Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Biomed Opt ; 24(1): 1-8, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30612379

RESUMO

We present a multicolor fluorescence microscope system, under a selective plane illumination microscopy (SPIM) configuration, using three continuous wave-lasers and a single-channel-detection camera. The laser intensities are modulated with three time-delayed pulse trains that operate synchronously at one third of the camera frame rate, allowing a sequential excitation and an image acquisition of up to three different biomarkers. The feasibility of this imaging acquisition mode is demonstrated by acquiring single-plane multicolor images of living hyphae of Neurospora crassa. This allows visualizing simultaneously the localization and dynamics of different cellular components involved in apical growth in living hyphae. The configuration presented represents a noncommercial, cost-effective alternative microscopy system for the rapid and simultaneous acquisition of multifluorescent images and can be potentially useful for three-dimensional imaging of large biological samples.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Microscopia de Fluorescência/instrumentação , Microscopia de Fluorescência/métodos , Neurospora crassa/metabolismo , Biomarcadores/metabolismo , Cor , Desenho de Equipamento , Corantes Fluorescentes/química , Proteínas de Fluorescência Verde/química , Lasers , Luz , Proteínas Luminescentes/química , Rodaminas/química , Proteína Vermelha Fluorescente
2.
Biomed Opt Express ; 8(11): 4919-4920, 2017 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29188090

RESUMO

[This corrects the article on p. 1430 in vol. 8, PMID: 28663839.].

3.
Biomed Opt Express ; 8(3): 1430-1440, 2017 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28663839

RESUMO

In the present paper we show the optoacoustic (OA) response of two solutions of gold nanorods dispersed in distilled water (0.8 mg/ml) and hosted in tissue-like phantoms by using small arrays of high-power diode lasers [corrected] at 870 and 905 nm as excitation sources. The high-power diode lasers [corrected] are coupled to a 7-to-1 optical fiber bundle with output diameter of 675 µm. Each solution of gold nanorods exhibits an absorption peak close to the operating wavelength, i.e. ~860 nm and ~900 nm, respectively, to optimize the generation of OA signals. The phantoms are made of agar, intralipid and hemoglobin to simulate a soft biological tissue with reduced properties of scattering. Three 3-mm diameter tubes done in the phantoms at different depths (0.9 cm, 1.8 cm, and 2.7 cm) have been filled with gold nanorods. In this way, OA signals with appreciable SNR are generated at different depths in the phantoms. The high OA response exhibited by gold nanorods suggests their application in OA spectroscopy as exogenous contrast agents to detect and monitor emerging diseases like metastasis and arteriosclerotic plaques.

4.
Biomed Opt Express ; 7(7): 2586-96, 2016 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-27446691

RESUMO

Accurate monitoring of blood oxy-saturation level (SO2 ) in human breast tissues is clinically important for predicting and evaluating possible tumor growth at the site. In this work, four different non-invasive frequency-domain photoacoustic (PA) imaging modalities were compared for their absolute SO2 characterization capability using an in-vitro sheep blood circulation system. Among different PA modes, a new WM-DPAR imaging modality could estimate the SO2 with great accuracy when compared to a commercial blood gas analyzer. The developed WM-DPARI theory was further validated by constructing SO2 tomographic images of a blood-containing plastisol phantom.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA