Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Sensors (Basel) ; 23(16)2023 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-37631732

RESUMO

Accurate and reliable measurements of optical properties are crucial for a wide range of industrial and commercial applications. However, external illumination fluctuations can often make these measurements challenging to obtain. This work proposes a new technique based on digital lock-in processing that enables the use of CCD spectrometers in optical spectroscopy applications, even in uncontrolled lighting conditions. This approach leverages digital lock-in processing, performed on each pixel of the spectrometer's CCD simultaneously, to mitigate the impact of external optical interferences. The effectiveness of this method is demonstrated by testing and recovering the spectrum of a yellow LED subjected to other light sources in outdoor conditions, corresponding to a Signal-to-Noise Ratio of -70.45 dB. Additionally, it was possible to demonstrate the method's applicability for the spectroscopic analysis of gold nanoparticles in outdoor conditions. These results suggest that the proposed technique can be helpful for a wide range of optical measurement techniques, even in challenging lighting conditions.

2.
Sensors (Basel) ; 23(4)2023 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-36850672

RESUMO

A key milestone for the pervasive diffusion of wireless sensing nodes for smart monitoring of water quality and quantity in distribution networks is the simplification of the installation of sensors. To address this aspect, we demonstrate how two basic contactless sensors, such as piezoelectric transducers and strip electrodes (in a longitudinal interdigitated configuration to sense impedance inside and outside of the pipe with potential for impedimetric leak detection), can be easily clamped on plastic pipes to enable the measurement of multiple parameters without contact with the fluid and, thus, preserving the integrity of the pipe. Here we report the measurement of water flow rate (up to 24 m3/s) and temperature with ultrasounds and of the pipe filling fraction (capacitance at 1 MHz with ~cm3 resolution) and ionic conductivity (resistance at 20 MHz from 700 to 1400 µS/cm) by means of impedance. The equivalent impedance model of the sensor is discussed in detail. Numerical finite-element simulations, carried out to optimize the sensing parameters such as the sensing frequency, confirm the lumped models and are matched by experimental results. In fact, a 6 m long, 30 L demonstration hydraulic loop was built to validate the sensors in realistic conditions (water speed of 1 m/s) monitoring a pipe segment of 0.45 m length and 90 mm diameter (one of the largest ever reported in the literature). Tradeoffs in sensors accuracy, deployment, and fabrication, for instance, adopting single-sided flexible PCBs as electrodes protected by Kapton on the external side and experimentally validated, are discussed as well.

3.
Sensors (Basel) ; 23(1)2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36616660

RESUMO

A frequency downscaling technique for enhancing the accuracy of analog lock-in amplifier (LIA) architectures in giant magneto-impedance (GMI) sensor applications is presented in this paper. As a proof of concept, the proposed method is applied to two different LIA topologies using, respectively, analog and switching-based multiplication for phase-sensitive detection. Specifically, the operation frequency of both the input and the reference signals of the phase-sensitive detector (PSD) block of the LIA is reduced through a subsampling process using sample-and-hold (SH) circuits. A frequency downscaling from 200 kHz, which is the optimal operating frequency of the employed GMI sensor, to 1 kHz has been performed. In this way, the proposed technique exploits the inherent advantages of analog signal multiplication at low frequencies, while the principle of operation of the PSD remains unaltered. The circuits were assembled using discrete components, and the frequency downscaling proposal was experimentally validated by comparing the measurement accuracy with the equivalent conventional circuits. The experimental results revealed that the error in the signal magnitude measurements was reduced by a factor of 8 in the case of the analog multipliers and by a factor of 21 when a PSD based on switched multipliers was used. The error in-phase detection using a two-phase LIA was also reduced by more than 25%.

4.
Sensors (Basel) ; 22(14)2022 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-35891137

RESUMO

The need for affordable low-power devices has led MEMS-based thermal emitters to become an interesting option for optical gas sensors. Since these emitters have a low thermal mass, they can be easily modulated and combined with a lock-in amplifier for detection. In this paper, we show that the signal measured by a lock-in amplifier from a thermal emitter that varies its temperature periodically can have different spectral profiles, depending on the reference signal used. These virtual emitters appear because the Fourier series expansion of the emitted radiance, as a function of time, has different coefficients for each wavelength, and this spectral signature, which is different for each harmonic, can be retrieved using a reference signal that corresponds to its frequency. In this study, the effect is first proved theoretically and then is measured experimentally. For this purpose, we performed measurements with an IR camera provided with six different spectral filters of a modulated emitter, in combination with lock-in amplification via software. Finally, we show a potential application of this effect using multiple virtual emitters to gain spectral selectivity and distinguish between two gases, CO2 and CH4.

5.
Appl Psychophysiol Biofeedback ; 47(3): 213-222, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35704121

RESUMO

Pulse rate variability is a physiological parameter that has been extensively studied and correlated with many physical ailments. However, the phase relationship between inter-beat interval, IBI, and breathing has very rarely been studied. Develop a technique by which the phase relationship between IBI and breathing can be accurately and efficiently extracted from photoplethysmography (PPG) data. A program based on Lock-in Amplifier technology was written in Python to implement a novel technique, Dynamic Phase Extraction. It was tested using a breath pacer and a PPG sensor on 6 subjects who followed a breath pacer at varied breathing rates. The data were then analyzed using both traditional methods and the novel technique (Dynamic Phase Extraction) utilizing a breath pacer. Pulse data was extracted using a PPG sensor. Dynamic Phase Extraction (DPE) gave the magnitudes of the variation in IBI associated with breathing [Formula: see text] measured with photoplethysmography during paced breathing (with premature ventricular contractions, abnormal arrhythmias, and other artifacts edited out). [Formula: see text] correlated well with two standard measures of pulse rate variability: the Standard Deviation of the inter-beat interval (SDNN) (ρ = 0.911) and with the integrated value of the Power Spectral Density between 0.04 and 0.15 Hz (Low Frequency Power or LF Power) (ρ = 0.885). These correlations were comparable to the correlation between the SDNN and the LF Power (ρ = 0.877). In addition to the magnitude [Formula: see text], Dynamic Phase Extraction also gave the phase between the breath pacer and the changes in the inter-beat interval (IBI) due to respiratory sinus arrythmia (RSA), and correlated well with the phase extracted using a Fourier transform (ρ = 0.857). Dynamic Phase Extraction can extract both the phase between the breath pacer and the changes in IBI due to the respiratory sinus arrhythmia component of pulse rate variability ([Formula: see text], but is limited by needing a breath pacer.


Assuntos
Arritmia Sinusal Respiratória , Processamento de Sinais Assistido por Computador , Eletrocardiografia , Frequência Cardíaca/fisiologia , Humanos , Fotopletismografia/métodos , Taxa Respiratória
6.
Proc Jpn Acad Ser B Phys Biol Sci ; 97(5): 236-260, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33980754

RESUMO

Ultrashort visible-near infrared (NIR) pulse generation and its applications to ultrafast spectroscopy are discussed. Femtosecond pulses of around 800 nm from a Ti:sapphire laser are used as a pump of an optical parametric amplifier (OPA) in a non-collinear configuration to generate ultrashort visible (500-780 nm) pulses and deep-ultraviolet (DUV, 259-282 nm) pulses. The visible-NIR pulses and DUV pulses were compressed to 3.9 fs and 10.4 fs, respectively, and used to elucidate various ultrafast dynamics in condensed matter with a sub-10 fs resolution by pump-probe measurements. We have also developed a 128-channel lock-in amplifier. The combined system of the world-shortest visible pulse from the OPA and the lock-in amplifier with the world-largest channel-number can clarify the sub-10 fs-dynamics in condensed matter. This system clarified structural changes in an excited state, reaction intermediate, and a transition state. This is possible even during molecular vibration and reactions via a real-time-resolved vibronic spectrum, which provides molecular structural change information. Also, ultrafast dynamics in exotic materials like carbon nanotubes, topological insulators, and novel solar battery systems have been clarified. Furthermore, the carrier-envelope phase in the ultrashort pulse has been controlled and measured.


Assuntos
Espectrofotometria/instrumentação , Desenho de Equipamento , Raios Infravermelhos , Cinética , Lasers , Luz , Nanotubos de Carbono/química , Energia Solar , Fatores de Tempo , Vibração
7.
Sensors (Basel) ; 19(16)2019 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-31405249

RESUMO

In this work, we report on the design of a wide-band digital lock-in amplifier (DLIA) of up to 65 MHz and its application for electrical impedance measurements in microfluidic devices. The DLIA is comprised of several dedicated technologies. First, it features a fully differential analog circuit, which includes a preamplifier with a low input noise of 4.4 nV/√Hz, a programmable-gain amplifier with a gain of 52 dB, and an anti-aliasing, fully differential low-pass filter with -76 dB stop-band attenuation. Second, the DLIA has an all-digital phase lock loop, which features a phase deviation of less than 0.02° throughout the frequency range. The phase lock loop utilizes an equally accurate period-frequency measurement, with a sub-ppm precision of frequency detection. Third, a modified clock link is implemented in the DLIA to improve the signal-to-noise ratio of the analog-to-digital converter affected by clock jitter of up to 20 dBc. A series of measurements were performed to characterize the DLIA, and the results showed an accurate performance. Additionally, impedance measurements of standard-size microparticles were performed by frequency sweep from 300 kHz to 30 MHz, using the DLIA in a microfluidic device. Different diameters of microparticle could be accurately distinguished according to the relative impedance at 2.5 MHz. The results confirm the promising applications of the DLIA in microfluidic electrical impedance measurements.

8.
Sensors (Basel) ; 19(21)2019 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-31652819

RESUMO

For successful intra-articular injection therapy, it is essential to accurately position the tip of the injection needle into the target joint area while administering the drug into the affected tissue. In this study, we investigated the feasibility of a monopolar injection needle and lock-in amplifier (LIA)-based impedance measurement system for detecting the tissue type where the needle tip is located. After positioning the monopolar injection needle tip into the dermis, hypodermis, or muscle layer of pork tissue, the electrical impedance was measured in the frequency range of 10 Hz to 10 kHz. We observed a difference in the results based on the tissue type where the needle was positioned (p-value < 0.01). Therefore, the monopolar injection needle with electrical impedance measurement can be used to improve intra-articular injection therapy through non-destructive and real-time monitoring of the needle position in the tissues.


Assuntos
Impedância Elétrica , Músculos/fisiologia , Amplificadores Eletrônicos , Animais , Derme/fisiologia , Eletrodos , Músculos/diagnóstico por imagem , Agulhas , Suínos , Ultrassonografia
9.
Sensors (Basel) ; 19(23)2019 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-31779162

RESUMO

This paper presents a fully integrated Gm-C low pass filter (LPF) based on a current steering Gm reduction-tuning technique, specifically designed to operate as the output stage of a SoC lock-in amplifier. To validate this proposal, a first-order and a second-order single-ended topology were integrated into a 1.8 V to 0.18 µm CMOS (Complementary Metal-Oxide-Semiconductor) process, showing experimentally a tuneable cutoff frequency that spanned five orders of magnitude, from tens of mHz to kHz, with a constant current consumption (below 3 µA/pole), compact size (<0.0140 mm2/pole), and a dynamic range better than 70 dB. Compared to state-of-the-art solutions, the proposed approach exhibited very competitive performances while simultaneously fully satisfying the demanding requirements of on-chip portable measurement systems in terms of highly efficient area and power. This is of special relevance, taking into account the current trend towards multichannel instruments to process sensor arrays, as the total area and power consumption will be proportional to the number of channels.

10.
Sensors (Basel) ; 18(2)2018 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-29415477

RESUMO

We report the experimental results on a new infrared fiber-optic pyrometer for very localized and high-speed temperature measurements ranging from 170 to 530 °C using low-noise photodetectors and high-gain transimpedance amplifiers with a single gain mode in the whole temperature range. We also report a shutter based on an optical fiber switch which is optically powered to provide a reference signal in an optical fiber pyrometer measuring from 200 to 550 °C. The tests show the potential of remotely powering via optical means a 300 mW power-hungry optical switch at a distance of 100 m, avoiding any electromagnetic interference close to the measuring point.

11.
Sensors (Basel) ; 17(11)2017 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-29135951

RESUMO

Lock-in amplification (LIA) is an effective approach for recovery of weak signal buried in noise. Determination of the input signal amplitude in a classical dual-phase LIA is based on incoherent detection which leads to a biased estimation at low signal-to-noise ratio. This article presents, for the first time to our knowledge, a new architecture of LIA involving phase estimation with a linear-circular regression for coherent detection. The proposed phase delay estimate, between the input signal and a reference, is defined as the maximum-likelihood of a set of observations distributed according to a von Mises distribution. In our implementation this maximum is obtained with a Newton Raphson algorithm. We show that the proposed LIA architecture provides an unbiased estimate of the input signal amplitude. Theoretical simulations with synthetic data demonstrate that the classical LIA estimates are biased for SNR of the input signal lower than -20 dB, while the proposed LIA is able to accurately recover the weak signal amplitude. The novel approach is applied to an optical sensor for accurate measurement of NO 2 concentrations at the sub-ppbv level in the atmosphere. Side-by-side intercomparison measurements with a commercial LIA (SR830, Stanford Research Inc., Sunnyvale, CA, USA ) demonstrate that the proposed LIA has an identical performance in terms of measurement accuracy and precision but with simplified hardware architecture.

12.
Sensors (Basel) ; 16(11)2016 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-27845710

RESUMO

Weak voltage signals cannot be reliably measured using currently available logging tools when these tools are subject to high-temperature (up to 200 °C) environments for prolonged periods. In this paper, we present a digital lock-in amplifier (DLIA) capable of operating at temperatures of up to 200 °C. The DLIA contains a low-noise instrument amplifier and signal acquisition and the corresponding signal processing electronics. The high-temperature stability of the DLIA is achieved by designing system-in-package (SiP) and multi-chip module (MCM) components with low thermal resistances. An effective look-up-table (LUT) method was developed for the lock-in amplifier algorithm, to decrease the complexity of the calculations and generate less heat than the traditional way. The performance of the design was tested by determining the linearity, gain, Q value, and frequency characteristic of the DLIA between 25 and 200 °C. The maximal nonlinear error in the linearity of the DLIA working at 200 °C was about 1.736% when the equivalent input was a sine wave signal with an amplitude of between 94.8 and 1896.0 nV and a frequency of 800 kHz. The tests showed that the DLIA proposed could work effectively in high-temperature environments up to 200 °C.

13.
Sensors (Basel) ; 16(4)2016 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-27089339

RESUMO

A complementary metal-oxide semiconductor (CMOS) lock-in pixel to observe stimulated Raman scattering (SRS) using a high speed lateral electric field modulator (LEFM) for photo-generated charges and in-pixel readout circuits is presented. An effective SRS signal generated after the SRS process is very small and needs to be extracted from an extremely large offset due to a probing laser signal. In order to suppress the offset components while amplifying high-frequency modulated small SRS signal components, the lock-in pixel uses a high-speed LEFM for demodulating the SRS signal, resistor-capacitor low-pass filter (RC-LPF) and switched-capacitor (SC) integrator with a fully CMOS differential amplifier. AC (modulated) components remained in the RC-LPF outputs are eliminated by the phase-adjusted sampling with the SC integrator and the demodulated DC (unmodulated) components due to the SRS signal are integrated over many samples in the SC integrator. In order to suppress further the residual offset and the low frequency noise (1/f noise) components, a double modulation technique is introduced in the SRS signal measurements, where the phase of high-frequency modulated laser beam before irradiation of a specimen is modulated at an intermediate frequency and the demodulation is done at the lock-in pixel output. A prototype chip for characterizing the SRS lock-in pixel is implemented and a successful operation is demonstrated. The reduction effects of residual offset and 1/f noise components are confirmed by the measurements. A ratio of the detected small SRS to offset a signal of less than 10(-)5 is experimentally demonstrated, and the SRS spectrum of a Benzonitrile sample is successfully observed.

14.
Sensors (Basel) ; 16(3)2016 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-26999138

RESUMO

Photothermal techniques allow the detection of characteristics of material without invading it. Researchers have developed hardware for some specific Phase and Amplitude detection (Lock-In Function) applications, eliminating space and unnecessary electronic functions, among others. This work shows the development of a Digital Lock-In Amplifier based on a Field Programmable Gate Array (FPGA) for low-frequency applications. This system allows selecting and generating the appropriated frequency depending on the kind of experiment or material studied. The results show good frequency stability in the order of 1.0 × 10(-9) Hz, which is considered good linearity and repeatability response for the most common Laboratory Amplitude and Phase Shift detection devices, with a low error and standard deviation.

15.
Sensors (Basel) ; 15(6): 13110-20, 2015 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-26053754

RESUMO

A significant improvement of the response characteristics of a redox chemical gas sensor (chemiresistor) constructed with a single ZnO coated silica nanospring has been achieved with the technique of lock-in signal amplification. The comparison of DC and analog lock-in amplifier (LIA) AC measurements of the electrical sensor response to toluene vapor, at the ppm level, has been conducted. When operated in the DC detection mode, the sensor exhibits a relatively high sensitivity to the analyte vapor, as well as a low detection limit at the 10 ppm level. However, at 10 ppm the signal-to-noise ratio is 5 dB, which is less than desirable. When operated in the analog LIA mode, the signal-to-noise ratio at 10 ppm increases by 30 dB and extends the detection limit to the ppb range.

16.
Artigo em Inglês | MEDLINE | ID: mdl-26401427

RESUMO

AC bridge techniques commonly used for precision impedance measurements have been adapted to develop an eddy current sensor for rail defect detection. By using two detection coils instead of just one as in a conventional sensor, we can balance out the large baseline signals corresponding to a normal rail. We have significantly enhanced the detection sensitivity of the eddy current method by detecting and demodulating the differential signal of the two coils induced by rail defects, using a digital lock-in amplifier algorithm. We have also explored compensating for the lift-off effect of the eddy current sensor due to vibrations by using the summing signal of the detection coils to measure the lift-off distance. The dominant component of the summing signal is a constant resulting from direct coupling from the excitation coil, which can be experimentally determined. The remainder of the summing signal, which decreases as the lift-off distance increases, is induced by the secondary eddy current. This dependence on the lift-off distance is used to calibrate the differential signal, allowing for a more accurate characterization of the defects. Simulated experiments on a sample rail have been performed using a computer controlled X-Y moving table with the X-axis mimicking the train's motion and the Y-axis mimicking the train's vibrational bumping. Experimental results demonstrate the effectiveness of the new detection method.

17.
Am J Phys ; 81(9): 712, 2013 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-24659823

RESUMO

Photoacoustic (PA) imaging techniques have recently attracted much attention and can be used for noninvasive imaging of biological tissues. Most PA imaging systems in research laboratories use the time domain method with expensive nanosecond pulsed lasers that are not affordable for most educational laboratories. Using an intensity modulated light source to excite PA signals is an alternative technique, known as the frequency domain method, with a much lower cost. In this paper, we describe a simple frequency domain PA system and demonstrate its imaging capability. The system provides opportunities not only to observe PA signals in tissue phantoms, but also to acquire hands-on skills in PA signal detection. It also provides opportunities to explore the underlying mechanisms of the PA effect.

18.
Micromachines (Basel) ; 14(3)2023 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-36985103

RESUMO

Laser interferometer technology is used in the precision positioning stage as an encoder. For better resolution, laser interferometers usually work with interpolation devices. According to the interpolation factor, these devices can convert an orthogonal sinusoidal signal into several square-wave signals via digital processing. The bandwidth of the processing will be the limitation of the moving speed of the positioning stage. Therefore, the user needs to make a trade-off between the interpolation factor and the moving speed. In this investigation, a novel analog interpolation method for a heterodyne laser interferometer has been proposed. This method is based on the principle of the lock-in amplifier (LIA). By using the proposed interpolation method, the bandwidth of the laser encoder system can be independent of the interpolation factor. This will be a significant benefit for the ultra-high resolution encoder system and the laser interferometers. The concept, design, and experiment are revealed in this manuscript. The experimental results show that the proposed interpolation method can reach nanometer resolution with a heterodyne laser interferometer, and the bandwidth of the signal is independent of the resolution.

19.
Micromachines (Basel) ; 14(3)2023 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-36984945

RESUMO

The internal electric field coupling noise of a quartz flexible accelerometer (QFA) restricts the improvement of the measurement accuracy of the accelerometer. In this paper, the internal electric field coupling mechanism of a QFA is studied, an electric field coupling detection noise model of the accelerometer is established, the distributed capacitance among the components of the QFA is simulated, the structure of the detection noise transfer system of different carrier modulation differential capacitance detection circuits is analyzed, and the influence of each transfer chain on the detection noise is discussed. The simulation results of electric field coupling detection noise show that the average value of detection noise can reach 41.7 µg, which is close to the effective resolution of the QFA, 50 µg. This confirms that electric field coupling detection noise is a non-negligible factor affecting the measurement accuracy of the accelerometer. A method of adding a high-pass filter to the front of the phase-shifting circuit is presented to suppress the noise of electric field coupling detection. This method attenuates the average value of the detected noise by about 78 dB, and reduces the average value of the detected noise to less than 0.1 µg, which provides a new approach and direction for effectively breaking through the performance of the QFA.

20.
Anal Chim Acta ; 1269: 341424, 2023 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-37290859

RESUMO

Impedance cytometry is a well-established technique for counting and analyzing single cells, with several advantages, such as convenience, high throughput, and no labeling required. A typical experiment consists of the following steps: single-cell measurement, signal processing, data calibration, and particle subtype identification. At the beginning of this article, we compared commercial and self-developed options extensively and provided references for developing reliable detection systems, which are necessary for cell measurement. Then, a number of typical impedance metrics and their relationships to biophysical properties of cells were analyzed with respect to the impedance signal analysis. Given the rapid advances of intelligent impedance cytometry in the past decade, this article also discussed the development of representative machine learning-based approaches and systems, and their applications in data calibration and particle identification. Finally, the remaining challenges facing the field were summarized, and potential future directions for each step of impedance detection were discussed.


Assuntos
Aprendizado de Máquina , Impedância Elétrica , Citometria de Fluxo/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA