remember new facts and tasks. Prior work has shown that motor learning can be adversely affected by non-motor deficits, such as time. Here we investigated how age, and a dual task influence the learning and forgetting of a new walking pattern. We studied healthy younger (<30 yo) and older adults (>50 yo) as they alternated between 5-min bouts of split-belt treadmill walking and resting. Older subjects learned a new walking pattern at the same rate as younger subjects, but forgot some of the new pattern during the rest breaks. We tested if forgetting was due to reliance on a cognitive strategy that was not fully engaged after rest breaks. When older subjects performed a dual cognitive task to reduce strategic control of split-belt walking, their adaptation rate slowed, but they still forgot much of the new pattern during the rest breaks. Our results demonstrate that the healthy aging process is one component that weakens motor memories during rest breaks and that this phenomenon cannot be explained solely by reliance on a conscious strategy in older adults.


Assuntos
Adaptação Fisiológica , Envelhecimento , Rememoração Mental/fisiologia , Caminhada , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
17.
Ergonomics ; 59(5): 717-28, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26555738

RESUMO

Protective footwear is necessary for preventing injurious slips and falls in winter conditions. Valid methods for assessing footwear slip resistance on winter surfaces are needed in order to evaluate footwear and outsole designs. The purpose of this study was to utilise a method of testing winter footwear that was ecologically valid in terms of involving actual human testers walking on realistic winter surfaces to produce objective measures of slip resistance. During the experiment, eight participants tested six styles of footwear on wet ice, on dry ice, and on dry ice after walking over soft snow. Slip resistance was measured by determining the maximum incline angles participants were able to walk up and down in each footwear-surface combination. The results indicated that testing on a variety of surfaces is necessary for establishing winter footwear performance and that standard mechanical bench tests for footwear slip resistance do not adequately reflect actual performance. Practitioner Summary: Existing standardised methods for measuring footwear slip resistance lack validation on winter surfaces. By determining the maximum inclines participants could walk up and down slopes of wet ice, dry ice, and ice with snow, in a range of footwear, an ecologically valid test for measuring winter footwear performance was established.


Assuntos
Acidentes por Quedas/prevenção & controle , Marcha , Gelo , Roupa de Proteção , Sapatos , Neve , Adulto , Fenômenos Biomecânicos , Desenho de Equipamento , Fricção , Humanos , Masculino , Propriedades de Superfície , Adulto Jovem
18.
Somatosens Mot Res ; 32(1): 31-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25162146

RESUMO

It has been proposed that proprioceptive input is essential to the development of a locomotor body schema that is used to guide the assembly of successful walking. Proprioceptive information is used to signal the need for, and promotion of, locomotor adaptation in response to environmental or internal modifications. The purpose of this investigation was to determine if tendon vibration applied to either the hamstrings or quadriceps of participants experiencing split-belt treadmill walking modified lower limb kinematics during the early adaptation period. Modifications in the adaptive process in response to vibration would suggest that the sensory-motor system had been unsuccessful in down weighting the disruptive proprioceptive input resulting from vibration. Ten participants experienced split-belt walking, with and without vibration, while gait kinematics were obtained with a 12-camera collection system. Bilateral hip, knee, and ankle joint angles were calculated and the first five strides after the split were averaged for each subject to create joint angle waveforms for each of the assessed joints, for each experimental condition. The intralimb variables of stride length, percent stance time, and relative timing between various combinations of peak joint angles were assessed using repeated measures MANOVA. Results indicate that vibration had very little impact on the split-belt walking adaptive process, although quadriceps vibration did significantly reduce percent stance time by 1.78% relative to the no vibration condition. The data suggest that the perceptual-motor system was able to down weight the disrupted proprioceptive input such that the locomotor body schema was able to effectively manage the lower limb patterns of motion necessary to adapt to the changing belt speed. Complementary explanations for the current findings are also discussed.


Assuntos
Adaptação Fisiológica/fisiologia , Extremidade Inferior/inervação , Propriocepção/fisiologia , Tendões/inervação , Vibração , Caminhada/fisiologia , Adulto , Fenômenos Biomecânicos , Teste de Esforço , Feminino , Humanos , Masculino , Músculo Esquelético/inervação , Adulto Jovem
19.
IEEE J Transl Eng Health Med ; 12: 182-193, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38088995

RESUMO

Lower-limb gait training (GT) exoskeletons have been successfully used in rehabilitation programs to overcome the burden of locomotor impairment. However, providing suitable net interaction torques to assist patient movements is still a challenge. Previous transparent operation approaches have been tested in treadmill-based GT exoskeletons to improve user-robot interaction. However, it is not yet clear how a transparent lower-limb GT system affects user's gait kinematics during overground walking, which unlike treadmill-based systems, requires active participation of the subjects to maintain stability. In this study, we implemented a transparent operation strategy on the ExoRoboWalker, an overground GT exoskeleton, to investigate its effect on the user's gait. The approach employs a feedback zero-torque controller with feedforward compensation for the exoskeleton's dynamics and actuators' impedance. We analyzed the data of five healthy subjects walking overground with the exoskeleton in transparent mode (ExoTransp) and non-transparent mode (ExoOff) and walking without exoskeleton (NoExo). The transparent controller reduced the user-robot interaction torque and improved the user's gait kinematics relative to ExoOff. No significant difference in stride length is observed between ExoTransp and NoExo (p = 0.129). However, the subjects showed a significant difference in cadence between ExoTransp (50.9± 1.1 steps/min) and NoExo (93.7 ± 8.7 steps/min) (p = 0.015), but not between ExoTransp and ExoOff (p = 0.644). Results suggest that subjects wearing the exoskeleton adjust their gait as in an attention-demanding task changing the spatiotemporal gait characteristics likely to improve gait balance.


Assuntos
Exoesqueleto Energizado , Humanos , Marcha , Caminhada , Movimento , Modalidades de Fisioterapia
20.
J Orthop ; 57: 83-89, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39006209

RESUMO

Background: Understanding joint loading and the crucial role of joint moments is essential for developing treatment strategies in gait analysis, which often requires the precise estimation of joint moments through an inverse dynamic approach. This process necessitates the use of a force plate synchronized with a motion capture system. However, effectively capturing ground reaction force in typically developing (TD) children and those with congenital talipes equino varus (CTEV) presents challenges, while the availability and high cost of additional force plates pose additional challenges. Therefore the study aimed to develop, train, and identify the most effective machine learning (ML) model to predict joint moments from kinematics for TD children and those with CTEV. Method: In a study at the Gait Lab, 13 children with bilateral CTEV and 17 TD children underwent gait analysis to measure kinematics and kinetics, using a 12-camera Qualisys Motion Capture System and an AMTI force plate. ML models were then trained to predict joint moments from kinematic data as input. Results: The random forest regressor and deep neural networks (DNN) proved most effective in predicting joint moments from kinematics for TD children, yielding better results. The Random Forest regressor achieved an average r of 0.75 and nRMSE of 23.03 % for TD children, and r of 0.74 and 23.82 % for CTEV. DNN achieved an average r of 0.75 and nRMSE of 22.83 % for TD children, and r of 0.76 and nRMSE of 23.9 % for CTEV. Conclusions: The findings suggest that using machine learning to predict joint moments from kinematics shows moderate potential as an alternative to traditional gait analysis methods for both TD children and those with CTEV. Despite its potential, the current prediction accuracy limitations hinder the immediate clinical application of these techniques for decision-making in a pediatric population.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA