Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
1.
Proc Natl Acad Sci U S A ; 120(11): e2219948120, 2023 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-36897967

RESUMO

A method for low-distortion (low-dissipation, low-dispersion) information propagation in swarm-type networks with suppression of high-frequency noise is presented. Information propagation in current neighbor-based networks, where each agent seeks to achieve a consensus with its neighbors, is diffusion-like, dissipative, and dispersive and does not reflect the wave-like (superfluidic) behavior seen in nature. However, pure wave-like neighbor-based networks have two challenges: i) It requires additional communication for sharing information about time derivatives and ii) it can lead to information decoherence through noise at high frequencies. The main contribution of this work is to show that delayed self-reinforcement (DSR) by the agents using prior information (e.g., using short-term memory) can lead to the wave-like information propagation at low-frequencies as seen in nature without the need for additional information sharing between the agents. Moreover, it is shown that the DSR can be designed to enable suppression of high-frequency noise transmission while limiting the dissipation and dispersion of (lower-frequency) information content leading to similar (cohesive) behavior of agents. In addition to explaining noise-suppressed wave-like information transfer in natural systems, the result impacts the design of noise-suppressing cohesive algorithms for engineered networks.

2.
NMR Biomed ; 37(6): e5129, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38494431

RESUMO

Proton magnetic resonance spectroscopy (1H-MRS) is increasingly used for clinical brain tumour diagnosis, but suffers from limited spectral quality. This retrospective and comparative study aims at improving paediatric brain tumour classification by performing noise suppression on clinical 1H-MRS. Eighty-three/forty-two children with either an ependymoma (ages 4.6 ± 5.3/9.3 ± 5.4), a medulloblastoma (ages 6.9 ± 3.5/6.5 ± 4.4), or a pilocytic astrocytoma (8.0 ± 3.6/6.3 ± 5.0), recruited from four centres across England, were scanned with 1.5T/3T short-echo-time point-resolved spectroscopy. The acquired raw 1H-MRS was quantified by using Totally Automatic Robust Quantitation in NMR (TARQUIN), assessed by experienced spectroscopists, and processed with adaptive wavelet noise suppression (AWNS). Metabolite concentrations were extracted as features, selected based on multiclass receiver operating characteristics, and finally used for identifying brain tumour types with supervised machine learning. The minority class was oversampled through the synthetic minority oversampling technique for comparison purposes. Post-noise-suppression 1H-MRS showed significantly elevated signal-to-noise ratios (P < .05, Wilcoxon signed-rank test), stable full width at half-maximum (P > .05, Wilcoxon signed-rank test), and significantly higher classification accuracy (P < .05, Wilcoxon signed-rank test). Specifically, the cross-validated overall and balanced classification accuracies can be improved from 81% to 88% overall and 76% to 86% balanced for the 1.5T cohort, whilst for the 3T cohort they can be improved from 62% to 76% overall and 46% to 56%, by applying Naïve Bayes on the oversampled 1H-MRS. The study shows that fitting-based signal-to-noise ratios of clinical 1H-MRS can be significantly improved by using AWNS with insignificantly altered line width, and the post-noise-suppression 1H-MRS may have better diagnostic performance for paediatric brain tumours.


Assuntos
Neoplasias Encefálicas , Espectroscopia de Prótons por Ressonância Magnética , Razão Sinal-Ruído , Humanos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/metabolismo , Criança , Espectroscopia de Prótons por Ressonância Magnética/métodos , Feminino , Masculino , Pré-Escolar , Adolescente , Estudos Retrospectivos , Lactente
3.
Sensors (Basel) ; 24(4)2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38400245

RESUMO

Wearable devices have been widely used for the home monitoring of physical activities and healthcare conditions, among which ambulatory electrocardiogram (ECG) stands out for the diagnostic cardiovascular information it contains. Continuous and unobtrusive sensing often requires the integration of wearable sensors to existing devices such as watches, armband, headphones, etc.; nonetheless, it is difficult to detect high-quality ECG due to the nature of low signal amplitude at these areas. In this paper, a high-performance system with multi-channel signal superposition for weak ECG real-time detection is proposed. Firstly, theoretical analysis and simulation is performed to demonstrate the effectiveness of this system design. The detection system, including electrode array, acquisition board, and the application (APP), is then developed and the electrical characteristics are measured. A common mode rejection ratio (CMRR) of up to 100 dB and input inferred voltage noise below 1 µV are realized. Finally, the technique is implemented in form of ear-worn and armband devices, achieving an SNR over 20 dB. Results are also compared with the simultaneous recording of standard lead I ECG. The correlation between the heart rates derived from experimental and standard signals is higher than 0.99, showing the feasibility of the proposed technique.


Assuntos
Processamento de Sinais Assistido por Computador , Dispositivos Eletrônicos Vestíveis , Eletrocardiografia Ambulatorial , Eletrocardiografia , Coração
4.
Sensors (Basel) ; 24(5)2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38474916

RESUMO

Ferromagnetic debris in lubricating oil, serving as an important communication carrier, can effectively reflect the wear condition of mechanical equipment and predict the remaining useful life. In practice application, the detection signals collected by using inductive sensors contain not only debris signals but also noise terms, and weak debris features are prone to be distorted, which makes it a severe challenge to debris signature identification and quantitative estimation. In this paper, a debris signature extraction method established on segmentation entropy with an adaptive threshold was proposed, based on which five identification indicators were investigated to improve detection accuracy. The results of the simulations and oil experiment show that the proposed algorithm can effectively identify wear particles and preserve debris signatures.

5.
Sensors (Basel) ; 24(11)2024 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-38894224

RESUMO

A phasemeter as a readout system for the inter-satellite laser interferometer in a space-borne gravitational wave detector requires not only high accuracy but also insensitivity to amplitude fluctuations and a large fast-acquiring range. The traditional sinusoidal characteristic phase detector (SPD) phasemeter has the advantages of a simple structure and easy realization. However, the output of an SPD is coupled to the amplitude of the input signal and has only a limited phase-detection range due to the boundedness of the sinusoidal function. This leads to the performance deterioration of amplitude noise suppression, fast-acquiring range, and loop stability. To overcome the above shortcomings, we propose a phasemeter based on a tangent phase detector (TPD). The characteristics of the SPD and TPD phasemeters are theoretically analyzed, and a fixed-point simulation is further carried out for verification. The simulation results show that the TPD phasemeter tracks the phase information well and, at the same time, suppresses the amplitude fluctuation to the noise floor of 1 µrad/Hz1/2, which meets the requirements of GW detection. In addition, the maximum lockable step frequency of the TPD phasemeter is almost three times larger than the SPD phasemeter, indicating a greater fast-acquiring range.

6.
Sensors (Basel) ; 23(2)2023 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-36679829

RESUMO

Ultrasonic nondestructive testing (NDT) provides a valuable insight into the integrity of stainless steel structures, but the noise caused by the scattering of stainless steel microstructure often limits the effectiveness of inspection. This work presents a novel adaptive filtering approach to enhance the signal-to-noise ratio (SNR) of a measured ultrasonic signal from the inspection of a stainless steel component, enabling the detection of hidden flaws under strong noise. After the spectral modeling of the noisy ultrasonic NDT signal, the difference between the spectral characteristics of a flaw echo and that of grain noise is highlighted, and a reference spectrum model to estimate the frequency spectrum of the echo reflected by any possible flaw is developed. Then, the signal is segmented and the similarity between the spectra of data segments and the reference spectra is evaluated quantitatively by the spectral similarity index (SSI). Based on this index, an adaptive time-frequency filtering scheme is proposed. Each data segment is processed by the filtering to suppress the energy of noise. The processed data segments are recombined to generate the de-noised signal after multiplying weighting coefficients, which again is determined by the SSI. The performance of the proposed method for SNR enhancement is evaluated by both the simulated and experimental signal and the effectiveness has been successfully demonstrated.


Assuntos
Aço Inoxidável , Ultrassom , Razão Sinal-Ruído , Ruído , Grão Comestível
7.
Entropy (Basel) ; 25(9)2023 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-37761585

RESUMO

Continuous-variable quantum key distribution (CV-QKD) is a promising protocol that can be easily integrated with classical optical communication systems. However, in the case of quantum-classical co-transmissions, such as dense wavelength division multiplexing with classical channels and time division multiplexing with large-power classical signal, a quantum signal is more susceptible to crosstalk caused by a classical signal, leading to signal distortion and key distribution performance reduction. To address this issue, we propose a noise-suppression scheme based on carrier frequency switching (CFS) that can effectively mitigate the influence of large-power random noise on the weak coherent state. In this noise-suppression scheme, a minimum-value window of the channel's noise power spectrum is searched for and the transmission signal frequency spectrum shifts to the corresponding frequency to avoid large-power channel noise. A digital filter is also utilized to filter out most of the channel noise. Simulation results show that compared to the traditional fixed carrier frequency scheme, the proposed noise-suppression scheme can reduce the excess noise to 1.8%, and the secret key rate can be increased by 1.43 to 2.86 times at different distances. This noise-suppression scheme is expected to be applied in scenarios like quantum-classical co-transmission and multi-QKD co-transmission to provide noise-suppression solutions.

8.
Sensors (Basel) ; 22(10)2022 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-35632225

RESUMO

Terahertz lensless phase retrieval imaging is a promising technique for non-destructive inspection applications. In the conventional multiple-plane phase retrieval method, the convergence speed due to wave propagations and measures with equal interval distance is slow and leads to stagnation. To address this drawback, we propose a nonlinear unequal spaced measurement scheme in which the interval space between adjacent measurement planes is gradually increasing, it can significantly increase the diversity of the intensity with a smaller number of required images. Both the simulation and experimental results demonstrate that our method enables quantitative phase and amplitude imaging with a faster speed and better image quality, while also being computationally efficient and robust to noise.

9.
Sensors (Basel) ; 22(13)2022 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-35808419

RESUMO

Electrostatic suspended accelerometers (ESAs) are widely used in high accuracy acceleration measurement. However, there exist accumulated charges on the isolated mass which damage the accuracy and the stability of ESAs. In this paper, we propose to apply actuation voltage with a combined waveform to suppress the acceleration noise due to deposited charge. A model of the electrostatic force on the mass is established and the deviation voltage is found to be the dominant source of charge noise. Based on the analysis of disturbance electrostatic force under DC and AC signals, actuation combined with DC and AC voltage is designed and the disturbance force due to charge can be suppressed through adjustment towards the duty cycle of different compositions. Simulations and experiments are carried out and the results indicate that the disturbance due to charge can be suppressed up to 40%, which validates the efficiency of the scheme.

10.
Sensors (Basel) ; 22(20)2022 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-36298133

RESUMO

It is difficult for traditional signal-recognition methods to effectively classify and identify multiple emitter signals in a low SNR environment. This paper proposes a multi-emitter signal-feature-sorting and recognition method based on low-order cyclic statistics CWD time-frequency images and the YOLOv5 deep network model, which can quickly dissociate, label, and sort the multi-emitter signal features in the time-frequency domain under a low SNR environment. First, the denoised signal is extracted based on the low-order cyclic statistics of the typical modulation types of radiation source signals. Second, the time-frequency graph of multisource signals was obtained through CWD time-frequency analysis. The cyclic frequency was controlled to balance the noise suppression effect and operation time to achieve noise suppression of multisource signals at a low SNR. Finally, the YOLOv5s deep network model is used as a classifier to sort and identify the received signals from multiple radiation sources. The method proposed in this paper has high real-time performance. It can identify the radiation source signals of different modulation types with high accuracy under the condition of a low SNR.


Assuntos
Aprendizado Profundo , Razão Sinal-Ruído , Ruído
11.
Sensors (Basel) ; 21(3)2021 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-33572805

RESUMO

Dual-comb spectroscopy has been an infusive spectroscopic tool for gas detection due to its high resolution, high sensitivity, and fast acquisition speed over a broad spectral range without any mechanical scanning components. However, the complexity and cost of high-performance dual-comb spectroscopy are still high for field-deployed applications. To solve this problem, we propose a simple frequency domain post-processing method by extracting the accurate position of a specific absorption line frame by frame. After aligning real-time spectra and averaging for one second, the absorbance spectrum of H13C14N gas in the near-infrared is obtained over 1.1 THz spectral range. By using this method, the standard deviation of residual error is only ~0.002, showing great agreement with the conventional correction method. In addition, the spectral resolution is improved from 13.4 GHz to 4.3 GHz compared to direct spectrum averaging. Our method does not require a specially designed common-mode suppression comb, rigorous frequency control system, or complicated computational algorithm, providing a cost-effective scheme for field-deployed Doppler-limited spectroscopy applications.

12.
Sensors (Basel) ; 21(7)2021 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-33917589

RESUMO

A capacitive measurement of the biosignals is a very comfortable and unobtrusive way suitable for long-term and wearable monitoring of health conditions. This type of sensing is very susceptible to noise from the surroundings. One of the main noise sources is power-line noise, which acts as a common-mode voltage at the input terminals of the acquisition unit. The origin and methods of noise reduction are described on electric models. Two methods of noise removal are modeled and experimentally verified in the paper. The first method uses a passive capacitive grounding electrode, and the second uses an active capacitive Driven Right Leg (DRL) electrode. The effect of grounding electrode size on noise suppression is experimentally investigated. The increasing electrode area reduces power-line noise: the power of power-line frequency within the measured signal is 70.96 dB, 59.13 dB, and 43.44 dB for a grounding electrode area of 1650 cm2, 3300 cm2, and 4950 cm2, respectively. The capacitive DRL electrode shows better efficiency in common-mode noise rejection than the grounding electrode. When using an electrode area of 1650 cm2, the DRL achieved 46.3 dB better attenuation than the grounding electrode at power-line frequency. In contrast to the grounding electrode, the DRL electrode reduces a capacitive measurement system's financial costs due to the smaller electrode area made of the costly conductive textile.

13.
Sensors (Basel) ; 21(20)2021 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-34695930

RESUMO

Sound event detection (SED) recognizes the corresponding sound event of an incoming signal and estimates its temporal boundary. Although SED has been recently developed and used in various fields, achieving noise-robust SED in a real environment is typically challenging owing to the performance degradation due to ambient noise. In this paper, we propose combining a pretrained time-domain speech-separation-based noise suppression network (NS) and a pretrained classification network to improve the SED performance in real noisy environments. We use group communication with a context codec method (GC3)-equipped temporal convolutional network (TCN) for the noise suppression model and a convolutional recurrent neural network for the SED model. The former significantly reduce the model complexity while maintaining the same TCN module and performance as a fully convolutional time-domain audio separation network (Conv-TasNet). We also do not update the weights of some layers (i.e., freeze) in the joint fine-tuning process and add an attention module in the SED model to further improve the performance and prevent overfitting. We evaluate our proposed method using both simulation and real recorded datasets. The experimental results show that our method improves the classification performance in a noisy environment under various signal-to-noise-ratio conditions.


Assuntos
Redes Neurais de Computação , Ruído , Razão Sinal-Ruído , Som , Fala
14.
Sensors (Basel) ; 21(15)2021 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-34372256

RESUMO

For subjects with amyotrophic lateral sclerosis (ALS), the verbal and nonverbal communication is greatly impaired. Steady state visually evoked potential (SSVEP)-based brain computer interfaces (BCIs) is one of successful alternative augmentative communications to help subjects with ALS communicate with others or devices. For practical applications, the performance of SSVEP-based BCIs is severely reduced by the effects of noises. Therefore, developing robust SSVEP-based BCIs is very important to help subjects communicate with others or devices. In this study, a noise suppression-based feature extraction and deep neural network are proposed to develop a robust SSVEP-based BCI. To suppress the effects of noises, a denoising autoencoder is proposed to extract the denoising features. To obtain an acceptable recognition result for practical applications, the deep neural network is used to find the decision results of SSVEP-based BCIs. The experimental results showed that the proposed approaches can effectively suppress the effects of noises and the performance of SSVEP-based BCIs can be greatly improved. Besides, the deep neural network outperforms other approaches. Therefore, the proposed robust SSVEP-based BCI is very useful for practical applications.


Assuntos
Interfaces Cérebro-Computador , Eletroencefalografia , Potenciais Evocados , Potenciais Evocados Visuais , Humanos , Estimulação Luminosa
15.
J Struct Biol ; 211(2): 107545, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32534144

RESUMO

Single particle analysis has become a key structural biology technique. Experimental images are extremely noisy, and during iterative refinement it is possible to stably incorporate noise into the reconstruction. Such "over-fitting" can lead to misinterpretation of the structure and flawed biological results. Several strategies are routinely used to prevent over-fitting, the most common being independent refinement of two sides of a split dataset. In this study, we show that over-fitting remains an issue within regions of low local signal-to-noise, despite independent refinement of half datasets. We propose a modification of the refinement process through the application of a local signal-to-noise filter: SIDESPLITTER. We show that our approach can reduce over-fitting for both idealised and experimental data while maintaining independence between the two sides of a split refinement. SIDESPLITTER refinement leads to improved density, and can also lead to improvement of the final resolution in extreme cases where datasets are prone to severe over-fitting, such as small membrane proteins.


Assuntos
Imageamento Tridimensional , Proteínas de Membrana/ultraestrutura , Modelos Moleculares , Imagem Individual de Molécula/métodos , Algoritmos , Proteínas de Membrana/química , Razão Sinal-Ruído , Software
16.
Sensors (Basel) ; 20(19)2020 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-33023210

RESUMO

An external modulation laser module assembly (EMLMA) is proposed to suppress nonlinear errors in an interferometry system and improve its measurement performance. The EMLMA employs both phase modulation with radio frequency signal and a specific modulation amplitude switching mode, enabling the suppression of noise introduced by spurious reflections. The amplitude modulation reduces the influence of stray and background light by transforming the signal of interest to a high-frequency bandwidth. Experimental results show that the measurement error and stability of the interferometry system are significantly improved using the proposed light source module. After modulation, the spurious reflection-induced offset is decreased, and the measurement resolution improves from 7 to 2 nm. The EMLMA can replace the light source of any interferometric measurement system without altering the optical measurement structure. The proposed method reduces the influence of nonlinear errors in homodyne interferometry and provides a basis for further improvement of the interferometry performance.

17.
Sensors (Basel) ; 20(18)2020 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-32961880

RESUMO

Compressive single-pixel imaging (CSPI) is a novel imaging scheme that retrieves images with nonpixelated detection. It has been studied intensively for its minimum requirement of detector resolution and capacity to reconstruct image with underdetermined acquisition. In practice, CSPI is inevitably involved with noise. It is thus essential to understand how noise affects its imaging process, and more importantly, to develop effective strategies for noise compression. In this work, two ypes of noise classified as multiplicative and additive noises are discussed. A normalized compressive reconstruction scheme is firstly proposed to counteract multiplicative noise. For additive noise, two types of compressive algorithms are studied. We find that pseudo-inverse operation could render worse reconstructions with more samplings in compressive sensing. This problem is then solved by introducing zero-mean inverse measurement matrix. Both experiment and simulation results show that our proposed algorithms significantly surpass traditional methods. Our study is believed to be helpful in not only CSPI but also other denoising works when compressive sensing is applied.

18.
Sensors (Basel) ; 20(22)2020 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-33203043

RESUMO

In this paper, we propose a multi-channel cross-tower with attention mechanisms in latent domain network (Multi-TALK) that suppresses both the acoustic echo and background noise. The proposed approach consists of the cross-tower network, a parallel encoder with an auxiliary encoder, and a decoder. For the multi-channel processing, a parallel encoder is used to extract latent features of each microphone, and the latent features including the spatial information are compressed by a 1D convolution operation. In addition, the latent features of the far-end are extracted by the auxiliary encoder, and they are effectively provided to the cross-tower network by using the attention mechanism. The cross tower network iteratively estimates the latent features of acoustic echo and background noise in each tower. To improve the performance at each iteration, the outputs of each tower are transmitted as the input for the next iteration of the neighboring tower. Before passing through the decoder, to estimate the near-end speech, attention mechanisms are further applied to remove the estimated acoustic echo and background noise from the compressed mixture to prevent speech distortion by over-suppression. Compared to the conventional algorithms, the proposed algorithm effectively suppresses the acoustic echo and background noise and significantly lowers the speech distortion.

19.
Sensors (Basel) ; 20(8)2020 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-32331326

RESUMO

This article introduces a two-electrode ground-free electrocardiogram (ECG) with minimal hardware complexity, which is ideal for wearable battery-powered devices. The main issue of ground-free measurements is the presence of noise. Therefore, noise suppression methods that can be employed for a two-electrode ECG acquisition system are discussed in detail. Experimental measurements of a living subject and patient simulator are used to investigate and compare the performance of the three proposed methods utilizing the ADS1191 analogue front-end for biopotential measurements. The resulting signals recorded for the simulator indicate that all three methods should be suitable for suppressing power-line noise. The Power Spectral Density (PSD) of the signals measured for a subject exhibits differences across methods; the signal power at 50 Hz is -28, -24.8, and -26 dB for the first, second, and third method, respectively. The digital postprocessing of measured signals acquired a high-quality ECG signal comparable to that of three-electrode sensing. The current consumption measurements demonstrate that all proposed two-electrode ECG solutions are appropriate as a battery-powered device (current consumption < 1.5 mA; sampling rate of 500 SPS). The first method, according to the results, is considered the most effective method in the suppression of power-line noise, current consumption, and hardware complexity.


Assuntos
Eletrocardiografia/métodos , Eletrodos , Algoritmos , Humanos , Dispositivos Eletrônicos Vestíveis
20.
Sensors (Basel) ; 20(4)2020 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-32085651

RESUMO

A high-precision acceleration measurement system based on an ultra-sensitive tunnel magneto-resistance (TMR) sensor is presented in this paper. A "force-magnetic-electric" coupling structure that converts an input acceleration into a change in magnetic field around the TMR sensor is designed. In such a structure, a micro-cantilever is integrated with a magnetic field source on its tip. Under an acceleration, the mechanical displacement of the cantilever causes a change in the spatial magnetic field sensed by the TMR sensor. The TMR sensor is constructed with a Wheatstone bridge structure to achieve an enhanced sensitivity. Meanwhile, a low-noise differential circuit is developed for the proposed system to further improve the precision of the measured acceleration. The experimental results show that the micro-system achieves a measurement resolution of 19 µg/√Hz at 1 Hz, a scale factor of 191 mV/g within a range of ± 2 g, and a bias instability of 38 µg (Allan variance). The noise sources of the proposed system are thoroughly investigated, which shows that low-frequency 1/f noise is the dominant noise source. We propose to use a high-frequency modulation technique to suppress the 1/f noise effectively. Measurement results show that the 1/f noise is suppressed about 8.6-fold at 1 Hz and the proposed system resolution can be improved to 2.2 µg/√Hz theoretically with this high-frequency modulation technique.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA