RESUMO
In conventional electrochemiluminescence (ECL) systems, the presence of the competitive cathodic hydrogen evolution reaction (HER) in aqueous electrolytes is typically considered to be a side reaction, leading to a reduced ECL efficiency and stability due to H2 generation and aggregation at the electrode surface. However, the significant role of adsorbed hydrogen (H*) as a key intermediate, formed during the Volmer reaction in the HER process, has been largely overlooked. In this study, employing the luminol-H2O2 system as a model, we for the first time demonstrate a novel H*-mediated coreactant activation mechanism, which remarkably enhances the ECL intensity. H* facilitates cleavage of the O-O bond in H2O2, selectively generating highly reactive hydroxyl radicals for efficient ECL reactions. Experimental investigations and theoretical calculations demonstrate that this H*-mediated mechanism achieves superior coreactant activation compared to the conventional direct electron transfer pathway, which unveils a new pathway for coreactant activation in the ECL systems.
RESUMO
Electrochemiluminescence (ECL) is the generation of light induced by an electrochemical reaction, driven by electricity. Here, an all-optical ECL (AO-ECL) system is developped, which triggers ECL by the illumination of electrically autonomous "integrated" photoelectrochemical devices immersed in the electrolyte. Because these systems are made using small and cheap devices, they can be easily prepared and readily used by any laboratories. They are based on commercially available p-i-n Si photodiodes (≈1 unit-1), coupled with well-established ECL-active and catalytic materials, directly coated onto the component leads by simple and fast wet processes. Here, a Pt coating (known for its high activity for reduction reactions) and carbon paint (known for its optimal ECL emission properties) are deposited at cathode and anode leads, respectively. In addition to its optimized light absorption properties, using the commercial p-i-n Si photodiode eliminates the need for a complicated manufacturing process. It is shown that the device can emit AO-ECL by illumination with polychromatic (simulated sunlight) or monochromatic (near IR) light sources to produce visible photons (425 nm) that can be easily observed by the naked eye or recorded with a smartphone camera. These low-cost off-grid AO-ECL devices open broad opportunities for remote photodetection and portable bioanalytical tools.
RESUMO
Exploring novel electrochemiluminescence (ECL) co-reaction accelerators to construct ultrasensitive sensing systems is a prominent focus for developing advanced ECL sensors. However, challenges still remain in finding highly efficient accelerators and understanding their promoting mechanisms. In this paper, ZIF-67@MXene nanosheet composites, with highly conductive in-plane structure and confined-stable pore/channel, are designed to act as high-efficient co-reaction accelerators and achieve a significant enhancement in the luminol-H2O2 based ECL system. Mechanism investigation suggests that hydroxyl radicals (·OH) and singlet oxygen (1O2) can be selectively and preferentially generated on ZIF-67@MXene due to the stable and efficient absorption of ·OH and 1O2, leading to a remarkable enhancement in the ECL efficiency of luminol (830%). Finally, by designing a plasmonic NH2-MIL-88@Pd nanozyme, an "on-off" switch immunosensor is constructed for the detection of prostate-specific antigen (PSA). Based on the multiple signal amplification effect, the linear detection range for PSA is expanded by three orders of magnitude. The detection limit is also improved from 1.44 × 10-11 to 9.1 × 10-13 g mL-1. This work proposes an effective method for the preparation of highly efficient co-reaction accelerators and provides a new strategy for the sensitive detection of cancer markers.
RESUMO
Conventional luminol co-reactant electrochemiluminescence (ECL) systems suffer from low stability and accuracy due to factors such as the ease of decomposition of hydrogen peroxide and inefficient generation of reactive oxygen species (ROS) from dissolved oxygen. Inspired by the luminol ECL mechanism mediated by oxygen evolution reaction (OER), the nickel-cobalt layered double hydroxide (NiCo-LDH) hollow nanocages with hollow structure and defect state are used as co-reaction promoters to enhance the ECL emission from the luminol-H2 O system. Thanks to the hollow structure and defect state, NiCo-LDH hollow nanocages show excellent OER catalytic activity, which can stabilize and efficiently produce ROS and enhance the ECL emission. Additionally, mechanistic exploration suggests that the ROS involved in the co-reaction of the luminol-H2 O system are derived from the OER reaction process, and there is a positive correlation between ECL intensity and the OER catalytic activity of the co-reaction promoter. The selection of catalysts with excellent OER catalytic activity is a key factor in improving ECL emission. Finally, a dual-mode immunosensor is constructed for the detection and analysis of alpha-fetoprotein (AFP) based on the promoting effect of NiCo-LDH hollow nanocages on the luminol-H2 O ECL system.
RESUMO
The estimation of the postmortem interval (PMI) is one of the key challenges for forensic anthropologists. Although there are several methods referenced for this purpose, none is sufficiently effective. One of the main reasons justifying the complexity of this task is the influence of several taphonomic factors.The study of the Luminol technique has stood out as a promising method for estimating PMI, complementing the existing methods, since it is an economic, easy and reproducible method that operates as a presumptive test. However, it is not known which taphonomic factors can influence the results obtained by this technique.The aim of this study is to test the influence of taphonomic factors, such as temperature, humidity, soil type and pH, on the estimation of the PMI by the Luminol technique.In order to test the influence of the referred factors, a sample consisting of 30 clavicles, with known and similar PMI, collected from autopsies, was distributed as evenly as possible by six vases and buried with different decomposition conditions for a period of 12 months. After the exhumation and sample preparation, the Luminol technique was applied.It was possible to clearly observe differences in the results. Thus, according to our research, it is possible to conclude that the results obtained by the application of Luminol are influenced by taphonomic factors. Therefore, the context in which a body is found should always be considered for applying this technique.
Assuntos
Luminol , Mudanças Depois da Morte , Humanos , Autopsia , Exumação , Temperatura , Patologia Legal/métodosRESUMO
Postmortem interval (PMI) estimation represents a significant challenge in the forensic sciences, particularly when dealing with human skeletal remains. A screening protocol for distinguishing possible remains of forensic interest is a crucial tool for judicial purposes. In this context, luminol chemiluminescence emerges as a promising method, with low overall costs and required time. This method is primarily used as a presumptive test, based on the understanding that the intensity of the chemiluminescence reactions decreases with an increase in the postmortem interval, thus underlining its practical implications.This research aims to expand previous research on the potential of luminol chemiluminescence, evaluating its usefulness in estimating PMI. Our sample comprised 239 human clavicles, with known PMI. The luminol solution was sprayed on each powder bone sample in a dark room, observed by the naked eye and photographed. The intensity of the chemiluminescence reaction was measured using a binary and a 5-level scale.The present results reveal that this method is a suitable tool for PMI estimation as a presumptive test, reducing time and costs in criminal investigations. The findings underscore the high sensitivity of luminol chemiluminescence for detecting recent PMI but also highlight a notable incidence of false positives. Thus, our results confirm luminol chemiluminescence as a powerful tool for dating time of death, particularly for identifying forensic relevant remains. Still, the relatively low specificity indicates that it should be complemented with additional tests for further confirmation and scientific validation of the remains' forensic relevance.
RESUMO
We developed a sensing strategy that mimics the bead-based electrogenerated chemiluminescence immunoassay. However, instead of the most common metal complexes, such as Ru or Ir, the luminophore is luminol. The electrogenerated chemiluminescence of luminol was promoted by in situ electrochemical generation of hydrogen peroxide at a boron-doped diamond electrode. The electrochemical production of hydrogen peroxide was achieved in a carbonate solution by an oxidation reaction, while at the same time, microbeads labelled with luminol were deposited on the electrode surface. For the first time, we proved that was possible to obtain light emission from luminol without its direct oxidation at the electrode. This new emission mechanism is obtained at higher potentials than the usual luminol electrogenerated chemiluminescence at 0.3-0.5 V, in conjunction with hydrogen peroxide production on boron-doped diamond at around 2-2.5 V (vs Ag/AgCl).
RESUMO
The majority of previously reported cathodic electrochemiluminescence (ECL) systems often required very negative potential to be carried out, which has greatly limited their applications in the sensing field. Screening high-performance cathodic ECL systems with low triggering potential is a promising way to broaden their applications. In this work, rhenium disulfide nanosheets (ReS2 NS) have been revealed as an efficient co-promoter to realize low-triggering-potential cathodic luminol ECL. One strong cathodic ECL signal appeared at a potential of -0.3 V and one anodic ECL peak was obtained at -0.15 V under the reverse potential scan, which were caused by electrogenerated reactive oxygen species (ROS) from hydrogen peroxide. The generation of strong luminol ECL at low potential was the result of the electrocatalytic effect of ReS2 NS on the reduction of H2O2. The scavenging effect of uric acid (UA) on the ROS could significantly inhibit the cathodic ECL. As a result, an ECL sensor was proposed, which showed outstanding performance for the detection of UA in the range of 10 nM to 0.1 mM with a low detection limit of 1.53 nM. Moreover, the ECL sensor was successfully applied in the sensitive detection of UA in real samples. This work provides a new avenue to establish a low-potential cathodic ECL system, which will sufficiently expand the potential application of cathodic ECL in the sensing field.
RESUMO
Disruption of the thyroid hormone (TH) system is connected with diverse adverse health outcomes in wildlife and humans. It is crucial to develop and validate suitable in vitro assays capable of measuring the disruption of the thyroid hormone (TH) system. These assays are also essential to comply with the 3R principles, aiming to replace the ex vivo tests often utilised in the chemical assessment. We compared the two commonly used assays applicable for high throughput screening [Luminol and Amplex UltraRed (AUR)] for the assessment of inhibition of thyroid peroxidase (TPO, a crucial enzyme in TH synthesis) using several cell lines and 21 compounds from different use categories. As the investigated cell lines derived from human and rat thyroid showed low or undetectable TPO expression, we developed a series of novel cell lines overexpressing human TPO protein. The HEK-TPOA7 model was prioritised for further research based on the high and stable TPO gene and protein expression. Notably, the Luminol assay detected significant peroxidase activity and signal inhibition even in Nthy-ori 3-1 and HEK293T cell lines without TPO expression, revealing its lack of specificity. Conversely, the AUR assay was specific to TPO activity. Nevertheless, despite the different specificity, both assays identified similar peroxidation inhibitors. Over half of the tested chemicals with diverse structures and from different use groups caused TPO inhibition, including some widespread environmental contaminants suggesting a potential impact of environmental chemicals on TH synthesis. Furthermore, in silico SeqAPASS analysis confirmed the high similarity of human TPO across mammals and other vertebrate classes, suggesting the applicability of HEK-TPOA7 model findings to other vertebrates.
Assuntos
Iodeto Peroxidase , Iodeto Peroxidase/antagonistas & inibidores , Iodeto Peroxidase/metabolismo , Iodeto Peroxidase/genética , Humanos , Animais , Ratos , Células HEK293 , Luminol , Ensaios de Triagem em Larga Escala/métodos , Oxazinas , Glândula Tireoide/efeitos dos fármacos , Glândula Tireoide/metabolismo , Linhagem Celular , Proteínas de Ligação ao Ferro/metabolismo , Autoantígenos/metabolismo , Disruptores Endócrinos/toxicidadeRESUMO
A new smartphone-based chemiluminescence method has been introduced for the quantitative analysis of CL-20 (Hexanitroazaisowuertzitan) explosive. The solvent mixture, oxidizer agent, and concentration of the reactants were optimized using statistical procedures. CL-20 explosive showed a quenching effect on the chemiluminescence intensity of the luminol-NaClO reaction in the solvent mixture of DMSO/H2O. A smartphone was used as a detector to record the light intensity of chemiluminescence reaction as a video file. The recorded video file was converted to an analytical signal as intensity luminescence-time curve by a written code in MATLAB software. Dynamic range and limit of detection of the proposed method were obtained 2.0-240.0 and 1.1 mgâ L-1, respectively, in optimized concentrations 1.5 × 10-3 molâ L-1 luminol and 1.0 × 10-2 molâ L-1 NaClO. Precursors TADB, HBIW, and TADNIW in CL-20 explosive synthesis did not show interference in measurement the CL-20 purity. The analysis of CL-20 spiked samples of soil and water indicated the satisfactory ability of the method in the analysis of real samples. The interaction of CL-20 molecules and OCl- ions is due to quench of chemiluminescence reaction of the luminol-NaClO.
Assuntos
Medições Luminescentes , Luminol , Smartphone , Medições Luminescentes/métodos , Medições Luminescentes/instrumentação , Luminol/química , Substâncias Explosivas/análise , Luminescência , Limite de DetecçãoRESUMO
A solid-state electrochemiluminescence (ECL) sensor was fabricated by immobilizing luminol, a classical luminescent reagent, on a Zn-Co-ZIF carbon fiber-modified electrode for the rapid and sensitive detection of procymidone (PCM) in vegetable samples. The sensor was created by sequentially modifying the glassy carbon electrode with Zn-Co-ZIF carbon fiber (Zn-Co-ZIF CNFs), Pt@Au NPs, and luminol. Zn-Co-ZIF CNFs, prepared through electrospinning and high-temperature pyrolysis, possessed a large specific surface area and porosity, making it suitable as carrier and electron transfer accelerator in the system. Pt@Au NPs demonstrated excellent catalytic activity, effectively enhancing the generation of active substances. The ECL signal was significantly amplified by the combination of Zn-Co-ZIF CNFs and Pt@Au NPs, which can subsequently be diminished by procymidone. The ECL intensity decreased proportionally with the addition of procymidone, displaying a linear relationship within the concentration range 1.0 × 10-13 to 1.0 × 10-6 mol L-1 (R2 = 0.993). The sensor exhibited a detection limit of 3.3 × 10-14 mol L-1 (S/N = 3) and demonstrated outstanding reproducibility and stability, making it well-suited for the detection of procymidone in vegetable samples.
Assuntos
Cobalto , Técnicas Eletroquímicas , Ouro , Limite de Detecção , Medições Luminescentes , Luminol , Verduras , Zinco , Luminol/química , Verduras/química , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Medições Luminescentes/métodos , Zinco/química , Ouro/química , Cobalto/química , Nanopartículas Metálicas/química , Platina/química , Carbono/química , Eletrodos , Substâncias Luminescentes/química , Contaminação de Alimentos/análise , Reprodutibilidade dos TestesRESUMO
A novel luminol derivative of N-(1,4-dioxo-1,2,3,4-tetrahydrophthalazin-5-yl)acrylamide (DTA) with excellent luminescence efficiency was designed and synthesized. Furthermore, a molecularly imprinted electrochemiluminescence sensor (MIECLS) was fabricated to detect ultratrace levels of human serum albumin (HSA) with high sensitivity and selectivity via a click reaction. The molecularly imprinted polymers (MIPs) were formed on the electrode surface via electropolymerization with HSA as a template molecule and catechol as a monomer. In the detection process, the -SH group of HSA on the electrode and the C = C bond of acryloyl group in DTA formed a new C-S bond via the Michael addition reaction to construct the MIECLS. The higher the concentration of HSA, the greater electrochemiluminescence (ECL) intensity measured. Taking advantage of MIECLS for ECL detection (scanning potential, - 0.4 to 0.5 V), there was a good linear relationship between ECL intensity and the logarithm of HSA concentration in the range 5 × 10-9 to 1 × 10-13 mg mL-1. The limit of detection (LOD) of the sensor was 1.05 × 10-15 mg mL-1. The sensor exhibited outstanding selectivity and stability. The sensor was applied to detect HSA in human serum with good recoveries of 97.7-105.2%. The concentration of HSA was detected by electrochemical method using the gating effect of MIP.
Assuntos
Acrilamida , Luminol , Humanos , Técnicas Eletroquímicas , Eletrodos , Albumina Sérica HumanaRESUMO
A chemiluminescence (CL) method for determination of glutathione (GSH) was developed with magnetic nanoparticle-decorated metal organic frameworks (Fe3O4 NPs@Cu-TATB). The composite material was synthesized via a hydrothermal method and glutathione (GSH) can be detected by both visual and chemiluminescence (CL) methods. The synthesized Fe3O4 NPs@Cu-TATB exhibited excellent catalytic activity in the luminol-H2O2 CL system. The mechanism revealed that three types of oxygen-containing radicals (ROS) were generated in this system. As GSH can reduce the catalytic effect of generated ROS radicals, the inhibiting CL signal was produced in the Fe3O4 NPs@Cu-TATB-luminol-H2O2 system. Based on the established CL system, the detection limits for GSH using CL and visual methods were found to be 0.3 µM and 0.7 µM, respectively. This low-cost and convenient detection method can be applied to the determination of GSH content in human blood.
Assuntos
Glutationa , Peróxido de Hidrogênio , Limite de Detecção , Medições Luminescentes , Luminol , Nanopartículas de Magnetita , Estruturas Metalorgânicas , Glutationa/sangue , Glutationa/química , Glutationa/análise , Humanos , Estruturas Metalorgânicas/química , Medições Luminescentes/métodos , Luminol/química , Nanopartículas de Magnetita/química , Peróxido de Hidrogênio/química , Cobre/química , CatáliseRESUMO
A method is presented for chemiluminescence resonance energy transfer (CRET) using APTES-Fe3O4 as a highly efficient energy acceptor with strong magnetic effectiveness over extended distances, while an Au@BSA-luminol composite acts as the donor. In order to boost the chemiluminescence reactions, CuO nanoparticles were successfully employed. The distance between the donor and acceptor is a crucial factor in the occurrence of the CRET phenomenon. A sensitive and high-throughput sandwich chemiluminescence immunosensor has been developed accordingly with a linear range of 1.0 × 10-7 g/L to 6.0 × 10-5 g/L and a limit of detection of 0.8 × 10-7 g/L. The CRET-based sandwich immunosensor has the potential to be implemented to early cancer diagnosis because of its high sensitivity in detecting Nanog, fast analysis (30 min), and simplicity. Furthermore, this approach has the potential to be adapted for the recognition of other antigen-antibody immune complexes by utilizing the corresponding antigens and their selective antibodies.
Assuntos
Biomarcadores Tumorais , Proteína Homeobox Nanog , Humanos , Imunoensaio/métodos , Biomarcadores Tumorais/sangue , Biomarcadores Tumorais/imunologia , Biomarcadores Tumorais/análise , Proteína Homeobox Nanog/imunologia , Células-Tronco Neoplásicas/imunologia , Limite de Detecção , Medições Luminescentes/métodos , Cobre/química , Anticorpos Imobilizados/imunologia , Ouro/química , Técnicas Biossensoriais/métodos , Nanopartículas Metálicas/químicaRESUMO
Simple development of an electrochemiluminescence (ECL) immunosensor for convenient detection of tumor biomarker is of great significance for early cancer diagnosis, treatment evaluation, and improving patient survival rates and quality of life. In this work, an immunosensor is demonstrated based on an enhanced ECL signal boosted by nanochannel-confined Au nanomaterial, which enables sensitive detection of the tumor biomarker-carcinoembryonic antigen (CEA). Vertically-ordered mesoporous silica film (VMSF) with a nanochannel array and amine groups was rapidly grown on a simple and low-cost indium tin oxide (ITO) electrode using the electrochemically assisted self-assembly (EASA) method. Au nanomaterials were confined in situ on the VMSF through electrodeposition, which catalyzed both the conversion of dissolved oxygen (O2) to reactive oxygen species (ROS) and the oxidation of a luminol emitter and improved the electrode active surface. The ECL signal was enhanced fivefold after Au nanomaterial deposition. The recognitive interface was fabricated by covalent immobilization of the CEA antibody on the outer surface of the VMSF, followed with the blocking of non-specific binding sites. In the presence of CEA, the formed immunocomplex reduced the diffusion of the luminol emitter, resulting in the reduction of the ECL signal. Based on this mechanism, the constructed immunosensor was able to provide sensitive detection of CEA ranging from 1 pg·mL-1 to 100 ng·mL-1 with a low limit of detection (LOD, 0.37 pg·mL-1, S/N = 3). The developed immunosensor exhibited high selectivity and good stability. ECL determination of CEA in fetal bovine serum was achieved.
Assuntos
Técnicas Biossensoriais , Antígeno Carcinoembrionário , Técnicas Eletroquímicas , Ouro , Medições Luminescentes , Luminol , Oxigênio , Antígeno Carcinoembrionário/sangue , Antígeno Carcinoembrionário/análise , Luminol/química , Ouro/química , Imunoensaio/métodos , Oxigênio/química , Técnicas Eletroquímicas/métodos , Humanos , Medições Luminescentes/métodos , Técnicas Biossensoriais/métodos , Nanoestruturas/química , Nanopartículas Metálicas/química , Eletrodos , Limite de DetecçãoRESUMO
In this paper, sphingomyelin (SM) is detected by a polyaniline hydrogel and Au nanoparticles with enzyme modified electrode (GCE/PAniH/AuNPs@enzyme). After a battery of enzymic degradation, SM can generate H2O2 and enhance the electrochemiluminescence (ECL) response of luminol, which endows the sensor with good sensitivity, specifiity and repeatability. Additionally, the proposed ECL biosensor displays good analytical performances with a wide range from 10.0 µg·mL-1 to 250.0 µg·mL-1 as well as a low detection limit of 3.50 µg·mL-1 (S/N = 3). When the ECL biosensor is used in the detection of SM in milk samples, satisfactory results are obtained, indicating that PAniH/AuNPs@enzyme will serve as a promising ECL material in the applications of H2O2-related bioassay in the future.
Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Animais , Ouro , Esfingomielinas , Leite , Hidrogéis , Peróxido de Hidrogênio , Medições Luminescentes , Luminol , Técnicas Biossensoriais/métodos , Limite de Detecção , Técnicas EletroquímicasRESUMO
Sensitive detection methods for nitrite (NO2-) and nitrate (NO3-) ions are essential to understand the nitrogen cycle and for environmental protection and public health. Herein, we report a detection method that combines ion-chromatographic separation of NO2- and NO3-, on-line photochemical conversion of these ions to peroxynitrite (ONOO-) by irradiation with a 222 nm excimer lamp, and chemiluminescence from the reaction between luminol and ONOO-. The detection limits for NO2- and NO3- were 0.01 and 0.03 µM, respectively, with linear ranges of 0.010-2.0 and 0.10-3.0 µM, respectively, at an injection volume of 1 µL. The results obtained by the proposed method for seawater analysis corresponded with those of a reference method (AutoAnalyzer based on the Griess reaction). As luminol chemiluminescence can measure ONOO- at picomolar concentrations, our method is expected to be able to detect NO2- and NO3- at picomolar concentrations owing to the high conversion ratio to ONOO- (>60%), assuming that contamination and background chemiluminescence issues can be resolved. This method has the potential to emerge as an innovative technology for NO2- and NO3- detection in various samples.
Assuntos
Nitratos , Nitritos , Nitritos/análise , Nitratos/análise , Luminol/química , Ácido Peroxinitroso/química , Luminescência , Dióxido de Nitrogênio , Água do Mar , CromatografiaRESUMO
A luminol based chemiluminescent trimeric system, namely 2,3-dihydro-5,8-di(thiophen-2-yl)phthalazine-1,4-dione (T2B-Lum), bearing thiophene rings as donor units and 2,3-dihydrophthalazine-1,4-dione as an acceptor unit was synthesized in two steps via donor-acceptor-donor approach using two different methods. It was found that T2B-Lum emits chemiluminescent light when exposed to H2O2 in a basic medium, and the presence of substituents and the type of aromatic ring bearing chemiluminescent active group have a direct effect on the compound's sensitivity. Among the members of a large family of metal ions, fluorescent and chemiluminescent T2B-Lum exhibited high sensitivity to Cu2+ and Fe3+ ions. Except for other metal cations (silver(I), cadmium(II), cobalt(II), iron(III), lithium(I), magnesium(II), manganese(II), nickel(II), zinc(II)), it has been observed that T2B-Lum is mostly sensitive to copper(II) ions with a detection limit value of 2.2 × 10- 3 M. On the other hand, T2B-Lum was also found to exhibit a high sensitivity to extremely dilute aqueous solutions (e.g., 1:50.000 dilution) of blood samples, making it a promising candidate for use in forensic applications.
RESUMO
Atropine (AT) is an anticholinergic drug. AT is abundantly in Datura plant seeds. Fe3 O4 @Zn/Mg MOF (Fe3 O4 @MOF) composite was synthesized. The compound had a high peroxidase-like activity in a chemiluminescence (CL) reaction. Addition of AT quenched CL. The linear range and limit of detection were 5-600 µg L-1 and 2 × 10-2 µg L-1 . This method is fast, reversible, and selective, without biodegradability effects, high accuracy, and precision for measuring AT in the Datura plant.
Assuntos
Luminol , Peróxidos , Atropina , Luminescência , Medições Luminescentes/métodos , Limite de Detecção , Zinco , Peróxido de HidrogênioRESUMO
Chemiluminescence (CL) reactions are widely used for the detection and quantification of many types of analytes. Laccase has previously been proposed in CL reactions; however, its light emission behaviour has not been characterized. This study was conducted to characterize the laccase-luminol system, determine its kinetic parameters, and analyze the effects of protein and OH- concentration on the CL signal. Laccase from Coriolopsis gallica was combined with different concentrations of luminol (125 nM to 4 mM), and the enzyme kinetics were evaluated using diverse kinetic models. The laccase-luminol system was able to produce CL without an intermediate molecule, but it exhibited substrate-inhibition behaviour. A two-site random model was used and suggested that when the first luminol molecule was bound to the active site, laccase affinity for the second luminol molecule was increased. This inhibition effect could be avoided using a low luminol concentration. At 5 µM luminol concentration, 1 mg/ml (0.13 U) laccase is needed to achieve nearly 90% of the maximum CL signal, suggesting that the available luminol could not bind to all active sites. Furthermore, the concentration of NaOH negatively affected the CL signal. The laccase-luminol system represents an alternative to existing CL systems, with potential uses in molecular detection and quantification.