Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Global Spine J ; 13(5): 1286-1292, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34235996

RESUMO

STUDY DESIGN: Prospective single-cohort analysis. OBJECTIVES: To compare the outcomes/complications of 2 robotic systems for spine surgery. METHODS: Adult patients (≥18-years-old) who underwent robot-assisted spine surgery from 2016-2019 were assessed. A propensity score matching (PSM) algorithm was used to match Mazor X to Renaissance cases. Preoperative CT scan for planning and an intraoperative O-arm for screw evaluation were preformed. Outcomes included screw accuracy, robot time/screw, robot abandonment, and radiation. Screw accuracy was measured using Vitrea Core software by 2 orthopedic surgeons. Screw breach was measured according to the Gertzbein/Robbins classification. RESULTS: After PSA, a total of 65 patients (Renaissance: 22 vs. X: 43) were included. Patient/operative factors were similar between robot systems (P > .05). The pedicle screw accuracy was similar between robots (Renaissance: 1.1%% vs. X: 1.3%, P = .786); however, the S2AI screw breach rate was significantly lower for the X (Renaissance: 9.5% vs. X: 1.2%, P = .025). Robot time per screw was not statistically different (Renaissance: 4.6 minutes vs. X: 3.9 minutes, P = .246). The X was more reliable with an abandonment rate of 2.3% vs. Renaissance:22.7%, P = .007. Radiation exposure were not different between robot systems. Non-robot related complications including dural tear, loss of motor/sensory function, and blood transfusion were similar between robot systems. CONCLUSION: This is the first comparative analyses of screw accuracy, robot time/screw, robot abandonment, and radiation exposure between the Mazor X and Renaissance systems. There are substantial improvements in the X robot, particularly in the perioperative planning processes, which likely contribute to the X's superiority in S2AI screw accuracy by nearly 8-fold and robot reliability by nearly 10-fold.

2.
Cureus ; 13(6): e15939, 2021 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-34211815

RESUMO

Introduction There has been a surge in robot utilization in spine surgery over the past five years with the rapid development of new spine robotic platforms. This study aimed to compare a new robotic spine platform from Fusion RoboticsTM (Fusion Robotics, Helena, MT) with the widely used Mazor-XTM Stealth Edition robotic platform (Medtronic, Dublin, Ireland) in terms of workflow and lumbar pedicle screw placement accuracy. Methods A cadaver lab was conducted, which included four procedures with single-level lumbar pedicle screw placement using the Fusion RoboticsTM system. These four procedures were compared to four propensity-score matched cases with single-level lumbar pedicle screw placement using the Mazor-XTM Stealth Edition. A single surgeon performed all surgeries. The cases were matched in terms of demographics (age, sex, race, BMI) and comorbidities (Charlson Comorbidity Index score). The primary outcome measure was the operative workflow efficiency (duration as measured with a stopwatch by an independent observer). The secondary outcome measures were pedicle screw accuracy and accuracy to plan. Results After propensity-score matching, there were four cases in each group with no significant between-group differences in terms of sex, race, BMI, or surgical levels; however, there were significant differences in terms of age (p=0.01) and comorbidities (p<0.001). The workflow efficiency measurement showed that the Fusion RoboticsTM platform had a significantly shorter duration in terms of the system set-up time, planning to in-position time, and total procedure time (p<0.05). However, there was no significant difference between the robotic platforms in terms of creating a sterile barrier, scanning and importing images, creating a plan, screw placement, screw accuracy, and screw accuracy to plan. Conclusion Based on our findings, the Fusion RoboticsTM platform had a significantly shorter procedure workflow duration while maintaining the same accuracy as the most commonly used robotic platform (Mazor-XTM). This is the first study to directly compare different spine surgery robotic systems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA