1.
J Arthroplasty ; 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38548236

RESUMO

BACKGROUND: Cementless total knee arthroplasty (TKA) has regained interest for its potential for long-term biologic fixation. The density of the bone is related to its ability to resist static and cyclic loading and can affect long-term implant fixation; however, little is known about the density distribution of periarticular bone in TKA patients. Thus, we sought to characterize the bone mineral density (BMD) of the proximal tibia in TKA patients. METHODS: We included 42 women and 50 men (mean age 63 years, range: 50 to 87; mean body mass index 31.6, range: 20.5 to 49.1) who underwent robotic-assisted TKA and had preoperative computed tomography scans with a BMD calibration phantom. Using the robotic surgical plan, we computed the BMD distribution at 1 mm-spaced cross-sections parallel to the tibial cut from 2 mm above the cut to 10 mm below. The BMD was analyzed with respect to patient sex, age, preoperative alignment, and type of fixation. RESULTS: The BMD decreased from proximal to distal. The greatest changes occurred within ± 2 mm of the tibial cut. Age did not affect BMD for men; however, women between 60 and 70 years had higher BMD than women ≥ 70 years for the total cut (P = .03) and the medial half of the cut (P = .03). Cemented implants were used in 1 86-year-old man and 18 women (seven < 60 years, seven 60 to 70 years, and four ≥ 70 year old). We found only BMD differences between cemented or cementless fixation for women < 60 years. CONCLUSIONS: To our knowledge, this is the first study to characterize the preoperative BMD distribution in TKA patients relative to the intraoperative tibial cut. Our results indicate that while sex and age may be useful surrogates of BMD, the clinically relevant thresholds for cementless knees remain unclear, offering an area for future studies.

2.
Artigo em Russo | MEDLINE | ID: mdl-38549407

RESUMO

OBJECTIVE: To evaluate mechanical strength of three methods of polymethyl methacrylate skull implant fixation in two experimental models. MATERIAL AND METHODS: The first experiment was performed on a plastic model that was as close as possible to bone in structural characteristics. The second experiment was performed on a biological specimen (a ram's head). We assessed the quality of implant fixation to bone window edges by craniofixes, ties and microscrews and lateral intercortical screws. RESULTS: Craniofixes are feasible for small flat flaps, but not advisable for wide highly curved implants. They are also the most expensive method of fixation. Implant fixation by ties and microscrews is a universal method comparable in price to craniofix. Lateral intercortical fixation is effective both for small flat implants and wide implants with large curvature. However, this method is not always applicable. CONCLUSION: Combined fixation by lateral intercortical screws and ties allows for the most effective fixation while reducing the overall price of consumables.


Assuntos
Polimetil Metacrilato , Titânio , Masculino , Animais , Ovinos , Polimetil Metacrilato/química , Crânio/cirurgia , Próteses e Implantes , Craniotomia/métodos
3.
J Arthroplasty ; 38(6): 1052-1056, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36858126

RESUMO

BACKGROUND: This study investigated the presence and progression of radiolucent lines (RLLs) after cemented total knee arthroplasty (TKA) with or without tourniquet use. METHODS: There were 369 consecutive primary cemented TKAs with 5 to 8 years of follow-up. A tourniquet was used during component cementation in patients who underwent surgery from January 3, 2006, to March 31, 2010. No tourniquet was used from August 14, 2009, to October 14, 2014. There were 192 patients in the tourniquet group (TQ) and 177 patients in the no tourniquet group (NQ). Patient demographics, reoperations, and complications were recorded. RLLs were identified on anteroposterior, lateral, and skyline x-rays at 1, 2, and 5 to 8 years postoperatively using the modern knee society radiographic evaluation system. Demographics, reoperations, complications, and RLLs were compared. Age, sex, and body mass index were similar between groups. Mean tourniquet time in TQ was 11 minutes (range, 8 to 25). RESULTS: The presence of RLLs differed between groups, with 65% of TQ knees having RLLs under any part of the prostheses versus 46% of NQ knees (P < .001). The progression of RLL >2 mm occurred in 26.0% of knees in TQ and 16.7% of knees in NQ (P = .028). There were 13 TKAs that underwent subsequent revision surgery. There was no statistically or clinically significant difference in revision rate between groups (7 revisions in TQ, 6 in NQ, P = .66). CONCLUSION: Less RLLs were identified in NQ versus TQ. There were no statistically or clinically significant differences in revision rates between the NQ and TQ groups at 5 to 8 years.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Cimentação , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Radiografia , Reoperação , Resultado do Tratamento
4.
J Arthroplasty ; 37(1): 162-167, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34592354

RESUMO

INTRODUCTION: Aseptic tibial loosening is now considered the most common reason that total knee arthroplasties (TKA) fail long term. There are unique subsets of patients that fail into varus alignment of the tibial tray with collapse of the medial proximal tibia. It is currently unknown if the implant fixation fails first or if the proximal medial tibia collapses first. MATERIALS: We performed a retrospective analysis of 88 patients that were revised at our institution secondary to aseptic varus collapse of the proximal tibia. Two fellowship-trained arthroplasty surgeons performed a retrospective analysis on sequential precollapse radiographs in each patient to determine which failed first: the implant fixation (implant-cement or cement-bone interface) or the medial proximal tibia. DISCUSSION: 36/88 (40.9%) patients had a series of precollapse radiographs that could be reviewed. Failure at the implant-cement interface before varus collapse in 23 vs 22 patients, failure at the implant-cement and cement-bone interface before varus collapse in two patients, and contemporaneous failure at the implant-cement interface and varus collapse in 11 vs 12 patients were identified by reviewers one and two, respectively. CONCLUSION: The most frequent mechanism of failure identified was failure of the implant-cement interface followed by subsequent medial tibial varus collapse. Improving implant fixation may decrease the incidence of this unique failure mechanism. We advocate the use of supplemental stem fixation in high-risk patients and optimal cement techniques for all patients as methods of potentially avoiding tibial varus collapse, one of the most frequent modes of long-term failure.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Artroplastia do Joelho/efeitos adversos , Cimentos Ósseos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Falha de Prótese , Estudos Retrospectivos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
5.
J Arthroplasty ; 37(11): 2272-2281, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35588902

RESUMO

BACKGROUND: Early total knee arthroplasty failures continue to surface in the literature. Cementation technique and implant design are two of the most important scenarios that can affect implant survivorship. Our objectives were to develop a more suitable preclinical test to evaluate the endurance of the implant-cement-bone interface under anterior shear and internal-external (I/E) torsional shear testing condition in a biomechanical sawbones. METHODS: Implants tested included the AS VEGA System PS and the AS Columbus CR/PS (Aesculap AG, Germany), with zirconium nitride (ZrN) coating. Tibial implants were evaluated under anterior shear and I/E torsional shear conditions with 6 samples in 4 test groups. For the evaluation of the I/E torsional shear endurance behavior, a test setup was created allowing for clinically relevant I/E rotation with simultaneous high axial/tibio-femoral load. The test was performed with an I/E displacement of ±17.2°, for 1 million cycles with an axial preload of 3,000 N. RESULTS: After the anterior shear test an implant-cement-bone fixation strength for the AS VEGA System tibial tray of 2,674 ± 754 N and for the AS Columbus CR/PS tibial tray of 2,177 ± 429 N was determined (P = .191). After I/E rotational shear testing an implant-cement-bone fixation strength for the AS VEGA System PS tray of 2,561 ± 519 N and for the AS Columbus CR/PS tray of 2,824 ± 515 N was resulted (P = .39). CONCLUSION: Both methods had varying degrees of failure modes from debonding to failure of the sawbones foam. These two intense biomechanical loading tests are more strenuous and more representative of clinical activity.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Cimentos Ósseos , Cimentação/métodos , Fêmur/cirurgia , Humanos , Tíbia/cirurgia
6.
FASEB J ; 34(11): 14302-14317, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32931052

RESUMO

Particles released from implants cause inflammatory bone loss, which is a key factor in aseptic loosening, the most common reason for joint replacement failure. With the anticipated increased incidence of total joint replacement in the next decade, implant failure will continue to burden patients. The gut microbiome is increasingly recognized as an important factor in bone physiology, however, its role in implant loosening is currently unknown. We tested the hypothesis that implant loosening is associated with changes in the gut microbiota in a preclinical model. When the particle challenge caused local joint inflammation, decreased peri-implant bone volume, and decreased implant fixation, the gut microbiota was affected. When the particle challenge did not cause this triad of local effects, the gut microbiota was not affected. Our results suggest that cross-talk between these compartments is a previously unrecognized mechanism of failure following total joint replacement.


Assuntos
Microbioma Gastrointestinal , Inflamação/patologia , Osteólise/patologia , Próteses e Implantes/efeitos adversos , Infecções Relacionadas à Prótese/patologia , Animais , Inflamação/etiologia , Masculino , Osteólise/etiologia , Infecções Relacionadas à Prótese/etiologia , Ratos
7.
Arch Orthop Trauma Surg ; 141(10): 1669-1675, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32757034

RESUMO

INTRODUCTION: Surgically balanced total knee arthroplasties have shown improved functional and clinical outcomes. Two different alignment methods have been proposed, the measured resection technique which uses femoral landmarks on the one hand and the ligament balanced technique which uses spreaders on the other. As anatomical landmarks also vary widely, with regards to the tibial cut irrespective of the collateral ligaments, we hypothesized that anatomical landmarks are not suitable for ideal femoral component rotational alignment. MATERIALS AND METHODS: Ten cadaveric bilateral knees underwent TKA using a navigational device and a double tensiometer. By means of the navigational device, flexion gaps were balanced by femoral component size, rotation and flexion until a symmetric flexion and extension gap was obtained. Acquired femoral component rotation was compared to femoral landmarks (Whiteside Line, posterior condylar line and trans-epicondylar line). RESULTS: Using the Whiteside line, the posterior condylar line and the surgical trans-epicondylar line to identify femoral component rotation did not balance the flexion gap as well as navigation. Depending on the parameter, deviations in femoral rotation of up to 6° were observed compared to the gap balancing technique. Furthermore, large deviations between these landmarks were observed. CONCLUSION: Based on this study flexion gap balancing can be better optimized using ligament balancing technique. As this technique is highly dependent on the proximal tibial cut, we do recommend the use of navigational devices, which additionally assure a neutral leg alignment.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular
8.
Khirurgiia (Mosk) ; (1): 34-41, 2021.
Artigo em Russo | MEDLINE | ID: mdl-33395510

RESUMO

OBJECTIVE: To compare early and long-term results of various mesh prosthesis fixation methods in laparoscopic inguinal hernia repair. MATERIAL AND METHODS: It is a prospective clinical non-randomized trial. The study included 212 patients. Conventional stapler fixation (112 patients), self-gripping mesh implants (48 patients) and n-butyl cyanoacrylate adhesive fixation (52 patients) were compared. We estimated surgery time, pain syndrome severity in early and long-term postoperative period, postoperative morbidity and recurrence rate were evaluated. RESULTS: Early postoperative morbidity, activation of patients and hospital-stay were similar in all groups. Pain syndrome within 6 postoperative hours in the first group exceeded the same parameter in the second group by 1.23 times (95% CI 1.15-1.31, p<0.05) and by 1.19 times in the third group (95% CI 1.12-1.26, p<0.05). Within 12 hours, pain syndrome in the first group was 1.27 times more severe compared to the third group (95% CI 1.20-1.34, p<0.05). Pain syndrome in long-term period was similar in all groups. In the first group, one recurrence was detected (0.9%). CONCLUSION: There were no significant between-group differences. However, we found the correlation of postoperative pain syndrome with mesh implant fixation technique.


Assuntos
Hérnia Inguinal , Herniorrafia , Laparoscopia , Implantação de Prótese , Telas Cirúrgicas , Cianoacrilatos/administração & dosagem , Cianoacrilatos/efeitos adversos , Hérnia Inguinal/cirurgia , Herniorrafia/efeitos adversos , Humanos , Dor Pós-Operatória/etiologia , Estudos Prospectivos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Telas Cirúrgicas/efeitos adversos , Técnicas de Sutura/efeitos adversos , Procedimentos Cirúrgicos sem Sutura/efeitos adversos , Procedimentos Cirúrgicos sem Sutura/métodos , Fatores de Tempo , Adesivos Teciduais/administração & dosagem , Adesivos Teciduais/efeitos adversos , Resultado do Tratamento
9.
Eur Arch Otorhinolaryngol ; 277(6): 1645-1650, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32162058

RESUMO

PURPOSE: Since the beginning of cochlear implant (CI) surgery, several techniques to fixate the electrode array at the cochleostomy and stabilize it have been described; however, most techniques use autologous tissues such as fascia, muscle, fat or fibrin glue. We describe a new surgical technique aimed to stabilize the electrode array of a CI without using autologous tissues or artificial materials. MATERIALS AND METHODS: The surgical technique described consists in creating three stabilizing channels in the temporal bone for the electrode array. The first one in a partially opened aditus, the second one in a partially preserved Koerner's septum (KS) and the last one in the sinodural angle. The procedure was performed in five human temporal bones using a straight array; a radiography was made to confirm the correct placement of the electrode array and afterwards all temporal bones were shaken using a Titramax 1000 platform. The correct placement of the array post-shaking was then confirmed using the microscope and another radiography. RESULTS: No migration of the electrodes outside the cochlea was observed. The CI cable remained in the same position at the aditus and the KS in all the temporal bones. In three cases (60%), the electrode array moved away from the groove carved in the sinodural angle. CONCLUSIONS: The new surgical technique described stabilizes the electrode array using the temporal bone's normal anatomy, preserving the middle ear spaces, facilitating the ulterior explantation and reimplantation if necessary, and may reduce cost and surgery time.


Assuntos
Implante Coclear , Implantes Cocleares , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Remoção de Dispositivo , Eletrodos Implantados , Humanos , Osso Temporal/diagnóstico por imagem , Osso Temporal/cirurgia
10.
J Arthroplasty ; 35(2): 579-587, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31653466

RESUMO

BACKGROUND: The objectives of this study are to (1) evaluate if there is a potential difference in cemented implant fixation strength between tibial components made out of cobalt-chromium (CrCoMo) and of a ceramic zirconium nitride (ZrN) multilayer coating and to (2) test their behavior with 5 different bone cements in a standardized in vitro model for testing of the implant-cement-bone interface conditions. We also analyzed (3) whether initial fixation strength is a function of timing of the cement apposition and component implantation by an early, mid-term, and late usage within the cement-specific processing window. METHODS: An in vitro study using a synthetic polyurethane foam model was performed to investigate the implant fixation strength after cementation of tibial components by a push-out test. A total of 20 groups (n = 5 each) was used: Vega PS CrCoMo tibia and Vega PS ZrN tibia with the bone cements BonOs R, SmartSet HV, Cobalt HV, Palacos R, and Surgical Simplex P, respectively, using mid-term cement apposition. Three different cement apposition times-early, mid-term, and late usage-were tested with a total of 12 groups (n = 5 each) with the bone cements BonOs R and SmartSet HV. RESULTS: There was no significant difference in implant-cement-bone fixation strength between CrCoMo and ZrN multilayer-coated Vega tibial trays tested with 5 different commonly used bone cements. CONCLUSION: Apposition of bone cements and tibial tray implantation in the early to mid of the cement-specific processing window is beneficial in regard to interface fixation in TKA.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Cimentos Ósseos , Cimentação , Humanos , Tíbia/cirurgia
11.
J Shoulder Elbow Surg ; 28(1): e18-e28, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30274689

RESUMO

BACKGROUND: Glenoid loosening, a common complication of shoulder arthroplasty, could relate to implant design and bone quality. However, the role of bone density has not been tested experimentally yet. In this study, tests on cadaveric specimens of varying bone density were performed to evaluate the effects of bone quality on loosening of typical anatomic glenoid implants. METHODS: Cadaveric scapulae scanned with a quantitative computed tomography scanner to determine bone mineral density (BMD) were implanted with either pegged or keeled cemented glenoid components and tested under constant glenohumeral load while a humeral head component was moved cyclically in the inferior and superior directions. Implant superior and inferior edge lifting, defined as displacement from the underlying bone, was measured with linear variable differential transducers until we reached 23,000 test cycles, and statistical testing was performed for differences in edge lifting due to implant design and related to periprosthetic BMD. RESULTS: Edge lifting was statistically significant at all time points, but on average, implant design had no effect. Lifting was highest in specimens in which BMD below the lifting edge was lower, with trends of increased displacement with decreased BMD. CONCLUSIONS: Implant lifting was greater in glenoids of lower bone density for both implant designs. This finding suggests that fixation failure will most likely occur in bone of lower density and that the fixation design itself may play a secondary role.


Assuntos
Artroplastia do Ombro/métodos , Densidade Óssea , Cabeça do Úmero/cirurgia , Articulação do Ombro/cirurgia , Tomografia Computadorizada por Raios X/métodos , Idoso , Cadáver , Feminino , Humanos , Cabeça do Úmero/diagnóstico por imagem , Masculino , Desenho de Prótese
12.
Arch Orthop Trauma Surg ; 139(6): 843-849, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30887123

RESUMO

INTRODUCTION: High loosening rates after distal femoral replacement may be due to implant design not adapted to specific anatomic and biomechanical conditions. MATERIALS AND METHODS: A modular tumor system (MUTARS®, Implantcast GmbH) was implanted with either a curved hexagonal or a straight tapered stems in eight Sawbones® in two consecutively generated bone defect (10 cm and 20 cm proximal to knee joint level). Implant-bone-interface micromotions were measured to analyze main fixation areas and to characterize the fixation pattern. RESULTS: Although areas of highest relative micromotions were measured distally in all groups, areas and lengths of main fixation differed with respect to stem design and bone defect size. Regardless of these changes, overall micromotions could only be reduced with extending bone defects in case of tapered stems. CONCLUSIONS: The tapered design may be favorable in larger defects whereas the hexagonal may be advantageous in defects located more distally.


Assuntos
Interface Osso-Implante/fisiologia , Fêmur , Procedimentos Ortopédicos/instrumentação , Procedimentos de Cirurgia Plástica/instrumentação , Fêmur/fisiologia , Fêmur/cirurgia , Humanos , Desenho de Prótese
13.
J Arthroplasty ; 33(4): 1215-1221.e1, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29248483

RESUMO

BACKGROUND: Impacted bone allograft is used to restore lost bone in total joint arthroplasties. Bone morphogenetic proteins (BMPs) can induce new bone formation to improve allograft incorporation, but they simultaneously invoke a seemingly dose-dependent allograft resorption mediated by osteoclasts. Bisphosphonates effectively inhibit osteoclast activity. Predicting allograft resorption when augmented with bone morphogenetic protein 2 (BMP-2), we intended to investigate whether a balanced bone metabolism was achievable within a range of BMP-2 doses with systemic zoledronate treatment. METHODS: Implants were coated with 1 of 3 BMP-2 doses (15 µg, 60 µg, and 240 µg) or left untreated. Implants were surrounded by a 2.5-mm gap filled with impacted morselized allograft. Each of the 12 dogs included received 1 of each implant (15 µg, 60 µg, 240 µg, and untreated), 2 in each proximal humerus. During the 4-week observation period, zoledronate intravenous (0.1 mg/kg) was administered to all animals 10 days after surgery as anticatabolic treatment. Implant osseointegration was evaluated by histomorphometry and mechanical push-out tests. RESULTS: Untreated implants had the best mechanical fixation and superior retention of allograft as compared to any of the BMP-2 implants. Both mechanical implant fixation and retention of allograft decreased significantly with BMP-2 dose increments. Surprisingly, there was no difference among the treatment groups in the amount of new bone. CONCLUSION: The use of BMP-2 to augment impaction-grafted implants cannot be recommended even when combined with systemic zoledronate.


Assuntos
Proteína Morfogenética Óssea 2 , Transplante Ósseo , Osteogênese , Próteses e Implantes , Desenho de Prótese , Fator de Crescimento Transformador beta , Ácido Zoledrônico , Animais , Cães , Humanos , Aloenxertos , Osso e Ossos/efeitos dos fármacos , Proteína Morfogenética Óssea 2/administração & dosagem , Difosfonatos/administração & dosagem , Osseointegração/efeitos dos fármacos , Osteogênese/efeitos dos fármacos , Distribuição Aleatória , Proteínas Recombinantes/administração & dosagem , Titânio , Fator de Crescimento Transformador beta/administração & dosagem , Transplante Homólogo , Ácido Zoledrônico/administração & dosagem
14.
Eur J Orthop Surg Traumatol ; 28(4): 621-625, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29299764

RESUMO

PURPOSE: The purpose of this study is to clarify morphological changes of acetabular subchondral bone cyst after total hip arthroplasty for osteoarthritis secondary to developmental dysplasia of the hip. METHODS: Two hundred and sixty-one primary cementless total hip arthroplasties of 208 patients, 18 males, 190 females, were retrospectively reviewed. Morphological changes of subchondral bone cyst were evaluated by computed tomography (CT). The mean cross-sectional area of the cyst from CT scans at 3 months postoperatively and after 7-10 years (average 8.4 years) were compared. RESULTS: Acetabular subchondral bone cysts were found in 49.0% of all cases in preoperative CT scans. There was no cyst which was newly recognized in CT scan performed after postoperative 7-10 years. All the cross-sectional areas of the cysts evaluated in this study were reduced postoperatively. CONCLUSIONS: This study revealed that acetabular subchondral bone cysts do not increase or expand after total hip arthroplasty and indicated that the longitudinal morphological change of acetabular bone cysts in patients of developmental dysplasia of the hip do not influence long-term implant fixation in total hip arthroplasty.


Assuntos
Acetábulo/patologia , Artroplastia de Quadril/métodos , Cistos Ósseos/patologia , Luxação Congênita de Quadril/complicações , Osteoartrite do Quadril/cirurgia , Acetábulo/diagnóstico por imagem , Cistos Ósseos/diagnóstico por imagem , Feminino , Luxação Congênita de Quadril/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/etiologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
15.
J Bone Miner Metab ; 35(5): 497-503, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27714461

RESUMO

Osteoporotic patients have a high risk of dental and orthopedic implant failure. Lithium chloride (LiCl) has been reported to enhance bone formation. However, the role of LiCl in the success rate of dental and orthopedic implants in osteoporotic conditions is still unknown. We investigated whether LiCl enhances implant osseointegration, implant fixation, and bone formation in osteoporotic conditions. Sprague-Dawley female rats (n = 18) were ovariectomized (OVX) to induce osteoporosis, and another nine rats underwent sham surgery. Three months after surgery, titanium implants were implanted in the tibia of the OVX and sham group rats. After implantation, the OVX rats were gavaged with 150 mg/kg/2 days of LiCl (OVX + LiCl group) or saline (OVX group), and sham group rats were gavaged with saline for 3 months. Implant osseointegration and bone formation were analyzed using histology, biomechanical testing, and micro computed tomography (micro-CT). More bone loss was observed in the OVX group compared to the control, and LiCl treatment enhanced bone formation and implant fixation in osteoporotic rats. In the OVX group, bone-implant contact (BIC) was decreased by 81.2 % compared to the sham group. Interestingly, the OVX + LiCl group showed 4.4-fold higher BIC compared to the OVX group. Micro-CT data of tibia from the OVX + LiCl group showed higher bone volume, trabecular thickness, trabecular number, and osseointegration compared to the OVX group. Maximum push-out force and implant-bone interface shear strength were 2.9-fold stronger in the OVX + LiCl group compared to the OVX group. In conclusion, LiCl enhanced implant osseointegration, implant fixation, and bone formation in osteoporotic conditions, suggesting LiCl as a promising therapeutic agent to prevent implant failure and bone loss in osteoporotic conditions.

16.
J Shoulder Elbow Surg ; 26(9): 1653-1661, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28495573

RESUMO

BACKGROUND: Short-stem humeral replacements achieve fixation by anchoring to the metaphyseal trabecular bone. Fixing the implant in high-density bone can provide strong fixation and reduce the risk of loosening. However, there is a lack of data mapping the bone density distribution in the proximal humerus. The aim of the study was to investigate the bone density in proximal humerus. METHODS: Eight computed tomography scans of healthy cadaveric humeri were used to map bone density distribution in the humeral head. The proximal humeral head was divided into 12 slices parallel to the humeral anatomic neck. Each slice was then divided into 4 concentric circles. The slices below the anatomic neck, where short-stem implants have their fixation features, were further divided into radial sectors. The average bone density for each of these regions was calculated, and regions of interest were compared using a repeated-measures analysis of variance with significance set at P < .05. RESULTS: Average apparent bone density was found to decrease from proximal to distal regions, with the majority of higher bone density proximal to the anatomic neck of the humerus (P < .05). Below the anatomic neck, bone density increases from central to peripheral regions, where cortical bone eventually occupies the space (P < .05). In distal slices below the anatomic neck, a higher bone density distribution in the medial calcar region was also observed. CONCLUSION: This study indicates that it is advantageous with respect to implant fixation to preserve some bone above the anatomic neck and epiphyseal plate and to use the denser bone at the periphery.


Assuntos
Artroplastia do Ombro , Cabeça do Úmero/diagnóstico por imagem , Desenho de Prótese , Prótese de Ombro , Idoso , Densidade Óssea , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
17.
J Arthroplasty ; 31(3): 721-6, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26639983

RESUMO

BACKGROUND: Highly porous metal acetabular components illustrate a decreased rate of aseptic loosening in short-term follow-up compared with previous registry data. This study compared the effect of component surface roughness at the bone-implant interface and the quality of the bone on initial pressfit stability. The null hypothesis is that a standard porous coated acetabular cup would show no difference in initial stability as compared with a highly porous acetabular cup when subjected to a bending moment. Second, would bone mineral density (BMD) be a significant variable under these test conditions. METHODS: In a cadaveric model, acetabular cup micromotion was measured during a 1-time cantilever bending moment applied to 2 generations of pressfit acetabular components. BMD data were also obtained from the femoral necks available for associated specimen. RESULTS: The mean bending moment at 150 µm was not found to be significantly different for Gription (24.6 ± 14.0 N m) cups vs Porocoat (25 ± 10.2 N m; P > .84). The peak bending moment tolerated by Gription cups (33.9 ± 20.3 N m) was not found to be significantly different from Porocoat (33.5 ± 12.2 N m; P > .92). No correlation between BMD and bending moment at 150 µm of displacement could be identified. CONCLUSION: The coefficient of friction provided by highly porous metal acetabular shells used in this study did not provide better resistance to migration under bending load when compared with a standard porous coated component.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Desenho de Prótese , Acetábulo , Feminino , Fricção , Humanos , Masculino , Metais , Porosidade , Falha de Prótese
18.
Knee Surg Sports Traumatol Arthrosc ; 23(11): 3273-80, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25026930

RESUMO

PURPOSE: The main purpose of the present study was to determine long-term implant fixation of 15 unicompartmental knee arthroplasty (UKAs) with an all-poly tibial component using Roentgen stereophotogrammetric analysis (RSA) at a mean 10-year follow-up. The secondary purpose was to investigate whether the progressive loss of implant's fixation correlates with a reduction in Knee society score (KSS). METHODS: Fifteen non-consecutive patients with primary knee osteoarthritis received a UKA with an all-poly tibial component were assessed using KSS scores pre-operatively and post-operatively and RSA on day 2 after surgery, then at 3, 6, and 12 months and yearly thereafter. The mean last follow-up was 10 years. RESULTS: An increase in maximum total point motion (MTPM) values from 6 months to 1 year post-operatively was found respect to post-operative reference. Implants' displacement values were always <2 mm during the first 6 months, and then, two different trends were noticed in revised and non-revised implants. MTPM increase between 1 and 2 years of follow-up in non-revised UKAs was always <0.2 mm, whereas it was >0.2 mm in revised UKAs. A linear and negative correlation with statistical significance was found between MTPM and both clinical and functional KSS scores (p < 0.001). CONCLUSION: Also in a long-term follow-up evaluation, RSA is an effective tool to predict functional results after an all-poly UKA providing also a relevant predictive value at 1 year follow-up, and this can be very useful for both patients and surgeons. LEVEL OF EVIDENCE: Diagnostic studies, Level III.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Análise Radioestereométrica , Idoso , Feminino , Seguimentos , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
19.
J Shoulder Elbow Surg ; 24(3): 425-32, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25306495

RESUMO

BACKGROUND: Accurate characterization of regional variations in bone density in symmetric and asymmetric (B2) glenoid erosion patterns can assist with surgical planning, reaming, and component implantation. The purpose of this study was to characterize regional bone density and porosity in symmetric and asymmetric (B2) osteoarthritic glenoids. METHODS: Symmetric (n = 25) and asymmetric (B2) (n = 25) erosion patterns were compared by computed tomography-based imaging software. An orthogonal coordinate system separated each glenoid into quadrants. In addition, a linear best-fit line defined the line-of-erosion between the paleoglenoid and neoglenoid in the asymmetric cohort. All glenoids were further divided into volumes at depths of 0 to 2.5 mm and 2.5 to 5 mm. Average bone density was measured in Hounsfield units. Bone voids or cysts were included to quantify regional porosity as the fraction of void volume to total glenoid volume. RESULTS: For the symmetric cohort, there were no significant differences in bone density between quadrants at either depth (P ≥ .089). For the asymmetric cohort, bone density was significantly higher in the posterior quadrants compared with the anterior quadrants (P < .001), especially posteroinferiorly (P ≤ .007) at both depths. In addition, the neoglenoid had significantly higher density and lower void fraction compared with the paleoglenoid (P < .001). There were also significant differences in void fraction between quadrants for both cohorts, at both depths (P ≤ .004). CONCLUSIONS: This study demonstrates that osteoarthritic glenoids with symmetric erosion have uniform subarticular bone density. However, asymmetric (B2) erosion patterns have potentially important regional variations in bone density and porosity, with the densest bone with the least porosity found posteroinferiorly or in the neoglenoid region.


Assuntos
Densidade Óssea , Osteoartrite/diagnóstico por imagem , Escápula/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Idoso , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/fisiopatologia , Porosidade , Falha de Prótese , Escápula/fisiopatologia , Articulação do Ombro/fisiopatologia , Tomografia Computadorizada por Raios X
20.
J Arthroplasty ; 30(12): 2128-32, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26162514

RESUMO

We aimed to determine whether not using a tourniquet in cemented TKA would affect migration of the tibial component measured by radiosterometric analysis (RSA). Seventy patients were randomized into a tourniquet group and a non-tourniquet group and using model-based RSA, the migration of the tibial component was analyzed. Primary and secondary outcome measures were maximum total point motion (MTPM) and translations and rotations. Follow-up period was 2 years. The tibial component was well fixated in both groups and no significant difference in migration between the two groups was detected (P=0.632). Mean MTPM (SD) was 0.47 mm (0.16) in the tourniquet group and 0.45 mm (0.21) in the non-tourniquet group. Absence of tourniquet indicates that stable fixation of the tibial component can be achieved in cemented TKA.


Assuntos
Artroplastia do Joelho , Torniquetes/estatística & dados numéricos , Idoso , Feminino , Humanos , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Análise Radioestereométrica , Tíbia/cirurgia , Resultado do Tratamento