Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Environ Res ; 251(Pt 2): 118762, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38527720

RESUMO

Treating high salt and high organic matter wastewater (HHW) generated during rapid socio-economic development is a significant challenge. This study aims to optimize a closed-cycle low-temperature evaporation (CCLE) system using mathematical modelling to be adapted to industrial applications. By using mathematical modelling and computational fluid dynamics (CFD), this study investigated the operating mechanism of the system under different operating conditions. Parametric analysis shows that increasing the compressor evaporation temperature and decreasing the condensation temperature is conducive to improving the performance of the heat pump unit, thereby increasing the wastewater treatment efficiency of the system and that a smaller heat transfer coil windward area is conducive to heat and mass transfer within the humidifier. The unique characteristics of the CCLE system are identified, and the wastewater treatment process under various operating conditions is explained. These findings may provide supporting information for the treatment of HHW by the CCLE system.


Assuntos
Hidrodinâmica , Modelos Teóricos , Eliminação de Resíduos Líquidos/métodos , Águas Residuárias/química , Temperatura Baixa
2.
Sensors (Basel) ; 24(8)2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38676120

RESUMO

Concrete-filled steel tube (CFST) members have been widely used in civil engineering due to their advanced mechanical properties. However, internal defects such as the concrete core voids and interface debonding in CFST structures are likely to weaken their load-carrying capacity and stiffness, which affects the safety and serviceability. Visualizing the inner defects of the concrete cores in CFST members is a critical requirement and a challenging task due to the obvious difference in the material mechanical parameters of the concrete core and steel tube in CFST members. In this study, a curved ray theory-based travel time tomography (TTT) with a least square iterative linear inversion algorithm is first introduced to quantitatively identify and visualize the sizes and positions of the concrete core voids in CFST members. Secondly, a numerical investigation of the influence of different parameters on the inversion algorithm for the defect imaging of CFST members, including the effects of the model weighting matrix, weighting factor and grid size on the void's imaging quality and accuracy, is carried out. Finally, an experimental study on six CFST specimens with mimicked concrete core void defects is performed in a laboratory and the mimicked defects are visualized. The results demonstrate that TTT can identify the sizes and positions of the concrete core void defects in CFST members efficiently with the use of optimal parameters.

3.
Entropy (Basel) ; 24(2)2022 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-35205589

RESUMO

As computational fluid dynamics (CFD) advances, entropy generation minimization based on CFD becomes attractive for optimizing complex heat-transfer systems. This optimization depends on the accuracy of CFD results, such that accurate turbulence models, such as elliptic relaxation or elliptic blending turbulence models, become important. The performance of a previously developed elliptic blending turbulence model (the SST k-ω-φ-α model) to predict the rate of entropy generation in the fully developed turbulent circular tube flow with constant heat flux was studied to provide some guidelines for using this class of turbulence model to calculate entropy generation in complex systems. The flow and temperature fields were simulated by using a CFD package, and then the rate of entropy generation was calculated in post-processing. The analytical correlations and results of two popular turbulence models (the realizable k-ε and the shear stress transport (SST) k-ω models) were used as references to demonstrate the accuracy of the SST k-ω-φ-α model. The findings indicate that the turbulent Prandtl number (Prt) influences the entropy generation rate due to heat-transfer irreversibility. Prt = 0.85 produces the best results for the SST k-ω-φ-α model. For the realizable k-ε and SST k-ω models, Prt = 0.85 and Prt = 0.92 produce the best results, respectively. For the realizable k-ε and the SST k-ω models, the two methods used to predict the rate of entropy generation due to friction irreversibility produce the same results. However, for the SST k-ω-φ-α model, the rates of entropy generation due to friction irreversibility predicted by the two methods are different. The difference at a Reynolds number of 100,000 is about 14%. The method that incorporates the effective turbulent viscosity should be used to predict the rate of entropy generation due to friction irreversibility for the SST k-ω-φ-α model. Furthermore, when the temperature in the flow field changes dramatically, the temperature-dependent fluid properties must be considered.

4.
Entropy (Basel) ; 24(11)2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36359639

RESUMO

Energy-saving roof renovation methods are effective ways to alleviate the urban heat island effect. In this paper, the authors propose three models of two-layer water-retained bricks, established the physical and mathematic models of the water-retained bricks, and then conducted a computational fluid dynamics (CFD) simulation on the effect of wind speed and evaporation space height on the water-evaporating performance of water-retained bricks. The results show that: (1) for the water-retained bricks with no-hole lids, macroscopic evaporation does not happen under the static wind conditions; with the increase of wind speed, the evaporating boundary layer thickness decreases, the water vapor concentration gradient in the boundary layer and the mass diffusion flux increase; (2) for the water-retained bricks with strip-hole lids, under the static wind condition, the evaporating performance of the water-retained bricks with strip-hole lids is better than that of bricks with no-hole lids; with the increase of wind speed, the evaporation of bricks with strip-hole lids is less affected by inlet airflow velocity than that of bricks with no-hole lids; (3) as for both the water-retained bricks with no-hole lids and with strip-hole lids, for a given wind speed, both the water vapor concentration gradient and the mass diffusion flux decrease as the evaporation space increases.

5.
Electrophoresis ; 41(10-11): 811-820, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32097991

RESUMO

Ion concentration polarization (ICP) imposes remarkable adverse effects on the energy conversion performance of the pressure-driven electrokinetic (EK) flows through a capillary system that can be equivalently treated as a battery. An optimized dimensionless numerical method is proposed in this study to investigate the causes and the effects of the ICP. Results show that remarkable ICP phenomena are induced under certain conditions such as high applied pressure, high surface charge density, and small inversed Debye length at dimensionless values of 6000, -10, and 0.5. Meanwhile, different factors influence the ICP and the corresponding electric properties in different ways. Particularly for the overall electric resistance, the applied pressure and the surface charge density mainly affect the variation amplitude and the level of the overall electric resistance when varying the output electric potential, respectively. Differently, the Debye length affects the overall electric resistance in both aspects. Ultimately, the induced ICP leads to significant nonlinear current-potential curves.


Assuntos
Fontes de Energia Elétrica , Técnicas Eletroquímicas/instrumentação , Desenho de Equipamento , Íons/química , Dinâmica não Linear
6.
Geophys Prospect ; 68(5): 1425-1442, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32612295

RESUMO

Acoustic inversion in one-dimension gives impedance as a function of travel time. Inverting the reflection response is a linear problem. Recursive methods, from top to bottom or vice versa, are known and use a fundamental wave field that is computed from the reflection response. An integral over the solution to the Marchenko equation, on the other hand, retrieves the impedance at any vertical travel time instant. It is a non-recursive method, but requires the zero-frequency value of the reflection response. These methods use the same fundamental wave field in different ways. Combining the two methods leads to a non-recursive scheme that works with finite-frequency bandwidth. This can be used for target-oriented inversion. When a reflection response is available along a line over a horizontally layered medium, the thickness and wave velocity of any layer can be obtained together with the velocity of an adjacent layer and the density ratio of the two layers. Statistical analysis over 1000 noise realizations shows that the forward recursive method and the Marchenko-type method perform well on computed noisy data.

7.
Electrophoresis ; 40(5): 699-709, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30168150

RESUMO

The electrophoresis of a polyelectrolyte nanoparticle, whose charge condition depends on the salt concentration and pH of the suspended medium as well as the dielectric permittivity difference, is analyzed. The present nonlinear model for the electrophoresis of this pH-regulated polyelectrolyte (PE) particle is based on the consideration of full set of governing equations of fluid and ion transport coupled with the equation for electric field. The Born energy of the ions are incorporated to account for the difference in the dielectric permittivity of the PE and the electrolyte. The governing equations are computed numerically through a control volume approach. The nonlinear effects are highlighted by comparing with the existing linear model as well as results based on the first-order perturbation analysis valid for a weak applied field. The ion partitioning effect arising due to the difference in self energy of ions between the two media, have a strong impact on the mobility of the PE. The ion partitioning effect attenuates the penetration of counterions in the PE, which enhances the electric force and hence, results in a larger mobility of the PE. The nonlinear effects due to the double layer polarization and relaxation are intensified due to the ion partitioning effect. The ion partitioning effect influences the association/dissociation of PE functional group by tuning the hydrogen/hydroxide ions. Present study shows that the ion partitioning effect is profound for higher salt concentration and/or higher volume density of PE functional groups.


Assuntos
Eletroforese/métodos , Íons/isolamento & purificação , Nanogéis/química , Concentração de Íons de Hidrogênio , Íons/análise , Íons/química , Polieletrólitos/química
8.
Entropy (Basel) ; 21(3)2019 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-33266948

RESUMO

Organic semi-conductors have unique electronic properties and are important systems both at the fundamental level and also for their applications in electronic devices. In this article we focus on the particular case of rubrene which has one of the best electronic transport properties for application purposes. We show that this system can be well simulated by simple tight-binding systems representing one-dimensional (1D) chains that are weakly coupled to their neighboring chains in the same plane. This makes in principle this rubrene system somehow intermediate between 1D and isotropic 2D models. We analyse in detail the dc-transport and terahertz conductivity in the 1D and in the anisotropic 2D models. The transient localisation scenario allows us to reproduce satisfactorily some basics results such as mobility anisotropy and orders of magnitude as well as ac-conductivity in the terahertz range. This model shows in particular that even a weak inter-chain coupling is able to improve notably the propagation along the chains. This suggest also that a strong inter-chain coupling is important to get organic semi-conductors with the best possible transport properties for applicative purposes.

9.
Eur Biophys J ; 46(8): 705-718, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28488019

RESUMO

Biological membranes are composed of different components and there is no a priori reason to assume that all components are isotropic. It was previously shown that the anisotropic properties of membrane components may explain the stability of membrane tubular protrusions even without the application of external force. Our theoretical study focuses on the role of anisotropic membrane components in the stability of membrane tubular structures generated or stabilized by actin filaments. We show that the growth of the actin cytoskeleton inside the vesicle can induce the partial lateral segregation of different membrane components. The entropy of mixing of membrane components hinders the total lateral segregation of the anisotropic and isotropic membrane components. Self-assembled aggregates formed by anisotropic membrane components facilitate the growth of long membrane tubular protrusions. Protrusive force generated by actin filaments favors strong segregation of membrane components by diminishing the opposing effect of mixing entropy.


Assuntos
Citoesqueleto de Actina/metabolismo , Membrana Celular/metabolismo , Extensões da Superfície Celular/metabolismo , Fenômenos Mecânicos , Modelos Biológicos , Anisotropia , Fenômenos Biomecânicos , Método de Monte Carlo
10.
Int J Numer Method Biomed Eng ; 40(5): e3812, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38544307

RESUMO

The lack of in vivo studies on the delivery of doxorubicin within human skin, especially the absence of data on the doxorubicin diffusion coefficient, has made understanding its transdermal delivery kinetics challenging. In this study, as a first step, governing equations and finite element methods were employed to reproduce Franz diffusion cell experiment in human cadaver skin. The application of this experiment representative model with a fitting method resulted in approximate values for the diffusivity of doxorubicin across various skin layers. The estimated values were used later to conduct a comprehensive examination of doxorubicin administration for breast tumor treatments. In a 2D axisymmetric model using Fick's Law and then a microneedles array 3D model, crucial parameters effects on delivery efficiency were examined, such as the microneedle tip diameter, tip-to-tip distance, and tumor depth. As highlighted by the findings of this study, these parameters have an impact on the effectiveness of doxorubicin delivery for treating breast tumors. The focus of this research is on the potential of numerical methods in biomedical engineering, which addresses the urgent need for data on doxorubicin diffusion in human skin and offers valuable insights into optimizing drug delivery strategies for enhanced therapeutic outcomes.


Assuntos
Administração Cutânea , Neoplasias da Mama , Doxorrubicina , Sistemas de Liberação de Medicamentos , Agulhas , Doxorrubicina/administração & dosagem , Doxorrubicina/farmacocinética , Humanos , Neoplasias da Mama/tratamento farmacológico , Feminino , Análise de Elementos Finitos , Pele/metabolismo , Modelos Biológicos , Difusão
11.
Materials (Basel) ; 17(14)2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-39063698

RESUMO

This study is focused on the application of 3D-printed elements and conventional elements to create a prototype of a custom-made exoskeleton for lower limb rehabilitation. The 3D-printed elements were produced by using Fused Deposition Modeling technology and acrylonitrile butadiene styrene (ABS) material. The scope of this work involved the design and construction of an exoskeleton, experimental testing of the ABS material and numerical research by using the finite element method. On the basis of the obtained results, it was possible to deduce whether the load-bearing 3D-printed elements can be used in the proposed mechanical construction. The work contains full data of the material models used in FEM modeling, taking into account the orthotropic properties of the ABS material. Various types of finite elements were used in the presented FE models. The work is a comprehensive combination of material testing issues with the possibility of implementing the obtained results in numerical strength models of machine parts.

12.
Micromachines (Basel) ; 15(6)2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38930665

RESUMO

Bubble flow in confined geometries is a problem of fundamental and technological significance. Among all the forms, bubble breakup in bifurcated microchannels is one of the most commonly encountered scenarios, where an in-depth understanding is necessary for better leveraging the process. This study numerically investigates the non-uniform breakup of a bubble slug in Y-shaped microchannels under different flow ratios, Reynolds numbers, and initial bubble volumes. Overall, the bubble can either breakup or non-breakup when passing through the bifurcation and shows different forms depending on flow regimes. The flow ratio-Reynolds number phase diagrams indicate a power-law transition line of breakup and non-breakup. The bubble takes longer to break up with rising flow ratios yet breaks earlier with higher Reynolds numbers and volumes. Non-breakup takes less time than the breakup patterns. Flow ratio is the origin of non-uniform breakup. Both the Reynolds number and initial volume influence the bubble states when reaching the bifurcation and thus affect subsequent processes. Bubble neck dynamics are analyzed to describe the breakup further. The volume distribution after breaking up is found to have a quadratic relation with the flow ratio. Our study is hoped to provide insights for practical applications related to non-uniform bubble breakups.

13.
Heliyon ; 10(5): e27236, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38486763

RESUMO

Researchers have extensively explored various approaches to enhance the blast resistance of structures, concentrating on optimizing structural designs and employing a wide range of materials. This research investigates the impact of incorporating water as a fluid within the core of tubular sandwich panels on blast mitigation effectiveness. The study systematically analyzes various panel configurations by altering key design parameters: the thickness of the face sheets, spacing between the core elements, and proportion of fluid within the core. These variables are scrutinized through metrics such as elastic strain energy, the amount of work applied externally, and the movement of the panel. Utilizing finite element analysis, 27 distinct numerical experiments were conducted to gather data. The findings demonstrate that panels with a water-filled core exhibit superior blast resistance compared to their non-fluid counterparts. Specifically, panels with completely filled cores showed the lowest levels of panel displacement and external work, whereas those with half-filled cores recorded the highest elastic strain energy. Furthermore, regression analysis revealed that plate thickness predominantly influences panel displacement and external work, whereas the fluid volume fraction within the core most significantly affects elastic strain energy. This study contributes to the understanding of fluid-structure interactions in blast-resistant design, offering valuable insights for optimizing structural defenses against blast impacts.

14.
Biomed Phys Eng Express ; 10(3)2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38447212

RESUMO

The analysis of degradation in the presence of cell death and migration is a critical aspect of research in various biological fields, such as tissue engineering, regenerative medicine, and disease pathology. In present study, numerical study of degradation of scaffold were performed in present of cells, cell apoptosis and cell migration. A poly electrolyte complex (PEC) silk fibroin scaffold was used for degradation study. Degradation study in the presence of cells and migration were performed at fixed pH concentration 7.2. Similarly, degradation study of scaffold were performed at different pH cell apoptosis. A transient analysis of scaffold was evaluated in COMSOL 5.5 in presence of cryogenic temperature at different temperature gradient. The parameters; temperature, stress, strain tensor and deformation gradient associated with the degradation of polyelectrolyte complex scaffold were evaluated. Result shows that in both geometries minimum temperature had been achieved as 230.051 K at point P4 in series view and parallel view and at a point P3 for cell migration study for -5 k min-1and -1 k min-1, respectively. The maximum stress had been generated for 5.57 × 107N m-2for the temperature gradient of -2 K min-1at T cycle in the case of cell migration study. In contrast in series view the maximum stress 2.9 × 107 N m-2were observed at P4 which was higher as compare to P3. Similarly, for a parallel view, maximum stress (3.93 × 107 N m-2) was obtained for point P3. It had been observed that the maximum strain tensor 5.21 × 10-3, 5.15 × 10-3and 5.26 × 10-3was generated in series view at 230 k on a point P3 for - 1, -2 and -5 K min-1, respectively. Similarly, the maximum strain tensor 8.16 × 10-3, 8.09 × 10-3and 8.09 × 10-3was generated in parallel view at 230 k on a point P3 for -1, -2 and -5 K min-1, respectively. In the presence of cells, at a point P4 for temperature gradient of -1 and -2 K min-1, it had been closed to the scaffold wall, which had a different temperature profile than the point P3 and scaffold comes to the contact with the cells. The analysis of PEC scaffold degradation in the presence of cells, including cell apoptosis and migration, offers significant insights into the relationship between scaffold properties, cell behaviour, and tissue regeneration.


Assuntos
Fibroínas , Alicerces Teciduais , Alicerces Teciduais/química , Engenharia Tecidual/métodos , Fibroínas/química , Apoptose , Movimento Celular
15.
Materials (Basel) ; 17(12)2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38930264

RESUMO

In order to study the bending-shear performance of CFRP concrete-filled steel tubes, static tests were conducted on 15 circular concrete-filled CFRP steel tube bending-shear specimens. For all specimens, Ds was 120 mm, ts was 2 mm, and ml was 1. The shear displacement (V-Δ) curve of the specimen and the collaborative work between the steel tube and CFRP are discussed. ABAQUS was applied to simulate the V-Δ curve and failure mode of the specimen. We explored the effects of CFRP layers, material strength, the steel ratio, and the shear span ratio on the bending-shear performance of components. The experimental results show that a steel tube and CFRP can work together. As the shear span ratio increased, the bearing capacity and stiffness of the specimen decreased. An increase in the number of transverse CFRP layers could improve the bearing capacity of the specimen, but it had no significant effect on the stiffness. Calculating the elastic stage stiffness and bearing capacity of 15 short columns of test and FE curves revealed an average error of 6.71% and a mean square error of 0.83 for the elastic stage stiffness. The simulation results of the established finite element model are in good agreement with the experimental results. The average error of the bearing capacity was 3.88%, with a mean square error of 0.94. Based on experimental and finite element results, the moment shear correlation equation for concrete-filled CFRP steel tube bending-shear members is presented.

16.
Materials (Basel) ; 16(12)2023 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-37374439

RESUMO

Based on the analysis of existing collective shockwave protection methods worldwide, this paper addresses the mitigation of shock waves by means of passive methods, namely the use of perforated plates. Employing specialized software for numerical analysis, such as ANSYS-AUTODYN 2022R1®, the interaction of shock waves with a protection structure has been studied. By using this cost-free approach, several configurations with different opening ratios were investigated, pointing out the peculiarities of the real phenomenon. The FEM-based numerical model was calibrated by employing live explosive tests. The experimental assessments were performed for two configurations, with and without a perforated plate. The numerical results were expressed in terms of force acting on an armor plate placed behind a perforated plate at a relevant distance for ballistic protection in engineering applications. By investigating the force/impulse acting on a witness plate instead of the pressure measured at a single point, a realistic scenario can be considered. For the total impulse attenuation factor, the numerical results suggest a power law dependence, with the opening ratio as a variable.

17.
Artigo em Inglês | MEDLINE | ID: mdl-37950444

RESUMO

The mortality rates due to cardiovascular diseases are on a rise globally. One of the major cardiovascular diseases is stroke which occurs due to atherosclerotic plaques build-up in the carotid artery. The common carotid artery (CCA) bifurcates into the internal carotid artery (ICA) and external carotid artery (ECA). Sinus present at ICA is an ellipsoidal-shaped dilated region acting as a pressure receptor and blood flow regulator. Dimensions of the sinus vary from person to person, affecting the hemodynamics of the carotid artery. The current numerical study manifests a 3D flow analysis by varying the sinus length to investigate its local and global effects on the hemodynamics of the carotid artery using various biomechanical risk analysis parameters of atherosclerosis. User-defined function (UDF) dictates the pulsatile flow velocity profile imposed at the inlet. Near the outer wall (OW) of the sinus, the blood flow velocities are lower and recirculation zones are more. Though the recirculation zones for shorter sinus will be close to the inner wall (IW), interestingly, with an increase in the sinus length, the recirculation zones shift toward the OW with higher strength. These significantly decrease the x-wall shear stress (x-WSS) and time-averaged wall shear stress (TAWSS) values on the OW of the longer sinus. The other risk analysis parameters, like oscillatory shear index (OSI) and relative residence time (RRT), support the described consequences. These results reveal that sinus of increased length is more prone to developing atherosclerotic plaque.

18.
Heliyon ; 9(3): e14438, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36950573

RESUMO

Transition metal di-chalcogenides (TMCDs)-Tungsten disulfide (WS2) exhibit excellent optoelectronic properties such as suitable bandgap, high absorption coefficient, good conductivity, high carrier mobility, etc. to be used as a photovoltaic material for thin-film solar cells. In the present work, we have replaced the traditional buffer CdS and ITO/ZnO window layer in CdTe solar cells with the non-toxic, earth-abundant WS2 buffer and SnO2 window layer, respectively. The SCAPS-1D solar simulator is used to investigate the potentiality of WS2 as buffer material in CdTe solar cells. This numerical study provides a comparison of the performances between the proposed structure: SnO2/WS2/CdTe/Au and the baseline structure: ITO/ZnO/CdS/CdTe/Au. The impacts of the charge carrier generation rate, spectral response, current-voltage characteristics, bulk defect density, defect density at buffer/absorber interface, operating temperature, and capacitance-voltage characteristics on the solar cell performance parameters have also been analyzed. The tolerance level of defect density in WS2 bulk and WS2/CdTe interface are found to be 1017 cm-3 and 1012 cm-3, respectively. The temperature study reveals the poor structural robustness and thermal stability of the proposed cell. The conversion efficiency of the proposed cell has found to be 20.55% at the optimized device structure. Nevertheles, these findings may provide an insight to fabricate viable, environment friendly, and inexpensive CdTe thin-film solar cells.

19.
Materials (Basel) ; 16(8)2023 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-37110101

RESUMO

A hybrid girder bridge adopts a steel segment at the mid-span of the main span of a continuous concrete girder bridge. The critical point of the hybrid solution is the transition zone, connecting the steel and concrete segments of the beam. Although many girder tests revealing the structural behavior of hybrid girders have been conducted by previous studies, few specimens took the full section of a steel-concrete joint due to the large size of prototype hybrid bridges. In this study, a static load test on a composite segment to bridge the joint between the concrete and steel parts of a hybrid bridge with full section was conducted. A finite element model replicating the tested specimen results was established through Abaqus, while parametric studies were also conducted. The test and numerical results revealed that the concrete filling in the composite solution prevented the steel flange from extensive buckling, which significantly improved the load-carrying capacity of the steel-concrete joint. Meanwhile, strengthening the interaction between the steel and concrete helps to prevent the interlayer slip and simultaneously contributes to a higher flexural stiffness. These results are an important basis for establishing a rational design scheme for the steel-concrete joint of hybrid girder bridges.

20.
Comput Biol Med ; 159: 106842, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37062254

RESUMO

OBJECTIVE: Hemolysis performance is a crucial criterion for roller pumps utilized in life supporting system. In this study, the factor of hemolysis for roller pumps was selected as the target, and an estimation formulation was built to evaluate its hemolysis. METHODS: Several models were proposed and then simulated with the assistant of Computational fluid dynamics (CFD) framework. The hemolysis performance was calculated using the power law model based on CFD and the estimation model in accordance with geometry parameters proposed in this study. The results of the in vitro experiments were compared with the simulation results. Power law model with the lowest error was utilized in following analysis. RESULTS: As indicated by the simulation result, the rotary speed most significantly affected the hemolysis performance of roller blood pumps, followed by roller number and diameter of tube. The index of hemolysis (IH) for roller blood pumps at a rotary speed of 20-100 rpm ranged from 8.73E-7 to 8.07E-5. The relative error of the estimation model (4.93%) was lower than of the power law model (6.78%). CONCLUSION: The IH led by pumps shows a significant, nonlinear relationship with the rotary speed. The design of multiple rollers design is harmful for hemolysis performance and larger diameter of tube exhibits decreased hemolysis at constant flow rate. An estimation formula was proposed with lower relative error for roller pump with the same shell set, which exhibited reduced computation and elevated convenience. And it can be utilized in hemolysis estimation of roller pumps potentially.


Assuntos
Coração Auxiliar , Hemólise , Humanos , Desenho de Equipamento , Hidrodinâmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA