Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Arthroplasty ; 39(6): 1518-1523, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38103805

RESUMO

BACKGROUND: Mid-level constraint polyethylene designs provide additional stability in total knee arthroplasty (TKA). The purposes of this study were to (1) compare the survivorship and reason for revision between mid-level inserts and posterior-stabilized (PS) used in primary TKA and (2) evaluate the biomechanical constraint characteristics of mid-level inserts. METHODS: We reviewed all cases of primary TKA performed at our institution from 2016 to 2019 using either PS or mid-level constrained inserts from 1 of 6 manufacturers. Data elements included patient demographics, implants, reasons for revision, and whether a manipulation under anesthesia was performed. We performed finite element analyses to quantify the varus/valgus and axial-rotation constraint of each mid-level constrained insert. A one-to-one propensity score matching was conducted between the patients with mid-level and PS inserts to match for variables, which yielded 2 cohorts of 3,479 patients. RESULTS: For 9,163 PS and 3,511 mid-level TKAs, survivorship free from all-cause revision was estimated up to 5 years and was lower for mid-level than PS inserts (92.7 versus 94.1%, respectively, P = .004). When comparing each company's mid-level insert to the same manufacturer's PS insert, we found no differences in all-cause revision rates (P ≥ .91) or revisions for mechanical problems (P ≥ .97). Using propensity score matching between mid-level and PS groups, no significant differences were found in rates of manipulation under anesthesia (P = .72), all-cause revision (P = .12), revision for aseptic loosening (P = .07), and revision for instability (P = .45). Finite element modeling demonstrated a range in varus/valgus constraint from ±1.1 to >5°, and a range in axial-rotation constraint from ±1.5 to ±11.5° among mid-level inserts. CONCLUSIONS: Despite wide biomechanical variations in varus/valgus and axial-rotation constraint, we found minimal differences in early survivorship rates between PS and mid-level constrained knees.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Polietileno , Desenho de Prótese , Falha de Prótese , Reoperação , Humanos , Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/métodos , Masculino , Idoso , Feminino , Reoperação/estatística & dados numéricos , Fenômenos Biomecânicos , Pessoa de Meia-Idade , Análise de Elementos Finitos , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiopatologia , Estudos Retrospectivos , Idoso de 80 Anos ou mais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA