1.
J Appl Clin Med Phys ; : e14469, 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39031843

RESUMO

PURPOSE: To evaluate the dosimetric impact on spatially fractionated radiation therapy (SFRT) plan quality due to intrafraction patient motion via multi-field MLC-based method for treating large and bulky (≥8 cm) unresectable tumors. METHODS: For large tumors, a cone beam CT-guided 3D conformal MLC-based SFRT method was utilized with 15 Gy prescription. An MLC GTV-fitting algorithm provided 1 cm diameter apertures with a 2 cm center-to-center distance at the isocenter. This generated a highly heterogeneous sieve-like dose distribution within an hour, enabling same-day SFRT treatment. Fifteen previously treated SFRT patients were analyzed (5 head & neck [H&N], 5 chest and lungs, and 5 abdominal and pelvis masses). For each plan, intrafraction motion errors were simulated by incrementally shifting original isocenters of each field in different x-, y-, and z-directions from 1 to 5 mm. The dosimetric metrics analyzed were: peak-to-valley-dose-ratio (PVDR), percentage of GTV receiving 7.5 Gy, GTV mean dose, and maximum dose to organs-at-risk (OARs). RESULTS: For ±1, ±2, ±3, ±4, and ±5 mm isocenter shifts: PVDR dropped by 3.9%, 3.8%, 4.0%, 4.1%, and 5.5% on average respectively. The GTV(V7.5) remained within 0.2%, and the GTV mean dose remained within 3.3% on average, compared to the original plans. The average PVDR drop for 5 mm shifts was 4.2% for H&N cases, 10% for chest and lung, and 2.2% for abdominal and pelvis cases. OAR doses also increased. The maximum dose to the spinal cord increased by up to 17 cGy in H&N plans, mean lung dose (MLD) changed was small for chest/lung, but the bowel dose varied up to 100 cGy for abdominal and pelvis cases. CONCLUSION: Due to tumor size, location, and characteristics of MLC-based SFRT, isocenter shifts of up to ±5 mm in different directions had moderate effects on PVDR for H&N and pelvic tumors and a larger effect on chest tumors. The dosimetric impact on OAR doses depended on the treatment site. Site-specific patient masks, Vac-Lok bags, and proper immobilization devices similar to SBRT/SRT setups should be used to minimize these effects.

2.
Strahlenther Onkol ; 199(1): 22-29, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35788694

RESUMO

PURPOSE: A markerless workflow for the treatment of breast cancer patients has been introduced and evaluated retrospectively. It includes surface-guided radiation therapy (SGRT)-only positioning for patients with small cone beam CT (CBCT) position corrections during the first five fractions. Prerequisites and the frequency of its clinical application were evaluated, as well as potential benefits in terms of treatment time and dose savings, the frequency of CBCT scans, and the accuracy of the positioning. METHODS: A group of 100 patients treated with the new workflow on two Versa HD linacs has been compared to a matched control group of patients treated with the former workflow, which included prepositioning with skin markings and lasers, SGRT and daily CBCT. The comparison was based on the evaluation of logfiles. RESULTS: Of the patients treated with the new workflow, 40% did not receive daily CBCT scans. This resulted in mean time savings of 97 s, 166 s and 239 s per fraction for the new workflow, for patients treated without daily CBCT and for SGRT-only fractions, respectively, when compared to the old workflow. Dose savings amounted to a weighted computed tomography dose index reduction of CTDIW = 2.56 cGy on average for normofractionated treatment and weekly CBCTs, while for patients not treated with daily CBCT, SGRT-based positioning accuracy was 5.2 mm for the mean translational magnitude, as evaluated by CBCT. CONCLUSION: For 40% of the patients, after five fractions with small CBCT corrections, the workflow could be changed to SGRT-only positioning with weekly CBCT. This leads to imaging dose and time savings and thus also reduced intrafraction motion, potentially increased patient throughput and patient comfort, while assuring appropriate positioning accuracy.


Assuntos
Neoplasias da Mama , Radioterapia Guiada por Imagem , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Posicionamento do Paciente/métodos , Fluxo de Trabalho , Estudos Retrospectivos , Radioterapia Guiada por Imagem/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
3.
J Appl Clin Med Phys ; 24(4): e13861, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36478148

RESUMO

The purpose of this study is to investigate the dosimetric accuracy of prostate SBRT when motion is considered. To account for target movement, motion compensation and gating techniques were investigated with PTV margins reduced to 2 mm. To allow for dosimetric measurements a Delta4 phantom, Gafchromic film, and Hexamotion motion platform were utilized. Four motion files were utilized that represent a range of motions. Analysis of measured prostate motions for fifteen patients was performed to ensure detected motions were similar to those previously reported and motion files utilized were suitable. Five patient plans were utilized to allow for the effects of MLC and target motion interplay to be investigated. For both motion compensation and gating techniques, plans were delivered to the stationary phantom and for each of four motion types with/without compensation/gating enabled. Using a 3%, 2 mm and 80% threshold gamma criteria, film measurements had an average pass rate of 80.5% for uncorrected deliveries versus 96.0% for motion compensated deliveries. For gated techniques average pass rates increased from 89.9% for uncorrected to 94.8% with gating enabled. Measurements with the Delta4 arrays were analyzed with a 3%, 2 mm and 10% threshold dose. An average pass rate of 83.8% was measured for uncorrected motions versus 94.8% with motion compensation. For the gated technique an average pass rate of 87.2% was found for uncorrected motions versus 96.9% with gating enabled. These results show that very high gamma pass rates are achievable when motion compensation or gating techniques are applied. When target motion is not accounted for shifts up to 5 mm in planned versus delivered isodose distributions were found. However, when motion compensation, or gated techniques were applied, much smaller differences between planned and delivered isodose distributions were found. With these techniques dose delivery accuracy is greatly improved, allowing for PTV margins to be reduced.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Masculino , Humanos , Próstata , Radiocirurgia/métodos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Movimento (Física) , Movimento , Radiometria/métodos , Dosagem Radioterapêutica
4.
J Appl Clin Med Phys ; 24(9): e14038, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37449391

RESUMO

Deep Inspiration Breath Hold (DIBH) is a respiratory-gating technique adopted in radiation therapy to lower cardiac irradiation. When performing DIBH treatments, it is important to have a monitoring system to ensure the patient's breath hold level is stable and reproducible at each fraction. In this retrospective study, we developed a system capable of monitoring DIBH breast treatments by utilizing cine EPID images taken during treatment. Setup error and intrafraction motion were measured for all fractions of 20 left-sided breast patients. All patients were treated with a hybrid static-IMRT technique, with EPID images from the static fields analyzed. Ten patients had open static fields and the other ten patients had static fields partially blocked with the multileaf collimator (MLC). Three image-processing algorithms were evaluated on their ability to accurately measure the chest wall position (CWP) in EPID images. CWP measurements were recorded along a 61-pixel region of interest centered along the midline of the image. The median and standard deviation of the CWP were recorded for each image. The algorithm showing the highest agreement with manual measurements was then used to calculate intrafraction motion and setup error. To measure intrafraction motion, the median CWP of the first EPID frame was compared with that of the subsequent EPID images of the treatment. The maximum difference was recorded as the intrafraction motion. The setup error was calculated as the difference in median CWP between the MV DRR and the first EPID image of the lateral tangential field. The results showed that the most accurate image-processing algorithm can identify the chest wall within 1.2 mm on both EPID and MV DRR images, and measures intrafraction motion and setup errors within 1.4 mm.


Assuntos
Neoplasias da Mama , Radioterapia de Intensidade Modulada , Humanos , Feminino , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Suspensão da Respiração , Dosagem Radioterapêutica , Mama , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias da Mama/radioterapia
5.
J Appl Clin Med Phys ; 23(11): e13740, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35906884

RESUMO

PURPOSE: Beam gating with deep inspiration breath hold (DIBH) usually depends on some external surrogate to infer internal target movement, and the exact internal movement is unknown. In this study, we tracked internal targets and characterized residual motion during DIBH treatment, guided by a surface imaging system, for gastrointestinal cancer. We also report statistics on treatment time. METHODS AND MATERIALS: We included 14 gastrointestinal cancer patients treated with surface imaging-guided DIBH volumetrically modulated arc therapy, each with at least one radiopaque marker implanted near or within the target. They were treated in 25, 15, or 10 fractions. Thirteen patients received treatment for pancreatic cancer, and one underwent separate treatments for two liver metastases. The surface imaging system monitored a three-dimensional surface with ± 3 mm translation and ± 3° rotation threshold. During delivery, a kilovolt image was automatically taken every 20° or 40° gantry rotation, and the internal marker was identified from the image. The displacement and residual motion of the markers were calculated. To analyze the treatment efficiency, the treatment time of each fraction was obtained from the imaging and treatment timestamps in the record and verify system. RESULTS: Although the external surface was monitored and limited to ± 3 mm and ± 3°, significant residual internal target movement was observed in some patients. The range of residual motion was 3-21 mm. The average displacement for this cohort was 0-3 mm. In 19% of the analyzed images, the magnitude of the instantaneous displacement was > 5 mm. The mean treatment time was 17 min with a standard deviation of 4 min. CONCLUSIONS: Precaution is needed when applying surface image guidance for gastrointestinal cancer treatment. Using it as a solo DIBH technique is discouraged when the correlation between internal anatomy and patient surface is limited. Real-time radiographic verification is critical for safe treatments.


Assuntos
Neoplasias Gastrointestinais , Neoplasias Pancreáticas , Humanos , Suspensão da Respiração , Movimento (Física) , Movimento , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/radioterapia , Neoplasias Gastrointestinais/diagnóstico por imagem , Neoplasias Gastrointestinais/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos
6.
J Appl Clin Med Phys ; 22(1): 218-225, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33378792

RESUMO

PURPOSE: Deep inspiration breath hold (DIBH) and respiratory gating (RG) are widely used to reduce movement of target and healthy organs caused by breathing during irradiation. We hypothesized that accuracy and efficiency comparable to DIBH can be achieved with RG for pancreas treatment. METHODS AND MATERIALS: Twenty consecutive patients with pancreatic cancer treated with DIBH (eight) or RG (twelve) volumetric modulated arc therapy during 2017-2019 were included in this study, with radiopaque markers implanted near or in the targets. Seventeen patients received 25 fractions, while the other three received 15 fractions. Only patients who could not tolerate DIBH received RG treatment. While both techniques relied on respiratory signals from external markers, internal target motions were monitored with kV X-ray imaging during treatment. A 3-mm external gating window was used for DIBH treatment; RG treatment was centered on end-expiration with a duty cycle of 40%, corresponding to an external gating window of 2-3 mm. During dose delivery, kV images were automatically taken every 20◦ or 40◦ gantry rotation, from which internal markers were identified. The marker displacement from their initial positions and the residual motion amplitudes were calculated. For the analysis of treatment efficiency, the treatment time of every session was calculated from the motion management waveform files recorded at the treatment console. RESULTS: Within one fraction, the displacement was 0-5 mm for DIBH and 0-6 mm for RG. The average magnitude of displacement for each patient during the entire course of treatment ranged 0-3 mm for both techniques. No statistically significant difference in displacement or residual motion was observed between the two techniques. The average treatment time was 15 min for DIBH and 17 min for RG, with no statistical significance. CONCLUSIONS: The accuracy and efficiency were comparable between RG and DIBH treatment for pancreas irradiation. RG is a feasible alternative strategy to DIBH.


Assuntos
Neoplasias Pancreáticas , Radioterapia de Intensidade Modulada , Suspensão da Respiração , Humanos , Pâncreas , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/radioterapia , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X
7.
J Appl Clin Med Phys ; 21(9): 96-106, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32691973

RESUMO

The Radixact® linear accelerator contains the motion Synchrony system, which tracks and compensates for intrafraction patient motion. For respiratory motion, the system models the motion of the target and synchronizes the delivery of radiation with this motion using the jaws and multi-leaf collimators (MLCs). It was the purpose of this work to determine the ability of the Synchrony system to track and compensate for different phantom motions using a delivery quality assurance (DQA) workflow. Thirteen helical plans were created on static datasets from liver, lung, and pancreas subjects. Dose distributions were measured using a Delta4® Phantom+ mounted on a Hexamotion® stage for the following three case scenarios for each plan: (a) no phantom motion and no Synchrony (M0S0), (b) phantom motion and no Synchrony (M1S0), and (c) phantom motion with Synchrony (M1S1). The LEDs were placed on the Phantom+ for the 13 patient cases and were placed on a separate one-dimensional surrogate stage for additional studies to investigate the effect of separate target and surrogate motion. The root-mean-square (RMS) error between the Synchrony-modeled positions and the programmed phantom positions was <1.5 mm for all Synchrony deliveries with the LEDs on the Phantom+. The tracking errors increased slightly when the LEDs were placed on the surrogate stage but were similar to tracking errors observed for other motion tracking systems such as CyberKnife Synchrony. One-dimensional profiles indicate the effects of motion interplay and dose blurring present in several of the M1S0 plans that are not present in the M1S1 plans. All 13 of the M1S1 measured doses had gamma pass rates (3%/2 mm/10%T) compared to the planned dose > 90%. Only two of the M1S0 measured doses had gamma pass rates > 90%. Motion Synchrony offers a potential alternative to the current, ITV-based motion management strategy for helical tomotherapy deliveries.


Assuntos
Radiometria , Radioterapia de Intensidade Modulada , Humanos , Pulmão , Movimento (Física) , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador
8.
J Appl Clin Med Phys ; 21(5): 48-55, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32196944

RESUMO

BACKGROUND AND PURPOSE: Multiple techniques can be used to assist with more accurate patient setup and monitoring during Stereotactic body radiation therapy (SBRT) treatment. This study analyzes the accuracy of 3D surface mapping with Surface-guided radiation therapy (SGRT) in detecting interfraction setup error and intrafraction motion during SBRT treatments of the lung and abdomen. MATERIALS AND METHODS: Seventy-one patients with 85 malignant thoracic or abdominal tumors treated with SBRT were analyzed. For initial patient setup, an alternating scheme of kV/kV imaging or SGRT was followed by cone beam computed tomography (CBCT) for more accurate tumor volumetric localization. The CBCT six degree shifts after initial setup with each method were recorded to assess interfraction setup error. Patients were then monitored continuously with SGRT during treatment. If an intrafractional shift in any direction >2 mm for longer than 2 sec was detected by SGRT, then CBCT was repeated and the recorded deltas were compared to those detected by SGRT. RESULTS: Interfractional shifts after SGRT setup and CBCT were small in all directions with mean values of <5 mm and < 0.5 degrees in all directions. Additionally, 25 patients had detected intrafraction motion by SGRT during a total of 34 fractions. This resulted in 25 (73.5%) additional shifts of at least 2 mm on subsequent CBCT. When comparing the average vector detected shift by SGRT to the resulting vector shift on subsequent CBCT, no significant difference was found between the two. CONCLUSIONS: Surface-guided radiation therapy provides initial setup within 5 mm for patients treated with SBRT and can be used in place of skin marks or planar kV imaging prior to CBCT. In addition, continuous monitoring with SGRT during treatment was valuable in detecting potentially clinically meaningful intrafraction motion and was comparable in magnitude to shifts from additional CBCT scans. PTV margin reduction may be feasible for SBRT in the lung and abdomen when using SGRT for continuous patient monitoring during treatment.


Assuntos
Radiocirurgia , Radioterapia Guiada por Imagem , Abdome/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Humanos , Pulmão , Movimento , Planejamento da Radioterapia Assistida por Computador
9.
J Appl Clin Med Phys ; 21(12): 109-119, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33140915

RESUMO

PURPOSE: The aim of this study was to provide a comprehensive assessment of patient intrafraction motion in linac-based frameless stereotactic radiosurgery (SRS) and radiotherapy (SRT). METHODS: A retrospective review was performed on 101 intracranial SRS/SRT patients immobilized with the Klarity stereotactic thermoplastic mask (compatible with the Brainlab frameless stereotactic system) and aligned on a 6 Degree of Freedom (DoF) couch with the Brainlab ExacTrac image guidance system. Both pretreatment and intrafraction correction data are provided as observed by the ExacTrac system. The effects of couch angle and treatment duration on positioning outcomes are also explored. RESULTS: Initial setup data for patients is shown to vary by up to ±4.18 mm, ±2.97°, but when corrected with a single x-ray image set with ExacTrac, patient positions are corrected to within ±2.11 mm, ±2.27°. Intrafraction patient motion is shown to be uniformly random and independent of both time and couch angle. Patient motion was also limited to within approximately 3 mm, 3° by the thermoplastic mask. CONCLUSIONS: Our results indicate that since patient intrafraction motion is unrelated to couch rotation and treatment duration, intrafraction patient monitoring in 6 DoF is required to minimize intracranial SRS/SRT margins.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirurgia , Humanos , Imageamento Tridimensional , Aceleradores de Partículas , Posicionamento do Paciente , Planejamento da Radioterapia Assistida por Computador , Erros de Configuração em Radioterapia/prevenção & controle , Estudos Retrospectivos , Rotação
10.
J Appl Clin Med Phys ; 21(12): 90-95, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33095971

RESUMO

PURPOSE: To report on the use of surface guided imaging during frameless intracranial stereotactic radiotherapy with automated delivery via HyperArcTM (Varian Medical Systems, Palo Alto, CA). METHODS: All patients received intracranial radiotherapy with HyperArcTM and were monitored for intrafraction motion by the AlignRT® (VisionRT, London, UK) surface imaging (SI) system. Immobilization was with the EncompassTM (Qfix, Avondale, PA) aquaplast mask device. AlignRT® log files were correlated with trajectory log files to correlate treatment parameters with SI reported offsets. SI reported offsets were correlated with gantry angle and analyzed for performance issues at non-zero couch angles and during camera-pod blockage during gantry motion. Demographics in the treatment management system were used to identify race and determine if differences in SI reported offsets are due to skin tone settings. RESULTS: A total of 981 fractions were monitored over 14 months and 819 were analyzed. The median AlignRT® reported motion from beginning to the end of treatment was 0.24 mm. The median offset before beam on at non-zero couch angles was 0.55 mm. During gantry motion when camera pods are blocked, the median magnitude was below 1 mm. Median magnitude of offsets at non-zero couch angles was not found to be significantly different for patients stratified by race. CONCLUSIONS: Surface image guidance is a viable alternative to scheduled mid-treatment imaging for monitoring intrafraction motion during stereotactic radiosurgery with automated delivery.


Assuntos
Radiocirurgia , Tomografia Computadorizada de Feixe Cônico , Humanos , Imobilização , Movimento (Física) , Posicionamento do Paciente , Planejamento da Radioterapia Assistida por Computador
11.
J Appl Clin Med Phys ; 21(8): 173-182, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32506590

RESUMO

PURPOSE: To present an open-source software (https://github.com/CHUSRadOncPhys/FluoMV) for monitoring intrafraction motion that is based on the visualization of superimposed contours of projected region-of-interests from DICOM RTSTRUCT files on cine-MV images acquired and displayed in real-time during radiation therapy delivery. Clinical use with prostate gold fiducial markers is presented. METHODS: Projections of regions of interest (ROI) in the reference frame of the electronic portal imaging device are computed offline for different gantry angles before the first treatment fraction. During treatment delivery, the contrast of portal images is automatically adjusted using a histogram equalization algorithm. The projections associated with the current gantry angle are then superimposed on the images in real time. This allows the therapist to evaluate if the imaged structures of interest remain within their respective contours during treatment delivery and to potentially interrupt the treatment if deemed necessary. The spatial accuracy of the method was evaluated by imaging a ball bearing phantom in a set-up where the position of the projected ROI is highly sensitive to gantry angle errors. The visibility of fiducial markers during one fraction of seven different volumetric modulated arc therapy (VMAT) prostate treatments is characterized. RESULTS: The geometric validation showed a negligible systematic error µ < 0.1 mm for the position of the projections. The random errors associated with the time accuracy of the gantry angle readout were characterized by standard deviations σ ≤ 0.6 mm. The VMAT clinical treatments showed that the fiducial markers were frequently visible, allowing for a meaningful clinical use. CONCLUSIONS: The results demonstrate that the method presented is sufficiently accurate to be used for intrafraction monitoring of patients. The fact that this method could be implemented on many modern linacs at little to no cost and with no additional dose delivered to the patients makes this solution very attractive for improving patient care and safety in radiation therapy.


Assuntos
Radioterapia de Intensidade Modulada , Marcadores Fiduciais , Humanos , Masculino , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador , Software
12.
J Appl Clin Med Phys ; 21(3): 184-191, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31981305

RESUMO

BACKGROUND: Fiducial markers are frequently used before treatment for image-guided patient setup in radiation therapy (RT), but can also be used during treatment for image-guided intrafraction motion detection. This report describes our implementation of automatic marker detection with periodic kV imaging (TrueBeam v2.5) to monitor and correct intrafraction motion during prostate RT. METHODS: We evaluated the reproducibility and accuracy of software fiducial detection using a phantom with 3 implanted fiducial markers. Clinical implementation for patients with intraprostatic fiducials receiving volumetric modulated arc therapy (VMAT) utilized periodic on-board kV imaging with 10 s intervals during treatment delivery. For each image, the software automatically identified fiducial locations and determined whether their distance relative to planned locations were within a 3 mm tolerance. Motion was corrected if either ≥2 fiducials in a single image or ≥1 fiducial in sequential images were out of tolerance. RESULTS: Phantom studies demonstrated poorer performance of linear fiducials compared to collapsible fiducials, and wide variability to accurately detect fiducials across eight software settings. For any given setting, results were relatively reproducible and precise to ~0.5 mm. Across 17 patients treated with a median of 20 fractions, the software recommended a shift in 44% of fractions, and a shift was actually implemented after visual confirmation of movement greater than the 3 mm threshold in 20% of fractions. Adjustment of our approach led to improved accuracy for the latter (n = 7) patient subset. On average, table repositioning added 3.0 ± 0.3 min to patient time on table. Periodic kV imaging increased skin dose by an estimated 1 cGy per treatment arc. CONCLUSIONS: Periodic kV imaging with automatic detection of motion during VMAT prostate treatments is commercially available, and can be successfully implemented to mitigate effects of intrafraction motion with careful attention to software settings.


Assuntos
Marcadores Fiduciais , Movimento , Imagens de Fantasmas , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Software , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Órgãos em Risco/efeitos da radiação , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/patologia , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/métodos
13.
J Appl Clin Med Phys ; 20(10): 67-73, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31478341

RESUMO

PURPOSE: To investigate the dosimetric impact of prostate intrafraction motion on proton double-scattering (DS) and uniform scanning (US) treatments using electromagnetic transponder-based prostate tracking data in simulated treatment deliveries. METHODS: In proton DS delivery, the spread-out Bragg peak (SOBP) is created almost instantaneously by the constant rotation of the range modulator. US, however, delivers each entire energy layer of the SOBP sequentially from distal to proximal direction in time, which can interplay with prostate intrafraction motion. This spatiotemporal interplay during proton treatment was simulated to evaluate its dosimetric impact. Prostate clinical target volume (CTV) dose was obtained by moving CTV through dose matrices of the energy layers according to prostate-motion traces. Fourteen prostate intrafraction motion traces of each of 17 prostate patients were used in the simulated treatment deliveries. Both single fraction dose-volume histograms (DVHs) and fraction-cumulative DVHs were obtained for both 2 Gy per fraction and 7.25 Gy per fraction stereotactic body radiotherapy (SBRT). RESULTS: The simulation results indicated that CTV dose degradation depends on the magnitude and direction of prostate intrafraction motion and is patient specific. For some individual fractions, prescription dose coverage decreased in both US and DS treatments, and hot and cold spots inside the CTV were observed in the US results. However, fraction-cumulative CTV dose coverage showed much reduced dose degradation for both DS and US treatments for both 2 Gy per fraction and SBRT simulations. CONCLUSIONS: This study indicated that CTV dose inhomogeneity may exist for some patients with severe prostate intrafraction motion during US treatments. However, there are no statistically significant dose differences between DS and US treatment simulations. Cumulative dose of multiple-fractions significantly reduced dose uncertainties.


Assuntos
Simulação por Computador , Movimento , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Terapia com Prótons/métodos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Masculino , Órgãos em Risco/efeitos da radiação , Prognóstico , Dosagem Radioterapêutica
14.
J Appl Clin Med Phys ; 20(5): 37-43, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30933428

RESUMO

PURPOSE: Beam gating with deep inspiration breath hold (DIBH) has been widely used for motion management in radiotherapy. Normally it relies on some external surrogate for estimating the internal target motion, while the exact internal motion is unknown. In this study, we used the intrafraction motion review (IMR) application to directly track an internal target and characterized the residual motion during DIBH treatment for pancreatic cancer patients through their full treatment courses. METHODS AND MATERIALS: Eight patients with pancreatic cancer treated with DIBH volumetric modulated arc therapy in 2017 and 2018 were selected for this study, each with some radiopaque markers (fiducial or surgical clips) implanted near or inside the target. The Varian Real-time Position Management (RPM) system was used to monitor the breath hold, represented by the anterior-posterior displacement of an external surrogate, namely reflective markers mounted on a plastic block placed on the patient's abdomen. Before each treatment, a cone beam computed tomography (CBCT) scan under DIBH was acquired for patient setup. For scan and treatment, the breath hold reported by RPM had to lie within a 3 mm window. IMR kV images were taken every 20° or 40° gantry rotation during dose delivery, resulting in over 5000 images for the cohort. The internal markers were manually identified in the IMR images. The residual motion amplitudes of the markers as well as the displacement from their initial positions located in the setup CBCT images were analyzed. RESULTS: Even though the external markers indicated that the respiratory motion was within 3 mm in DIBH treatment, significant residual internal target motion was observed for some patients. The range of average motion was from 3.4 to 7.9 mm, with standard deviation ranging from 1.2 to 3.5 mm. For all patients, the target residual motions seemed to be random with mean positions around their initial setup positions. Therefore, the absolute target displacement relative to the initial position was small during DIBH treatment, with the mean and the standard deviation 0.6 and 2.9 mm, respectively. CONCLUSIONS: Internal target motion may differ from external surrogate motion in DIBH treatment. Radiographic verification of target position at the beginning and during each fraction is necessary for precise RT delivery. IMR can serve as a useful tool to directly monitor the internal target motion.


Assuntos
Suspensão da Respiração , Movimento , Neoplasias Pancreáticas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Órgãos em Risco/efeitos da radiação , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Prognóstico , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
15.
J Appl Clin Med Phys ; 20(6): 91-98, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31095866

RESUMO

PURPOSE: To evaluate the accuracy of monitoring intrafraction motion during stereotactic radiotherapy with the optical surface monitoring system. Prior studies showing a false increase in the magnitude of translational offsets at non-coplanar couch positions prompted the vendor to implement software changes. This study evaluated two software improvements intended to address false offsets. METHODS: The vendor implemented two software improvements: a volumetric (ACO) rather than planar calibration and, approximately 6 months later, an improved calibration workflow (CIB) designed to better compensate for thermal drift. Offsets relative to the reference position, obtained at table angle 0 following image-guided setup, were recorded before beam-on at each table position and at the end of treatment the table returned to 0° for patients receiving SRT. RESULTS: Prior to ACO, between ACO and CIB, and after CIB, 223, 155, and 436 fractions were observed respectively. The median magnitude of translational offsets at the end of treatment was similar for all three intervals: 0.29, 0.33, and 0.27 mm. Prior to ACO, the offset magnitude for non-zero table positions had a median of 0.79 mm and was found to increase with increasing distance from isocenter to the anterior patient surface. After ACO, the median magnitude was 0.74 mm, but the dependence on surface-to-isocenter distance was eliminated. After CIB, the median magnitude for non-zero table positions was reduced to 0.57 mm. CONCLUSION: Ongoing improvements in software and calibration procedures have decreased reporting of false offsets at non-zero table angles. However, the median magnitude for non-zero table angles is larger than that observed at the end of treatment, indicating that accuracy remains better when the table is not rotated.


Assuntos
Neoplasias Encefálicas/cirurgia , Posicionamento do Paciente , Imagens de Fantasmas , Radiocirurgia/instrumentação , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Cirurgia Assistida por Computador/instrumentação , Neoplasias Encefálicas/patologia , Humanos , Imobilização , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Software
16.
J Appl Clin Med Phys ; 19(1): 17-24, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29119677

RESUMO

PURPOSE: Full face and neck thermoplastic masks provide standard-of-care immobilization for patients receiving H&N IMRT. However, these masks are uncomfortable and increase skin dose. The purpose of this pilot trial was to investigate the feasibility and setup accuracy of minimal face and neck mask immobilization with optical surface guidance. METHODS: Twenty patients enrolled onto this IRB-approved protocol. Patients were immobilized with masks securing only forehead and chin. Shoulder movement was restricted by either moldable cushion or hand held strap retractors. Positional information, including isocenter location and CT skin contours, were imported to a commercial surface image guidance system. Patients typically received standard-of-care IMRT to 60-70 Gy in 30-33 fractions. Patients were first set up to surface markings with optical image guidance referenced to regions of interest (ROIs) on simulation CT images. Positioning was confirmed by in-room CBCT. Following six-dimensional robotic couch correction, a new optical real-time surface image was acquired to track intrafraction motion and to serve as a reference surface for setup at the next treatment fraction. Therapists manually recorded total treatment time as well as couch shifts based on kV imaging. Intrafractional ROI motion tracking was automatically recorded by the optical image guidance system. Patient comfort was assessed by self-administered surveys. RESULTS: Setup error was measured as six-dimensional shifts (vertical/longitudinal/lateral/rotation/pitch/roll). Mean error values were -0.51 ± 2.42 mm, -0.49 ± 3.30 mm, 0.23 ± 2.58 mm, -0.15 ± 1.01o , -0.02 ± 1.19o , and 0.06 ± 1.08o , respectively. Average treatment time was 21.6 ± 8.4 mins). Subjective comfort during surface-guided treatment was confirmed on patient surveys. CONCLUSION: These pilot results confirm feasibility of minimal mask immobilization combined with commercially available optical image guidance. Patient acceptance of minimal mask immobilization has been encouraging. Follow-up validation, with direct comparison to standard mask immobilization, appears warranted.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Imobilização/métodos , Órgãos em Risco/efeitos da radiação , Posicionamento do Paciente , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Erros de Configuração em Radioterapia/prevenção & controle , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/métodos
17.
Rep Pract Oncol Radiother ; 23(5): 398-401, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30127681

RESUMO

AIM: To investigate the intrafraction movement of the esophagus using fiducial markers. BACKGROUND: Studies on intrafraction esophageal motion using the fiducial markers are scarce. MATERIALS AND METHODS: We retrospectively analyzed patients with clinical T1N0 esophageal cancer who had received fiducial markers at our hospital between July 2007 and December 2013. Real-Time Position Management System to track the patient's respiration was used, and each patient underwent three-dimensional computed tomography of the resting expiratory and inspiratory level. We used the center of the marker to calculate the distance between the expiratory and inspiratory breath-holds, which were measured with the radiotherapy treatment planning system in three directions: left-right (LR), superior-inferior (SI), and anterior-posterior (AP). The movements at each site were compared with the Kruskal-Wallis analysis and Wilcoxon rank sum test with a Bonferroni correction. RESULTS: A total of 101 patients with 201 fiducial markers were included. The upper, middle and lower thoracic positions had 40, 77, and 84 markers, respectively. The mean absolute magnitudes of the shifts (standard deviation) were 0.18 (0.19) cm, 0.68 (0.46) cm, and 0.24 (0.24) cm in the LR, SI, and AP directions, respectively. From the cumulative frequency distribution, we assumed that 0.35 cm LR, 0.8 cm SI, and 0.3 cm AP in the upper; 0.5 cm LR, 1.55 cm SI, and 0.55 cm AP in the middle; and 0.75 cm LR, 1.9 cm SI, and 0.95 cm AP in the lower thoracic esophagus covered 95% of the cases. CONCLUSIONS: The internal margin based on the site of esophagus was estimated.

18.
Strahlenther Onkol ; 193(6): 459-465, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28197655

RESUMO

OBJECTIVE: In image-guided EBRT of the prostate, transperineal ultrasound (US) probes exert pressure on the perineum both during planning and treatment. Through tissue deformation and relaxation, this causes target and risk organ displacement and drift. In this study, prefraction shift and intrafraction drift of the prostate are quantified during robotic transperineal 4DUS. METHODS: The position of the prostate was recorded for different positions of the probe before treatment in 10 patients (16 series of measurements). During treatment (15 patients, 273 fractions), intrafraction motion of the prostate was tracked (total of 27 h and 24 min) with the transperineal probe in place. RESULTS: Per 1 mm shift of the US probe in the cranial direction, a displacement of the prostate by 0.42 ± 0.09 mm in the cranial direction was detected. The relationship was found to be linear (R² = 0.97) and highly significant (p < 0.0001). After initial contact of the probe and the perineum (no pressure), a shift of the probe of about 5-10 mm was typically necessary to achieve good image quality, corresponding to a shift of the prostate of about 2-4 mm in the cranial direction. Tissue compression and prostate displacement were well visible. During treatment, the prostate drifted at an average rate of 0.075 mm/min in the cranial direction (p = 0.0014). CONCLUSION: The pressure applied by a perineal US probe has a quantitatively similar impact on prostate displacement as transabdominal pressure. Shifts are predominantly in the cranial direction (typically 2-4 mm) with some component in the anterior direction (typically <1 mm). Slight probe pressure can improve image quality, but excessive probe pressure can distort the surrounding anatomy and potentially move risk organs closer to the high-dose area.


Assuntos
Artefatos , Fracionamento da Dose de Radiação , Aumento da Imagem , Posicionamento do Paciente , Próstata/diagnóstico por imagem , Próstata/efeitos da radiação , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radioterapia Guiada por Imagem/instrumentação , Transdutores , Ultrassonografia/instrumentação , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Órgãos em Risco/efeitos da radiação , Períneo/diagnóstico por imagem , Pressão , Garantia da Qualidade dos Cuidados de Saúde , Dosagem Radioterapêutica
19.
Strahlenther Onkol ; 193(10): 840-847, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28733724

RESUMO

PURPOSE: Anchored electromagnetic transponders for tumor motion monitoring during lung radiotherapy were clinically evaluated. First, intrafractional motion patterns were analyzed as well as their interfractional variations. Second, intra- and interfractional changes of the geometric transponder positions were investigated. MATERIALS AND METHODS: Intrafractional motion data from 7 patients with an upper or middle lobe tumor and three implanted transponders each was used to calculate breathing amplitudes, overall motion amount and motion midlines in three mutual perpendicular directions and three-dimensionally (3D) for 162 fractions. For 6 patients intra- and interfractional variations in transponder distances and in the size of the triangle defined by the transponder locations over the treatment course were determined. RESULTS: Mean 3D values of all fractions were up to 4.0, 4.6 and 3.4 mm per patient for amplitude, overall motion amount and midline deviation, respectively. Intrafractional transponder distances varied with standard deviations up to 3.2 mm, while a maximal triangle shrinkage of 36.5% over 39 days was observed. CONCLUSIONS: Electromagnetic real-time motion monitoring was feasible for all patients. Detected respiratory motion was on average modest in this small cohort without lower lobe tumors, but changes in motion midline were of the same size as the amplitudes and greater midline motion can be observed in some fractions. Intra- and interfractional variations of the geometric transponder positions can be large, so for reliable motion management correlation between transponder and tumor motion needs to be evaluated per patient.


Assuntos
Neoplasias Pulmonares/radioterapia , Magnetometria/instrumentação , Monitorização Ambulatorial/instrumentação , Posicionamento do Paciente/instrumentação , Radioterapia Conformacional/instrumentação , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Movimento (Física) , Posicionamento do Paciente/métodos , Reprodutibilidade dos Testes , Mecânica Respiratória , Sensibilidade e Especificidade
20.
J Appl Clin Med Phys ; 18(6): 130-136, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28960696

RESUMO

BACKGROUND: Kilovoltage Intrafraction Monitoring (KIM) is a method which determines the three-dimensional position of the prostate from two-dimensional kilovoltage (kV) projections taken during linac based radiotherapy treatment with real-time feedback. Rectal displacement devices (RDDs) allow for improved rectal dosimetry during prostate cancer treatment. This study used KIM to perform a preliminary investigation of prostate intrafraction motion observed in patients with an RDD in place. METHODS: Ten patients with intermediate to high-risk prostate cancer were treated with a Rectafix RDD in place during two boost fractions of 9.5-10 Gy delivered using volumetric modulated arc therapy (VMAT) on Clinac iX and Truebeam linacs. Two-dimensional kV projections were acquired during treatment. KIM software was used following treatment to determine the displacement of the prostate over time. The displacement results were analyzed to determine the percentage of treatment time the prostate spent within 1 mm, between 1 and 2 mm, between 2 and 3 mm and greater than 3 mm from its initial position. RESULTS: KIM successfully measured displacement for 19 prostate stereotactic boost fractions. The prostate was within 1 mm of its initial position for 84.8%, 1-2 mm for 14%, 2-3 mm 1.2% and ≥3 mm only 0.4% of the treatment time. CONCLUSIONS: In this preliminary study using KIM, KIM was successfully used to measure prostate intrafraction motion, which was found to be small in the presence of a rectal displacement device. TRIAL REGISTRATION: The Hunter New England Human Research Ethics Committee reference number is 14/08/20/3.01.


Assuntos
Movimento , Aceleradores de Partículas , Imagens de Fantasmas , Neoplasias da Próstata/cirurgia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Reto/efeitos da radiação , Idoso , Algoritmos , Marcadores Fiduciais , Humanos , Masculino , Pelve/efeitos da radiação , Neoplasias da Próstata/patologia , Radiometria/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Software