Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 56(8): 1373-1382, 2018 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-29320362

RESUMO

BACKGROUND: Simultaneous determination of the two main actin scavenger proteins in sepsis has not been investigated until now. In our pilot study, we elucidated the predictive values of Gc globulin and gelsolin (GSN) in sepsis by comparing them to classic laboratory and clinical parameters. METHODS: A 5-day follow-up was performed, including 46 septic patients, 28 non-septic patients and 35 outpatients as controls. Serum Gc globulin and GSN levels were determined by automated immune turbidimetric assay on a Cobas 8000/c502 analyzer. Patients were retrospectively categorized according to the sepsis-3 definitions, and 14-day mortality was also investigated. RESULTS: First-day GSN also differentiated sepsis from non-sepsis (AUC: 0.88) similarly to C-reactive protein (AUC: 0.80) but was slightly inferior to procalcitonin (PCT) (AUC: 0.98) with a cutoff value of GSN at 22.29 mg/L (sensitivity: 83.3%; specificity: 86.2%). Only first-day SOFA scores (0.88) and GSN (0.71) distinguished septic survivors from non-survivors, whereas lactate (0.99), Gc globulin (0.76) and mean arterial pressure (MAP) (0.74) discriminated septic shock from sepsis. Logistic regression analyses revealed SOFA scores and GSN being significant factors regarding 14-day mortality. First-day GSN levels were higher (p<0.05) in septic survivors than in non-survivors. Gc globulin levels remained higher (p<0.01) in sepsis when compared with septic shock during the follow-up period. CONCLUSIONS: Both serum GSN and Gc globulin may have predictive values in sepsis. Considering the small sample size of our study, further measurements are needed to evaluate our results. Measurement of Gc globulin and GSN maybe useful in assessment of sepsis severity and in therapeutic decision-making.


Assuntos
Gelsolina/sangue , Sepse/diagnóstico , Proteína de Ligação a Vitamina D/sangue , Idoso , Feminino , Humanos , Imunoturbidimetria , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Prognóstico , Sepse/sangue
2.
J Clin Lab Anal ; 32(3)2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28872708

RESUMO

BACKGROUND: Studies showing the potential predictive value of the actin-binding protein gelsolin, in critically ill patients are scarce. Moreover, even up to now a rapid automated measurement of gelsolin has still remained a challenge. Therefore, we developed and validated an automated serum gelsolin immune turbidimetric assay for possible clinical use. METHODS: Validation of serum gelsolin assay was performed on a Cobas 8000/c502 analyzer (Roche) according to the second edition of Eurachem guidelines. Furthermore, we also studied the diagnostic value of serum gelsolin in sepsis when investigating sera of septic (n = 25), systemic inflammatory response syndrome (SIRS; n = 8) and control patients (n = 14). We compared our previously published Western blot data with those of the new turbidimetric assay. RESULTS: The sample volume was 7 µL and the assay time was 10 minutes. The detection limit was 0.72 mg/L, intra- and inter-assay imprecision remained in most cases less than 5% expressed as CV. Recovery was found to be 84.56%-93.52% and linearity study gave an appropriate correlation coefficient by linear regression analysis (r2  = .998). Septic patients exhibited lower (P = .015) first-day serum gelsolin levels than SIRS patients, which confirmed our previous Western blot results. The determined cut-off point for serum gelsolin was 14.05 mg/L (sensitivity: 75%; specificity: 60%) when investigating its diagnostic value in sepsis. CONCLUSION: Based on the results, our immune turbidimetric measurement offers a rapid and accurate quantitation of gelsolin in human serum samples. Serum gelsolin seems a promising additional diagnostic marker of sepsis which has to be further investigated.


Assuntos
Automação Laboratorial/métodos , Gelsolina/sangue , Nefelometria e Turbidimetria/métodos , Sepse/sangue , Sepse/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Limite de Detecção , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA