1.
Int J Neurosci ; : 1-9, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38164709

RESUMO

AIM: Lambl's excrescences are mobile, thin, fibrinous connective tissue strands typically found on left-sided cardiac values. Migraine is positively associated with structural cardiac anomalies. However, it remains unclear whether Lambl's excrescences are associated with migraine. METHODS: Retrospective review of 182 inpatients with Lambl's excrescences confirmed by transesophageal echocardiogram in Chinese PLA General Hospital since January 2010. Among them, those with isolated Lambl's excrescences presented with migraine-like headache were included. We collected information on the demographics and clinical profiles of all participants, and performed follow-up visits. RESULTS: A total of 8 patients presented with migraine-like headache among 15 patients with isolated Lambl's excrescences. They included 2 men and 6 women, with an average age of 44.63 ± 12.24 years. Among these patients, 3 had visual aura, and 6 manifested infarct-like lesions on magnetic resonance imaging, of which 2 developed lesions after first visit. During follow-up, 4 patients suffering from intervention for Lambl's excrescences dramatically reduced headache recurrence compared to the other 4 patients only receiving migraine preventive medications. CONCLUSIONS: This study supports the hypothesis that microemboli from isolated Lambl's excrescences could cause migraine-like headache. And intervention for Lambl's excrescences may be crucial for preventing headache recurrence.


This study supports the hypothesis that microemboli from isolated Lambl's excrescences could cause migraine-like headache.The small sample size study fails to make management recommendations.

2.
Perfusion ; : 2676591241256089, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38783478

RESUMO

INTRODUCTION: Oxygenators for paediatric Extracorporeal Membrane Oxygenation (ECMO) are required to operate over a wide range of flow rates, in a patient group ranging from neonates through to fully grown adolescents. ECMO oxygenators typically have a manufacturer's stated maximum gas: blood flow rate (GBFR) ratio of 2:1, however, many patients require greater ratios than this for adequate CO2 removal. Mismatches in GBFR in theory could result in high gas phase pressures. These increased pressures in theory could cause the formation of gross gaseous microemboli (GME) placing the child at higher risk of neurological injury. METHODS: We evaluated 6 paediatric and 6 adult A.L.ONE™ ECMO oxygenators and assessed their gas phase pressures and GME release, in an ex vivo setting, in GBFR ratios up to greater than 2, across a range of gas flow (1L - 10 L/min) rates with a fraction of inspired oxygen (FiO2) content of 50% and 100%. RESULTS: There were no increases above 10 mmHg observed in gas phase pressures in GBFR >= 2:1 in either adult or paediatric oxygenators. Laboratory examination of GME activity demonstrated a small increase in post-membrane GME release over the study period. GME release was unaffected by FiO2 setting or gas flow rate, with a maximum volume of < 6 µL in both paediatric and adult oxygenators. CONCLUSIONS: In an ex vivo setting, increasing GBFR above 2:1 in a paediatric oxygenator, and to a GBFR of 2:1 in an adult oxygenator did not significantly increase gas phase pressures, and no oxygenator membrane rupture was observed. There were no associations between gas flow rates and GME production.

3.
Perfusion ; : 2676591241236892, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38420972

RESUMO

OBJECTIVE: During cardiopulmonary bypass (CPB), gaseous microemboli (GME) that originate from the extracorporeal circuit are released into the arterial blood stream of the patient. Gaseous microemboli may contribute to adverse outcome after cardiac surgery with CPB. Possibly, air may be collected in the right atrium during induction of anesthesia and released during CPB start. The aim of this study was to assess if the GME load entering the venous line of the CPB circuit could be reduced by training of anesthesia personal in avoiding air introduction during administration of intravenous medication. METHODS: In 94 patients undergoing coronary artery bypass grafting with CPB, GME number and volume were measured intraoperatively with a bubble counter (BCC300). The quantity and the relationship between GME number and volume in the venous and arterial line were determined in 2 periods before and after education of the anesthesiologists and nurses. RESULTS: In the venous line no significant differences were observed between numbers and volumes of GME between groups. Comparing patients with low versus high GME load, showed significantly more patients from the intervention group in the low GME-load group, namely 29 versus 18. Administration of medication by anesthesia was confirmed as a clear cause of GME/air-introduction into the venous circulation. Scavenging properties of the CPB circuit including the oxygenator showed a 99.9% reduction of GME. CONCLUSIONS: A wide spread of GME generation during perfusion was present with no difference in generation of GME between groups. Lower GME load observed in patients (intervention group) and examples of air introduction during drug administration suggest that air introduced by anesthesia contributes to the GME load during CPB. Scavenging properties of the CPB circuit contribute very much to patient safety regarding reduction of venous air. Awareness and education create the possibilities for further reduction of GME during cardiopulmonary bypass.

4.
Perfusion ; : 2676591241232824, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38323543

RESUMO

Brain injury is still a serious complication after cardiac surgery. Gaseous microemboli (GME) are known to contribute to both short and longer-term brain injury after cardiac surgery. Hypobaric and novel dual-chamber oxygenators use the physical behaviors and properties of gases to reduce GME. The aim of this review was to present the basic physics of the gases, the mechanism in which the hypobaric and dual-chamber oxygenators reduce GME, their technical performance, the preclinical studies, and future directions. The gas laws are reviewed as an aid to understanding the mechanisms of action of oxygenators. Hypobaric-type oxygenators employ a high oxygen, no nitrogen environment creating a steep concentration gradient of nitrogen out of the blood and into the oxygenator, reducing the risk of GMEs forming. Adequately powered clinical studies have never been carried out with a hypobaric or dual-chamber oxygenator. These are required before such technology can be recommended for widespread clinical use.

5.
Perfusion ; : 2676591241256532, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38768652

RESUMO

BACKGROUND: During cardiac surgery the use of a minimal extracorporeal circulation (MiECC) system may reduce the adverse effects for the patient. This is probably caused by reduced inflammation and hemodilution. For the use of a MiECC circuit, a venous bubble trap (VBT) is warranted for safety reasons. The aim of this study was to assess if an arterial filter with a small prime volume has the same (or better) air removal capacities as a VBT in a MiECC circuit and subsequentially may be used as an alternative. METHODS: In an in vitro study, air removal properties were compared between the arterial filter and three VBT's on the market, VBT160 (Getinge), VBT 8 (LivaNova and VARD (Medtronic). In a MiECC circuit, the filter devices were placed in a venous position and challenged with massive and micro air. Gaseous microemboli (GME) were measured with a bubble counter proximal and distal of the VBT device. RESULTS: More than 99.9 % of the air was removed after a bolus air challenge by all VBT's. Both the VARD and the AF100 showed better GME removal properties (not significant for the AF100) compared to the other devices. All filters showed GME generation after a challenge with massive air. Compared to the other filters, only the VARD showed no passing of larger bubbles when a volume of 50 mL of air was present in the filter. CONCLUSIONS: The AF100 seems to be a safe and low prime alternative for use in a MiECC system as a venous air trap. A word of caution, placement of the AF100 arterial filter in the venous line is off label use.

6.
J Stroke Cerebrovasc Dis ; 33(9): 107849, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38972617

RESUMO

OBJECTIVES: Cerebral microemboli can be detected by transcranial Doppler monitoring (TCDM) and may elucidate stroke etiology, the effect of preventive therapy, and the risk of stroke recurrence. Microemboli detection is usually performed for up to 60 minutes, but due to temporal variability, microembolization may be missed if the monitoring time is too short. We aimed to assess the time course of microembolization in acute ischemic stroke and explore the utility of prolonged and repeated microemboli detection. MATERIALS AND METHODS: Patients with suspected ischemic stroke and symptom onset within 24 hours were examined with bilateral, stationary TCDM for one hour followed by unilateral, ambulatory TCDM for two hours. Unilateral TCDM was repeated for the following two days and after three months. RESULTS: We included 47 patients, of which 41 had ischemic stroke, five had transient ischemic attack, and one had amaurosis fugax. Microemboli were detected in 60 % of patients. The occurrence was highest within 24 hours after onset and significantly lower at three months. Prolonged and repeated microemboli detection yielded only one additional microemboli-positive patient. Hence, patients who initially were microemboli negative tended to remain negative. We could not demonstrate an association between microemboli occurrence and clinical outcome or stroke recurrence. CONCLUSIONS: Microembolic signals are frequent within 24 hours after ischemic stroke onset, but prolonged and repeated microemboli detection did not increase the yield of MES positive patients. CLINICAL TRIAL REGISTRATION-URL: http://www. CLINICALTRIALS: gov. Unique identifier: NCT03543319.


Assuntos
Embolia Intracraniana , AVC Isquêmico , Valor Preditivo dos Testes , Ultrassonografia Doppler Transcraniana , Humanos , Masculino , Feminino , Idoso , AVC Isquêmico/etiologia , AVC Isquêmico/terapia , AVC Isquêmico/diagnóstico , AVC Isquêmico/diagnóstico por imagem , Fatores de Tempo , Pessoa de Meia-Idade , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/etiologia , Embolia Intracraniana/diagnóstico , Idoso de 80 Anos ou mais , Noruega/epidemiologia , Estudos Prospectivos , Fatores de Risco , Recidiva , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/diagnóstico por imagem , Ataque Isquêmico Transitório/terapia
7.
Artif Organs ; 47(10): 1663-1671, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37103478

RESUMO

BACKGROUND: The left ventricular assist device (LVAD) is a mechanical circulatory support device for patients with severe heart failure. Microbubbles caused by cavitation in the LVAD can potentially lead to physiological and pump-related complications. The aim of this study is to characterize the vibrational patterns in the LVAD during cavitation. METHODS: The LVAD was integrated into an in vitro circuit and mounted with a high-frequency accelerometer. Accelerometry signals were acquired with different relative pump inlet pressures ranging from baseline (+20 mmHg) to -600 mmHg in order to induce cavitation. Microbubbles were monitored with dedicated sensors at the pump inlet and outlet to quantify the degree of cavitation. Acceleration signals were analyzed in the frequency domain to identify changes in the frequency patterns when cavitation occurred. RESULTS: Significant cavitation occurred at the low inlet pressure (-600 mmHg) and was detected in the frequency range between 1800 and 9000 Hz. Minor degrees of cavitation at higher inlet pressures (-300 to -500 mmHg) were detected in the frequency range between 500-700, 1600-1700 Hz, and around 12 000 Hz. The signal power of the dominating frequency ranges was statistically significantly different from baseline signals. CONCLUSION: Vibrational measurements in the LVAD can be used to detect cavitation. A significant degree of cavitation could be detected in a wide frequency range, while minor cavitation activity could only be detected in more narrow frequency ranges. Continuous vibrational LVAD monitoring can potentially be used to detect cavitation and minimize the damaging effect associated with cavitation.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Pressão , Insuficiência Cardíaca/cirurgia
8.
Perfusion ; 38(5): 993-1001, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-35603520

RESUMO

INTRODUCTION: Varying the insertion depth of the aortic cannula during cardiopulmonary bypass (CPB) has been investigated as a strategy to mitigate cerebral emboli, yet its effectiveness associated with CPB flow is not fully understood. We compared different arterial cannula insertion depths and pump flow influencing air microemboli entering the aortic arch branch arteries (AABA). METHODS: A computational approach used a patient-specific aorta model to evaluate four cannula locations at (1) proximal arch, (2) mid arch, (3) distal arch, and (4) descending aorta. We injected 0.1 mm microemboli (N=720) at 2 and 5 L/min and assessed the embolic load and the particle averaged transit times ( entering the AABA. RESULTS: Location 4 had the lowest embolic load (2 L/min: N= 63) and (5 L/min: N= 54) compared to locations 1 to 3 in the range of (N= 118 to 116 at 2 L/min:) and (N= 92 to 146 at 5 L/min). There was no significant difference between 2 L/min and 5 L/min (p = 0.31), despite 5 L/min attaining a lower mean (±standard deviation) than 2 L/min (38.0±23.4 vs 44.5±21.1), respectively. Progressing from location 1 to 4, increased 3.11s -7.40 s at 2 L/min and 1.81s -4.18s at 5 L/min. CONCLUSION: It was demonstrated that the elongated cannula insertion length resulted in lower embolic loads, particularly at a higher flow rate. The numerical results suggest that CPB management could combine active flow variation with improving cannula performance and provide a foundation for a future experimental and clinical investigation to reduce surgical cerebral air microemboli.


Assuntos
Ponte Cardiopulmonar , Embolia Aérea , Humanos , Ponte Cardiopulmonar/métodos , Aorta , Cateterismo
9.
Perfusion ; 38(4): 734-739, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35348392

RESUMO

INTRODUCTION: The novel Capiox NX19 adult oxygenator is, compared to its predecessors, improved with enhanced air removal technology, a polymer heat exchanger and smaller, innovative hollow fibers resulting in a surface area reduction and a lower priming volume. The aim of this study was to evaluate the NX19 oxygenator performance in a clinical setting. METHODS: A prospective multicenter study was performed involving three large European university hospitals. The Capiox NX19 (n = 150) performance was assessed during adult cardiopulmonary bypass and involved gaseous microemboli handling and gas transfer efficiency. The heat exchanger performance was evaluated separately in vitro. RESULTS: The heat exchanger performance factors were 0.80 ± 0.03 and 0.58 ± 0.04 at pump flow rates of 3 L/min and 6 L/min, respectively. After priming, residual post-oxygenator gaseous microemboli count and volume were decreased by 91% and 93.7%, respectively. The gas compartment pressure was 6.0 ± 2.5 mmHg, while the O2 transfer was 69 ± 30 mL/min/m2 and the CO2 transfer 73 ± 34 mL/min/m2. The O2 gradient was 44 ± 19 mmHg/LPM and the O2 diffusing capacity 0.38 ± 0.14 mL/min/mmHg. The shunt fraction was 0.19 ± 0.13, whereas oxygenator resistance and shear stress were 10.5 ± 3.7 mmHg/LPM and 5.1 ± 3.1 dyn/cm2, respectively. CONCLUSION: This multicenter study displayed good clinical safety and performance of the NX19 oxygenator.


Assuntos
Oxigenação por Membrana Extracorpórea , Oxigenadores de Membrana , Adulto , Humanos , Estudos Prospectivos , Desenho de Equipamento , Ponte Cardiopulmonar , Gases
10.
Int J Mol Sci ; 24(15)2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37569332

RESUMO

Circulating tumor cells (CTCs) and/or circulating tumor microemboli (CTM) from non-small cell lung cancer (NSCLC) patients may be a non-invasive tool for prognosis, acting as liquid biopsy. CTCs interact with platelets through the transforming growth factor-ß/transforming growth factor-ß receptor type 1 (TGF-ß/TGFßRI) forming clusters. CTCs also may express the Cluster of Differentiation 47 (CD47) protein, responsible for the inhibition of phagocytosis, the "don't eat me" signal to macrophages. OBJECTIVES: To isolate, quantify and analyze CTCs/CTMs from metastatic NSCLC patients, identify TGFßRI/CD47 expression in CTCs/CTMs, and correlate with progression-free survival (PFS). METHODS: Blood (10 mL) was collected at two time-points: T1 (before the beginning of any line of treatment; T2 (60 days after initial collection). CTCs were isolated using ISET®. Immunocytochemistry was conducted to evaluate TGFßRI/CD47 expression. RESULTS: 45 patients were evaluated. CTCs were observed in 82.2% of patients at T1 (median: 1 CTC/mL; range: 0.33-11.33 CTCs/mL) and 94.5% at T2 (median: 1.33 CTC/mL; 0.33-9.67). CTMs were observed in 24.5% of patients and significantly associated with poor PFS (10 months vs. 17 months for those without clusters; p = 0.05) and disease progression (p = 0.017). CTMs CD47+ resulted in poor PFS (p = 0.041). TGFßRI expression in CTCs/CTMs was not associated with PFS. CONCLUSION: In this study, we observed that CTC/CTM from NSCLC patients express the immune evasion markers TGFßRI/CD47. The presence of CTMs CD47+ is associated with poor PFS. This was the first study to investigate CD47 expression in CTCs/CTM of patients with NSCLC and its association with poor PFS.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Células Neoplásicas Circulantes , Humanos , Carcinoma Pulmonar de Células não Pequenas/patologia , Células Neoplásicas Circulantes/patologia , Antígeno CD47 , Neoplasias Pulmonares/metabolismo , Biomarcadores , Receptor do Fator de Crescimento Transformador beta Tipo I , Fatores de Crescimento Transformadores , Biomarcadores Tumorais/metabolismo
11.
J Clin Lab Anal ; 36(7): e24524, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35657145

RESUMO

BACKGROUND: This study compared whole blood dilution versus density gradient centrifugation for pre-processing blood samples prior to circulating tumor cell (CTC) capture on the efficiency of CTC separation by size-based isolation. MATERIALS AND METHODS: Whole blood from a healthy volunteer spiked with SKBR3 cells was used to optimize the whole blood dilution protocol for sample volume, dilution ratio, and paraformaldehyde (PFA) concentration. Whole blood from healthy volunteers spiked with SKBR3, A549, or PC3 cells, and whole blood from patients with advanced gastric, esophageal, or liver cancer, was used to compare pre-processing by the optimal whole blood dilution protocol with density-gradient centrifugation. All statistical evaluations were performed using Student t test of the Statistical Package for Social Sciences (SPSS version 17.0). RESULTS: In blood samples from healthy volunteers, spiked SKBR3 cell recovery rates were highest in 5 ml of whole blood, diluted with 2.5 ml buffer, and fixed with 0.2% PFA, and spiked SKBR3, A549, and PC3 cell recovery rates from 5 ml whole blood were significantly greater when using the optimized whole blood dilution protocol (87.67% ± 1.76%, 79.50% ± 0.50% and 71.83% ± 1.04%, respectively) compared to density-gradient centrifugation (46.83 ± 1.76%, 37.00 ± 1.50% and 41.00 ± 1.50%, respectively).


Assuntos
Células Neoplásicas Circulantes , Linhagem Celular Tumoral , Separação Celular/métodos , Humanos , Células Neoplásicas Circulantes/patologia
12.
Perfusion ; 37(3): 242-248, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33567967

RESUMO

INTRODUCTION: Extracorporeal life support (ECLS) patients are at risk for complications caused by gaseous microemboli (GME). GMEs can cause hypoxia, inflammation, coagulation, and end-organ damage. The objective of this in vitro study was to assess dynamics of GME formation during circulation of whole blood or a glycerol blood surrogate. We hypothesized that there is no difference in GME counts and sizes between whole blood and the glycerol blood surrogate and that the membrane lung reduces GME counts over time. METHODS: A circulation platform was developed using the Cardiohelp ECLS system to run either donor blood or glycerol solution. We conducted 10 repetitions consisting of three phases of ultrasound GME detection using the EDAC™ Quantifier (Luna Innovations, Charlottesville, VA, USA) for each group. Phases were 3-minute recordings at the initiation of 2 L/min flow (Phase 1), post-injection of a GME suspension (Phase 2), and 10 minutes after injection (Phase 3). The number and size of GME pre- and post-ML were recorded separately and binned based on diameter ranges. RESULTS: In Phase 1, GME count in blood was higher than in glycerol. In Phase 2, there was a large increase in GME counts; however, most GME were reduced post-membrane in both groups. In Phase 3, there was a significant decrease in GME counts compared to Phase 2. GME > 100 µm in glycerol decreased post membrane. CONCLUSIONS: We demonstrated GME formation and decay dynamics during in vitro circulation in an ECLS system with blood and glycerol. GME counts were higher in blood, likely due to varying rheological properties. There were decreases in GME levels post membrane in both groups after GME injection, with the membrane lung effectively trapping the GME, and additional reduction 10 minutes after GME injection.


Assuntos
Embolia Aérea , Circulação Extracorpórea , Oxigenação por Membrana Extracorpórea , Ponte Cardiopulmonar , Embolia Aérea/etiologia , Desenho de Equipamento , Oxigenação por Membrana Extracorpórea/efeitos adversos , Gases , Glicerol , Humanos , Sistemas de Manutenção da Vida
13.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 53(4): 711-715, 2022 Jul.
Artigo em Chinês | MEDLINE | ID: mdl-35871746

RESUMO

A 77-year-old man was admitted at our hospital due to "generalized increase in the number of masses and enlargement of the masses observed for one month". Combined assessment of the imaging (computed tomography and magnetic resonance imaging) findings and results of lung centesis biopsy and liquid biopsy suggest that the patient had small cell lung cancer of the left upper lobe, with right hilar, mediastinal, bilateral axillary, abdominal and retroperitoneal lymph node metastases, as well as widespread subcutaneous soft tissue, liver, bilateral adrenal, bilateral kidneys and multiple brain metastases (extensive stage). In order to obtain an evaluation of the development of the disease as soon as possible, the circulating tumor cells (CTCs) and circulating tumor microemboli (CTM) in 6 mL peripheral blood were examined by subtraction enrichment-immunostaining fluorescence in situ hybridization (SE-iFISH) technology. A total of 919 epithelial cell adhesion molecule (EpCAM)-positive CTCs and 61 EpCAM-positive CTM were identified. Among them, there were 14 haploid CTCs (1.52%), 788 diploid CTCs (85.75%), 44 triploid CTCs (4.79%), 70 tetraploid CTCs (7.62%) and 3 pentaploid or higher-fold polyploid CTCs (0.33%). Herein, we reported a rare case with extremely high accounts of CTCs and CTM and positive findings for tumor markers, which was identified for the first time. The examination of CTCs by SE-iFISH contributed to the diagnosis, prognosis and treatment evaluation of cancer and facilitated the formulation of precise and individualized therapeutic regime.


Assuntos
Neoplasias Pulmonares , Células Neoplásicas Circulantes , Carcinoma de Pequenas Células do Pulmão , Idoso , Biomarcadores Tumorais/metabolismo , Molécula de Adesão da Célula Epitelial/metabolismo , Humanos , Hibridização in Situ Fluorescente , Neoplasias Pulmonares/patologia , Masculino , Células Neoplásicas Circulantes/metabolismo , Células Neoplásicas Circulantes/patologia
14.
Europace ; 23(1): 139-146, 2021 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-33111141

RESUMO

AIMS: Irreversible electroporation (IRE) ablation is a non-thermal ablation method based on the application of direct current between a multi-electrode catheter and skin electrode. The delivery of current through blood leads to electrolysis. Some studies suggest that gaseous (micro)emboli might be associated with myocardial damage and/or (a)symptomatic cerebral ischaemic events. The aim of this study was to compare the amount of gas generated during IRE ablation and during radiofrequency (RF) ablation. METHODS AND RESULTS: In six 60-75 kg pigs, an extracorporeal femoral shunt was outfitted with a bubble-counter to detect the size and total volume of gas bubbles. Anodal and cathodal 200 J IRE applications were delivered in the left atrium (LA) using a 14-electrode circular catheter. The 30 and 60 s 40 W RF point-by-point ablations were performed. Using transoesophageal echocardiography (TOE), gas formation was visualized. Average gas volumes were 0.6 ± 0.6 and 56.9 ± 19.1 µL (P < 0.01) for each anodal and cathodal IRE application, respectively. Also, qualitative TOE imaging showed significantly less LA bubble contrast with anodal than with cathodal applications. Radiofrequency ablations produced 1.7 ± 2.9 and 6.7 ± 7.4 µL of gas, for 30 and 60 s ablation time, respectively. CONCLUSION: Anodal IRE applications result in significantly less gas formation than both cathodal IRE applications and RF applications. This finding is supported by TOE observations.


Assuntos
Ablação por Cateter , Animais , Ablação por Cateter/efeitos adversos , Catéteres , Eletroporação , Gases , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Suínos
15.
J Cutan Pathol ; 48(9): 1173-1177, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33934378

RESUMO

Occlusive nonvasculitic vasculopathy is a process characterized clinically by retiform purpura and potential ulceration and necrosis of affected areas, secondary to blockage of small vessels without associated inflammatory vasculitis. Intravascular injection of foreign material is known to cause distal ischemia and necrosis due to thrombosis, local vasoconstriction, or microemboli formation. A 27-year-old male presented with retiform purpura and worsening distal fingertip necrosis of the right upper extremity accompanied by suspicious intravascular polarizable foreign material identified on skin, muscle, and vascular biopsies. We report a case that highlights concerning complications and dermatopathologic findings of intravascular injection of oral opioid tablets.


Assuntos
Analgésicos Opioides/efeitos adversos , Embolia/diagnóstico , Dermatopatias Vasculares/patologia , Vasculite/patologia , Adulto , Analgésicos Opioides/administração & dosagem , Biópsia , Embolia/etiologia , Fasciotomia/métodos , Evolução Fatal , Dedos/patologia , Corpos Estranhos/diagnóstico , Reação a Corpo Estranho/diagnóstico , Reação a Corpo Estranho/cirurgia , Humanos , Injeções Intravenosas , Masculino , Necrose/diagnóstico , Necrose/etiologia , Cooperação do Paciente/psicologia , Púrpura/diagnóstico , Púrpura/etiologia , Pele/patologia , Transtornos Relacionados ao Uso de Substâncias/complicações , Transtornos Relacionados ao Uso de Substâncias/patologia , Comprimidos/administração & dosagem , Vasculite/cirurgia
16.
World J Surg Oncol ; 19(1): 156, 2021 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-34034739

RESUMO

BACKGROUND: Renal cell carcinoma (RCC) is a common malignant tumour of the genitourinary system. We aimed to analyse the potential value of metastasis-related biomarkers, circulating tumour cells (CTCs) and the proliferative marker Ki-67 in the diagnosis of RCC. METHODS: Data from 24 laparoscopic radical nephrectomies (RNs) and 17 laparoscopic partial nephrectomies (PNs) were collected in 2018. The numbers and positive rates of CTCs and circulating tumour microemboli (CTM) in the peripheral blood were obtained at three different time points: just before surgery, immediately after surgery and 1 week after surgery. Ki-67 protein expression was evaluated in the RCC tissue by immunohistochemistry. RESULTS: Except for the statistically significant association between the preoperative CTC counts and tumour size, no association between the number and positive rate of perioperative CTCs and clinicopathological features was found. The CTC counts gradually decreased during the perioperative period, and at 1 week after surgery, they were significantly lower than those before surgery. High Ki-67 expression was significantly positively correlated with preoperative CTC counts. In addition, Ki-67 expression was higher in the high CTC group (≥ 5 CTCs). CONCLUSION: Our results suggest that surgical nephrectomy is associated with a decrease in CTC counts in RCC patients. CTCs can act as a potential biomarker for the diagnosis and prognosis of RCC. A careful and sufficient long-term follow-up is needed for patients with high preoperative CTC counts.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Células Neoplásicas Circulantes , Biomarcadores Tumorais , Carcinoma de Células Renais/cirurgia , Humanos , Antígeno Ki-67 , Neoplasias Renais/cirurgia , Prognóstico
17.
J Electrocardiol ; 68: 135-140, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34419649

RESUMO

BACKGROUND: Advanced interatrial block (IAB) is present in 10% of subjects ≥75 years and is associated with the risk of clinical events. METHODS AND RESULTS: Prospective multicenter study that will include subjects ≥75 years without exclusion criteria (indication for anticoagulation, cardiac devices, severe valve disease, systolic dysfunction, moderate or severe cognitive impairment, poor echocardiographic window, non-sinus rhythm or partial IAB, stroke, and life expectancy <2 years). A total of 356 subjects, 178 patients with advanced IAB (exposed) and 178 matched individuals with normal P-wave (non-exposed) will be included. Electrocardiogram and advanced transthoracic echocardiography will be performed. Two substudies will include magnetic resonance imaging: cardiac (86 subjects, 43 exposed, and 43 non-exposed) and brain (86 subjects, 43 exposed, and 43 non-exposed). The follow-up will be 2 years. Our main objective is to determine the association of advanced IAB, P-wave duration, and atrial imaging parameters (I] atrial global longitudinal strain, II] maximal left atrial volume index, III] left atrial ejection fraction, IV] left atrial fibrosis - % total left atrial area V] inter- and intra-atrial asynchrony/dyssynchrony) with clinical events (atrial fibrillation, stroke, cognitive impairment, and mortality). The secondary objective is to assess the association of the P-wave duration with atrial imaging parameters and of both with cerebral microemboli in magnetic resonance imaging. CONCLUSION: Our study will provide data regarding the association of advanced IAB, P-wave duration, and atrial imaging parameters with clinical events. We will also assess the association P-wave duration-atrial imaging parameters-cerebral microemboli.


Assuntos
Fibrilação Atrial , Bloqueio Interatrial , Fibrilação Atrial/diagnóstico por imagem , Eletrocardiografia , Átrios do Coração/diagnóstico por imagem , Humanos , Bloqueio Interatrial/diagnóstico por imagem , Estudos Prospectivos
18.
J Extra Corpor Technol ; 53(1): 75-79, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33814610

RESUMO

The current practice of cardiopulmonary bypass (CPB) requires a preoperative priming of the circuit that is frequently performed with crystalloid solutions. Crystalloid priming avoids massive embolism but is unable to eliminate all microbubbles contained in the circuit. In addition, it causes a sudden hemodilution which is correlated with transfusion requirements and an increased risk of cognitive impairment. Several repriming techniques using autologous blood, collectively termed retrograde autologous priming (RAP), have been demonstrated to reduce the hemodilutional impact of CPB. However, the current heterogeneity in the practice of RAP limits its evidence and benefits. Here, we describe hematic antegrade repriming as an easy and reliable method that could be applied with any circuit in the market to decrease transfusion requirements, emboli, and inflammatory responses, reducing costs and the impact of CPB on postoperative recovery.


Assuntos
Transfusão de Sangue Autóloga , Ponte Cardiopulmonar , Transfusão de Sangue , Soluções Cristaloides , Hemodiluição , Humanos
19.
BMC Neurol ; 20(1): 94, 2020 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-32171270

RESUMO

BACKGROUND: Infectious basilar artery (BA) aneurysm has been occasionally reported to be generated from meningitis following transcranial operation. However, infectious BA aneurysm formed by intracranial infection after endoscopic endonasal operation has never been reported. CASE PRESENTATION: A 53-year-old man who was diagnosed with suprasellar region meningioma received tumor removal via endoscopic endonasal approach. After operation he developed cerebrospinal fluid (CSF) leak and intracranial infection. The patient ultimately recovered from infection after anti-infective therapy, but a large fusiform BA aneurysm was still formed and ruptured in a short time. Interventional and surgical measures were impossible due to the complicated shape and location of aneurysm and state of his endangerment, therefore, conservative anti-infective therapy was adopted as the only feasible method. Unfortunately, the aneurysm did not disappear and the patient finally died from repeating subarachnoid hemorrhage (SAH). CONCLUSION: Though extremely rare, it was emphasized that infectious aneurysm can be formed at any stage after transnasal surgery, even when the meningitis is cured. Because of the treatment difficulty and poor prognosis, it was recommended that thorough examination should be timely performed for suspicious patient to make correct diagnosis and avoid fatal SAH.


Assuntos
Aneurisma Roto/etiologia , Aneurisma Intracraniano/etiologia , Meningite/complicações , Cirurgia Endoscópica por Orifício Natural/efeitos adversos , Complicações Pós-Operatórias/etiologia , Hemorragia Subaracnóidea/etiologia , Antibacterianos/uso terapêutico , Artéria Basilar , Endoscopia , Evolução Fatal , Humanos , Masculino , Neoplasias Meníngeas/cirurgia , Meningioma/cirurgia , Meningite/tratamento farmacológico , Pessoa de Meia-Idade , Neoplasias da Base do Crânio/cirurgia
20.
Artif Organs ; 44(1): 28-39, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30512218

RESUMO

The purpose of this study was to evaluate the hemodynamic properties and microemboli capture associated with different vacuum-assisted venous drainage (VAVD) vacuum levels and venous reservoir levels in a neonatal cardiopulmonary bypass circuit. Trials were conducted in 2 parallel circuits to compare the performance of Capiox Baby RX05 oxygenator with separate AF02 arterial filter to Capiox FX05 oxygenator with integrated arterial filter. Arterial cannula flow rate to the patient was held at 500 mL/min and temperature maintained at 32°C, while VAVD vacuum levels (0 mm Hg, -15 mm Hg, -30 mm Hg, -45 mm Hg, -60 mm Hg) and venous reservoir levels (50 mL, 200 mL) were evaluated in both oxygenators. Hemodynamic parameters measuring flow, pressure, and total hemodynamic energy were made in real time using a custom-made data acquisition system and Labview software. Nearly 10 cc bolus of air was injected into the venous line and gaseous microemboli detected using an Emboli Detection and Classification Quantifier. Diverted blood flow via the arterial filter's purge line and mean pressures increased with increasing VAVD levels (P < 0.01). Mean pressures were lower with lower venous reservoir levels and were greater in RX05 groups compared to FX05 (P < 0.01). Microemboli detected at the preoxygenator site increased with higher VAVD vacuum levels and lower venous reservoir levels (P < 0.01). The amount of microemboli captured by the FX05 oxygenator with integrated arterial filter was greater than by the RX05 oxygenator alone, although both oxygenators were able to clear microemboli before reaching the pseudo-patient.


Assuntos
Ponte Cardiopulmonar/instrumentação , Hemodinâmica , Oxigenadores de Membrana , Drenagem/instrumentação , Desenho de Equipamento , Humanos , Recém-Nascido , Modelos Cardiovasculares , Vácuo , Dispositivos de Acesso Vascular